データシート

For more information, please visit the product page.
Date: 6/25/2007
Part No: CEP-1173
Unit: mm
Description: piezo audio transducer
Page No: 1 of 4
Specifications
Resonant frequency
Operating voltage
Current consumption
Sound pressure level
Rated voltage
Tone
Operating temperature
Storage temperature
Dimensions
Weight
Material
Terminal
RoHS
3.3 KHz ± 0.5
3 ~ 28 V dc
7 mA max.
at 12 V dc
82 db min.
at 30 cm / 12 V dc
12 V dc
Continuous
-30 ~ +80° C
-40 ~ +95° C
ø32.0 x H13.5 mm
7.4 g max.
ABS UL-94 1/16” HB (Black)
Wire type
yes
Appearance Drawing
Tolerance: ±0.5
---M
red wire
blue wire ---F
black wire ---G
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
For more information, please visit the product page.
Date: 6/25/2007
Part No: CEP-1173
Unit: mm
Description: piezo audio transducer
Page No: 2 of 4
Measurement Method
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
For more information, please visit the product page.
Date: 6/25/2007
Part No: CEP-1173
Unit: mm
Description: piezo audio transducer
Page No: 3 of 4
Mechanical Characteristics
Item
Solderability
(Connector excepted)
Terminal Mechanical Strength
Vibration
Drop Test
Test Condition
Stripped wires of lead wires are immersed in
rosin for 5 seconds and then immersed in
a solder bath of +270 ±5°C for 3 ±0.5 seconds.
The pull force should be applied to the double
lead wire:
Horizontal 3.0N (0.306kg) for 30 seconds
Vertical 2.0N (0.204kg) for 30 seconds
The buzzer shall be measured after applying
a vibration amplitude of 1.5 mm with 10 to
55 Hz band of vibration frequency to each of
the 3 perpendicular directions for 2 hours.
The part will be dropped from a height of
75 cm onto a 40 mm thick wooden board 3
times in 3 axes (X, Y, Z) for a total of 9 drops.
Evaluation Standard
90% min. of the stripped wires
will be wet with solder.
(Except the edge of the terminal)
Test Condition
After being placed in a chamber at +95°C for
240 hours.
After being placed in a chamber at -40°C for
240 hours.
After being placed in a chamber at +40°C and
90±5% relative humidity for 240 hours.
The part shall be subjected to 5 cycles. One
cycle will consist of:
Evaluation Standard
No damage or cutting off.
The value of oscillation
frequency/current consumption
should be ±10% of the initial
measurements. The SPL should
be within ±10dB compared with
the initial measurement.
Environment Test
Item
High temp. test
Low temp. test
Humidity test
Temp. cycle test
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
The buzzer will be measured after
being placed at +25°C for 4
hours. The value of the
oscillation frequency/current
consumption should be ±10%
compared to the initial
measurements. The SPL should
be within ±10dB compared to the
initial measurements.
20050 SW 112th Ave.
Tualatin, OR 97062
For more information, please visit the product page.
Date: 6/25/2007
Part No: CEP-1173
Unit: mm
Description: piezo audio transducer
Page No: 4 of 4
Reliability Test
Item
Operating (Life Test)
Test Condition
1. Continuous life test:
The part will be subjected to 48 hours of
continuous operation at +65°C with rated
voltage applied.
2. Intermittent life test:
A duty cycle of 1 minute on, 1 minute off, a
minimum of 5,000 times at room temp
(+25 ±2°C) with rated voltage applied.
Evaluation Standard
The buzzer will be measured after
being placed at +25°C for 4
hours. The value of the
oscillation frequency/current
consumption should be ±10%
compared to the initial
measurements. The SPL should
be within ±10dB compared to
the initial measurements.
Test Conditions
Standard Test Condition
Judgement Test Condition
a) Tempurature: +5 ~ +35°C
a) Tempurature: +25 ±2°C
b) Humidity: 45 - 85%
b) Humidity: 60 - 70%
c) Pressure: 860-1060 mbar
c) Pressure: 860-1060 mbar
Packaging