Smart Curing System
ZUV Series
CSM_ZUV_series_DS_E_7_2
Cost Revolution Led by UV Curing
System
(Standards do not
apply to all models.)
• Minimal heat damage thanks to UV-LED irradiation.
• New UV LEDs with much higher brightness mounted in
heads.
• Greater irradiation power to reduce bonding tact time.
• Usage of LEDs that have a long lifetime of 40,000
hours* drastically reduces running costs.
• Ultra compact body that is approximately 1/8th the size
of a conventional lamp system.
• Equipped with a color LCD that makes settings simple
and reliable.
For the most recent information on models that have been
certified for safety standards, refer to your OMRON website.
* When using the ultra cooling head
Refer to Safety Precautions on page 7.
Product Configuration
Value model
ZUV-C20H
Multi-function model
ZUV-C30H
Controller
NEW
head
Standard head
ZUV-H20MC
ZUV-H30MC
Value model
Ultra cooling head
ZUV-H10MC *1
Diffuse illumination head
ZUV-H25MC
Value model
ZUV-H35MC
Head Unit
MC
Series
• Separate lens unit required
• Cable length: 2m
• Max illumination of
13,200mW/cm2 with 2-dia.
beam
• Separate lens unit required
• Cable length: 0.3m
• Max illumination of
13,200mW/cm2 with 2-dia.
beam
Ultra light focus lens
ZUV-L2H
Line beam lens
ZUV-L12L
• Spot dia. :
3 dia.• ZUV-L3H
4 dia.• ZUV-L4H
6 dia.• ZUV-L6H
8 dia.• ZUV-L8H
10 dia.• ZUV-L10H
• Spot dia. : 2 dia.
• Beam width : 12mm
Side-view lens *2
ZUV-L3S/L4S/L6S/L8S/L10S
• Separate lens unit required
• Cable length: 2m
• Max illumination of
1,100mW/cm2 with 12-dia.
beam
Diffusing lens
ZUV-L12H
• Separate lens unit required
• Cable length: 0.3m
• Max illumination of
1,100mW/cm2 with 12-dia.
beam
Line beam lens
ZUV-L15L
Extension cable
ZUV-XC2B/XC5B/XC10B
• Beam width : 15mm
• For extending length between
controller and heads
• Cable length: 2m ZUV-XC2B
5m ZUV-XC5B
10m ZUV-XC10B
Lens Unit
Spot lens
ZUV-L3H/L4H/L6H/L8H/L10H
• Separate lens unit required
• Cable length: 0.3m
• Max illumination of
13,200mW/cm2 with 2-dia.
beam
*1 Model is also available with 2-m cable. (ZUV-H10MC 2M)
• Spot dia. :
3 dia.• ZUV-L3S
4 dia.• ZUV-L4S
6 dia.• ZUV-L6S
8 dia.• ZUV-L8S
10 dia.• ZUV-L10S
• Spot dia. : 12 dia.
*2 When using ZUV-H25MC/H35MC diffuse illumination head with side-view lens,
we recommend using ZUV-L3S/L4S.
1
ZUV Series
Ordering Information
Controller
Type
Model
ZUV-C20H
ZUV-C30H
Value model
Multi-function model
Head Unit *
N E W
Type
Cable length
Value model
Standard head
−
0.3 m
0.3 m
Ultra cooling head
2m
Diffuse illumination head
Value model
−
Model
ZUV-H20MC 2M
ZUV-H30MC 0.3M
ZUV-H10MC 0.3M
ZUV-H10MC 2M
ZUV-H25MC 2M
ZUV-H35MC 0.3M
2m
2m
0.3 m
* 365 - nm light source wavelength. Models are also available with a 385-nm light source wavelength.
(Standard head: ZUV-H21MC 2M/H11MC 2M, diffuse illumination head: ZUV-H26MC 2M)
Lens Unit
Type
Spot
Spot dia.: 3 mm
Spot dia.: 4 mm
Spot lens
Spot dia.: 6 mm
Spot dia.: 8 mm
Spot dia.: 10 mm
Ultra light focus lens
Spot dia.: 2 mm
Beam width: 12 mm
Line beam lens
Beam width: 15 mm
Spot dia.: 3 mm
Spot dia.: 4 mm
Side-view lens *
Spot dia.: 6 mm
Spot dia.: 8 mm
Spot dia.: 10 mm
Diffusing lens (for diffuse illumination head)
Spot dia.: 12 mm
Model
ZUV-L3H
ZUV-L4H
ZUV-L6H
ZUV-L8H
ZUV-L10H
ZUV-L2H
ZUV-L12L
ZUV-L15L
ZUV-L3S
ZUV-L4S
ZUV-L6S
ZUV-L8S
ZUV-L10S
ZUV-L12H
* When using ZUV-H25MC/H35MC diffuse illumination head with side-view lens, we recommend using ZUV-L3S/L4S.
For Extending Length between Controller and Heads
Type
Cable length
2m
Extension cable
5m
10 m
Model
ZUV-XC2B
ZUV-XC5B
ZUV-XC10B
2
ZUV Series
Ratings and Specifications
Controller
Model
Irradiation
method
Constant
irradiation
Pattern
irradiation
No. of settings
Cumulative Irradiation
Terminal
block I/O
Input
Output
ZUV-C20H (Value model)
Irradiation power (0% to100%),
Irradiation time (max. 99.9s/unlimited)
Unavailable
No bank feature
Time (unit: 100 hour display)
Emergency stop, UV illumination start/stop
(all channels/4 channels)
Ready (all channels/4 channels), error, operating life
RS-232C and USB I/O
None
Cooling method
Natural air cooling (no fan)
Power supply voltage
AC power only
100V-240V AC ± 10%, 50/60 Hz
(AC adapter attached) *
ZUV-C30H (Multi-function model)
Irradiation power (0% to 100%),
Irradiation time (999.9 s max./unlimited)
Can be set to step or ramp (linear)
(16 points specified per setting)
Applicable Heads: ZUV-H Series
16 banks
Energy (display unit - J)
Emergency stop, start/stop UV irradiation
(4 channels), select settings (banks)
Ready (4 channels), UV irradiating, errors
Start/stop UV irradiation (4 channels),
select settings (banks),get/change settings data,
save/read data, power tuning
Natural air cooling
Select AC or DC power supply
• AC power supply: 100 to 240 V AC±10%,
50/60 Hz (AC adapter included)
• DC power supply: 24 V DC±10%
(supplied from terminal block on back of unit)
• With AC adapter: 1.5 A (36VA)
• With DC power supply: 1.5 A (36VA)
Vibration resistance
10 to 150 Hz (acceleration 50 m/s2) with a 0.35 mm single amplitude for 8 minutes each in
X, Y, and Z directions, 10 times
Shock resistance
150 m/s2 in 6 directions (up/down, right/left, front/back) 3 times each
Ambient temperature range Operating: 5 to 35°C; Storage: -10 to 60°C (with no condensation or icing)
Ambient humidity range
Operating/storage: 30% to 85% (with no condensation or icing)
Degree of protection
IEC 60529 IP20
Material
Polycarbonate, SECC
SUS, aluminum
Weight (package state)
Approx. 1,800g (Controller: approx. 1,200g)
Approx. 2,600g (Controller: approx. 1,800g)
Instruction sheet, key, AC adapter, CD-ROM (USB
Accessories
Instruction sheet, key, AC adapter
driver, user's manual PDF, quick setting guide PDF)
Current consumption
1.4A (53W)
* The power cord that is included as standard is designed for use with 100 VAC (Japanese specifications).
Head Unit
Model
Light
source
Wavelength
Class
Vibration resistance
Shock resistance
Ambient temperature
range
Ambient humidity range
Degree of Protection
Material
Weight (packed state)
Accessories
ZUV-H20MC/H30MC/H10MC/H25MC/H35MC
365nm *
Class 3B (JIS C 6802: 2005) Class 3B (EN60825-1: 1994 +A1: 2002 +A2: 2001)
10 to 150 Hz (acceleration 50 m/s2) with a 0.35 mm single amplitude for 8 minutes each in
X, Y, and Z directions, 10 times
150 m/s2 in 6 directions (up/down, right/left, front/back), 3 times each
Operating: 5 to 35°C;
Storage: -10 to 60°C (with no condensation or icing)
Operating/storage: 30% to 85% (with no condensation or icing)
IEC60529 IP40
ZUV-H20MC/25MC:Zinc, aluminum, glass
ZUV-H30MC/H10MC/H35MC:Zinc, copper, aluminum, glass
ZUV-H20MC/H25MC:Approx. 185g (Head unit: approx. 100g),
ZUV-H30MC/H35MC:Approx. 150g (Head unit: approx. 55g),
ZUV-H10MC 0.3M :Approx. 180g (Head unit:approx. 105g),
ZUV-H10MC 2M
:Approx. 235g (Head unit:approx. 160g)
Instruction sheet, mounting brackets (with M3 screws), warning labels (in English)
* Models are also available with a 385-nm light source wavelength. (Standard head:ZUV-H21MC 2M/H11MC 2M, diffuse illmination head:ZUV-H26MC 2M)
3
ZUV Series
Lens Unit
Model
ZUV-L2H/L3H/L4H/L6H/L8H/L10H/L12L/L15L/L3S/L4S/L6S/L8S/L10S/L12H
Vibration resistance
10 to 150 Hz (acceleration 50 m/s2) with a 0.35 mm single amplitude for 8 minutes each in X, Y, and Z directions,
10 times
Shock resistance
150 m/s2, in 6 directions (up/down, right/left, front/back) , 3 times each
Ambient temperature range
Operating: 5 to 35°C; Storage: -10 to 60°C (with no condensation or icing)
Ambient humidity range
Operating/storage: 30% to 85% (with no condensation or icing)
Degree of Protection
IEC60529 IP40
Material
Aluminum, glass
Weight (package)
ZUV-L2H/L3H/L4H/L6H/L8H/L10H: Approx. 10g (Lens unit: approx. 5g),
ZUV-L12L/L15L
: Approx. 30g (Lens unit: approx. 5g),
ZUV-L3S/L4S/L6S/L8S/L10S
: Approx. 35g (Lens unit: approx. 5g),
ZUV-L12H
: Approx. 30g (Lens unit: approx. 5g)
Accessories
Instruction sheet
When using the standard head
Ultra light focus lens/Spot lens/Line beam lens
Head unit model
ZUV-H20MC/H30MC/H10MC
Lens unit model
ZUV-L2H
ZUV-L3H
ZUV-L4H
ZUV-L6H
ZUV-L8H
ZUV-L10H
ZUV-L12L
Spot diameter/Beam shape
2 dia.
3 dia.
4 dia.
6 dia.
8 dia.
10 dia.
12 × 2mm
Recommended working
distance
10mm
Peak illumination *1
10mm
2
15mm
2
20mm
2
7,200mW/cm
4,500mW/cm
20mm
2
13,200mW/cm
8,600mW/cm
2,200mW/cm
Lens unit model
ZUV-L3S
ZUV-L4S
ZUV-L6S
ZUV-L8S
ZUV-L10S
Spot diameter
3 dia.
4 dia.
6 dia.
8 dia.
10 dia.
Recommended working
distance
4mm
5mm
8mm
13mm
5mm
Peak illumination *1
8,300mW/cm2
6,400mW/cm2
4,200mW/cm2
2,100mW/cm2
660mW/cm2
30mm
2
15mm
2
760mW/cm
1,500mW/cm2
Side-view lens
Head unit model
ZUV-H20MC/H30MC/H10MC
When using the diffuse Illmination head
Diffusing lens/Side-view lens/Line Beam lens
Head unit model
ZUV-H25MC/H35MC
Lens unit model
ZUV-L12H
ZUV-L3S
ZUV-L4S
ZUV-L15L
Spot diameter/Beam shape
12 dia.
3 dia.
4 dia.
15 × 3mm
Recommended working
distance
30mm
Peak illumination *1
8mm
2
1,100mW/cm
13mm
2
5,400mW/cm
15mm
2
3,000mW/cm
770mW/cm2
*1. Under the following conditions: 100% irradiation power, 25°C room temperature, and with heat sink. Values for reference only.
The illumination varies depending on factors such as the amiant environment, installation conditions, the service life of part,
and differences between parts.
Continually check the curing status to ensure that there is room for error in the illumination.
Refer to Beam Spot Profiles (Typical Examples) on page 5 for design information.
4
ZUV Series
Engineering Data (Reference Value)
Beam Spot Profiles (Typical Examples)
Standard head /ultra cooling head (Controller ZUV-C20H/C30H, at 100% irradiation power)
13000
WD=10
WD=12
WD=14
WD=16
WD=20
12000
11000
10000
9000
8000
Spot lens ZUV-L3H Illumination profile
Illumination (mW/cm2)
Illumination (mW/cm2)
Ultra light focus lens ZUV-L2H Illumination profile
9000
WD=8
WD=11
WD=13
WD=16
WD=20
8000
7000
6000
7000
5000
6000
4000
5000
3000
4000
3000
2000
2000
1000
1000
0
-5
-4
-3
-2
-1
0
1
2
0
-5
3
4
5
Position (mm)
WD=10
WD=14
WD=20
WD=25
WD=30
5000
4000
-3
-2
-1
0
1
2
3
4
5
Position (mm)
Spot lens ZUV-L6H Illumination profile
Illumination (mW/cm2)
Illumination (mW/cm2)
Spot lens ZUV-L4H Illumination profile
6000
-4
4500
WD=10
WD=15
WD=20
WD=25
WD=30
4000
3500
3000
2500
3000
2000
2000
1500
1000
1000
500
0
-5
-4
-3
-2
-1
0
1
2
0
-5
3
4
5
Position (mm)
WD=10
WD=15
WD=20
WD=25
WD=30
2000
-3
-2
-1
0
1
2
3
4
5
Position (mm)
Spot lens ZUV-L10H Illumination profile
Illumination (mW/cm2)
Illumination (mW/cm2)
Spot lens ZUV-L8H Illumination profile
2500
-4
1500
800
WD=10
WD=15
WD=20
WD=25
WD=30
WD=50
700
600
500
400
1000
300
200
500
100
-4
-3
-2
-1
0
1
2
0
-10
3
4
5
Position (mm)
-8
-6
-4
-2
0
2
4
6
8
10
Position (mm)
Side-view lens ZUV-L3S Illumination profile
Side-view lensZUV-L4S Illumination profile
8000
6000
WD=4
WD=5
WD=10
WD=15
WD=20
7000
6000
5000
Illumination (mW/cm2)
Illumination (mW/cm2)
0
-5
WD=4
WD=5
WD=10
WD=15
WD=20
5000
4000
3000
4000
3000
2000
2000
1000
1000
0
-5
-4
-3
-2
-1
0
1
2
3
4
5
Position (mm)
0
-5
-4
-3
-2
-1
0
1
2
3
4
5
Position (mm)
Note: 1. WD is setting distance to a workpiece from a lens unit end face.
Note: 2. The illumination profile varies depending on factors such as the ambient environment, installation conditions, the service life of part, and
differences between parts. Continually check the curing status of the resin to ensure that there is room for error in the illumination profile.
5
Side-view lens ZUV-L6S Illumination profile
Side-view lens ZUV-L8S Illumination profile
4000
2200
WD=5
WD=8
WD=10
WD=15
WD=20
3500
3000
2500
Illumination (mW/cm2)
Illumination (mW/cm2)
ZUV Series
WD=5
WD=10
WD=15
WD=18
WD=20
2000
1800
1600
1400
1200
2000
1000
1500
800
600
1000
400
500
0
-5
200
-4
-3
-2
-1
0
1
2
0
-5
3
4
5
Position (mm)
500
600
200
400
100
200
-4
-2
0
2
4
1400
WD=10
WD=15
WD=20
WD=30
1200
0
-10
6
8
10
Position (mm)
Line beam lens ZUV-L12L Illumination profile
(width direction)
1000
800
600
0
1
2
3
4
5
Position (mm)
WD=10
WD=15
WD=20
WD=30
1000
300
-6
-1
1200
800
-8
-2
1400
400
0
-10
Illumination (mW/cm2)
Illumination (mW/cm2)
600
-8
-6
-4
-2
0
2
4
6
8
10
Position (mm)
Diffuse illumination head ZUV-H25MC/H35MC
(Controller ZUV-C20H/C30H, at 100% irradiation)
Diffusing lens ZUV-L12H Illumination profile
Illumination (mW/cm2)
Illumination (mW/cm2)
WD=5
WD=10
WD=15
WD=20
WD=25
WD=30
WD=50
-3
Line beam lens ZUV-L12L Illumination profile
(length direction)
Side-view lens ZUV-L10S Illumination profile
700
-4
1000
WD=10
WD=15
WD=20
WD=25
WD=30
WD=50
900
800
700
600
500
400
400
200
0
-5
300
200
-4
-3
-2
-1
0
1
2
3
4
5
Position (mm)
100
0
-10
1200
WD=5
WD=10
WD=15
WD=20
WD=30
1000
800
400
200
200
-6
-3
0
3
6
9
12 15
Position (mm)
0
2
4
6
8
10
Position (mm)
WD=5
WD=10
WD=15
WD=20
WD=30
800
400
-9
-2
1000
600
-12
-4
1200
600
0
-15
-6
Line beam lens ZUV-L15L Illumination profile
(width direction)
Illumination (mW/cm2)
Illumination (mW/cm2)
Line beam lens ZUV-L15L Illumination profile
(length direction)
-8
0
-5
-4
-3
-2
-1
0
1
2
3
4
5
Position (mm)
Note: 1. WD is setting distance to a workpiece from a lens unit end face.
Note: 2. The illumination profile varies depending on factors such as the ambient environment, installation conditions, the service life of part, and
differences between parts. Continually check the curing status of the resin to ensure that there is room for error in the illumination profile.
6
ZUV Series
Safety Precautions
Refer to Warranty and Limitatious of Liability.
Controller
WARNING
Damage or fire may occur.
Do not exceed the rated voltage.
PRECAUTIONS FOR SAFE USE
Observe the following precautions to ensure safe operation.
1. Do not use the product in atmospheres containing flammable
or explosive gases.
2. Do not install the product close to high-voltage devices and/
or power devices in order to secure the safety of operations
and maintenance.
3. If you use an AC power supply, use the enclosed AC adapter
(100 to 240 VAC ± 10%).
4. If you use a DC power supply, do not use a power supply that
exceeds the rated voltage (24 VDC ± 10%). Also, do not
reverse the polarity when you connect the power supply.
Recommended power supply: OMRON S8VS-18024 (24 VDC,
7.5 A)
5. Do not short-circuit the load of an open-collector output.
6. Do not exceed the rated load.
7. Lay the product cable away from any high-voltage cable or
power line. If laid in the same conduit or duct, induction noise
from them may caused malfunction or breakdown of the
product.
8. In the event of smoke, excessive heat of the cover or strange
smell out of the product, immediately stop operation of the
product, turn OFF the power supply, and disconnect the plug
from the outlet. As repair by the customer is dangerous,
contact an OMRON's local office or sales office.
9. Do not try to disassemble, repair, or modify the product.
Doing so may result in malfunctions, causing fire or electric
shock.
10. Dispose this product as industrial waste.
11. Do not drop this product. In the event of dropping or breaking
the product, turn OFF the power supply, disconnect the
power plug from the outlet, and then contact an OMRON's
local office or sales office. Doing so may result in fire.
12. Do not put foreign material into a vent hole. Doing so may
result in fire or electric shock.
13. Do not closely contact or pile up controllers. Doing so may
result in fire or faults.
PRECAUTIONS FOR CORRECT USE
1. Avoid installing the product in the following places:
• Places exceeding the rated ambient temperature
• Places exposed to extreme temperature changes (prevent
condensation)
• Places where RH levels are outside the range 35% to 85%
• Places subject to corrosive or flammable gases
• Places subject to dust (including iron dust), or salts
• Places subject to direct shock or vibration
• Places subject to disturbance light such as ultraviolet (UV),
laser beam, welding arc
• Places subject to direct sunlight or places close to heaters
• Places subject to exposure to water, oil, or chemicals, or subject
to mist
• Places subject to strong magnetic field or electric field
2. Power supply and wiring
• When using the product, make sure FG (frame ground terminal)
is connected.
• If you use a DC power supply, ground the power supply.
• If you use a DC power supply, observe the following
precautions.
- If you use a commercially available switching regulator,
ground the FG terminal.
- If there is surge on the power line, connect a surge absorber
that is suitable for the application environment.
- Before you turn ON the power supply after wiring, confirm that
the power supply is wired correctly, make sure that the load is
not short-circuited, and make sure that the load current is
suitable.
• If you use the AC adapter, connect the power plug to the
Controller first and then plug the power cord into the outlet.
•When you disconnect the AC adapter, disconnect the power
cord from the outlet first and then disconnect it from the
Controller.
•When you connect or disconnect the Head Unit, make sure that
you do so with the power supply turned OFF.
•Use only the combinations of the Head Unit and Controller that
are given in this datasheet.
•You can use one of the special Extension Cables to extend the
cable length between a Head Unit and Controller, but you cannot
connect more than one Extension Cable together.
3. Cleaning
• Avoid the use of thinner, benzine, acetone, and kerosene. Use
of these solvents will melt the surface of the device.
• Use commercially available alcohol.
• Wipe out small dirt or dust carefully not to damage the lens
using a soft cloth (such as a lens cleaner) containing a small
quantity of alcohol.
4. Resin cure
State of resin cure changes depending on various factors.
Continuously check the state of resin cure to set at the best
condition.
5. Replacing the head
When you replace the Head Unit, always initialize the applicable
channel in the Controller. If you do not initialize the channel, the
previous Head Unit information (e.g., cumulative irradiation
energy and power tuning data) will remain and the new Head Unit
will not function correctly.
6. Connecting the head
If you disconnect a Head Unit and then reconnect it, always
connect it to the same channel. If you connect a Head Unit to a
different channel, the specific Head Unit information (e.g.,
cumulative irradiation energy and power tuning data) will not be
inherited and the Head Unit will not function correctly.
7. LED safety measures
As connected with the head, the unit generates UV that is
classified as Class 3B, so, this controller provides functions such
as safety key lock function. Use these functions according to
requirements specified in JIS C 6802.
Installing the controller
ZUV-C20H
80mm
Front
Rear
50mm
80mm
ZUV-C30H
80mm
Rear
Front
50mm
80mm
7
ZUV Series
Safety Precautions
Head Unit
WARNING
Direct exposure of eye or skin to ultraviolet light will
damage eyesight or the skin. Never look into or
expose the body to the ultraviolet light.
Work wearing protection glasses and protection
equipment if exposure to the reflected ultraviolet light is
considered.
5. Mounting of the head
Make sure to use attached mounting bracket for the head part.
Use the bracket within the specified mounting range. Misuse of
the mounting bracket may raise the temperature rise of the head
and shorten the usage life of LED.
Electric shock or leaked light may cause injury or
damage to the product.
Never disassemble the product.
CAUTION
Touching the product may result in burns.
Do not touch the product while energized or
immediately after turning OFF the power supply.
PRECAUTIONS FOR SAFE USE
Observe the following precautions to ensure safe operation.
1. Do not use the product in atmospheres containing flammable
or explosive gases.
2. Do not try to disassemble, repair, or modify this product.
3. Dispose of this product as industrial waste.
4. Do not touch the head lens for a long time during ultraviolet
light irradiation. Doing so may result in burns.
5. Do a special medical check-up, based on "Notice No.308" of
Ministry of Health, Labour and Welfare, for workers handling
this product.
6. Be sure to use the attached mounting bracket to fix the head
part. Use the bracket within the specified mounting range.
Misuse of the mounting bracket may raise the head
temperature, causing burns.
PRECAUTIONS FOR CORRECT USE
1. Avoid installing the product in the following places:
• Places exposed to strong electromagnetic fields
• Places where the lens in front of the head may be exposed to
dust, oil, or dew condensation.
• Places subject to corrosive gases
• Places where the product is exposed to direct shock or
vibration.
2. Wiring
• Keep the cable between the head and the controller away from
high-voltage cables or power lines. If laid in the same duct,
induction noise from them may cause malfunction or
breakdown of the product.
• Be sure to turn OFF the power supply when mounting or
demounting the head part.
• An extension cable can be used between head and the
controller. Do not use extended multiple cables.
3. Cleaning
• Avoid the use of thinner, benzine, acetone, and kerosene. Use of
these solvents will melt the surface of the product.
• Use commercially available alcohol.
• Wipe out small dirt or dust carefully not to damage the lens
using a soft cloth (such as a lens cleaner) containing a small
quantity of alcohol.
4. Resin cure
State of resin cure changes depending on various factors.
Continuously check the state of resin cure to set at the best
condition.
8
ZUV Series
Dimensions
(Unit: mm)
Controller
Value model ZUV-C20H
85
Multi-function model ZUV-C30H
2.5
146
Four, 14-dia. 24.5 23.6 15.45
head connector
85
105
Four, 14-dia. 21.5 30.8 13.1
9.7 head connector
10.1
146
106.6
30.8
80
37.4
21
3
15.7
18.6
18.6
61
18.6
6.1
57.4
31.6
2.5
6.6
18.6
12.6
56.6
125
30
27
36
81.6
28.4
55
125
3.5
85
4.1
12.7
49
6
12.7
12.7
12.7
26
Head Unit
Mounting Bracket
Standard head (When attached to spot lens)
Value model ZUV-H20MC
2000
54.6
11.1
12 dia.
Two, M4 x valid depth 6
20
ZUV-H30MC
300
54.6
11.1
43
12 dia.
43
13
14.7 dia.
14.7 dia.
5 dia.
12
.
dia 21.5
26
5 dia.
Lens unit
Lens unit
20
20
40
2
Ultra cooling head
ZUV-H10MC
300
126.6
43
11.1
12 dia.
14.7 dia.
5 dia.
Lens unit
Diffuse illumination head (When attached to ZUV-L12H)
Value model ZUV-H25MC
51.2
ZUV-H35MC
43
2000
51.2
7.7
12 dia.
43
300
7.7
12 dia.
14.7 dia.
14.7 dia.
5 dia.
5 dia.
Lens unit
Lens unit
Lens Unit
Spot lens ZUV-L3H/L4H/L6H/L8H/L10H
Ultra light focus lens ZUV-L2H
Note: The model number is printed on the side of the Lens unit.
11.1
4.4
3.5
12 dia.
19.1
2.6
12 dia.
11.1
1.7
62.6
ZUV-L3H/L4H/L6H/L8H
2000
43
19.1
ZUV-L10H
14.7 dia.
5 dia.
Line beam lens ZUV-L12L
15.1
1
12 dia.
58.6
15.1
Lens unit
ZUV-L15L
2000
54.5
11
43
Note: When attached to ZUV-H20MC
(Standard head value model)
11
12 dia.
1.5
2000
43
14.7 dia.
14.7 dia.
5 dia.
5 dia.
Lens unit
Lens unit
Note: When attached to ZUV-H25MC
(Diffuse illumination head value model)
Note: When attached to ZUV-H20MC
(Standard head value model)
Side-view lens ZUV-L_S
Diffusing lens ZUV-L12H
22.7
12 dia.
7
0.8
0.8
66.2
Note: The model number is
printed on the side of
the lens unit.
12 dia.
2000
51.2
43
7.7
12 dia.
43
2000
7.7
22.7
14.7 dia.
14.7 dia.
5 dia.
Lens unit
Note: When attached to ZUV-H20MC
(Standard head value model)
5 dia.
Lens unit
Note: When attached to ZUV-H25MC
(Diffuse illumination head value model)
9
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2016.2
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/