Smart Curing System ZUV Series CSM_ZUV_series_DS_E_7_2 Cost Revolution Led by UV Curing System (Standards do not apply to all models.) • Minimal heat damage thanks to UV-LED irradiation. • New UV LEDs with much higher brightness mounted in heads. • Greater irradiation power to reduce bonding tact time. • Usage of LEDs that have a long lifetime of 40,000 hours* drastically reduces running costs. • Ultra compact body that is approximately 1/8th the size of a conventional lamp system. • Equipped with a color LCD that makes settings simple and reliable. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. * When using the ultra cooling head Refer to Safety Precautions on page 7. Product Configuration Value model ZUV-C20H Multi-function model ZUV-C30H Controller NEW head Standard head ZUV-H20MC ZUV-H30MC Value model Ultra cooling head ZUV-H10MC *1 Diffuse illumination head ZUV-H25MC Value model ZUV-H35MC Head Unit MC Series • Separate lens unit required • Cable length: 2m • Max illumination of 13,200mW/cm2 with 2-dia. beam • Separate lens unit required • Cable length: 0.3m • Max illumination of 13,200mW/cm2 with 2-dia. beam Ultra light focus lens ZUV-L2H Line beam lens ZUV-L12L • Spot dia. : 3 dia.• ZUV-L3H 4 dia.• ZUV-L4H 6 dia.• ZUV-L6H 8 dia.• ZUV-L8H 10 dia.• ZUV-L10H • Spot dia. : 2 dia. • Beam width : 12mm Side-view lens *2 ZUV-L3S/L4S/L6S/L8S/L10S • Separate lens unit required • Cable length: 2m • Max illumination of 1,100mW/cm2 with 12-dia. beam Diffusing lens ZUV-L12H • Separate lens unit required • Cable length: 0.3m • Max illumination of 1,100mW/cm2 with 12-dia. beam Line beam lens ZUV-L15L Extension cable ZUV-XC2B/XC5B/XC10B • Beam width : 15mm • For extending length between controller and heads • Cable length: 2m ZUV-XC2B 5m ZUV-XC5B 10m ZUV-XC10B Lens Unit Spot lens ZUV-L3H/L4H/L6H/L8H/L10H • Separate lens unit required • Cable length: 0.3m • Max illumination of 13,200mW/cm2 with 2-dia. beam *1 Model is also available with 2-m cable. (ZUV-H10MC 2M) • Spot dia. : 3 dia.• ZUV-L3S 4 dia.• ZUV-L4S 6 dia.• ZUV-L6S 8 dia.• ZUV-L8S 10 dia.• ZUV-L10S • Spot dia. : 12 dia. *2 When using ZUV-H25MC/H35MC diffuse illumination head with side-view lens, we recommend using ZUV-L3S/L4S. 1 ZUV Series Ordering Information Controller Type Model ZUV-C20H ZUV-C30H Value model Multi-function model Head Unit * N E W Type Cable length Value model Standard head − 0.3 m 0.3 m Ultra cooling head 2m Diffuse illumination head Value model − Model ZUV-H20MC 2M ZUV-H30MC 0.3M ZUV-H10MC 0.3M ZUV-H10MC 2M ZUV-H25MC 2M ZUV-H35MC 0.3M 2m 2m 0.3 m * 365 - nm light source wavelength. Models are also available with a 385-nm light source wavelength. (Standard head: ZUV-H21MC 2M/H11MC 2M, diffuse illumination head: ZUV-H26MC 2M) Lens Unit Type Spot Spot dia.: 3 mm Spot dia.: 4 mm Spot lens Spot dia.: 6 mm Spot dia.: 8 mm Spot dia.: 10 mm Ultra light focus lens Spot dia.: 2 mm Beam width: 12 mm Line beam lens Beam width: 15 mm Spot dia.: 3 mm Spot dia.: 4 mm Side-view lens * Spot dia.: 6 mm Spot dia.: 8 mm Spot dia.: 10 mm Diffusing lens (for diffuse illumination head) Spot dia.: 12 mm Model ZUV-L3H ZUV-L4H ZUV-L6H ZUV-L8H ZUV-L10H ZUV-L2H ZUV-L12L ZUV-L15L ZUV-L3S ZUV-L4S ZUV-L6S ZUV-L8S ZUV-L10S ZUV-L12H * When using ZUV-H25MC/H35MC diffuse illumination head with side-view lens, we recommend using ZUV-L3S/L4S. For Extending Length between Controller and Heads Type Cable length 2m Extension cable 5m 10 m Model ZUV-XC2B ZUV-XC5B ZUV-XC10B 2 ZUV Series Ratings and Specifications Controller Model Irradiation method Constant irradiation Pattern irradiation No. of settings Cumulative Irradiation Terminal block I/O Input Output ZUV-C20H (Value model) Irradiation power (0% to100%), Irradiation time (max. 99.9s/unlimited) Unavailable No bank feature Time (unit: 100 hour display) Emergency stop, UV illumination start/stop (all channels/4 channels) Ready (all channels/4 channels), error, operating life RS-232C and USB I/O None Cooling method Natural air cooling (no fan) Power supply voltage AC power only 100V-240V AC ± 10%, 50/60 Hz (AC adapter attached) * ZUV-C30H (Multi-function model) Irradiation power (0% to 100%), Irradiation time (999.9 s max./unlimited) Can be set to step or ramp (linear) (16 points specified per setting) Applicable Heads: ZUV-H Series 16 banks Energy (display unit - J) Emergency stop, start/stop UV irradiation (4 channels), select settings (banks) Ready (4 channels), UV irradiating, errors Start/stop UV irradiation (4 channels), select settings (banks),get/change settings data, save/read data, power tuning Natural air cooling Select AC or DC power supply • AC power supply: 100 to 240 V AC±10%, 50/60 Hz (AC adapter included) • DC power supply: 24 V DC±10% (supplied from terminal block on back of unit) • With AC adapter: 1.5 A (36VA) • With DC power supply: 1.5 A (36VA) Vibration resistance 10 to 150 Hz (acceleration 50 m/s2) with a 0.35 mm single amplitude for 8 minutes each in X, Y, and Z directions, 10 times Shock resistance 150 m/s2 in 6 directions (up/down, right/left, front/back) 3 times each Ambient temperature range Operating: 5 to 35°C; Storage: -10 to 60°C (with no condensation or icing) Ambient humidity range Operating/storage: 30% to 85% (with no condensation or icing) Degree of protection IEC 60529 IP20 Material Polycarbonate, SECC SUS, aluminum Weight (package state) Approx. 1,800g (Controller: approx. 1,200g) Approx. 2,600g (Controller: approx. 1,800g) Instruction sheet, key, AC adapter, CD-ROM (USB Accessories Instruction sheet, key, AC adapter driver, user's manual PDF, quick setting guide PDF) Current consumption 1.4A (53W) * The power cord that is included as standard is designed for use with 100 VAC (Japanese specifications). Head Unit Model Light source Wavelength Class Vibration resistance Shock resistance Ambient temperature range Ambient humidity range Degree of Protection Material Weight (packed state) Accessories ZUV-H20MC/H30MC/H10MC/H25MC/H35MC 365nm * Class 3B (JIS C 6802: 2005) Class 3B (EN60825-1: 1994 +A1: 2002 +A2: 2001) 10 to 150 Hz (acceleration 50 m/s2) with a 0.35 mm single amplitude for 8 minutes each in X, Y, and Z directions, 10 times 150 m/s2 in 6 directions (up/down, right/left, front/back), 3 times each Operating: 5 to 35°C; Storage: -10 to 60°C (with no condensation or icing) Operating/storage: 30% to 85% (with no condensation or icing) IEC60529 IP40 ZUV-H20MC/25MC:Zinc, aluminum, glass ZUV-H30MC/H10MC/H35MC:Zinc, copper, aluminum, glass ZUV-H20MC/H25MC:Approx. 185g (Head unit: approx. 100g), ZUV-H30MC/H35MC:Approx. 150g (Head unit: approx. 55g), ZUV-H10MC 0.3M :Approx. 180g (Head unit:approx. 105g), ZUV-H10MC 2M :Approx. 235g (Head unit:approx. 160g) Instruction sheet, mounting brackets (with M3 screws), warning labels (in English) * Models are also available with a 385-nm light source wavelength. (Standard head:ZUV-H21MC 2M/H11MC 2M, diffuse illmination head:ZUV-H26MC 2M) 3 ZUV Series Lens Unit Model ZUV-L2H/L3H/L4H/L6H/L8H/L10H/L12L/L15L/L3S/L4S/L6S/L8S/L10S/L12H Vibration resistance 10 to 150 Hz (acceleration 50 m/s2) with a 0.35 mm single amplitude for 8 minutes each in X, Y, and Z directions, 10 times Shock resistance 150 m/s2, in 6 directions (up/down, right/left, front/back) , 3 times each Ambient temperature range Operating: 5 to 35°C; Storage: -10 to 60°C (with no condensation or icing) Ambient humidity range Operating/storage: 30% to 85% (with no condensation or icing) Degree of Protection IEC60529 IP40 Material Aluminum, glass Weight (package) ZUV-L2H/L3H/L4H/L6H/L8H/L10H: Approx. 10g (Lens unit: approx. 5g), ZUV-L12L/L15L : Approx. 30g (Lens unit: approx. 5g), ZUV-L3S/L4S/L6S/L8S/L10S : Approx. 35g (Lens unit: approx. 5g), ZUV-L12H : Approx. 30g (Lens unit: approx. 5g) Accessories Instruction sheet When using the standard head Ultra light focus lens/Spot lens/Line beam lens Head unit model ZUV-H20MC/H30MC/H10MC Lens unit model ZUV-L2H ZUV-L3H ZUV-L4H ZUV-L6H ZUV-L8H ZUV-L10H ZUV-L12L Spot diameter/Beam shape 2 dia. 3 dia. 4 dia. 6 dia. 8 dia. 10 dia. 12 × 2mm Recommended working distance 10mm Peak illumination *1 10mm 2 15mm 2 20mm 2 7,200mW/cm 4,500mW/cm 20mm 2 13,200mW/cm 8,600mW/cm 2,200mW/cm Lens unit model ZUV-L3S ZUV-L4S ZUV-L6S ZUV-L8S ZUV-L10S Spot diameter 3 dia. 4 dia. 6 dia. 8 dia. 10 dia. Recommended working distance 4mm 5mm 8mm 13mm 5mm Peak illumination *1 8,300mW/cm2 6,400mW/cm2 4,200mW/cm2 2,100mW/cm2 660mW/cm2 30mm 2 15mm 2 760mW/cm 1,500mW/cm2 Side-view lens Head unit model ZUV-H20MC/H30MC/H10MC When using the diffuse Illmination head Diffusing lens/Side-view lens/Line Beam lens Head unit model ZUV-H25MC/H35MC Lens unit model ZUV-L12H ZUV-L3S ZUV-L4S ZUV-L15L Spot diameter/Beam shape 12 dia. 3 dia. 4 dia. 15 × 3mm Recommended working distance 30mm Peak illumination *1 8mm 2 1,100mW/cm 13mm 2 5,400mW/cm 15mm 2 3,000mW/cm 770mW/cm2 *1. Under the following conditions: 100% irradiation power, 25°C room temperature, and with heat sink. Values for reference only. The illumination varies depending on factors such as the amiant environment, installation conditions, the service life of part, and differences between parts. Continually check the curing status to ensure that there is room for error in the illumination. Refer to Beam Spot Profiles (Typical Examples) on page 5 for design information. 4 ZUV Series Engineering Data (Reference Value) Beam Spot Profiles (Typical Examples) Standard head /ultra cooling head (Controller ZUV-C20H/C30H, at 100% irradiation power) 13000 WD=10 WD=12 WD=14 WD=16 WD=20 12000 11000 10000 9000 8000 Spot lens ZUV-L3H Illumination profile Illumination (mW/cm2) Illumination (mW/cm2) Ultra light focus lens ZUV-L2H Illumination profile 9000 WD=8 WD=11 WD=13 WD=16 WD=20 8000 7000 6000 7000 5000 6000 4000 5000 3000 4000 3000 2000 2000 1000 1000 0 -5 -4 -3 -2 -1 0 1 2 0 -5 3 4 5 Position (mm) WD=10 WD=14 WD=20 WD=25 WD=30 5000 4000 -3 -2 -1 0 1 2 3 4 5 Position (mm) Spot lens ZUV-L6H Illumination profile Illumination (mW/cm2) Illumination (mW/cm2) Spot lens ZUV-L4H Illumination profile 6000 -4 4500 WD=10 WD=15 WD=20 WD=25 WD=30 4000 3500 3000 2500 3000 2000 2000 1500 1000 1000 500 0 -5 -4 -3 -2 -1 0 1 2 0 -5 3 4 5 Position (mm) WD=10 WD=15 WD=20 WD=25 WD=30 2000 -3 -2 -1 0 1 2 3 4 5 Position (mm) Spot lens ZUV-L10H Illumination profile Illumination (mW/cm2) Illumination (mW/cm2) Spot lens ZUV-L8H Illumination profile 2500 -4 1500 800 WD=10 WD=15 WD=20 WD=25 WD=30 WD=50 700 600 500 400 1000 300 200 500 100 -4 -3 -2 -1 0 1 2 0 -10 3 4 5 Position (mm) -8 -6 -4 -2 0 2 4 6 8 10 Position (mm) Side-view lens ZUV-L3S Illumination profile Side-view lensZUV-L4S Illumination profile 8000 6000 WD=4 WD=5 WD=10 WD=15 WD=20 7000 6000 5000 Illumination (mW/cm2) Illumination (mW/cm2) 0 -5 WD=4 WD=5 WD=10 WD=15 WD=20 5000 4000 3000 4000 3000 2000 2000 1000 1000 0 -5 -4 -3 -2 -1 0 1 2 3 4 5 Position (mm) 0 -5 -4 -3 -2 -1 0 1 2 3 4 5 Position (mm) Note: 1. WD is setting distance to a workpiece from a lens unit end face. Note: 2. The illumination profile varies depending on factors such as the ambient environment, installation conditions, the service life of part, and differences between parts. Continually check the curing status of the resin to ensure that there is room for error in the illumination profile. 5 Side-view lens ZUV-L6S Illumination profile Side-view lens ZUV-L8S Illumination profile 4000 2200 WD=5 WD=8 WD=10 WD=15 WD=20 3500 3000 2500 Illumination (mW/cm2) Illumination (mW/cm2) ZUV Series WD=5 WD=10 WD=15 WD=18 WD=20 2000 1800 1600 1400 1200 2000 1000 1500 800 600 1000 400 500 0 -5 200 -4 -3 -2 -1 0 1 2 0 -5 3 4 5 Position (mm) 500 600 200 400 100 200 -4 -2 0 2 4 1400 WD=10 WD=15 WD=20 WD=30 1200 0 -10 6 8 10 Position (mm) Line beam lens ZUV-L12L Illumination profile (width direction) 1000 800 600 0 1 2 3 4 5 Position (mm) WD=10 WD=15 WD=20 WD=30 1000 300 -6 -1 1200 800 -8 -2 1400 400 0 -10 Illumination (mW/cm2) Illumination (mW/cm2) 600 -8 -6 -4 -2 0 2 4 6 8 10 Position (mm) Diffuse illumination head ZUV-H25MC/H35MC (Controller ZUV-C20H/C30H, at 100% irradiation) Diffusing lens ZUV-L12H Illumination profile Illumination (mW/cm2) Illumination (mW/cm2) WD=5 WD=10 WD=15 WD=20 WD=25 WD=30 WD=50 -3 Line beam lens ZUV-L12L Illumination profile (length direction) Side-view lens ZUV-L10S Illumination profile 700 -4 1000 WD=10 WD=15 WD=20 WD=25 WD=30 WD=50 900 800 700 600 500 400 400 200 0 -5 300 200 -4 -3 -2 -1 0 1 2 3 4 5 Position (mm) 100 0 -10 1200 WD=5 WD=10 WD=15 WD=20 WD=30 1000 800 400 200 200 -6 -3 0 3 6 9 12 15 Position (mm) 0 2 4 6 8 10 Position (mm) WD=5 WD=10 WD=15 WD=20 WD=30 800 400 -9 -2 1000 600 -12 -4 1200 600 0 -15 -6 Line beam lens ZUV-L15L Illumination profile (width direction) Illumination (mW/cm2) Illumination (mW/cm2) Line beam lens ZUV-L15L Illumination profile (length direction) -8 0 -5 -4 -3 -2 -1 0 1 2 3 4 5 Position (mm) Note: 1. WD is setting distance to a workpiece from a lens unit end face. Note: 2. The illumination profile varies depending on factors such as the ambient environment, installation conditions, the service life of part, and differences between parts. Continually check the curing status of the resin to ensure that there is room for error in the illumination profile. 6 ZUV Series Safety Precautions Refer to Warranty and Limitatious of Liability. Controller WARNING Damage or fire may occur. Do not exceed the rated voltage. PRECAUTIONS FOR SAFE USE Observe the following precautions to ensure safe operation. 1. Do not use the product in atmospheres containing flammable or explosive gases. 2. Do not install the product close to high-voltage devices and/ or power devices in order to secure the safety of operations and maintenance. 3. If you use an AC power supply, use the enclosed AC adapter (100 to 240 VAC ± 10%). 4. If you use a DC power supply, do not use a power supply that exceeds the rated voltage (24 VDC ± 10%). Also, do not reverse the polarity when you connect the power supply. Recommended power supply: OMRON S8VS-18024 (24 VDC, 7.5 A) 5. Do not short-circuit the load of an open-collector output. 6. Do not exceed the rated load. 7. Lay the product cable away from any high-voltage cable or power line. If laid in the same conduit or duct, induction noise from them may caused malfunction or breakdown of the product. 8. In the event of smoke, excessive heat of the cover or strange smell out of the product, immediately stop operation of the product, turn OFF the power supply, and disconnect the plug from the outlet. As repair by the customer is dangerous, contact an OMRON's local office or sales office. 9. Do not try to disassemble, repair, or modify the product. Doing so may result in malfunctions, causing fire or electric shock. 10. Dispose this product as industrial waste. 11. Do not drop this product. In the event of dropping or breaking the product, turn OFF the power supply, disconnect the power plug from the outlet, and then contact an OMRON's local office or sales office. Doing so may result in fire. 12. Do not put foreign material into a vent hole. Doing so may result in fire or electric shock. 13. Do not closely contact or pile up controllers. Doing so may result in fire or faults. PRECAUTIONS FOR CORRECT USE 1. Avoid installing the product in the following places: • Places exceeding the rated ambient temperature • Places exposed to extreme temperature changes (prevent condensation) • Places where RH levels are outside the range 35% to 85% • Places subject to corrosive or flammable gases • Places subject to dust (including iron dust), or salts • Places subject to direct shock or vibration • Places subject to disturbance light such as ultraviolet (UV), laser beam, welding arc • Places subject to direct sunlight or places close to heaters • Places subject to exposure to water, oil, or chemicals, or subject to mist • Places subject to strong magnetic field or electric field 2. Power supply and wiring • When using the product, make sure FG (frame ground terminal) is connected. • If you use a DC power supply, ground the power supply. • If you use a DC power supply, observe the following precautions. - If you use a commercially available switching regulator, ground the FG terminal. - If there is surge on the power line, connect a surge absorber that is suitable for the application environment. - Before you turn ON the power supply after wiring, confirm that the power supply is wired correctly, make sure that the load is not short-circuited, and make sure that the load current is suitable. • If you use the AC adapter, connect the power plug to the Controller first and then plug the power cord into the outlet. •When you disconnect the AC adapter, disconnect the power cord from the outlet first and then disconnect it from the Controller. •When you connect or disconnect the Head Unit, make sure that you do so with the power supply turned OFF. •Use only the combinations of the Head Unit and Controller that are given in this datasheet. •You can use one of the special Extension Cables to extend the cable length between a Head Unit and Controller, but you cannot connect more than one Extension Cable together. 3. Cleaning • Avoid the use of thinner, benzine, acetone, and kerosene. Use of these solvents will melt the surface of the device. • Use commercially available alcohol. • Wipe out small dirt or dust carefully not to damage the lens using a soft cloth (such as a lens cleaner) containing a small quantity of alcohol. 4. Resin cure State of resin cure changes depending on various factors. Continuously check the state of resin cure to set at the best condition. 5. Replacing the head When you replace the Head Unit, always initialize the applicable channel in the Controller. If you do not initialize the channel, the previous Head Unit information (e.g., cumulative irradiation energy and power tuning data) will remain and the new Head Unit will not function correctly. 6. Connecting the head If you disconnect a Head Unit and then reconnect it, always connect it to the same channel. If you connect a Head Unit to a different channel, the specific Head Unit information (e.g., cumulative irradiation energy and power tuning data) will not be inherited and the Head Unit will not function correctly. 7. LED safety measures As connected with the head, the unit generates UV that is classified as Class 3B, so, this controller provides functions such as safety key lock function. Use these functions according to requirements specified in JIS C 6802. Installing the controller ZUV-C20H 80mm Front Rear 50mm 80mm ZUV-C30H 80mm Rear Front 50mm 80mm 7 ZUV Series Safety Precautions Head Unit WARNING Direct exposure of eye or skin to ultraviolet light will damage eyesight or the skin. Never look into or expose the body to the ultraviolet light. Work wearing protection glasses and protection equipment if exposure to the reflected ultraviolet light is considered. 5. Mounting of the head Make sure to use attached mounting bracket for the head part. Use the bracket within the specified mounting range. Misuse of the mounting bracket may raise the temperature rise of the head and shorten the usage life of LED. Electric shock or leaked light may cause injury or damage to the product. Never disassemble the product. CAUTION Touching the product may result in burns. Do not touch the product while energized or immediately after turning OFF the power supply. PRECAUTIONS FOR SAFE USE Observe the following precautions to ensure safe operation. 1. Do not use the product in atmospheres containing flammable or explosive gases. 2. Do not try to disassemble, repair, or modify this product. 3. Dispose of this product as industrial waste. 4. Do not touch the head lens for a long time during ultraviolet light irradiation. Doing so may result in burns. 5. Do a special medical check-up, based on "Notice No.308" of Ministry of Health, Labour and Welfare, for workers handling this product. 6. Be sure to use the attached mounting bracket to fix the head part. Use the bracket within the specified mounting range. Misuse of the mounting bracket may raise the head temperature, causing burns. PRECAUTIONS FOR CORRECT USE 1. Avoid installing the product in the following places: • Places exposed to strong electromagnetic fields • Places where the lens in front of the head may be exposed to dust, oil, or dew condensation. • Places subject to corrosive gases • Places where the product is exposed to direct shock or vibration. 2. Wiring • Keep the cable between the head and the controller away from high-voltage cables or power lines. If laid in the same duct, induction noise from them may cause malfunction or breakdown of the product. • Be sure to turn OFF the power supply when mounting or demounting the head part. • An extension cable can be used between head and the controller. Do not use extended multiple cables. 3. Cleaning • Avoid the use of thinner, benzine, acetone, and kerosene. Use of these solvents will melt the surface of the product. • Use commercially available alcohol. • Wipe out small dirt or dust carefully not to damage the lens using a soft cloth (such as a lens cleaner) containing a small quantity of alcohol. 4. Resin cure State of resin cure changes depending on various factors. Continuously check the state of resin cure to set at the best condition. 8 ZUV Series Dimensions (Unit: mm) Controller Value model ZUV-C20H 85 Multi-function model ZUV-C30H 2.5 146 Four, 14-dia. 24.5 23.6 15.45 head connector 85 105 Four, 14-dia. 21.5 30.8 13.1 9.7 head connector 10.1 146 106.6 30.8 80 37.4 21 3 15.7 18.6 18.6 61 18.6 6.1 57.4 31.6 2.5 6.6 18.6 12.6 56.6 125 30 27 36 81.6 28.4 55 125 3.5 85 4.1 12.7 49 6 12.7 12.7 12.7 26 Head Unit Mounting Bracket Standard head (When attached to spot lens) Value model ZUV-H20MC 2000 54.6 11.1 12 dia. Two, M4 x valid depth 6 20 ZUV-H30MC 300 54.6 11.1 43 12 dia. 43 13 14.7 dia. 14.7 dia. 5 dia. 12 . dia 21.5 26 5 dia. Lens unit Lens unit 20 20 40 2 Ultra cooling head ZUV-H10MC 300 126.6 43 11.1 12 dia. 14.7 dia. 5 dia. Lens unit Diffuse illumination head (When attached to ZUV-L12H) Value model ZUV-H25MC 51.2 ZUV-H35MC 43 2000 51.2 7.7 12 dia. 43 300 7.7 12 dia. 14.7 dia. 14.7 dia. 5 dia. 5 dia. Lens unit Lens unit Lens Unit Spot lens ZUV-L3H/L4H/L6H/L8H/L10H Ultra light focus lens ZUV-L2H Note: The model number is printed on the side of the Lens unit. 11.1 4.4 3.5 12 dia. 19.1 2.6 12 dia. 11.1 1.7 62.6 ZUV-L3H/L4H/L6H/L8H 2000 43 19.1 ZUV-L10H 14.7 dia. 5 dia. Line beam lens ZUV-L12L 15.1 1 12 dia. 58.6 15.1 Lens unit ZUV-L15L 2000 54.5 11 43 Note: When attached to ZUV-H20MC (Standard head value model) 11 12 dia. 1.5 2000 43 14.7 dia. 14.7 dia. 5 dia. 5 dia. Lens unit Lens unit Note: When attached to ZUV-H25MC (Diffuse illumination head value model) Note: When attached to ZUV-H20MC (Standard head value model) Side-view lens ZUV-L_S Diffusing lens ZUV-L12H 22.7 12 dia. 7 0.8 0.8 66.2 Note: The model number is printed on the side of the lens unit. 12 dia. 2000 51.2 43 7.7 12 dia. 43 2000 7.7 22.7 14.7 dia. 14.7 dia. 5 dia. Lens unit Note: When attached to ZUV-H20MC (Standard head value model) 5 dia. Lens unit Note: When attached to ZUV-H25MC (Diffuse illumination head value model) 9 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2016.2 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2016 All Right Reserved.