For more information, please visit the product page. date 08/02/2011 page 1 of 2 SERIES: PD-40VS │ DESCRIPTION: 4 PIN POWER DIN FEATURES • PCB mount • vertical • shielded RoHS SPECIFICATIONS parameter conditions/description min typ rated input voltage max units 20 Vdc rated input current 7.5 A contact resistance 30 mΩ insulation resistance at 500 Vdc at 500 Vdc, after environmental tests voltage withstand at 50/60Hz for 1 minute 100 50 MΩ MΩ 500 Vac MECHANICAL DRAWING units: mm [inch] 8.80 0.346 2.2X0.8 (4PLCS) 1.9X0.7 (2PLCS) 3.80 0.150 1.70 0.067 (4PLCS) 1 8.80 0.346 3 2.40 0.094 2 4 1.60 0.063 2.30 0.091 (2PLCS) MATERIAL PLATING inner shield 0.4T bronze nickel plated metal shell 0.3T bronze nickel plated contact terminal 0.3T phosphor bronze silver plated cover PBT black color housing PBT black color plastic PA6T 5.00 0.197 10.60 0.417 PCB LAYOUT TOP VEIW 10.60 0.417 4.00 0.157 11.50 0.453 0.50 0.020 3.50 0.138 3.80 0.150 1.50 0.059 (4PLCS) 2 16.20 0.638 12.80 0.504 8.80 0.346 1 2.40 0.094 4 3 1.60 0.063 15.60 0.614 4.00 0.157 5.00 0.197 8.80 0.346 cui.com For more information, please visit the product page. CUI Inc │ SERIES: PD-40VS │ DESCRIPTION: 4 PIN POWER DIN date 08/02/2011 page 2 of 2 REVISION HISTORY rev. 1.0 description date initial release 8/02/2011 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.