データシート

For more information, please visit the product page.
date
12/12/2014
page
1 of 7
SERIES: PSF-155 │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
up to 155 W continuous power
universal input (90~264 Vac)
built-in constant current limit circuitry
alarm signal for AC OK and battery low
short circuit, over load, over voltage, brown-out,
battery low, and battery polarity protections
• withstand 2G vibration test
• efficiency up to 86%
MODEL
output
voltage
output
current1
output
power2
ripple
and noise3
efficiency
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
PSF-155-A
Vo1
Vo2
13.8
13.8
11.2
3.88
155
100
150
86
PSF-155-B
Vo1
Vo2
Vo3
13.8
13.8
5
10.1
3.88
3
155
100
150
100
85
PSF-155-C
Vo1
Vo2
27.6
27.6
5.6
2.1
155
100
150
86
PSF-155-D
Vo1
Vo2
Vo3
27.6
27.6
5
5.1
2.1
3
155
100
150
100
85
Notes:
1. Vo2 battery discharge current must not exceed 40% of the rated power.
2. Maximum total combined power (rated power).
3. At 20 MHz bandwidth using a 12” twisted pair-wire, each output terminated with a 47 µF and 0.1 µF parallel capacitors.
PART NUMBER KEY
PSF-155 - X - XXX
Base Number
Output Voltage
A = 13.8 Vdc, 13.8 Vdc
B = 13.8 Vdc, 13.8 Vdc, 5 Vdc
C = 27.6 Vdc, 27.6 Vdc
D = 27.6 Vdc, 27.6 Vdc, 5 Vdc
cui.com
Chassis
CNF = enclosed
CF = enclosed with fan
For more information, please visit the product page.
CUI Inc │ SERIES: PSF-155 │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/12/2014
page 2 of 7
INPUT
parameter
conditions/description
min
typ
90
127
voltage
surge voltage
for maximum of 5 seconds
frequency
47
max
units
264
373
Vac
Vdc
300
Vac
63
Hz
current
at 115 Vac
at 230 Vac
2.5
1.5
A
A
inrush current
at 115 Vac, cold start
at 230 Vac, cold start
55
108
A
A
leakage current
at 264 Vac
power factor
at full load
0.94
parameter
conditions/description
min
line regulation
low line to high line, at rated load
Vo1, Vo3
±0.5
%
load regulation
10% to 100% rated load
Vo1
Vo3
±0.5
±1.5
%
%
voltage accuracy
Vo1
Vo3
±2
±3
%
%
hold-up time
at 115/230 Vac, full load
30
ms
setup time
at 115 Vac, full load, cold start
at 230 Vac, full load, cold start
rise time
at 115/230 Vac, full load
adjustability
Vo1
temperature coefficient
Vo1, 0°C~50°C
AC OK
PSF-155-A, PSF-155-C
PSF-155-B, PSF-155-D
TTL open collector output
relay contact output
battery low
PSF-155-A, PSF-155-B
PSF-155-C, PSF-155-D
<12 V ±3%
<22 V ±3%
1
mA
max
units
OUTPUT
typ
3200
2400
ms
ms
20
ms
±10
%
±0.03
%/°C
PROTECTIONS
parameter
conditions/description
min
typ
max
units
over voltage protection
Vo1, latch off mode
115
over current protection
auto recovery, hiccup mode
Vo1, Vo3
Vo2
150
%
110
100
battery cut off
PSF-155-A, PSF-155-B
PSF-155-C, PSF-155-D
9.6
19
10
20
10.4
21
Vdc
Vdc
min
typ
max
units
%
%
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
input to output
input to ground
output to ground
isolation resistance
input to output at 500 Vdc
safety approvals
UL 60950-1, EN 60950-1
EMI/EMC1
EN 55022, EN 61000-6-(1,3), EN 61000-3-(2,3),
EN 55024, EN 50204, EN 61204-3, EN 61000-4-(2, 3, 4, 5, 6, 8, 11)
RoHS
2011/65/EU
Note:
3,000
1,500
500
Vac
Vac
Vac
100
MΩ
1. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PSF-155 │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/12/2014
page 3 of 7
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curve
-20
70
°C
storage temperature
typ
-40
85
°C
operating humidity
non-condensing
20
90
%
storage humidity
non-condensing
10
90
%
vibration
at 10~500 Hz, 10 min per cycle for 60 minutes
each test along the X, Y, and Z axis
2
G
DERATING CURVES
Load vs. Temperature
80
“CF”, enclosed with fan
or with 23 CFM fan
70
60
all other models
100
Load (%)
Load (%)
100
Load vs. Input Voltage
(at 25°C)
50
40
Safe operating area
30
20
60
40
20
-10
0
10
20
30
40
50
60
0
70
90
95
100
Ambient Temperature (°C)
105
110
115
120
~
~
0
-20
80
264
Input Voltage (Vac) 60 Hz
MECHANICAL
parameter
conditions/description
dimensions
enclosed: 179 x 98 x 38
enclosed with fan:179 x 98 x 55.4
min
weight
enclosed
enclosed with fan
typ
units
mm
mm
0.64
0.68
cui.com
max
kg
kg
For more information, please visit the product page.
CUI Inc │ SERIES: PSF-155 │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/12/2014
MECHANICAL DRAWING
CNF
units: mm
CN1 Pin Connections
CN2 Pin Connections
PIN
Function
1
AC/L
2
AC/N
1
AC OK
3
FG ⏚
2
BAT LOW
3
PSF-155-A: (13.8 V/20 mA)
PSF-155-C: (27.6 V/20 mA)
4
-Vo1
5
+Vo1
6
+Vo2 (+ BAT)
71
-Vo2 (- BAT)
8
+Vo3 (+5 V)
2
PIN
Function
PSF-155-A, PSF-155-C3
PSF-155-B, PSF-155-D4
1 2
3 4
AC OK
BAT LOW
CF
units: mm
CN1 Pin Connections
CN2 Pin Connections
PIN
Function
1
AC/L
2
AC/N
1
AC OK
3
FG ⏚
2
BAT LOW
3
PSF-155-A: (13.8 V/20 mA)
PSF-155-C: (27.6 V/20 mA)
4
-Vo1
5
+Vo1
6
+Vo2 (+ BAT)
71
-Vo2 (- BAT)
82
+Vo3 (+5 V)
Notes:
1.
2.
3.
4.
PIN
Function
PSF-155-A, PSF-155-C3
PSF-155-B, PSF-155-D4
1 2
3 4
AC OK
BAT LOW
To protect product damage do not connect the GND port with -BAT port.
PSF-155-B and PSF-155-D only.
For PSF-155-A & PSF-155-C, CN2 mates with JST XHP-3 or equivalent and JST SXH-001 T-P0.6 or equivalent.
For PSF-155-B & PSF-155-D, CN2 mates with JST XHP-4 or equivalent and JST SXH-001 T-P0.6 or equivalent.
cui.com
page 4 of 7
For more information, please visit the product page.
CUI Inc │ SERIES: PSF-155 │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/12/2014
page 5 of 7
BATTERY CHARGING SPECIFICATIONS
Block Diagram
Alarm Circuit for
PSF-155-A & PSF-155-C
Alarm Circuit for
PSF-155-B & PSF-155-D
PSF-155-A & PSF-155-C
Alarm Signal for AC OK and Battery Low
Function
AC OK
Battery
Low
Notes:
Description
Alarm Output
The signal is low when the power
supply turns on
Low
(0.3 V max. at 30 mA)
The signal is high when the power
supply turns off
High/open
(external voltage < 50 V)
The signal is low when the voltage of
the battery is below:
12 V (PSF-155-A), 22 V (PSF-155-C)
Low
(0.3 V max. at 30 mA)
The signal is high when the voltage of
the battery is above:
12 V (PSF-155-A), 22 V (PSF-155-C)
High/open
(external voltage < 50 V)
1. Alarm signal is sent out through “AC OK” and “Battery Low” pins.
2. An external voltage source is required for this function. The maximum applied voltage is 50 V and the maximum sink current is 30 mA.
Internal Circuit of AC OK and Battery Low
PSF-155-A
PSF-155-C
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: PSF-155 │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/12/2014
BATTERY CHARGING SPECIFICATIONS (CONTINUED)
PSF-155-B & PSF-155-D
Alarm Signal for AC OK and Battery Low
Function
AC OK
Battery
Low
Notes:
Description
Alarm Output
The signal is low when the power
supply turns on
Low or short
The signal is high when the power
supply turns off
High/open
(external voltage < 30 V)
The signal is low when the voltage of
the battery is below:
12 V (PSF-155-B), 22 V (PSF-155-D)
Low or short
The signal is high when the voltage of
the battery is above:
12 V (PSF-155-B), 22 V (PSF-155-D)
High/open
(external voltage < 30 V)
1. Alarm signal is sent out through “AC OK” and “Battery Low” pins (relay contact type).
2. An external voltage source is required for this function. The maximum applied voltage is 30 V and the maximum sink current is 1 A.
Internal Circuit of AC OK and Battery Low
Notes:
1. All specifications measured at 25°C, 230Vac input voltage, and rated power unless otherwise noted.
cui.com
page 6 of 7
For more information, please visit the product page.
CUI Inc │ SERIES: PSF-155 │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/12/2014
page 7 of 7
REVISION HISTORY
rev.
description
date
1.0
initial release
11/25/2013
1.01
updated datasheet
12/12/2014
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.