データシート

For more information, please visit the product page.
Part No: CCG-1206
Date: 3/19/2007
Description: magnetic buzzer
Page No: 1 of 4
Unit: mm
Specifications
Rated voltage
5 Vo-p
Operating voltage
Mean current
4.0 - 8.0 Vo-p
50 mA max.
Coil resistance
Sound output
40 ± 6 Ω
Min. 85 (Typical 91) dBA
Rated frequency
Operating tempurature
Storage tempurature
Dimensions
Weight
Material
Terminal
RoHS
2,400 Hz
-30 ~ +70° C
-40 ~ +85° C
ø12 x H10 mm
1.6 g
PBT+15% (Black)
Pin type (Au Plating)
yes
Applying rated voltage, 2400 Hz
square wave, ½ duty
Distance at 10cm (A-weight free air).
Applying rated voltage of 2400 Hz, square
wave, ½ duty.
See attached drawing
See attached drawing
Frequency Response Curve
Phone: 800.275.4899
Fax: 503.612.2383
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
For more information, please visit the product page.
Part No: CCG-1206
Date: 3/19/2007
Description: magnetic buzzer
Page No: 2 of 4
Unit: mm
Appearance Drawing
Tolerance: ±0.5
Week
01
02
.
.
Year
05---2005
06---2006
.
.
Measurement Method
Phone: 800.275.4899
Fax: 503.612.2383
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
For more information, please visit the product page.
Part No: CCG-1206
Date: 3/19/2007
Description: magnetic buzzer
Page No: 3 of 4
Unit: mm
Mechanical Characteristics
Item
Solderability
Test Condition
Lead terminals are immersed in a solder bath
of +270 ±5°C for 3 ±1 seconds.
Soldering Heat Resistance
Lead terminals are immersed in solder bath
of +260 ±5°C for 3 ±1 seconds.
The force of 9.8N (1.0kg) should be applied to
each terminal in each axial direction.
The buzzer will be measured after applying
a vibration amplitude of 1.5 mm with 10 to
55 Hz band of vibration frequency to each of
the 3 perpendicular directions for 2 hours
The part should be dropped from a height of
75 cm onto a 40 mm thick wooden board 3
times in 3 axis (X, Y, Z) for a total of 9 drops.
Terminal Mechanical Strength
Vibration
Drop Test
Evaluation Standard
90% min. of lead terminals should
be covered with fresh solder.
(Except the edge of the terminal.)
No in interference in operation.
No damage or cutting off.
After the test, the part should
meet specifications without any
damage to the appearance and
the SPL should be within
±10 dBA of the initial
measurement.
Environment Test
Item
High temp. test
Low temp. test
Thermal shock
Temp./Humidity cycle
Phone: 800.275.4899
Test Condition
The part will be subjected to +85°C for
96 hours.
The part will be subjected to -40°C for
96 hours
The part will be subjected to 10 cycles. One
cycle will consist of:
The part shall be subjected to 10 cycles. One
cycle should last 24 hours and will consist of:
Fax: 503.612.2383
www.cui.com
Evaluation Standard
After the test, the part should
meet specifications without any
damage to the appearance or
performance except SPL. After 4
hours at 25°C, the SPL should be
within ±10 dBA of the initial
measurement.
20050 SW 112th Ave.
Tualatin, OR 97062
For more information, please visit the product page.
Part No: CCG-1206
Date: 3/19/2007
Description: magnetic buzzer
Page No: 4 of 4
Unit: mm
Reliability Tests
Item
Operating (Life Test)
Test Condition
1. Continuous life test:
The part will be subjected to 72 hours at 55°C
with 5 V, 2400 Hz applied.
Evaluation Standard
2. Intermittent life test:
A duty cycle of 1 minute on, 1 minute off, a
minimum of 10,000 times at room temp.
(+25 ±10°C) with 5 V, 2400 Hz applied.
After the test, the part should
meet specifications without any
damage to the appearance or
performance except SPL. After 4
hours at 25°C, the SPL should be
80 dBA or more.
Test Conditions
Standard Test Condition
Judgement Test Condition
a) Tempurature: +5 ~ +35°C
a) Tempurature: +25±2°C
b) Humidity: 45 - 85%
b) Humidity: 60 - 70%
c) Pressure: 860 - 1060 mbar
c) Pressure: 860 - 1060 mbar
Packaging
Phone: 800.275.4899
Fax: 503.612.2383
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062