BE Series

MEDER electronic
BE Series
All Purpose
Reed Relays
DESCRIPTION
• Large assortment of pin out schemes
• High life expectancy
• Low thermal versions available
FEATURES
APPLICATIONS
• 6 Volt coil option
• Up to 5 switches in a package (Consult factory)
• Normally closed option
• Insulation resistance up to 1014 Ω available
• Metal and Plastic casings available
• Mercury wetted switch available
• Latching version available
• EX approved version (Intrinsically safe)
• 4.5 kVDC (3.0 kVRMS) contact to coil option
• High contact to coil voltage
• Telecommunications
• Medical equipment
• Test and Measurement
• General applications
DIMENSIONS
All dimensions in mm [inches]
www.meder.com
Germany # ++49-(0)7733-94870, USA # 800-870-5385
243
BE Series
MEDER electronic
All Purpose
Reed Relays
ORDER INFORMATION
CASING
HIGH **
OPTION
INSULATION
(P, M, V) *
RESISTANCE
XX
X
XX
66, 85, 88
10
P, M
66
11
V
66
10
M
66
11
V
1C
90
15
P, M
1E
66
14
P, M
66
20
M
66, 85, 88
20
P, M
66
23
M
RELAY
NOMINAL
CONTACT
SWITCH
SERIES
VOLTAGE
FORM
MODEL
BE
XX -
XX
XX -
05, 12, 24
1A
05, 12, 24
1B
05, 12, 24
05, 12
OPTIONS
05, 12, 24
05, 12, 24
05, 12, 24
2A
1A 1B
PIN OUT
HI
* P = plasti c, M = metal, V = Hi gh i solati on voltage
Please note: Selecti ng opti on V offers 4.5 kVD C breakdown voltage contact to coi l, but only for pi n out 11.
** Selects the 1014 Ω opti on between contact to coi l and plasti c case.
PIN OUT
www.meder.com
244
Germany # ++49-(0)7733-94870, USA # 800-870-5385
Part Number Example
BE05 - 1A85 - P
05 is the nominal voltage
1A is the contact form
85 is the switch model
P is the casing
MEDER electronic
BE Series
All Purpose
Reed Relays
RELAY DATA
All data at 20 0C
Switch Model -->
Contact For m -->
Contact Ratings
Conditions
Switching Power
Any DC combination of V & A not
to exceed their individual max.'s
Switching Voltage
Switch 66
For m A / B
Switch 85
For m A
Min. Typ. Max. Min. Typ. Max. Units
10
100
W
D C or peak A C
200
1000
V
VRMS
Switching Current
D C or peak A C
0.5
1.0
A
Carry Current
D C or peak A C
1.25
2.5
A
Static Contact Resistance
w/ 0.5V & 50mA
150
150
mΩ
Dynamic Contact Resistance
Measured w/ 0.5V & 50mA 1.5 ms
after closure
200
mΩ
Insulation Resistance
(100 Volts applied)
Across contacts
Contact to coil
10
1 0 12
10
1 0 12
Ω
Breakdown Voltage
Across contacts
Contact to coil
225
2.0 *
4000
2.0
VD C
kV D C
Operate Time, incl. Bounce
Measured w/ 100% overdrive
0.5
1.0
ms
Reset Time
Measured w/ no coil suppression
0.1
0.1
ms
Capacitance
Across contacts
Contact to coil
200
10
12
0.2
5.0
0.2
5.0
pF
1000
500
106
Cycles
Life Expectancies
Switching 5 Volts@ 10mA
DC only & <10 pF stray cap.
For other load requirements please see our life test section located
on page 151.
Environmental Data
Shock Resistance
1/2 sine wave duration 11ms
50
50
g
Vibration Resistance
From 10 - 2000 Hz
20
20
g
Ambient Temperature
10 0C/ minute max. allowable
-20
70
-20
70
0
C
Storage Temperature
10 0C/ minute max. allowable
-40
105
-40
105
0
C
Soldering Temperature
5 sec. dwell
260
0
C
260
* 4.5 kVDC / 3.0 kVRMS when the V option is selected.
www.meder.com
Germany # ++49-(0)7733-94870, USA # 800-870-5385
245
BE Series
MEDER electronic
All Purpose
Reed Relays
RELAY DATA
All data at 20 0C
Switch Model -->
Switch 88
Contact For m --> For m A / Hg wetted
Contact Ratings
Conditions
Switching Power
Any DC combination of V & A not
to exceed their individual max.'s
Switching Voltage
Min.
T yp .
Switch 90
For m C
Max. Min. Typ. Max. Units
35
3
W
D C or peak A C
1000
175
V
Switching Current
D C or peak A C
1.0
0.25
A
Carry Current
D C or peak A C
2.0
1.2
A
Static Contact Resistance
w/ 0.5V & 50mA
60
150
mΩ
Dynamic Contact Resistance
Measured w/ 0.5V & 50mA 1.5 ms
after closure
250
mΩ
Insulation Resistance
(100 Volts applied)
Across contacts
Contact to coil
10
1 0 12
10
1 0 12
Ω
Breakdown Voltage
Across contacts
Contact to coil
1500
2000
200
2000
VD C
Operate Time, incl. Bounce
Measured w/ 100% overdrive
2.5
0.7
ms
Reset Time
Measured w/ no coil suppression
2.0
1.5
ms
Capacitance
Across contacts
Contact to coil
200
10
9
0.4
5.0
1.0
5.0
pF
1000
100
106
Cycles
Life Expectancies
Switching 5 Volts@ 10mA
DC only & <10 pF stray cap.
For other load requirements please see our life test section located
on page 151.
Environmental Data
Shock Resistance
1/2 sine wave duration 11ms
50
50
g
Vibration Resistance
From 10 - 2000 Hz
20
20
g
Ambient Temperature
10 0C/ minute max. allowable
-20
55
-20
70
0
C
Storage Temperature
10 0C/ minute max. allowable
-35
105
-40
105
0
C
Soldering Temperature
5 sec. dwell
260
0
C
260
www.meder.com
246
Germany # ++49-(0)7733-94870, USA # 800-870-5385
MEDER electronic
BE Series
All Purpose
Reed Relays
COIL DATA
CONTACT
FOR M
SWITCH
MODEL
All data at 200C *
66
1A
88
85
1 B **
1C
1 E ***
66
90
66
66
2A
88
85
1A1B**
66
COIL
VOLTAGE
COIL
RESISTANCE
PULL-IN
VOLTAGE
DROP-OUT
VOLTAGE
NOMINAL
COIL
POWER
VD C
Ω
VD C
VD C
mW
Nom.
Max.
Min.
Typ.
Max.
Min.
Max.
Min.
Max.
Typ.
5
7.5
450
500
550
0.85
3.5
0.75
3.4
50
12
16
1080
1200
1320
1.9
8.4
1.8
8.3
120
24
30
2700
3000
3300
3.7
16.8
3.6
16.7
190
5
7.5
126
140
154
0.85
3.5
0.75
3.4
180
12
16
675
750
825
1.9
8.4
1.8
8.3
190
24
30
2700
3000
3300
3.7
16.8
3.6
16.7
190
5
7.5
450
500
550
0.85
3.5
0.75
3.4
50
12
16
1080
1200
1320
1.9
8.4
1.8
8.3
120
24
30
2700
3000
3300
3.7
16.8
3.6
16.7
190
5
7.5
450
500
550
0.85
3.5
0.75
3.4
50
12
16
1080
1200
1320
1.9
8.4
1.8
8.3
120
24
30
2700
3000
3300
3.7
16.8
3.6
16.7
190
5
7.5
450
500
550
0.85
3.5
0.75
3.4
50
12
16
1080
1200
1320
1.9
8.4
1.8
8.3
120
24
30
2700
3000
3300
3.7
16.8
3.6
16.7
190
5
7.5
180
200
220
0.85
3.5
0.75
3.4
125
12
16
720
800
880
1.9
8.4
1.8
8.3
180
24
30
1800
2000
2200
3.7
16.8
3.6
16.7
290
5
7.5
90
100
110
0.85
3.5
0.75
3.4
250
12
16
450
500
550
1.9
8.4
1.8
8.3
290
24
30
1440
1600
1760
3.7
16.8
3.6
16.7
360
5
7.5
90
100
110
0.85
3.5
0.75
3.4
250
12
16
450
500
550
1.9
8.4
1.8
8.3
290
24
30
1440
1600
1760
3.7
16.8
3.6
16.7
360
* The pull-in / drop-out voltage and coil resistance will change at the rate of 0.4% per degrees C.
** Reclosure of the Form B may occur if the max. voltage is exceeded. Coil polarity on Form B must be observed. Pin two is positive.
*** Coil polarity must be observed. Applying a 2 ms pulse to coil number one with nominal voltage will latch the contacts.
Applying a 2 ms pulse to coil number two will unlatch the contacts.
www.meder.com
Germany # ++49-(0)7733-94870, USA # 800-870-5385
247