MEDER electronic BE Series All Purpose Reed Relays DESCRIPTION • Large assortment of pin out schemes • High life expectancy • Low thermal versions available FEATURES APPLICATIONS • 6 Volt coil option • Up to 5 switches in a package (Consult factory) • Normally closed option • Insulation resistance up to 1014 Ω available • Metal and Plastic casings available • Mercury wetted switch available • Latching version available • EX approved version (Intrinsically safe) • 4.5 kVDC (3.0 kVRMS) contact to coil option • High contact to coil voltage • Telecommunications • Medical equipment • Test and Measurement • General applications DIMENSIONS All dimensions in mm [inches] www.meder.com Germany # ++49-(0)7733-94870, USA # 800-870-5385 243 BE Series MEDER electronic All Purpose Reed Relays ORDER INFORMATION CASING HIGH ** OPTION INSULATION (P, M, V) * RESISTANCE XX X XX 66, 85, 88 10 P, M 66 11 V 66 10 M 66 11 V 1C 90 15 P, M 1E 66 14 P, M 66 20 M 66, 85, 88 20 P, M 66 23 M RELAY NOMINAL CONTACT SWITCH SERIES VOLTAGE FORM MODEL BE XX - XX XX - 05, 12, 24 1A 05, 12, 24 1B 05, 12, 24 05, 12 OPTIONS 05, 12, 24 05, 12, 24 05, 12, 24 2A 1A 1B PIN OUT HI * P = plasti c, M = metal, V = Hi gh i solati on voltage Please note: Selecti ng opti on V offers 4.5 kVD C breakdown voltage contact to coi l, but only for pi n out 11. ** Selects the 1014 Ω opti on between contact to coi l and plasti c case. PIN OUT www.meder.com 244 Germany # ++49-(0)7733-94870, USA # 800-870-5385 Part Number Example BE05 - 1A85 - P 05 is the nominal voltage 1A is the contact form 85 is the switch model P is the casing MEDER electronic BE Series All Purpose Reed Relays RELAY DATA All data at 20 0C Switch Model --> Contact For m --> Contact Ratings Conditions Switching Power Any DC combination of V & A not to exceed their individual max.'s Switching Voltage Switch 66 For m A / B Switch 85 For m A Min. Typ. Max. Min. Typ. Max. Units 10 100 W D C or peak A C 200 1000 V VRMS Switching Current D C or peak A C 0.5 1.0 A Carry Current D C or peak A C 1.25 2.5 A Static Contact Resistance w/ 0.5V & 50mA 150 150 mΩ Dynamic Contact Resistance Measured w/ 0.5V & 50mA 1.5 ms after closure 200 mΩ Insulation Resistance (100 Volts applied) Across contacts Contact to coil 10 1 0 12 10 1 0 12 Ω Breakdown Voltage Across contacts Contact to coil 225 2.0 * 4000 2.0 VD C kV D C Operate Time, incl. Bounce Measured w/ 100% overdrive 0.5 1.0 ms Reset Time Measured w/ no coil suppression 0.1 0.1 ms Capacitance Across contacts Contact to coil 200 10 12 0.2 5.0 0.2 5.0 pF 1000 500 106 Cycles Life Expectancies Switching 5 Volts@ 10mA DC only & <10 pF stray cap. For other load requirements please see our life test section located on page 151. Environmental Data Shock Resistance 1/2 sine wave duration 11ms 50 50 g Vibration Resistance From 10 - 2000 Hz 20 20 g Ambient Temperature 10 0C/ minute max. allowable -20 70 -20 70 0 C Storage Temperature 10 0C/ minute max. allowable -40 105 -40 105 0 C Soldering Temperature 5 sec. dwell 260 0 C 260 * 4.5 kVDC / 3.0 kVRMS when the V option is selected. www.meder.com Germany # ++49-(0)7733-94870, USA # 800-870-5385 245 BE Series MEDER electronic All Purpose Reed Relays RELAY DATA All data at 20 0C Switch Model --> Switch 88 Contact For m --> For m A / Hg wetted Contact Ratings Conditions Switching Power Any DC combination of V & A not to exceed their individual max.'s Switching Voltage Min. T yp . Switch 90 For m C Max. Min. Typ. Max. Units 35 3 W D C or peak A C 1000 175 V Switching Current D C or peak A C 1.0 0.25 A Carry Current D C or peak A C 2.0 1.2 A Static Contact Resistance w/ 0.5V & 50mA 60 150 mΩ Dynamic Contact Resistance Measured w/ 0.5V & 50mA 1.5 ms after closure 250 mΩ Insulation Resistance (100 Volts applied) Across contacts Contact to coil 10 1 0 12 10 1 0 12 Ω Breakdown Voltage Across contacts Contact to coil 1500 2000 200 2000 VD C Operate Time, incl. Bounce Measured w/ 100% overdrive 2.5 0.7 ms Reset Time Measured w/ no coil suppression 2.0 1.5 ms Capacitance Across contacts Contact to coil 200 10 9 0.4 5.0 1.0 5.0 pF 1000 100 106 Cycles Life Expectancies Switching 5 Volts@ 10mA DC only & <10 pF stray cap. For other load requirements please see our life test section located on page 151. Environmental Data Shock Resistance 1/2 sine wave duration 11ms 50 50 g Vibration Resistance From 10 - 2000 Hz 20 20 g Ambient Temperature 10 0C/ minute max. allowable -20 55 -20 70 0 C Storage Temperature 10 0C/ minute max. allowable -35 105 -40 105 0 C Soldering Temperature 5 sec. dwell 260 0 C 260 www.meder.com 246 Germany # ++49-(0)7733-94870, USA # 800-870-5385 MEDER electronic BE Series All Purpose Reed Relays COIL DATA CONTACT FOR M SWITCH MODEL All data at 200C * 66 1A 88 85 1 B ** 1C 1 E *** 66 90 66 66 2A 88 85 1A1B** 66 COIL VOLTAGE COIL RESISTANCE PULL-IN VOLTAGE DROP-OUT VOLTAGE NOMINAL COIL POWER VD C Ω VD C VD C mW Nom. Max. Min. Typ. Max. Min. Max. Min. Max. Typ. 5 7.5 450 500 550 0.85 3.5 0.75 3.4 50 12 16 1080 1200 1320 1.9 8.4 1.8 8.3 120 24 30 2700 3000 3300 3.7 16.8 3.6 16.7 190 5 7.5 126 140 154 0.85 3.5 0.75 3.4 180 12 16 675 750 825 1.9 8.4 1.8 8.3 190 24 30 2700 3000 3300 3.7 16.8 3.6 16.7 190 5 7.5 450 500 550 0.85 3.5 0.75 3.4 50 12 16 1080 1200 1320 1.9 8.4 1.8 8.3 120 24 30 2700 3000 3300 3.7 16.8 3.6 16.7 190 5 7.5 450 500 550 0.85 3.5 0.75 3.4 50 12 16 1080 1200 1320 1.9 8.4 1.8 8.3 120 24 30 2700 3000 3300 3.7 16.8 3.6 16.7 190 5 7.5 450 500 550 0.85 3.5 0.75 3.4 50 12 16 1080 1200 1320 1.9 8.4 1.8 8.3 120 24 30 2700 3000 3300 3.7 16.8 3.6 16.7 190 5 7.5 180 200 220 0.85 3.5 0.75 3.4 125 12 16 720 800 880 1.9 8.4 1.8 8.3 180 24 30 1800 2000 2200 3.7 16.8 3.6 16.7 290 5 7.5 90 100 110 0.85 3.5 0.75 3.4 250 12 16 450 500 550 1.9 8.4 1.8 8.3 290 24 30 1440 1600 1760 3.7 16.8 3.6 16.7 360 5 7.5 90 100 110 0.85 3.5 0.75 3.4 250 12 16 450 500 550 1.9 8.4 1.8 8.3 290 24 30 1440 1600 1760 3.7 16.8 3.6 16.7 360 * The pull-in / drop-out voltage and coil resistance will change at the rate of 0.4% per degrees C. ** Reclosure of the Form B may occur if the max. voltage is exceeded. Coil polarity on Form B must be observed. Pin two is positive. *** Coil polarity must be observed. Applying a 2 ms pulse to coil number one with nominal voltage will latch the contacts. Applying a 2 ms pulse to coil number two will unlatch the contacts. www.meder.com Germany # ++49-(0)7733-94870, USA # 800-870-5385 247