Datasheet

Scheda prodotto
Elettromagneti Series NT
Elettromagneti Lineari
This Solenoid Series has been specifically designed for maximum AC performance, with both the frame and
plunger of laminated steel construction, made of special magnetic steel featuring high magnetic permeability
and low magnetic losses. Designed to be used in any position, they are able to transform an electric power
into an axial pull action.
Coils have Class F insulation. Performance, as shown in the force diagrams, is normally referred to a
temperature rise of 80°C in open air, with 35°C ambient temperature and coils fed at 105% of rated supply
voltage (as per VDE 0580).
ITALIANA RELE' Srl. - Via dei Bravi 40 I-20032 CORMANO - Italy
Tel(+39) 02 6140851 - Fax(+39) 02 6140339 - Email: [email protected] - www.rele.it
Page 1/8
Scheda prodotto
Elettromagneti Series NT
Selection Guide
To select the best solenoid suiting your application you must always know the force required, as well as stroke, maximum ON time, minimum OFF
time, maximum ambient
temperature, and supply voltage.
Since the mechanical energy produced by solenoids is constant, any amount of this force eventually unutilised by relevant application will be
expended under form of impact force. As a consequence, every application should correctly use the smallest available solenoid performing the
required work without exceeding the maximum admitted working temperature.
An exact determantion of duty cycle is equally essential to select the right solenoid. Whenever a continuously or an intermittently rated coil is required,
please refer to the table indluded in the section dedicated to relative duty factor.
Every AC solenoid, due to its high power rating (VA), would rapidly overheat
and fail to operate, whenever its plunger is prevented from seating properly.
To avoid this, an adequate spring should be mounted between plunger and
application. When mounting a solenoid please bear always in mind the following:
1. Any load must be absolutely applied along the main plunger axis (to avoid wear due
to excessive friction, and amplification of noise due to vibration of AC power
supply).
2. All mechanical stroke-limiting devices, if any, should be made of non magnetic
material.
3. Expected life of solenoid will be dramatically increased as much as the impact force
will be absorbed by any fixing device.
When a continuously rated solenoid is required but space is at premium, a resistor and/or an impedance could be used to a feed a smaller
intermittently rated solenoid, to limit the current after the plunger is fully seated inside.
Types NT1, NT2 and NT5 are supplied with fixing brackets included, while NT3 and NT4 are not including any bracket, even if they can be added as
an optional kit.
If you are in doubt of selecting the right solenoid for your application, please don't hesitate contacting us to help you with the right choice, supplying us
with all required data as indicated above. Also, if you can't find the solenoid you require in our range, please get in touch with us, as we do have both
the experience and the
technical knowledge to provide any solution to your problems in this field.
ITALIANA RELE' Srl. - Via dei Bravi 40 I-20032 CORMANO - Italy
Tel(+39) 02 6140851 - Fax(+39) 02 6140339 - Email: [email protected] - www.rele.it
Page 2/8
Scheda prodotto
Elettromagneti Series NT
Duty Factor
Duty Service (ED%)
Operations per hour
Total cycle
ED 40
ED 25
ED 15
ED 5
(seconds)
ON time OFF time ON time OFF time ON time OFF time ON time OFF time
12
300
120
180
75
225
45
255
15
285
120
30
12
18
7,5
2,25
4,5
25,5
1,5
28,5
300
12
4,8
7,2
3
9
1,8
10,2
0,6
11,4
600
6
2,4
3,6
1,5
4,5
0,9
5,1
0,3
5,7
1200
3
1,2
1,8
0,75
2,25
0,45
2,55
0,15
2,85
1800
2
0,8
1,2
0,5
1,5
0,3
1,7
0,1
1,9
3000
1,2
0,48
0,72
0,3
0,9
0,18
1,02
0,06
1,14
Whenever the maximum cycle time is exceeding 300 seconds, a continuously rated solenoid (ED=100) should be used.
Otherwise, the relative duty factor is resulting as follows:
ED% = [Ti / (Ti + Tr)] x 100
(where: Ti = ON time and Tr = OFF time)
The table above is showing ON and OFF times corresponding to intermittently rated coils (ED lower than 100) for standard ED values.
Environmental compatibility
(European Directive 2011/65/EU)
ITALIANA RELE' Srl. - Via dei Bravi 40 I-20032 CORMANO - Italy
Tel(+39) 02 6140851 - Fax(+39) 02 6140339 - Email: [email protected] - www.rele.it
Page 3/8
Scheda prodotto
Elettromagneti Series NT
Type NT1
Axial Force Vs. Stroke and Duty Service
Duty Service
Stroke
ED
2 mm
5 mm
10 mm
15 mm
100 %
11.0 N
7.0 N
5.5 N
4.5 N
40 %
18.1 N
12.2 N
9.3 N
7.5 N
25 %
20.1 N
14.2 N
10.3 N
8.3 N
15 %
23.5 N
16.7 N
11.8 N
9.3 N
5%
28.0 N
19.1 N
13.7 N
10.3 N
Current values shown in diagrams are at rated voltage. Forces shown are referring to solenoids fed at 90% of rated voltage, with 'hot' coil and 20°C
ambient temperature.
Coil supply voltages: 12-24-110-230 VAC (50 or 60 Hz)
Insulating resistance: > 100 Mohm at 500 V DC
Dielectric strenght: 2 KV
Coil terminals: Faston 0.25 (6.35x0.8 mm) or 150 mm long leads
Total weight: 190 grams
Plunger weight: 50 grams
ITALIANA RELE' Srl. - Via dei Bravi 40 I-20032 CORMANO - Italy
Tel(+39) 02 6140851 - Fax(+39) 02 6140339 - Email: [email protected] - www.rele.it
Page 4/8
Scheda prodotto
Elettromagneti Series NT
Type NT2
Axial Force Vs. Stroke and Duty Service
Duty Service
Stroke
ED
2 mm
5 mm 10 mm
15 mm
100%
17 N
14 N
10 N
7.5 N
40%
27 N
22 N
16 N
11 N
25%
30 N
25 N
18 N
12.5 N
15%
36 N
29 N
20 N
14 N
5%
43 N
34 N
24 N
17 N
Current values shown in diagrams are at rated voltage. Forces shown are referring to solenoids fed at 90% of rated voltage, with 'hot' coil and 20°C
ambient temperature.
Coil supply voltages: 12-24-110-230 VAC (50 or 60 Hz)
Insulating resistance: > 100 Mohm at 500 V DC
Dielectric strenght: 2 KV
Coil terminals: Faston 0.25 (6.35x0.8 mm) or 150 mm long leads
Total weight: 240 grams
Plunger weight: 75 grams
ITALIANA RELE' Srl. - Via dei Bravi 40 I-20032 CORMANO - Italy
Tel(+39) 02 6140851 - Fax(+39) 02 6140339 - Email: [email protected] - www.rele.it
Page 5/8
Scheda prodotto
Elettromagneti Series NT
Type NT3
Axial Force Vs. Stroke and Duty Service
Duty Service
Stroke
ED
2 mm
5 mm 10 mm
15 mm
20 mm
100%
21 N
16 N
10 N
8N
7N
40%
27 N
20 N
13 N
10 N
9N
25%
29 N
22 N
14 N
12 N
10 N
15%
31 N
23 N
15 N
13 N
11 N
5%
40 N
29 N
18 N
15 N
13 N
Current values shown in diagrams are at rated voltage. Forces shown are referring to solenoids fed at 90% of rated voltage, with 'hot' coil and 20°C
ambient temperature.
Coil supply voltages: 12-24-110-230 VAC (50 or 60 Hz)
Insulating resistance: > 100 Mohm at 500 V DC
Dielectric strenght: 2 KV
Coil terminals: Faston 0.25 (6.35x0.8 mm) or 150 mm long leads
Total weight: 260 grams
Plunger weight: 75 grams
ITALIANA RELE' Srl. - Via dei Bravi 40 I-20032 CORMANO - Italy
Tel(+39) 02 6140851 - Fax(+39) 02 6140339 - Email: [email protected] - www.rele.it
Page 6/8
Scheda prodotto
Elettromagneti Series NT
Type NT4
Axial Force Vs. Stroke and Duty Service
Duty Service
Stroke
ED
2 mm
5 mm 10 mm
15 mm
20 mm
100%
33 N
27 N
18 N
13 N
11 N
40%
40 N
32 N
21 N
17 N
14 N
25%
43 N
34 N
24 N
18 N
15 N
15%
46 N
36 N
25 N
19 N
16 N
5%
53 N
42 N
29 N
21 N
18 N
Current values shown in diagrams are at rated voltage. Forces shown are referring to solenoids fed at 90% of rated voltage, with 'hot' coil and 20°C
ambient temperature.
Coil supply voltages: 12-24-110-230 VAC (50 or 60 Hz)
Insulating resistance: > 100 Mohm at 500 V DC
Dielectric strenght: 2 KV
Coil terminals: Faston 0.25 (6.35x0.8 mm) or 150 mm long leads
Total weight: 340 grams
Plunger weight: 110 grams
ITALIANA RELE' Srl. - Via dei Bravi 40 I-20032 CORMANO - Italy
Tel(+39) 02 6140851 - Fax(+39) 02 6140339 - Email: [email protected] - www.rele.it
Page 7/8
Scheda prodotto
Elettromagneti Series NT
Type NT5 - NEW!
Axial Force Vs. Stroke and Duty Service
Duty Service
Stroke
ED
2 mm
5 mm 10 mm 15 mm 20 mm (25 mm)
100%
48 N
38 N 28 N
22 N
18 N
9N
4N
25%
80 N
70 N 60 N
57 N
56 N
54 N
40 N
(30 mm)
All current values given in the diagrams are at rated voltage. Forces shown are referring to solenoids fed at 90% of rated voltage, with 'hot' coil and
20°C ambient temperature.
(*) Removing the retaining stop of plunger, max stroke can be extended to 30 mm.
Coil supply voltages: 12-24-110-230 VAC (50 or 60 Hz)
Max stroke: 20 mm - 30 mm (*)
Insulating resistance: > 100 Mohm at 500 V DC
Dielectric strenght: 1.5 KV
Coil terminals: Faston 0.25 (6.35x0.8 mm) or 150 mm long leads
Total weight: 4.60N (470 grams)
Plunger weight: 1,37N (140 grams)
ITALIANA RELE' Srl. - Via dei Bravi 40 I-20032 CORMANO - Italy
Tel(+39) 02 6140851 - Fax(+39) 02 6140339 - Email: [email protected] - www.rele.it
Page 8/8