Heavy Duty Contactors Single Phase, 4-Pole & Vacuum, Class 40 Selection Ordering Information Coil Table R eplace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Field Modification Kits see page 17-93. Factory Modifications see page 17-108. Dimensions see pages 17-120 open and 17-129 enclosed. Wiring Diagrams see page 17-155. Replacement Parts see page 17-170. 60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240a 200–208 220–240 277 220–240/440–480a 440–480 575–600 Letter J F A D G L C H E For other voltages and frequencies, see Factory Modifications page 17-108. Open Type & Standard Width Enclosure, Single Phase, 2-Pole cd Max Hp Enclosure Open Typee NEMA 1 NEMA 4/4X Stainlessb General Purposes NEMA 4X Fiberglass Watertight, Dust-tight Watertight, Dust-tight Corrosion Resistant Corrosion Resistant 304 Stainless Steel Cont- 208/ actor NEMA 7 & 9 NEMA 3 & 4 Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G Class III Bolted Enclosure Indoor/Outdoor Use NEMA 12 NEMA 3/3R b Industrial Use Weatherproof 115 230 Amp NEMA Half Volts Volts Rating Size Size Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ 1 2 3 5 7 1⁄2 10 15 — — 9 18 27 35 45 60 90 115 135 00 0 1 1P 2 — 3 — 4 40BP12A* 40CP12A* 40DP12A* 40EP12A* 40FP12A* 40GP12A* 40HP12A* 40IP12A* 40JG12A* — — — — — 21⁄2 — 31⁄2 — 40BP12B* 40CP12B* 40DP12B* 40EP12B* 40FP12B* 40GP12B* 40HP12B* 40IP12B* 40JG12B* Use Size 0 40CP12W* 40DP12W* 40EP12W* 40FP12W* 40GP12W* 40HP12W* 40IP12W* 40JG12W* — Use Size 0 40CP12F* 40DP12F* 40EP12F* 40FP12F* 40GP12F* 40HP12F* 40IP12F* 40JG12F* — Use Size 0 40CP12H* 40DP12H* 40EP12H* 40FP12H* 40GP12H* 40HP12H* 40IP12H* 40JG12H* — Use Size 0 40CP120* 40DP120* 40EP120* 40FP120* 40GP120* 40HP120* 40IP120* 40JG120* — NEMA & General Purpose Control 1⁄3 1 2 3 3 5 7 1⁄3 — — Open Type & Standard Width Enclosure, 4-Pole Enclosure Open Type NEMA 1 NEMA 4/4X Stainless b NEMA 4X NEMA 7 & 9 NEMA 3 & 4 NEMA 12 NEMA 3/3R b Div 1 and Div 2 Industrial Use Class I Groups C & D Weatherproof Class II Groups E, F & G Class III Bolted Enclosure Indoor/Outdoor Use 200 230 460 575 Amp NEMA Half Volts Volts Volts Volts Rating Size Size Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog NoList Price $ ⁄3 2 3 5 1 1 1⁄2 3 7 1⁄2 10 2 5 10 15 2 5 10 15 9 18 27 40 00 0 1 — — — — 13⁄4 40BP22A* 40CP22A* 40DP22A* 40EP22A* 40BP22B* 40CP22B* 40DP22B* 40EP22B* Use Size 0 40CP22W* 40DP22W* 40EP22W* — Use Size 0 40CP22F* 40DP22F* 40EP22F* — Use Size 0 40CP22H* 40DP22H* 40EP22H* — Use Size 0 40CP220* 40DP220* 40EP220* — Vacuum Contactors, 3-Phase, 3-Pole a Max Hp 200V 40 75 150 230V 50 100 200 Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating. a Dual voltage coils not available for vacuum contactors. Refer to Page 17-108 for a complete list of available coil voltages. Product Category: NEMA b For 460V 575V 100 200 400 100 200 400 Contactor Amp Rating 135 270 540 conduit hubs and conversion instructions, see page 17-99. order single phase contactor in an extra wide enclosure, order the enclosure kit from Page 17-102 and the open style contactor as separate items. c To NEMA Size 4 5 6 Open Type Catalog Number 40JV32A* 40LV32A* 40MV32A* List Price $ d Coils D, F, or G will be wired for incoming voltage. J coil will be wired for separate source. Coils E, H, and L do not apply to single phase starters. e 1 NO Auxiliary. Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog 17-45 CONTROL PRODUCTS Fiberglass Watertight, Dust-tight Watertight, Dust-tight Corrosion Resistant Corrosion Resistant 304 Stainless Steel Cont- actor General Purpose 17 Max Hp