ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: Thin Film SlimLine Product #: 494xxx Series Issue Date: November 29, 2011 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued by: <Global EHS Engineer> (1) Parts, sub-materials and unit parts This document covers the Thin Film SlimLine RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identified in table 1 Remarks: January 5, 2006 Littelfuse, Inc. Page 1 Table 1: List of Raw Materials covered by this report Total Parts 1 2 3 4 5 6 January 5, 2006 Raw Material Part Number 039613/039611 010104 010113 010114 090317 090363 Littelfuse, Inc. Raw Material Description FR-4 Nickel Anode Tin Anode Copper Anode Soldermask-White Soldermask Green Page(s) 3-11 12-16 17-21 22-26 27-35 36-44 Page 1 Test Report Applicant: Number : TWNC00226907 Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Oct 11, 2011 Sample Description: One (1) group of submitted samples said to be : Part Description : FR-4 (PGB/ TFF Non-HF) Copper Clad Laminate Part Number : 039611,039612,039613,039608,039609,039610,039618 Date Sample Received : Oct 04, 2011 Date Test Started : Oct 05, 2011 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00226907 Test Conducted (Ⅰ) Test Result Summary : Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) Result (ppm) Submitted Samples ND ND ND 1 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 8084 ND Page 2 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00226907 Test Conducted (Ⅰ) Test Result Summary : Test Item Result (ppm) Submitted Samples Phthalates Di(2-ethylhexyl) Phthalate (DEHP) Dibutyl Phthalate (DBP) Benzyl Butyl Phthalate (BBP) Others Hexabromocyclododecane (HBCDD) ND ND ND ND Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Test Period : Oct 04, 2011 : Oct 05, 2011 To Oct 11, 2011 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 3 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00226907 Test Conducted (Ⅲ) Test Method: Test Item Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Cadmium (Cd) content microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Lead (Pb) content microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave Mercury (Hg) content digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition Chromium VI (Cr6+) 1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis content spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent Polybrominated extraction and determined by GC-MSD Biphenyls (PBBs) and further HPLC confirmation when necessary. With reference to IEC 62321 edition Polybrominated 1.0:2008 in annex A, by solvent extraction and determined by GC-MSD Diphenyl Ethers (PBDEs) and further HPLC confirmation when necessary. With reference to EN 14582:2007 by Halogen Content calorimetric bomb with oxygen and determined by ion chromatography With reference to EN 14372: 2004, by Phthalates solvent extraction and determined by GC-MSD With reference to USEPA 3540C, by Hexabromocyclododecane solvent extraction and determined by (HBCDD) GC-MSD Reporting Limit 2 ppm 2 ppm 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm 50 ppm 10 ppm Remark: Reporting limit = Quantitation limit of analyte in sample Page 4 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00226907 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sample preparation For non-metal part For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Weigh sample and add organic solvent By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Analyzed by ICP-OES Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List of Appropriate Acid: Material Polymers Metals Electronics Acid Added for Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 5 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00226907 Test Conducted (Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography Page 6 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00226907 Test Conducted (Ⅳ) Measurement Flowchart: Test For Phthalates Contents Reference Method: EN 14372: 2004 Sampling/grinding or cutting Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Page 7 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00226907 Test Conducted (Ⅳ) Measurement Flowchart: Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C Sampling/grinding or cutting Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD End of Report Page 8 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00226907 Test Conducted Photo Page 9 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Test Report Applicant: Number : TWNC00233062 Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Nov 23, 2011 Sample Description: One (1) group of submitted samples said to be : Part Description : Nickel Anode Part Number : 010104 Date Sample Received : Nov 17, 2011 Date Test Started : Nov 18, 2011 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233062 Test Conducted (Ⅰ) Test Result Summary : Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content (mg/kg with 50cm2) Result (ppm) Silvery Metal ND ND ND Negative (< 0.02)(#) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected < = Less than mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of Test. # = Due to the insufficient sample area, reduced total sample surface of 10 cm2 was used and the dilution factor was adjusted accordingly. Responsibility of Chemist : Irene Chiou / Kevin Liu Date Sample Received Test Period : Nov 17, 2011 : Nov 18, 2011 To Nov 22, 2011 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 2 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233062 Test Conducted (Ⅲ) Test Method: Test Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis spectrophotometer. Reporting Limit 2 ppm 2 ppm 2 ppm 0.02 mg/kg with 50cm2 Remark: Reporting limit = Quantitation limit of analyte in sample Page 3 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233062 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sample preparation Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water 6+ *2 Weigh sample and add alkaline solution Get 50cm2 sample Definite temp. extraction By boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Analyzed by UV-VIS Remarks: *1: List of Appropriate Acid: Acid Added for Digestion Material Polymers HNO3,HCl,HF,H2O2,H3BO3 Metals HNO3,HCl,HF Electronics HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report Page 4 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233062 Test Conducted Photo Page 5 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233063 Test Report Applicant: Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Nov 23, 2011 Sample Description: One (1) group of submitted samples said to be : Part Description : Tin Anode Part Number : 010113 Date Sample Received : Nov 17, 2011 Date Test Started : Nov 18, 2011 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233063 Test Conducted (Ⅰ) Test Result Summary : Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content (mg/kg with 50cm2) Result (ppm) Silvery Metal ND 50 ND Negative (< 0.02)(#) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected < = Less than mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of Test. # = Due to the insufficient sample area, reduced total sample surface of 10 cm2 was used and the dilution factor was adjusted accordingly. Responsibility of Chemist : Irene Chiou / Kevin Liu Date Sample Received Test Period : Nov 17, 2011 : Nov 18, 2011 To Nov 22, 2011 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 2 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233063 Test Conducted (Ⅲ) Test Method: Test Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis spectrophotometer. Reporting Limit 2 ppm 2 ppm 2 ppm 0.02 mg/kg with 50cm2 Remark: Reporting limit = Quantitation limit of analyte in sample Page 3 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233063 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sample preparation Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water 6+ *2 Weigh sample and add alkaline solution Get 50cm2 sample Definite temp. extraction By boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Remarks: *1: List of Appropriate Acid: Material Polymers Metals Electronics Analyzed by UV-VIS Acid Added for Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report Page 4 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233063 Test Conducted Photo Page 5 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233061 Test Report Applicant: Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Nov 23, 2011 Sample Description: One (1) group of submitted samples said to be : Part Description : Copper Anode Part Number : 010114 Date Sample Received : Nov 17, 2011 Date Test Started : Nov 18, 2011 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233061 Test Conducted (Ⅰ) Test Result Summary : Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content (mg/kg with 50cm2) Result (ppm) Coppery Metal ND ND ND Negative (< 0.02)(#) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected < = Less than mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of Test. # = Due to the insufficient sample area, reduced total sample surface of 10 cm2 was used and the dilution factor was adjusted accordingly. Responsibility of Chemist : Irene Chiou / Kevin Liu Date Sample Received Test Period : Nov 17, 2011 : Nov 18, 2011 To Nov 22, 2011 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 2 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233061 Test Conducted (Ⅲ) Test Method: Test Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis spectrophotometer. Reporting Limit 2 ppm 2 ppm 2 ppm 0.02 mg/kg with 50cm2 Remark: Reporting limit = Quantitation limit of analyte in sample Page 3 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233061 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sample preparation Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water 6+ *2 Weigh sample and add alkaline solution Get 50cm2 sample Definite temp. extraction By boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenyl-carbazide solution Remarks: *1: List of Appropriate Acid: Material Polymers Metals Electronics Analyzed by UV-VIS Acid Added for Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report Page 4 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233061 Test Conducted Photo Page 5 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Test Report Applicant: Number : TWNC00233066 Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Nov 28, 2011 Sample Description: One (1) group of submitted samples said to be : Part Description : Photoimageable solder mask white Part Number : 090317 Date Sample Received : Nov 17, 2011 Date Test Started : Nov 18, 2011 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233066 Test Conducted (Ⅰ) Test Result Summary : Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) Phthalates Di(2-ethylhexyl) Phthalate (DEHP) Dibutyl Phthalate (DBP) Benzyl Butyl Phthalate (BBP) Others Hexabromocyclododecane (HBCDD) Result (ppm) White Paste ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 301 ND ND ND ND ND ND Remarks: ppm = Parts per million based on wet weight of tested sample = mg/kg ND = Not detected Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received : Nov 17, 2011 Test Period : Nov 18, 2011 To Nov 23, 2011 Page 2 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233066 Test Conducted (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. (Ⅲ) Test Method: Test Item Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Cadmium (Cd) content microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Lead (Pb) content microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave Mercury (Hg) content digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition Chromium VI (Cr6+) 1.0:2008 in annex C, by alkaline content digestion and determined by UV-Vis spectrophotometer. Reporting Limit 2 ppm 2 ppm 2 ppm 1 ppm Page 3 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233066 Test Conducted (Ⅲ) Test Method: Test Item Test Method With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent Polybrominated extraction and determined by GC-MSD Biphenyls (PBBs) and further HPLC confirmation when necessary. With reference to IEC 62321 edition Polybrominated 1.0:2008 in annex A, by solvent Diphenyl Ethers extraction and determined by GC-MSD and further HPLC confirmation when (PBDEs) necessary. With reference to EN 14582:2007 by Halogen Content calorimetric bomb with oxygen and determined by ion chromatography With reference to EN 14372: 2004, by Phthalates solvent extraction and determined by GC-MSD With reference to USEPA 3540C, by Hexabromocyclododecane solvent extraction and determined by (HBCDD) GC-MSD Reporting Limit 5 ppm 5 ppm 50 ppm 50 ppm 10 ppm Remark: Reporting limit = Quantitation limit of analyte in sample Page 4 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233066 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sample preparation For non-metal part For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Weigh sample and add organic solvent By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Analyzed by ICP-OES Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List of Appropriate Acid: Acid Added for Digestion Material Polymers HNO3,HCl,HF,H2O2,H3BO3 Metals HNO3,HCl,HF Electronics HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 5 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233066 Test Conducted (Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography Page 6 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233066 Test Conducted (Ⅳ) Measurement Flowchart: Test For Phthalates Contents Reference Method: EN 14372: 2004 Sampling/grinding or cutting Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Page 7 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233066 Test Conducted (Ⅳ) Measurement Flowchart: Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C Sampling/grinding or cutting Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD End of Report Page 8 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233066 Test Conducted Photo Page 9 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Test Report Applicant: Number : TWNC00233067 Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Nov 28, 2011 Sample Description: One (1) group of submitted samples said to be : Part Description : Photoimageable solder mask Green Part Number : 090363 Date Sample Received : Nov 17, 2011 Date Test Started : Nov 18, 2011 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233067 Test Conducted (Ⅰ) Test Result Summary : Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) Phthalates Di(2-ethylhexyl) Phthalate (DEHP) Dibutyl Phthalate (DBP) Benzyl Butyl Phthalate (BBP) Others Hexabromocyclododecane (HBCDD) Result (ppm) Green Paste ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND 2903 ND ND ND ND ND ND Remarks: ppm = Parts per million based on wet weight of tested sample = mg/kg ND = Not detected Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received : Nov 17, 2011 Test Period : Nov 18, 2011 To Nov 23, 2011 Page 2 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233067 Test Conducted (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. (Ⅲ) Test Method: Test Item Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Cadmium (Cd) content microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Lead (Pb) content microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave Mercury (Hg) content digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition Chromium VI (Cr6+) 1.0:2008 in annex C, by alkaline content digestion and determined by UV-Vis spectrophotometer. Reporting Limit 2 ppm 2 ppm 2 ppm 1 ppm Page 3 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233067 Test Conducted (Ⅲ) Test Method: Test Item Test Method With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent Polybrominated extraction and determined by GC-MSD Biphenyls (PBBs) and further HPLC confirmation when necessary. With reference to IEC 62321 edition Polybrominated 1.0:2008 in annex A, by solvent Diphenyl Ethers extraction and determined by GC-MSD and further HPLC confirmation when (PBDEs) necessary. With reference to EN 14582:2007 by Halogen Content calorimetric bomb with oxygen and determined by ion chromatography With reference to EN 14372: 2004, by Phthalates solvent extraction and determined by GC-MSD With reference to USEPA 3540C, by Hexabromocyclododecane solvent extraction and determined by (HBCDD) GC-MSD Reporting Limit 5 ppm 5 ppm 50 ppm 50 ppm 10 ppm Remark: Reporting limit = Quantitation limit of analyte in sample Page 4 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233067 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sample preparation For non-metal part For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Weigh sample and add organic solvent By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Analyzed by ICP-OES Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List of Appropriate Acid: Acid Added for Digestion Material Polymers HNO3,HCl,HF,H2O2,H3BO3 Metals HNO3,HCl,HF Electronics HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 5 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233067 Test Conducted (Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the flask at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography Page 6 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233067 Test Conducted (Ⅳ) Measurement Flowchart: Test For Phthalates Contents Reference Method: EN 14372: 2004 Sampling/grinding or cutting Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Page 7 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233067 Test Conducted (Ⅳ) Measurement Flowchart: Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C Sampling/grinding or cutting Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD End of Report Page 8 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00233067 Test Conducted Photo Page 9 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401