NOxMAT 600 Product Bulletin Features • Measures from ppb to 3,000 ppm Full Scale (NO/Nox) • Four User Programmable Ranges from 0-1 ppm to 0-3,000 ppm • Fast Response Time • Auto Ranging • Auto Calibration • Output Options: Analog (User Scalable), Digital (RS232) including AK Protocol & TCP/IP • Displays & Outputs: NO/Nox/NO2 with Adjustable Time & Hold, Diagnostics, Alarms & Preventative Maintenance • Remote Monitoring and Control • Electronic Sample & Ozone Flow Control usa.siemens.com/analyticalproducts Description The NOxMAT Model 600 CLD NO/NOx digital analyzer is designed around a state-of-the-art 16-bit microprocessor, with 16 digital inputs, 16 digital outputs, 16 analog inputs and 4 analog outputs. The analyzer can be manually operated from the keypad or remotely via TCP/IP, RS- 232C communications and discrete inputs. The analyzer display includes screen presentation of all analyzer alarms. Four levels of password protection are provided. For precision measurements, the analyzer’s accuracy is increased by entering calibration curve fit polynomials. Automatic calibration may be activated locally or remotely and includes auto cal via preset times. The analyzer may also display NO, NOx and NO2 via selectable time and hold commands. Method of Operation The NOxMAT 600 CLD Analyzer utilizes the principle of chemiluminescence for analyzing the NO or NOx concentration within a gaseous sample. In the NO mode, the method is based upon the chemiluminescent reaction between ozone and nitric oxide (NO) yielding nitrogen dioxide (NO2) and oxygen. This reaction produces light which has an intensity proportional to the mass flow rate of NO into the reaction chamber. The light is measured by means of a photodiode and associated amplification electronics. In the NOx mode, NO plus NO2 is determined as above, however, the sample is first routed through the internal NO2 in the sample to NO. The resultant reaction is then directly proportional to the total concentration of NOx. Local operation is simplified using the 20 button alphanumeric keypad with data presented on a back lit LCD display. All local operations may be performed remote via RS-232 and/or TCP/IP. Applications • Stack Gases (CEM) • Scrubber Efficiency • Turbine/Generator Feedback Control • Process Chemical Gas Analysis • Personnel Safety • Power Plant Stack De-Nitrification • Vehicle Emissions Specifications Detector: Chemiluminescence (CLD) Photodiode (thermally stabilized with Peltier Cooler) NO/NOx RANGES: 0-1 * to 3,000 ppm NO or NOx (Four user programmable ranges) (Higher ranges available upon request) Response Time: T90 < 2 Seconds to 60 Seconds Adjustable Resolution: 10 ppb NO/NOx (Displays 5 significant digits) Repeatability: Better than 0.5% of Full Scale Linearity: Better than 0.5% of Full Scale Noise*: Less than 1 % of Full Scale (*1.5% @ 0-1 ppm Full Scale) Zero & Span Drift: Less than 1 % of Full Scale per 24 Hours Zero & Span Adjustment: Via front panel, TCP/IP or RS-232 NH3, HCN & SO2 Effect: Not detectable with 100 ppm CO2 Effect: Less than 1 % with 10% CO2 H2O Effect: Less than 1 % with 1 % H2O Sample Gas Pressure: 8-25 psig (Standard model) Sample Flow Rate: 1.5 to 2.0 LPM (Consult factory for other flow rates) Converter: Vitreous Carbon Material @ 205.C > 98% efficiency Ozonator: Ultraviolet Lamp Air Or O2 Requirements: Less than 0.01 ppm NOx at 350 cc/Min. @ 25 psig (Dew Point < -35°C) NO/NOx Control: Manual/Remote/Auto Cycle (Remote NOx mode by dry contact closure) Outputs Available: TCP/IP, RS232, Four Scalable Analog 0- 10 V/420 mA Discrete Alarms: (Local & Remote Adjustable) General Fault! TTL Logic (Ground True) Calibration Failure/ TTL Logic (Ground True) High Concentration (2 each)/ TTL Logic (Ground True) Digital Diagnostics: Control Voltages, Temperatures, Pressures, Flow Parameters Keypad Displays: Factory Settings,TCP/IP Address, Passwords (4), Scalable Analog Output Voltages, Full Scale Range Select, Auto Cal Times Special Features: Calculated NO2 derived from NOx converter efficiency, Auto Ranging, Auto Calibration (adjustable through internal clock) Less than 3 cc Gold Plated Reaction Chamber Display: 3” x 5” Back lit LCD Sample Temperature: Up to 50.C Noncondensing Ambient Temperature: 5 to 40.C For more information, please contact: Siemens Industry, Inc. 5980 West Sam Houston Parkway North Suite 500 Houston, TX 77041 Phone: 713-939-7400 [email protected] Siemens Industry, Inc. 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-964-4114 [email protected] Ambient Humidity: Less than 90% RH Noncondensing Warm-Up Time: 1 Hour (Typical) Fittings: 1/4 Inch Tube Power Requirements: 115/230 (:t100;0) VAC; 50/60 Hz; 200 Watts (350 watts with pump) Dimensions: 5 1/4 H x 19 W x 17 D (Inches) - short case Weight: 45 Pounds Subject to change without prior notice Order No.: PIAFL-00061-1115 Printed in USA All rights reserved © 2015 Siemens Industry, Inc. usa.siemens.com/analyticalproducts The information provided in this flyer contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.