Datasheet

Series CCRS-33S/CRS-33S
COAX SWITCHES
Miniature DC–18 GHz
Failsafe 2P3T Coaxial Switch
PART NUMBER
DESCRIPTION
CCRS-33S
Commercial Failsafe 2P3T, DC-18GHz
CRS-33S
Elite Failsafe 2P3T, DC-18GHz
The CCRS-33S/CRS-33S is a broadband, 2P3T, electromechanical coaxial switch designed to switch a
microwave signal from a common input to either of two outputs. The characteristic
impedance is 50 Ohms. The switches are small with the minimum spacing that is compatible with SMA
connectors, and can also be used as a SPDT switch with external terminations.
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS
ELECTRICAL CHARACTERISTICS
Operating Temperature
Commercial Model, CCRS-33S
Elite Model, CRS-33S
Form Factor
–40°C to 65°C
–55°C to 85°C
2P3T,
break before make
Vibration (MIL-STD-202 Method 214,
Condition D, non-operating)
10 g’s RMS
Frequency Range
CCRS-33S
CRS-33S
DC–18 GHz
DC–18 GHz
Shock (MIL-STD-202 Method 213,
Condition D, non-operating)
500 g’s
Characteristic Impedance
50 Ohms
Standard Actuator Life
Actuator Life w/ Additional Features
5,000,000 cycles
1,000,000 cycles
Connector Type
SMA
Humidity (Moisture Seal)
Available
Weight
2.65 oz. (75.1g) (max.)
Operate Time
10 ms (max.)
Release Time
10 ms (max.)
Actuation Voltage Available
12
Actuation Current, max. @ ambient
420 350 280 200 mA
15
24
28 V
PERFORMANCE CHARACTERISTICS
Frequency
DC–6 GHz
6–12 GHz
12–18 GHz
0.1
0.2
0.3
Insertion Loss, dB,
max.
Isolation, dB, min.
VSWR , max.
85
80
75
1.1:1
1.2:1
1.3:1
PART NUMBERING SYSTEM
CCRS-33
S
1
C
-
T **
Options
Series
Connectors
Actuator Type
Actuator Voltage
Connector
S: SMA Female
Actuator Voltage
1: 28 Vdc Failsafe
2: 15 Vdc Failsafe
3: 12 Vdc Failsafe
4: 24 Vdc Failsafe
Actuator Type
O: Standard Contacts
C: Indicator Contacts
**SEE PARTS LIST ON PAGE 8
Options
T: TTL Drivers with Diodes
D: Transient Suppression
Diodes
M: Moisture Seal
S: 9 Pin D-Sub Connector
For other options, contact factory.
© 2012 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCRS-33S/CRS-33S Page 1
CCRS-33S\CRS-33S\062012\Q2
Series CCRS-33S/CRS-33S
COAX SWITCHES
Miniature DC–18 GHz
Failsafe 2P3T Coaxial Switch
SCHEMATICS AND MECHANICAL OUTLINE
2X SOLDER TERMINALS
SOLDER WIRE MAXIMUM
TEMP 250ºC FOR NO
MORE THAN 5 SEC
H = 1.75 STD & Indicator Model
H = 1.90 All OTHER Models
Indicators
Analog
TTL
1
6
“-S OPTION” 9-PIN D-SUB CONNECTOR (EXAMPLE:
9 PIN D-SUB PINOUT FOR FAILSAFE 2P3T
TRUTH TABLE (with TTL option)
OPTIONS
Pin
No.
1
2
3
4
5
6
7
8
9
Basic
Indicators
+
-
+
-
CCRS-33S/CRS-33S Page 2
A
B
C
TTL
CCRS-33S10-S)
Indicators &
TTL
Common
1
Common
1
Vsw
Vsw
A
B
C
Logic
Input
RF Path
Indicator
(if applicable)
1
0
2&3
4&5
B&C
1
1&2
3&4
A&C
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2012 TELEDYNE COAX SWITCHES
CCRS-33S\CRS-33S\062012\Q2
Series CCRS-33S/CRS-33S
COAX SWITCHES
Miniature DC–18 GHz
Failsafe 2P3T Coaxial Switch
TYPICAL NARROWBAND RF INSERTION LOSS PERFORMANCE CURVES
Insertion Loss ( 6-12 GHz )
0.0
0.0
-0.1
-0.1
-0.2
-0.2
Insertion Loss (dB)
Insertion Loss (dB)
Insertion Loss ( DC-6 GHz )
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
-1.0
0
1
2
3
4
5
6
6
Frequency (GHz)
7
8
9
10
11
12
Frequency (GHz)
Insertion Loss ( 12-18 GHz )
0.0
Insertion Loss (dB)
-0.1
-0.2
-0.3
-0.4
-0.5
-0.6
-0.7
-0.8
-0.9
-1.0
12
13
14
15
16
17
18
Frequency (GHz)
RF NOTES
© 2012 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCRS-33S/CRS-33S Page 3
CCRS-33S\CRS-33S\062012\Q2
Series CCRS-33S/CRS-33S
COAX SWITCHES
Miniature DC–18 GHz
Failsafe 2P3T Coaxial Switch
TYPICAL NARROWBAND RF ISOLATION PERFORMANCE CURVES
Isolation ( 6-12 GHz )
0
-20
-20
-40
-40
Isolation (dB)
Isolation (dB)
Isolation ( DC-6 GHz )
0
-60
-80
-60
-80
-100
-100
-120
-120
-140
-140
0
1
2
3
4
5
6
6
7
Frequency (GHz)
8
9
10
11
12
Frequency (GHz)
Isolation ( 12-18 GHz )
0
-20
Isolation (dB)
-40
-60
-80
-100
-120
-140
12
13
14
15
16
17
18
Frequency (GHz)
RF NOTES
CCRS-33S/CRS-33S Page 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2012 TELEDYNE COAX SWITCHES
CCRS-33S\CRS-33S\062012\Q2
Series CCRS-33S/CRS-33S
COAX SWITCHES
Miniature DC–18 GHz
Failsafe 2P3T Coaxial Switch
TYPICAL NARROWBAND RF VSWR PERFORMANCE CURVES
VSWR ( 6-12 GHz )
2.0
1.9
1.9
1.8
1.8
1.7
1.7
1.6
1.6
VSWR
VSWR
VSWR ( DC-6 GHz )
2.0
1.5
1.4
1.5
1.4
1.3
1.3
1.2
1.2
1.1
1.1
1.0
1.0
0
1
2
3
4
5
6
6
Frequency (GHz)
7
8
9
10
11
12
Frequency (GHz)
VSWR ( 12-18 GHz )
2.0
1.9
1.8
VSWR
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
12
13
14
15
16
17
18
Frequency (GHz)
RF NOTES
© 2012 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCRS-33S/CRS-33S Page 5
CCRS-33S\CRS-33S\062012\Q2
Series CCRS-33S/CRS-33S
COAX SWITCHES
Miniature DC–18 GHz
Failsafe 2P3T Coaxial Switch
TYPICAL POWER PERFORMANCE CURVE
Power Handling vs. Frequency
3000
2000
Power (W)
1000
800
600
400 STAN
DAR
DS
300
MA
200
SW
ITC
HES
100
80
60
40
30
20
10
.1
.2
.3 .4 .6 .8 1
2
4
6 8 10
18
Frequency GHz
Estimates based on the following reference conditions:
• Ambient temperature of 40°C or less
• Sea level operation
• Load VSWR of 1.20:1 maximum
• No high-power (hot) switching
Please contact Teledyne Coax Switches for derating factors when applications do not meet the foregoing reference conditions.
CCRS-33S/CRS-33S Page 6
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2012 TELEDYNE COAX SWITCHES
CCRS-33S\CRS-33S\062012\Q2
Series CCRS-33S/CRS-33S
COAX SWITCHES
Miniature DC–18 GHz
Failsafe 2P3T Coaxial Switch
GLOSSARY
Actuator
An actuator is the electromechanical mechanism that
transfers the RF contacts from one position to another upon
DC command.
Arc Suppression Diode
A diode is connected in parallel with the coil. This diode
limits the “reverse EMF spike” generated when the coil deenergizes to 0.7 volts. The diode cathode is connected to
the positive side of the coil and the anode is connected to
the negative side.
Date Code
All switches are marked with either a unique serial number
or a date code. Date codes are in accordance with MILSTD-1285 Paragraph 5.2.5 and consist of four digits.
The first two digits define the year and the last two digits
define the week of the year (YYWW). Thus, 1032 identifies
switches that passed through final inspection during the
32nd week of 2010.
Failsafe
A failsafe switch reverts to the default or failsafe position
when actuating voltage is removed. This is realized by a
return spring within the drive mechanism. This type of switch
requires the continuous application of operating voltage to
select and hold any position. (Multi-position switches are
normally open with no voltage applied).
Indicator
Indicators tell the system which position the switch is in.
Other names for indicators are telemetry contacts or tellback
circuit. Indicators are usually a set of internally mounted DC
contacts linked to the actuator. They can be wired to digital
input lines, status lights, or interlocks. Unless otherwise
specified, the maximum indicator contact rating is 30 Vdc,
50 mA, or 1.5 Watts into a resistive load.
Performance Parameters vs Frequency
Generally speaking, the RF performance of coaxial switches
is frequency dependent. With increasing frequency, VSWR
and insertion loss increase while isolation decreases. All
data sheets specify these three parameters as “worst case”
at the highest operating frequency. If the switch is to be
used over a narrow frequency band, better performance
can be achieved.
Actuator Current vs Temperature
The resistance of the actuator coil varies as a function of
temperature. There is an inverse relationship between the
operating temperature of the switch and the actuator drive
current. For switches operating at 28 VDC, the approximate
actuator drive current at temperature, T, can be calculated
using the equation:
IT =
IA
[1 + .00385 (T-20)]
Where:
IT = Actuator current at temperature, T
IA = Room temperature actuator current –
see data sheet
T = Temperature of interest in °C
Magnetic Sensitivity
An electro-mechanical switch can be sensitive to ferrous
materials and external magnetic fields. Neighboring ferrous
materials should be permitted no closer than 0.5 inches and
adjacent external magnetic fields should be limited to a flux
density of less than 5 Gauss.
Isolation
Isolation is the measure of the power level at the output
connector of an unconnected RF channel as referenced to
the power at the input connector. It is specified in dB below
the input power level.
Switching Time
Switching time is the total interval beginning with the arrival
of the leading edge of the command pulse at the switch DC
input and ending with the completion of the switch transfer,
including contact bounce. It consists of three parts: (1)
inductive delay in the coil, (2) transfer time of the physical
movement of the contacts, and (3) the bounce time of the
RF contacts.
TTL Switch Driver Option
As a special option, switch drivers can be provided for both
failsafe and latching switches, which are compatible with
industry-standard low-power Schottky TTL circuits.
© 2012 TELEDYNE RELAYS
(800) 284-7007 • www.teledynecoax.com
CCRS-33S/CRS-33S Page 7
CCRS-33S\CRS-33S\062012\Q2
Series CCRS-33S/CRS-33S
Miniature DC–18 GHz
Failsafe 2P3T Coaxial Switch
COAX SWITCHES
FAILSAFE CCRS-33S/CRS-33S PART NUMBER LIST
PART NO.
*
PART NO.
1
CCRS-33SXC
43
CRS-33SXO-MS
2
CCRS-33SXC-D
44
CRS-33SXO-S
3
CCRS-33SXC-DM
45
CRS-33SXO-T
4
CCRS-33SXC-DMS
46
CRS-33SXO-TM
5
CCRS-33SXC-DS
47
CRS-33SXO-TMS
6
CCRS-33SXC-M
48
CRS-33SXO-TS
7
CCRS-33SXC-MS
8
CCRS-33SXC-S
9
CCRS-33SXC-T
10
CCRS-33SXC-TM
11
CCRS-33SXC-TMS
12
CCRS-33SXC-TS
13
CCRS-33SXO
14
CCRS-33SXO-D
15
CCRS-33SXO-DM
16
CCRS-33SXO-DMS
17
CCRS-33SXO-DS
18
CCRS-33SXO-M
19
CCRS-33SXO-MS
20
CCRS-33SXO-S
21
CCRS-33SXO-T
22
CCRS-33SXO-TM
23
CCRS-33SXO-TMS
24
CCRS-33SXO-TS
25
CRS-33SXC
26
CRS-33SXC-D
27
CRS-33SXC-DM
28
CRS-33SXC-DMS
29
CRS-33SXC-DS
30
CRS-33SXC-M
31
CRS-33SXC-MS
32
CRS-33SXC-S
33
CRS-33SXC-T
34
CRS-33SXC-TM
35
CRS-33SXC-TMS
36
CRS-33SXC-TS
37
CRS-33SXO
38
CRS-33SXO-D
39
CRS-33SXO-DM
40
CRS-33SXO-DMS
41
CRS-33SXO-DS
42
CRS-33SXO-M
X = 1 (28Vdc), 2 (15Vdc), 3 (12Vdc) and 4 (24Vdc)
CCRS-33S/CRS-33S Page 8
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2012 TELEDYNE COAX SWITCHES
CCRS-33S\CRS-33S\062012\Q2