Technical Specification BQ57120QEx50 52.5 V 9.3-16.25 V 50 A 630 W 2000 V dc Quarter-brick Input Output Current Power Isolation DC-DC Converter ® The BusQor® BQ57120QEx50 bus converter is a nextgeneration, board-mountable, isolated, fixed switching frequency DC/DC converter that uses synchronous rectification to achieve extremely high conversion efficiency. The power dissipated by the converter is so low that a heatsink is not required, which saves cost, weight, height, and application effort. The BusQor series provides an isolated step down voltage from 52.5 V to 13.1 V intermediate bus with no regulation in a standard quarter-brick module. BusQor converters are ideal for creating the mid-bus voltage required to drive point-of-load (non-isolated) converters in intermediate bus architectures. BQ57120QEx50 Model Operational Features • • • • • Mechanical Features High efficiency, 96.25% at full rated load current Delivers 50 A full power with minimal derating - no heatsink required Operating input voltage range: 40-65 V Fixed frequency switching provides predictable EMI No minimum load requirement • Industry standard quarter-brick pin-out configuration • Size: 1.45” x 2.3” (36.8 x 58.4 mm), 0.467” (11.86 mm) • Open frame weight: 1.5 oz (42 g) Protection Features Control Features • On/Off control referenced to input side (positive and negative logic options are available) • Inherent current share (by droop method) for high current and parallel applications. • Input under-voltage lockout and over-voltage shutdown protects against abnormal input voltages • Output current limit and short circuit protection (auto recovery) • Output over-voltage protection • Thermal shutdown Contents Page No. Safety Features • UL 60950-1/R2011-12 • EN60950-1/A2:2013 • CAN/CSA-C22.2 No. 60950-1/A1:2011 Product # BQ57120QEx50 Phone 1-888-567-9596 Open Frame Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Baseplated Mechanical Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Compliance & Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Technical Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Applications Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 www.synqor.com Doc.# 005-0006201 Rev. C 07/21/15 Page 1 Input: 40-65 V Output: 9.3-16.25 V Current: 50A Package: Quarter-brick Open Frame Mechanical Diagram 1.450 [ 36.83] .600 [15.24 ] 5 .467 ±.020 [ 11.86 ±0.5] OVERALL HEIGHT 4 .056 ±.010 [ 1.42 ±0.25 ] BOTTOMSIDE CLEARANCE 2.300 [ 58.42 ] 2.000 [ 50.8 ] .143 [ 3.63 ] 1 2 3 .425 [ 10.8 ] .110 [ 2.79 ] SEE NOTE 3 .300 [ 7.62 ] .600 [ 15.24 ] NOTES PIN DESIGNATIONS 1) Pins 1-3 are 0.040” (1.02mm) diameter with 0.080” (2.03 mm) diameter standoff shoulders. 2) Pins 4-5 are 0.062” (1.57 mm) diameter with 0.100” (2.54 mm) diameter standoff shoulders. 3) Other pin lengths available. Recommended pin length is 0.03” (0.76mm) greater than the PCB thickness. 4) All Pins: Material - Copper Alloy Finish: Matte Tin over Nickel plate 5) Undimensioned components are shown for visual reference only. 6) All dimensions in inches (mm) 7) Tolerances: x.xx +/-0.02 in. (x.x +/-0.5mm) x.xxx +/-0.010 in. (x.xx +/-0.25mm) Weight: 1.5 oz (42 g) typical 8) Workmanship: Meets or exceeds IPC-A-610C Class II 9) UL/TUV standards require a clearance of 0.04” (1.02mm) around primary areas of the module. 10) The flanged pins are designed to permit surface mount soldering (allowing to avoid the wave soldering process) through the use of the flanged pin-in-paste technique. Product # BQ57120QEx50 Phone 1-888-567-9596 Pin Name Function 1 Vin(+) Positive input voltage 2 ON/OFF Logic control input to turn converter on/off. 3 Vin(–) Negative input 4 Vout(–) Negative output 5 Vout(+) Positive output www.synqor.com Doc.# 005-0006201 Rev. C 07/21/15 Page 2 Input: 40-65 V Output: 9.3-16.25 V Current: 50A Package: Quarter-brick Baseplated Mechanical Diagram 1.510[38.35] .517±.030 [ 13.13±0.76 ] OVERALL HEIGHT 1.100[27.94] .600 [15.24] .053±.030 [ 1.35±0.76 ] BOTTOMSIDE CLEARANCE 4 5 2.340 [59.44] 1.900 [48.26] 2.000 [50.8] .750 [19.05] 1 2 3 .060 [1.52] .160±.015 [4.06±0.38] .455±.0151 [1.56±0.38] .110 [2.79] SEE NOTE 4 M3 INSERTS (3 PLACES) (SEE NOTES 1&2 .300[7.62] .600[15.24] .850[21.59] NOTES 1) M3 screws used to bolt unit's baseplate to other surfaces such as heatsinks must not exceed 0.10" (2.54mm) depth below the surface of the baseplate. 2) Applied torque per screw should not exceed 6in-lb (0.7Nm) 3) Baseplate flatness tolerance is 0.004" (.10mm) TIR for surface 4) Other pin extension lengths available 5) Pins 1-3 are 0.040" (1.02mm) dia. with 0.080" (2.03mm) dia. standoff shoulders 6) Pins 4 and 5 are 0.062" (1.57mm) dia. with 0.100" (2.54mm) dia. standoff shoulders 7) All pins: Material: Copper Alloy Finish: Matte Tin over Nickel plate 8) Undimensioned components are shown for visual reference only 9) Weight: 2.7 oz (78 g) typical 10) All dimensions in inches(mm) Tolerances: x.xxin +/-0.02 (x.xmm +/-0.5mm) x.xxxin +/-0.010 (x.xxmm +/-0.25mm) Product # BQ57120QEx50 Phone 1-888-567-9596 PIN DESIGNATIONS Pin Name Function 1 Vin(+) Positive input voltage 2 ON/OFF Logic control input to turn converter on/off. 3 Vin(–) Negative input 4 Vout(–) Negative output 5 Vout(+) Positive output www.synqor.com Doc.# 005-0006201 Rev. C 07/21/15 Page 3 Input: 40-65 V Output: 9.3-16.25 V Current: 50A Package: Quarter-brick Technical Specification BQ57120QEx50 Electrical Characteristics Ta = 25 °C, airflow rate = 300 LFM, Vin = 52.5 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C ambient temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. ABSOLUTE MAXIMUM RATINGS Input Voltage Non-Operating Operating Isolation Voltage Input to Output Operating Temperature Storage Temperature Voltage at ON/OFF input pin INPUT CHARACTERISTICS Operating Input Voltage Range Input Under-Voltage Lockout Turn-On Voltage Threshold Turn-Off Voltage Threshold Lockout Voltage Hysteresis Input Over-Voltage Shutdown Turn-On Voltage Threshold Turn-Off Voltage Threshold Maximum Input Current No-Load Input Current Disabled Input Current Input Reflected-Ripple Current Input Terminal-Ripple Current Recommended Input Fuse (see Note 1) Recommended External Input Capacitance Input Filter Component Values (L\C) OUTPUT CHARACTERISTICS Output Voltage Set Point Output Voltage Regulation Over Line Over Load Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception Output DC Current-Limit Shutdown Voltage Back-Drive Current Limit while Disabled Maximum Output Capacitance EFFICIENCY 100% Load 50% Load Product # BQ57120QEx50 Typ. Max. Units Notes & Conditions -1 40 75 65 V V -40 -45 -2 2000 100 125 18 V °C °C V 65 V 40 52.5 38.4 35.8 2.6 66.3 68.5 8.5 25 550 17 160 12.0 50 20 47 0.47\11 µH\µF 13.12 V 48\6.25 4.6\600 1.6\200 %\V %\mV %\mV V 9.30 Phone 1-888-567-9596 V V V V V V A mA mA mA mA A µF 16.25 110 40 0 180 50 mV mV A 5,000 A V mA µF 63 9 10 96.3 96.6 www.synqor.com Continuous Continuous RMS through 10 µH inductor RMS, full load Fast blow external fuse recommended Typical ESR 0.1-0.2 Ω Internal values Over sample, line, load, temperature & life 20 MHz bandwidth; see Note 2 Full load Full load Subject to thermal derating Output Voltage 10% Low Negative current drawn from output 10.5 Vout at 30 A Resistive Load % % Doc.# 005-0006201 Rev. C 07/21/15 Page 4 Input: 40-65 V Output: 9.3-16.25 V Current: 50A Package: Quarter-brick Technical Specification BQ57120QEx50 Electrical Characteristics (continued) Ta = 25 °C, airflow rate = 300 LFM, Vin = 52.5 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C ambient temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. DYNAMIC CHARACTERISTICS Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) Settling Time Turn-On Transient Turn-On Time (with 5 mF output capacitance) Start-Up Inhibit Time Output Voltage Overshoot ISOLATION CHARACTERISTICS Typ. Max. 350 100 15 200 0 25 Units Notes & Conditions mV µs 50% to 75% to 50% Iout max To within 1% Vout nom ms ms % Half load, Vout=90% nom. -40 °C to +125 °C; Figure E 5 mF load capacitance Isolation Voltage (dielectric strength) 2000 V See Absolute Maximum Ratings Isolation Resistance 30 MΩ Isolation Capacitance (input to output) 470 pF See Note 3 Semiconductor Junction Temperature 125 °C Package rated to 150 °C Board Temperature 125 °C UL rated max operating temp 130 °C Transformer Core Temperature 125 °C Maximum Baseplate Temperature, Tb 100 °C FEATURE CHARACTERISTICS Switching Frequency 175 200 225 kHz ON/OFF Control (Option P) Off-State Voltage -1 0.8 V On-State Voltage 2.4 18 V ON/OFF Control (Option N) On-State Voltage -1 0.8 V Off-State Voltage 2.4 18 V ON/OFF Control (Either Option) Application notes Figures A & B Pull-Up Voltage 5 V Pull-Up Resistance 124 kΩ Over-Temperature Shutdown OTP Trip Point 135 °C Average PCB Temperature Over-Temperature Shutdown Restart Hysteresis 10 °C RELIABILITY CHARACTERISTICS Calculated MTBF (Telcordia) TR-NWT-000332 4.8 106 Hrs. 80% load, 200LFM, 40 °C Ta Calculated MTBF (MIL-217) MIL-HDBK-217F 3.3 106 Hrs. 80% load, 200LFM, 40 °C Ta Field Demonstrated MTBF 106 Hrs. See our website for details Note 1: UL’s product certification tests were carried out using 20 A fast blow fuse. Fuse interruption characteristics have to be taken into account while Note 2: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: [email protected]) Note 3: Isolation capacitance can be added external to the module. Product # BQ57120QEx50 Phone 1-888-567-9596 www.synqor.com Doc.# 005-0006201 Rev. C 07/21/15 Page 5 Input: 40-65 V Output: 9.3-16.25 V Current: 50A Package: Quarter-brick Technical Specification Compliance & Testing Parameter Notes & Conditions STANDARDS COMPLIANCE UL 60950-1/R2011-12 Basic insulation EN60950-1/A2:2013 CAN/CSA-C22.2 No. 60950-1/A1:2011 Note: An external input fuse must always be used to meet these safety requirements. Contact SynQor for official safety certificates on new releases or download from the SynQor website. Parameter QUALIFICATION TESTING Life Test Vibration Mechanical Shock Temperature Cycling Power/Thermal Cycling Design Marginality Humidity Solderability Product # BQ57120QEx50 # Units 32 5 5 10 5 5 5 15 pins Phone 1-888-567-9596 Test Conditions 95% rated Vin and load, units at derating point, 1000 hours 10-55 Hz sweep, 0.060" total excursion, 1 min./sweep, 120 sweeps for 3 axis 100g minimum, 2 drops in x, y and z axis -40 °C to 100 °C, unit temp. ramp 15 °C/min., 500 cycles Toperating = min to max, Vin = min to max, full load, 100 cycles Tmin-10 °C to Tmax+10 °C, 5 °C steps, Vin = min to max, 0-105% load 85 °C, 95% RH, 1000 hours, continuous Vin applied except 5 min/day MIL-STD-883, method 2003 www.synqor.com Doc.# 005-0006201 Rev. C 07/21/15 Page 6 Input: 40-65 V Output: 9.3-16.25 V Current: 50A Package: Quarter-brick Technical Figures 100 98.0 95 97.5 90 97.0 Efficiency (%) Efficiency (%) 85 80 75 70 96.5 96.0 40 Vin 25º C 52.5 Vin 65 95.5 65 Vin 55º C 60 0 10 20 30 Load Current (A) 40 40º C 95.0 50 Figure 1: Efficiency at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. 100 200 Air Flow (LFM) 300 400 Figure 2: Efficiency at nominal output voltage and 60% rated power vs. airflow rate for ambient air temperatures of 25 °C, 40 °C, and 55 °C (nominal input voltage). 35 14 25 Power Dissipation (W) Power Dissipation (W) 30 20 15 10 40 Vin 13 12 11 40º C 65 Vin 55º C 0 0 10 20 30 Load Current (A) 40 10 100 50 Figure 3: Power dissipation at nominal output voltage vs. load current for minimum, nominal, and maximum input voltage at 25 °C. 200 Air Flow (LFM) 300 400 Figure 4: Power dissipation at nominal output voltage and 60% rated power vs. airflow rate for ambient air temperatures of 25 °C, 40 °C, and 55 °C (nominal input voltage). 700 60 600 50 500 Pout (W) 40 Iout (A) 25º C 52.5 Vin 5 30 20 400 300 200 400 LFM (2.0 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 10 300 LFM (1.5 m/s) 100 200 LFM (1.0 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0 0 25 40 50 60 70 25 85 Ambient Air Temperature (ºC) Phone 1-888-567-9596 Semiconductor junction is 50 60temperature 70 within 1°C of surface temperature 85 Ambient Air Temperature (ºC) Figure 5: Maximum output current derating curve vs. ambient air temperature (with both baseplate and heat sink) at different airflow rates with air flowing from output to input (nominal input voltage). Product # BQ57120QEx50 40 Figure 6: Maximum output power derating curve vs. ambient air temperature (with both baseplate and heat sink) at different airflow rates with air flowing from output to input (nominal input voltage). www.synqor.com Doc.# 005-0006201 Rev. C 07/21/15 Page 7 Input: 40-65 V Output: 9.3-16.25 V Current: 50A Package: Quarter-brick Technical Figures 700 60 600 50 500 Pout (W) Iout (A) 40 30 20 400 300 200 400 LFM (2.0 m/s) 400 LFM (2.0 m/s) 300 LFM (1.5 m/s) 10 300 LFM (1.5 m/s) 100 200 LFM (1.0 m/s) 200 LFM (1.0 m/s) 100 LFM (0.5 m/s) 100 LFM (0.5 m/s) 0 0 25 40 50 60 70 85 25 Ambient Air Temperature (ºC) 40 50 60 70 85 Ambient Air Temperature (ºC) Figure 7: Maximum output current derating curve vs. ambient air temperature (with baseplate only) at different airflow rates with air flowing from output to input (nominal input voltage). Figure 8: Maximum output power derating curve vs. ambient air temperature (with baseplate only) at different airflow rates with air flowing from output to input (nominal input voltage). Figure 9: Turn-on transient at half load (resistive load) (5 ms/div). Load cap: 5 mF ceramic output capacitance. Input voltage pre-applied. Ch 1: Vout (5 V/div). Ch 2: ON/OFF input (2 V/div). Figure 10: Turn-on transient at zero load (5 ms/div). Load cap: 5 mF ceramic output capacitance. Ch 1: Vout (5 V/div), Ch 2: ON/OFF input (2 V/div). Figure 11: Output voltage response to step-change in load current (50%-75%50% of Iout(max); dI/dt = 0.1 A/µs). Load cap: 15 µF, 30 mΩ ESR tantalum cap and 1 µF ceramic cap. Ch 1: Vout (500 mV/div), Ch 2: Iout (20 A/div). tantalum cap and 1 µF ceramic cap. Ch 1: Vout (500 mV/div), Ch 2: Iout (20 A/div). Figure 12: Output voltage response to step-change in load current (50%-75%50% of Iout(max): dI/dt = 1 A/µs). Load cap: 15 µF, 30 mΩ ESR tantalum cap and 1 µF ceramic cap. Ch 1: Vout (500 mV/div), Ch 2: Iout (20 A/div). Product # BQ57120QEx50 Phone 1-888-567-9596 www.synqor.com Doc.# 005-0006201 Rev. C 07/21/15 Page 8 Input: 40-65 V Output: 9.3-16.25 V Current: 50A Package: Quarter-brick Technical Figures Input Reflected Ripple Current source impedance iS Input Terminal Ripple Current iC Output Voltage Ripple DC-DC Converter VOUT VSOURCE electrolytic capacitor ceramic electrolytic capacitor capacitor Figure 13: Test set-up diagram showing measurement points for Input Terminal Ripple Current (Figure 14), Input Reflected Ripple Current (Figure 15) and Output Voltage Ripple (Figure 16). Figure 14: Input Terminal Ripple Current, ic, at full rated output current and nominal input voltage with 10 µH source impedance and 47 µF electrolytic capacitor (500 mA/div). See Figure 13. Figure 15: Input reflected ripple current, is, through a 10 µH source inductor, using a 47 µF electrolytic input capacitor (50 mA/div). See Figure 13. Figure 16: Output voltage ripple at nominal input voltage and rated load current (100 mV/div). Load capacitance: 1 µF ceramic capacitor and 15 µF tantalum capacitor. Bandwidth: 20 MHz. See Figure 13. 18 Output Voltage (V) 15 12 9 6 40 Vin 3 52.5 Vin 65 Vin 0 0 10 20 30 40 50 Load Current (A) 60 70 80 90 Figure 17: Output voltage vs. load current for different input voltages showing typcial current limit curves. Product # BQ57120QEx50 Phone 1-888-567-9596 Figure 18: Load current (50 A/div) as a function of time when the converter attempts to turn on into a 1 mΩ short circuit. Top trace (500 µs/div) is an expansion of the on-time portion of the bottom trace. www.synqor.com Doc.# 005-0006201 Rev. C 07/21/15 Page 9 Input: 40-65 V Output: 9.3-16.25 V Current: 50A Package: Quarter-brick Applications Section BASIC OPERATION AND FEATURES CONTROL FEATURES With voltages dropping and currents rising, the economics of an Intermediate Bus Architecture (IBA) are becoming more attractive, especially in systems requiring multiple low voltages. IBA systems separate the role of isolation and voltage scaling from regulation and sensing. The BusQor series bus converter provides isolation and a coarse voltage step down in one compact module, leaving regulation to simpler, less expensive non-isolated converters. REMOTE ON/OFF (Pin 2): The ON/OFF input, Pin 2, permits the user to control when the converter is on or off. This input is referenced to the return terminal of the input bus, Vin(-). There are two versions of the converter that differ by the sense of the logic used for the ON/OFF input. In Figure A below, the BusQor module provides the isolation stage of the IBA system. The isolated bus then distributes power to the non-isolated buck regulators to generate the required voltage levels at the point of load. In this case, the bucks are represented with SynQor’s NiQor series of non-isolated dc/dc converters. In many applications requiring multiple low voltage outputs, significant savings can be achieved in board space and overall system costs. In the positive logic version, the ON/OFF input is active high (meaning that a high turns the converter on). In the negative logic version, the ON/OFF signal is active low (meaning that a low turns the converter on). Figure B is a detailed look of the internal ON/OFF circuitry. When designing an IBA system with bus converters, the designer can select from a variety of bus voltages. While there is no universally ideal bus voltage, most designs employ one of the following: 12 V, 9 V, 7.5 V, 5 V, or 3.3 V. Higher bus voltages can lead to lower efficiency for the buck regulators but are more efficient for the bus converter and provide lower board level distribution current. Lower bus voltages offer the opposite trade offs. SynQor’s 12 Vout BusQor module acts as a true dc transformer. The output voltage is proportional to the input voltage, with a specified “turns ratio” or voltage ratio, plus minor drop from the internal resistive losses in the module. When used in IBA systems, the output variation of the BusQor must be in accordance with the input voltage range of the non-isolated converters being employed. Vin(+) On/Off 5V 124K 5V 49.9K TTL 100k The BusQor architecture is very scalable, meaning multiple bus converters can be connected directly in parallel to allow current sharing for higher power applications. Vin(-) Figure B: Internal ON/OFF pin circuitry 3.3V Front End 52.5Vdc 40-65V BusQor Converter 13.1Vdc 2.5V 1.8V 1.5V 0.9V Typical User Board Converters Loads Figure A: Example of Intermediate Bus Architecture using BusQor bus converter and NiQor non-isolated converters Product # BQ57120QEx50 Phone 1-888-567-9596 www.synqor.com Doc.# 005-0006201 Rev. C 07/21/15 Page 10 Input: 40-65 V Output: 9.3-16.25 V Current: 50A Package: Quarter-brick Applications Section PROTECTION FEATURES Input Under-Voltage Lockout:The converter is designed to turn off when the input voltage is too low, helping avoid an input system instability problem, described in more detail in the application note titled “Input System Instability”. The lockout circuitry is a comparator with DC hysteresis. When the input voltage is rising, it must exceed the typical TurnOn Voltage Threshold value (listed on the specification page) before the converter will turn on. Once the converter is on, the input voltage must fall below the typical Turn-Off Voltage Threshold value before the converter will turn off. Also see Figure E. Output Current Limit: The output of the BusQor module is electronically protected against output overloads. When an overload current greater than the “DC Current-Limit Inception” specification is drawn from the output, the output shuts down to zero volt in a period of 20 ms typical (see Figure D). The shutdown period lasts for a typical period of 200 ms (Figure D) after which the BusQor tries to power up again. If the overload persists, the output voltage will go through repeated cycles of shutdown and restart with a duty cycle of 10% (On) and 90% (Off) respectively. The BusQor module returns (auto resetting) to normal operation once the overload is removed. The BusQor is designed to survive in this mode indefinitely without damage and without human intervention. Output Current 65A 50A Output Voltage Output Current 95A peak Output Voltage <13.1V 0V Time 220ms 20ms Figure D: Output Short Circuit and Auto-Resetting protection diagram (not to scale) Output Short Circuit Protection: When the output of the BusQor module is shorted, a peak current of typically 95 A will flow into the short circuit for a period of about 20 ms. The output of the BusQor will shutdown to zero for ~ 200 mS (Figure D). At the end of the shutdown period the BusQor module tries to power up again. If the short circuit persists, the output voltage will go through repeated cycles of shutdown and restart with a duty cycle of 10% (On) and 90% (Off) respectively. The BusQor module returns (auto resetting) to normal operation once the short circuit is removed. The BusQor is designed to survive in this mode indefinitely without damage and without human intervention. In the Auto resetting mode, also referred to as “Hiccup” mode, the power drawn from the 52.5 V input is about 5 Watts, most of which is dissipated into the external fault. It is important that copper traces and pads from the output circuit be designed to withstand the short term peaks, although the average current into the fault may be as low as 5 A typical. See Figure 18 for appropriate waveform. 13.1V 0V 1ms Time Figure C: Output Overload protection diagram (not to scale) Product # BQ57120QEx50 Phone 1-888-567-9596 Over-Temperature Shutdown: A temperature sensor on the converter senses the average temperature of the module. The thermal shutdown circuit is designed to turn the converter off when the temperature at the sensed location reaches the Over-Temperature Shutdown value. It will allow the converter to turn on again when the temperature of the sensed location falls by the amount of the Over-Temperature Shutdown Restart Hysteresis value. www.synqor.com Doc.# 005-0006201 Rev. C 07/21/15 Page 11 Input: 40-65 V Output: 9.3-16.25 V Current: 50A Package: Quarter-brick Applications Section APPLICATION CONSIDERATIONS 0.01” Start-Up Inhibit Period: Figure E details the Start-Up Inhibit Period for the BusQor module. At time t0, when Vin is applied with On/Off pin asserted (enabled), the BusQor output begins to build up. Before time t1, when the input voltage is below the UVL threshold, the unit is disabled by the Input Under-Voltage Lockout feature. When the input voltage rises above the UVL threshold, the Input Under-Voltage Lockout is released, and a typical Startup Inhibit Period of 12 ms is initiated. The output builds up to 90% of the nominal value of 13.1 V in a period of 15 ms typical (50 % load). 0.023” At time t2, when the On/Off pin is de-asserted (disabled), the BusQor output instantly drops to 0V. Fall time from 13.1 V to 0 V is dependent on output capacitance and any parasitic trace inductance in the output load circuit. At time t3, when the On/Off pin is re-asserted (enabled), the BusQor module output begins to build up after the inhibit period of 200 ms typical has elapsed. Refer to the Control Features section of the data sheet for details on enabling and disabling methods for N and P logic type modules. Bridging Capacitor 0.01” 1.50” Primary Secondary Figure F: Keep Out Areas for BusQor module All layers including top and bottom, are subject to the keep out areas shown around Primary pins of BusQor module. Actual keep outs along the surface (Creepage) may vary depending on the PCB material CTI. Users are advised to consult UL standards for details. Vin UVLO Bridging Components: Bridging components like EMI filter capacitors required to be placed as close as possible to the BusQor module for optimum performance must observe the clearance/creepage requirements of 0.04”(40 mils) between pads to maintain compliance to UL standards for the overall power system. On/Off (N logic) OFF ON t0 t1 t2 t3 Vout t Vin Start-up Inhibit Fault Inhibit Time Output Load Current Calculation: The BusQor series allows the converter output load to be measured without adding a current loop or external shunt resistor to the designer’s PCB board under test. On the top side of the BusQor converter is a current sense resistor as shown in Figure G. The output load current is proportional to the voltage drop across this sense resistor. This calculation is detailed below. A current sense resistor referenced to the primary input is used in the equation below to calculate the output load current. Start-Up Iload = (VRsense(load) - VRsense(no load) ) x 2000 Figure E: Power Up/Down Diagram (not to scale) showing Start-Up Inhibit Period Component Keep Out Area: Keep out areas for components not referenced to the Primary circuit are shown in shaded areas in Figure F. The keep out areas shown are consistent with UL’s requirements for Basic Insulation of 0.04” (40 mils) for Pollution degree 2. User should consult UL standards for other insulation classes and operating environments. For applications that require mounting parts BELOW the BusQor module, one should be aware of potential high levels of electromagnetic interference, in addition to safety keep out. Users are advised to consult SynQor Applications engineering in such applications. Copper Keep Out Area: Keep out areas shown in Figure F are to be observed for Top layer copper traces and vias. Internal layers buried one or more layers may be exempt, depending on the PCB material grade and thickness. Users are advised to consult UL standards for details. Product # BQ57120QEx50 Note: Referenced keep out widths are adequate to withstand UL’s Basic Insulation Dielectric strength tests for approved PCB materials. Applications requiring Double or Reinforced insulation must double the keep out widths shown in Figure F. Keep out areas shown have standard margins above UL’s minimum requirements. Phone 1-888-567-9596 where: Iload = output load current VRsense(no load) = voltage across the sense resistor with converter at zero load The number 2000 is a “Load Current Scale Factor” for this product, valid only for Vin = 52.5 V. Hence, measurement should be made at this input voltage. The voltage drop across the sense resistor is about 25 mV at full load of 50 A. Therefore, proper measuring techniques must be used to ensure accuracy. A calibrated DMM set to 300 mV is acceptable. Since this measurement is done on the Primary area of the converter, a slight nonlinearity may be observed over the load current range. Measurements should be made at 52.5 V input voltage. Using the Scale Factor referenced above, the error may be on the order of 4%. For more detailed information consult the application note on SynQor’s website titled “Output Load Current Calculations”. www.synqor.com Doc.# 005-0006201 Rev. C 07/21/15 Page 12 Input: 40-65 V Output: 9.3-16.25 V Current: 50A Package: Quarter-brick Applications Section 20.0% 15.0% Deviation from 50/50 Sharing (%) Current Sharing: BusQor modules are designed to operate in parallel without the use of any external current share circuitry. A typical circuit for paralleling two BusQor modules is shown in Figure H. An output capacitor is recommended across each module and located close to the converter for optimum filtering and noise control performance. Dedicated input inductors are recommended but are considered optional. Input capacitors must be located close to the converter module. PCB layout in the input circuit should be such that high frequency ripple currents of each module is restricted to a loop formed by the input capacitors and the input terminals of the BusQor module. See Figure J for details on PCB layout. Contact SynQor application engineering for further assistance on PCB trace design. 10.0% 5.0% 0.0% -5.0% -10.0% Module 1 -15.0% Module 2 -20.0% 10 20 30 40 50 60 70 80 90 100 Total Load Current (A) Figure I: Current share performance of 2 paralleled modules The current share performance of two paralleled modules is illustrated in the graph in Figure I. In this graph the percent deviation from ideal sharing (50%) is plotted for each module versus the total output load current at 48 Vin. Figure G: Location of Sense Resistor + 1 Vin 2 3 + BusQor module (N logic option) 5 — 1 2 3 BusQor module (N logic option) BusQor module CM EMI filter 4 — (Not shown in Figure H) 5 Bulk Cap BusQor module Input LC filters 4 Figure H: BusQor Output Paralleling for increased current output Product # BQ57120QEx50 48 Vin 13.1 Vout 100 A Phone 1-888-567-9596 Figure J: Recommended PCB layout for input circuit www.synqor.com Doc.# 005-0006201 Rev. C 07/21/15 Page 13 Input: 40-65 V Output: 9.3-16.25 V Current: 50A Package: Quarter-brick Ordering Information Part Numbering System Ordering Information The part numbering system for SynQor’s dc-dc converters follows the format shown in the example below. The tables below show the valid model numbers and ordering options for converters in this product family. When ordering SynQor converters, please ensure that you use the complete 15 character part number consisting of the 12 character base part number and the additional characters for options. Add “-G” to the model number for 6/6 RoHS compliance. BQ 5 7 1 2 0 Q E B 5 0 N R S - G 6/6 RoHS Options (see Ordering Information) Model Number Input Voltage BQ57120QEw50xyz-G 40-65 V Output Max Output Voltage Current 9.3-16.25 V 50 A Output Current Thermal Design Performance Level Package Size The following options must be included in place of the w x y z spaces in the model numbers listed above. Output Voltage Input Voltage Product Family Thermal Design A - Open Frame B - Baseplated The first 12 characters comprise the base part number and the last 3 characters indicate available options. The “-G” suffix indicates 6/6 RoHS compliance. Options Description: w x y z Enable Logic Pin Style N - Negative P - Positive K - 0.110" N - 0.145" R - 0.180" Y - 0.250" Feature Set S - Standard Application Notes A variety of application notes and technical white papers can be downloaded in pdf format from our website. RoHS Compliance: The EU led RoHS (Restriction of Hazardous Substances) Directive bans the use of Lead, Cadmium, Hexavalent Chromium, Mercury, Polybrominated Biphenyls (PBB), and Polybrominated Diphenyl Ether (PBDE) in Electrical and Electronic Equipment. This SynQor product is 6/6 RoHS compliant. For more information please refer to SynQor’s RoHS addendum available at our RoHS Compliance / Lead Free Initiative web page or e-mail us at [email protected]. Not all combinations make valid part numbers, please contact SynQor for availability. Contact SynQor for further information and to order: PATENTS Phone: Toll Free: Fax: E-mail: Web: Address: Product # BQ57120QEx50 978-849-0600 888-567-9596 978-849-0602 [email protected] www.synqor.com 155 Swanson Road Boxborough, MA 01719 USA Phone 1-888-567-9596 SynQor holds numerous U.S. patents, one or more of which apply to most of its power converter products. Any that apply to the product(s) listed in this document are identified by markings on the product(s) or on internal components of the product(s) in accordance with U.S. patent laws. SynQor’s patents include the following: 5,999,417 6,222,742 6,545,890 6,594,159 6,731,520 6,894,468 6,896,526 6,927,987 7,050,309 7,072,190 7,085,146 7,119,524 7,269,034 7,272,021 7,272,023 7,558,083 7,564,702 7,765,687 7,787,261 8,023,290 8,149,597 8,493,751 8,644,027 WARRANTY SynQor offers a three (3) year limited warranty. Complete warranty information is listed on our website or is available upon request from SynQor. www.synqor.com Doc.# 005-0006201 Rev. C 07/21/15 Page 14