UL Listing File S789

UOJZ.S789 - Control Units, System
Home Quick Guide Contact Us UL.com
UOJZ.S789
Control Units, System
Page Bottom
Control Units, System
See General Information for Control Units, System
HONEYWELL SECURITY
S789
SUITE 100
2 CORPORATE CENTER DR
PO BOX 9040
MELVILLE, NY 11747 USA
Model
Initiating
Device
Type(s)
Control Unit
System Type
Signaling
Type(s)
control unit
9500, 9800, 9850, MX8000
FA1670CT
FA1700CT
Vista-128FBP, Vista-128FBPN, Vista 250FBP
(h)
Vista-128FBPT
Vista-250FBPT, TYCMSM250, TYC250F
Vista-32FB(h)
Vista-32FBPT
UOJZ.S789 - Control Units, System.html[2/8/2016 12:43:08 PM]
CS (RU)
A, M, SS, WF
DAC
L
A, M, SS, WF
March, NC
RS (PPU)
A, M, SS, WF
DAC, OT
P (PPU)
A, M, SS, WF
DAC, OT
CS (PPU)
A, M, SS, WF
DAC, OT
L
A, M, SS, WF
March, NC
RS (PPU)
A, M, SS, WF
DAC, OT
P (PPU)
A, M, SS, WF
DAC, OT
CS (PPU)
A, M, SS, WF
DAC, OT
CS (PPU), L, P (PPU), RS
(PPU)
A, M, SS, WF
DAC, NC, OT
L
A, M, SS, WF
March, NC
RS (PPU)
A, M, SS, WF
DAC, OT
P (PPU)
A, M, SS, WF
DAC, OT
CS (PPU)
A, M, SS, WF
DAC, OT
L
A, M, SS, WF
March, NC
RS (PPU)
A, M, SS, WF
DAC, OT
P (PPU)
A, M, SS, WF
DAC, OT
CS (PPU)
A, M, SS, WF
DAC, OT
CS (PPU), P (PPU), RS (PPU)
A, M, SS, WF
DAC, MX, NC,
OT
L
A, M, SS, WF
March, NC
RS (PPU)
A, M, SS, WF
DAC, OT
UOJZ.S789 - Control Units, System
P (PPU)
A, M, SS, WF
DAC, OT
CS (PPU)
A, M, SS, WF
DAC, OT
CS (RU), P (RU)
-
OT
FA1670C(h)
CS (PPU), L, P (PPU), RS
(PPU)
A, M, SS, WF
DAC, NC, OT
FA1700C(h)
CS (PPU), L, P (PPU), RS
(PPU)
A, M, SS, WF
DAC, NC, OT
CS, L, P, RS
A, M, SS, WF
DAC, NC, OT
Internet Receiver
7810iR-ent (c)
FOCUS 200 PLUS (b)
Control unit enclosures, Model(s) COM-UL
Control unit sub-assemblies, Model(s) 472490 (5800ADT) RF Gateway (g)
CS (RU) - Central Station System (Supervising Station Receiving Unit)
A - Automatic Fire Alarm: thermostats, smoke detectors, etc.
M - Manual Fire Alarm: manually operated boxes
SS - Supervisory: gate valves, water-level switches, temperature switches, carbon monoxide alarm, residential fire alarm control
units, etc.
WF - Waterflow Alarm: waterflow switches
DAC - Digital Alarm Communicator
L - Local System
March - March Time
NC - Noncoded, Steady, Temporal 3 Pattern, etc.
RS (PPU) - Remote Station System (Protected Premises Unit)
OT - Other Transmission Technologies
P (PPU) - Proporiety System (Protected Premises Unit)
CS (PPU) - Central Station System (Protected Premises Unit)
MX - Multiplex
P (RU) - Proporiety System (Supervising Station Receiving Unit)
CS - Central Station System
P - Proprietary System
RS - Remote Station System
(b) - FOCUS 200 PLUS Control Unit, consisting of Model SAFOC200-1, SAFOC200-2, SAFOC200-VE or SAF200PA Sub-Assembly Circuit
Board and Model COM-UL Enclosure. For Remote Station fire alarm service the 472404 or 1451, 72 VA Transformer must be used. For
central Station fire alarm service either the 472404 or 1451, 72 VA transformer may be used. The following accessories are also
suitable for use with the FOCUS 200 PLUS control unit, 148320 Junction Box, 472402A (5140DLM) Backup DACT, 427368 SIM
Gateway, 472490(5800ADT) RF Gateway, 471883 COPID and 472488 SIM (Sensor Interface Module).
(g) - For use with Model FOCUS 200 PLUS control units.
(h) - Requires additional equipment for OT Signaling
Last Updated on 2015-04-27
Questions?
Print this page
Terms of Use
Page Top
© 2016 UL LLC
The appearance of a company's name or product in this database does not in itself assure that products so identified have been
manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and
covered under UL's Follow-Up Service. Always look for the Mark on the product.
UOJZ.S789 - Control Units, System.html[2/8/2016 12:43:08 PM]
UOJZ.S789 - Control Units, System
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The
Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and
in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online
Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material
must include a copyright notice in the following format: "© 2016 UL LLC".
UOJZ.S789 - Control Units, System.html[2/8/2016 12:43:08 PM]