Technical Specification PQ60280HZx22 35-75V 100V 28V 602W 2250V dc Half-brick Input Transient Input Output Max Power Isolation DC-DC Converter The PQ60280HZx22 PowerQor Zeta Half-brick converter is a next-generation, board-mountable, isolated, fixed switching frequency DC/DC converter. The Zeta series offers industry leading power density for standard isolated DC/DC converters with both a wide input range and a tightly regulated output. This module supplies an isolated step down voltage from 35-75V to 28V and is available in openframe and encased versions. RoHS Compliant (see last page). Protection Features • Input under-voltage lockout disables converter at low Vin conditions • Output current limit and short circuit protection protects converter and load from permanent damage and consequent hazardous conditions • Active back bias limit provides smooth startup with external load induced pre-bias • Auto-recovery output over-voltage protection protects load from damaging voltages • Thermal shutdown protects converter from abnormal environmental conditions Mechanical Features • Industry standard half-brick pin-out configuration • Size: 2.30" x 2.40" x 0.428", 58.4 x 61.0 x 10.9 mm • Total weight: 2.6 oz. (75 g) PQ60280HZx22 Model Operational Features • High efficiency, 94% at full rated load current • Delivers up to 21.5A of output current (602W) with optional base-plate configuration • Input voltage range: 35-75V • Fixed frequency switching provides predictable EMI performance • No minimum load requirement means no preload resistors required • Wide output voltage trim range (-50%, +10%), see trim section Control Features • On/Off control referenced to input side (positive and negative logic options are available) • Remote sense for the output voltage Page No. Safety Features • UL 60950-1:R2011-12 • EN60950-1/A12:2011 • CAN/CSA-C22.2 No. 60950-1/A1:2011 Product # PQ60280HZx22 Contents Phone 1-888-567-9596 Mechanical Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Standards & Qualifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Technical Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Applications Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 www.synqor.com Doc.# 005-0005788 Rev. D 12/26/13 Page 1 Input: 35-75V Output: 28V Current: 21.5A Package: Half-brick Open Frame Mechanical 2.40 [61] 1.400 [35,56] 1.000 [25,4] .700 [17,78] .400 [10,16] 2.30 [58,4] .059 .028 [1,5 0,71] BOTTOMSIDE CLEARANCE 9 8 7 6 5 TOP VIEW 1.900 [48,26] .19 [4,8] SIDE VIEW 1 2 B 3 4 .400 [10,16] .800 [20,32] .50 [12,7] .428 .018 [10,87 0,45] OVERALL HEIGHT .180 [4,57] SEE NOTE 3 1.000 [25,4] 1.400 [35,56] NOTES 1) 2) PIN DESIGNATIONS Pins 1-4, 6-8, and B are 0.040” (1.02mm) diameter, with 0.080” (2.03mm) diameter standoff shoulders. Pins 5 and 9 are 0.080” (2.03 mm) diameter with 0.125” (3.18mm) diameter standoff shoulders. 3) Other pin extension lengths available. 4) All Pins: Material - Copper Alloy Finish: Matte Tin over Nickel plate Undimensioned components are shown for visual reference only. 5) 6) 7) 8) 9) All dimensions in inches (mm) 'Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm) Open Frame Weight:2.6 oz. (75 g) Workmanship: Meets or exceeds IPC-A-610 Class II UL/TUV standards require a clearance greater than 0.04” 1.02mm) between input and output for Basic insulation. This issue should be considered if any copper traces are on the top side of the user’s board. Note that the ferrite cores are considered part of the input/ primary circuit. Product # PQ60280HZx22 Phone 1-888-567-9596 Pin Name 1 Vin(+) 2 ON/OFF B SHARE(+) 3 4 5 6 7 8 9 SHARE(-) Vin(–) Vout(–) SENSE(–) TRIM SENSE(+) Vout(+) Function Positive input voltage TTL input to turn converter on and off, referenced to Vin(–), with internal pull up. Active current share differential pair (See note 4) Negative input voltage Negative output voltage Negative remote sense (See note 1) Output voltage trim (See note 2) Positive remote sense (See note 3) Positive output voltage Notes: 1) SENSE(–) should be connected to Vout(–) either remotely or at the converter. 2) Leave TRIM pin open for nominal output voltage. 3) SENSE(+) should be connected to Vout(+) either remotely or at the converter. 4) Full-Featured option only. Pin 3 and Pin B not populated on standard model. www.synqor.com Doc.# 005-0005788 Rev. D 12/26/13 Page 2 Input: 35-75V Output: 28V Current: 21.5A Package: Half-brick Encased Mechanical 2.486 2.00 1.400 1.000 [63.14 0.5] SIDE VIEW [35.56 ] [17.78 ] .400 [10.16 ] [ .243 [6.17 8 6 7 .020 0.5] .243 [6.17 .020 0.5] 2 B 4 3 .400 [10.16 ] .800 [20.32 ] 1.00 [25.4 ] 1.400 .543 .020 [13.79 0.5] THRU HOLE M3 (SEE NOTE 8) STANDOFFS (4) Applied torque per screw should not exceed 6in-lb. (0.7 Nm). 2) Baseplate flatness tolerance is 0.004" (.10 mm) TIR for surface. Pin Name 1 Vin(+) Pins 1-4, 6-8, and B are 0.040” (1.02mm) diameter, with 0.080” (2.03mm) diameter standoff shoulders. Pins 5 and 9 are 0.080” (2.03 mm) diameter with 0.125” (3.18 mm) diameter standoff shoulders. All Pins: Material - Copper Alloy; Finish - Matte Tin over Nickel plate Undimensioned components are shown for visual reference only. Weight: 5 oz. (142g) typical Threaded and Non-Threaded options available All dimensions in inches (mm). Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm) unless otherwise noted. 10) Recommended pin length is 0.03" (0.76 mm) greater than the PCB thickness. 11) Workmanship: Meets or exceeds IPC-A-610C Class II Product # PQ60280HZx22 [ ] PIN DESIGNATIONS 1) 6) 7) 8) 9) +.007 -.010 +0.17 0.69 -0.25 BOTTOMSIDE CLEARANCE .027 [35.56 ] NOTES 5) .020 0.5] 1.90 [48.3 ] 1 4) .163 [4.14 ] TOP VIEW 1.90 [48.3 ] 3) ] 5 .020 0.5] .233 [5.92 +.002 .512 -.005 +0.05 13 -0.12 OVERALL HEIGHT [25.4 ] .700 9 2.386 [60.6 .020 [50.8 ] Phone 1-888-567-9596 2 ON/OFF B SHARE(+) 3 4 5 6 7 8 9 SHARE(-) Vin(–) Vout(–) SENSE(–) TRIM SENSE(+) Vout(+) Function Positive input voltage TTL input to turn converter on and off, referenced to Vin(–), with internal pull up. Active current share differential pair (See note 4) Negative input voltage Negative output voltage Negative remote sense (See note 1) Output voltage trim (See note 2) Positive remote sense (See note 3) Positive output voltage Notes: 1) SENSE(–) should be connected to Vout(–) either remotely or at the converter. 2) Leave TRIM pin open for nominal output voltage. 3) SENSE(+) should be connected to Vout(+) either remotely or at the converter. 4) Full-Featured option only. Pin 3 and Pin B not populated on standard model. www.synqor.com Doc.# 005-0005788 Rev. D 12/26/13 Page 3 Input: 35-75V Output: 28V Current: 21.5A Package: Half-brick Technical Specifications PQ60280HZx22 Electrical Characteristics Ta = 25 °C, airflow rate = 300 LFM, Vin = 48V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. ABSOLUTE MAXIMUM RATINGS Input Voltage Non-Operating Operating Operating Transient Protection Isolation Voltage Input to Output Operating Temperature Storage Temperature Voltage at ON/OFF input pin INPUT CHARACTERISTICS Operating Input Voltage Range Input Under-Voltage Lockout Turn-On Voltage Threshold Turn-Off Voltage Threshold Lockout Voltage Hysteresis Maximum Input Current No-Load Input Current Disabled Input Current (Option N) Disabled Input Current (Option P) Response to Input Transient Input Reflected Ripple Current Input Terminal Ripple Current Recommended Input Fuse Recommended External Input Capacitance Input Filter Component Values (L\C) OUTPUT CHARACTERISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Enabled Back-Drive Current Limit while Disabled Maximum Output Capacitance Electrolytic EFFICIENCY 100% Load 50% Load Product # PQ60280HZx22 Typ. -1 -40 -45 -2 Max. Units Notes & Conditions 100 80 100 V V V 2250 100 125 18 V °C °C V 35 48 75 V 32.0 30.0 1.5 33.0 31.0 2.0 34.0 32.0 2.5 21 230 8 40 V V V A mA mA mA V mA mA A µF µH\µF 20 180 5 30 4 30 250 40 220 0.75\11 27.16 28.00 28.84 V 420 28.70 % % mV V ±0.25 ±0.25 -420 27.30 170 45 0 23.0 Phone 1-888-567-9596 0 25.0 11.2 7 3 340 90 21.5 27.5 94 95 www.synqor.com 4 5 Continuous Continuous 1 s transient, square wave 100% Load, 35V Vin, trimmed up 10% 0.50V/μs input transient, full load, 100μF load cap RMS thru 4.7μH inductor RMS Fast acting external fuse recommended Typical ESR 0.1-0.2Ω; Figure 13 Internal values See note 1 See note 1 mV mV A A V A mA mF Over sample, line, load, temperature & life 20MHz bandwidth; see Note 2 Full load Full load Subject to thermal derating Output Voltage 10% Low See note 3 Negative current drawn from output Negative current drawn from output Nominal Vout at full load (resistive load) % % Figures 1 - 2 Figures 1 - 2 Doc.# 005-0005788 Rev. D 12/26/13 Page 4 Input: 35-75V Output: 28V Current: 21.5A Package: Half-brick Technical Specifications PQ60280HZx22 Electrical Characteristics (continued) Ta = 25 °C, airflow rate = 300 LFM, Vin = 48V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C baseplate temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions DYNAMIC CHARACTERISTICS Output Voltage during Load Current Transient Step Change in Output Current (0.1A/µs) 1 V 50% to 75% to 50% Iout max, 15 μF load cap Step Change in Output Current (2A/µs) 1.5 V 50% to 75% to 50% Iout max, 15 μF load cap µs Settling time 750 To within 1% Vout nom Turn-On Transient Turn-On Time 15 25 35 ms Vout=90% nom, Figures 9 & 10; see note 5 Output Voltage Overshoot 0 % ISOLATION CHARACTERISTICS Isolation Voltage (dielectric strength) 2250 V See Absolute Maximum Ratings Isolation Resistance 30 MΩ Isolation Capacitance (input to output) 1000 pF See Note 4 TEMPERATURE LIMITS FOR POWER DERATING CURVES Semiconductor Junction Temperature 125 °C Package rated to 150°C Board Temperature 125 °C UL rated max operating temp 130°C Transformer Temperature 125 °C FEATURE CHARACTERISTICS Switching Frequency Regulation Stage 230 240 250 kHz Switching Frequency Isolation Stage 115 120 125 kHz ON/OFF Control (Option P) Off-State Voltage -2.0 0.8 V On-State Voltage 2.4 18.0 V ON/OFF Control (Option N) Off-State Voltage 2.4 18.0 V On-State Voltage -2.0 0.8 V ON/OFF Control (Either Option) Application notes; Figures A & B Pull-Up Voltage 15 18 V Pull-Up Resistance 49.9 kΩ Output Voltage Trim Range -50 10 % Measured across Pins 8 & 6; Figure C Output Over-Voltage Protection 113 118 123 % Over Full Temperature Range; % of nominial Vout Over-Temperature Shutdown 125 °C Average PCB Temperature Over-Temperature Shutdown Restart Hysteresis 10 °C RELIABILITY CHARACTERISTICS Calculated MTBF (Telcordia) 2.1 106 Hrs. TR-NWT-000332; 80% load, 300LFM, 40°C Ta Calculated MTBF (MIL-217) 1.9 106 Hrs. MIL-HDBK-217F; 80% load, 300LFM, 40°C Ta Field Demonstrated MTBF 106 Hrs. See our website for details Note 1: Line and load regulation is limited by duty cycle quantization and does not indicate a shift in the internal voltage reference. Note 2: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 3: If the output voltage falls below the Output DC Current Limit Shutdown Voltage for more than 50ms, then the unit will enter into hiccup mode, with a 500ms off-time. Note 4: Higher values of isolation capacitance can be added external to the module. Note 5: Additional 25ms between enable and start of Turn-On time for N logic full-featured units to set up communication. Product # PQ60280HZx22 Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005788 Rev. D 12/26/13 Page 5 Input: 35-75V Output: 28V Current: 21.5A Package: Half-brick Technical Specifications Standards Compliance & Qualification Testing Parameter Notes & Conditions STANDARDS COMPLIANCE UL 60950-1:R2011-12 Basic insulation EN60950-1/A12:2011 CAN/CSA-C22.2 No. 60950-1/A1:2011 Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or download from the SynQor website. Parameter QUALIFICATION TESTING Life Test Vibration Mechanical Shock Temperature Cycling Power/Thermal Cycling Design Marginality Humidity Solderability Product # PQ60280HZx22 # Units 32 5 5 10 5 5 5 15 pins Phone 1-888-567-9596 Test Conditions 95% rated Vin and load, units at derating point, 1000 hours 10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis 100g minimum, 2 drops in x, y and z axis -40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles Toperating = min to max, Vin = min to max, full load, 100 cycles Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load 85 °C, 95% RH, 1000 hours, continuous Vin applied except 5 min/day MIL-STD-883, method 2003 www.synqor.com Doc.# 005-0005788 Rev. D 12/26/13 Page 6 Input: 35-75V Output: 28V Current: 21.5A Package: Half-brick 100 100 95 95 90 90 85 85 Efficiency (%) Efficiency (%) Technical Figures 80 75 70 75 Vin 6 9 12 Load Current (A) 15 18 55º C 100 21 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 200 300 400 Air Flow (LFM) Figure 2: Efficiency at nominal output voltage and 60% rated power vs. airflow rate for ambient air temperatures of 25°C, 40°C, and 55°C (nominal input voltage). 60 60 50 50 Power Dissipation (W) Power Dissipation (W) 40º C 60 60 3 25º C 65 48 Vin 0 75 70 35 Vin 65 80 40 40 30 30 20 20 35 Vin 10 25º C 40º C 10 48 Vin 55º C 75 Vin 0 0 0 3 6 9 12 Load Current (A) 15 18 21 Figure 3: Power Dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C. 100 200 300 400 Air Flow (LFM) Figure 4: Power Dissipation at nominal output voltage and 60% rated power vs. airflow rate for ambient air temperatures of 25°C, 40°C, and 55°C (nominal input voltage). 21 18 Iout(A) 15 12 9 400LFM(2.0m/s) 6 300LFM(1.5m/s) 200LFM(1.0m/s) 3 100LFM(0.5 m/S) 0 25 40 55 70 85 Semiconductor junction temperature is within 1°C of surface temperature Ambient Air Temperature(°C) Figure 5: Thermal Derating (max output current vs. ambient air temperature) for airflow rates of 100 LFM through 400 LFM with air flowing from pin 4 to pin 1 (nominal input voltage). Product # PQ60280HZx22 Phone 1-888-567-9596 Figure 6: Thermal Image of converter at 11.7 amp load current (327.6W) with 55°C air flowing at the rate of 200 LFM. Air is flowing from pin 3 to pin 1 (nominal input voltage). www.synqor.com Doc.# 005-0005788 Rev. D 12/26/13 Page 7 Input: 35-75V Output: 28V Current: 21.5A Package: Half-brick Technical Figures 21 18 Iout(A) 15 12 9 400LFM(2.0m/s) 6 300LFM(1.5m/s) 200LFM(1.0m/s) 3 100LFM(0.5 m/S) 0 25 40 55 Ambient Air Temperature(°C) 70 85 Figure 7: Thermal Derating (max output current vs. ambient air temperature) for airflow rates of 100 LFM through 400 LFM with air flowing lenghtwise from input to output (nominal input voltage). Figure 8: Thermal Image of converter at 11.9 amp load current (333.2W) with 55°C air flowing at the rate of 200 LFM. Air is flowing across the converter from input to output (nominal input voltage). Figure 9: Turn-on Transient at full load (resistive load) (20 ms/div). Input voltage pre-applied. Top Trace: Vout (10V/div). Bottom Trace: ON/OFF input(10V/div) Figure 10: Turn-on Transient at zero load (20 ms/div). Top Trace: Vout (10V/ div). Bottom Trace: ON/OFF input (10V/div) Figure 11: Output Voltage Response to Step-Change in Load Current (50%75%-50% of Iout(max); dI/dt = 0.1A/µs). Load cap: 1µF ceramic and 15µF tanalum output capacitors. Top trace: Vout (1V/div). Bottom trace: Iout (10A/ div). Figure 12: Output Voltage Response to Step-Change in Load Current (50%75%-50% of Iout(max): dI/dt = 2A/µs). Load cap: 1µF ceramic and 15µF tanalum output capacitors. Top trace: Vout (2V/div). Bottom trace: Iout (10A/ div). Product # PQ60280HZx22 Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005788 Rev. D 12/26/13 Page 8 Input: 35-75V Output: 28V Current: 21.5A Package: Half-brick Technical Figures Figure 13: Test Set-up Diagram showing measurement points for Input Terminal Ripple Current (Figure 14), Input Reflected Ripple Current (Figure 15) and Output Voltage Ripple (Figure 16). Figure 14: Input Terminal Ripple Current, ic, at full rated output current and nominal input voltage with 4.7µH source impedance and 220µF electrolytic capacitor (Ch.1 500mA/div, 2µs/div). (See Figure 13). Figure 15: Input Reflected Ripple Current, is, through a 4.7 µH source inductor at nominal input voltage and rated load current (10 mA/div, 2µs/div). (See Figure 13). Figure 16: Output Ripple votlage at nominal input voltage and rated load current (200 mV/div, 2µs/div). Load capacitance: 1µF ceramic and 15µF tanalum output capacitors. Bandwidth: 20 MHz. (See Figure 13). 30 Output Voltage (V) 25 20 15 Current-Limit Shutdown 10 35Vin 5 48Vin 75Vin 0 0 5 10 15 20 25 30 Load Current (A) Figure 17: Output I-V Characteristics (output voltage vs. load current) showing typical current limit curves and converter shutdown points. Product # PQ60280HZx22 Phone 1-888-567-9596 Figure 18: Output Short Load Current (20A/div;20ms/div) as a function of time when the converter attempts to turn on into a 1 mΩ short circuit. www.synqor.com Doc.# 005-0005788 Rev. D 12/26/13 Page 9 Input: 35-75V Output: 28V Current: 21.5A Package: Half-brick Applications Section BASIC OPERATION AND FEATURES CONTROL FEATURES This converter series uses a two-stage power conversion topology. The first stage keeps the output voltage constant over variations in line, load, and temperature. The second stage uses a transformer to provide the functions of input/output isolation and voltage stepdown to achieve the low output voltage required. REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits the user to control when the converter is on or off. This input is referenced to the return terminal of the input bus, Vin(-). In negative logic versions, the ON/OFF signal is active low (meaning that a low voltage turns the converter on). In positive logic versions, the ON/OFF input is active high (meaning that a high voltage turns the converter on). Figure A details possible circuits for driving the ON/OFF pin. Figure B is a detailed look of the internal ON/OFF circuitry. See Ordering Information page for available enable logics. REMOTE SENSE Pins 8(+) and 6(-): The SENSE(+) and SENSE(-) inputs correct for voltage drops along the conductors that connect the converter’s output pins to the load. Both the first stage and the second stage switch at a fixed frequency for predictable EMI performance. Rectification of the transformer’s output is accomplished with synchronous rectifiers. These devices, which are MOSFETs with a very low on-state resistance, dissipate significantly less energy than Schottky diodes, enabling the converter to achieve high efficiency. Dissipation throughout the converter is so low that it does not require a heatsink or even a baseplate for operation in many applications; however, adding a heatsink provides improved thermal derating performance in extreme situations. To further withstand harsh environments and thermally demanding applications, certain models are available totally encased. See Ordering Information page for available thermal design options. SynQor half-brick converters use the industry standard footprint and pin-out. ON/OFF ON/OFF ON/OFF Vin(_) Vin(_) Vin(_) Remote Enable Circuit Negative Logic (Permanently Enabled) 5V ON/OFF Positive Logic (Permanently Enabled) TTL/ CMOS ON/OFF Direct Logic Drive 5V 100% –2 Δ% Δ% = | Vnominal – Vdesired ) kΩ Vnominal | × 100% To increase the output voltage, the user should connect a resistor between Pin 7 (TRIM) and Pin 8 (SENSE(+) input). For a desired increase of the nominal output voltage, the value of the resistor should be: 50k ON/OFF ( Vin(_) Figure A: Various circuits for driving the ON/OFF pin. 18V(max) Rtrim-down = where Vin(_) Open Collector Enable Circuit Pin 8 should be connected to Vout(+) and Pin 6 should be connected to Vout(-) at the point on the board where regulation is desired. If these connections are not made, the converter will deliver an output voltage that is slightly higher than its specified value. Note: The Output Over-Voltage Protection circuit senses the voltage across the output (Pins 9 and 5) to determine when it should trigger, not the voltage across the converter’s sense leads (Pins 8 and 6). Therefore, the resistive drop on the board should be small enough so that output OVP does not trigger, even during load transients. OUTPUT VOLTAGE TRIM (Pin 7): The TRIM input permits the user to adjust the output voltage across the sense leads up or down according to the trim range specifications. SynQor uses industry standard trim equations. To decrease the output voltage, the user should connect a resistor between Pin 7 (TRIM) and Pin 6 (SENSE(–) input). For a desired decrease of the nominal output voltage, the value of the resistor should be: 10k TTL Rtrim-up = Vin(_) ( ) Vnominal – 2 × Vdesired + Vnominal kΩ 1.225 Vdesired – Vnominal Figure B: Internal ON/OFF pin circuitry Product # PQ60280HZx22 Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005788 Rev. D 12/26/13 Page 10 Input: 35-75V Output: 28V Current: 21.5A Package: Half-brick Applications Section The Trim Graph in Figure C shows the relationship between the trim resistor value and Rtrim-up and Rtrim-down, showing the total range the output voltage can be trimmed up or down. Note: The TRIM feature does not affect the voltage at which the output over-voltage protection circuit is triggered. Trimming the output voltage too high may cause the over-voltage protection circuit to engage, particularly during transients. It is not necessary for the user to add capacitance at the TRIM pin. The node is internally filtered to eliminate noise. Total DC Variation of Vout: For the converter to meet its full specifications, the maximum variation of the DC value of Vout, due to both trimming and remote load voltage drops, should not be greater than that specified for the output voltage trim range. 100,000.0 Trim Resistance (kOhms) 10,000.0 1,000.0 100.0 10.0 1.0 0.1 0.0 0 5 10 15 20 % increase Vout 25 30 35 Figure C: Trim Graph Product # PQ60280HZx22 40 % decrease Vout Phone 1-888-567-9596 45 50 Protection Features Input Under-Voltage Lockout (UVLO): The converter is designed to turn off when the input voltage is too low, helping to avoid an input system instability problem, which is described in more detail in the application note titled “Input System Instability” on the SynQor website. When the input is rising, it must exceed the typical “Turn-On Voltage Threshold”* before the converter will turn on. Once the converter is on, the input must fall below the typical "Turn-Off Voltage Threshold"* before the converter will turn off. Output Current Limit (OCP): If the output current exceeds the “Output DC Current Limit Inception” value*, then a fast linear current limit controller will reduce the output voltage to maintain a constant output current. If as a result, the output voltage falls below the “Output DC Current Limit Shutdown Voltage”* for more than 50 ms, then the unit will enter into hiccup mode, with a 500 ms off-time. The unit will then automatically attempt to restart. Back-Drive Current Limit: If there is negative output current of a magnitude larger than the “Back-Drive Current Limit while Enabled” specification*, then a fast back-drive limit controller will increase the output voltage to maintain a constant output current. If this results in the output voltage exceeding the “Output OverVoltage Protection” threshold*, then the unit will shut down. Output Over-Voltage Limit (OVP): If the voltage across the output pins exceeds the "Output Over-Voltage Protection" threshold*, the converter will immediately stop switching. This prevents damage to the load circuit due to 1) excessive series resistance in output current path from converter output pins to sense point, 2) a release of a short-circuit condition, or 3) a release of a current limit condition. Load capacitance determines exactly how high the output voltage will rise in response to these conditions. After 500 ms the converter will automatically restart for all but the S Feature Set option, which is latching and will not restart until input power is cycled or the ON/OFF input is toggled. During an output over-voltage condition, the converter's LED will illuminate. For units with latching OVP (S Feature Set), once the over-voltage condition has been removed the LED will flash steadily until the input power or the ON/OFF input is toggled. Over-Temperature Shutdown (OTP): A thermister on the converter senses the average temperature of the module. The thermal shutdown circuit is designed to turn the converter off when the temperature at the sensed location reaches the “OverTemperature Shutdown” value*. It will allow the converter to turn on again when the temperature of the sensed location falls by the amount of the “Over-Temperature Shutdown Restart Hysteresis”*. Startup Inhibit Period: The Startup Inhibit Period ensures that the converter will remain off for approximately 500 ms when it is shut down due to a fault. This generates a 2 Hz “hiccup mode,” preventing the converter from overheating. There are multiple ways the converter can be shut down, initiating a Startup Inhibit Period: • Output Over-Voltage Protection • Current Limit • Short Circuit Protection * See Electrical Characteristics section. www.synqor.com Doc.# 005-0005788 Rev. D 12/26/13 Page 11 Input: 35-75V Output: 28V Current: 21.5A Package: Half-brick Applications Section APPLICATION CONSIDERATIONS Input System Instability: This condition can occur because any DC-DC converter appears incrementally as a negative resistance load. A detailed application note titled “Input System Instability” is available on the SynQor website which provides an understanding of why this instability arises, and shows the preferred solution for correcting it. Thermal Considerations: For baseplated and encased versions, the max operating baseplate temperature, TB, is 100ºC. Refer to the Thermal Derating Curves in the Technical Figures section to see the available output current at baseplate temperatures below 100ºC. A power derating curve can be calculated for any heatsink that is attached to the base-plate of the converter. It is only necessary to determine the thermal resistance, RTHBA, of the chosen heatsink between the baseplate and the ambient air for a given airflow rate. This information is usually available from the heatsink vendor. The following formula can the be used to determine the maximum power the converter can dissipate for a given thermal condition if its base-plate is to be no higher than 100ºC. Application Circuits: A typical circuit diagram, Figure D below details the input filtering and voltage trimming. Input Filtering and External Input Capacitance: Figure E below shows the internal input filter components. This filter dramatically reduces input terminal ripple current, which otherwise could exceed the rating of an external electrolytic input capacitor. The recommended external input capacitance is specified in the Input Characteristics section of the Electrical Specifications. More detailed information is available in the application note titled “EMI Characteristics” on the SynQor website. Pdiss 100ºC - TA RTHBA This value of maximum power dissipation can then be used in conjunction with the data shown in the Power Dissipation Curves in the Technical Figures section to determine the maximum load current (and power) that the converter can deliver in the given thermal condition. max Output Filtering and External Output Capacitance: The internal output filter components are shown in Figure E below. This filter dramatically reduces output voltage ripple. Some minimum external output capacitance is required, as specified in the Output Characteristics area of the Electrical Characteristics section. No damage will occur without this capacitor connected, but peak output voltage ripple will be much higher. For convenience, Thermal Derating Curves are provided in the Technical Figures section. Vin(+) Vin Vout(+) Vsense(+) Electrolytic Capacitor External Input Filter = ON/OFF Trim Vsense(_) Vin(_) Rtrim-up or Rtrim-down Cload Iload Vout(_) Figure D: Typical Application Circuit (negative logic unit, permanently enabled). Lin Vin(+) Vout(+) C1 C2 Regulation Stage Current Sense Isolation Stage Vin(_) Vout(-) Figure E: Internal Input and Output Filter Diagram (component values listed in Electrical Characteristics section) Product # PQ60280HZx22 Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005788 Rev. D 12/26/13 Page 12 Input: 35-75V Output: 28V Current: 21.5A Package: Half-brick Applications Section Active Current Share Application Section Overview: The full-featured option, which is specified by an “F” as the last character of the part number, supports current sharing by adding two additional pins: SHARE(+) and SHARE(-) • Input power pins and output power pins should be tied together between units, preferably with wide overlapping copper planes, after any input common-mode choke. • The SHARE(+) and SHARE(-) pins should be routed between all paralleled units as a differential pair. • The ON/OFF pins should be connected in parallel, and rise/fall times should be kept below 2 ms. • The SENSE(+) and SENSE(-) pins should be connected either locally at each unit or separately to a common sense point. If an output common-mode choke is used, sense lines should be connected on the module-side of the choke. • If the TRIM pin is used, then each unit should have its own trim resistor connected locally between TRIM and SENSE(+) or SENSE(-). Connection of Paralleled Units: Up to 100 units can be placed in parallel. In this current share architecture, one unit is dynamically chosen to act as a master, controlling all other units. It cannot be predicted which unit will become the master at any given time, so units should be wired symmetrically (see Figures F & G). Vin(+) Sense(+) On/Off ≥1 nF Elec. Cap. A A Share(+) Trim Vin(-) Vout(-) Vin(+) Vout(+) Sense(+) On/Off Load ≥10 μF Share(-) Sense(-) Electrolytic Capacitor 470 nH (nom) Vout(+) B B 470 nH (nom) A Trim Share(+) ≥10 μF Share(-) Sense(-) Vin(-) B Vout(-) Up to 100 Units Vin(+) On/Off Electrolytic Capacitor Share(+) 470 nH (nom) Vout(+) Sense(+) A Trim ≥10 μF Share(-) Sense(-) Vin(-) B Vout(-) Figure F: Typical Application Circuit for Paralleling of Full-Featured Units with an Input Common-Mode Choke. If an input common-mode choke is used, Vin(-) MUST be tied together AFTER the choke for all units. 470 nH (nominal) inductor or an output common-mode choke is required for outputs >18 V. See Figure G for output common-mode choke configuration. Product # PQ60280HZx22 Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005788 Rev. D 12/26/13 Page 13 Input: 35-75V Output: 28V Current: 21.5A Package: Half-brick Applications Section Automatic Configuration: The micro-controller inside each power converter unit is programmed at the factory with a unique chip number. In every other respect, each shared unit is identical and has the same orderable part number. On initial startup (or after the master is disabled or shuts down), each unit determines the chip number of every other unit currently connected to the shared serial bus formed by the SHARE(+) and SHARE(-) pins. The unit with the highest chip number dynamically reconfigures itself from slave to master. The rest of the units (that do not have the highest chip number) become slaves. The master unit then broadcasts its control state over the shared serial bus on a cycle-by-cycle basis. The slave units interpret and implement the control commands sent by the master, mirroring every action of the master unit. If the master is disabled or encounters a fault condition, all units will immediately shut down, and if the master unit is unable to restart, then the unit with the next highest chip number will become master. If a slave unit is disabled or encounters a fault condition, all other units continue to run, and the slave unit can restart seamlessly. Automatic Interleaving: The slave units automatically lock frequency with the master, and interleave the phase of their switching transitions for improved EMI performance. To obtain the phase angle relative to the master, each slave divides 360 degrees by the total number of connected units, and multiples the result by its rank among chip numbers of connected units. ORing Diodes placed in series with the converter outputs must also have a resistor smaller than 500 Ω placed in parallel. This resistor keeps the output voltage of a temporarily disabled slave unit consistent with the active master unit. If the output voltage of the slave unit were allowed to totally discharge, and the slave unit tried to restart, it would fail because the slave reproduces the duty cycle of the master unit, which is running in steady state and cannot repeat an output voltage soft-start. Common-Mode Filtering must be either a single primary side choke handling the inputs from all the paralleled units, or multiple chokes placed on the secondary side. This ensures that a solid Vin(-) plane is maintained between units. Adding a common-mode choke at the output eliminates the need for the 470 nH indcutor at the output of shared units when Vout > 18 V. If an output common-mode choke is used, sense connections must be made on the module-side of the choke. Resonance Between Output Capacitors is Possible: When multiple higher-voltage modules are paralleled, it is possible to excite a series resonance between the output capacitors internal to the module and the parasitic inductance of the module output pins. This is especially likely at higher output voltages where the module internal capacitance is relatively small. This problem is independent of external output capacitance. For modules with an output voltage greater than 18 V, to ensure that this resonant frequency is below the switching frequency it is recommended to add a nominal 470 nH of inductance, located close to the module, in series with each converter output. There must be at least 10 ¼F of capacitance per converter, located on the load-side of that inductor. The inductance could be from the leakage inductance of a secondary-side common-mode choke; in which case the output capacitor should be appropriately sized for the chosen choke. When using an output common-mode choke, the Sense lines must be connected on the module-side of the common-mode choke (see Figure G). Product # PQ60280HZx22 Phone 1-888-567-9596 RS-485 Physical Layer: The internal RS-485 transceiver includes many advanced protection features for enhanced reliability: • Current Limiting and Thermal Shutdown for Driver Overload Protection • IEC61000 ESD Protection to +/- 16.5 kV • Hot Plug Circuitry – SHARE(+) and SHARE(-) Outputs Remain Tri-State During Power-up/Power-down Internal Schottky Diode Termination: Despite signaling at high speed with fast edges, external termination resistors are not necessary. Each receiver has four Schottky diodes built in, two for each line in the differential pair. These diodes clamp any ringing caused by transmission line reflections, preventing the voltage from going above about 5.5 V or below about -0.5 V. Any subsequent ringing then inherently takes place between 4.5 and 5.5 V or between -0.5 and 0.5 V. Since each receiver on the bus contains a set of clamping diodes to clamp any possible transmission line reflection, the bus does not necessarily need to be routed as a daisy-chain. Pins SHARE(+) and SHARE(-) are referenced to Vin(-), and therefore should be routed as a differential pair near the Vin(-) plane for optimal signal integrity. The maximum difference in voltage between Vin() pins of all units on the share-bus should be kept within 0.3 V to prevent steady-state conduction of the termination diodes. Therefore, the Vin(-) connections to each unit must be common, preferably connected by a single copper plane. Share Accuracy: Inside each converter micro-controller, the duty cycle is generated digitally, making for excellent duty cycle matching between connected units. Some small duty cycle mismatch is caused by (well controlled) process variations in the MOSFET gate drivers. However, the voltage difference induced by this duty cycle mismatch appears across the impedance of the entire power converter, from input to output, multiplied by two, since the differential current flows out of one converter and into another. So, a small duty cycle mismatch yields very small differential currents, which remain small even when 100 units are placed in parallel. In other current-sharing schemes, it is common to have a currentsharing control loop in each unit. However, due to the limited bandwidth of this loop, units do not necessarily share current on startup or during transients before this loop has a chance to respond. In contrast, the current-sharing scheme used in this product has no control dynamics: control signals are transmitted fast enough that the slave units can mirror the control state of the master unit on a cycle-by-cycle basis, and the current simply shares properly, from the first switching cycle to the last. www.synqor.com Doc.# 005-0005788 Rev. D 12/26/13 Page 14 Input: 35-75V Output: 28V Current: 21.5A Package: Half-brick Vin(+) Vout(+) Sense(+) On/Off ≥1 nF Elec. Cap. Share(+) Trim Load Share(-) Sense(-) Vin(-) Vout(-) Vin(+) Vout(+) Sense(+) On/Off Electrolytic Capacitor Share(+) Trim Share(-) Sense(-) Vin(-) Vout(-) Up to 100 Units Vin(+) On/Off Electrolytic Capacitor Vout(+) Sense(+) Share(+) Trim Share(-) Sense(-) Vin(-) Vout(-) Figure G: Typical Application Circuit for Paralleling of Full-Featured Units with an Output Common-Mode Choke. When using an output common-mode choke, SENSE lines must be connected on the module-side of the choke. See Figure F for configuration with an input common-mode choke. Product # PQ60280HZx22 Phone 1-888-567-9596 www.synqor.com Doc.# 005-0005788 Rev. D 12/26/13 Page 15 Technical Specification PQ60280HZx22 Ordering Information Part Numbering System Ordering Information The part numbering system for SynQor’s dc-dc converters follows the format shown in the example below. The tables below show the valid model numbers and ordering options for converters in this product family. When ordering SynQor converters, please ensure that you use the complete 15 character part number consisting of the 12 character base part number and the additional characters for options. Add “-G” to the model number for 6/6 RoHS compliance. PQ 6 0 2 8 0 H Z A 2 2 N R A - G 6/6 RoHS Options (see Ordering Information) Model Number Input Voltage PQ60280HZw22xyz-G 35-75V Output Voltage 28V Max Output Current 21.5A Output Current Thermal Design The following options must be included in place of the w x y z spaces in the model numbers listed above. Performance Level Options Description: w x y z Thermal Design Enable Logic Pin Style Package Size Output Voltage A - Open Frame C - Encased D - Encased with NonThreaded Baseplate Input Voltage Product Family The first 12 characters comprise the base part number and the last 3 characters indicate available options. The “-G” suffix indicates 6/6 RoHS compliance. N - Negative P - Positive Feature Set K - 0.110" N - 0.145" A - Standard R - 0.180" F - Full Featured Y - 0.250" Not all combinations make valid part numbers, please contact SynQor for availability. See the Product Summary web page for more options. Application Notes A variety of application notes and technical white papers can be downloaded in pdf format from our website. RoHS Compliance: The EU led RoHS (Restriction of Hazardous Substances) Directive bans the use of Lead, Cadmium, Hexavalent Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor product is 6/6 RoHS compliant. For more information please refer to SynQor’s RoHS addendum available at our RoHS Compliance / Lead Free Initiative web page or e-mail us at [email protected]. PATENTS SynQor holds the following U.S. patents, one or more of which apply to each product listed in this document. Additional patent applications may be pending or filed in the future. Contact SynQor for further information and to order: Phone: Toll Free: Fax: E-mail: Web: Address: Product # PQ60280HZx22 978-849-0600 888-567-9596 978-849-0602 [email protected] www.synqor.com 155 Swanson Road Boxborough, MA 01719 USA Phone 1-888-567-9596 5,999,417 6,222,742 6,545,890 6,577,109 6,594,159 6,731,520 6,894,468 6,896,526 6,927,987 7,050,309 7,072,190 7,085,146 7,119,524 7,269,034 7,272,021 7,272,023 7,558,083 7,564,702 7,765,687 7,787,261 8,023,290 8,149,597 8,493,751 Warranty SynQor offers a three (3) year limited warranty. Complete warranty information is listed on our website or is available upon request from SynQor. Information furnished by SynQor is believed to be accurate and reliable. However, no responsibility is assumed by SynQor for its use, nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of SynQor. www.synqor.com Doc.# 005-0005788 Rev. D 12/26/13 Page 16