For more information, please visit the product page. date 08/27/2014 page 1 of 7 SERIES: V78-1000 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR FEATURES • • • • • • • • 1 A current output extremely high efficiency up to 97% no heat sink required pin compatible to LM78XX linear regulators available in straight and right angle SIP packages low ripple and noise short circuit protection, thermal shutdown wide temperature (-40~85°C) RoHS MODEL input voltage output voltage1 output current ripple and noise2 efficiency typ (Vdc) range (Vdc) (Vdc) max (mA) max (mVp-p) Vin min (%) Vin max (%) V7803-1000 24 4.75~28 3.3 1,000 35 90 83 V7805-1000 24 6.5~32 5 1,000 35 93 88 V7806-1000 24 9~32 6.5 1,000 35 94 90 V7809-1000 24 12~32 9 1,000 35 95 92 V7812-1000 24 16~32 12 1,000 35 96 94 V7815-1000 24 20~32 15 1,000 35 97 94 Notes: 1. Not recommended for use in a negative output mode. 2. Ripple and noise are measured at 20 MHz BW, see Test Configuration section. PART NUMBER KEY V78 XX - 1000 X Base Number Output Voltage Output Current cui.com "blank" = straight pins R = 90° pins For more information, please visit the product page. CUI Inc │ SERIES: V78-1000 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR date 08/27/2014 │ page 2 of 7 INPUT parameter conditions/description min typ max units operating input voltage 3.3 Vdc model 5 Vdc model 6.5 Vdc model 9 Vdc model 12 Vdc model 15 Vdc model 4.75 6.5 9.0 12 16 20 24 24 24 24 24 24 28 32 32 32 32 32 Vdc Vdc Vdc Vdc Vdc Vdc parameter conditions/description min typ max units line regulation Vin = min ~ max, at full load ±0.2 ±0.4 % load regulation measured from 10% load to full load ±0.4 ±0.6 % voltage accuracy 100% load ±2 ±3 % switching frequency 100% load, input voltage range 330 450 OUTPUT 280 temperature coefficient ±0.02 load capacitance kHz %/°C 1,000 μF max units PROTECTIONS parameter conditions/description min short circuit protection continuous, automatic recovery thermal shutdown typ 150 °C SAFETY AND COMPLIANCE parameter conditions/description MTBF as per MIL-HDBK-217F, 25°C RoHS compliant 2011/65/EU min typ max 2,000,000 units hours ENVIRONMENTAL parameter conditions/description min operating temperature see derating curve storage temperature case temperature storage humidity non-condensing lead temperature 1.5 mm from case for 10 seconds cui.com typ max units -40 85 °C -55 125 °C 100 °C 95 % 300 °C For more information, please visit the product page. CUI Inc │ SERIES: V78-1000 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR date 08/27/2014 │ page 3 of 7 DERATING CURVES 1. output power vs. ambient temperature Load (%) 100 80 60 40 20 -40 -20 0 20 40 60 71 85 100 120 Ambient Temperature (°C) MECHANICAL parameter conditions/description dimensions 11.50 x 9.00 x 17.50 (0.689 x 0.354 x 0.453 inch) min case material plastic (UL94-V0) typ max units mm weight 3.7 g MECHANICAL DRAWING units: mm [inches] tolerance: ±0.25 [0.010] pin section tolerance: ±0.10 [0.004] V78XX-1000 V78XX-1000R 11.50[0.453] 17.50 [0.689] 0.50 [0.020] 17.50 [0.689] 1.50 [0.059] 4.10 [0.161] (Bottom View) 1.00 [0.039] 2 3 0.30 [0.012] 0.50 [0.020] 1 2 3 1 2.54 [0.100] 1 2.15 [0.085] (Bottom View) 2.15 [0.085] 4.10[0.161] 2.15 [0.085] 5.08 [0.200] 5.08 [0.200] 5.08 [0.200] 9.00 [0.354] 2 5.08 [0.200] 9.00 [0.354] 0.50 [0.020] 11.50[0.453] 3 2.54 [0.100] 1.00 [0.039] PIN CONNECTIONS PIN FUNCTION 1 +Vin 2 GND 3 +Vo cui.com 1.35 [0.053] For more information, please visit the product page. CUI Inc │ SERIES: V78-1000 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR date 08/27/2014 │ page 4 of 7 EXTERNAL CAPACITOR TABLE Part Number C12 (Ceramic capacitor) C2 (Ceramic capacitor) V7803-1000(R) 10μF/50V 22μF/6.3V V7805-1000(R) 10μF/50V 22μF/16V V7806-1000(R) 10μF/50V 10μF/16V V7809-1000(R) 10μF/50V 10μF/16V V7812-1000(R) 10μF/50V 10μF/25V V7815-1000(R) 10μF/50V 10μF/25V TYPICAL APPLICATION CIRCUIT 1 Vin V78XX-1000(R) 3 +Vout 2 C1 C2 GND Notes: 1. C1 and C2 are required and should be fitted close to the converter pins. 2. If the input voltage is greater than 26 Vdc (3.3 Vdc output model) or greater than 28 Vdc (all other models), it is required to have C1 be ≥ 22 µF electrolytic capacitor to protect the part from voltage spikes. OUTPUT RIPPLE REDUCTION 1 C1 DC/DC 3 Converter 2 L +Vout C2 22 F GND To reduce output ripple, it is recommended to add a LC filter in output port. L: Recommended parameter 10 H ~ 47 H. cui.com Load Vin For more information, please visit the product page. CUI Inc │ SERIES: V78-1000 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR date 08/27/2014 │ page 5 of 7 EFFICIENCY AND RIPPLE CURVES Efficiency Ripple Ripple (mV) Efficiency(%) 40 100 35 90 80 V7803-1000 30 V7805-1000 25 V7812-1000 V7806-1000 12 16 20 24 28 32 V7809-1000 V7815-1000 10 60 8 V7812-1000 V7806-1000 15 V7815-1000 4.75 V7805-1000 20 V7809-1000 70 V7803-1000 5 Vin(V) 4.75 Efficiency VS Vin(Full Load) 8 12 16 20 24 28 32 Vin (V) Ripple VS Vin ( Full Load) Efficiency(%) Ripple(mV) 20 100 95 15 90 V7803-1000 V7803-1000 85 V7805-1000 80 V7812-1000 V7806-1000 75 V7809-1000 10 V7805-1000 5 V7809-1000 V7812-1000 V7806-1000 V7815-1000 V7815-1000 70 0 65 40 80 200 400 600 800 1000 Load(mA) Efficiency VS Load(Vin=Vin_min) 40 Efficiency(%) 80 200 400 600 800 1000 Load(mA) Ripple VS Load(Vin=Vin_min) Ripple(mV) 35 100 30 90 25 80 V7803-1000 70 V7812-1000 V7806-1000 60 V7809-1000 80 15 V7812-1000 V7806-1000 10 V7809-1000 V7815-1000 5 V7815-1000 40 V7805-1000 20 V7805-1000 50 V7803-1000 0 200 400 600 800 1000 Load(mA) Efficiency VS Load(Vin=Vin_max) 40 80 200 400 600 800 Ripple VS Load(Vin=24V) cui.com 1000 Load(mA) For more information, please visit the product page. CUI Inc │ SERIES: V78-1000 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR date 08/27/2014 │ page 6 of 7 TEST CONFIGURATION Efficiency and Output Voltage Ripple Test 25.4mm 25.4mm 12.7mm 2 C1 Copper strip C2 1 F +Vout 10 F Ceramic Tantalum Scope GND Load 3 Load DC/DC Converter 2.54 mm 1 2.54 mm Vin Copper strip Start-up and Load Transient Response Test Vin 1 C1 DC/DC Converter 50.8 mm 3 2 Copper strip Scope C2 GND Copper strip Note: All specifications measured at 25°C, humidity <75%, nominal input voltage, and full load unless otherwise noted. cui.com +Vout For more information, please visit the product page. CUI Inc │ SERIES: V78-1000 │ DESCRIPTION: NON-ISOLATED SWITCHING REGULATOR date 08/27/2014 │ page 7 of 7 REVISION HISTORY rev. description date 1.0 initial release 07/13/2010 1.01 V-Infinity branding removed 09/04/2012 1.02 updated typical application circuits 09/25/2012 1.03 corrected switching frequency values 04/22/2013 not recommended for use as an inverter 08/27/2014 1.04 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.