Photoelectric sensors O500H.GP Diffuse sensors with background suppression sample drawing 20,2 124 33 Teach-in 18,1 47,7 LED 71,5 36,4 ø 17 general data sample picture type background suppression special type hygienic design light source pulsed PinPoint LED sensing distance Tw 60 ... 400 mm sensing range Tb 30 ... 400 mm power on indication LED green light indicator LED yellow sensing distance adjustment Teach-in and IO-Link wave length 630 nm suppression of reciprocal influence yes alignment optical axis < 1° approvals/certificates Ecolab electrical data response time / release time < 0,49 ms voltage supply range +Vs 10 ... 30 VDC current consumption max. (no load) 40 mA current consumption typ. 30 mA voltage drop Vd < 3 VDC output function light / dark operate output circuit push-pull output current < 100 mA short circuit protection yes reverse polarity protection yes mechanical data width / diameter 20,2 mm height / length 47,7 mm depth 36,4 mm type rectangular housing material stainless steel 1.4404 (V4A) front (optics) PMMA ambient conditions operating temperature -25 ... +60 °C protection class IP 68/69K & proTect+ 1 www.baumer.com 10/12/2014 Photoelectric sensors O500H.GP Diffuse sensors with background suppression order reference connection types O500H.GP-11125101 cable 4 pin, 2 m O500H.GP-11125102 flylead connector M12, L=300 mm 2 www.baumer.com 10/12/2014