Heavy Duty Starters Features and Benefits General NEMA starters are ideal for applications requiring dependability and durability. Typical applications include use with machine tools, air conditioning equipment, material handling equipment, compressors, hoists and various production and industrial equipment as well as in demanding automotive applications. Starters are available as an open type or in NEMA 1, 12/3/3R, 4 (painted), 4/4X (stainless), 4X (fiberglass), and 7 & 9 enclosures. Solid State Starter Class 14 Standard Features CONTROL PRODUCTS 17 NEMA & General Purpose Control Size 00–4 magnetic starters include the following standard features: b b b b Rugged Industrial Design b b b b b b b Wide Range of Accessories Half Sizes for Cost and Space Savings Dual Voltage, Dual Frequency Coils Solid State or Ambient Compensated Bimetal Overload Protection Easy Coil Access Overload Test Feature Straight Thru Wiring Gravity Dropout Large Silver Cadmium Contacts UL listed file #E14900 (class 14, 22, 30, 40 & 43) b CSA certified file #LR 6535 (class 14, 22, 30, 40 & 43) Application Heavy Duty starters are designed for across the line starting of single phase and polyphase motors. These controls are available in NEMA Sizes 00 through 8. In addition to the usual NEMA Starter Sizes, Siemens offers three exclusive Half Sizes; 13⁄4, 21⁄2 and 31⁄2. These integral sizes offer the same rugged, industrial construction as our NEMA Sizes and ensure efficient operating performance. Half Sizes provide a real cost savings by cutting down on over capacity when NEMA Sizes exceed the motor ratings. All Siemens Heavy Duty controls, including our popular Half Sizes comply with applicable NEMA and UL tests. All starters are supplied with a NO holding interlock that in conjunction with an appropriate pilot device will provide low voltage protection or release. 17-12 are available to meet particular application requirements b Normally opened or normally closed auxiliary power pole kits are available for Sizes 00 through 13⁄4 b Transformers can be ordered as either factory or field modifications. In some cases these may require a larger enclosure b A full line of replacement parts are available including contact kits, coils, and overload relays Gravity Dropout For added reliability, the gravity dropout of the armature and contacts is assisted by stainless steel springs which help provide quick, precise opening of the contacts. Part No 49D70084 45 Degree, Wedge Action Contacts The 45 degree, wedge action contacts reduce tracking and provide faster arc quenching. The resulting self-cleaning and reduced contact bounce mean cooler operation and longer life for the large silver cadmium oxide contacts. Terminal Design Control terminals are self-rising pressure type. Molded Coil Magnetic coils are carefully wound and then sealed in epoxy. Encapsulation helps seal out moisture, promotes heat transfer and resists electrical, mechanical and thermal stresses. Dual Voltage/Frequency Coil Starters are available with dual voltage, dual frequency coils. They are designed to operate on either 50 or 60 Hertz. Molded Stationary Contact Block Thermoset materials resist arc tracking and the stresses of heat and severe impact. Field Modification Kits All starters can be modified in the field with a complete range of accessories. These include pushbuttons, selector switches, pilot lights, auxiliary contacts and surge suppressors. Auxiliary Equipment b NEMA starters are available with built-in START-STOP push buttons for 3-wire control or a HAND-OFF-AUTO selector switch for 2-wire control b Field modifications such as auxiliary contacts, pilot lights, push buttons, selector switches, and fuse blocks Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Siemens Sizes 00–13⁄4 have as standard, universal mounting which fits the following: Cutler Hammer—Citation Series —Freedom Series GE —300 Line Square D —Type S The Starter with its existing backplate mounts onto the piggyback mounting plate and is secured in place with three mounting screws. The piggyback mounting plate fits the following: Allen-Bradley —Bulletin 509 —Bulletin 709 Westinghouse —Series A200 Size 5 & 6 Starters Additional Features b Solid State Overload (3RB type) Standard b Latest technology in arc quenching to extend contactor life b Wide variety of enclosures in all starter configurations Size 7 & 8 Starters Additional Features b New Compact Design b Can be mounted in any position b Same coil voltage is AC or DC Heavy Duty Starters Features and Benefits Selection Half Size Starters Half-Size starters feature all the rugged performance characteristics of our NEMA rated starter sizes, but are fractionally sized to more closely match your exact motor rating. As a result, significant economic savings are made possible without sacrificing the reliability you expect from a heavy duty starter. ESP200™ Solid State Starter ESP200™ starters combine the rugged NEMA contactors with a state of the art solid state overload that provides phase loss, phase unbalance ground fault protection. It offers the user greater motor protection and extended life in heavy duty applications. The ESP200™ ultimately results in a cost savings to the user. Using the table below, simply match the specific size starter to the horsepower rating of your motor. Every half-size starter saves you money—up to 31%. b b b b Set Phase Unbalance ON or OFF Set Phase Loss ON or OFF Set Reset to Manual or Automatic Set Ground Fault ON or OFF All “half-sizes” comply to applicable NEMA and UL standards. ESP200® FLA Adjustment Dial—Set the adjustment dial on the overload to the FLA of the motor. Figure 1 17 CONTROL PRODUCTS b True phase loss protection; trips within 3 seconds b Phase unbalanced prevents motor running inefficiently b Ground fault trip when selected b Selectable trip class 5, 10, 20 or 30 b Reset trip can be selected Auto/ Manual restart b Easy to select and use, Dip Switch selectable b Overload is self powered, no need for external power source Exclusive “half-sizes” save potentially hundreds, even thousands of dollars per project. DIP Switch Settings Adjust DIP switch settings to the Trip Class desired 5, 10, 20, or 30. NEMA & General Purpose Control ESP200™ Solid State Overload Relays Standard features provide Improved Starter Performance: These additional starter sizes have the reserve capacity to handle occasional plugging and jogging applications without derating. Superior operating performance in heavy duty applications is assured by the large current carrying parts, not by derating the device. Typical Solid-State Overload Adjustment Dial Markings Each overload is precisely calibrated and labels are laser printed. Savings for Siemens “Half-Size” Starters in NEMA 1 Enclosures, FVNR Motor Size 230V 460V Starter Size Half Size List Price $ “Half-Size” Savings Over Next Full Size 7 1⁄2 10 1 — 10 15 — 13⁄4 31% 15 25 2 — — 20 30 — 2⁄ 20% Type Size (3rd Character) Configuration 30 50 3 — — B Thru E 1N.O. Internal F Thru J 1N.O. External L Thru M 2N.O., 2N.C. External N Thru P 1N.O., 1N.C. External 1 2 — Standard Auxiliary Contacts 40 75 — 31⁄2 13% All FVNR Starters & Contactors 50 100 4 — — Product Category: NEMA Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog Internal / External 17-13 Heavy Duty Motor Starters Solid State Overload with Auto/Manual Reset, Class 14 Selection Ordering Information Coil Table R eplace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Field Modification Kits see page 17-93. Factory Modifications see page 17-108. Dimensions see pages 17-116 open and 17-129 enclosed. Wiring Diagrams see page 17-144. Replacement Parts see page 17-170. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240a 200–208 220–240 277 220–240/440–480a 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 17-108. Open Type & Standard Width Enclosure, 3-Phase, 3-Pole Max Hp Overload Enclosure Open Type CONTROL PRODUCTS 17 NEMA & General Purpose Control Standard Auxiliary Contactsg 200 Volts 1 ⁄6 1 ⁄2 11⁄2 1 ⁄6 1 ⁄2 2 3 1 ⁄6 1 ⁄2 2 3 71⁄2 10 10 15 25 30 40 75 150 — — 230 Volts 1 ⁄6 3 ⁄4 11⁄2 1 ⁄6 3 ⁄4 2 3 1 ⁄6 3 ⁄4 2 3 71⁄2 10 15 20 30 40 50 100 200 300 450 460 Volts 1 ⁄3 11⁄2 2 1 ⁄3 11⁄2 5 — 1 ⁄3 11⁄2 5 10 — 15 25 30 50 75 100 200 400 600 900 575 Volts 1 ⁄2 2 — 1 ⁄2 2 5 — 1 ⁄2 2 5 10 — 15 25 30 50 75 100 200 400 600 900 NEMA Half Amp Size Size Range 00 — 0.25–1 00 — 0.75–3.4 00 — 3–12 0 — 0.25–1 0 — 0.75–3.4 0 — 3–12 0 — 5.5–22 1 — 0.25–1 1 — 0.75–3.4 1 — 3–12 1 — 5.5–22 1 — 10–40 — 13⁄4 10–40 2 — 13–52 — 21⁄2 25–100 3 — 25–100 — 31⁄2 50–200 4 — 50–200 5 — 55–250 6 — 160–630 7*e — 400–1220 — 400–1220 8f Frame Catalog Size Number 14BUA32A* A 14BUB32A* A 14BUC32A* A1 14CUA32A* A 14CUB32A* A 14CUC32A* A1 14CUD32A* A1 14DUA32A* A 14DUB32A* A 14DUC32A* A1 14DUD32A* A1 14DUE32A* A1 14EUE32A* A1 14FUF32A* B 14GUG32A* B 14HUG32A* B 14IUH32A* B 14JUH32A* B 14LPU32A* — 14MPX32A* — A1+CT 14NUN32A* A1+CT 14PUN32A* List Price $ NEMA 1 NEMA 4/4X Stainlessb NEMA 4X Watertight, Dust-tight, Fiberglass General Purpose Catalog Number 14BUA32B* 14BUB32B* 14BUC32B* 14CUA32B* 14CUB32B* 14CUC32B* 14CUD32B* 14DUA32B* 14DUB32B* 14DUC32B* 14DUD32B* 14DUE32B* 14EUE32B* 14FUF32B* 14GUG32B* 14HUG32B* 14IUH32B* 14JUH32B* 14LPU32B* 14MPX32B* 14NUN32B* 14PUN32B* List Price $ NEMA 7 & 9 NEMA 3 & 4 NEMA 12 NEMA 3/3Rb Catalog Number Use Size 0 Use Size 0 Use Size 0 14CUA320* 14CUB320* 14CUC320* 14CUD320* 14DUA320* 14DUB320* 14DUC320* 14DUD320* 14DUE320* 14EUE320* 14FUF320* 14GUG320* 14HUG320* 14IUH320* 14JUH320* 14LPU320* 14MPX320* 14NUN320* 14PUN320* Corrosion Resistant 304 Stainless Steel 316 Stainless Steel Optional)h Watertight, Dust-tight Corrosion Resistant Div. 1 and Div. 2 Class I Groups C & D Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use Catalog Number Use Size 0 Use Size 0 Use Size 0 14CUA32W* 14CUB32W* 14CUC32W* 14CUD32W* 14DUA32W* 14DUB32W* 14DUC32W* 14DUD32W* 14DUE32W* 14EUE32W* 14FUF32W* 14GUG32W* 14HUG32W* 14IUH32W* 14JUH32W* 14LPU32E*d 14MPX32E*d 14NUN32E*d 14PUN32E*d Catalog Number Use Size 0 Use Size 0 Use Size 0 14CUA32F* 14CUB32F* 14CUC32F* 14CUD32F* 14DUA32F* 14DUB32F* 14DUC32F* 14DUD32F* 14DUE32F* 14EUE32F* 14FUF32F* 14GUG32F* 14HUG32F* 14IUH32F* 14JUH32F* — — — — Catalog Number Use Size 0 Use Size 0 Use Size 0 14CUA32H* 14CUB32H* 14CUC32H* 14CUD32H* 14DUA32H* 14DUB32H* 14DUC32H* 14DUD32H* 14DUE32H* 14EUE32H* 14FUF32H* 14GUG32H* 14HUG32H* 14IUH32H* 14JUH32H* 14LPU32H* — — — List Price $ — — — List Price $ — — — — — — — Industrial Use Weatherproof (Field Convertible to 3/3R) List Price $ — — — — — — List Price $ — — — Open Type & Standard Width Enclosure, Single Phase, 2-Polec Max Hp Overload Enclosure Open Type Standard Auxiliary Contacts 115 Volts 1 ⁄8 1 ⁄4 1 1 ⁄8 1 ⁄4 1 208/ 230 Volts 1 ⁄4 1 ⁄2 2 1 ⁄4 1 ⁄2 2 NEMA Size 0 0 0 1 1 1 Amp Range 0.75–3.4 3–12 5.5–22 0.75–3.4 3–12 5.5–22 Frame Size A A1 A1 A A1 A1 Catalog Number 14CUB12A* 14CUC12A* 14CUD12A* 14DUB12A* 14DUC12A* 14DUD12A* List Price $ Note: A ll starter sizes carry one maximum Hp rating (per the National Electric Code). a Dual voltage coils not available in size 5–8 starters. b For conduit hubs and conversion instructions, see page 17-99. 17-14 NEMA 1 NEMA 4/4X Stainlessb NEMA 4X Fiberglass NEMA 7 & 9 Watertight, Dust-tight, Watertight, Dust-tight NEMA 3 & 4 General Purpose Catalog Number 14CUB12B* 14CUC12B* 14CUD12B* 14DUB12B* 14DUC12B* 14DUD12B* List Price $ Corrosion Resistant Corrosion Resistant 304 Stainless Steel 316 Stainless Steel (Optional) Div. 1 and Div. 2 Class I Groups C & D Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use Catalog Number 14CUB12W* 14CUC12W* 14CUD12W* 14DUB12W* 14DUC12W* 14DUD12W* Catalog Number 14CUB12H* 14CUC12H* 14CUD12H* 14DUB12H* 14DUC12H* 14DUD12H* c Coils List Price $ Catalog Number 14CUB12F* 14CUC12F* 14CUD12F* 14DUB12F* 14DUC12F* 14DUD12F* D, F, or G will be wired for incoming voltage. J coil will be wired for separate source. Coils E, H, and L do not apply to single phase starters. d Enclosure is NEMA Type 4 (painted steel). e F coil 100-250V AC 50/60Hz, or DC, H coil 150-500V AC 50/60Hz, or DC Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog List Price $ List Price $ NEMA 12 NEMA 3/3Rb Industrial Use Weatherproof (Field Convertible to 3/3R) Catalog Number 14CUB120* 14CUC120* 14CUD120* 14DUB120* 14DUC120* 14DUD120* List Price $ f Only available F coil100-250V AC 50/60Hz, or DC g Standard Auxiliary Contacts, Same as Contactors, refer to page 17-13. 316 Stainless Steel option see page 17-111. h For Product Category: NEMA Heavy Duty Motor Starters Solid State Overload with Auto/Manual Reset, Class 14 Selection Ordering Information Coil Table R eplace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Field Modification Kits see page 17-93. Factory Modifications see page 17-108. Dimensions see page 17-129. Wiring Diagrams see page 17-144. Replacement Parts see page 17-170. NEMA 1 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 17-108. Extra Wide Enclosure, 3-Phase, 3-Pole Max Hp Overload Enclosure NEMA 1 NEMA 4/4X Stainlessa General Purpose Frame Catalog Number Size 14BUA82B* A ⁄2 NEMA 12 NEMA 3/3Ra Div. 1 and Div. 2 Class I Groups C & D Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use Industrial Use Weatherproof (Field Convertible to 3/3R) List Price $ Catalog Number Use Size 0 List Price $ — Catalog Number Use Size 0 List Price $ — Catalog Number Use Size 0 List Price $ — 1 3 ⁄4 11⁄2 2 00 — 0.75–3.4 A 14BUB82B* Use Size 0 — Use Size 0 — Use Size 0 — 11⁄2 11⁄2 2 — 00 — 3–12 A1 14BUC82B* Use Size 0 — Use Size 0 Use Size 0 ⁄3 1 ⁄2 0 — 0.25–1 A 14CUA82B* 14CUA82W* 14CUA82H* 14CUA820* — 1 — ⁄6 1 1 ⁄2 3 ⁄4 11⁄2 2 0 — 0.75–3.4 A 14CUB82B* 14CUB82W* 14CUB82H* 14CUB820* 2 2 5 5 0 — 3–12 A1 14CUC82B* 14CUC82W* 14CUC82H* 14CUC820* 3 3 — — 0 — 5.5–22 A1 14CUD82B* 14CUD82W* 14CUD82H* 14CUD820* ⁄6 1 1 ⁄2 2 1 ⁄3 1 ⁄2 1 — 0.25–1 A 14DUA82B* 14DUA82W* 14DUA82H* 14DUA820* 3 ⁄4 11⁄2 2 1 — 0.75–3.4 A 14DUB82B* 14DUB82W* 14DUB82H* 14DUB820* 2 5 5 1 — 3–12 A1 14DUC82B* 14DUC82W* 14DUC82H* 14DUC820* 3 3 10 10 1 — 5.5–22 A1 14DUD82B* 14DUD82W* 14DUD82H* 14DUD820* 71⁄2 71⁄2 — — 1 — 10–40 A1 14DUE82B* 14DUE82W* 14DUE82H* 14DUE820* 10 10 15 15 — 13⁄4 10–40 A1 14EUE82B* 14EUE82W* 14EUE82H* 14EUE820* 10 15 25 25 2 — 13–52 B 14FUF82B* 14FUF82W* 14FUF82H* 14FUF820* 15 20 30 30 — 21⁄2 25–100 B 14GUG82B* 14GUG82W* 14GUG82H* 14GUG820* 25 30 50 50 3 — 25–100 B 14HUG82B* 14HUG82W* 14HUG82H* 14HUG820* 30 40 75 75 — 31⁄2 50–200 B 14IUH82B* 14IUH82W* 14IUH82H* 14IUH820* Note: A ll starter sizes carry one maximum Hp rating (per the National Electric Code). a For conduit hubs and conversion instructions, see page 17-99. b For Product Category: NEMA 316 Stainless Steel option see page 17-111. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-15 CONTROL PRODUCTS ⁄6 1 17 ⁄6 1 NEMA & General Purpose Control 200 230 460 575 NEMA Half Amp Volts Volts Volts Volts Size Size Range 1 1 1 1 ⁄6 ⁄6 ⁄3 ⁄2 00 — 0.25–1 NEMA 7 & 9 NEMA 3 & 4 Watertight, Dust-tight, Corrosion Resistant 304 Stainless Steel 316 Stainless Steel (Optional)b Heavy Duty Motor Starters Ambient Compensated Bimetal Overload with Manual and Auto Reset, Class 14 Ordering Information Selection Coil Table R eplace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Heater elements see page 17-163. Single phase starters require 1 heater element. 3-phase starters require 3 heater elements. Field Modification Kits page 17-93. Factory Modifications page 17-108. Dimensions see page 17-116 open and 17-129 enclosed. Wiring Diagrams see page 17-144. Replacement Parts see page 17-170. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 17-108. Open Type & Standard Width Enclosure, 3-Phase, 3-Pole Max Hp Enclosure Open Type NEMA 4/4X Stainlessb NEMA 4X Fiberglass NEMA 7 & 9 Watertight, Dust-tight Watertight, Dust-tight NEMA 3 & 4 NEMA 1 Standard Auxiliary Contactsd General Purpose Corrosion Resistant Corrosion Resistant 304 Stainless Steele NEMA 12 NEMA 3/3Rb Industrial Use Div 1 and Div 2 Class I Groups C & D Weatherproof Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use Cont- actor 200 230 460 575 Amp NEMA Half Volts Volts Volts Volts Rating Size Size Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $Catalog No Price $ NEMA & General Purpose Control 1 1⁄2 3 7 1⁄2 10 10 15 25 30 40 17 2 5 10 15 25 30 50 75 100 2 5 10 15 25 30 50 75 100 9 18 27 40 45 60 90 115 135 — — — 13⁄4 — 21⁄2 — 31⁄2 — 00 0 1 — 2 — 3 — 4 14BP32A*81 14CP32A*81 14DP32A*81 14EP32A*81 14FP32A*81 14GP32A*81 14HP32A*81 14IP32A*81 14JG32A*81 14BP32B*81 14CP32B*81 14DP32B*81 14EP32B*81 14FP32B*81 14GP32B*81 14HP32B*81 14IP32B*81 14JG32B*81 Use Size 0 — 14CP32W*81 14DP32W*81 14EP32W*81 14FP32W*81 14GP32W*81 14HP32W*81 14IP32W*81 14JG32W*81 Use Size 0 — Use Size 0 — 14CP32H*81 14CP32F*81 14DP32F*81 14DP32H*81 14EP32F*81 14EP32H*81 14FP32H*81 14FP32F*81 14GP32F*81 14GP32H*81 14HP32F*81 14HP32H*81 14IP32F*81 14IP32H*81 14JG32F*81 14JG32H*81 Use Size 0 — 14CP320*81 14DP320*81 14EP320*81 14FP320*81 14GP320*81 14HP320*81 14IP320*81 14JG320*81 Open Type & Standard Width Enclosure, Single Phase, 2-Polec Max Hp Enclosure Open Type CONTROL PRODUCTS 1 1⁄2 3 7 1⁄2 10 15 20 30 40 50 NEMA 4/4X Stainlessb NEMA 4X Fiberglass NEMA 7 & 9 NEMA 3 & 4 NEMA 1 General Purpose Watertight, Dust-tight Watertight, Dust-tight Corrosion Resistant Corrosion Resistant 304 Stainless Steele Contactor NEMA 12 NEMA 3/3Rb Div 1 and Div 2 Industrial Use Class I Groups C & D Weatherproof Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use 115 Volts 208/230 Volts Amp Rating NEMA Size Half Size Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $ Catalog No Price $Catalog No Price $ 1⁄3 1 2 3 3 5 1 2 3 5 7 1⁄2 10 9 18 27 35 45 60 00 0 1 1P 2 — — — — — — 21⁄2 14BP12A*81 14CP12A*81 14DP12A*81 14EP12A*81 14FP12A*81 14GP12A*81 14BP12B*81 14CP12B*81 14DP12B*81 14EP12B*81 14FP12B*81 14GP12B*81 Use Size 0 14CP12W*81 14DP12W*81 14EP12W*81 14FP12W*81 14GP12W*81 — Use Size 0 14CP12F*81 14DP12F*81 14EP12F*81 14FP12F*81 14GP12F*81 — Use Size 0 14CP12H*81 14DP12H*81 14EP12H*81 14FP12H*81 14GP12H*81 — Use Size 0 — 14CP120*81 14DP120*81 14EP120*81 14FP120*81 14GP120*81 Extra Wide Enclosure, 3-Phase, 3-Polea Max Hp Enclosure NEMA 1 200 Volts 1 1⁄2 3 7 1⁄2 10 10 15 25 30 40 230 460 575 Volts Volts Volts 1 1⁄2 2 2 3 5 5 7 1⁄2 10 10 10 15 15 15 25 25 20 30 30 30 50 50 40 75 75 50 100 100 NEMA 4/4X Stainlessb Watertight, Dust-tight Corrosion Resistant 304 Stainless Steele Contactor Amp NEMA Half Rating Size Size Catalog No List Price $ Catalog No List Price $ 9 00 — 14BP82B*81 Use Size 0 — 18 0 — 14CP82B*81 14CP82W*81 27 1 — 14DP82B*81 14DP82W*81 3 40 — 1 ⁄4 14EP82B*81 14EP82W*81 45 2 — 14FP82B*81 14FP82W*81 1 60 — 2 ⁄2 14GP82B*81 14GP82W*81 90 3 — 14HP82B*81 14HP82W*81 115 — 3 1⁄2 14IP82B*81 14IP82W*81 135 4 — 14JG82B*81 14JG82W*81 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All Starter Sizes carry one maximum Hp rating. For higher Hp single phase motors, use 3-phase starters, wire and set per diagram on page 17-144. 17-16 General Purpose a To receive a single phase starter in an extra wide enclosure, order the enclosure kit from pg 16-91 and the open style starter from pg 16-14 or 16-16 as separate items. b For conduit hubs and conversion instructions, see page 17-99. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog NEMA 7 & 9 NEMA 3 & 4 NEMA 12 NEMA 3/3Rb Catalog No List Price $ Use Size 0 — 14CP82H*81 14DP82H*81 14EP82H*81 14FP82H*81 14GP82H*81 14HP82H*81 14IP82H*81 14JG82H*81 Catalog No Use Size 0 14CP820*81 14DP820*81 14EP820*81 14FP820*81 14GP820*81 14HP820*81 14IP820*81 14JG820*81 Div 1 and Div 2 Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use Industrial Use Weatherproof List Price $ — c Coils D, F, or G will be wired for incoming voltage. J coil will be wired for separate source. Coils E, H, and L do not apply to single phase starters. d Standard Auxiliary Contacts, Same as Contactors, refer to page 17-44. e For 316 Stainless Steel option see page 17-111. Product Category: NEMA