Non-Reversing Starters, Class 14

Heavy Duty Starters
Features and Benefits
General
NEMA starters are ideal for
applications requiring dependability
and durability. Typical applications
include use with machine tools, air
conditioning equipment, material
handling equipment, compressors,
hoists and various production and
industrial ­equipment as well as in
demanding automotive applications.
Starters are available as an open type
or in NEMA 1, 12/3/3R, 4 (painted), 4/4X
(stainless), 4X (fiberglass), and 7 & 9
enclosures.
Solid State Starter Class 14
Standard Features
CONTROL
PRODUCTS
17
NEMA & General
Purpose Control
Size 00–4 magnetic starters include the
following standard features:
b
b
b
b
Rugged Industrial Design
b
b
b
b
b
b
b
Wide Range of Accessories
Half Sizes for Cost and Space Savings
Dual Voltage, Dual Frequency Coils
Solid State or Ambient Compensated
Bimetal Overload Protection
Easy Coil Access
Overload Test Feature
Straight Thru Wiring
Gravity Dropout
Large Silver Cadmium Contacts
UL listed file #E14900 (class 14, 22,
30, 40 & 43)
b CSA certified file #LR 6535 (class 14,
22, 30, 40 & 43)
Application
Heavy Duty starters are designed for
across the line starting of single phase
and polyphase motors.
These controls are available in NEMA
Sizes 00 through 8. In addition to the
usual NEMA Starter Sizes, Siemens
offers three exclusive Half Sizes; 13⁄4,
21⁄2 and 31⁄2. These integral sizes offer
the same rugged, industrial
construction as our NEMA Sizes and
ensure efficient operating performance.
Half Sizes provide a real cost savings
by cutting down on over capacity when
NEMA Sizes exceed the motor ratings. All Siemens Heavy Duty controls,
including our popular Half Sizes comply
with applicable NEMA and UL tests.
All starters are supplied with a NO
holding interlock that in conjunction
with an appropriate pilot device will
provide low voltage protection or
release.
17-12
are available to meet particular
application requirements
b Normally opened or normally closed
auxiliary power pole kits are available
for Sizes 00 through 13⁄4
b Transformers can be ordered as
either factory or field modifications.
In some cases these may require a
larger enclosure
b A full line of replacement parts are
available including contact kits, coils,
and overload relays
Gravity Dropout
For added reliability, the gravity dropout
of the armature and contacts is assisted
by stainless steel springs which help
provide quick, precise opening of the
contacts.
Part No
49D70084
45 Degree, Wedge Action Contacts
The 45 degree, wedge action contacts
reduce tracking and provide faster arc
quenching. The resulting self-cleaning
and reduced contact bounce mean
cooler operation and longer life for the
large silver cadmium oxide contacts.
Terminal Design
Control terminals are self-rising
pressure type.
Molded Coil
Magnetic coils are carefully wound and
then sealed in epoxy. Encapsulation
helps seal out moisture, promotes
heat transfer and resists electrical,
mechanical and thermal stresses.
Dual Voltage/Frequency Coil
Starters are available with dual voltage,
dual frequency coils. They are designed
to operate on either 50 or 60 Hertz.
Molded Stationary Contact Block
Thermoset materials resist arc tracking
and the stresses of heat and severe
impact.
Field Modification Kits
All starters can be modified in the field
with a complete range of accessories.
These include pushbuttons, selector
switches, pilot lights, auxiliary contacts
and surge suppressors.
Auxiliary Equipment
b NEMA starters are available with
built-in START-STOP push ­buttons
for 3-wire control or a
HAND-OFF-AUTO selector
switch for 2-wire control
b Field modifications such as auxiliary
contacts, pilot lights, push buttons,
selector switches, and fuse blocks Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
Siemens Sizes 0­0–13⁄4 have as
standard, universal mounting which
fits the following:
Cutler Hammer—Citation Series
—Freedom Series
GE
—300 Line
Square D
—Type S
The Starter with its existing
backplate mounts onto the piggyback
mounting plate and is secured in
place with three mounting screws.
The piggyback mounting plate fits
the following:
Allen-Bradley
—Bulletin 509
—Bulletin 709
Westinghouse —Series A200
Size 5 & 6 Starters
Additional Features
b Solid State Overload (3RB type)
Standard
b Latest technology in arc quenching to
extend contactor life
b Wide variety of enclosures in all
starter configurations
Size 7 & 8 Starters
Additional Features
b New Compact Design
b Can be mounted in any position
b Same coil voltage is AC or DC
Heavy Duty Starters
Features and Benefits
Selection
Half Size Starters
Half-Size starters feature all the
rugged performance characteristics of
our NEMA rated starter sizes, but are
fractionally sized to more closely match
your exact motor rating. As a result,
significant economic savings are made
possible without sacrificing the reliability
you expect from a heavy duty starter.
ESP200™ Solid State Starter
ESP200™ starters combine the rugged
NEMA contactors with a state of the
art solid state overload that provides
phase loss, phase unbalance ground
fault protection. It offers the user
greater motor protection and extended
life in heavy duty applications. The
ESP200™ ultimately results in a cost
savings to the user.
Using the table below, simply match
the specific size starter to the
horsepower rating of your motor.
Every half-size starter saves you
money—up to 31%.
b
b
b
b
Set Phase Unbalance ON or OFF
Set Phase Loss ON or OFF
Set Reset to Manual or Automatic
Set Ground Fault ON or OFF
All “half-sizes” comply to applicable
NEMA and UL standards.
ESP200® FLA Adjustment Dial—Set the
adjustment dial on the overload to the FLA of the motor.
Figure 1
17
CONTROL
PRODUCTS
b True phase loss protection; trips
within 3 seconds
b Phase unbalanced prevents motor
running inefficiently
b Ground fault trip when selected
b Selectable trip class 5, 10, 20 or 30
b Reset trip can be selected Auto/
Manual restart
b Easy to select and use, Dip Switch
selectable
b Overload is self powered, no need for
external power source
Exclusive “half-sizes” save potentially
hundreds, even thousands of dollars
per project.
DIP Switch Settings
Adjust DIP switch settings to the Trip
Class desired 5, 10, 20, or 30.
NEMA & General
Purpose Control
ESP200™ Solid State Overload Relays
Standard features provide Improved
Starter Performance:
These additional starter sizes have the
reserve capacity to handle occasional
plugging and jogging applications
without derating. Superior operating
performance in heavy duty applications
is assured by the large current carrying
parts, not by derating the device.
Typical Solid-State Overload
Adjustment Dial Markings
Each overload is precisely calibrated
and labels are laser printed.
Savings for Siemens “Half-Size” Starters in NEMA 1 Enclosures, FVNR
Motor Size
230V
460V
Starter
Size
Half
Size
List Price $
“Half-Size”
Savings Over
Next Full Size
7 1⁄2
10
1
—
10
15
—
13⁄4
31%
15
25
2
—
—
20
30
—
2⁄
20%
Type
Size (3rd Character)
Configuration
30
50
3
—
—
B Thru E
1N.O.
Internal
F Thru J
1N.O.
External
L Thru M
2N.O., 2N.C.
External
N Thru P
1N.O., 1N.C.
External
1 2
—
Standard Auxiliary Contacts
40
75
—
31⁄2
13%
All FVNR
Starters &
Contactors
50
100
4
—
—
Product Category: NEMA
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
Internal / External
17-13
Heavy Duty Motor Starters
Solid State Overload with Auto/Manual Reset, Class 14
Selection
Ordering Information
Coil Table
R eplace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
 Field Modification Kits see page 17-93.
 Factory Modifications see page 17-108.
 Dimensions see pages 17-116 open and 17-129 enclosed.
 Wiring Diagrams see page 17-144.
 Replacement Parts see page 17-170.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240a
200–208
220–240
277
220–240/440–480a
440–480
575–600
Letter­
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 17-108.
Open Type & Standard Width Enclosure, 3-Phase, 3-Pole
­Max Hp
Overload
Enclosure
Open Type
CONTROL
PRODUCTS
17
NEMA & General
Purpose Control
Standard Auxiliary
Contactsg
200
Volts
1
⁄6
1
⁄2
11⁄2
1
⁄6
1
⁄2
2
3
1
⁄6
1
⁄2
2
3
71⁄2
10
10
15
25
30
40
75
150
—
—
230
Volts
1
⁄6
3
⁄4
11⁄2
1
⁄6
3
⁄4
2
3
1
⁄6
3
⁄4
2
3
71⁄2
10
15
20
30
40
50
100
200
300
450
460
Volts
1
⁄3
11⁄2
2
1
⁄3
11⁄2
5
—
1
⁄3
11⁄2
5
10
—
15
25
30
50
75
100
200
400
600
900
575
Volts
1
⁄2
2
—
1
⁄2
2
5
—
1
⁄2
2
5
10
—
15
25
30
50
75
100
200
400
600
900
NEMA Half Amp Size Size Range
00
— 0.25–1
00
— 0.75–3.4
00
— 3–12
0
— 0.25–1
0
— 0.75–3.4
0
— 3–12
0
— 5.5–22
1
— 0.25–1
1
— 0.75–3.4
1
— 3–12
1
— 5.5–22
1
— 10–40
—
13⁄4 10–40
2
— 13–52
—
21⁄2 25–100
3
— 25–100
—
31⁄2 50–200
4
— 50–200
5
— 55–250
6
— 160–630
7*e — 400–1220
— 400–1220
8f
Frame Catalog
Size Number
14BUA32A*
A
14BUB32A*
A
14BUC32A*
A1
14CUA32A*
A
14CUB32A*
A
14CUC32A*
A1
14CUD32A*
A1
14DUA32A*
A
14DUB32A*
A
14DUC32A*
A1
14DUD32A*
A1
14DUE32A*
A1
14EUE32A*
A1
14FUF32A*
B
14GUG32A*
B
14HUG32A*
B
14IUH32A*
B
14JUH32A*
B
14LPU32A*
—
14MPX32A*
—
A1+CT 14NUN32A*
A1+CT 14PUN32A*
List
Price $
NEMA 1
NEMA 4/4X Stainlessb NEMA 4X
Watertight, Dust-tight,
Fiberglass
General Purpose
Catalog
Number
14BUA32B*
14BUB32B*
14BUC32B*
14CUA32B*
14CUB32B*
14CUC32B*
14CUD32B*
14DUA32B*
14DUB32B*
14DUC32B*
14DUD32B*
14DUE32B*
14EUE32B*
14FUF32B*
14GUG32B*
14HUG32B*
14IUH32B*
14JUH32B*
14LPU32B*
14MPX32B*
14NUN32B*
14PUN32B*
List
Price $
NEMA 7 & 9
NEMA 3 & 4
NEMA 12
NEMA 3/3Rb
Catalog
Number
Use Size 0
Use Size 0
Use Size 0
14CUA320*
14CUB320*
14CUC320*
14CUD320*
14DUA320*
14DUB320*
14DUC320*
14DUD320*
14DUE320*
14EUE320*
14FUF320*
14GUG320*
14HUG320*
14IUH320*
14JUH320*
14LPU320*
14MPX320*
14NUN320*
14PUN320*
Corrosion Resistant 304 Stainless Steel
316 Stainless Steel
Optional)h
Watertight, Dust-tight
Corrosion Resistant
Div. 1 and Div. 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
Catalog
Number
Use Size 0
Use Size 0
Use Size 0
14CUA32W*
14CUB32W*
14CUC32W*
14CUD32W*
14DUA32W*
14DUB32W*
14DUC32W*
14DUD32W*
14DUE32W*
14EUE32W*
14FUF32W*
14GUG32W*
14HUG32W*
14IUH32W*
14JUH32W*
14LPU32E*d
14MPX32E*d
14NUN32E*d
14PUN32E*d
Catalog
Number
Use Size 0
Use Size 0
Use Size 0
14CUA32F*
14CUB32F*
14CUC32F*
14CUD32F*
14DUA32F*
14DUB32F*
14DUC32F*
14DUD32F*
14DUE32F*
14EUE32F*
14FUF32F*
14GUG32F*
14HUG32F*
14IUH32F*
14JUH32F*
—
—
—
—
Catalog
Number
Use Size 0
Use Size 0
Use Size 0
14CUA32H*
14CUB32H*
14CUC32H*
14CUD32H*
14DUA32H*
14DUB32H*
14DUC32H*
14DUD32H*
14DUE32H*
14EUE32H*
14FUF32H*
14GUG32H*
14HUG32H*
14IUH32H*
14JUH32H*
14LPU32H*
—
—
—
List
Price $
—
—
—
List
Price $
—
—
—
—
—
—
—
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
List
Price $
—
—
—
—
—
—
List
Price $
—
—
—
Open Type & Standard Width Enclosure, Single Phase, 2-Polec
Max Hp
Overload
Enclosure
Open Type
Standard Auxiliary
Contacts
115
Volts
1
⁄8
1
⁄4
1
1
⁄8
1
⁄4
1
208/
230
Volts
1
⁄4
1
⁄2
2
1
⁄4
1
⁄2
2
NEMA
Size
0
0
0
1
1
1
Amp
Range
0.75–3.4
3–12
5.5–22
0.75–3.4
3–12
5.5–22
Frame
Size
A
A1
A1
A
A1
A1
Catalog
Number
14CUB12A*
14CUC12A*
14CUD12A*
14DUB12A*
14DUC12A*
14DUD12A*
List
Price $
Note: A
ll starter sizes carry one maximum Hp rating (per the
National Electric Code).
a Dual voltage coils not available in size 5–8 starters.
­b For conduit hubs and conversion instructions, see
page 17-99.
17-14
NEMA 1
NEMA 4/4X Stainlessb NEMA 4X Fiberglass NEMA 7 & 9
Watertight, Dust-tight,
Watertight, Dust-tight
NEMA 3 & 4
General Purpose
Catalog
Number
14CUB12B*
14CUC12B*
14CUD12B*
14DUB12B*
14DUC12B*
14DUD12B*
List
Price $
Corrosion Resistant Corrosion Resistant
304 Stainless Steel
316 Stainless Steel (Optional)
Div. 1 and Div. 2 Class I
Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
Catalog
Number
14CUB12W*
14CUC12W*
14CUD12W*
14DUB12W*
14DUC12W*
14DUD12W*
Catalog
Number
14CUB12H*
14CUC12H*
14CUD12H*
14DUB12H*
14DUC12H*
14DUD12H*
c Coils
List
Price $
Catalog
Number
14CUB12F*
14CUC12F*
14CUD12F*
14DUB12F*
14DUC12F*
14DUD12F*
D, F, or G will be wired for incoming voltage. J coil
will be wired for separate source. Coils E, H, and L do
not apply to single phase starters.
d Enclosure is NEMA Type 4 (painted steel).
e F coil 100-250V AC 50/60Hz, or DC,
H coil 150-500V AC 50/60Hz, or DC
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
List
Price $
List
Price $
NEMA 12
NEMA 3/3Rb
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
Catalog
Number
14CUB120*
14CUC120*
14CUD120*
14DUB120*
14DUC120*
14DUD120*
List
Price $
f Only available F coil100-250V AC 50/60Hz, or DC
g Standard Auxiliary Contacts, Same as Contactors,
refer to page 17-13.
316 Stainless Steel option see page 17-111.
h For
Product Category: NEMA
Heavy Duty Motor Starters
Solid State Overload with Auto/Manual Reset, Class 14
Selection
Ordering Information
Coil Table
R eplace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
 Field Modification Kits see page 17-93.
 Factory Modifications see page 17-108.
 Dimensions see page 17-129.
 Wiring Diagrams see page 17-144.
 Replacement Parts see page 17-170.

NEMA 1
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter­
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 17-108.
Extra Wide Enclosure, 3-Phase, 3-Pole
Max Hp
Overload
Enclosure
NEMA 1
NEMA 4/4X Stainlessa
General Purpose
Frame Catalog
Number
Size
14BUA82B*
A
⁄2
NEMA 12
NEMA 3/3Ra
Div. 1 and Div. 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
Industrial Use
Weatherproof
(Field Convertible to 3/3R)
List
Price $
Catalog
Number
Use Size 0
List
Price $
—
Catalog
Number
Use Size 0
List
Price $
—
Catalog
Number
Use Size 0
List
Price $
—
1
3
⁄4
11⁄2
2
00
—
0.75–3.4
A
14BUB82B*
Use Size 0
—
Use Size 0
—
Use Size 0
—
11⁄2
11⁄2
2
—
00
—
3–12
A1
14BUC82B*
Use Size 0
—
Use Size 0
Use Size 0
⁄3
1
⁄2
0
—
0.25–1
A
14CUA82B*
14CUA82W*
14CUA82H*
14CUA820*
—
1
—
⁄6
1
1
⁄2
3
⁄4
11⁄2
2
0
—
0.75–3.4
A
14CUB82B*
14CUB82W*
14CUB82H*
14CUB820*
2
2
5
5
0
—
3–12
A1
14CUC82B*
14CUC82W*
14CUC82H*
14CUC820*
3
3
—
—
0
—
5.5–22
A1
14CUD82B*
14CUD82W*
14CUD82H*
14CUD820*
⁄6
1
1
⁄2
2
1
⁄3
1
⁄2
1
—
0.25–1
A
14DUA82B*
14DUA82W*
14DUA82H*
14DUA820*
3
⁄4
11⁄2
2
1
—
0.75–3.4
A
14DUB82B*
14DUB82W*
14DUB82H*
14DUB820*
2
5
5
1
—
3–12
A1
14DUC82B*
14DUC82W*
14DUC82H*
14DUC820*
3
3
10
10
1
—
5.5–22
A1
14DUD82B*
14DUD82W*
14DUD82H*
14DUD820*
71⁄2
71⁄2
—
—
1
—
10–40
A1
14DUE82B*
14DUE82W*
14DUE82H*
14DUE820*
10
10
15
15
—
13⁄4
10–40
A1
14EUE82B*
14EUE82W*
14EUE82H*
14EUE820*
10
15
25
25
2
—
13–52
B
14FUF82B*
14FUF82W*
14FUF82H*
14FUF820*
15
20
30
30
—
21⁄2
25–100
B
14GUG82B*
14GUG82W*
14GUG82H*
14GUG820*
25
30
50
50
3
—
25–100
B
14HUG82B*
14HUG82W*
14HUG82H*
14HUG820*
30
40
75
75
—
31⁄2
50–200
B
14IUH82B*
14IUH82W*
14IUH82H*
14IUH820*
Note: A
ll starter sizes carry one maximum Hp rating (per the
National Electric Code).­
a For
conduit hubs and conversion instructions, see
page 17-99.
b For
Product Category: NEMA
316 Stainless Steel option see page 17-111.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
17-15
CONTROL
PRODUCTS
⁄6
1
17
⁄6
1
NEMA & General
Purpose Control
200 230 460 575 NEMA Half Amp
Volts Volts Volts Volts Size
Size Range
1
1
1
1
⁄6
⁄6
⁄3
⁄2
00
—
0.25–1
NEMA 7 & 9
NEMA 3 & 4
Watertight, Dust-tight,
Corrosion Resistant 304 Stainless Steel
316 Stainless Steel (Optional)b
Heavy Duty Motor Starters
Ambient Compensated Bimetal Overload with Manual and Auto Reset, Class 14
Ordering Information
Selection
Coil Table
R eplace the (*) with a letter from the coil table. Dual voltage coils are
wired on high voltage unless specified on order.
 Heater elements see page 17-163. Single phase starters require 1 heater element. 3-phase starters require 3 heater elements.
 Field Modification Kits page 17-93.
 Factory Modifications page 17-108.
 Dimensions see page 17-116 open and 17-129 enclosed.
 Wiring Diagrams see page 17-144.
 Replacement Parts see page 17-170.

60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240
200–208
220–240
277
220–240/440–480
440–480
575–600
Letter
J
F
A
D
G
L
C
H
E
For other voltages and frequencies, see Factory Modifications page 17-108.
Open Type & Standard Width Enclosure, 3-Phase, 3-Pole
Max Hp
Enclosure
Open Type
NEMA 4/4X Stainlessb NEMA 4X Fiberglass NEMA 7 & 9
Watertight, Dust-tight
Watertight, Dust-tight NEMA 3 & 4
NEMA 1
Standard Auxiliary
Contactsd
General Purpose
Corrosion Resistant
Corrosion Resistant
304 Stainless Steele
NEMA 12
NEMA 3/3Rb
Industrial Use
Div 1 and Div 2
Class I Groups C & D Weatherproof
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
Cont-
actor
200
230
460
575
Amp NEMA Half
Volts Volts Volts Volts Rating Size
Size
Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $Catalog No Price $
NEMA & General
Purpose Control
1 1⁄2
3
7 1⁄2
10
10
15
25
30
40
17
2
5
10
15
25
30
50
75
100
2
5
10
15
25
30
50
75
100
9
18
27
40
45
60
90
115
135
—
—
—
13⁄4
—
21⁄2
—
31⁄2
—
00
0
1
—
2
—
3
—
4
14BP32A*81
14CP32A*81
14DP32A*81
14EP32A*81
14FP32A*81
14GP32A*81
14HP32A*81
14IP32A*81
14JG32A*81
14BP32B*81
14CP32B*81
14DP32B*81
14EP32B*81
14FP32B*81
14GP32B*81
14HP32B*81
14IP32B*81
14JG32B*81
Use Size 0 —
14CP32W*81
14DP32W*81
14EP32W*81
14FP32W*81
14GP32W*81
14HP32W*81
14IP32W*81
14JG32W*81
Use Size 0 —
Use Size 0 —
14CP32H*81
14CP32F*81
14DP32F*81
14DP32H*81
14EP32F*81
14EP32H*81
14FP32H*81
14FP32F*81
14GP32F*81
14GP32H*81
14HP32F*81
14HP32H*81
14IP32F*81
14IP32H*81
14JG32F*81
14JG32H*81
Use Size 0 —
14CP320*81
14DP320*81
14EP320*81
14FP320*81
14GP320*81
14HP320*81
14IP320*81
14JG320*81
Open Type & Standard Width Enclosure, Single Phase, 2-Polec
Max Hp
Enclosure
Open Type
CONTROL
PRODUCTS
1 1⁄2
3
7 1⁄2
10
15
20
30
40
50
NEMA 4/4X Stainlessb NEMA 4X Fiberglass NEMA 7 & 9
NEMA 3 & 4
NEMA 1
General Purpose
Watertight, Dust-tight
Watertight, Dust-tight
Corrosion Resistant
Corrosion Resistant
304 Stainless Steele
Contactor
NEMA 12
NEMA 3/3Rb
Div 1 and Div 2
Industrial Use
Class I Groups C & D Weatherproof
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
115
Volts
208/230
Volts
Amp
Rating
NEMA
Size
Half
Size
Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $Catalog No Price $
1⁄3
1
2
3
3
5
1
2
3
5
7 1⁄2
10
9
18
27
35
45
60
00
0
1
1P
2
—
—
—
—
—
—
21⁄2
14BP12A*81
14CP12A*81
14DP12A*81
14EP12A*81
14FP12A*81
14GP12A*81
14BP12B*81
14CP12B*81
14DP12B*81
14EP12B*81
14FP12B*81
14GP12B*81
Use Size 0
14CP12W*81
14DP12W*81
14EP12W*81
14FP12W*81
14GP12W*81
—
Use Size 0
14CP12F*81
14DP12F*81
14EP12F*81
14FP12F*81
14GP12F*81
—
Use Size 0
14CP12H*81
14DP12H*81
14EP12H*81
14FP12H*81
14GP12H*81
—
Use Size 0
—
14CP120*81
14DP120*81
14EP120*81
14FP120*81
14GP120*81
Extra Wide Enclosure, 3-Phase, 3-Polea
Max Hp
Enclosure
NEMA 1
200
Volts
1 1⁄2
3
7 1⁄2
10
10
15
25
30
40
230
460
575
Volts Volts Volts
1 1⁄2
2
2
3
5
5
7 1⁄2
10
10
10
15
15
15
25
25
20
30
30
30
50
50
40
75
75
50
100
100
NEMA 4/4X Stainlessb
Watertight, Dust-tight
Corrosion Resistant
304 Stainless Steele
Contactor
Amp
NEMA Half
Rating
Size Size Catalog No
List Price $
Catalog No
List Price $
9
00
— 14BP82B*81
Use Size 0 — 18
0
— 14CP82B*81
14CP82W*81
27
1
— 14DP82B*81
14DP82W*81
3
40
—
1 ⁄4 14EP82B*81
14EP82W*81
45
2
— 14FP82B*81
14FP82W*81
1
60
—
2 ⁄2 14GP82B*81
14GP82W*81
90
3
— 14HP82B*81
14HP82W*81
115
—
3 1⁄2 14IP82B*81
14IP82W*81
135
4
— 14JG82B*81
14JG82W*81
Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All Starter Sizes carry
one maximum Hp rating. For higher Hp single
phase motors, use 3-phase starters, wire and set
per diagram on page 17-144.
17-16
General Purpose
a To
receive a single phase starter in an extra wide
enclosure, order the enclosure kit from pg 16-91 and
the open style starter from pg 16-14 or 16-16 as
separate items.
b For conduit hubs and conversion instructions, see
page 17-99.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
NEMA 7 & 9
NEMA 3 & 4
NEMA 12
NEMA 3/3Rb
Catalog No
List Price $
Use Size 0 — 14CP82H*81
14DP82H*81
14EP82H*81
14FP82H*81
14GP82H*81
14HP82H*81
14IP82H*81
14JG82H*81
Catalog No
Use Size 0
14CP820*81
14DP820*81
14EP820*81
14FP820*81
14GP820*81
14HP820*81
14IP820*81
14JG820*81
Div 1 and Div 2
Class II Groups E, F & G
Class III
Bolted Enclosures
Indoor/Outdoor Use
Industrial Use
Weatherproof
List Price $
—
c Coils
D, F, or G will be wired for incoming voltage.
J coil will be wired for separate source. Coils E, H,
and L do not apply to single phase starters.
d Standard Auxiliary Contacts, Same as Contactors,
refer to page 17-44.
e For 316 Stainless Steel option see page 17-111.
Product Category: NEMA