Vacuum Contactors, Class 40

Heavy Duty Contactors
Single Phase, 4-Pole & Vacuum, Class 40
Selection
Ordering Information
Coil Table
R eplace the (*) with a letter from the coil table.
Dual voltage coils are wired on high voltage unless
specified on order.
 Field Modification Kits see page 17-93.
 Factory Modifications see page 17-108.
 Dimensions see pages 17-120 open and
17-129 enclosed.
 Wiring Diagrams see page 17-155.
 Replacement Parts see page 17-170.
60Hz Voltage
24 Separate Control
120 Separate Control
110–120/220–240a
200–208
220–240
277
220–240/440–480a
440–480
575–600

Letter­
J
F
A
D
G
L
C
H
E
For other voltages and frequencies,
see Factory Modifications page 17-108.
Open Type & Standard Width Enclosure, Single Phase, 2-Pole cd
Max Hp
Enclosure
Open Typee NEMA 1
NEMA 4/4X
Stainlessb General Purposes
NEMA 4X
Fiberglass
Watertight, Dust-tight
Watertight, Dust-tight
Corrosion Resistant
Corrosion Resistant
304 Stainless Steel
Cont-
208/ actor
NEMA 7 & 9
NEMA 3 & 4
Div 1 and Div 2
Class I Groups C & D
Class II Groups E, F & G
Class III
Bolted Enclosure
Indoor/Outdoor Use
NEMA 12
NEMA 3/3R b
Industrial Use
Weatherproof
115 230 Amp NEMA Half
Volts Volts Rating Size
Size Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $
1
2
3
5
7 1⁄2
10
15
—
—
9
18
27
35
45
60
90
115
135
00
0
1
1P
2
—
3
—
4
40BP12A*
40CP12A*
40DP12A*
40EP12A*
40FP12A*
40GP12A*
40HP12A*
40IP12A*
40JG12A*
—
—
—
—
—
21⁄2
—
31⁄2
—
40BP12B*
40CP12B*
40DP12B*
40EP12B*
40FP12B*
40GP12B*
40HP12B*
40IP12B*
40JG12B*
Use Size 0
40CP12W*
40DP12W*
40EP12W*
40FP12W*
40GP12W*
40HP12W*
40IP12W*
40JG12W*
—
Use Size 0
40CP12F*
40DP12F*
40EP12F*
40FP12F*
40GP12F*
40HP12F*
40IP12F*
40JG12F*
—
Use Size 0
40CP12H*
40DP12H*
40EP12H*
40FP12H*
40GP12H*
40HP12H*
40IP12H*
40JG12H*
—
Use Size 0
40CP120*
40DP120*
40EP120*
40FP120*
40GP120*
40HP120*
40IP120*
40JG120*
—
NEMA & General
Purpose Control
1⁄3
1
2
3
3
5
7 1⁄3
—
—
Open Type & Standard Width Enclosure, 4-Pole
Enclosure
Open Type
NEMA 1
NEMA 4/4X
Stainless b
NEMA 4X
NEMA 7 & 9
NEMA 3 & 4
NEMA 12
NEMA 3/3R b
Div 1 and Div 2
Industrial Use
Class I Groups C & D
Weatherproof
Class II Groups E, F & G
Class III
Bolted Enclosure
Indoor/Outdoor Use
200 230 460 575 Amp NEMA Half
Volts Volts Volts Volts Rating Size Size Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog No List Price $ Catalog NoList Price $
⁄3
2
3
5
1
1 1⁄2
3
7 1⁄2
10
2
5
10
15
2
5
10
15
9
18
27
40
00
0
1
—
—
—
—
13⁄4
40BP22A*
40CP22A*
40DP22A*
40EP22A*
40BP22B*
40CP22B*
40DP22B*
40EP22B*
Use Size 0
40CP22W*
40DP22W*
40EP22W*
—
Use Size 0
40CP22F*
40DP22F*
40EP22F*
—
Use Size 0
40CP22H*
40DP22H*
40EP22H*
—
Use Size 0
40CP220*
40DP220*
40EP220*
—
Vacuum Contactors, 3-Phase, 3-Pole a
Max Hp
200V
40
75
150
230V
50
100
200
Note: Hp’s shown above are based on the overload amp
range for the FLA’s (per the National Electric Code)
of typical industrial motors. All starter sizes carry
one ­maximum Hp rating.
a Dual
voltage coils not available for vacuum contactors.
Refer to Page 17-108 for a complete list of available coil voltages.
Product Category: NEMA
b For
460V
575V
100
200
400
100
200
400
Contactor
Amp
Rating
135
270
540
conduit hubs and conversion instructions, see
page 17-99.
order single phase contactor in an extra wide enclosure, order the enclosure kit from Page 17-102 and the open
style contactor as separate items.
c To
NEMA
Size
4
5
6
Open Type
Catalog Number
40JV32A*
40LV32A*
40MV32A*
List Price $
d Coils
D, F, or G will be wired for incoming voltage.
J coil will be wired for separate source. Coils E, H,
and L do not apply to single phase starters.
e 1 NO Auxiliary.
Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
17-45
CONTROL
PRODUCTS
Fiberglass
Watertight, Dust-tight Watertight, Dust-tight
Corrosion Resistant
Corrosion Resistant
304 Stainless Steel
Cont- actor
General Purpose
17
Max Hp