80A/144W

Technical
S pecification
PQ60018HPA80
48V in
1.8Vout
80Amp
2000Vdc
Half-brick
Input
Output
Current
Isolation
DC/DC Conver ter
Th e P Q600 18HPA 80 P owerQo r ™ P eta h alf-b rick con vert er
is a ne xt- gen er at io n, b oa rd - mou nt a bl e, is ol at ed , fixed s wit ch in g fr eq ue ncy DC /DC c on ver ter tha t u se s sy nc hr on ou s re cti fi ca tio n t o a ch iev e ext r emel y h igh con v ers io n effic ien cy . T he
p owe r di ss ip at ed b y t h e c on ve rt er is so l ow th a t a h ea ts in k
is no t r eq uir ed , whi ch s av es cos t , weigh t, h eigh t , a n d a pp l i c atio n effor t. Al l of the p ower a n d co ntr ol co mpo ne nts a re
mo u nt ed t o t he mu lt i- la y er P CB s ub s t ra t e wi th h igh -y iel d s ur fa ce mou n t tech no lo gy for ma ximu m rel ia bil ity . Th e P eta
s er ies c on ve rter s o ffer in du s try lea d ing ou tp ut cu rr en t fo r a
s t an d ar d “ ha lf -b ri ck ” mod ul e. T he Pe ta u n it s al s o fe at u re
a ctive cu r ren t sh ar in g for N+ 1 a n d p ar a ll el a p pl ica tion s.
RoHS compliant (see page 13 ).
Pr otection Features
Operational Features
• Ultra-high efficiency, >90% half load, >88% full load
• Delivers up to 80 amps of output current with minimal
derating - no heatsink required
• Wide input voltage range: 35V – 75V, with 100V
100ms input voltage transient capability
• Fixed frequency switching provides predictable EMI
performance
• Industry standard pin-out configuration
• Industry standard size: 2.3” x 2.4” (58.4 x 61.0mm)
• Total height only 0.43” (10.8mm), permits better airflow and smaller card pitch
• Total weight: 2.9 oz. (83 grams)
Safety Features
• 2000V, 30 MΩ input-to-output isolation
• UL 60950-1 recognized (US & Canada), basic insulation rating
• TUV certified to EN60950-1
• Meets 72/23/EEC and 93/68/EEC directives
• Meets UL94V-0 flammability requirements
Phone 1-888-567-9596
• Input under-voltage lockout disables converter at low
input voltage conditions
• Output current limit and short circuit protection
• Active back bias limit prevents damage to converter
from external load induced pre-bias
• Output over-voltage protection
• Thermal shutdown
Contr ol Features
Mechanical Features
Product # PQ60018HPA80
PQ60018HPA80 Module
www.synqor.com
• On/Off control referenced to input side (positive and
negative logic options are available)
• Remote sense for the output voltage compensates for
output distribution drops
• Output voltage trim permits custom voltages and voltage
margining
Optional Features
(full feature)
• Active current share for N+1 and parallel applications
• External Clock Synchronization pin for better EMI characteristics
• Startup Synchronization pin for more consistent start-up
sequence
Doc.# 005-2HP618K Rev. E
03/06/06
Page 1
Technical Specification
MECHANICAL
DIAGRAM
35-75 V
1.8 V
80 A
Half-brick
Input:
Output:
Current:
Package:
2.30
(58.4)
0.19
1.90
(4.8)
(48.3)
0.200
(5.08)
0.50
(12.7)
0.400
0.400
(10.16)
(10.16)
0.700
1.000
(25.40)
Top View
1.400
(35.56)
(17.78)
0.200 (5.08)
1.000
(25.40)
0.200 (5.08)
1.400
2.40
(35.56)
(61.0)
0.200
(5.08)
0.43
(10.8)
Bottom side
Clearance
Side View
See Note 10
0.047+/-0.005
(1.19+/-0.12)
Lowest
Component
0.145
Load Board
(3.68)
See Note 4
PIN DESIGNATIONS
NOTES
1) Pins 1-4, 7-9, A-B are 0.040” (1.02mm) diameter. with
0.080” (2.03mm) diameter standoff shoulders.
2) Pins 5-6, 10-11 are 0.080” (2.03 mm) diameter with
0.125” (3.18mm) diameter standoff shoulders.
3) Pins 3, A, & B only included in Full-Feature models.
4) Other pin extension lengths available. Recommended pin
length is 0.03” (0.76mm) greater than the PCB thickness.
5) All Pins: Material - Copper Alloy
Finish (5/6 RoHS) - Tin/Lead over Nickel plate
Finish (6/6 RoHS) - Tin over Nickel plate
6) Undimensioned components are shown for visual reference
only.
7) All dimensions in inches (mm)
Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm)
x.xxx +/-0.010 in. (x.xx +/-0.25mm)
8) Weight: 2.9 oz. (83 g) typical
9) Workmanship: Meets or exceeds IPC-A-610C Class II
10) UL/TUV standards require a clearance greater than 0.04”
(1.02mm) between input and output for Basic insulation. This
issue should be considered if any copper traces are on the top
side of the user’s board. Note that the ferrite cores are considered part of the input/primary circuit.
Pin No. Name
Function
1
Vin(+)
Positive input voltage
2
ON/OFF
TTL input to turn converter
on and off, referenced to
Vin(-), with internal pull up.
3
I share
Single wire parallel signal
4
Vin(-)
Negative input voltage
5
Vout(+)
Positive output voltage
6
Vout(-)
Negative output voltage
7
SENSE(-)
Return remote sense
8
TRIM
Output voltage trim
9
SENSE(+)
Positive remote sense
10
Vout(+)
Positive output voltage
11
Vout(-)
Negative output voltage
A
Clock Sync
Clock synchronization
B
Start Sync
Startup synchronization
Pins in Italics Shaded text are Optional
Product # PQ60018HPA80
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2HP618K Rev. E
03/06/06
Page 2
Input:
Output:
Current:
Package:
Technical Specification
35-75 V
1.8 V
80 A
Half-brick
PQ60018HPA80 ELECTRICAL CHARACTERISTICS
TA=25°C, airflow rate=300 LFM, Vin=48Vdc unless otherwise noted; full operating temperature range is -40°C to +100°C ambient
temperature with appropriate power derating. Specifications subject to change without notice.
Parameter
Min.
Typ.
Max.
Units
100
80
100
2000
100
125
18
18
V
V
V
V
°C
°C
V
V
Notes & Conditions
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Non-Operating
Operating
Operating Transient Protection
Isolation Voltage (input to output)
Operating Temperature
Storage Temperature
Voltage at ON/OFF input pin
Voltage at Clock Sync pin
INPUT CHARACTERISTICS
Operating Input Voltage Range
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Voltage Hysteresis
Maximum Input Current
No-Load Input Current
Disabled Input Current
Inrush Current Transient Rating
Response to Input Transient
Input Reflected Ripple Current
Input Terminal Ripple Current
Recommended Input Fuse
Input Filter Component Values (C1\L\C2)
Recommended External Input Capacitance
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Line
Over Load
Over Temperature
Total Output Voltage Range
Output Voltage Ripple and Noise1
Peak-to-Peak
RMS
Operating Output Current Range
Output DC Current-Limit Inception
Output DC Current-Limit Shutdown Voltage
Current Share Accuracy (2 units paralleled)
Back-Drive Current Limit while Enabled
Back-Drive Current Limit while Disabled
Maximum Output Capacitance
-40
-55
-2
-15
35
48
75
V
31.5
29.5
2.2
33.3
31.0
2.3
34.4
32.4
2.4
4.7
90
5
0.03
V
V
V
A
mA
mA
A 2s
mV
mA
mA
A
µF\µH\µF
µF
73
2
150
5
125
2\4\4
47
1.782
1.746
0
88
1.50
0
DYNAMIC CHARACTERISTICS
Input Voltage Ripple Rejection
Output Voltage during Load Current Transient
For a Step Change in Output Current (0.1A/µs)
For a Step Change in Output Current (5A/µs)
Settling Time
Turn-On Transient
Turn-On Time
Start-Up Inhibit Time
Output Voltage Overshoot
EFFICIENCY
100% Load
50% Load
16
180
1.800
20
1.818
+0.06 \ 1 +0.11 \ 2
+0.11 \ 2 +0.22 \ 4
+15
+30
1.854
100
20
0.75
+2
3.25
10
150
30
80
96
+5
5.00
50
50,000
100% Load, 35 Vin
1000V/ms input transient
RMS thru 10µH inductor; Figures 13 & 15
RMS; Figures 13 & 14
Fast blow external fuse recommended
Internal values, see Figure E
Typical ESR 0.1-0.2Ω, see Figure 13
V
%\mV
%\mV
mV
V
mV
mV
A
A
V
%
A
mA
µF
Over sample, line, load, temperature & life
20MHz bandwidth; Figures 13 & 16
Full Load, see Figures 13 & 16
Full Load, see Figures 13 & 16
Subject to thermal derating; Figures 5 - 8
Output Voltage 10% Low; Figure 17
% of rated output current
Negative current drawn from output
Negative current drawn from output
1.8Vout at 80A Resistive Load
dB
120 Hz; Figure 20
60
140
100
mV
mV
µs
50% to 75% to 50% Iout max; Figure 11
50% to 75% to 50% Iout max; Figure 12
To within 1% Vout nom
ms
ms
%
Full load, Vout=90% nom.; Figures 9 & 10
-40°C to +125°C; Figure A
10,000 µF load capacitance, Iout = 0A
%
%
Figures 1 - 4
Figures 1 - 4
°C
°C
°C
Package rated to 150°C
UL rated max operating temp 130°C
See Figures 5 - 8 for derating curves
20
200
0
TEMPERATURE LIMITS FOR POWER DERATING CURVES
Semiconductor Junction Temperature
Board Temperature
Transformer Temperature
Isolation Voltage (dielectric strength)
Isolation Resistance
Isolation Capacitance2
Applies to Full Feature option only
80
24
250
88.2
90.4
ISOLATION CHARACTERISTICS
Continuous
Continuous
100ms transient, square wave
Basic insulation level, Pollution degree 2
125
125
125
2000
30
3300
V
MΩ
pF
Note 1: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected])
Note 2: Higher values of isolation capacitance can be added external to the module.
Product # PQ60018HPA80
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2HP618K Rev. E
03/06/06
Page 3
Input:
Output:
Current:
Package:
Technical Specification
35-75 V
1.8 V
80 A
Half-brick
ELECTRICAL CHARACTERISTICS (Continued)
Parameter P
FEATURE CHARACTERISTICS
Switching Frequency
Isolation Stage Switching Frequency
ON/OFF Control (Option P)
Off-State Voltage
On-State Voltage
ON/OFF Control (Option N)
Off-State Voltage
On-State Voltage
ON/OFF Control (Either Option)
Pull-Up Voltage
Pull-Up Resistance
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
Over-Temperature Shutdown
Over-Temperature Shutdown Restart Hysteresis
Load Current Scale Factor
Min.
Typ.
Max.
Units
190
210
100
230
kHz
kHz
-2
2.7
0.8
18
V
V
2.7
-2
18
0.8
V
V
15
V
kΩ
%
%
%
°C
°C
-20
122
Vin/6
42
127
125
10
2950
RELIABILITY CHARACTERISTICS
Calculated MTBF (Telcordia)
Calculated MTBF (MIL-217)
Field Demonstrated MTBF
+10
+10
132
Notes & Conditions
Figures A & B
Measured across Pins 10 & 5; Figure C
Measured across Pins 10 & 5
Over full temp range; % of nominal Vout
Average PCB Temperature
See App Note: Output Load Current Calc.
10 Hrs. TR-NWT-000332; 75% load,300LFM, 40oC Ta
106 Hrs. MIL-HDBK-217F; 75% load, 300LFM, 40oC Ta
106 Hrs. See our website for details
6
2.16
1.43
STANDARDS COMPLIANCE
Parameter P
Notes
STANDARDS COMPLIANCE
UL/cUL 60950-1
EN60950-1
72/23/EEC
93/68/EEC
Needle Flame Test (IEC 695-2-2)
IEC 61000-4-2
GR-1089-CORE
Telcordia (Bellcore) GR-513
File # E194341, Basic insulation & pollution degree 2
Certified by TUV
Test on entire assembly; board & plastic components UL94V-0 compliant
ESD test, 8kV - NP, 15kV air - NP (Normal Performance)
Section 7 - electrical safety, Section 9 - bonding/grounding
• An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety
certificates on new releases or download from the SynQor website.
QUALIFICATION TESTING
Parameter P
QUALIFICATION TESTING
Life Test
Vibration
Mechanical Shock
Temperature Cycling
Power/Thermal Cycling
Design Marginality
Humidity
Solderability
# Units
32
5
5
10
5
5
5
15 pins
Test Conditions
95% rated Vin and load, units at derating point, 1000 hours
10-55Hz sweep, 0.060” total excursion,1 min./sweep, 120 sweeps for 3 axis
100g minimum, 2 drops in x and y axis, 1 drop in z axis
-40°C to 100°C, unit temp. ramp 15°C/min., 500 cycles
Toperating = min to max, Vin = min to max, full load, 100 cycles
Tmin-10°C to Tmax+10°C, 5°C steps, Vin = min to max, 0-105% load
85°C, 85% RH, 1000 hours, 2 minutes on and 6 hours off
MIL-STD-883, method 2003
• Extensive characterization testing of all SynQor products and manufacturing processes is performed to ensure that we supply
robust, reliable product. Contact the factory for official product family qualification documents.
OPTIONS
PATENTS
SynQor provides various options for Logic Sense, Pin Length and
Feature Set for this family of DC/DC converters. Please consult the
last page of this specification sheet for information on available
options.
SynQor is protected under various patents, including but not limited to U.S. Patent #s 5,999,417; 6,222,742 B1; 6,594,159
B2; 6,545,890 B2.
Product # PQ60018HPA80
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2HP618K Rev. E
03/06/06
Page 4
Input:
Output:
Current:
Package:
Technical Specification
35-75 V
1.8 V
80 A
Half-brick
94
95
93
90
Efficiency (%)
Efficiency (%)
92
85
80
75
91
90
89
88
25 C
40 C
35 Vin
70
87
48 Vin
75 Vin
0
8
16
24
32
40
48
56
64
72
55 C
86
65
0
80
100
24
12
20
11
16
12
8
35 Vin
4
75 Vin
24
32
40
48
500
56
64
72
10
9
8
25 C
40 C
55 C
6
0
16
400
7
48 Vin
8
300
Figure 2: Efficiency at nominal output voltage and 60% rated power vs.
airflow rate for ambient air temperatures of 25°C, 40°C, and 55°C
(nominal input voltage).
Power Dissipation (W)
Power Dissipation (W)
Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25°C.
0
200
Air Flow (LFM)
Load Current (A)
0
80
100
200
300
400
500
Air Flow (LFM)
Load Current (A)
Figure 3: Power dissipation at nominal output voltage vs. load current
for minimum, nominal, and maximum input voltage at 25°C.
Figure 4: Power dissipation at nominal output voltage and 60% rated
power vs. airflow rate for ambient air temperatures of 25°C, 40°C, and
55°C (nominal input voltage).
80
Iout (A)
70
60
50
400 LFM (2.0 m/s)
300 LFM (1.5 m/s)
40
200 LFM (1.0 m/s)
100 LFM (0.5 m/s)
30
0
25
40
55
70
85
Ambient Air Temperature (ºC)
Figure 5: Maximum output power derating curves vs. ambient air temperature for airflow rates of 0 LFM through 400 LFM with air flowing
from input to output (nominal input voltage).
Product # PQ60018HPA80
Phone 1-888-567-9596
Figure 6: Thermal plot of converter at 80 amp load current with 55°C
air flowing at the rate of 200 LFM. Air is flowing across the converter
from input to output (nominal input voltage).
www.synqor.com
Doc.# 005-2HP618K Rev. E
03/06/06
Page 5
Input:
Output:
Current:
Package:
Technical Specification
35-75 V
1.8 V
80 A
Half-brick
80
70
60
Iout (A)
50
40
30
400 LFM (2.0 m/s)
20
300 LFM (1.5 m/s)
200 LFM (1.0 m/s)
10
100 LFM (0.5 m/s)
0
0
25
40
55
70
85
Ambient Air Temperature (ºC)
Figure 7: Maximum output power derating curves vs. ambient air temperature for airflow rates of 0 LFM through 400 LFM with air flowing
from output to input (nominal input voltage).
Figure 8: Thermal plot of converter at 78 amp load current with 55°C
air flowing at the rate of 200 LFM. Air is flowing across the converter
from output to input (nominal input voltage).
Figure 9: Turn-on transient at full load (resistive load) (10 ms/div).
Input voltage pre-applied. Top Trace: Vout (500mV/div). Bottom
Trace: ON/OFF input (5V/div)
Figure 10: Turn-on transient at zero load (10 ms/div).
Top Trace: Vout (500mV/div)
Bottom Trace: ON/OFF input (5V/div)
Figure 11: Output voltage response to step-change in load current (50%-75%-50%
of Iout(max); dI/dt = 0.1A/µs). Load cap: 15µF, 450 mΩ ESR tantalum capacitor and
Figure 12: Output voltage response to step-change in load current (50%-75%-50%
of Iout(max): dI/dt = 5A/µs). Load cap: 480µF, 15 mΩ ESR tantalum capacitor and
1µF ceramic capacitor. Top trace: Vout (100mV/div), Bottom trace: Iout (20A/div).
1µF ceramic capacitor. Top trace: Vout (200mV/div), Bottom trace: Iout (20A/div).
Product # PQ60018HPA80
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2HP618K Rev. E
03/06/06
Page 6
Input:
Output:
Current:
Package:
Technical Specification
35-75 V
1.8 V
80 A
Half-brick
See Fig. 15
10 µH
See Fig. 14
source
impedance
See Fig. 16
iS
iC
VSOURCE
DC/DC
Converter
VOUT
15 µF,
1 µF
47 µF,
<1Ω ESR
ceramic 450mΩ ESR
capacitor
tantalum
capacitor
electrolytic
capacitor
Figure 13: Test set-up diagram showing measurement points for Input
Terminal Ripple Current (Figure 14), Input Reflected Ripple Current
(Figure 15) and Output Voltage Ripple (Figure 16).
Figure 14: Input Terminal Ripple Current, ic, at full rated output current and nominal input voltage with 10µ H source impedance and 47µ F
electrolytic capacitor (200 mA/div). (See Figure 13)
Figure 15: Input reflected ripple current, is, through a 10 µ H source
inductor at nominal input voltage and rated load current (5 mA/div).
(See Figure 13)
Figure 16: Output voltage ripple at nominal input voltage and rated
load current (100 mV/div). Load capacitance: 1µ F ceramic capacitor
and 15µ F tantalum capacitor. Bandwidth: 20 MHz. (See Figure 13)
2.0
1.8
Output Voltage (V)
1.6
1.4
1.2
1.0
0.8
0.6
35 V
0.4
48 V
0.2
75 V
0.0
0
10
20
30
40
50
60
70
80
90
100
110
Load Current (A)
Figure 17: Output voltage vs. load current showing typical current limit
curves and converter shutdown points.
Product # PQ60018HPA80
Phone 1-888-567-9596
Figure 18: Load current (50A/div) as a function of time when the converter attempts to turn on into a 1 mΩ short circuit. Top trace
(2.5ms/div) is an expansion of the on-time portion of the bottom trace.
www.synqor.com
Doc.# 005-2HP618K Rev. E
03/06/06
Page 7
Input:
Output:
Current:
Package:
Technical Specification
35-75 V
1.8 V
80 A
Half-brick
-10
0.01
35 Vin
0.001
48 Vin
75 Vin
Forward Transmission (dB)
Output Impedance (Ω
Ω)
-20
-30
-40
35 Vin
-50
48 Vin
75 Vin
-60
-70
-80
-90
0.0001
1,000
100
10,000
100
100,000
1,000
10,000
100,000
Hz
Hz
Figure 19: Magnitude of incremental output impedance (Zout =
vout/iout) for minimum, nominal, and maximum input voltage at full
rated power.
Figure 20: Magnitude of incremental forward transmission (FT =
vout/vin) for minimum, nominal, and maximum input voltage at full
rated power.
0
100
-10
-15
-20
35 Vin
-25
48 Vin
-30
75 Vin
-35
Input Impedance (Ω
Ω)
Reverse Transmission (dB)
-5
10
35 Vin
48 Vin
75 Vin
1
-40
-45
-50
0.1
10
100
1,000
10,000
100,000
10
Hz
Figure 21: Magnitude of incremental reverse transmission (RT =
iin/iout) for minimum, nominal, and maximum input voltage at full rated
power.
100
1,000
Hz
10,000
100,000
Figure 22: Magnitude of incremental input impedance (Zin = vin/iin)
for minimum, nominal, and maximum input voltage at full rated power.
10
9
Vout Trim-up (%)
8
7
6
5
4
3
2
100% Load
50% Load
1
0% Load
0
40.0
39.5
39.0
38.5
38.0
37.5
37.0
36.5
36.0
35.5
35.0
Input Voltage (V)
Figure 23: Achievable trim-up percentage vs. input voltage. at output
loads of 0%, 50% and full load.
Product # PQ60018HPA80
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2HP618K Rev. E
03/06/06
Page 8
Input:
Output:
Current:
Package:
Technical Specification
35-75 V
1.8 V
80 A
Half-brick
BASIC OPERATION AND FEATURES
CONTROL FEATURES
The PowerQor series converter uses a two-stage power conversion topology. The first stage is a buck-converter that keeps the
output voltage constant over variations in line, load, and temperature. The second stage uses a transformer to provide the functions of input/output isolation and voltage step-down to achieve
the low output voltage required.
REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits
the user to control when the converter is on or off. This input is
referenced to the return terminal of the input bus, Vin(-). There are
two versions of the converter that differ by the sense of the logic
used for the ON/OFF input.
Both the first stage and the second stage switch at a fixed frequency for predictable EMI performance. Rectification of the
transformer’s output is accomplished with synchronous rectifiers.
These devices, which are MOSFETs with a very low on-state resistance, dissipate far less energy than Schottky diodes. This is the
primary reason that the PowerQor converter has such high efficiency, even at very low output voltages and very high output currents.
Dissipation throughout the converter is so low that it does not
require a heatsink for operation. Since a heatsink is not required,
the PowerQor converter does not need a metal baseplate or potting material to help conduct the dissipated energy to the
heatsink. The PowerQor converter can thus be built more simply
and reliably using high yield surface mount techniques on a PCB
substrate.
The PowerQor series of half-brick, quarter-brick and eighth-brick
converters uses the industry standard footprint and pin-out configuration.
In the positive logic version, the ON/OFF input is active high
(meaning that a high turns the converter on). In the negative logic
version, the ON/OFF signal is active low (meaning that a low
turns the converter on). Figure A details five possible circuits for
driving the ON/OFF pin. Figure B is a detailed look of the internal ON/OFF circuitry.
REMOTE SENSE(+) (Pins 9 and 7): The SENSE(+) inputs correct for voltage drops along the conductors that connect the converter’s output pins to the load.
Pin 9 should be connected to Vout(+) and Pin 7 should be connected to Vout(-) at the point on the board where regulation is
desired. A remote connection at the load can adjust for a voltage
drop only as large as that specified in this datasheet, that is
[Vout(+) - Vout(-)] – [Vsense(+) - Vsense(-)] <
Sense Range % x Vout
Pins 9 and 7 must be connected for proper regulation of the output voltage. If these connections are not made, the converter will
deliver an output voltage that is slightly higher than its specified
value.
Note: the output over-voltage protection circuit senses the voltage
ON/OFF
ON/OFF
ON/OFF
Vin(_)
Vin(_)
Vin(_)
Remote Enable Circuit
Negative Logic
(Permanently Enabled)
ON/OFF
Positive Logic
(Permanently Enabled)
5V
Vin(+)
5V
274k
ON/OFF
50k
TTL
TTL/
CMOS
ON/OFF
Vin(_)
Vin(_)
Open Collector Enable Circuit
Vin(_)
Direct Logic Drive
Figure A: Various circuits for driving the ON/OFF pin.
Product # PQ60018HPA80
100pF
50k
Phone 1-888-567-9596
www.synqor.com
Figure B: Internal ON/OFF pin circuitry
Doc.# 005-2HP618K Rev. E
03/06/06
Page 9
Input:
Output:
Current:
Package:
Technical Specification
across the output (pins 11 and 5) to determine when it should
trigger, not the voltage across the converter’s sense leads (pins 9
and 7). Therefore, the resistive drop on the board should be
small enough so that output OVP does not trigger, even during
load transients.
OUTPUT VOLTAGE TRIM (Pin 8): The TRIM input permits the
user to adjust the output voltage across the sense leads up or
down according to the trim range specifications.
To decrease the output voltage, the user should connect a resistor
between Pin 8 and Pin 7 (SENSE(-) input). For a desired decrease
of the nominal output voltage, the value of the resistor should be
100%
Rtrim-down =
- 2 (kΩ)
∆
(
)
where
∆% =
Vnominal – Vdesired
Vnominal
x 100%
To increase the output voltage, the user should connect a resistor
between Pin 8 and Pin 9 (SENSE(+) input). For a desired increase
of the nominal output voltage, the value of the resistor should be
Rtrim-up =
(
Vnominal – 2
x VDES + VNOM
1.225
)
VDES - VNOM
(kΩ)
Figure C graphs the relationship between the trim resistor value
and Rtrim-up and Rtrim-down, showing the total range the output
voltage can be trimmed up or down.
cuit to engage, particularly during transients.
It is not necessary for the user to add capacitance at the Trim pin.
The node is internally bypassed to eliminate noise.
Total DC Variation of Vout: For the converter to meet its full
specifications, the maximum variation of the DC value of Vout,
due to both trimming and remote load voltage drops, should not
be greater than that specified for the output voltage trim range.
PROTECTION FEATURES
Input Under-Voltage Lockout: The converter is designed to
turn off when the input voltage is too low, helping avoid an input
system instability problem, described in more detail in the application note titled “Input System Instability”. The lockout circuitry
is a comparator with DC hysteresis. When the input voltage is rising, it must exceed the typical Turn-On Voltage Threshold value
(listed on the specification page) before the converter will turn
on. Once the converter is on, the input voltage must fall below
the typical Turn-Off Voltage Threshold value before the converter
will turn off.
Input Over-Voltage Shutdown: Available on PQ48 models
only. The converter turns off when the input voltage is too high,
allowing the converter to withstand an input voltage as high as
100V without destruction. The shutdown circuitry is a comparator with DC hysteresis. When the input voltage exceeds the typical Input Over-Voltage Shutdown value, the converter will turn off.
Once the converter is off, it will turn back on when the input voltage falls below the minimum Input Over-Voltage Shutdown value.
Output Current Limit: The maximum current limit remains constant as the output voltage drops. However, once the impedance
of the short across the output is small enough to make the output
voltage drop below the specified Output DC Current-Limit
Shutdown Voltage, the converter turns off.
1,000
Trim Resistance (kOhms)
35-75 V
1.8 V
80 A
Half-brick
100
The converter then enters a “hiccup mode” where it repeatedly
turns on and off at a 5 Hz (nominal) frequency with a 5% duty
cycle until the short circuit condition is removed. This prevents
excessive heating of the converter or the load board.
10
1
0
2
4
6
8
10
% Increase in Vout
12
14
16
18
20
% Decrease in Vout
Figure C: Trim Graph for 1.8Vout module
Note: the TRIM feature does not affect the voltage at which the
output over-voltage protection circuit is triggered. Trimming the
output voltage too high may cause the over-voltage protection cirProduct # PQ60018HPA80
Phone 1-888-567-9596
Output Over-Voltage Limit: If the voltage across the output
pins exceeds the Output Over-Voltage Protection threshold, the
converter will immediately stop switching. This prevents damage
to the load circuit due to 1) excessive series resistance in output
current path from converter output pins to sense point, 2) a
release of a short-circuit condition, or 3) a release of a current
limit condition. Load capacitance determines exactly how high
the output voltage will rise in response to these conditions. After
200 ms the converter will automatically restart.
www.synqor.com
Doc.# 005-2HP618K Rev. E
03/06/06
Page 10
Input:
Output:
Current:
Package:
Technical Specification
Over-Temperature Shutdown: A temperature sensor on the
converter senses the average temperature of the module. The
thermal shutdown circuit is designed to turn the converter off
when the temperature at the sensed location reaches the OverTemperature Shutdown value. It will allow the converter to turn on
again when the temperature of the sensed location falls by the
amount of the Over-Temperature Shutdown Restart Hysteresis
value.
35-75 V
1.8 V
80 A
Half-brick
trolytic input capacitor. The recommended external input capacitance is specified in the “Input Characteristics” section. More
detailed information is available in the application note titled
“EMI Characteristics” on the SynQor website.
APPLICATION CONSIDERATIONS
Input System Instability: This condition can occur because
any DC/DC converter appears incrementally as a negative
resistance load. A detailed application note titled “Input
System Instability” is available on the SynQor website which
provides an understanding of why this instability arises, and
shows the preferred solution for correcting it.
Application Circuits: Figure D below provides a typical circuit diagram which details the input filtering and voltage trimming.
Input Filtering and External Capacitance: Figure E below
provides a diagram showing the internal input filter components.
This filter dramatically reduces input terminal ripple current,
which otherwise could exceed the rating of an external elec-
Vin(+)
Vin
External
Input
Filter
Electrolytic
Capacitor
47µF
Vout(+)
Vsense(+)
ON/OFF
Trim
Vsense(_)
Vin(_)
Rtrim-up
or
Rtrim-down
Cload
Iload
Vout(_)
Figure D: Typical application circuit (negative logic unit, permanently enabled).
L
Vin(+)
C1
C2
Vin(_)
Figure E: Internal Input Filter Diagram (component values listed on page 3).
Product # PQ60018HPA80
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2HP618K Rev. E
03/06/06
Page 11
Input:
Output:
Current:
Package:
Technical Specification
Startup Inhibit Period: The Startup Inhibit Period ensures that
the converter will remain off for approximately 200ms when it is
shut down for any reason. When an output short is present, this
generates a 5Hz "hiccup mode," which prevents the converter
from overheating. In all, there are seven ways that the converter
can be shut down, initiating a Startup Inhibit Period:
35-75 V
1.8 V
80 A
Half-brick
When the ON/OFF pin goes high after t2, the Startup Inhibit
Period has elapsed, and the output turns on within the typical
Turn-On Time.
FULL FEATURE APPLICATION NOTES
This section provides some basic application information for the
full-feature version of the PowerQor series converter. The pin-out
configuration for these optional feature pins is shown on page 2,
and the part numbering format is shown on the last page of this
specification sheet.
• Input Under-Voltage Lockout
• Input Over-Voltage Shutdown (not present in Quarter-brick)
• Output Over-Voltage Protection
• Over Temperature Shutdown
• Current Limit
• Short Circuit Protection
• Turned off by the ON/OFF input
Figure F shows three turn-on scenarios, where a Startup Inhibit
Period is initiated at t0, t1, and t2:
Before time t0, when the input voltage is below the UVL threshold,
the unit is disabled by the Input Under-Voltage Lockout feature.
When the input voltage rises above the UVL threshold, the Input
Under-Voltage Lockout is released, and a Startup Inhibit Period is
initiated. At the end of this delay, the ON/OFF pin is evaluated,
and since it is active, the unit turns on.
At time t1, the unit is disabled by the ON/OFF pin, and it cannot
be enabled again until the Startup Inhibit Period has elapsed.
All units in this product family include back-drive protection to
simplify the use of multiple converters in a parallel or sequencing
application. However, any voltage applied to the output of the
converter should be kept below 120% of the rated output voltage
of the converter.
In addition to back-drive protection, these units include the following features (pins):
Current Share (pin 3): The active current share feature allows
for N+1 and parallel applications. To achieve load sharing,
directly connect the I share pins of multiple units. The load current
will share equally among the multiple units (±5% at full rated current). It is important that the Vin(-) pins of the sharing units be
directly connected and NOT placed outside of an EMI filter or
other impedance path. The voltage at the I Share pin will range
from 0 to 5 volts (at full rated current), referenced to the primaryside ground, Vin(-).
Vin
Under-Voltage
Lockout Turn-On
Threshold
ON/OFF
(pos logic)
ON
OFF ON
OFF
ON
20ms (typical
Vout
turn on time)
200ms
(typical start-up
inhibit period)
t1
t0
200ms
200ms
t2
t
Figure F: Startup Inhibit Period (turn-on time not to scale)
Product # PQ60018HPA80
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2HP618K Rev. E
03/06/06
Page 12
Input:
Output:
Current:
Package:
Technical Specification
Start Sync (pin B): The Start Synchronization pin will allow a
more consistent start-up sequence. To operate this feature, connect together the Start-Sync pins of multiple current-sharing units.
This will permit immediate start-up with loads greater than the current limit of a single unit. Without this connection, any set of converters attempting to asynchronously start (or re-start) with a load
greater than the current limit of a single unit will "hiccup". This
“hiccup” mode will continue until one converter attempts a start
at the same time as the minimum number of additional units necessary to sustain the load condition. For example, three 50 amp
units starting into a 90 amp load would require two units to simultaneously attempt a start. The Start Sync connection synchronizes these starting attempts and provides a more consistent and
reliable start-up sequence. For details about the "hiccup mode"
or repeated startup attempts, please see the "Startup Inhibit
Period" note in this Technical Specification.
35-75 V
1.8 V
80 A
Half-brick
RoHS Compliance: The EU led RoHS (Restriction of Hazardous
Substances) Directive bans the use of Lead, Cadmium,
Hexavalent Chromium, Mercury, Polybrominated Biphenyls
(PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical
and Electronic Equipment. This SynQor product is available as
5/6 RoHS compliant (product with lead) or 6/6 RoHS compliant.
For more information please refer to SynQor’s RoHS addendum
available at our RoHS Compliance / Lead Free Initiative web
page or e-mail us at [email protected].
Clock Sync (pin A): The External Clock Synchronization pin
provides the ability for the user to control the EMI signature and
synchronize sensitive circuitry to quiet periods in the converter
operation. With this option, the converter can be synchronized to
an external clock signal whose frequency is greater than that of
the free-running internal clock. However, substantially raising the
converter’s frequency will reduce its efficiency. Therefore, the recommended frequency range for the external clock synchronization signal applied to this pin would be the lowest value possible
without dropping below the maximum switching frequency value
listed on the Electrical Specifications page.
The following requirements should also be met:
• The external clock signal should be referenced to the
negative input voltage, Vin(-).
• The high level of the signal should be between 3.5V and
5.0V.
• The low level should be between -0.5V and +1.2V.
• Do not apply a clock signal lower than the specified frequency.
Product # PQ60018HPA80
Phone 1-888-567-9596
www.synqor.com
Doc.# 005-2HP618K Rev. E
03/06/06
Page 13
Input:
Output:
Current:
Package:
Technical Specification
35-75 V
1.8 V
80 A
Half-brick
PART NUMBERING SYSTEM
ORDERING INFORMATION
The part numbering system for SynQor’s PowerQor DC/DC
converters follows the format shown in the example below.
The tables below show the valid model numbers and ordering
options for converters in this product family. When ordering
SynQor converters, please ensure that you use the complete
15 character part number consisting of the 12 character base
part number and the additional 3 characters for options.
PQ 60 018 H P A 80 N K S
Options (see
Ordering Information)
Output Current
Thermal Design
Performance Level
Package Size
Output Voltage
Input Voltage
Product Family
The first 12 characters comprise the base part number and the
last 3 characters indicate available options. Although there
are no default values for enable logic and pin length, the most
common options are negative logic and 0.145” pins. These
part numbers are more likely to be readily available in stock
for evaluation and prototype quantities.
Model Number
Input Voltage
PQ60012HPAA0xyz
PQ60015HPAA0xyz
PQ60018HPAA0xyz
PQ60018HPA80xyz
PQ60025HPA80xyz
PQ60033HPA70xyz
PQ60050HPA45xyz
PQ60120HPA20xyz
35 - 75 V
35 - 75 V
35 - 75 V
35 - 75 V
35 - 75 V
35 - 75 V
35 - 75 V
35 - 75 V
Output Max Output
Voltage Current
1.2 V
100 A
1.5 V
100 A
1.8 V
100 A
1.8 V
80 A
2.5 V
80 A
3.3 V
70 A
5.0 V
45 A
12 V
20 A
The following option choices must be included in place of the
x y z spaces in the model numbers listed above. To order 6/6
RoHS compliant product please add a “-G” suffix. For more
information please refer to SynQor’s RoHS addendum available
at our RoHS Compliance / Lead Free Initiative web page or email us at [email protected].
Options Description: x y z
Enable
Logic
Application Notes
Pin
Length
Feature
Set
K - 0.110"
S - Standard
P - Positive N - 0.145"
F - Full Feature
N - Negative R - 0.180"
(1.2-1.8V only)
Y - 0.250"
A variety of application notes and technical white papers can
be downloaded in pdf format from our website.
Contact SynQor for further information:
Phone:
Toll Free:
Fax:
E-mail:
Web:
Address:
Product # PQ60018HPA80
978-849-0600
888-567-9596
978-849-0602
[email protected]
www.synqor.com
155 Swanson Road
Boxborough, MA 01719
USA
Phone 1-888-567-9596
Warranty
SynQor offers a three (3) year limited warranty. Complete warranty
information is listed on our website or is available upon request from
SynQor.
Information furnished by SynQor is believed to be accurate and reliable.
However, no responsibility is assumed by SynQor for its use, nor for any
infringements of patents or other rights of third parties which may result
from its use. No license is granted by implication or otherwise under any
patent or patent rights of SynQor.
www.synqor.com
Doc.# 005-2HP618K Rev. E
03/06/06
Page 14