Datasheet

SOLID STATE ACCESSORIES
Hockey Puck Relay Options
2–2.5°C/W
Teledyne P/ n f W151
DI n Rail Adapter
Teledyne P/ n DL12
.1°C/W
Teledyne P/ n f W108
0.3°C/W
Teledyne P/ n f W031
Mounting
Most SSRs must be mounted on heat sinks. A
large range of heat sinks is available. For heat-sink
mounting, use thermal grease or a thermal pad with
high conductibility specified by Teledyne. See our
website for additional heat sinks.
Thermal Pad
Teledyne P/ n –12
Typical Loads (Random)
HIPpak relays with random turn-on are designed for high inductive loads or phase angle control applications.
Our data sheet lists nominal current of power thyristors corresponding to a resistive load (AC-51).
Depending on the loads, check the inrush current at turn ON and possible overvoltages at turn OFF.
Main applications:
•
—AC-55b
Incandescentor infraredlamps.Inrushcurrentis generally10 timesIn duringfew10ms.Randomrelaysoftenuse in-phaseanglecontrollersor soft-starterswiththe
right control.
•
—Three-phase
AC-53
motors.2 or 3 randomturn-onrelayscan drivesuchmotors.
•
—AC-56a
Transformerloads.Very highinrushcurrentupto 100 timesIn. Use a randomturn-onSSR liketheSH.
The table below lists recommended current values for proper lifetime expectancy.
Typical Loads (Zero-Cross)
HIPpak relays with zero-cross turn-on are designed for most types of loads.
Our data sheet lists the AC-51 current value corresponding to resistive loads.
For other loads, check the inrush current at turn ON and possible overvoltages at turn OFF:
•
—AC-55b
Incandescentlamps.Inrushcurrentis generally10 timesIn duringfew10ms.
•
—AC-55a
Electricdischargelamp.These loadsoftenhaveovercurrent
at turnON andovervoltage
at turnOFF, so use 400VACSSR on 230VACmains.
•
— One-pole
AC-58 motors.These loadsoftenhaveovercurrent
at turnON andovervoltage
at turnOFF, so use 400VACSSR on 230VACmainsandadapttheSSR currentto the
starting current of the motor.
•
—Three-phase
AC-53
motors.2 or 3 SH zero-crossrelayscan drivethesemotors,butgenerallyuse E3P/E3PT or otherthree-phaserelaysor SH randomrange.
•
—AC-56a
Transformerloads.Very highinrushcurrentupto 100 timesIn. Use SH randomrelayor peakcontrolSSR.
•
—AC-56b
Capacitorloadswithveryhighcurrentat turnON andovervoltage
at turnOFF. Ourhigh-voltage
relaysare welladaptedforhighinrushcurrent.
Page 18
SSR Model
AC-53 Current
(motor)
AC-55bCurrent
(lamp)
AC-55bCurrent
(transformer)
AC-55bCurrent
(capacitor)
12A
2.5A
2.5A
0.4A
XXX
25A
5A
5A
1A
XXX
35A
9A
9A
2A
XXX
50A
12A
12A
3A
13A
75A
16A
16A
6A
24A
95A
24A
24A
9A
36A
125A
32A
32A
12A
48A
S PECI f ICATIO n S SUB j ECT TO C h Ang E WIT h OUT n OTICE
© 2010 Teledyne Relays