P ARP O P LDI CUA TC I TO N NN O O TTE E XRpad2 3025 (In Development) Flat Panel X-ray Detectors Features and Benefits • • • • • • • • • • • 25 cm × 30 cm (10” × 12”) image High resolution 100 μm pixel pitch (5.0 lp/mm) Direct deposition Csl, for excellent image quality Up to 65,536 grey levels (16-bit ADC) Automatic Exposure Detection (AED) Wi-Fi interface (Station and Access Point mode) Docking connector for GigE, power and sync On-board pixel corrections and storage Sequence mode for tomosynthesis Fast preview image Robust and lightweight design Applications1 • Digital radiography Upgrade to Digital Radiography Overview XRpad2 3025 is a wireless, lightweight, cassette-sized flat panel detector for digital radiography based on a second-generation XRpad® design from PerkinElmer. Featuring a 7.4 million pixel image matrix, a best-in-class 100 μm pixel pitch, and a direct deposited CsI scintillator, the PerkinElmer XRpad2 3025 provides exceptional image quality. A 25 × 30 cm2 imaging area is provided, along with a removable rechargeable battery. A robust and lightweight aluminum frame with carbon-fiber entrance window and back cover allow for easier placement and cleaning. Automatic Exposure Detection, on-board corrections, and wireless access point mode simplify integration. We have over 20 years of experience partnering with customers to develop products in a wide range of X-ray applications. Let our digital imaging experience work for you. Unless otherwise specified, PerkinElmer Flat Panel X-ray Detectors are components intended to be integrated into products by X-ray system manufacturers. System manufacturers are responsible for qualifying and validating their products for their intended uses and meeting all applicable regulatory requirements. 1 Contents in this document are subject to change without notice. XRpad2 3025 (In Development) Imaging Performance Sensor Panel Amorphous silicon active TFT-diode array Limiting Resolution 5 cy/mm Scintillator Direct deposition CsI:Tl Typical MTF 70% (1 cy/mm), 40% (2 cy/mm),15% (4 cy/mm) for RQA5 Pixel Matrix 2508 × 3004 Typical DQE 75% (0 cy/mm), 60% (1 cy/mm), 40% (3 cy/mm) for RQA5 Pixel Pitch 100 µm Advanced Features Electronics Sequence Mode 10 fps (2 × 2 binned) Amplifiers Low noise ASICs with user selectable gains On-board Corrections Offset, gain and defect pixel ADC 16-bit On-board Storage Image storage with tagging Image Transfer Time Wired: 300 ms; Wireless: 2000 ms Fast Preview 4 × 4 binned quick preview image On-board Memory 1 GB DDR3, 8 GB SDHC card Environmental Mechanical Temperature 10 °C to 35 °C operating Size ISO 4090 for 25 cm × 30 cm (10” × 12”) cassette size Humidity 10% to 85% operating Active Area 248 mm × 298 mm Ingress Protection IPX4 rated (protection against splashing water) External Dimensions 282 mm (w) × 332 mm (l) × 15.5 mm (h) Accessories Weight 1.8 kg (4 lbs) Battery Rechargeable battery, 11.1 V Housing Aluminum frame with carbon-fiber entrance window Battery Charger External two bay charger 100 - 240 V AC 50/60 Hz Communications 8 7 6 Interface and Power Unit Status Display OLED display with Wi-Fi, LAN, battery, and sensor indicators Wireless Data I/F 802.11n Wi-Fi standard at 5 GHz Regulatory Wired Data I/F GigE, trigger and power via optional docking connector Standards X-ray I/F Integrated X-ray trigger control Automatic Exposure Detection D Optional IPU-2 external power supply 5 4 100 – 240 V AC, GigE and X-ray I/F ECO 3 REV EN IEC 60601-1:2006/AC:2010, EN IEC 60601-1-2:2007, FCC Part 15 subpart B/E, ETSI EN 301 893 V.1.7.1 (2012), ETSI EN 301 489-1 V1.9.2 (2011), ETSI EN 301 489-17 V2.2.1 (2012), EN ISO 10993-5:2009, EN ISO 10993-10:2013 Mechanical Characteristics (Dimensions in mm) 15.5 282 C B 332 T A MATERIAL AND FINISH REQUIREMENTS: USA PerkinElmer, Inc. 2175 Mission College Blvd Santa Clara, CA 95054 USA P: +1-844-726-8228 F: +1-408-969-6493 Germany United Kingdom PerkinElmer Dexela Limited Technologies GmbH & Co. KG A PerkinElmer Company PRINTED FORM OR TEMPLATE IS NOT In der Rehbach 22 Wenlock Business Centre 37389 VERSION 02 GUARANTEED TO BE THE CURRENT FRM DRAWING TEMPLATE 65396 Walluf Germany 50-52WITHIN WharfTHE Road VERSION. VERIFY DOCUMENT C/N 500011504 CONTROL CENTER THE CURRENT VERSION P: +49-6123-971-300 London N1 7EU United Kingdom PRIOR TO USE. F: +49-6123-971-600 P: +44-20-7148-3107 China PerkinElmer, Inc. No. 1670 Zhangheng Road DRAWN Zhangjiang Hi-Tech Park DATE Shanghai 201203, PRC ENGINEER P: +86-21-60645611 DATE F: +86-21-60645666 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF PERKINELMER MEDICAL IMAGING. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF PERKINELMER MEDICAL IMAGING IS PROHIBITED. 8 7 us through the contact form 6 provided or email [email protected]. 5 Visit our website at www.perkinelmer.com/imaging-components/ and contact For a complete listing of our global offices, visit www.perkinelmer.com/ContactUs Copyright ©2012-2016, PerkinElmer, Inc. All rights reserved. PerkinElmer® is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 011428B_01 PKI 4 UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE: MM[INCHES] TOLERANCES ARE: .X = 0.25[.01] .XX = 0.13[.005] ANGLES = 1 DO NOT SCALE DRAWING 3 S