© Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 3100 and MAG 3100 HT ■ Overview ■ Design • • • • • • • • Compact or remote mounting possible Easy “plug & play“ field changeability of transmitter Ex ATEX and FM/CSA versions High temperature sensor for applications with temperatures up to 180 °C (356 °F) Approvals for PTB and OIML R 117 Meets EEC directives: PED, 2014/68/EU pressure directive for EN1092-1 flanges Build-in length according to ISO 13359, the standard includes sizes up to DN 400 Onsite or factory upgrade to IP68/NEMA 6P of a standard sensor. ■ Mode of operation The flow measuring principle is based on Faraday’s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to the velocity of the flow. ■ Integration The SITRANS F M MAG 3100 is an electromagnetic flow sensor in a large variety that meets the demands of almost every flow application. ■ Benefits The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to a variety of fieldbus systems such as HART, FOUNDATION Fieldbus H1, DeviceNet, PROFIBUS DP and PA, Modbus RTU/RS 485. • Wide range of sizes: DN 15 to DN 2000 (½” to 78”) • The flexible design is for all applications not covered by the standard industry-specific sensors: MAG 1100, MAG 1100 F, MAG 3100 P and MAG 5100 W • Wide pressure range: PN 6 to PN 100 ANSI Class 150/300, AS 2129, AS 4087, JIS K10 and K20. On request up to 690 bar (10 000 psi) • Wide range of electrode and liner material to fit even the most extreme process media • Fully welded construction provides a ruggedness that suits the toughest applications and environments • Easy commissioning, the SENSORPROM unit automatically updates settings. • Designed to allow patented SITRANS F M in-situ verification using the SENSORPROM fingerprints. ■ Application The main applications of the SITRANS F M electromagnetic flow sensors can be found in the following fields: • Process industry • Chemical industry • Steel industry • Mining • Utility • Power generation and distribution • Oil and gas / HPI • Water and waste water Siemens FI 01 · 2016 3/69 3 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 3100 and MAG 3100 HT Pressure/temperature curve; material AISI 316L/1.4404 AS 2129, Class E Pressure/temperature curve to EN (DIN) flanges AISI 304 Pressure - Temperature curve to EN (DIN) AISI 304 Pressure/temperature curve; material AISI 316L/1.4404 AS 2129, Class E bar 16 Class E 14 3 100 90 80 12 70 10 bar 60 8 50 40 6 PN 40 4 30 20 PN 25 2 10 PN 16 PN 10 PN 6 0 -50 0 50 100 150 200 250 300 0 °C -20 ºC 100 150 180 Pressure - Temperature curve to EN (DIN) Flanges AISI 316 Pressure/temperature curve - JIS 2200 100 bar 40 90 20K 80 70 30 25 bar 60 50 20 15 50 Pressure/temperature curve to EN (DIN) flanges AISI 316 Pressure/temperature curve - JIS 2200 35 -10 40 10K PN 40 30 10 20 5 10 0 -30 ºC 20 70 120 170 220 0 270 Pressure/temperature curve to EN (DIN) flanges, material A 105 carbon steel PN 25 PN 16 PN 10 -20 -10 50 ºC 100 150 Pressure/temperature curve to ANSI B16.5 flanges Pressure - temperature curve to ANSI B16.5 flanges Pressure - temperature curve to EN (DIN) flanges material A 105 carbon steel 800 120 100 700 PN 100 500 80 bar psi PN 63 60 40 0 400 300 A 105 class 150 PN 40 200 PN 25 20 A 105 class 300 600 PN 16 PN 10 PN 6 -20 AISI 316 class 150 AISI 304 class 150 100 0 -10 50 ºC 100 150 180 -20 100 200 ºF 300 400 Note: The pressure-temperature curves only assist in the selection of a system. No responsibility is taken for the correctness of the information. For further information on the PED standard and requirements, see page 9/6. 3/70 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 3100 and MAG 3100 HT ■ Technical specifications Version MAG 3100 MAG 3100 HT (High Temperature) Product characteristic Flexible product program Flexible product program Nominal size DN 15 ... DN 2000 (½” ... 78“) DN 15 … DN 300 (½“ ... 12“) Measuring principle Electromagnetic induction Electromagnetic induction Excitation frequency (Mains supply: 50 Hz/60 Hz) • DN 15 ... 65 (½“ … 2½”): 12.5 Hz/15 Hz • DN 80 ... 150 (3” ... 6”): 6.25 Hz/7.5 Hz • DN 200 ... 1200 (8” ... 48”): 3.125 Hz/3.75 Hz • DN 1400 ... 2000 (54” ... 78”): 1.5625 Hz/1.875 Hz • DN 15 ... 65 (½“ … 2½”): 12.5 Hz/15 Hz • DN 80 ... 150 (3” ... 6”): 6.25 Hz/7.5 Hz • DN 200 ... 300 (8” ... 12”): 3.125 Hz/3.75 Hz EN 1092-1, raised face1) (EN 1092-1, DIN 2501 and BS 4504 have the same mating dimensions) • DN 65 ... 2000 (2½“ … 78”): PN 6 (87 psi) • DN 200 ... 2000 (8“ … 78“): PN 10 (145 psi) • DN 65 ... 2000 (2½“ … 78“): PN 16 (232 psi) • DN 200 ... 600 (8“ … 24”): PN 25 (362 psi) • DN 15 ... 600 (½“ … 24”): PN 40 (580 psi) • DN 50 ... 300 (2“ … 12“): PN 63 (913 psi) • DN 25 ... 300 (1“ … 12“): PN 100 (1450 psi) ANSI B16.5 (~BS 1560), raised face • ½” ... 24”: Class 150 (20 bar (290 psi)) • ½” ... 24”: Class 300 (50 bar (725 psi)) AWWA C-207, flat face 28” ... 78”: Class D (10 bar) AS 2129, raised face ½” ... 48”: Table E AS 4087, raised face: • PN 16 (DN 50 ... 1200, 16 bar (232 psi)) • PN 21 (DN 50 ... 600, 21 bar (304 psi)) • PN 35 (DN 50 ... 600, 35 bar (508 psi)) JIS B 2220:2004 • K10 (1" ... 24") • K20 (1" ... 24") Other flanges and pressure ratings on request EN 1092-1, raised face (EN 1092-1, DIN 2501 and BS 4504 have the same mating dimensions) • DN 15 ... 300 (½“ … 12”): PN 40 (580 psi) • DN 65 ... 300 (2½“ … 12”): PN 16 (232 psi) • DN 200 ... 300 (8“ … 12“): PN 10 (145 psi) • DN 200 ... 300 (8“ … 12”): PN 25 (362 psi) • Standard sensor -40 … +100 ºC (-40 … +212 °F) -40 … +100 ºC (-40 … +212 °F) • Ex sensor -20 … +60 ºC (-4 … +140 °F) For medium temperature up to 150 °C (302 °F): -20 … +60 ºC (-4 … +140 °F) For medium temperature 150 ... 180 °C (302 ... 356 °F): -20 … +50 ºC (-4 … +122 °F) - MAG 5000/60002) -20 … +60 ºC (-4 … +140 °F) -20 … +60 ºC (-4 … +140 °F) - MAG 6000 I -20 … +60 ºC (-4 … +140 °F) -20 … +60 ºC (-4 … +140 °F) - MAG 6000 I Ex -20 … +60 ºC (-4 … +140 °F) -20 … +60 ºC (-4 … +140 °F) 3 Process connection Flanges ANSI B16.5 (~BS 1560), raised face: • ½” ... 12”: Class 150 (20 bar (290 psi)) • ½” ... 12”: Class 300 (50 bar (725 psi)) AS 2129, raised face ½” ... 12”: Table E Other flanges and pressure ratings on request Rated operation conditions Ambient temperature (conditions also dependent on liner characteristiques) • With compact transmitter Siemens FI 01 · 2016 3/71 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 3100 and MAG 3100 HT Version 3 MAG 3100 MAG 3100 HT (High Temperature) Operating pressure [abs. bar] • Soft rubber 0.01 ... 100 bar (maximum operating pressure (0.15 ... 1450 psi) decreases with increasing operat- • EPDM 0.01 ... 40 bar (0.15 ... 580 psi) ing temperature and with stain• Linatex 0.01 ... 40 bar less steel flanges) (0.15 ... 580 psi) • Ebonite 0.01 ... 100 bar (0.15 ... 1450 psi) • PTFE - DN 300 ( 12“): 0.3 ... 50 bar (4 ... 725 psi) - 350 DN 600 (14“ DN 24“): 0.3 ... 40 bar (4 ... 580 psi) • PFA - DN 15 ... 150 (½“ … 6”): Vacuum 0.02 ... 50 bar (0.29 ... 725 psi) • PTFE Teflon - DN 15 ... 300 (½“ … 12”) (130/180 °C (266 °F/356ºF)): 0.3/0.6 ... 50 bar (4/8 ... 725 psi) (180 ºC (356 ºF) PTFE has factory mounted grounding SS rings type E and SS terminal box) • PFA - DN 15 ... 150 (½“ … 6”): Vacuum 0.02 ... 50 bar (0.29 ... 725 psi) Enclosure rating IP67 to EN 60529/NEMA 4X/6, 1 mH2O for 30 min Option: IP68 to EN 60529/NEMA 6P, 10 mH2O cont. IP67 to EN 60529/NEMA 4X/6, 1 mH2O for 30 min Option: IP68 to EN 60529/NEMA 6P, 10 mH2O cont. Pressure drop at 3 m/s As straigth pipe 1.5 x PN (where applicable) Test pressure Mechanical load (vibration) • 18 ... 1000 Hz random in x, y, z, directions for 2 hours according to EN 60068-2-36 • Sensor: 3.17 g RMS • Sensor with compact MAG 5000/ 6000 mounted transmitter: 3.17 g RMS • Sensor with compact MAG 6000 I/ 6000 I Ex mounted transmitter: 1.14 g RMS • 18 ... 1000 Hz random in x, y, z, directions for 2 hours according to EN 60068-2-36 • Sensor: 3.17 g RMS • Sensor with compact MAG 5000/ 6000 mounted transmitter: 3.17 g RMS • Sensor with compact MAG 6000 I/ 6000 I Ex mounted transmitter: 1.14 g RMS Temperature of medium • Soft rubber 0 … +70 °C (32 … 158 °F) • EPDM -10 … +70 °C (14 … 158 °F) • Linatex (rubber) -40 … +70 °C (-40 … +158 °F) (for temperatures below -20 °C (-4 °F) AISI 304 or 316 flanges must be used) • Ebonite 0 … 95 °C (32 … 203 °F) • PTFE -20 … +100 °C (-4 … +212 °F) • PFA -20 … +100 °C (-4 … +212°F) • PTFE -20 … +130 °C (-4 … +266 °F) • PTFE -20 … +180 °C (-4 ... +356 °F) Factory mounted grounding rings type E in SS and SS terminal box. Can only be used with remote transmitter. • PFA -20 … +150 °C (-4 … +300 °F) EMC 2014/30/EU 2014/30/EU Design Weight See dimensional drawings Flange and housing material Carbon steel ASTM A 105, with corrosion resistant two component epoxy coating Corrosivity category C4, according to ISO 12944-2 or Stainless steel AISI 304/1.4301 flanges and carbon steel housing, with corrosion resistant two component epoxy coating Corrosivity category C4, according to ISO 12944-2 or Stainless steel AISI 316L/1.4404 flanges and housing, polished Carbon steel ASTM A 105, with corrosion resistant two component epoxy coating Corrosivity category C4, according to ISO 12944-2 or AISI 304/1.4301 flanges and carbon steel housing, with corrosion resistant two component epoxy coating Corrosivity category C4, according to ISO 12944-2 or AISI 316L/1.4404 flanges and housing, polished Measuring pipe material Stainless steel AISI 304/1.4301 AISI 304/1.4301 Electrode material • Stainless steel AISI 316Ti/1.4571 • Hastelloy C276/2.4819 (PFA: Hastelloy C22/2.4602) • Platinum/Iridium • Titanium • Tantalum • AISI 316Ti/1.4571 • Hastelloy C276/2.4819 (PFA: Hastelloy C22/2.4602) • Platinum/Iridium • Titanium • Tantalum Grounding electrode material • Soft rubber, EPDM, Linatex, Ebonite: available with measuring electrodes in stainless steel AISI 316Ti/1.4571 or Hastelloy • PTFE: optional in Hastelloy, Tantalum or Platinum • PFA: optional in Hastelloy, Tantalum or Platinum • PTFE: none • PFA: optional in Hastelloy, Tantalum or Platinum 3/72 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 3100 and MAG 3100 HT Version MAG 3100 MAG 3100 HT (High Temperature) Terminal box (remote version only) • Standard fibre glass reinforced polyamide • Option Stainless steel AISI 316/1.4436 • Ex Stainless steel AISI 316/1.4436 • Standard fibre glass reinforced polyamide (max. 150 °C (302 °F)) • Stainless steel AISI 316/1.4436 • Ex Stainless steel AISI 316/1.4436 Cable entries • Remote installation 2 x M20 or 2 x ½" NPT • Compact installation - MAG 5000/MAG 6000: 4 x M20 or 4 x ½” NPT - MAG 6000 I: 2 x M25 or 2 x ½" NPT (for supply/output) - MAG 6000 I Ex: 2 x M25 or 2 x ½" NPT (for supply/output) • Remote installation 2 x M20 or 2 x ½" NPT Design (continued) 3 Certificates and approvals Calibration • Standard production calibration Zero-point, 2 x 25 % and 2 x 90 % (default) (default), calibration report shipped with sensor Zero-point, 2 x 25 % and 2 x 90 % (default) • Special calibration 5-point calibration: 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax 10-point calibration: ascending and descending at 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax Matched-pair calibration: default, 5-point or 10-point Conforms to PED (All EN1092-1 flanges conforms to PED) – 2014/68/EU3) CMC/CPA PED (All EN1092-1 flanges conforms to PED) – 2014/68/EU3) CMC/CPA Material certificate EN 10204-3.1 Available when ordering together with meter4) Available when ordering together with meter4) Pressure test certificate Available when ordering together with meter4) Available when ordering together with meter4) Ex sensors • ATEX 2 GD DN 15 ... 300: EEx d e ia IIC T4 - T6 • DN 350 ... 2000: EEx e ia IIC T4 - T6 • IEC Ex de ia IIC T3-T6 • FM Class I/II/III, Div 16) • FM Class I, Zone 1/21 • CSA Class I, Zone 1 Standard sensors • FM Class I, Div 2/Zone 2 • CSA Class I, Div 2/Zone 2 Ex sensors • ATEX 2 GD DN 15 ... 300: EEx d e ia IIC T3 - T6 • IEC Ex de ia IIC T3-T6 • FM Class I/II/III, Div 16) • FM Class I, Zone 1/21 • CSA Class I, Zone 1 Ex approvals5) Drinking water approvals EPDM lining: • WRAS (WRc, BS690 cold water, GB) • NSF/ANSI Standard 617) (Cold water, US) • ACS listed (F) • DVGW W270 (D) • Belgaqua (B) • MCERTS (GB) (EPDM or PTFE lining with AISI 316 or Hastelloy electrodes) Custody transfer (CT) ( DN2000) (only together with MAG 5000/ 6000 CT), order as special Cold water pattern approval - DANAK TS 22.36.001, PTB (Denmark and Germany) Other media than water - OIML R 117 (Denmark) Standard sensors • FM Class I, Div 2/Zone 2 • CSA Class I, Div 2/Zone 2 Technical specification for transmitter - see transmitter pages. 1) PN 6-40: DN 600 type 01 (SORF); DN > 600 type 11 (WNRF); PN 63-100: type 11 (WNRF) 2) With compact transmitter MAG 5000 CT/6000 CT -20 ... +50 °C (-4 ... +122 °F). 3) For sizes larger than 600 mm (24”) in PN 16 PED conformity is available as a cost-added option. The basic unit will carry the LVD (Low Voltage Directive) and EMC approval. All products sold outside of EU and EFTA are excluded from the Pressure Equipment directive, also products sold into certain market sectors are excluded. These include: a) Meters used in networks for the supply, distribution and discharge of water. b) Meters used in pipelines for the conveyance of any fluid from offshore to onshore. c) Meters used in the extraction of petroleum or gas, including christmas tree and manifold equipment. d) Any meter mounted on a ship or mobile offshore platform. For further information on the PED standard and requirements see page 9/6. 4) Has to be ordered with the meter. It is not possible to order the certificate afterwards. 5) Not for sensors with 300 m coating. 6) Only with sensors sizes DN 15 ... 300 (½" ... 12") compact. 7) Including Annex G Siemens FI 01 · 2016 3/73 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 3100 and MAG 3100 HT Selection and Ordering data Article No. Selection and Ordering data Article No. Sensor SITRANS F M MAG 3100 7 ME 6 3 1 0 - Sensor SITRANS F M MAG 3100 7 ME 6 3 1 0 - 77777 - 7777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Diameter 3 DN 15 (½“) (PTFE and PFA liner) DN 25 (1“) DN 40 (1½“) 1V 2D 2R DN 50 (2“) DN 65 (2½“) DN 80 (3“) 2Y 3F 3M DN 100 (4“) DN 125 (5“) DN 150 (6“) 3T 4B 4H DN 200 (8“) DN 250 (10“) DN 300 (12“) 4P 4V 5D DN 350 (14“) DN 400 (16“) DN 450 (18“) 5K 5R 5Y DN 500 (20“) DN 600 (24“) DN 700 (28“) 6F 6P 6Y DN 750 (30“) (AWWA and AS 2129 only) DN 800 (32“) DN 900 (36“) 7D 7H 7M DN 1000 (40“) DN 1050 (42“) (AWWA only) DN 1100 (44“) (AWWA only) 7R 7U 7V DN 1200 (48“) DN 1400 (54“) DN 1500 (60“) 8B 8F 8K DN 1600 (66“) DN 1800 (72“) DN 2000 (78“) 8P 8T 8Y 77777 - 7777 Flange material and coating Carbon steel flanges ASTM A 105, 150 m coating Stainless steel flanges, AISI 304/1.4301, 150 m coating Stainless steel flanges and sensor body, AISI 316L/1.4404, polished Carbon steel flanges ASTM A 105, 300 m coating Stainless steel flanges, AISI 304/1.4301, 300 m coating 1 2 3 4 5 Liner material Soft rubber EPDM PTFE (DN 300, PN 50 bar / 12“, PN 725 psi), PTFE (350 DN 600, PN 40 bar / 14“ DN 24“, PN 580 psi) Ebonite Linatex (PN 40 bar (580 psi) DN 600 (24“)) PFA (DN 15 ... 150 (½" ... 6")) (PN 40 bar (580 psi)) 1 2 3 2) 4 5 7 2) Electrode material (Grounding electrodes not for pressure rating PN 100) AISI 316Ti/1.4571 (not for PFA) Hastelloy C276/2.4819 (PFA liner: Hastelloy C22/2.4602) Platinum (DN 300 (12")) (not ebonite liner) 1 2 Titanium (not PFA liner) (DN 600 (24")) Tantalum (DN 600 (24")) (not ebonite liner) Hastelloy C incl. grounding electrodes (only PTFE and PFA) 4 5 6 Platinum incl. grounding electrodes (only PTFE and PFA) Tantalum incl. grounding electrodes (only PTFE and PFA) 7 Transmitter with display Standard sensor for remote transmitter (Order transmitter separately) Ex sensor for remote transmitter (Order transmitter separately) MAG 6000 I, Alu.18 ... 90 V DC, 115 ... 230 V AC 3 8 A B Flange norm and pressure rating EN 1092-1 PN 6 (DN 65 ... 2000 (2½“ ... 78“)) PN 10 (DN 200 ... 2000 (8“ ... 78“)) PN 16 (DN 65 ... 1200 (2½“ ... 48“)) A B C MAG 6000 I Alu. 18 ... 30 V DC, Ex MAG 6000 I Alu. 115 ... 230 V, Ex MAG 6000 Polyamide, 11… 30 V DC / 11…24 V AC D E H PN 16, non-PED (DN 700 ... 2000 (28“ ... 78“)) PN 25 (DN 200 ... 600 (8“ ... 24“))1) PN 40 (DN 15 ... 600 (½“ ... 24“)) D E F MAG 6000, Polyamide, 115 ... 230 V AC MAG 5000, Polyamide, 11… 30 V DC / 11…24 V AC MAG 5000, Polyamide, 115 ... 230 V AC J K L PN 63 (DN 50 ... 300 (2“ ... 12“)) PN 100 (DN 25 ... 300 (1“ ... 12“)) G H ANSI B16.5 Class 150 (½“ ... 24“) Class 300 (½“ ... 24“) J K AWWA C-207 Class D (28“ ... 78“) L Communication No communication, add-on possible HART PROFIBUS PA Profile 3 (only MAG 6000/MAG 6000 I) PROFIBUS DP Profile 3 (not for Ex) (only MAG 6000/MAG 6000 I) Modbus RTU/RS 485 (not for Ex) (only MAG 6000/MAG 6000 I) FOUNDATION Fieldbus H1 (only MAG 6000/MAG 6000 I) AS 2129, table E 4087, PN 16 (DN 50 ... 1200 (2“ ... 48“)) (Not PTFE and PFA) 4087, PN 21 (DN 50 ... 600 (2“ ... 24“)) (Not PTFE and PFA) 4087, PN 35 (DN 50 ... 600 (2“ ... 24“)) (Not PTFE and PFA) JIS B 2220:2004 K10 (1" ... 24") K20 (1" ... 24") M N P Q R S C A B F G E J Cable glands/terminal box Metric: Polyamide terminal box or 6000 I compact ½" NPT: Polyamide terminal box or 6000 I compact Metric: SS terminal box (mandatory for stainless steel MAG 6000 Transmitter) ½" NPT: SS terminal box (mandatory for stainless steel MAG 6000 Transmitter) 1) Under preparation 2) Some variants are available with Quick Ship delivery as MAG 3100 P (7ME634) 1 2 3 4 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. 3/74 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 3100 and MAG 3100 HT Selection and Ordering data Order code Operating instructions for SITRANS F M MAG 3100 Additional information Description Article No. Please add “-Z“ to Article No. and specify Order code(s) and plain text. • English A5E03005599 • German A5E03086288 Pressure test certificate according to EN 10204-3.1 C01 Material certificate according to EN 10204-3.1 C12 Factory certificate according to EN 10204-2.2 C14 Factory certificate according to EN 10204-2.1 C15 Region specific approvals and certificates This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Accessories W06 Description • KCC label W28 Potting kit for terminal box of FDK:085U0220 flow sensors for IP68/NEMA 6P Special calibration 3 Article No. • Chinese label translation • 5-point calibration for DN 15 ... DN 2001) • 5-point calibration for DN 250 ... DN 6001) • 5-point calibration for DN 700 ... DN 12001) D01 D02 D03 • 10-point calibration for DN 15 ... DN 2002) • 10-point calibration for DN 250 ... DN 6002) • 10-point calibration for DN 700 ... DN 12002) D06 D07 D08 • Default (2 x 25 % and 2 x 90 %) match-pair calibration for DN 15 ... DN 200 • Default (2 x 25 % and 2 x 90 %) match-pair calibration for DN 250 ... DN 600 • Default (2 x 25 % and 2 x 90 %) match-pair calibration for DN 700 ... DN 1200 D11 D13 MAG 5000/6000 transmitters and sensors are packed in separate boxes, the final assembly takes place during installation at the customer's place. MAG 6000 I/MAG 6000 I ATEX 2G D transmitters and sensors are delivered compact mounted from factory. • 5-point, matched-pair calibration for DN 15 ... DN 2001) • 5-point, matched-pair calibration for DN 250 ... DN 6001) • 5-point, matched-pair calibration for DN 700 ... DN 12001) D15 Communication module will be pre-mounted in the transmitter. • 10-point, matched-pair calibration for DN 15 ... DN 2002) • 10-point, matched-pair calibration for DN 250 ... DN 6002) • 10-point, matched-pair calibration for DN 700 ... DN 12002) D18 Terminal blocks • Factory mounted terminal blocks D12 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Please use online Product selector to get latest updates. Product selector link: www.pia-portal.automation.siemens.com D16 D17 D19 D20 N02 Tag name plate, stainless steel fixed with SS wire (add plain text) Y17 Tag name plate, plastic (self adhesive) Y18 Customer-specific converter setup Y20 Sensor cables wired (specify cable Article No.) Y40 Sensor for remote transmitter's junction box potted to IP68 with wired cable (specify cable Article No.) (not for Ex) Y41 Other postproduction requirements (add desired text) Y99 Additional calibrations • Accredited Siemens Flow Instruments matched pair Calibration acc. to ISO/IEC 17025: 2005 On request3) • CT verification and authority seal according to: Cold water pattern approval - DANAK TS 22.36.001, PTB (Denmark and Germany) On request3) • Customer-witnessed calibration Any of above calibration On request3) 1) 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax 2) Ascending and descending at 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax 3) Ordering On request as dedicated information from the customer on the individual sensors is required. Siemens FI 01 · 2016 3/75 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 3100 and MAG 3100 HT Selection and Ordering data Article No. Selection and Ordering data Article No. Sensor SITRANS F M MAG 3100 HT (High Temperature) 7 ME 6 3 2 0 - Sensor SITRANS F M MAG 3100 HT (High Temperature) 7 ME 6 3 2 0 - 77777 - 7777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Diameter 3 77777 - 7777 Communication DN 15 (½“) DN 25 (1“) DN 40 (1½“) 1V 2D 2R DN 50 (2“) DN 65 (2½“) DN 80 (3“) 2Y 3F 3M DN 100 (4“) DN 125 (5“) DN 150 (6“) 3T 4B 4H DN 200 (8“) DN 250 (10“) DN 300 (12“) 4P 4V 5D No communication, add-on possible A HART B PROFIBUS PA Profile 3 (only MAG 6000/MAG 6000 I) F PROFIBUS DP Profile 3 (only MAG 6000/MAG 6000 I) G Modbus RTU/RS 485 (only MAG 6000/MAG 6000 I) FOUNDATION Fieldbus H1 (only MAG 6000/MAG 6000 I) E J Cable glands/terminal box Metric: Polyamide terminal box (PTFE 130 °C (266 °F)) or 6000 I compact ½" NPT: Polyamide terminal box (PTFE 130 °C (266 °F)) or 6000 I compact Flange norm and pressure rating EN 1092-1 PN 10 (DN 200 ... 300 (8“ ... 12“)) PN 16 (DN 65 ... 300 (2½“ ... 12“)) PN 25 (DN 200 ... 300 (8“ ... 12“)) PN 40 (DN 15 ... 300 (½“ ... 12“)) B C E F ANSI B16.5 Class 150 (½“ ... 12“) Class 300 (½“ ... 12“) J K AS 2129, table E M 1 2 3 Metric: SS terminal box (mandatory for Stainless steel MAG 6000 Transmitter) ½" NPT: SS terminal box (mandatory for Stainless steel MAG 6000 Transmitter) Selection and Ordering data 4 Order code Additional information Please add “-Z“ to Article No. and specify Order code(s) and plain text. Pressure test certificate according to EN 10204-3.1 C01 Flange material Material certificate according to EN 10204-3.1 C12 Carbon steel flanges ASTM A 105 Stainless steel flanges, AISI 304/1.4301 Stainless steel flanges and sensor body, AISI 316L/1.4404, polished Factory certificate according to EN 10204-2.2 C14 Factory certificate according to EN 10204-2.1 C15 Liner material PTFE (130 °C (266 °F)) PTFE including type E protection rings AISI 316/1.4436 (180 °C (356 °F)) PFA (150 ºC (302 ºF)) (DN 15 ... 150 (½" ... 6")) 1 2 3 Region specific approvals and certificates 2 3 7 Electrode material • KCC label W28 Terminal blocks • Factory mounted terminal blocks N02 Customer-specific converter setup Y20 Tag name made, stainless steel fixed with SS wire (add plain text) Y17 AISI 316Ti/1.4571 (not for PFA) Hastelloy C276/2.4819 (PFA liner: Hastelloy C22/2.4602) Platinum 1 2 Tag name plate, plastic (self adhesive) Y18 Sensor cables wired (specify cable Article No.) Y40 3 Y41 Titanium (not for PFA) Tantalum Hastelloy C22/2.4602 incl. grounding electrodes (only PFA) 4 5 6 Sensor for remote transmitter's junction box potted to IP68 with wired cable (specify cable Article No.) (not for Ex) Other postproduction requirements (add desired text) Y99 Platinum incl. grounding electrodes (only PFA) Tantalum incl grounding electrodes (only PFA) 7 8 Additional calibrations Transmitter with display Standard sensor for remote transmitter (Order transmitter separately) Ex sensor for remote transmitter (Order transmitter separately) MAG 6000 I, Alu.18 ... 90 V DC, 115 ... 230 V AC A MAG 6000 I, Alu. 18 ... 30 V DC, Ex MAG 6000 I, Alu. 115 ... 230 V AC, Ex MAG 6000, Polyamide, 11 ... 30 V DC/ 11 ... 24 V AC D E H MAG 6000, Polyamide, 115 ... 230 V AC MAG 5000, Polyamide, 11 ... 30 V DC/ 11 ... 24 V AC MAG 5000, Polyamide, 115 ... 230 V AC J K 3/76 Siemens FI 01 · 2016 B C L • Matched pair - (Standard production calibration where sensor and transmitter is calibrated together) On request1) • Accredited Siemens Flow Instruments matched pair Calibration acc. to ISO/IEC 17025: 2005 On request1) • Customer-specified calibration up to 10 points On request1) • CT verification and authority seal according to: Cold water pattern approval - DANAK TS 22.36.001, PTB (Denmark and Germany) On request1) • Customer-witnessed calibration Any of above calibration On request1) 1) Ordering On request as dedicated information from the customer on the individual sensors is required. © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 3100 and MAG 3100 HT Selection and Ordering data MAG 3100 and MAG 3100 HT1) Type C Grounding and protection rings 1 pc. AISI 304 grounding and protection ring type C for all liners except PTFE and PFA Type C tC DN PN 6 Article No. PN 10 Article No. PN 16 Article No. PN 25 Article No. DN 25 DN 40 DN 50 PN 40 Article No. AS 2129 Table E Article No. FDK:083N8361 FDK:083N8362 FDK:083N8344 FDK:083N8361 FDK:083N8362 FDK:083N8344 DN 65 DN 80 DN 100 FDK:083N8345 FDK:083N8347 FDK:083N8070 FDK:083N8345 FDK:083N8347 FDK:083N8025 FDK:083N8345 FDK:083N8347 FDK:083N8025 FDK:083N8346 FDK:083N8347 FDK:083N8025 DN 125 DN 150 DN 200 FDK:083N8071 FDK:083N8072 FDK:083N8074 FDK:083N8011 FDK:083N8071 FDK:083N8008 FDK:083N8011 FDK:083N8011 FDK:083N8071 FDK:083N8073 FDK:083N8075 FDK:083N8071 FDK:083N8008 FDK:083N8011 DN 250 DN 300 DN 350 FDK:083N8078 FDK:083N8080 FDK:083N8083 FDK:083N8013 FDK:083N8012 FDK:083N8039 FDK:083N8013 FDK:083N8012 FDK:083N8039 FDK:083N8013 FDK:083N8081 FDK:083N8084 FDK:083N8079 FDK:083N8082 FDK:083N8085 FDK:083N8013 FDK:083N8012 FDK:083N8039 DN 400 DN 450 DN 500 FDK:083N8099 FDK:083N8103 FDK:083N8107 FDK:083N8100 FDK:083N8103 FDK:083N8107 FDK:083N8100 FDK:083N8104 FDK:083N8108 FDK:083N8101 FDK:083N8104 FDK:083N8108 FDK:083N8102 FDK:083N8105 FDK:083N8109 FDK:083N8100 FDK:083N8104 FDK:083N8108 DN 600 DN 700 DN 750 FDK:083N8111 FDK:083N8300 FDK:083N8111 FDK:083N8294 FDK:083N8112 FDK:083N8294 FDK:083N8112 DN 800 DN 900 DN 1000 FDK:083N8303 FDK:083N8306 FDK:083N8309 FDK:083N8304 FDK:083N8307 FDK:083N8310 FDK:083N8304 FDK:083N8307 FDK:083N8310 FDK:083N8373 FDK:083N8396 FDK:083N8397 DN 1100 DN 1200 DN 1400 FDK:083N8312 FDK:083N8467 FDK:083N8367 FDK:083N8313 FDK:083N8468 FDK:083N8367 FDK:083N8313 FDK:083N8469 FDK:083N8367 FDK:083N8398 DN 1500 DN 1600 DN 1800 DN 2000 FDK:083N8471 FDK:083N8475 FDK:083N8479 FDK:083N8483 FDK:083N8472 FDK:083N8476 FDK:083N8480 FDK:083N8484 FDK:083N8473 FDK:083N8477 FDK:083N8481 FDK:083N8485 1) FDK:083N8113 FDK:083N8372 Also for MAG 5100 W (7ME6520 > DN 300; and 7ME6580). Size AWWA C-207 Size ANSI Class 150 Article No. Class 300 Article No. JIS K10 Article No. JIS K20 Article No. FDK:083N8361 1“ 1½“ FDK:083N8362 2“ FDK:083N8344 FDK:083N8361 FDK:083N8362 FDK:083N8344 FDK:083N8361 FDK:083N8362 FDK:083N8344 FDK:083N8361 FDK:083N8362 FDK:083N8344 28“ 30“ 32“ FDK:083N8302 FDK:083N8366 FDK:083N8305 2½“ FDK:083N8345 3“ FDK:083N8347 4“ FDK:083N8025 FDK:083N8345 FDK:083N8347 FDK:083N8025 FDK:083N8345 FDK:083N8347 FDK:083N8070 FDK:083N8345 FDK:083N8347 FDK:083N8025 36“ 40“ 42“ FDK:083N8308 FDK:083N8311 FDK:083N8394 5“ 6“ 8“ FDK:083N8071 FDK:083N8008 FDK:083N8011 FDK:083N8071 FDK:083N8073 FDK:083N8076 FDK:083N8071 FDK:083N8008 FDK:083N8011 FDK:083N8071 FDK:083N8008 FDK:083N8011 44“ 48“ 54“ FDK:083N8395 FDK:083N8314 FDK:083N8470 10“ 12“ 14“ FDK:083N8013 FDK:083N8012 FDK:083N8039 FDK:083N8079 FDK:083N8082 FDK:083N8085 FDK:083N8013 FDK:083N8012 FDK:083N8083 FDK:083N8079 FDK:083N8081 FDK:083N8039 16“ 18“ 20“ 24“ FDK:083N8100 FDK:083N8104 FDK:083N8107 FDK:083N8113 FDK:083N8102 FDK:083N8106 FDK:083N8110 FDK:083N8114 FDK:083N8100 FDK:083N8103 FDK:083N8107 FDK:083N8111 FDK:083N8101 FDK:083N8104 FDK:083N8108 FDK:083N8112 60“ 66“ 72“ 78“ FDK:083N8474 FDK:083N8478 FDK:083N8482 FDK:083N8486 Article No. Siemens FI 01 · 2016 3/77 3 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 3100 and MAG 3100 HT Selection and Ordering data MAG 3100 and 3100 HT Type E grounding and protection ring 1 pc. AISI 316 grounding and protection ring type E for PTFE liners incl. straps and screws Type E Note: For MAG 3100 HT High temperature version 7ME6320... for PTFE 180 °C (356 °C) versions - grounding ring type E is included and factory mounted. tE 3 DN PN 6 Article No. PN 10 Article No. PN 16 Article No. PN 25 Article No. DN 15 DN 25 DN 40 PN 40 Article No. FDK:083N8365 FDK:083N8271 FDK:083N8278 DN 50 DN 65 DN 80 FDK:083N8284 FDK:083N8288 FDK:083N8285 FDK:083N8289 FDK:083N8282 FDK:083N8286 FDK:083N8290 DN 100 DN 125 DN 150 FDK:083N8116 FDK:083N8120 FDK:083N8124 FDK:083N8117 FDK:083N8121 FDK:083N8125 FDK:083N8118 FDK:083N8122 FDK:083N8126 DN 200 DN 250 DN 300 FDK:083N8129 FDK:083N8135 FDK:083N8144 FDK:083N8130 FDK:083N8136 FDK:083N8144 FDK:083N8130 FDK:083N8137 FDK:083N8145 FDK:083N8131 FDK:083N8138 FDK:083N8146 FDK:083N8132 FDK:083N8139 FDK:083N8147 DN 350 DN 400 DN 450 FDK:083N8152 FDK:083N8160 FDK:083N8168 FDK:083N8153 FDK:083N8161 FDK:083N8169 FDK:083N8154 FDK:083N8162 FDK:083N8170 FDK:083N8155 FDK:083N8163 FDK:083N8171 FDK:083N8156 FDK:083N8164 FDK:083N8172 DN 500 DN 600 FDK:083N8177 FDK:083N8186 FDK:083N8178 FDK:083N8187 FDK:083N8179 FDK:083N8188 FDK:083N8180 FDK:083N8189 FDK:083N8181 Protection of PTFE liner use 2 pcs. Grounding of PTFE lined flowmeter use 1 pc. Size ANSI Class 150 Article No. Class 300 Article No. JIS K10 Article No. JIS K20 Article No. FDK:083N8365 ½“ 1“ FDK:083N8272 1½“ FDK:083N8279 FDK:083N8365 FDK:083N8272 FDK:083N8279 FDK:083N8271 FDK:083N8278 FDK:083N8271 FDK:083N8278 FDK:083N8283 2“ 2½“ FDK:083N8287 FDK:083N8291 3“ FDK:083N8283 FDK:083N8287 FDK:083N8292 FDK:083N8282 FDK:083N8285 FDK:083N8288 FDK:083N8282 FDK:083N8285 FDK:083N8289 4“ 5“ 6“ FDK:083N8118 FDK:083N8122 FDK:083N8126 FDK:083N8119 FDK:083N8123 FDK:083N8127 FDK:083N8116 FDK:083N8121 FDK:083N8125 FDK:083N8117 FDK:083N8122 FDK:083N8126 8“ 10“ 12“ FDK:083N8370 FDK:083N8140 FDK:083N8148 FDK:083N8133 FDK:083N8141 FDK:083N8149 FDK:083N8130 FDK:083N8137 FDK:083N8144 FDK:083N8370 FDK:083N8139 FDK:083N8146 14“ 16“ 18“ FDK:083N8157 FDK:083N8165 FDK:083N8173 FDK:083N8158 FDK:083N8166 FDK:083N8174 FDK:083N8152 FDK:083N8160 FDK:083N8169 FDK:083N8154 FDK:083N8165 FDK:083N8171 20“ 24“ FDK:083N8182 FDK:083N8190 FDK:083N8183 FDK:083N8191 FDK:083N8178 A5E32709738 FDK:083N8180 A5E32710253 Protection of PTFE liner use 2 pcs. Grounding of PTFE lined flowmeter use 1 pc. 3/78 Siemens FI 01 · 2016 AS2129, Table E DN Article No. DN 15 DN 25 DN 40 FDK:083N8365 FDK:083N8272 FDK:083N8280 DN 50 DN 65 DN 80 FDK:083N8281 FDK:083N8284 FDK:083N8293 DN 100 DN 125 DN 150 FDK:083N8117 FDK:083N8121 FDK:083N8128 DN 200 DN 250 DN 300 FDK:083N8134 FDK:083N8143 FDK:083N8151 DN 350 DN 400 DN 450 FDK:083N8153 FDK:083N8161 FDK:083N8176 DN 500 DN 600 FDK:083N8185 Protection of PTFE liner use 2 pcs. Grounding of PTFE lined flowmeter use 1 pcs. A5E32710253 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 3100 and MAG 3100 HT Selection and Ordering data MAG 3100 and MAG 3100 HT type E grounding and protecting ring 1 pc. Hastelloy C276 grounding and protection ring type E for PTFE liners incl. straps and screws Type E tE DN PN 6 Article No. PN 16 Article No. DN 15 DN 25 DN 40 DN 50 DN 65 DN 80 DN 100 FDK:083N8494 FDK:083N8498 FDK:083N8503 FDK:083N8495 FDK:083N8499 FDK:083N8504 PN 40 Size Article No. ANSI Class 150 Article No. Class 300 Article No. 3 FDK:083N8487 FDK:083N8488 FDK:083N8490 ½“ 1“ 1½“ FDK:083N8487 FDK:083N8489 FDK:083N8491 FDK:083N8487 FDK:083N8489 FDK:083N8491 FDK:083N8492 FDK:083N8496 FDK:083N8500 FDK:083N8505 2“ 2½“ 3“ 4“ FDK:083N8493 FDK:083N8497 FDK:083N8501 FDK:083N8506 FDK:083N8493 FDK:083N8497 FDK:083N8502 FDK:083N8507 Selection and Ordering data MAG 3100 and MAG 3100 HT1) Grounding rings: Flat rings 1 pc. AISI 316 grounding flat ring for all liners (PTFE max. 130 ºC (266 °F)) t F = 2 mm (0.08 inch) tF DN PN 10 PN 16 PN 40 Article No. Article No. Article No. DN 15 DN 25 DN 40 Size ANSI Class 150 Article No. Class 300 Article No. A5E01191969 A5E01150880 A5E01191952 ½“ 1“ 1½“ A5E01191968 A5E01150022 A5E01191961 A5E01150378 DN 50 DN 65 DN 80 A5E01150918 A5E01191954 A5E01152876 2“ 2½“ 3“ A5E01151121 A5E01191962 A5E01152910 A5E01151194 A5E01191940 A5E01152876 DN 100 DN 125 DN 150 A5E01158875 A5E01191941 A5E01191943 A5E01159072 A5E01191956 A5E01191957 4“ 5“ 6“ A5E01159146 A5E01191963 A5E01191964 A5E01159628 A5E01191944 A5E01191946 A5E01191947 A5E01191958 A5E01191959 A5E01191960 8“ 10“ 12“ A5E01191965 A5E01191966 A5E01191967 DN 200 DN 250 DN 300 1) A5E01191951 A5E01191950 A5E01191949 A5E01153422 Also for MAG 5100 W (7ME6520 DN 40 ... 300) Siemens FI 01 · 2016 3/79 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 3100 and MAG 3100 HT Selection and Ordering data MAG 3100 and MAG 3100 HT Grounding rings : Flat rings 1 pc. Hastelloy C276 grounding flat ring for all liners (PTFE max. 130 ºC (266 °F)) t F = 2 mm (0.08 inch) tF 3 DN PN 10 PN 16 PN 40 Article No. Article No. Article No. DN 15 DN 25 DN 40 Size ANSI Class 150 Article No. A5E01191981 A5E01150882 A5E01191982 ½“ 1“ 1½“ A5E01191989 A5E01150028 A5E01191990 Class 300 Article No. A5E01150379 DN 50 DN 65 DN 80 A5E01150922 A5E01191983 A5E01152889 2“ 2½“ 3“ A5E01151124 A5E01191991 A5E01152913 A5E01151197 A5E01191971 A5E01152889 DN 100 DN 125 DN 150 A5E01158886 A5E01191973 A5E01191974 A5E01159074 A5E01191984 A5E01191985 4“ 5“ 6“ A5E01159150 A5E01191992 A5E01191993 A5E01159629 A5E01191975 A5E01191976 A5E01191977 A5E01191986 A5E01191987 A5E01191988 8“ 10“ 12“ A5E01191994 A5E01191995 A5E01191996 DN 200 DN 250 DN 300 A5E01191978 A5E01191979 A5E01191980 A5E01153424 Selection and Ordering data MAG 3100 and MAG 3100 HT Grounding rings : Flat rings 1 pc. Tantalum grounding flat ring for all liners (PTFE max. 130 ºC (266 °F)) tF = 1 mm (0.04 inch) tF DN PN 16 PN 40 Article No. Article No. DN 15 DN 25 DN 40 DN 50 DN 65 DN 80 DN 100 3/80 A5E01192005 A5E01152890 A5E01158891 Siemens FI 01 · 2016 Size ANSI Class 150 Article No. A5E01192007 A5E01150883 A5E01192008 ½“ 1“ 1½“ A5E01192010 A5E01150030 A5E01192011 A5E01150926 A5E01192009 A5E01152890 A5E01159076 2“ 2½“ 3“ 4“ A5E01151129 A5E01192012 A5E01152916 A5E01159156 Class 300 Article No. A5E01150381 A5E01151199 A5E01153427 A5E01159631 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 3100 and MAG 3100 HT ■ Dimensional drawings MAG 3100 and MAG 3100 HT sensor with compact or remote transmitter 131 (5.16) 218 (8.58) 155 (6.10) 208 (8.19) 2 x M25 3 D1 D1 A A1 M20 (½"NPT) A2 131 (5.16) B L TC TE B L D TE T C Dimensions in mm (inch) Metric DN [mm] 15 25 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 1050 1100 1200 1400 1500 1600 1800 2000 A1) [mm] 187 187 197 205 212 222 242 255 276 304 332 357 362 387 418 443 494 544 571 606 653 704 704 755 810 925 972 1025 1123 1223 A1 [mm] 341 341 351 359 366 376 396 409 430 458 486 511 516 541 572 597 648 698 725 760 807 858 858 904 964 1079 1126 1179 1277 1377 A2 [mm] 338 338 348 356 363 373 393 406 427 455 483 508 513 538 569 594 645 695 722 757 804 855 855 901 961 1076 1123 1176 1274 1374 B [mm] 59 59 82 72 72 72 85 85 85 137 157 157 270 270 310 350 320 450 556 560 630 670 670 770 792 1000 1020 1130 1250 1375 D1 [mm] 104 104 124 139 154 174 214 239 282 338 393 444 451 502 563 614 715 816 869 927 1032 1136 1136 1238 1348 1574 1672 1774 1974 2174 L2) 3) EN 1092-1-201 PN 6, 10 PN 16/ PN 16 non-PED [mm] [mm] 200 200/200 200/250 250/250 250/300 300/350 350/450 450/500 500/550 550/600 600/600 600/600 600/600 600/700 875/700 -/800 1000/800 900 1125/900 1000 1250/1000 -/-/1200 1500/1200 1400 -/1400 1500 -/1500 1600 -/1600 1800 -/1800 2000 -/2000 PN 25 [mm] 350 450 500 550 600 600 625 750 800 900 1000 1100 1300 - PN 40 [mm] 200 200 200 200 200 2724) 250 250 300 350 450 500 550 600 600 680 800 - PN 63 [mm] 276 320 323 380 420 415 480 550 600 - PN 100 [mm] 260 280 300 350 340 400 450 450 530 620 680 - ANSI 16.5 Class Class 150 300 [mm] [mm] 200 200 200 200 200 200 200 200 200 272 2724) 2724) 250 310 250 335 300 300 350 350 450 450 500 500 550 550 600 600 600 640 600 730 600 860 800 950 900 1100 1100 1400 - 1) 14.5 mm shorter with AISI terminal box (Ex and high temperature version) When grounding flanges are used, the thickness of the grounding flange must be added to the built-in length 3) Tolerances on build in length (PN 6, PN 10, PN 16, PN 25 and PN 40): DN 15 to DN 200: +0/-3 mm, DN 250 to DN 400 : +0/-5 mm, DN 450 to DN 600 : +5/-5 mm, DN 700 to DN 2000 : +10/-10 mm Tolerances on build in length (PN 63 and PN 100): All sizes: +8/-8 mm 4) Not according to ISO 13359 2) Siemens FI 01 · 2016 3/81 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 3100 and MAG 3100 HT DN 3 [mm] 15 25 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 1050 1100 1200 1400 1500 1600 1800 2000 1) 2) 3) 4) 5) 6) 7) 8) 9) L1) 2) AS 2129 E AS 4087 PN 16, 21, 35 [mm] 200 200 200 200 200 2005) 250 250 300 350 450 500 550 600 600 6006) 6007) 7008) 7508) 8008) 9008) 10008) 12006) - AWWA C-207 Class D [mm] 700 750 800 900 1000 1050 1100 1200 1400 1500 1600 1800 2000 JIS K10 JIS K20 [mm] 200 200 200 200 200 2009) 250 250 300 350 450 500 550 600 600 600 600 - [mm] 200 200 240 240 272 2729) 310 335 300 350 450 500 550 600 640 680 800 - TC3) TE3) TF3) TT3) Wgt.4) [mm] 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.6 1.6 1.6 1.6 1.6 1.6 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 3.0 3.0 3.0 3.0 [mm] 6 6 6 6 6 6 6 6 6 8 8 8 8 10 10 10 10 - [mm] 2 2 2 2 2 2 2 2 2 2 2 2 - [mm] 1 1 1 1 1 1 1 - [kg] 4 5 8 9 11 12 16 19 27 40 60 80 110 125 175 200 287 330 360 450 530 660 660 1140 1180 1600 2460 2525 2930 3665 When grounding flanges are used, the thickness of the grounding flange must be added to the built-in length Tolerances on build in length (PN 6, PN 10, PN 16, PN 25 and PN 40): DN 15 to DN 200: +0/-3 mm, DN 250 to DN 400 : +0/-5 mm, DN 450 to DN 600 : +5/-5 mm, DN 700 to DN 2000 : +10/-10 mm Tolerances on build in length (PN 63 and PN 100): All sizes: +8/-8 mm TC = Type C grounding ring, TE = Type E grounding ring (Included and factory mounted on high temperature 180 °C PTFE sensor), TF = Flat type grounding rings Weights are approx. (for PN 16) without transmitter PN 35 DN 80 = 272 mm (not according to ISO 13359) PN 35 DN 500 = 680 mm PN 35 DN 600 = 750 mm Not AS 4087 PN 21 or PN 35 Not according to ISO 13359 - not available D = Outside diameter of flange, see flange tables 3/82 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 3100 and MAG 3100 HT MAG 3100 and MAG 3100 HT sensor with compact or remote transmitter Imperial Size A1) A1 A2 B D1 L2) 3) ANSI 16.5/ASME B16.474) EN 1092-1-201 PN 6, 10 PN 16/ PN 16 non PED PN 25 PN 40 PN 63 PN 100 Class 150 Class 300 Class 600 [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] ½ 7.36 13.31 13.25 2.32 4.09 - - - 7.87 - - 7.87 7.87 - 1 7.36 13.31 13.25 2.32 4.09 - - - 7.87 - 10.24 7.87 7.87 11.02 1½ 7.76 13.70 13.64 3.23 4.88 - - - 7.87 - 11.02 7.87 7.87 12.60 2 8.07 14.01 13.95 2.83 5.47 - - - 7.87 10.87 11.81 7.87 7.87 12.99 2½ 8.35 14.29 14.23 2.83 6.06 7.87 7.87/- - 7.87 12.60 13.78 7.87 10.71 on request 12.72 13.39 10.715) 10.715) 13.78 3 8.74 14.69 14.63 2.83 6.85 7.87 7.87/- - 10.715) 4 9.53 15.47 15.41 3.35 8.43 9.84 9.84/- - 9.84 14.96 - 9.84 12.20 18.11 5 10.04 15.98 15.92 3.35 9.41 9.84 9.84/- - 9.84 16.54 - 9.84 13.10 18.90 6 10.87 16.81 16.75 5.39 11.10 11.81 11.81/- - 11.81 16.34 - 11.81 11.81 19.68 8 11.97 17.91 17.85 5.39 13.31 13.78 13.78/- 13.78 13.78 18.90 - 13.78 13.78 23.62 10 13.07 19.02 18.96 6.18 15.47 17.72 17.72/- 17.72 17.72 - - 17.72 17.72 23.62 12 14.05 20.00 19.94 6.18 17.48 19.69 19.69/- 19.69 19.69 - - 19.69 19.69 27.56 14 14.25 20.20 20.14 10.63 17.76 21.65 21.65/- 21.65 21.65 - - 21.65 21.65 - 16 15.24 21.18 21.12 10.63 19.76 23.62 23.62/- 23.62 23.62 - - 23.62 23.62 - 18 16.45 22.40 22.34 12.20 22.16 23.62 23.62/- 23.62 23.62 - - 23.62 23.62 - 20 17.44 23.39 23.33 13.78 24.17 23.62 23.62/- 24.61 26.77 - - 23.62 28.70 - 24 19.45 25.39 25.33 12.59 28.15 23.62 23.62/- 29.53 31.50 - - 23.62 33.80 - 28 21.42 27.36 27.30 17.72 32.13 27.56 34.45/27.56 31.50 - - - 31.50 - - 30 22.48 28.43 28.37 21.89 34.21 - -/- - - - - 37.41 - - 32 23.86 29.80 29.74 22.05 36.50 31.50 39.37/31.50 35.44 - - - 35.44 - - 36 25.71 31.65 31.59 24.80 40.63 35.43 44.29/35.43 39.38 - - - 43.32 - - 40 27.72 33.85 33.79 26.38 44.72 39.37 49.21/39.37 43.32 - - - 43.32 - - 42 27.72 33.85 33.79 26.38 44.72 - -/- - - - - - - - 44 29.72 35.67 35.61 30.31 48.74 - -/- - - - - - - - 48 31.89 37.83 37.77 31.18 53.07 47.24 59.06/47.24 51.19 - - - 55.12 - - 54 36.42 42.36 42.30 39.37 61.97 55.12 -/55.12 - - - - - - - 60 38.27 44.21 44.15 40.15 65.83 59.06 59.06/59.06 - - - - - - - 66 40.35 46.30 46.24 44.49 69.84 62.99 -/62.99 - - - - - - - 72 44.21 50.16 50.10 49.21 77.72 70.87 -/70.87 - - - - - - - 78 48.15 54.09 54.03 54.13 85.59 78.74 -/78.74 - - - - - - - 1) 2) 3) 4) 5) 0.571 inch shorter with AISI terminal box (Ex and high temperature version) When grounding flanges are used, the thickness of the grounding flange must be added to the built-in length Tolerances on build in length (PN 6, PN 10, PN 16, PN 25 and PN 40): ½" to 8": +0/-0.12", 10" to DN 16" : +0/-0.20", 18" to DN 24" : +0.20/-0.20", 28" to DN 78" : +0.39/-0.39" Tolerances on build in length (PN 63 and PN 100): All sizes: +0.31/-0.31" ANSI 16.5 for DN 24"; ASME B16.47 for DN 28" Not according to ISO 13359 Siemens FI 01 · 2016 3/83 3 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 3100 and MAG 3100 HT Size 3 L1) 2) TC3) TE3) TF3) TT3) Weight4) AS 2129 E AS 4087 PN 16, 21, 35 AWWA C-207 Class D JIS K10 JIS K20 [in.] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [inch] [lb] ½ 7.87 - 7.87 7.87 - 0.24 0.08 0.04 9 1 7.87 - 7.87 7.87 0.05 0.24 0.08 0.04 11 1½ 7.87 - 7.87 9.44 0.05 0.24 0.08 0.04 17 2 7.87 - 7.87 9.44 0.05 0.24 0.08 0.04 20 2½ 7.87 - 7.87 10.70 0.05 0.24 0.08 0.04 24 3 7.875) - 7.878) 10.709) 0.05 0.24 0.08 0.04 26 4 9.84 - 9.84 12.20 0.05 0.24 0.08 0.04 35 5 9.84 - 9.84 13.18 0.05 0.24 0.08 - 42 6 11.81 - 11.81 11.81 0.05 0.24 0.08 - 60 8 13.78 - 13.77 13.77 0.05 0.31 0.08 - 88 10 17.72 - 17.71 17.71 0.05 0.31 0.08 - 132 12 19.69 - 19.68 19.68 0.06 0.31 0.08 - 176 14 21.65 - 21.65 21.65 0.06 0.31 - - 242 16 23.62 - 23.62 23.62 0.06 0.39 - - 275 18 23.62 - 23.62 25.19 0.06 0.39 - - 385 20 23.626) - 23.62 26.77 0.06 0.39 - - 440 24 23.627) - 23.62 31.49 0.06 0.39 - - 633 28 27.568) 27.56 - - 0.08 - - - 728 30 29.538) 29.52 - - 0.08 - - - 794 32 31.508) 31.50 - - 0.08 - - - 992 36 35.438) 35.43 - - 0.08 - - - 1168 40 39.378) 39.37 - - 0.08 - - - 1455 42 - 39.37 - - 0.08 - - - 1455 44 - 43.31 - - 0.08 - - - 2513 48 47.248) 47.24 - - 0.08 - - - 2601 54 - 55.12 - - 0.12 - - - 3528 60 - 59.06 - - 0.12 - - - 5423 66 - 63.00 - - 0.12 - - - 5566 72 - 70.87 - - 0.12 - - - 6460 78 - 78.74 - - 0.12 - - - 8080 1) 2) 3) 4) 5) 6) 7) 8) 9) When grounding flanges are used, the thickness of the grounding flange must be added to the built-in length Tolerances on build in length (PN 6, PN 10, PN 16, PN 25 and PN 40): ½" to 8": +0/-0.12", 10" to DN 16" : +0/-0.20", 18" to DN 24" : +0.20/-0.20", 28" to DN 78" : +0.39/-0.39" Tolerances on build in length (PN 63 and PN 100): All sizes: +0.31/-0.31" TC = Type C grounding ring, TE = Type E grounding ring (Included and factory mounted on high temperature 356 °F PTFE sensor), TF = Flat type grounding rings Weights are for ANSI 150 without transmitter PN 35 DN 80 = 10.70 inch PN 35 DN 500 = 26.77 inch PN 35 DN 600 = 29.53 inch Not AS 4087 PN 21 or PN 35 Not according to ISO 13359 - not available D = Outside diameter of flange, see flange tables 3/84 Siemens FI 01 · 2016