Low-Voltage Motors SIMOTICS XP: Type series 1MD5 LOHER CHEMSTAR: Type series 1PS0, 1PS1, 1PS5 LOHER VARIO: Type series 1PS0, 1PS1, 1PS4, 1PS5 Price List 2015 (Version a) SIMOTICS XP Ex d; Ex de; Frame sizes 71 to 355; Power range 0,25 to 460kW LOHER CHEMSTAR non Ex; Ex nA; Ex d; Ex de; Frame sizes 71 to 355; Power range 0,12 to 460kW LOHER VARIO non Ex; Ex nA; Ex d; Ex de; Frame sizes 355 to 500; Power range 90 to 1400kW Standard Motors Brake Motors Ex-Motors Ex-Brake Motors Water jacket cooled Motors Table of contents Page General .................................................................................................................................................................................................................. 2 Order number configuration (MLFB) …………………..………………………………….…………………………………………………………………… 4 Derating tables ………………………………………….……………..…………………………………………………………………………………….… 8 SIMOTICS XP 1MD5 motor series ........................................................................................................................................................................ 14 SIMOTICS XP 1MD5 motor series - Article No. supplements ............................................................................................................................... 17 SIMOTICS XP 1MD5 motor series - Special versions ........................................................................................................................................... 18 LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series ........................................................................................................................... 20 LOHER CHEMSTAR 1PS5 motor series IE3 ....................................................................................................................................................... 36 LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series - Article No. supplements ................................................................................. 40 LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series - Special versions ............................................................................................. 42 LOHER CHEMSTAR and VARIO 1PS1 motor series ........................................................................................................................................... 49 LOHER CHEMSTAR 1PS1 motor series IE3 ....................................................................................................................................................... 55 LOHER CHEMSTAR and VARIO 1PS1 motor series - Article No. supplements .................................................................................................. 58 LOHER CHEMSTAR and VARIO 1PS1 motor series - Special versions .............................................................................................................. 60 LOHER CHEMSTAR and VARIO 1PS0 motor series ........................................................................................................................................... 67 LOHER CHEMSTAR 1PS0 motor series IE3 ....................................................................................................................................................... 83 LOHER CHEMSTAR and VARIO 1PS0 motor series - Article No. supplements .................................................................................................. 87 LOHER CHEMSTAR and VARIO 1PS0 motor series - Special versions .............................................................................................................. 89 Documentation for Motors 1PS0, 1PS1, 1PS4 and 1PS5 ………………………………………………………………………………………………… 96 Tests and witnessed tests for 1PS0, 1PS1, 1PS4 und 1PS5 motors ……………………………………………………………………………………… 98 Test fees for 1PS0, 1PS1, 1PS4 und 1PS5 motors ………………………………………………………………………………………………………… 99 Freight charges ………………………………………………………………………………………………………………………………………………… 100 Terms an Conditions for Deliveries and Services for Siemens Internal Transactions ……………………………………………………………………101 Phone numbers of service, repair and spare parts departments ........................................................................................................................... 109 Three-phase motors in other special designs (e.g. ship and marine motors) on request. Lower and higher outputs, other combinations of numbers of poles as well as voltages, frequencies and designs on request. Note: Technical data are indicated in the current catalogue D 83.1 Overview discount levels: GCK P114 P114 P114 P132 Price group 3L2 3L1 3L0 6LG Price group text IM-LOHER Non-Ex-motors IM-LOHER Ex-motors IM-SIMOTICS XP - 1MD5 TM-LOHER low voltage motors MLFB group 1PS0 1PS1 / 1PS5 1MD5 1PS4 / 1PS5 FAGR / PCK 2241 2240 2242 5786 Motor series LOHER CHEMSTAR LOHER CHEMSTAR SIMOTICS XP LOHER VARIO The prices are recommended without obligation. In case of conflicts the data of PMD are binding ! Discount level A A B C General Conditions of Sale and Delivery Supplements for Freight and Packing for Domestic and Export Sales In case of orders the following freight and packing supplements The general conditions of sale and delivery, as printed on the pages will be invoiced. 101 to 108, are applicable. The gross prices stated in EURO ( €) are for delivery EX works Ruhstorf (acc. To INCOTERMS 2010), Order value in EUR Supplement without packing, and without VAT. % The prices are recommended without obligation. up to 500 10 In connection with this price list new conditions are applicable. up to 2.500 8 Prices are subject to alterations without notice. The prices valid over 2.500 5 on the day of delivery are taken as basis for invoicing. Minimum order value Euro 500,-. Subject to delivery opportunities and technical modifications. Delivery Obligation for Replacement Motors and for Spare Parts upon Delivery of the Motor Actual delivery times for motors and for documentation can be checked up to 5 years with our headquarters. All delivery times given are valid from the date a clarified order has been received, and are considered for delivery ex works. Loher delivers in case of a total motor failure - a comparable motor (changeover of series is possible) - as to the mounting dimensions and function up to 5 years up to 10 yrs. spare parts can be delivered. Loher will give information and delivers, if needed, documents for specific repair parts. Copper Price Supplements The valid prices remain unchanged up to a DEL-notice of EUR 225.every 100 kg. Above EUR 225.- every 100 kg the following Export Regulations percentage increases, referred to the respective net price, Products mentioned in this price list do not require an export will be charged. licence acc. to the current German and US export regulations. Thus exports or re-exports are allowed without special DEL-notice EUR every 100 kg Copper Copper supplement supplement for Ex d motors % % 225 until up 275 1,2 1 275 until up 325 2,5 1,5 325 until up 375 3,5 2 permission of the competent authorities, if no country-specific restrictions are provided by the Außenwirtschaftsverordnung (Foreign Trade and Payments Ordinance). Alterations reserved. In any case the descriptions indicated in the delivery note and invoice are prevailing. An export permit might 375 until up 425 4,5 3 become necessary due to the individual applicaction of the 425 until up 475 5,5 4 products in the specific country. 475 until up 525 6,5 5 525 until up 575 7,5 6 575 until up 625 8,5 7 625 until up 675 9,5 8 explicitly been requested and which are stated in our 675 until up 725 10,5 9 order confirmation. 725 until up 775 11,5 10 775 until up 825 12,5 11 … … … Only those features are considered being binding which have The copper supplements charged depend on the DEL-notice prevailing on the date of order receipt and delivery request respectively. Change or Cancellation For changes or cancellations the actual costs incurred will be invoiced. Depending on the order progress the following fixed charges will result (additionally to the technical modification costs). Costs in % of the order value Change Cancellation Order in technical calculation / construction Manufacturing document. issued Order in production Motor in testing % 6 % 25 10 15 20 50 80 95 Motor testing finished 25 100 For motor series 1MD5… changes of orders during production is not allowed. Changes of design have to be organised with cancelling and reorder. In such cases cost as column "cancellation" are valid. This price list is valid as of October 1, 2014 (Subject to alterations without notice) Validity period: until September 30, 2015 All previous price lists are invalid with immediate effect ! 2 General Voltages and Frequencies in general The motors in this list are available for a standard voltage according to the table mentioned below at 50-Hz mains. The usual rated voltages and the appropriate tolerances are indicated in the table below. The motors of the series 1PS… can designed with a non-standard winding with almost any frequency and mains voltage up to 1000V. The operating data according to the output tables are applicable to the indicated rated voltages and tolerances acc. to DIN EN 60 034-1. Standard Voltages and Tolerances Fixed voltage Tolerance range A ± 5% Rated Voltage voltage limit 230 V 400 V 500 V 690 V 218 V - 242 V 380 V - 420 V 475 V - 525 V 655 V - 725 V Tolerance range B ± 10% Voltage limit 207 V - 253 V 360 V - 440 V 450 V - 550 V 621 V - 759 V Tolerance Range A: Motor must be reliable in continuous duty. Temperature rise is allowed to be higher by 10 K than the limit value. Tolerance Range B: Motor must be reliable and is not allowed to differ decisively from the rating data; an operation at the limits of B during a longer period is not recommended. As standard the rated voltage with the allowed tolerance of mains of +-10% is stamped only. Remark inverter duty: To avoid bearing currents motors frame size 315 and above the option L27 (insulated bearing NDE) have to be selected. However, we recommend to use for motors frame size 250 and above with insulated bearing on the non-drive end. In addition it is obligatory to have Option A15 or A16 (PTC for sole protection) in all Ex-Motors. The winding in standard isolation is usable for peak voltage according to EN60034-25 curve A (1560V). With special isolation system the requirements according to curve B (2150V) is fulfilled. Product figures of motor series in standard design: - housing and terminal box in cast iron - fan housing of sheet steel, painted - for ambient temperature -20 to +40°C - insulation class F, utilization B (155/130°C) - altitude 1000 meter above sea level - duty S1-100% - efficiency class IE2 (from 0,75kW) according to IEC60034-30 - located bearing at drive end - terminal box on top - metric cable entry threads, sealed with Ex certified plastic plugs - standard painting - 1PS0/1 system N04 (30µm + 40µm); limited suitable for outdoor use - 1PS5 + 1MD5 system N08 (30µm + 80µm); suitable for outdoor use - colour RAL7030 Connection of auxiliaries in case of selected additional terminal box: In case of space heater or monitoring devices (e.g. PTC, PT100), the connection will be in the additional terminal box. In case of space heater and monitoring devices (e.g. PTC, PT100) in combination, the connection of monitoring will be in additional box and heater in main box. In case of two additional terminal boxes the connection will be spitted in heater and monitoring devices. In case of no extra terminal box for auxiliaries the heater as well as the monitoring devices are connected in main terminal box. This price list is valid as of October 1, 2014 (Subject to alterations without notice) Validity period: until September 30, 2015 All previous price lists are invalid with immediate effect ! 3 MLFB 1PS. and 1MD5 4 5 6 7 8 9 10 11 12 13 14 15 16 LOHER Motors : SIMOTICS XP CHEMSTAR VARIO 1 1 1 1 M D P S P S 2 3 5 . . . . . . . . . . . - . . . . . . . . . . . . . . . - . . . . . . . . . . . . 4th digit : Explosion protection 1 P . . . . - . . . . . - . . . . . . . . - . . . . . - . . . . . 0 0 0 0 1 1 1 1 1 2 2 2 2 3 3 4 4 5 5 6 7 8 9 9 9 6 7 8 9 0 1 3 6 8 0 2 5 8 1 5 0 5 0 6 3 1 0 0 1 9 . . S 1 P S . 063 mm 071 mm 080 mm 090 mm 100 mm 112 mm 132 mm 160 mm 180 mm 200 mm 225 mm 250 mm 280 mm 315 mm 355 mm 400 mm 450 mm 500 mm 560 mm 630 mm 710 mm 800 mm 900 mm 1000 mm Special shaft height, acc. to techn. requirement 7th digit : Length / development or power stage 1 P S . F . - Special length of core . . . . - . . . 1 P S . . . . - . 3 . A . G 3 A . . . . - . . . . . . . . . - . . . . . 0 1 2 3 4 5 6 7 8 Low voltage, mains-fed operation Low voltage, converter-fed operation, standard insulation Low voltage, converter-fed operation with special insulation Low voltage, mains-fed operation, pre-formed coil Low voltage, converter-fed operation, pre-formed coil Medium voltage, mains-fed operation, round wire random winding Medium voltage, mains-fed operation, pre-formed coil Medium voltage, converter-fed operation, standard insulation, pre-formed coil Medium voltage, converter-fed operation with special insulation, pre-formed coil 9th digit : Type of machine . 0 1 2 3 4 5 6 7 8 9 Power stage / length of core ascending 8th digit : Insulation . . . 0 1 2 3 4 5 6 without explosion protection, i.e. safe area II 3G Ex nA IIC T3 Gc II 2G Ex e IIC T3 Gb I M2 Ex d(e) I Mb II 2G Ex d(e) IIB T4 Gb II 2G Ex d(e) IIC T4 Gb II 2G Ex px IIC T3 Gb 5th - 6th digit : Frame size / shaft height (IEC only) Z-Option - 1 P S . . . . - . A B D E F G H J K L M N P Q R S T Asynchronous motor, squirrel cage, open design (ODP) Asynchronous motor, squirrel cage, totally enclosed (TE..) Asynchronous generator, squirrel cage, open design (ODP) Asynchronous generator, squirrel cage, totally enclosed (TE..) Asynchronous motor, slip ring rotor (wound rotor), open design (ODP) Asynchronous motor, slip ring rotor (wound rotor), totally enclosed (TE..) Asynchronous generator, slip ring rotor, open design (ODP) Asynchronous generator, slip ring rotor, totally enclosed (TE..) Fan design Fire-gas motors Elevator/lift motors Brake motor Special motors / submersible pumps Special motors / others 4 MLFB 1PS. and 1MD5 10th digit : Stator housing / Outside fan 1 2 3 4 5 6 7 1 P S . . . . - 8 9 10 11 12 13 14 15 16 . . . . . - . . . . . . . - . . . . . A B C D E F G H J K L M N P Q R S T U V W X Y St.-w. or cast iron housing, internally cooled, air/water heat exchanger, forced ventilation Aluminium housing, surface cooled, with outside fan, B-serie Cast iron housing, surface cooled, without fan Cast iron housing, surface cooled, with outside fan Cast iron housing, surface cooled, with outside fan, B-serie Cast iron housing, surface cooled, with forced fan Steel-welded housing, surface cooled, without fan, without inner fan Steel-welded housing, surface cooled, with outside fan, without inner fan Steel-welded housing, surface cooled, with outside fan, with inner fan Steel-welded housing, surface cooled, with forced fan, without inner fan Steel-welded housing, surface cooled, with forced fan, with inner fan St.-w. or cast iron housing, internally cooled, air/air heat exchanger, forced ventilation outside St.-w. or cast iron housing, internally cooled, air/air heat exchanger, forced vent. inside/outside Steel-welded or cast iron housing, internally cooled, with air/air heat exchanger Steel-welded or cast iron housing, internally cooled, with air/water heat exchanger Steel-w. or cast iron housing, internal cooling circuit, 3-fold change of flow direction Steel-welded housing, pipe cooled, with outside fan Steel-welded housing, pipe cooled, with forced fan Steel-welded or cast iron housing, open design (ODP) with internal cooling circuit Without housing Steel-welded or cast iron housing, water-jacket-cooled, with inner fan Steel-welded or cast iron housing, water-jacket-cooled, without inner fan Steel-welded, surface cooled, without fan, with inner fan 11th digit : Rated voltage / connection / frequency Z-Option 1 P S . . . . - . . . 220 V D / 380 V S, 50Hz 230 V D / 400 V S, 50Hz 415 V S, 50Hz 415 V D, 50Hz 380 V D / 660 V S, 50Hz 400 V D / 690 V S, 50Hz 690 V S, 50Hz 500 V S, 50Hz 400 V D, 50Hz 500 V D, 50Hz 690 V D, 50Hz 1000 V, 50Hz 220 V D / 380 V S, 60Hz (50Hz-output) 220 V D / 380 V S, 60Hz (60Hz-output) 380 V D / 660 V S, 60Hz (50Hz-output) 380 V D / 660 V S, 60Hz (60Hz-output) 440 V S, 60Hz (50Hz-output) 440 V S, 60Hz (60Hz-output) 440 V D, 60Hz (50Hz-output) 440 V D, 60Hz (60Hz-output) 460 V S, 60Hz (50Hz-output) 460 V S, 60Hz (60Hz-output) 460 V D, 60Hz (50Hz-output) 460 V D, 60Hz (60Hz-output) 575 V S, 60Hz (50Hz-output) 575 V S, 60Hz (60Hz-output) 575 V D, 60Hz (50Hz-output) 575 V D, 60Hz (60Hz-output) other voltages 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 1 9 9 9 6 8 3 4 5 0 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 220 V D / 380 V S, 50Hz 230 V D / 400 V S, 50Hz 415 V S, 50Hz 415 V D, 50Hz 380 V D / 660 V S, 50Hz 400 V D / 690 V S, 50Hz 690 V S, 50Hz 500 V S, 50Hz 400 V D, 50Hz 500 V D, 50Hz 690 V D, 50Hz 1000 V, 50Hz 220 V D / 380 V S, 60Hz (50Hz-output) 220 V D / 380 V S, 60Hz (60Hz-output) 380 V D / 660 V S, 60Hz (50Hz-output) 380 V D / 660 V S, 60Hz (60Hz-output) 440 V S, 60Hz (50Hz-output) 440 V S, 60Hz (60Hz-output) 440 V D, 60Hz (50Hz-output) 440 V D, 60Hz (60Hz-output) 460 V S, 60Hz (50Hz-output) 460 V S, 60Hz (60Hz-output) 460 V D, 60Hz (50Hz-output) 460 V D, 60Hz (60Hz-output) 575 V S, 60Hz (50Hz-output) 575 V S, 60Hz (60Hz-output) 575 V D, 60Hz (50Hz-output) 575 V D, 60Hz (60Hz-output) other voltages 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 9 1 9 9 9 6 8 3 4 5 0 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 5 L 1 R L L L 1 1 1 C D L L L L L L L L L L L L L L L L L L L 1 V 2 A 2 B 2 C 2 D 2 Q 2 W 2 R 2 X 2 S 2 E 2 T 2 F 2 U 2 L 2 V 2 M 1 Y L 1 R L L L 1 1 1 C D L L L L L L L L L L L L L L L L L L L 1 V 2 A 2 B 2 C 2 D 2 Q 2 W 2 R 2 X 2 S 2 E 2 T 2 F 2 U 2 L 2 V 2 M 1 Y MLFB 1PS. and 1MD5 11th digit : Rated voltage / connection / frequency 1 2 3 4 5 6 7 1 P S . . . . - 8 9 10 11 12 . . . . . - 13 14 15 16 . . . . Z-Option . 380 V D / 660 V S, 50Hz 400 V D / 690 V S, 50Hz 690 V S, 50Hz 400 V D, 50Hz 500 V D, 50Hz 690 V D, 50Hz 1000 V, 50Hz 380 V D / 660 V S, 60Hz (50Hz-output) 380 V D / 660 V S, 60Hz (60Hz-output) 575 V S, 60Hz (50Hz-output) 575 V S, 60Hz (60Hz-output) 575 V D, 60Hz (50Hz-output) 575 V D, 60Hz (60Hz-output) other voltages 2 2 2 2 2 2 2 2 2 2 2 2 2 2 9 6 8 4 5 0 9 9 9 9 9 9 9 9 L 1 L L L L L L L L L 1 2 2 2 2 2 2 1 V C D U L V M Y 400 V D / 690 V S, 50Hz 500 V S, 50Hz 690 V S, 50Hz 500 V D, 50Hz 690 V D, 50Hz 1000 V D, 50Hz other voltages 3 3 3 3 3 3 3 6 3 8 5 0 9 9 L L 1 1 V Y 3kV, 50Hz 3,3kV, 50Hz 4,16kV, 50Hz 2,3kV, 60Hz 3,3kV, 60Hz 4kV, 60Hz 4,16kV, 60Hz other voltages 5 5 5 5 5 5 5 5 3 0 9 9 9 4 9 9 L L L 6 6 6 S L M L L 6 6 N Y 3kV, 50Hz 3,3kV, 50Hz 4,16kV, 50Hz 5,5kV, 50Hz 6kV, 50Hz 6,3kV, 50Hz 6,6kV, 50Hz 10kV, 50Hz 11kV, 50Hz 2,3kV, 60Hz 3,3kV, 60Hz 4kV, 60Hz 4,16kV, 60Hz 6,6kV, 60Hz 11kV, 60Hz other voltages 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 3 0 9 9 6 9 7 8 9 9 9 4 9 1 9 9 L L 6 6 S R L 6 Q L L L 6 6 6 K L M L 6 N L L 6 6 P Y 3kV, 50Hz 3,3kV, 50Hz 4,16kV, 50Hz 5,5kV, 50Hz 6kV, 50Hz 6,3kV, 50Hz 6,6kV, 50Hz 10kV, 50Hz 11kV, 50Hz 2,3kV, 60Hz 3,3kV, 60Hz 4kV, 60Hz 4,16kV, 60Hz 6,6kV, 60Hz 11kV, 60Hz other voltages 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 3 0 9 9 6 9 7 8 9 9 9 4 9 1 9 9 L L 6 6 S R L 6 Q L L L 6 6 6 K L M L 6 N L L 6 6 P Y 3kV, 50Hz 3,3kV, 50Hz 4,16kV, 50Hz 5,5kV, 50Hz 6kV, 50Hz 6,3kV, 50Hz 6,6kV, 50Hz 2,3kV, 60Hz 3,3kV, 60Hz 4kV, 60Hz 4,16kV, 60Hz 6,6kV, 60Hz other voltages 8 8 8 8 8 8 8 8 8 8 8 8 8 3 0 9 9 6 9 7 9 9 4 9 1 9 L L 6 6 S R L 6 Q L L 6 6 L M L 6 N L 6 Y 6 MLFB 1PS. and 1MD5 12th digit : Mounting arrangement 1 2 3 4 5 6 7 1 P S . . . . - 8 9 10 11 12 . . . . . IM B 35 IM V 1, without canopy IM B 6 IM B 7 IM B 8 IM V 5, without canopy IM V 6 IM V 5, with canopy IM V 3 IM V 36 IM V 8, without canopy IM V 8, with canopy IM V 19 IM B 20 IM B 5, with additional fixing point IM V 15, with canopy IM V 15, without canopy IM V 18, with canopy IM V 18, without canopy IM B 2 IM A 4 IM B 9 IM V 10, with canopy IM V 10, without canopy IM B 17 without housing other mounting arrangement 1 P S without temperature class Temperature class T1 (max. surface temperature 450°C/842°F) Temperature class T2 (max. surface temperature 300°C/572°F) Temperature class T3 (max. surface temperature 200°C/392°F) Temperature class T4 (max. surface temperature 135°C/275°F) Temperature class T5 (max. surface temperature 100°C/212°F) Temperature class T6 (max. surface temperature 80°C/176°F) 14th: Number of poles 13 14 15 16 . . . . 0 1 2 3 4 5 6 7 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 IM B 3 IM B 5 IM B 34 IM B 14 IM V 1, with canopy 13th digit : Temperature class (for explosion protection) - . . . . - . . . . . P S - . . . . . . . . . - . . . . . - . . . . . A B C D E F G H J K L M N P Q R S T U V W X Y Z 4/2 poles 6/4 poles 8/4 poles 8/6 poles 8/6/4 poles 16/4 poles other numbers of poles 1 P S . . . . - . . . . . - . . P . 3 Y . . . . A B C D E F G H Antifriction bearings / standard rotor Antifriction bearings / special rotor Antifriction bearings for extended speed range, rotor for inverter-fed operation Sleeve bearings / standard rotor Sleeve bearings / special rotor Sleeve bearings for extended speed range, rotor for inverter-fed operation Antifriction bearings / standard rotor, IE1 Antifriction bearings / standard rotor, IE3 16th digit : Developmental stage 1 A 1 B 1 C 1 D 1 E 1 F 1 G 1 H 1 J 1 K 1 L 1 M 1 P 1 Q 2 J 2 K 2 L 2 M 2 N 2 P 2 Q 2 R 2 S 2 T 2 U 2 V 2 Y 0 1 2 3 4 5 6 2 poles 4 poles 6 poles 8 poles 10 poles 12 poles 14 poles 16 poles 18 poles 20 poles 15th digit : Type of bearings / Type of rotor . M M M M M M M M M M M M M M M M M M M M M M M M M M M 0 1 Z-Option 1 P S . . . . - . . . . . - . . . 0 1 2 3 New generation (actual for J-motors FS500 and FS560) Efficiency class IE2 Re-Design 7 1PS0 and 1PS1 motors Derating tables for increased ambient temperatures and site altitudes Rated output for Rated output for standard version ambient temperature and site altitude +40 °C, 1000 m +45 °C, 1000 m +50 °C, 1000 m +55 °C, 1000 m D11 D12 D13 +40 °C, 1500 m +45 °C, 1500 m +50 °C, 1500 m D06 D11+D06 D12+D06 +40 °C, 2000 m +45 °C, 2000 m D07 D11+D07 Additional identification code -Z with appropriate order codes +40 °C, 2500 m D08 Winding utilization 130°C (B) Type Motor type IE class Prated kW Padm kW Padm kW Padm kW 1PS0 and 1PS1 motors - 2-pole 1PS.095-.BD..-.AA3 ANG.-090LR-02 IE2 1,5 1,5 1,5 1,5 1PS.098-.BD..-.AA3 ANG.-090LS-02 IE2 2,2 2,2 2,2 2,2 3 1PS.106-.BD..-.AA3 ANG.-100LS-02 IE2 3 3 3 1PS.113-.BD..-.AA3 ANG.-112MS-02 IE2 4 4 4 4 1PS.131-.BD..-.AA3 ANG.-132SR-02 IE2 5,5 5,5 5,5 5,5 1PS.132-.BD..-.AA3 ANG.-132SS-02 IE2 7,5 7,5 7,5 7,5 1PS.163-.BD..-.AA3 ANG.-160MR-02 IE2 11 11 11 11 1PS.165-.BD..-.AA3 ANG.-160MS-02 IE2 15 15 15 15 1PS.166-.BD..-.AA3 ANG.-160LS-02 IE2 18,5 18,5 18,5 18,5 1PS.183-.BD..-.AA3 ANG.-180MS-02 IE2 22 22 22 22 1PS.206-.BD..-.AA3 ANG.-200LR-02 IE2 30 30 30 30 37 1PS.208-.BD..-.AA3 ANG.-200LS-02 IE2 37 37 37 1PS.223-.BD..-.AA3 ANG.-225MS-02 IE2 45 45 45 45 1PS.253-.BD..-.AA3 ANG.-250MM-02 IE2 55 55 55 50 1PS.280-.BD..-.AA3 ANG.-280SL-02 IE2 75 75 75 75 1PS.283-.BD..-.AA3 ANG.-280MM-02 IE2 90 90 90 90 1PS.311-.BD..-.AA3 ANG.-315SL-02 IE2 110 110 110 1PS.313-.BD..-.AA3 ANG.-315ML-02 IE2 132 132 120 1) 110 110 1) 1) 135 1) 170 1) 1PS.315-.BD..-.AA3 ANG.-315MN-02 IE2 160 160 145 1PS.316-.BD..-.AA3 ANG.-315LL-02 IE2 200 190 1) 180 1) 1) 1) 230 210 1) 1PS.318-.BD..-.AA3 ANG.-315LN-02 IE2 250 240 1PS.356-.BD..-.AA2 ANG.-355LB-02 IE2 315 300 290 275 1PS.357-.BH..-.AA0 ANS.-355LC-02 IE2 355 340 325 310 1PS.358-.BH..-.AA0 ANS.-355LD-02 2) 400 380 365 350 1PS.358-.BJ..-.AA0 ANS.-355LX-02 2) 450 430 410 395 1PS.404-.BJ..-.AA0 ANS.-400LL-02 2) 450 430 410 395 1PS.405-.BJ..-.AA0 ANS.-400LN-02 2) 500 480 460 440 1PS.407-.BJ..-.AA0 ANS.-400LN-02 2) 560 535 515 490 1PS.408-.BJ..-.AA0 ANS.-400LX-02 2) 630 605 580 550 1PS.453-.BJ..-.AA0 ANS.-450LL-02 2) 630 605 580 550 1PS.455-.BJ..-.AA0 ANS.-450LL-02 2) 710 680 650 625 1PS.457-.BJ..-.AA0 ANS.-450LN-02 2) 800 765 735 700 1PS.458-.BJ..-.AA0 ANS.-450LN-02 2) 900 860 825 790 1PS.507-.BJ..-.AA0 ANS.-500LL-02 2) 1000 960 920 880 1PS.508-.BJ..-.AA0 ANS.-500LN-02 2) 1200 1150 1100 1055 1) 2) Alternative combination with Option C29 "Rated output of the lower output level". Please inquire regarding higher ambient temperatures and other combinations. Outside the IE code classification according to IEC 60034-30. 8 1PS0 and 1PS1 motors Derating tables for increased ambient temperatures and site altitudes Rated output for Rated output for standard version ambient temperature and site altitude +40 °C, 1000 m +45 °C, 1000 m +50 °C, 1000 m +55 °C, 1000 m D11 D12 D13 +40 °C, 1500 m +45 °C, 1500 m +50 °C, 1500 m D06 D11+D06 D12+D06 +40 °C, 2000 m +45 °C, 2000 m D07 D11+D07 Additional identification code -Z with appropriate order codes +40 °C, 2500 m D08 Winding utilization 130°C (B) Type Motor type IE class Prated kW Padm kW Padm kW Padm kW 1PS0 and 1PS1 motors - 4-pole 1PS.095-.BD..-.BA3 ANG.-090LR-04 IE2 1,1 1,1 1,1 1,1 1PS.098-.BD..-.BA3 ANG.-090LS-04 IE2 1,5 1,5 1,5 1,5 2,2 1PS.106-.BD..-.BA3 ANG.-100LR-04 IE2 2,2 2,2 2,2 1PS.108-.BD..-.BA3 ANG.-100LS-04 IE2 3 3 3 3 1PS.113-.BD..-.BA3 ANG.-112MS-04 IE2 4 4 4 4 1PS.131-.BD..-.BA3 ANG.-132SR-04 IE2 5,5 5,5 5,5 5,5 1PS.133-.BD..-.BA3 ANG.-132MS-04 IE2 7,5 7,5 7,5 7,5 1PS.163-.BD..-.BA3 ANG.-160MR-04 IE2 11 11 11 11 1PS.166-.BD..-.BA3 ANG.-160LS-04 IE2 15 15 15 15 1PS.183-.BD..-.BA3 ANG.-180MR-04 IE2 18,5 18,5 18,5 18,5 1PS.186-.BD..-.BA3 ANG.-180LS-04 IE2 22 22 22 22 30 1PS.206-.BD..-.BA3 ANG.-200LS-04 IE2 30 30 30 1PS.220-.BD..-.BA3 ANG.-225SR-04 IE2 37 37 37 37 1PS.223-.BD..-.BA3 ANG.-225MS-04 IE2 45 45 45 45 1PS.253-.BD..-.BA3 ANG.-250MM-04 IE2 55 55 55 50 1PS.280-.BD..-.BA3 ANG.-280SL-04 IE2 75 75 75 75 1PS.283-.BD..-.BA3 ANG.-280MM-04 IE2 90 90 90 90 1PS.311-.BD..-.BA3 ANG.-315SL-04 IE2 110 110 110 100 1PS.313-.BD..-.BA3 ANG.-315ML-04 IE2 132 132 132 120 1) 1PS.315-.BD..-.BA3 ANG.-315MN-04 IE2 160 160 145 1) 135 1) 1) 170 1) 1) 180 1) 1PS.316-.BD..-.BA3 ANG.-315LL-04 IE2 200 190 1PS.317-.BD..-.BA3 ANG.-315LM-04 IE2 250 240 1) 230 1) 210 1) 1PS.356-.BD..-.BA2 ANG.-355LB-04 IE2 280 265 1) 255 1) 240 1) 1) 1) 275 1) 290 1PS.356-.BD..-.BB2 ANG.-355LB-04 IE2 315 300 1PS.358-.BH..-.BA0 ANS.-355LC-04 IE2 355 340 1) 325 1) 310 1) 1PS.350-.BH..-.BA0 ANS.-355LD-04 2) 400 380 1) 365 1) 350 1) 1PS.357-.BJ..-.BA0 ANS.-355LN-04 2) 450 430 1) 1) 395 1) 1PS.358-.BJ..-.BA0 ANS.-355LX-04 2) 500 480 1) 460 1) 440 1) ANS.-400LL-04 2) 500 480 1) 460 1) 440 1) 1PS.405-.BJ..-.BA0 ANS.-400LN-04 2) 560 535 1) 515 1) 490 1) 1PS.407-.BJ..-.BA0 ANS.-400LN-04 2) 630 600 1) 580 1) 550 1) ANS.-400LX-04 2) 710 680 1) 1) 620 1) 1PS.455-.BJ..-.BA0 ANS.-450LL-04 2) 800 765 1) 735 1) 700 1) 1PS.457-.BJ..-.BA0 ANS.-450LN-04 2) 900 860 1) 825 1) 790 1) 1PS.458-.BJ..-.BA0 ANS.-450LN-04 2) 950 910 1) 1) 835 1) 1PS.504-.BJ..-.BA0 ANS.-500LL-04 2) 1000 960 1) 920 1) 880 1) 1PS.505-.BJ..-.BA0 ANS.-500LL-04 2) 1120 1075 1) 1PS.507-.BJ..-.BA0 ANS.-500LN-04 2) 1250 1PS.508-.BJ..-.BA0 ANS.-500LN-04 2) 1400 1PS.404-.BJ..-.BA0 1PS.408-.BJ..-.BA0 1) 2) Alternative combination with Option C29 "Rated output of the lower output level". Please inquire regarding higher ambient temperatures and other combinations. Outside the IE code classification according to IEC 60034-30. 9 410 650 870 1030 1) 985 1) 1200 1) 1150 1) 1100 1) 1340 1) 1280 1) 1230 1) 1PS0 and 1PS1 motors Derating tables for increased ambient temperatures and site altitudes Rated output for Rated output for standard version ambient temperature and site altitude +40 °C, 1000 m +45 °C, 1000 m +50 °C, 1000 m +55 °C, 1000 m D11 D12 D13 +40 °C, 1500 m +45 °C, 1500 m +50 °C, 1500 m D06 D11+D06 D12+D06 +40 °C, 2000 m +45 °C, 2000 m D07 D11+D07 Additional identification code -Z with appropriate order codes +40 °C, 2500 m D08 Winding utilization 130°C (B) Type Motor type IE class Prated kW Padm kW Padm kW Padm kW 1PS0 and 1PS1 motors - 6-pole 1PS.095-.BD..-.CA3 ANG.-090LR-06 IE2 0,75 0,75 0,75 0,75 1PS.098-.BD..-.CA3 ANG.-090LS-06 IE2 1,1 1,1 1,1 1,1 1,5 1PS.106-.BD..-.CA3 ANG.-100LS-06 IE2 1,5 1,5 1,5 1PS.113-.BD..-.CA3 ANG.-112MS-06 IE2 2,2 2,2 2,2 2,2 1PS.131-.BD..-.CA3 ANG.-132SR-06 IE2 3 3 3 3 1PS.133-.BD..-.CA3 ANG.-132MR-06 IE2 4 4 4 4 1PS.135-.BD..-.CA3 ANG.-132MS-06 IE2 5,5 5,5 5,5 5 1) 1PS.163-.BD..-.CA3 ANG.-160MR-06 IE2 7,5 7,5 7,5 7,5 1PS.166-.BD..-.CA3 ANG.-160LS-06 IE2 11 11 11 11 1PS.186-.BD..-.CA3 ANG.-180LS-06 IE2 15 15 15 15 1PS.206-.BD..-.CA3 ANG.-200LR-06 IE2 18,5 18,5 18,5 18,5 1PS.208-.BD..-.CA3 ANG.-200LS-06 IE2 22 22 22 22 1PS.223-.BD..-.CA3 ANG.-225MS-06 IE2 30 30 30 30 1PS.253-.BD..-.CA3 ANG.-250MM-06 IE2 37 37 37 37 1PS.280-.BD..-.CA3 ANG.-280SL-06 IE2 45 45 45 45 1PS.283-.BD..-.CA3 ANG.-280MM-06 IE2 55 55 55 55 1PS.311-.BD..-.CA3 ANG.-315SL-06 IE2 75 75 75 75 1PS.313-.BD..-.CA3 ANG.-315ML-06 IE2 90 90 90 90 1PS.314-.BD..-.CA3 ANG.-315MM-06 IE2 110 110 110 110 1PS.315-.BD..-.CA3 ANG.-315MN-06 IE2 132 132 132 120 1) 1) 135 1) 1PS.316-.BD..-.CA3 ANG.-315LL-06 IE2 160 160 145 1PS.317-.BD..-.CA3 ANG.-315LM-06 IE2 200 180 1) 170 1) 160 1) 1PS.317-.BD..-.CB3 ANG.-315LM-063) IE2 200 190 1) 180 1) 170 1) 1) 1) 220 1) 230 1PS.356-.BD..-.CB2 ANG.-355LB-06 IE2 250 240 1PS.357-.BH..-.CA0 ANS.-355LC-06 IE2 280 265 1) 255 1) 245 1) 1PS.358-.BH..-.CA0 ANS.-355LD-06 IE2 315 300 1) 290 1) 275 1) 1) 1) 310 1) 325 1PS.357-.BJ..-.CA0 ANS.-355LN-06 IE2 355 340 1PS.358-.BJ..-.CA0 ANS.-355LN-06 2) 400 380 1) 365 1) 350 1) ANS.-400LL-06 2) 400 380 1) 365 1) 350 1) 1PS.405-.BJ..-.CA0 ANS.-400LN-06 2) 450 430 1) 410 1) 395 1) 1PS.407-.BJ..-.CA0 ANS.-400LN-06 2) 500 480 1) 460 1) 440 1) ANS.-450LL-06 2) 560 535 1) 1) 490 1) 1PS.455-.BJ..-.CA0 ANS.-450LL-06 2) 630 600 1) 580 1) 550 1) 1PS.457-.BJ..-.CA0 ANS.-450LN-06 2) 710 680 1) 650 1) 620 1) 1PS.458-.BJ..-.CA0 ANS.-450LN-06 2) 800 765 1) 1) 700 1) 1PS.505-.BJ..-.CA0 ANS.-500LL-06 2) 900 860 1) 825 1) 790 1) 1PS.507-.BJ..-.CA0 ANS.-500LN-06 2) 1000 960 1) 920 1) 880 1) ANS.-500LN-06 2) 1PS.404-.BJ..-.CA0 1PS.453-.BJ..-.CA0 1PS.508-.BJ..-.CA0 1) 2) 3) 1075 1120 Alternative combination with Option C29 "Rated output of the lower output level". Please inquire regarding higher ambient temperatures and other combinations. Outside the IE code classification according to IEC 60034-30. Special rotors with copper bars. 10 1) 515 735 1030 1) 985 1) 1PS4 and 1PS5 motors - type of protection "Explosion-proof enclosure" Derating tables for increased ambient temperatures and site altitudes Rated output for Rated output for standard version ambient temperature and site altitude +40 °C, 1000 m +45 °C, 1000 m +50 °C, 1000 m +55 °C, 1000 m D11 D12 D13 +40 °C, 1500 m +45 °C, 1500 m +50 °C, 1500 m D06 D11+D06 D12+D06 +40 °C, 2000 m +45 °C, 2000 m D07 D11+D07 Additional identification code -Z with appropriate order codes +40 °C, 2500 m D08 Winding utilization 130°C (B) Type Motor type IE class Prated kW Padm kW Padm kW Padm kW 0,37 1PS4 and 1PS5 motors - 2-pole 1PS5070-.BD..-4AA3 DNGW-071BR-02 1) 0,37 0,37 0,37 1PS5071-.BD..-4AA3 DNGW-071BS-02 1) 0,55 0,55 0,55 0,55 1PS5080-.BD..-4AA3 DNGW-080BR-02 IE2 0,75 0,75 0,75 0,75 1PS5081-.BD..-4AA3 DNGW-080BS-02 IE2 1,1 1,1 1,1 1,1 1PS5095-.BD..-4AA3 DNGW-090LR-02 IE2 1,5 1,5 1,5 1,5 2,2 1PS5098-.BD..-4AA3 DNGW-090LS-02 IE2 2,2 2,2 2,2 1PS5106-.BD..-4AA3 DNGW-100LS-02 IE2 3 3 3 3 1PS5113-.BD..-4AA3 DNGW-112MS-02 IE2 4 4 4 4 1PS5131-.BD..-4AA3 DNGW-132SR-02 IE2 5,5 5,5 5,5 5,5 1PS5132-.BD..-4AA3 DNGW-132SS-02 IE2 7,5 7,5 7,5 7,5 1PS5163-.BD..-4AA3 DNGW-160MR-02 IE2 11 11 11 11 1PS5165-.BD..-4AA3 DNGW-160MS-02 IE2 15 15 15 15 1PS5166-.BD..-4AA3 DNGW-160LS-02 IE2 18,5 18,5 18,5 18,5 1PS5183-.BD..-4AA3 DNGW-180MS-02 IE2 22 22 22 22 1PS5206-.BD..-4AA3 DNGW-200LR-02 IE2 30 30 30 30 1PS5208-.BD..-4AA3 DNGW-200LS-02 IE2 37 37 37 37 1PS5223-.BD..-4AA3 DNGW-225MS-02 IE2 45 45 45 45 1PS5253-.BD..-4AA3 DNGW-250MM-02 IE2 55 55 55 50 1PS5280-.BD..-4AA3 DNGW-280SL-02 IE2 75 75 75 75 1PS5283-.BD..-4AA3 DNGW-280MM-02 IE2 90 90 90 90 1PS5311-.BD..-4AA3 DNGW-315SL-02 IE2 110 110 110 110 1PS5313-.BD..-4AA3 DNGW-315ML-02 IE2 132 132 120 2) 110 2) 1PS5315-.BD..-4AA3 DNGW-315MN-02 IE2 160 160 145 2) 135 2) 2) 170 2) 2) 180 1PS5316-.BD..-4AA3 DNGW-315LL-02 IE2 200 190 1PS5318-.BD..-4AA3 DNGW-315LN-02 IE2 250 240 2) 230 2) 210 2) 1PS5353-.BD..-4AA3 DNGW-355MR-02 IE2 315 300 2) 290 2) 275 2) 2) 2) 315 2) 330 1PS5355-.BD..-4AA3 DNGW-355MS-02 IE2 360 340 1PS5357-.BD..-4AA3 DNGW-355MT-02 1) 460 440 2) 430 2) 405 2) DNS.-355LD-02 1) 400 380 2) 365 2) 350 2) 1PS.358-.BJ..-4AA0 DNS.-355LX-02 1) 450 430 2) 410 2) 395 2) 1PS.404-.BJ..-4AA0 DNS.-400LL-02 1) 450 430 2) 410 2) 395 2) DNS.-400LN-02 1) 500 480 2) 2) 440 2) 1PS.407-.BJ..-4AA0 DNS.-400LN-02 1) 560 535 2) 515 2) 490 2) 1PS.408-.BJ..-4AA0 DNS.-400LX-02 1) 630 605 2) 580 2) 550 2) 1PS.453-.BJ..-4AA0 DNS.-450LL-02 1) 630 605 2) 2) 550 2) 1PS.455-.BJ..-4AA0 DNS.-450LL-02 1) 710 680 2) 650 2) 625 2) 1PS.457-.BJ..-4AA0 DNS.-450LN-02 1) 800 765 2) 735 2) 700 2) 1PS.458-.BJ..-4AA0 DNS.-450LN-02 1) 900 860 2) 2) 790 2) 1PS.505-.BJ..-4AA0 DNS.-500LL-02 1) 1000 960 2) 920 2) 880 2) DNS.-500LN-02 1) 1PS.358-.BH..-4AA0 1PS.405-.BJ..-4AA0 1PS.508-.BJ..-4AA0 1150 1200 1) Outside the IE code classification according to IEC 60034-30. 2) Alternative combination with Option C29 "Rated output of the lower output level". Please inquire regarding higher ambient temperatures and other combinations. 11 2) 460 580 825 1100 2) 1055 2) 1PS4 and 1PS5 motors - type of protection "Explosion-proof enclosure" Derating tables for increased ambient temperatures and site altitudes Rated output for Rated output for standard version ambient temperature and site altitude +40 °C, 1000 m +45 °C, 1000 m +50 °C, 1000 m +55 °C, 1000 m D11 D12 D13 +40 °C, 1500 m +45 °C, 1500 m +50 °C, 1500 m D06 D11+D06 D12+D06 +40 °C, 2000 m +45 °C, 2000 m D07 D11+D07 Additional identification code -Z with appropriate order codes +40 °C, 2500 m D08 Winding utilization 130°C (B) Type Motor type IE class Prated kW Padm kW Padm kW Padm kW 1PS4 and 1PS5 motors - 4-pole 1PS5070-.BD..-4BA3 DNGW-071BR-04 1) 0,25 0,25 0,25 0,25 1PS5071-.BD..-4BA3 DNGW-071BS-04 1) 0,37 0,37 0,37 0,37 1PS5080-.BD..-4BA3 DNGW-080BR-04 1) 0,55 0,55 0,55 0,55 1PS5081-.BD..-4BA3 DNGW-080BS-04 IE2 0,75 0,75 0,75 0,75 1PS5095-.BD..-4BA3 DNGW-090LR-04 IE2 1,1 1,1 1,1 1,1 1PS5098-.BD..-4BA3 DNGW-090LS-04 IE2 1,5 1,5 1,5 1,5 2,2 1PS5106-.BD..-4BA3 DNGW-100LR-04 IE2 2,2 2,2 2,2 1PS5108-.BD..-4BA3 DNGW-100LS-04 IE2 3 3 3 3 1PS5113-.BD..-4BA3 DNGW-112MS-04 IE2 4 4 4 4 1PS5131-.BD..-4BA3 DNGW-132SR-04 IE2 5,5 5,5 5,5 5,5 1PS5133-.BD..-4BA3 DNGW-132MS-04 IE2 7,5 7,5 7,5 7,5 1PS5163-.BD..-4BA3 DNGW-160MR-04 IE2 11 11 11 11 1PS5166-.BD..-4BA3 DNGW-160LS-04 IE2 15 15 15 15 1PS5183-.BD..-4BA3 DNGW-180MR-04 IE2 18,5 18,5 18,5 18,5 1PS5186-.BD..-4BA3 DNGW-180LS-04 IE2 22 22 22 22 1PS5206-.BD..-4BA3 DNGW-200LS-04 IE2 30 30 30 30 1PS5220-.BD..-4BA3 DNGW-225SR-04 IE2 37 37 37 37 1PS5223-.BD..-4BA3 DNGW-225MS-04 IE2 45 45 45 45 1PS5253-.BD..-4BA3 DNGW-250MM-04 IE2 55 55 55 50 1PS5280-.BD..-4BA3 DNGW-280SL-04 IE2 75 75 75 75 1PS5283-.BD..-4BA3 DNGW-280MM-04 IE2 90 90 90 90 1PS5311-.BD..-4BA3 DNGW-315SL-04 IE2 110 110 110 100 1PS5313-.BD..-4BA3 DNGW-315ML-04 IE2 132 132 132 120 2) 1PS5315-.BD..-4BA3 DNGW-315MN-04 IE2 160 160 145 2) 135 2) 1PS5316-.BD..-4BA3 DNGW-315LL-04 IE2 200 190 2) 180 2) 170 2) 1PS5317-.BD..-4BA3 DNGW-315LM-04 IE2 250 240 2) 230 2) 210 2) 2) 2) 275 2) 290 2) 1PS5353-.BD..-4BA3 DNGW-355MR-04 IE2 315 300 1PS5355-.BD..-4BA3 DNGW-355MS-04 IE2 360 340 2) 330 2) 315 2) DNGW-355MT-04 1) 450 440 2) 430 2) 405 2) 1PS.350-.BH..-4BA0 DNS.-355LD-04 1) 400 380 2) 365 2) 350 2) 1PS.357-.BJ..-4BA0 DNS.-355LN-04 1) 450 430 2) 410 2) 395 2) DNS.-355LX-04 1) 500 480 2) 2) 440 2) 1PS.404-.BJ..-4BA0 DNS.-400LL-04 1) 500 480 2) 460 2) 440 2) 1PS.405-.BJ..-4BA0 DNS.-400LN-04 1) 560 535 2) 515 2) 490 2) 1PS.407-.BJ..-4BA0 DNS.-400LN-04 1) 630 600 2) 2) 550 2) 1PS.408-.BJ..-4BA0 DNS.-400LX-04 1) 710 680 2) 650 2) 620 2) 1PS.455-.BJ..-4BA0 DNS.-450LL-04 1) 800 765 2) 735 2) 700 2) 1PS.457-.BJ..-4BA0 DNS.-450LN-04 1) 900 860 2) 2) 790 2) 1PS.458-.BJ..-4BA0 DNS.-450LN-04 1) 950 910 2) 870 2) 835 2) DNS.-500LL-04 1) 2) 2) 880 2) 1PS.505-.BJ..-4BA0 DNS.-500LL-04 1) 1120 1PS.507-.BJ..-4BA0 1PS.508-.BJ..-4BA0 DNS.-500LN-04 DNS.-500LN-04 1) 1250 1400 1PS5357-.BD..-4BA3 1PS.358-.BJ..-4BA0 1PS.504-.BJ..-4BA0 1) 960 1000 1) Outside the IE code classification according to IEC 60034-30. 2) Alternative combination with Option C29 "Rated output of the lower output level". Please inquire regarding higher ambient temperatures and other combinations. 12 1075 2) 1200 1340 2) 2) 460 580 825 920 1030 2) 985 2) 1150 1280 2) 1100 1230 2) 2) 2) 1PS4 and 1PS5 motors - type of protection "Explosion-proof enclosure" Derating tables for increased ambient temperatures and site altitudes Rated output for Rated output for standard version ambient temperature and site altitude +40 °C, 1000 m +45 °C, 1000 m +50 °C, 1000 m +55 °C, 1000 m D11 D12 D13 +40 °C, 1500 m +45 °C, 1500 m +50 °C, 1500 m D06 D11+D06 D12+D06 +40 °C, 2000 m +45 °C, 2000 m D07 D11+D07 Additional identification code -Z with appropriate order codes +40 °C, 2500 m D08 Winding utilization 130°C (B) Type Motor type IE class Prated kW Padm kW Padm kW Padm kW 1PS4 and 1PS5 motors - 6-pole 1PS5071-.BD..-4CA3 DNGW-071BS-06 1) 0,25 0,25 0,25 0,25 1PS5080-.BD..-4CA3 DNGW-080BR-06 1) 0,37 0,37 0,37 0,37 1PS5081-.BD..-4CA3 DNGW-080BS-06 1) 0,55 0,55 0,55 0,55 1PS5095-.BD..-4CA3 DNGW-090LR-06 IE2 0,75 0,75 0,75 0,75 1PS5098-.BD..-4CA3 DNGW-090LS-06 IE2 1,1 1,1 1,1 1,1 1PS5106-.BD..-4CA3 DNGW-100LS-06 IE2 1,5 1,5 1,5 1,5 1PS5113-.BD..-4CA3 DNGW-112MS-06 IE2 2,2 2,2 2,2 2,2 1PS5131-.BD..-4CA3 DNGW-132SR-06 IE2 3 3 3 3 1PS5133-.BD..-4CA3 DNGW-132MR-06 IE2 4 4 4 4 1PS5135-.BD..-4CA3 DNGW-132MS-06 IE2 5,5 5,5 5,5 5 2) 1PS5163-.BD..-4CA3 DNGW-160MR-06 IE2 7,5 7,5 7,5 7,5 1PS5166-.BD..-4CA3 DNGW-160LS-06 IE2 11 11 11 11 1PS5186-.BD..-4CA3 DNGW-180LS-06 IE2 15 15 15 15 1PS5206-.BD..-4CA3 DNGW-200LR-06 IE2 18,5 18,5 18,5 18,5 1PS5208-.BD..-4CA3 DNGW-200LS-06 IE2 22 22 22 22 1PS5223-.BD..-4CA3 DNGW-225MS-06 IE2 30 30 30 30 1PS5253-.BD..-4CA3 DNGW-250MM-06 IE2 37 37 37 37 1PS5280-.BD..-4CA3 DNGW-280SL-06 IE2 45 45 45 45 1PS5283-.BD..-4CA3 DNGW-280MM-06 IE2 55 55 55 55 1PS5311-.BD..-4CA3 DNGW-315SL-06 IE2 75 75 75 75 1PS5313-.BD..-4CA3 DNGW-315ML-06 IE2 90 90 90 90 1PS5314-.BD..-4CA3 DNGW-315MM-06 IE2 110 110 110 110 1PS5315-.BD..-4CA3 DNGW-315MN-06 IE2 132 132 132 1PS5316-.BD..-4CA3 DNGW-315LL-06 1PS5317-.BD..-4CA3 DNGW-315LM-06 1PS5353-.BD..-4CA3 DNGW-355MR-06 3) 120 2) 2) 135 2) IE2 160 160 145 IE2 200 180 2) 170 2) 160 2) IE2 280 260 2) 250 2) 240 2) 2) 2) 270 2) 280 1PS5355-.BD..-4CA3 DNGW-355MS-06 IE2 315 300 1PS5357-.BD..-4CA3 DNGW-355MT-06 IE2 360 340 2) 330 2) 305 2) 355 340 2) 325 2) 310 2) 2) 365 2) 350 2) 1PS.357-.BJ..-4CA0 DNS.-355LN-06 IE2 1PS.358-.BJ..-4CA0 DNS.-355LN-06 1) 400 380 1PS.404-.BJ..-4CA0 DNS.-400LL-06 1) 400 380 2) 365 2) 350 2) DNS.-400LN-06 1) 450 430 2) 2) 395 2) 1PS.407-.BJ..-4CA0 DNS.-400LN-06 1) 500 480 2) 460 2) 440 2) 1PS.453-.BJ..-4CA0 DNS.-450LL-06 1) 560 535 2) 515 2) 490 2) 1PS.455-.BJ..-4CA0 DNS.-450LL-06 1) 630 600 2) 2) 550 2) 1PS.457-.BJ..-4CA0 DNS.-450LN-06 1) 710 680 2) 650 2) 620 2) 1PS.458-.BJ..-4CA0 DNS.-450LN-06 1) 800 765 2) 735 2) 700 2) 1PS.505-.BJ..-4CA0 DNS.-500LL-06 1) 900 860 2) 2) 790 2) 1PS.507-.BJ..-4CA0 DNS.-500LN-06 1) 1000 960 2) 920 2) 880 2) DNS.-500LN-06 1) 1PS.405-.BJ..-4CA0 1PS.508-.BJ..-4CA0 1) Outside the IE code classification according to IEC 60034-30. 2) Alternative combination with Option C29 "Rated output of the lower output level". 3) 1075 1120 Please inquire regarding higher ambient temperatures and other combinations. For +40 °C/+1000 m utilization F. 13 2) 410 580 825 1030 2) 985 2) SIMOTICS XP 1MD5 motor series Motors in cast-iron version · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE2 in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated Frame Prated 50Hz size 60Hz Article No. DNGW-071BR-02 DNGW-071BS-02 DNGW-080BR-02 DNGW-080BS-02 DNGW-090LR-02 DNGW-090LS-02 DNGW-100LS-02 DNGW-112MS-02 DNGW-132SR-02 DNGW-132SS-02 DNGW-160MR-02 DNGW-160MS-02 DNGW-160LS-02 DNGW-180MS-02 DNGW-200LR-02 DNGW-200LS-02 DNGW-225MS-02 DNGW-250MM-02 DNGW-280SL-02 DNGW-280MM-02 DNGW-315SL-02 DNGW-315ML-02 DNGW-315MN-02 DNGW-315LL-02 DNGW-315LN-02 1) DNGW-355MR-02 1) DNGW-355MS-02 1) DNGW-355MT-02 1MD50701MD50711MD50801MD50811MD50951MD50981MD51061MD51131MD51311MD51321MD51631MD51651MD51661MD51831MD52061MD52081MD52231MD52531MD52801MD52831MD53111MD53131MD53151MD53161MD53181MD53531MD53551MD5357- Price for 1 unit for IM B3 kW 2-pole: 3000 rpm at 50Hz 0,37 71 B 0,43 IE2 0,55 71 B 0,63 IE2 0,75 80 B 0,86 IE2 1,1 80 B 1,27 IE2 1,5 90 L 1,75 IE2 2,2 90 L 2,55 IE2 3 100 L 3,45 IE2 4 112 M 4,55 IE2 5,5 132 S 6,3 IE2 7,5 132 S 8,6 IE2 11 160 M 12,6 IE2 15 160 M 17,3 IE2 18,5 160 L 21,3 IE2 22 180 M 24,5 IE2 30 200 L 33,5 IE2 37 200 L 41,5 IE2 45 225 M 51 IE2 55 250 M 62 IE2 75 280 S 84 IE2 90 280 M 101 IE2 110 315 S 123 IE2 132 315 M 148 IE2 160 315 M 180 IE2 200 315 L 224 IE2 250 315 L 270 IE2 315 355 M 340 IE2 360 355 M 385 IE2 460 355 M 500 IE2 Operating modes Frame size Mains-fed operation 71 ... 355 Converter-fed operation, standard insulation 71 ... 355 Voltages 355 690 V D, 50Hz 230 V D / 400 V S, 50Hz 71 ... 100 500 V S, 50Hz 71 ... 315 500 V D, 50Hz 71 ... 355 400 V D / 690 V S, 50Hz 71 ... 355 460 V D, 60Hz (60Hz-output) 71 ... 355 400/690 V D/S, 50Hz and 71 ... 355 460 V D, 60Hz (60Hz-output) For other voltages see options list 71 ... 315 Types of construction IM B3 71 ... 355 IM B5 71 ... 315 IM B34 71 ... 112 IM B14 71 ... 112 IM V1/canopy 71 ... 355 71 ... 355 IM B35 For other types of construction see options list 71 ... 355 1) Direction of rotation must be specified (order code K97 or K98). BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD 0 1 3 5 6 9 9 L2F L1N 9 … 0 1 2 3 4 6 9 14 1.540,– 1.600,– 1.650,– 1.800,– 1.960,– 2.300,– 2.600,– 3.060,– 3.720,– 4.580,– 5.840,– 7.170,– 8.050,– 8.980,– 11.300,– 13.400,– 15.300,– 18.000,– 23.400,– 26.900,– 32.300,– 37.000,– 44.300,– 53.500,– 66.000,– 83.500,– 95.500,– 120.000,– Order code - 0 1 Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version b. -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 -4AA1 … Discount level B FS Motor type Options acc. surcharge price list 1MD5… kW IE class SIMOTICS XP 1MD5 motor series Motors in cast-iron version · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE2 in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated Frame Prated 50Hz size 60Hz Article No. DNGW-071BR-04 DNGW-071BS-04 DNGW-080BR-04 DNGW-080BS-04 DNGW-090LR-04 DNGW-090LS-04 DNGW-100LR-04 DNGW-100LS-04 DNGW-112MS-04 DNGW-132SR-04 DNGW-132MS-04 DNGW-160MR-04 DNGW-160LS-04 DNGW-180MR-04 DNGW-180LS-04 DNGW-200LS-04 DNGW-225SR-04 DNGW-225MS-04 DNGW-250MM-04 DNGW-280SL-04 DNGW-280MM-04 DNGW-315SL-04 DNGW-315ML-04 DNGW-315MN-04 DNGW-315LL-04 DNGW-315LM-04 1) DNGW-355MR-04 1) DNGW-355MS-04 1) DNGW-355MT-04 1MD50701MD50711MD50801MD50811MD50951MD50981MD51061MD51081MD51131MD51311MD51331MD51631MD51661MD51831MD51861MD52061MD52201MD52231MD52531MD52801MD52831MD53111MD53131MD53151MD53161MD53171MD53531MD53551MD5357- Price for 1 unit for IM B3 kW 4-pole: 1500 rpm at 50Hz 0,25 71 B 0,29 IE2 0,37 71 B 0,43 IE2 0,55 80 B 0,63 IE2 0,75 80 B 0,86 IE2 1,1 90 L 1,27 IE2 1,5 90 L 1,75 IE2 2,2 100 L 2,55 IE2 3 100 L 3,45 IE2 4 112 M 4,55 IE2 5,5 132 S 6,3 IE2 7,5 132 M 8,6 IE2 11 160 M 12,6 IE2 15 160 L 17,3 IE2 18,5 180 M 21,3 IE2 22 180 L 25,3 IE2 30 200 L 34,5 IE2 37 225 S 40 IE2 45 225 M 49,5 IE2 55 250 M 63 IE2 75 280 S 86 IE2 90 280 M 104 IE2 110 315 S 127 IE2 132 315 M 152 IE2 160 315 M 184 IE2 200 315 L 230 IE2 250 315 L 280 IE2 315 355 M 350 IE2 360 355 M 390 IE2 460 355 M 490 IE2 Operating modes Frame size Mains-fed operation 71 ... 355 Converter-fed operation, standard insulation 71 ... 355 Voltages 355 690 V D, 50Hz 230 V D / 400 V S, 50Hz 71 ... 100 500 V S, 50Hz 71 ... 315 500 V D, 50Hz 71 ... 355 400 V D / 690 V S, 50Hz 71 ... 355 460 V D, 60Hz (60Hz-output) 71 ... 355 400/690 V D/S, 50Hz and 71 ... 355 460 V D, 60Hz (60Hz-output) For other voltages see options list 71 ... 315 Types of construction IM B3 71 ... 355 IM B5 71 ... 315 IM B34 71 ... 112 IM B14 71 ... 112 IM V1/canopy 71 ... 355 71 ... 355 IM B35 For other types of construction see options list 71 ... 355 1) Direction of rotation must be specified (order code K97 or K98). BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD 0 1 3 5 6 9 9 L2F L1N 9 … 0 1 2 3 4 6 9 15 1.440,– 1.490,– 1.550,– 1.600,– 1.750,– 1.900,– 2.230,– 2.520,– 2.970,– 3.610,– 4.440,– 5.660,– 6.950,– 7.800,– 8.700,– 10.900,– 13.000,– 14.800,– 17.400,– 22.600,– 25.900,– 31.100,– 35.500,– 42.400,– 51.100,– 62.800,– 79.000,– 90.000,– 112.000,– Order code - 0 1 Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version b. -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 -4BA1 … Options acc. surcharge price list 1MD5… FS Motor type Discount level B kW IE class SIMOTICS XP 1MD5 motor series Motors in cast-iron version · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE2 in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated Frame Prated 50Hz size 60Hz Article No. DNGW-071BS-06 DNGW-080BR-06 DNGW-080BS-06 DNGW-090LR-06 DNGW-090LS-06 DNGW-100LR-06 DNGW-100LS-06 DNGW-112MS-06 DNGW-132SR-06 DNGW-132MR-06 DNGW-132MS-06 DNGW-160MR-06 DNGW-160LS-06 DNGW-180LS-06 DNGW-200LR-06 DNGW-200LS-06 DNGW-225MS-06 DNGW-250MM-06 DNGW-280SL-06 DNGW-280MM-06 DNGW-315SL-06 DNGW-315ML-06 DNGW-315MM-06 DNGW-315MN-06 DNGW-315LL-06 DNGW-315LM-06 DNGW-355MR-06 DNGW-355MS-06 DNGW-355MT-06 1MD50701MD50801MD50811MD50951MD50981MD51051MD51061MD51131MD51311MD51331MD51351MD51631MD51661MD51861MD52061MD52081MD52231MD52531MD52801MD52831MD53111MD53131MD53141MD53151MD53161MD53171MD53531MD53551MD5357- Price for 1 unit for IM B3 kW 6-pole: 1000 rpm at 50Hz 0,25 71 B 0,25 IE2 0,37 80 B 0,37 IE2 0,55 80 B 0,55 IE2 0,75 90 L 0,75 IE2 1,1 90 L --IE2 --100 L 1,1 IE2 1,5 100 L 1,5 IE2 2,2 112 M 2,2 IE2 3 132 S 3 IE2 4 132 M 3,7 IE2 5,5 132 M 5,5 IE2 7,5 160 M 7,5 IE2 11 160 L 11 IE2 15 180 L 15 IE2 18,5 200 L 18,5 IE2 22 200 L 22 IE2 30 225 M 30 IE2 37 250 M 37 IE2 45 280 S 45 IE2 55 280 M 55 IE2 75 315 S 75 IE2 90 315 M 90 IE2 110 315 M 110 IE2 132 315 M 132 IE2 160 315 L 150 IE2 200 315 L 200 IE2 280 355 M 290 IE2 315 355 M 330 IE2 360 355 M 380 IE2 Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 690 V D, 50Hz 230 V D / 400 V S, 50Hz 500 V S, 50Hz 500 V D, 50Hz 400 V D / 690 V S, 50Hz 460 V D, 60Hz (60Hz-output) 400/690 V D/S, 50Hz and 460 V D, 60Hz (60Hz-output) For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 For other types of construction see options list Frame size 71 ... 355 71 ... 355 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 -4CA1 1.580,– 1.640,– 1.690,– 1.850,– 2.000,– 2.180,– 2.350,– 3.120,– 3.790,– 4.650,– 5.280,– 5.910,– 7.250,– 9.060,– 10.200,– 11.300,– 15.300,– 18.000,– 23.300,– 26.700,– 32.000,– 36.600,– 40.100,– 43.700,– 52.600,– 64.700,– 81.400,– 92.700,– 115.000,– Order code - 0 1 355 71 ... 100 71 ... 315 71 ... 355 71 ... 355 71 ... 355 71 ... 355 0 1 3 5 6 9 9 L2F L1N 71 ... 315 9 … 71 ... 355 71 ... 315 71 ... 112 71 ... 112 71 ... 355 71 ... 355 71 ... 355 0 1 2 3 4 6 9 Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version b. 16 … Options acc. surcharge price list 1MD5… FS Motor type Discount level B kW IE class SIMOTICS XP 1MD5 motor series Article No. supplements Selection and ordering data Voltages 1MD5. . . - . . . Voltage Additional Motor series code identification SIMOTICS XP 11th position code with Surcharge / List price EURO of the order code Article No. and plain text .-.... if required Discount level B Frame size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 Optional voltages 690 V D, 50Hz 0 N N N N N N N N N N N N N o.MP. 230 V D / 400 V S, 50Hz 1 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N N 500 V S, 50Hz 3 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N 500 V D, 50Hz 5 65,– 74,– 87,– 107,– 130,– o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 400 V D / 690 V S, 50Hz 6 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 415 V S, 50Hz 9 L1C 31,– 35,– 41,– 51,– 62,– 80,– 98,– 127,– 146,– 205,– 234,– 302,– 392,– N 415 V D, 50Hz 9 L1D 31,– 35,– 41,– 51,– 62,– 80,– 98,– 127,– 146,– 205,– 234,– 302,– 392,– N 380 V D / 660 V S, 50Hz 9 L1L 31,– 35,– 41,– 51,– 62,– 80,– 98,– 127,– 146,– 205,– 234,– 302,– 392,– N 460 V S, 60Hz (60Hz-output) 9 L2E 31,– 35,– 41,– 51,– 62,– 80,– 98,– 127,– 146,– N N N N N 460 V D, 60Hz (60Hz-output) 9 L2F 31,– 35,– 41,– 51,– 62,– 80,– 98,– 127,– 146,– 205,– 234,– 302,– 392,– 512,– 575 V S, 60Hz (60Hz-output) 9 L2L 31,– 35,– 41,– 51,– 62,– 80,– 98,– 127,– 146,– 205,– 234,– 302,– 392,– 512,– 575 V D, 60Hz (60Hz-output) 9 L2M 31,– 35,– 41,– 51,– 62,– 80,– 98,– 127,– 146,– 205,– 234,– 302,– 392,– 512,– 440 V D, 60Hz (60Hz-output) 230/400 V D/S, 50Hz and 460 V S, 60Hz (60Hz-output) 9 L2X 31,– 35,– 41,– 51,– 62,– 80,– 98,– 127,– 146,– 205,– 234,– 302,– 392,– N 9 L1M 31,– 35,– 41,– 51,– 62,– 80,– 98,– 127,– 146,– N N N N N 400/690 V D/S, 50Hz and 460 V D, 60Hz (60Hz-output) 9 L1N 31,– 35,– 41,– 51,– 62,– 80,– 98,– 127,– 146,– 205,– 234,– 302,– 392,– 512,– Types of construction Mounting Additional Motor series type code identification SIMOTICS XP 12th position code with Surcharge / List price EURO of the order code Article No. and plain text 1MD5. . . - . . . . -.... if required Discount level B Frame size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 Optional types of construction IM B3 0 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. IM B5 1 73,– 82,– 95,– 117,– 146,– 199,– 266,– 431,– 508,– 637,– 809,– 1.010,– 1.330,– N IM B34 2 91,– 95,– 118,– 146,– 189,– N N N N N N N N N IM B14 3 73,– 82,– 95,– 117,– 146,– N N N N N N N N N IM V1, with canopy 4 127,– 150,– 168,– 199,– 243,– 321,– 433,– 699,– 856,– 1.070,– 1.340,– 1.650,– 2.190,– 3.160,– 809,– 1.090,– 1.410,– 1.860,– 2.980,– o.MP. o.MP. IM B35 6 91,– 95,– 118,– 146,– 189,– 305,– 467,– 546,– 637,– IM V6 9 M1E o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. IM V5, with canopy 9 M1F 55,– 66,– 77,– 81,– 98,– 126,– 164,– 264,– 348,– IM V3 9 M1G 73,– 82,– 94,– 117,– 146,– 199,– 266,– 431,– 508,– IM V15, with canopy 9 M2K 145,– 163,– 191,– 228,– 286,– 427,– 634,– 814,– 985,– IM V18, with canopy 9 M2M 127,– 150,– 168,– 199,– 243,– N N N N N □ = Standard version o.MP. = Without surcharge a.A. = On request N = Not available For dual voltages 230 V/400 V, 220 V/380 V, 400 V/690 V or 380 V/660 V: - For motors for converter-fed operation, the converter rating plate is stamped with 380 V or 400 V. Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version b. 17 o.MP. 437,– o.MP. N 546,– 657,– 874,– N 637,– 809,– 1.010,– 1.330,– N 1.240,– 1.620,– 2.050,– 2.720,– N N N N N SIMOTICS XP 1MD5 motor series Selection and ordering data Special versions Additional Motor series identification SIMOTICS XP code -Z with Surcharge / List price EURO Discount level B order code and plain text 1MD5. . . - . . . . . - . . . . -Z if required Frame size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 Special electrical designs / winding protection Motor protection with 3 PTC thermistors for switching-off - without lightning arresters, sole protection not included Motor protection with 2 x 3 PTC thermistors for prewarning / switching-off - without lightning arresters, A11 A12 249,– 249,– 249,– 249,– 249,– 249,– 249,– 349,– 349,– 349,– 349,– 349,– 349,– N N N N N N N N N N N N N N 571,– A15 A16 A42 449,– 449,– 449,– 449,– 449,– 449,– 449,– 593,– 593,– 593,– 727,– 727,– 727,– N N N N N N N N N N N N N N 1.060,– N N N N N N N N N N N N N 3.000,– sole protection not included Motor protection with 3 PTC thermistors for switching-off as sole protection with inverter (TMS) Motor protection with 2 x 3 PTC thermistors for prewarning/switching-off as sole protection with inverter (TMS) 2 double resistance thermometers PT100 for 4-wire connection from terminal box, rolling-contact bearing 1 x DE and 1 x NDE 6 PT100 resistance thermometers in stator winding, 3-wire circuit from terminals of the auxiliary terminal box Ambient temperature +45°C; Insulation class F utilized B; reduction of rating 4% Ambient temperature +50°C; Insulation class F utilized B; reduction of rating 8% A64 C22 C23 N N N N N N N N N N N N N 2.690,– 43,– 43,– 43,– 50,– 50,– 66,– 66,– 84,– 84,– 96,– 96,– 112,– 112,– 230,– 43,– 43,– 43,– 50,– 50,– 66,– 66,– 84,– 84,– 96,– 96,– 112,– 112,– 230,– Colors and paint finish V09 V10 □ □ □ □ □ 276,– 315,– 358,– 406,– 460,– 523,– 600,– 686,– 782,– W14 108,– 127,– 148,– 172,– 199,– 231,– 269,– 313,– 361,– V11 553,– 629,– 716,– 812,– 919,– 1.050,– 1.200,– 1.370,– K24 K23 Y54 ● and special coating RAL… Y51 ● and special coating RAL… 22,– o.MP. 63,– 22,– o.MP. 63,– 29,– o.MP. 63,– 29,– o.MP. 106,– 29,– o.MP. 106,– 46,– o.MP. 139,– 46,– o.MP. 139,– 95,– 95,– 95,– 159,– 159,– 209,– Design in gas group IIC, but stamped in IIB Design in double protection additionally for dust Zone 22 at mains operation; no hybrid certification non conductive dust Design additionally for dust Zone 21 at mains operation; no hybrid certification; IP65 design and certification for conductive dust (incl. non conductive dust) M99 W20 o.MP. 73,– o.MP. 87,– o.MP. 91,– o.MP. 109,– o.MP. 122,– W21 196,– 202,– 224,– 240,– Design in double protection additionally for dust Zone 22 at inverter operation; no hybrid certification non conductive dust; options for inverter operation choose separately Design additionally for dust Zone 21 at inverter operation; no hybrid certification; IP65 design and certification for conductive dust (incl. non conductive dust); options for inverter operation choose separately W22 135,– 135,– 135,– 148,– W23 376,– 376,– 376,– D34 D35 D38 D37 o.MP. o.MP. 163,– 163,– Coating system N08 - 110µm (C3-medium) - Corrosion category acc. to EN/ISO 12944-5 = C3 Coating system N14/J08 - 170µm (Chemical industry + On Shore, C5 - Industrial climate) Corrosion category acc. to EN/ISO 12944-5 = C5 (5-15 years) for industrial climate Coating system N14A (Chemical + On Shore, C5 - Industry) Corrosion category acc. to EN/ISO 12944-5 = C5 (5-15 years) for industrial climate Coating system Z21/J08 - 210µm (Off Shore, C5M-M) Corrosion category acc. to EN/ISO 12944-5 = C5 (5-15 years) - sea-climate Without coating, but primed Without coating Special coating in RAL1004,1018,2000,2004,5009,5010,5012,5015,6003,6011,7000,7011,7031,7038,9002 specify special coating system in addition, e.g. V10, V11, W14, etc. RAL colours different to above indicated □ □ □ □ □ □ □ □ □ 890,– 1.010,– 1.150,– 1.300,– 1.470,– 415,– 475,– 542,– 617,– 703,– 1.570,– 1.780,– 2.120,– 2.630,– 3.240,– 3.810,– 86,– o.MP. 194,– 86,– o.MP. 243,– 86,– o.MP. 243,– 86,– o.MP. 243,– 86,– o.MP. 243,– 86,– o.MP. 243,– 98,– o.MP. 243,– 209,– 291,– 365,– 365,– 365,– 365,– 365,– 365,– o.MP. 176,– o.MP. 238,– o.MP. 429,– o.MP. 618,– o.MP. 738,– o.MP. 769,– o.MP. 820,– o.MP. 949,– o.MP. 1.200,– 269,– 344,– 411,– 487,– 800,– 1.440,– 1.510,– 1.630,– 1.900,– 2.400,– 168,– 185,– 388,– 388,– 435,– 452,– 469,– 488,– 507,– 527,– 421,– 441,– 458,– 661,– 747,– 793,– 810,– 828,– 845,– 864,– 882,– o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 163,– 219,– 219,– 219,– 230,– 230,– 335,– 348,– 461,– 675,– 803,– Design for Zones according to ATEX Individual certifications China Energy Efficiency Label Certificate EAC for Eurasien Customs Union Ex-Certification for India (PESO – CCOE) IEC Ex Certificate Special mechanical designs Terminal box on right hand side ( view onto DE ) Terminal box on left hand side ( view onto DE ) Terminal box on top 1 x cable gland standard for not armoured cable - for main terminal box One cable gland standard thread size for auxiliary connection 1 pc. (not armoured cable) Cable gland standard in Ex d (not armoured cable) 1 pc. - only in combination with K53, exact cable data needed Main terminal box flameproof Ex d II C Additional terminal box Ex d II C made of grey cast iron - with standard threats according catalogue; if thread differ please select (W30), due reducer for cable glands limited if Ex d. Additional terminal box Ex e - design / grey cast iron - not in combination with K53 (Ex d-terminal box) Separate auxiliary box terminal for space heater Cable entry side DE Cable entry side NDE Turn of the terminal box about 180° Vibration severity grade A - IEC 60034-14 Vibration severity grade B - IEC 60034-14 - if inverter duty for smallest and highest speed of speed range only Bearing for increased lateral forces (roller bearing DE) including regreasing device - including K40 Metal external fan Regreasing device DE/NDE Bearing insulation NDE for antifriction bearing - binding for frame size 315 - 355 at inverter operation Fixed bearing DE VIK design - incl. W14, W69 Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version b. K09 K10 K11 K54 W33 W91 803,– 163,– 163,– 163,– 219,– 219,– 219,– 230,– 230,– 335,– 348,– 461,– 675,– 803,– 803,– o.Mp. o.Mp. o.Mp. o.Mp. o.Mp. o.Mp. o.Mp. o.Mp. o.Mp. o.Mp. o.Mp. o.Mp. o.Mp. o.Mp. 793,– 793,– 1.100,– 1.100,– 1.390,– 1.390,– □ □ N N □ N N □ N N □ N N N N □ □ 247,– 247,– □ 260,– 260,– □ 380,– 380,– □ 409,– 409,– □ 482,– 482,– □ □ N N □ 55,– 55,– 71,– 55,– 55,– 71,– 55,– 55,– 71,– 78,– 55,– 110,– 78,– 55,– 110,– 78,– 55,– 110,– 112,– 55,– 149,– 112,– 55,– 149,– 212,– 55,– 350,– 212,– 55,– 350,– 249,– 55,– 665,– 249,– 55,– 665,– 249,– 55,– 665,– 249,– 55,– 665,– K53 V43 928,– N 928,– N 928,– N 928,– N 928,– N 1.210,– N 1.210,– N 1.790,– N 1.790,– N 1.790,– N 2.060,– N 2.060,– N 3.320,– N 3.320,– 2.320,– W72 M52 K83 K84 K85 K01 K02 K20 K35 K40 L27 K94 K30 N N o.MP. o.MP. o.MP. N N o.MP. o.MP. o.MP. N N o.MP. o.MP. o.MP. N N o.MP. o.MP. o.MP. N N o.MP. o.MP. o.MP. 220,– N o.MP. o.MP. o.MP. 220,– N o.MP. o.MP. o.MP. 220,– N o.MP. o.MP. o.MP. 678,– N o.MP. o.MP. o.MP. 678,– N o.MP. o.MP. o.MP. 678,– N o.MP. o.MP. o.MP. 698,– N o.MP. o.MP. o.MP. 698,– N o.MP. o.MP. o.MP. 698,– 698,– o.MP. o.MP. o.MP. □ □ □ □ □ □ □ □ □ 418,– N 89,– 456,– N 89,– 516,– N 109,– 569,– N 169,– 576,– N 198,– 620,– N 233,– 620,– 519,– 260,– 629,– 572,– 373,– 673,– 632,– 518,– 798,– 691,– 667,– 980,– 714,– 707,– 1.150,– 738,– 802,– 1.470,– 369,– o.MP. 2.580,– 461,– o.MP. N N N N N N N N N N N N 419,– N 472,– N 532,– N 591,– 2.100,– 614,– 2.230,– 638,– 2.340,– □ □ 2.430,– 2.550,– □ □ □ □ □ □ □ □ □ □ 212,– 260,– 310,– 363,– 419,– 18 □ □ 479,– □ 546,– □ □ 618,– □ □ 695,– □ 778,– □ 867,– 963,– 1.070,– N SIMOTICS XP 1MD5 motor series Selection and ordering data Special versions Additional Motor series identification SIMOTICS XP code -Z with Surcharge / List price EURO Discount level B order code and plain text 1MD5. . . - . . . . . - . . . . -Z if required Special mechanical designs Second rating plate separately Second rating plate installed in terminal box Additional plate with data at inverter duty - data for quadratic torque speed range 1:10 and constant torque in speed range 1:3 and 1:10 Additional plate for customer data (each plate) - data / text have to be give with order Additional data on motor rating plate and on packing sticker - max. 20 digits Space heater 210 - 250 V (min. 200 V, max. 264 V) Enclosure IP56 Enclosure IP65 Operation for both rotations - from 355 in 2-/4-pole increased noise level and reduced power Clockwise rotation viewed to DE - direction of rotation is mandatory for motors frame size 355 in 2-/4-pole design Anti-clockwise rotation viewed to DE - direction of rotation is mandatory for motors frame size 355 in 2-/4-pole design Noise reduction: silencer for air inlet (GG3) - only in combination with K97 or K98 Stainless steel screws and plates SPM bearing monitoring: Measuring nipple system 32 - thread M8, DE + NDE Documentation Terminal box drawing Inspection certificate 3.1 EN10204 (multi) Type test report (original motor) Docu-package NM2 (=U01+U04+U06+U15+U18+U40+U58) Languages for the main components (e.g. operating and maintenance instructions): Documentation German Documentation Czech (operation & safety instructions) Documentation Polish (operation & safety instructions) Documentation Russian (manual, datasheet, dimension drawing) Documentation Japanese (operation & safety instructions) Documentation Danish (operation & safety instructions) Documentation Rumanian (operation & safety instructions) Documentation Italian (operation & safety instructions) Documentation Finnish (operation & safety instructions) Documentation Dutch (operation & safety instructions) Documentation Turkish (operation & safety instructions) Documentation English Documentation French (operation & safety instructions) Documentation Spanish (operation & safety instructions) Documentation Portuguese (operation & safety instructions) Documentation Bulgarian (operation & safety instructions) Documentation Norwegian (operation & safety instructions) Documentation Hungarian (operation & safety instructions) Documentation Swedish (operation & safety instructions) Documentation Chinese simplified (operation & safety instructions) Documentation Serbian (operation & safety instructions) Frame size 71 80 90 K31 W47 Y80 ● and identification code Y82 ● and identification code Y84 M13 K51 K50 K99 K97 K98 L20 W71 G50 22,– 37,– o.MP. 22,– 37,– o.MP. 22,– 37,– o.MP. 100 22,– 37,– o.MP. 112 22,– 37,– o.MP. 132 22,– 37,– o.MP. 160 22,– 37,– o.MP. 70,– 85,– o.MP. 70,– 85,– o.MP. 70,– 85,– o.MP. 70,– 85,– o.MP. 70,– 85,– o.MP. 70,– 85,– o.MP. 70,– 85,– o.MP. 43,– 43,– 43,– 43,– 43,– 43,– 43,– 71,– 71,– 71,– 89,– 89,– 112,– 115,– 43,– 458,– 268,– 295,– 43,– 458,– 268,– 295,– 43,– 458,– 268,– 295,– 43,– 512,– 294,– 323,– 43,– 545,– 294,– 323,– 43,– 569,– 294,– 323,– 43,– 800,– 294,– 323,– 71,– 891,– 364,– 401,– 71,– 979,– 364,– 401,– 71,– 1.120,– 364,– 401,– 89,– 1.240,– 364,– 401,– 89,– 1.400,– 364,– 401,– 112,– 1.400,– 476,– 523,– 115,– 1.570,– 622,– 684,– □ □ □ □ □ □ □ □ □ N N N 160,– N N N N 170,– N N N N 185,– N N N N 224,– N N N N 242,– N N N N 307,– 478,– N N N 380,– 478,– N N N 413,– 478,– N N N 464,– 478,– N N N 500,– 478,– N N N 584,– 478,– N N N 738,– 478,– N N N 920,– 478,– N o.MP. o.MP. 2.930,– 1.150,– 621,– U08 U51 U52 U91 271,– 30,– 413,– 247,– 271,– 30,– 413,– 247,– 271,– 30,– 413,– 247,– 271,– 30,– 413,– 247,– 271,– 30,– 413,– 247,– 271,– 30,– 413,– 247,– 271,– 30,– 413,– 247,– 271,– 30,– 413,– 247,– 271,– 30,– 413,– 247,– 271,– 30,– 413,– 247,– 271,– 30,– 413,– 247,– 271,– 30,– 413,– 247,– 271,– 30,– 413,– 247,– 271,– 30,– 413,– 247,– D00 D54 D55 D56 D57 D62 D71 D72 D73 D74 D75 D76 D77 D78 D79 D80 D81 D82 D83 D84 D91 o.MP. 925,– 925,– 93,– 925,– 925,– 925,– o.MP. 925,– 93,– 925,– o.MP. o.MP. o.MP. 925,– 925,– 925,– 925,– 925,– 93,– 925,– o.MP. 925,– 925,– 93,– 925,– 925,– 925,– o.MP. 925,– 93,– 925,– o.MP. o.MP. o.MP. 925,– 925,– 925,– 925,– 925,– 93,– 925,– o.MP. 925,– 925,– 93,– 925,– 925,– 925,– o.MP. 925,– 93,– 925,– o.MP. o.MP. o.MP. 925,– 925,– 925,– 925,– 925,– 93,– 925,– o.MP. 925,– 925,– 93,– 925,– 925,– 925,– o.MP. 925,– 93,– 925,– o.MP. o.MP. o.MP. 925,– 925,– 925,– 925,– 925,– 93,– 925,– o.MP. 925,– 925,– 93,– 925,– 925,– 925,– o.MP. 925,– 93,– 925,– o.MP. o.MP. o.MP. 925,– 925,– 925,– 925,– 925,– 93,– 925,– o.MP. 925,– 925,– 93,– 925,– 925,– 925,– o.MP. 925,– 93,– 925,– o.MP. o.MP. o.MP. 925,– 925,– 925,– 925,– 925,– 93,– 925,– o.MP. 925,– 925,– 93,– 925,– 925,– 925,– o.MP. 925,– 93,– 925,– o.MP. o.MP. o.MP. 925,– 925,– 925,– 925,– 925,– 93,– 925,– o.MP. 925,– 925,– 93,– 925,– 925,– 925,– o.MP. 925,– 93,– 925,– o.MP. o.MP. o.MP. 925,– 925,– 925,– 925,– 925,– 93,– 925,– o.MP. 925,– 925,– 93,– 925,– 925,– 925,– o.MP. 925,– 93,– 925,– o.MP. o.MP. o.MP. 925,– 925,– 925,– 925,– 925,– 93,– 925,– o.MP. 925,– 925,– 93,– 925,– 925,– 925,– o.MP. 925,– 93,– 925,– o.MP. o.MP. o.MP. 925,– 925,– 925,– 925,– 925,– 93,– 925,– o.MP. 925,– 925,– 93,– 925,– 925,– 925,– o.MP. 925,– 93,– 925,– o.MP. o.MP. o.MP. 925,– 925,– 925,– 925,– 925,– 93,– 925,– o.MP. 925,– 925,– 93,– 925,– 925,– 925,– o.MP. 925,– 93,– 925,– o.MP. o.MP. o.MP. 925,– 925,– 925,– 925,– 925,– 93,– 925,– o.MP. 925,– 925,– 93,– 925,– 925,– 925,– o.MP. 925,– 93,– 925,– o.MP. o.MP. o.MP. 925,– 925,– 925,– 925,– 925,– 93,– 925,– o.MP. 925,– 925,– 93,– 925,– 925,– 925,– o.MP. 925,– 93,– 925,– o.MP. o.MP. o.MP. 925,– 925,– 925,– 925,– 925,– 93,– 925,– F00 □ □ □ □ □ □ □ 60,– 90,– 110,– 70,– 110,– 140,– 90,– 140,– 180,– □ 180 □ 200 □ 225 □ 250 280 315 355 Official EU languages (English/Spanish/French/Italian and German) are available for download. Please consult the factory for availability/delivery time/feasibility. Choose the required documents separately, e.g. U91 Test options Routine test according IEC without witness inspection (sine wave voltage) Extension of the liability for defects Extension of liability of defects of 12 to 24 months Extension of liability of defects of 18 to 30 months Extension of liability of defects of 24 to 36 months Q80 Q81 Q82 40,– 50,– 70,– 40,– 60,– 70,– 50,– 70,– 90,– □ = Standard version o.MP. = Without surcharge ● = This order code only determines the price of the version - additional plain text is required. a.A. = On request N = Not available Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version b. 19 140,– 220,– 280,– □ 190,– 290,– 370,– □ 240,– 380,– 480,– □ 310,– 480,– 620,– □ 390,– 600,– 770,– □ □ □ 540,– 830,– 1.070,– 990,– 1.520,– 1.970,– 2.070,– 3.190,– 4.130,– LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE2, 0,75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame size Prated 60Hz kW FS kW IE class Motor type Price for 1 unit for IM B3 Article No. Price for 1 unit for IM B3 2-pole: 3000 rpm at 50Hz 1) IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 1) 1PS50701PS50711PS50801PS50811PS50951PS50981PS51061PS51131PS51311PS51321PS51631PS51651PS51661PS51831PS52061PS52081PS52231PS52531PS52801PS52831PS53111PS53131PS53151PS53161PS53181PS53531PS53551PS5357- BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 -4AA3 1.850,– 1.920,– 1.980,– 2.160,– 2.350,– 2.750,– 3.080,– 3.560,– 4.250,– 5.160,– 6.480,– 7.870,– 8.800,– 9.780,– 12.200,– 14.400,– 16.400,– 19.200,– 25.000,– 28.600,– 34.300,– 39.200,– 46.900,– 56.600,– 69.900,– 88.500,– 101.000,– 128.000,– Price for 1 unit for IM B3, 50Hz, mains operation LOHER VARIO 400 355 L 450 450 355 L 500 450 400 L 500 500 400 L 560 560 400 L 630 630 400 L 710 630 450 L a.A. 710 450 L 710 800 450 L 800 900 450 L 900 1000 500 L a.A. 1200 500 L a.A. IIC DNSW…/1PS5… 1) DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) Enclosures Ex de II B / Ex d II B Ex de II C / Ex d II C Operating modes Mains-fed operation Converter-fed operation, standard insulation Converter-fed operation with special insulation (derating approx. 5 %) Mains-fed operation, pre-formed coil Converter-fed operation, pre-formed coil Voltages 690 VD , 50Hz 230 V/400 V, 50 Hz 500 VY, 50 Hz 500 VD , 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 For other types of construction see options list Frame size 355 ... 500 71 ... 500 -355LD-02 -355LX-02 -400LL-02 -400LN-02 -400LN-02 -400LX-02 -450LL-02 -450LL-02 -450LN-02 -450LN-02 -500LL-02 -500LN-02 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS L W 358358404405407408453455457458505508- BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ -4AA0 -4AA0 -4AA0 -4AA0 -4AA0 -4AA0 -4AA0 -4AA0 -4AA0 -4AA0 -4AA0 -4AA0 63.300,– 69.700,– 74.600,– 82.100,– 88.300,– 93.600,– 105.000,– 113.000,– 123.000,– 137.000,– 148.000,– 161.000,– Order code - 4 5 71 ... 450 (<=800kW) 71 ... 400 160 ... 500 0 1 2 - 450 (>800kW) ... 500 450 ... 500 3 4 - 355 ... 500 71 ... 112 71 ... 315 355 ... 450 71 ... 400 71 ... 400 71 ... 500 71 ... 500 71 ... 315 71 ... 112 71 ... 112 71 ... 400 71 ... 500 71 ... 500 1) Outside the IE code classification according to IEC60034-30. 2) Variant can be supplied as Ex nA, Loher type changes to ANGK…. 3) Direction of rotation must be specified (order code K97 or K98). … 0 1 3 5 6 8 9 0 1 2 3 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 20 … Discount level A DNGW-071BR-022) DNGW-071BS-022) DNGW-080BR-022) DNGW-080BS-022) DNGW-090LR-02 DNGW-090LS-02 DNGW-100LS-02 DNGW-112MS-02 DNGW-132SR-02 DNGW-132SS-02 DNGW-160MR-02 DNGW-160MS-02 DNGW-160LS-02 DNGW-180MS-02 DNGW-200LR-02 DNGW-200LS-02 DNGW-225MS-02 DNGW-250MM-02 DNGW-280SL-02 DNGW-280MM-02 DNGW-315SL-02 DNGW-315ML-02 DNGW-315MN-02 DNGW-315LL-02 DNGW-315LN-02 DNGW-355MR-023) DNGW-355MS-023) DNGW-355MT-023) 1) Price for 1 unit for IM B3, 50Hz, mains operation IIB DNSL…/1PS4… 58.900,– 64.900,– 69.400,– 76.400,– 82.100,– 87.100,– 97.400,– 105.000,– 114.000,– 128.000,– 138.000,– 150.000,– Options acc. surcharge price list 1PS4… / 1PS5… IIC DNGW…/1PS5… Discount level C LOHER CHEMSTAR 0,37 71 B 0,44 0,55 71 B 0,66 0,75 80 B 0,9 1,1 80 B 1,2 1,5 90 L 1,8 2,2 90 L 2,6 3 100 L 3,6 4 112 M 4,5 5,5 132 S 6,6 7,5 132 S 9 11 160 M 13,2 15 160 M 18 18,5 160 L 22 22 180 M 26 30 200 L 36 37 200 L 44 45 225 M 54 55 250 M 66 75 280 S 90 90 280 M 110 110 315 S 125 132 315 M 145 160 315 M 180 200 315 L 220 250 315 L 270 315 355 M a.A. 360 355 M a.A. 460 355 M a.A. LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE2, 0,75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame Prated size 60Hz kW FS IE class Article No. Motor type Price for 1 unit for IM B3 Price for 1 unit for IM B3 kW 4-pole: 1500 rpm at 50Hz LOHER VARIO 400 355 L 450 450 355 L 500 500 355 L 560 500 400 L 560 560 400 L 630 630 400 L 710 710 400 L 800 800 450 L 900 900 450 L 1000 950 450 L a.A. 1000 500 L a.A. 1120 500 L a.A. 1250 500 L a.A. 1400 500 L a.A. 1) 1) IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 1) 2) DNGW-071BR-04 2) DNGW-071BS-04 2) DNGW-080BR-04 2) DNGW-080BS-04 DNGW-090LR-04 DNGW-090LS-04 DNGW-100LR-04 DNGW-100LS-04 DNGW-112MS-04 DNGW-132SR-04 DNGW-132MS-04 DNGW-160MR-04 DNGW-160LS-04 DNGW-180MR-04 DNGW-180LS-04 DNGW-200LS-04 DNGW-225SR-04 DNGW-225MS-04 DNGW-250MM-04 DNGW-280SL-04 DNGW-280MM-04 DNGW-315SL-04 DNGW-315ML-04 DNGW-315MN-04 DNGW-315LL-04 DNGW-315LM-04 3) DNGW-355MR-04 3) DNGW-355MS-04 DNGW-355MT-04 3) 1PS50701PS50711PS50801PS50811PS50951PS50981PS51061PS51081PS51131PS51311PS51331PS51631PS51661PS51831PS51861PS52061PS52201PS52231PS52531PS52801PS52831PS53111PS53131PS53151PS53161PS53171PS53531PS53551PS5357- BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 1.730,– 1.790,– 1.860,– 1.920,– 2.100,– 2.280,– 2.670,– 2.980,– 3.450,– 4.120,– 5.000,– 6.280,– 7.630,– 8.530,– 9.470,– 11.800,– 14.000,– 15.900,– 18.600,– 24.100,– 27.500,– 33.000,– 37.600,– 44.900,– 54.100,– 66.500,– 83.700,– 95.300,– 119.000,– Discount level A 1) Price for 1 unit Price for 1 unit for IM B3, 50Hz, for IM B3, 50Hz, mains operation mains operation IIC IIB DNSW…/1PS5… DNSL…/1PS4… 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS -355LD-04 -355LN-04 -355LX-04 -400LL-04 -400LN-04 -400LN-04 -400LX-04 -450LL-04 -450LN-04 -450LN-04 -500LL-04 -500LL-04 4) -500LN-04 -500LN-04 Enclosures Frame size Ex de II B / Ex d II B 355 ... 500 L Ex de II C / Ex d II C 71 ... 500 W Operating modes Mains-fed operation 71 ... 450 (<=800kW) 71 ... 400 Converter-fed operation, standard insulation Converter-fed operation with special insulation 160 ... 500 (derating approx. 5 %) Mains-fed operation, pre-formed coil 450 (>800kW) ... 500 Converter-fed operation, pre-formed coil 450 ... 500 Voltages 690 VD , 50Hz 355 ... 500 230 V/400 V, 50 Hz 71 ... 112 500 VY, 50 Hz 71 ... 315 500 VD , 50 Hz 355 ... 450 400 V/690 V, 50 Hz 71 ... 400 690 VY, 50 Hz 71 ... 400 For other voltages see options list 71 ... 500 Types of construction IM B3 71 ... 500 IM B5 71 ... 315 IM B34 71 ... 112 IM B14 71 ... 112 IM V1/canopy 71 ... 400 IM B35 71 ... 500 71 ... 500 For other types of construction see options list 1) Outside the IE code classification according to IEC60034-30. 2) Variant can be supplied as Ex nA, Loher type changes to ANGK…. 3) Direction of rotation must be specified (order code K97 or K98). 4) 6-phase Motor 2x690V 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 350357358404405407408455457458504505507508- BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ -4BA0 -4BA0 -4BA0 -4BA0 -4BA0 -4BA0 -4BA0 -4BA0 -4BA0 -4BA0 -4BA0 -4BA0 -4BA0 -4BA0 62.500,– 69.600,– 76.100,– 82.900,– 86.700,– 95.200,– 103.000,– 112.000,– 120.000,– 126.000,– 140.000,– 154.000,– 182.000,– 171.000,– Order code - 4 5 0 1 2 - 3 4 … 0 1 3 5 6 8 9 0 1 2 3 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 21 … 58.100,– 64.800,– 70.800,– 77.100,– 80.700,– 88.500,– 96.200,– 104.000,– 111.000,– 117.000,– 131.000,– 143.000,– 169.000,– 159.000,– Options acc. surcharge price list 1PS4… / 1PS5… IIC DNGW…/1PS5… Discount level C LOHER CHEMSTAR 0,25 71 B 0,3 0,37 71 B 0,44 0,55 80 B 0,66 0,75 80 B 0,9 1,1 90 L 1,3 1,5 90 L 1,8 2,2 100 L 2,6 3 100 L 3,6 4 112 M 4,8 5,5 132 S 6,6 7,5 132 M 9 11 160 M 13 15 160 L 18 18,5 180 M 22 22 180 L 26 30 200 L 36 37 225 S 44 45 225 M 54 55 250 M 66 75 280 S 90 90 280 M 110 110 315 S 125 132 315 M 145 160 315 M 180 200 315 L 220 250 315 L 270 315 355 M a.A. 360 355 M a.A. 460 355 M a.A. LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE2, 0,75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame size Prated 60Hz kW FS kW IE class Motor type Article No. Price for 1 unit for IM B3 Price for 1 unit for IM B3 6-pole: 1000 rpm at 50Hz 1) 1) IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 1PS50711PS50801PS50811PS50951PS50981PS51061PS51131PS51311PS51331PS51351PS51631PS51661PS51861PS52061PS52081PS52231PS52531PS52801PS52831PS53111PS53131PS53141PS53151PS53161PS53171PS53531PS53551PS5357- BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 1.900,– 1.970,– 2.030,– 2.220,– 2.400,– 2.820,– 3.740,– 4.480,– 5.400,– 6.030,– 6.660,– 8.040,– 9.950,– 11.200,– 12.300,– 16.600,– 19.400,– 25.000,– 28.500,– 34.100,– 38.900,– 42.600,– 46.300,– 55.700,– 68.500,– 86.200,– 98.200,– 122.000,– Price for 1 unit for IM B3, 50Hz, mains operation LOHER VARIO 315 355 L 355 355 355 L 400 400 355 L 450 400 400 L 450 450 400 L 500 500 400 L 560 560 450 L 630 630 450 L 710 710 450 L 800 800 450 L 900 900 500 L 1000 1000 500 L 1120 1120 500 L 1250 IIC DNSW…/1PS5… IE2 IE2 DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) Enclosures Ex de II B / Ex d II B Ex de II C / Ex d II C Operating modes Mains-fed operation Converter-fed operation, standard insulation Converter-fed operation with special insulation (derating approx. 5 %) Mains-fed operation, pre-formed coil Converter-fed operation, pre-formed coil Voltages 690 VD , 50Hz 230 V/400 V, 50 Hz 500 VY, 50 Hz 500 VD , 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 For other types of construction see options list Frame size 355 ... 500 71 ... 500 -355LD-06 -355LN-06 -355LN-06 -400LL-06 -400LN-06 -400LN-06 -450LL-06 -450LL-06 -450LN-06 -450LN-06 -500LL-06 -500LN-06 -500LN-06 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS L W 358357358404405407453455457458505507508- BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ -4CA0 -4CA0 -4CA0 -4CA0 -4CA0 -4CA0 -4CA0 -4CA0 -4CA0 -4CA0 -4CA0 -4CA0 -4CA0 68.800,– 80.500,– 84.000,– 88.900,– 92.500,– 101.000,– 108.000,– 114.000,– 121.000,– 132.000,– 156.000,– 166.000,– 175.000,– Order code - 4 5 71 ... 450 71 ... 450 160 ... 500 0 1 2 - 500 ... 500 450 ... 500 3 4 - 355 ... 500 71 ... 112 71 ... 315 355 ... 450 71 ... 400 71 ... 400 71 ... 500 71 ... 500 71 ... 315 71 ... 112 71 ... 112 71 ... 450 71 ... 500 71 ... 500 1) Outside the IE code classification according to IEC60034-30. 2) Variant can be supplied as Ex nA, Loher type changes to ANGK…. … 0 1 3 5 6 8 9 0 1 2 3 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 22 … Discount level A DNGW-071BS-062) DNGW-080BR-062) DNGW-080BS-062) DNGW-090LR-06 DNGW-090LS-06 DNGW-100LS-06 DNGW-112MS-06 DNGW-132SR-06 DNGW-132MR-06 DNGW-132MS-06 DNGW-160MR-06 DNGW-160LS-06 DNGW-180LS-06 DNGW-200LR-06 DNGW-200LS-06 DNGW-225MS-06 DNGW-250MM-06 DNGW-280SL-06 DNGW-280MM-06 DNGW-315SL-06 DNGW-315ML-06 DNGW-315MM-06 DNGW-315MN-06 DNGW-315LL-06 DNGW-315LM-06 DNGW-355MR-06 DNGW-355MS-06 DNGW-355MT-06 1) Price for 1 unit for IM B3, 50Hz, mains operation IIB DNSL…/1PS4… 64.000,– 74.900,– 78.100,– 82.700,– 86.100,– 93.600,– 101.000,– 106.000,– 112.000,– 122.000,– 145.000,– 154.000,– 163.000,– Options acc. surcharge price list 1PS4… / 1PS5… IIC DNGW…/1PS5… Discount level C LOHER CHEMSTAR 0,25 71 B 0,3 0,37 80 B 0,44 0,55 80 B 0,66 0,75 90 L 0,75 1,1 90 L 0,9 1,5 100 L 1,25 2,2 112 M 1,8 3 132 S 3 4 132 M 4 5,5 132 M 5,5 7,5 160 M 7,5 11 160 L 11 15 180 L 15 18,5 200 L 18,5 22 200 L 22 30 225 M 30 37 250 M 37 45 280 S 45 55 280 M 55 75 315 S 75 90 315 M 90 110 315 M 110 132 315 M 132 160 315 L 160 200 315 L 200 280 355 M a.A. 315 355 M a.A. 360 355 M a.A. LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame size Prated 60Hz kW FS kW IE class Article No. Motor type Price for 1 unit for IM B3 Price for 1 unit for IM B3 8-pole: 750 rpm at 50Hz 1) DNGW-090LR-08 DNGW-090LS-08 DNGW-100LR-08 DNGW-100LS-08 DNGW-112MS-08 DNGW-132SR-08 DNGW-132MR-08 DNGW-160MR-08 DNGW-160MS-08 DNGW-160LS-08 DNGW-180LS-08 DNGW-200LR-08 DNGW-225SR-08 DNGW-225MS-08 DNGW-250MM-08 DNGW-280SL-08 DNGW-280MM-08 DNGW-315SL-08 DNGW-315ML-08 DNGW-315MM-08 DNGW-315MN-08 3) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) DNGW-315LL-08 DNGW-315LM-08 3) 1) 1PS50711PS50811PS50951PS50981PS51061PS51081PS51131PS51311PS51331PS51631PS51651PS51661PS51861PS52061PS52201PS52231PS52531PS52801PS52831PS53111PS53131PS53141PS53151PS53161PS5317- BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 -4DA3 1.960,– 2.090,– 2.260,– 2.490,– 2.810,– 3.240,– 3.810,– 4.610,– 5.590,– 6.980,– 8.180,– 8.750,– 10.200,– 12.600,– 15.000,– 16.900,– 19.700,– 25.500,– 29.000,– 34.600,– 39.400,– 46.800,– 56.400,– 69.200,– 87.000,– Price for 1 unit for IM B3, 50Hz, mains operation LOHER VARIO 200 355 L 225 225 355 L 250 250 355 L 280 280 355 L 315 315 355 L 355 355 400 L 400 400 400 L 450 450 400 L 500 500 450 L 560 560 450 L 630 630 450 L 710 670 450 L 750 710 500 L 800 800 500 L 900 900 500 L 1000 950 500 L 1050 IIC DNSW…/1PS5… 1) DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) Enclosures Ex de II B / Ex d II B Ex de II C / Ex d II C Operating modes Mains-fed operation Converter-fed operation, standard insulation Converter-fed operation with special insulation (derating approx. 5 %) Mains-fed operation, pre-formed coil Converter-fed operation, pre-formed coil Voltages 690 VD , 50Hz 230 V/400 V, 50 Hz 500 VY, 50 Hz 500 VD , 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 For other types of construction see options list Frame size 355 ... 500 71 ... 500 L W -355LB-08 -355LC-08 -355LD-08 -355LN-08 -355LX-08 -400LL-08 -400LN-08 -400LX-08 -450LL-08 -450LN-08 -450LN-08 -450LX-08 -500LL-08 -500LL-08 -500LN-08 -500LX-08 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 356357358357358404407408455457458450504505507508- BH BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ -4DA0 -4DA0 -4DA0 -4DA0 -4DA0 -4DA0 -4DA0 -4DA0 -4DA0 -4DA0 -4DA0 -4DA0 -4DA0 -4DA0 -4DA0 -4DA0 63.000,– 64.400,– 70.400,– 83.400,– 86.100,– 88.900,– 96.400,– 104.000,– 115.000,– 123.000,– 132.000,– 137.000,– 157.000,– 166.000,– 174.000,– 184.000,– Order code - 4 5 71 ... 450 71 ... 450 160 ... 500 0 1 2 - 500 500 3 4 - 355 ... 500 71 ... 112 71 ... 315 355 ... 450 71 ... 400 71 ... 400 71 ... 500 71 ... 500 71 ... 315 71 ... 112 71 ... 112 71 ... 450 71 ... 500 71 ... 500 1) Outside the IE code classification according to IEC60034-30. 2) Variant can be supplied as Ex nA, Loher type changes to ANGK…. 3) Rated output, partial utilization up to 155°C (F). … 0 1 3 5 6 8 9 0 1 2 3 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 23 … Discount level A DNGW-071BS-08 DNGW-080BS-08 2) 1) Price for 1 unit for IM B3, 50Hz, mains operation IIB DNSL…/1PS4… 58.700,– 59.900,– 65.500,– 77.600,– 80.100,– 82.700,– 89.700,– 97.000,– 107.000,– 114.000,– 122.000,– 128.000,– 146.000,– 154.000,– 162.000,– 171.000,– Options acc. surcharge price list 1PS4… / 1PS5… IIC DNGW…/1PS5… 2) 1) Discount level C LOHER CHEMSTAR 0,12 71 B a.A. 0,25 80 B a.A. 0,37 90 L a.A. 0,55 90 L a.A. 0,75 100 L a.A. 1,1 100 L a.A. 1,5 112 M a.A. 2,2 132 S a.A. 3 132 M a.A. 4 160 M a.A. 5,5 160 M a.A. 7,5 160 L a.A. 11 180 L a.A. 15 200 L a.A. 18,5 225 S a.A. 22 225 M a.A. 30 250 M a.A. 37 280 S a.A. 45 280 M a.A. 55 315 S a.A. 75 315 M a.A. 90 315 M a.A. 110 315 M a.A. 132 315 L a.A. 160 315 L a.A. LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame size Prated 60Hz kW FS kW IE class Article No. Motor type Price for 1 unit for IM B3, 50Hz, mains operation Price for 1 unit for IM B3, 50Hz, mains operation 10-pole: 600 rpm at 50Hz LOHER CHEMSTAR on request -355LB-10 -355LC-10 -355LD-10 -355LX-10 -400LL-10 -400LN-10 -400LN-10 -400LX-10 -450LL-10 -450LN-10 -450LN-10 -450LX-10 -500LL-10 -500LN-10 -500LN-10 -500LX-10 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 356357358358404405407408454455457458504505507508- BH BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ -4EA0 -4EA0 -4EA0 -4EA0 -4EA0 -4EA0 -4EA0 -4EA0 -4EA0 -4EA0 -4EA0 -4EA0 -4EA0 -4EA0 -4EA0 -4EA0 68.600,– 70.100,– 75.000,– 82.300,– 88.800,– 93.000,– 98.200,– 110.000,– 121.000,– 128.000,– 136.000,– 143.000,– 159.000,– 168.000,– 177.000,– 185.000,– 1) DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) Frame size 355 ... 500 355 ... 500 -355LB-12 -355LC-12 -355LD-12 -355LX-12 -400LL-12 -400LN-12 -400LN-12 -400LX-12 -450LL-12 -450LN-12 -450LN-12 -450LX-12 -500LL-12 -500LN-12 -500LN-12 -500LX-12 L W 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 356357358358404405407408454455457458504505507508- BH BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ -4FA0 -4FA0 -4FA0 -4FA0 -4FA0 -4FA0 -4FA0 -4FA0 -4FA0 -4FA0 -4FA0 -4FA0 -4FA0 -4FA0 -4FA0 -4FA0 69.100,– 70.000,– 75.900,– 83.000,– 89.400,– 93.400,– 98.900,– 111.000,– 121.000,– 129.000,– 138.000,– 145.000,– 162.000,– 171.000,– 180.000,– 190.000,– Order code - 4 5 355 ... 450 355 ... 450 355 ... 500 0 1 2 - 500 500 3 4 - 355 ... 500 355 ... 450 355 ... 400 355 ... 400 355 ... 500 … 0 5 6 8 9 355 ... 500 355 ... 450 355 ... 500 355 ... 500 0 4 6 9 Outside the IE code classification according to IEC60034-30. Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 24 … 63.900,– 65.200,– 69.800,– 76.600,– 82.600,– 86.500,– 91.400,– 102.000,– 112.000,– 119.000,– 126.000,– 133.000,– 148.000,– 156.000,– 164.000,– 172.000,– Discount level C IIC DNSW…/1PS5… Enclosures Ex de II B / Ex d II B Ex de II C / Ex d II C Operating modes Mains-fed operation Converter-fed operation, standard insulation Converter-fed operation with special insulation (derating approx. 5 %) Mains-fed operation, pre-formed coil Converter-fed operation, pre-formed coil Voltages 690 VD , 50Hz 500 VD , 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM V1/canopy IM B35 For other types of construction see options list 1) IIB DNSL…/1PS4… 64.300,– 65.100,– 70.600,– 77.200,– 83.100,– 86.900,– 92.000,– 103.000,– 112.000,– 120.000,– 129.000,– 135.000,– 151.000,– 159.000,– 167.000,– 176.000,– Options acc. surcharge price list 1PS4… / 1PS5… LOHER VARIO 140 355 L 160 160 355 L 180 180 355 L 200 190 355 L 215 200 400 L 225 225 400 L 250 250 400 L 280 280 400 L 315 315 450 L 355 355 450 L 400 400 450 L 450 420 450 L 475 450 500 L 500 500 500 L 560 560 500 L 630 600 500 L 650 DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS IIB DNSL…/1PS4… Discount level C IIC DNSW…/1PS5… LOHER VARIO 1) 160 355 L 180 1) 180 355 L 200 1) 200 355 L 225 1) 225 355 L 250 1) 250 400 L 280 1) 280 400 L 315 1) 315 400 L 355 1) 355 400 L 400 1) 400 450 L 450 1) 450 450 L 500 1) 500 450 L 560 1) 520 450 L 585 1) 560 500 L 630 1) 630 500 L 710 1) 670 500 L 750 1) 750 500 L 800 12-pole: 500 rpm at 50Hz LOHER CHEMSTAR on request LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame size Prated 60Hz kW FS kW Article No. Motor type Price for 1 unit for IM B3, 50Hz, mains operation Price for 1 unit for IM B3, 50Hz, mains operation 14-pole: 430 rpm at 50Hz LOHER CHEMSTAR on request -355LB-14 -355LC-14 -355LD-14 -400LL-14 -400LN-14 -400LN-14 -400LX-14 -450LL-14 -450LN-14 -450LN-14 -450LX-14 -500LL-14 -500LN-14 -500LN-14 -500LX-14 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 356357358404405407408454455457458504505507508- BH BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ -4GA0 -4GA0 -4GA0 -4GA0 -4GA0 -4GA0 -4GA0 -4GA0 -4GA0 -4GA0 -4GA0 -4GA0 -4GA0 -4GA0 -4GA0 70.100,– 72.000,– 78.300,– 85.400,– 92.100,– 96.300,– 102.000,– 118.000,– 128.000,– 138.000,– 146.000,– 166.000,– 174.000,– 184.000,– 193.000,– DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS Frame size 355 ... 500 355 ... 500 -355LB-16 -355LC-16 -355LD-16 -400LL-16 -400LN-16 -400LX-16 -450LL-16 -450LN-16 -450LN-16 -450LX-16 -500LL-16 -500LN-16 -500LN-16 -500LX-16 L W 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 1PS 356357358405407408454455457458504505507508- BH BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ -4HA0 -4HA0 -4HA0 -4HA0 -4HA0 -4HA0 -4HA0 -4HA0 -4HA0 -4HA0 -4HA0 -4HA0 -4HA0 -4HA0 70.100,– 73.200,– 79.400,– 90.000,– 97.700,– 101.000,– 116.000,– 129.000,– 137.000,– 145.000,– 168.000,– 173.000,– 183.000,– 192.000,– Order code - 4 5 355 ... 450 355 ... 450 355 ... 500 0 1 2 - 500 500 3 4 - 355 ... 500 355 ... 450 355 ... 400 355 ... 400 355 ... 500 … 0 5 6 8 9 355 ... 500 355 ... 450 355 ... 500 355 ... 500 0 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 25 … 65.200,– 67.000,– 72.800,– 79.500,– 85.700,– 89.600,– 94.800,– 110.000,– 119.000,– 129.000,– 136.000,– 154.000,– 162.000,– 171.000,– 180.000,– Discount level C IIC DNSW…/1PS5… LOHER VARIO 90 355 L 100 100 355 L 115 110 355 L 125 132 400 L 160 160 400 L 180 180 400 L 200 200 450 L 225 225 450 L 250 250 450 L 280 265 450 L 300 280 500 L 315 315 500 L 355 355 500 L 400 400 500 L 450 Enclosures Ex de II B / Ex d II B Ex de II C / Ex d II C Operating modes Mains-fed operation Converter-fed operation, standard insulation Converter-fed operation with special insulation (derating approx. 5 %) Mains-fed operation, pre-formed coil Converter-fed operation, pre-formed coil Voltages 690 VD , 50Hz 500 VD , 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM V1/canopy IM B35 For other types of construction see options list IIB DNSL…/1PS4… 65.200,– 68.100,– 73.800,– 83.700,– 90.900,– 93.900,– 108.000,– 120.000,– 128.000,– 135.000,– 156.000,– 161.000,– 170.000,– 179.000,– Options acc. surcharge price list 1PS4… / 1PS5… DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS DNS IIB DNSL…/1PS4… Discount level C IIC DNSW…/1PS5… LOHER VARIO 110 355 L 132 125 355 L 140 140 355 L 160 160 400 L 180 180 400 L 200 200 400 L 225 225 400 L 250 250 450 L 280 280 450 L 315 315 450 L 355 340 450 L 380 355 500 L 400 400 500 L 450 450 500 L 500 500 500 L 560 16-pole: 375 rpm at 50Hz LOHER CHEMSTAR on request LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Pole-changing motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Mains-fed operation: double pole-changing for constant load torque · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame size Prated 60Hz kW FS kW Motor type Article No. Price for 1 unit for IM B3 Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 230 V, 50 Hz 500 V, 50 Hz 400 V, 50 Hz 690 V, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 For other types of construction see options list 1) Rated output, partial utilization up to 155°C (F). DNGW-080BS-42 DNGW-090LS-42 DNGW-100LR-42 DNGW-100LS-42 1) DNGW-112MS-42 1) DNGW-132SR-42 DNGW-132MR-42 DNGW-160MR-42 DNGW-160LS-42 DNGW-180MR-42 DNGW-180LS-42 DNGW-200LS-42 DNGW-225SR-42 DNGW-225MS-42 DNGW-250MM-42 DNGW-280SL-42 DNGW-280MM-42 DNGW-315SL-42 DNGW-315ML-42 DNGW-315MN-42 DNGW-315LL-42 DNGW-315LM-42 1PS50811PS50981PS51061PS51081PS51131PS51311PS51331PS51631PS51661PS51831PS51861PS52061PS52201PS52231PS52531PS52801PS52831PS53111PS53131PS53151PS53161PS5317- Frame size 80 ... 315 80 ... 315 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD … 1 3 6 8 9 80 ... 315 80 ... 315 80 ... 112 80 ... 112 80 ... 315 80 ... 315 80 ... 315 0 1 2 3 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 26 2.780,– 3.280,– 3.810,– 4.220,– 4.840,– 5.730,– 6.890,– 8.580,– 10.300,– 11.500,– 12.600,– 15.600,– 18.300,– 20.600,– 23.900,– 30.600,– 34.600,– 41.200,– 46.500,– 54.900,– 65.600,– 79.800,– Order code - 0 1 80 ... 112 80 ... 315 80 ... 315 80 ... 315 80 ... 315 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 … Discount level A IIC DNGW…/1PS5… LOHER CHEMSTAR 0,65/0,85 80 B a.A. 1,45/1,9 90 L a.A. 2/2,4 100 L a.A. 2,6/3,2 100 L a.A. 3,6/4,3 112 M a.A. 4,9/6 132 S a.A. 6,5/9 132 M a.A. 9/11 160 M a.A. 13/16 160 L a.A. 16,5/20 180 M a.A. 18,5/25 180 L a.A. 26/31 200 L a.A. 32/38 225 S a.A. 38/46 225 M a.A. 45/55 250 M a.A. 60/75 280 S a.A. 73/90 280 M a.A. 82/96 315 S a.A. 100/124 315 M a.A. 120/145 315 M a.A. 142/172 315 L a.A. 150/200 315 L a.A. LOHER VARIO on request Options acc. surcharge price list 1PS4… / 1PS5… 4-/2-pole: 1500/3000 rpm at 50Hz with 1 winding in Dahlander connection LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Pole-changing motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Mains-fed operation: double pole-changing for constant load torque · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame size Prated 60Hz kW FS kW Motor type Article No. Price for 1 unit for IM B3 Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 230 V, 50 Hz 500 V, 50 Hz 400 V, 50 Hz 690 V, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 For other types of construction see options list 1) Rated output, partial utilization up to 155°C (F). DNGW-090LS-84 DNGW-100LR-84 DNGW-100LS-84 DNGW-112MS-84 DNGW-132SR-84 DNGW-132MR-84 DNGW-160MR-84 DNGW-160MS-84 DNGW-160LS-84 1) DNGW-180LS-84 DNGW-200LR-84 1) DNGW-225SR-84 1) DNGW-225MS-84 DNGW-250MM-84 DNGW-280SL-84 1) DNGW-280MM-84 DNGW-315SL-84 DNGW-315ML-84 DNGW-315MN-84 1) DNGW-315LL-84 1) DNGW-315LM-84 1PS50981PS51061PS51081PS51131PS51311PS51331PS51631PS51651PS51661PS51861PS52061PS52201PS52231PS52531PS52801PS52831PS53111PS53131PS53151PS53161PS5317- Frame size 90 ... 315 90 ... 315 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD … 1 3 6 8 9 90 ... 315 90 ... 315 90 ... 112 90 ... 112 90 ... 315 90 ... 315 90 ... 315 0 1 2 3 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 27 3.350,– 3.890,– 4.310,– 4.940,– 5.850,– 7.040,– 7.860,– 8.680,– 10.500,– 12.900,– 15.900,– 18.700,– 21.000,– 24.300,– 31.200,– 35.300,– 41.900,– 47.300,– 55.900,– 66.700,– 81.100,– Order code - 0 1 90 ... 112 90 ... 315 90 ... 315 90 ... 315 90 ... 315 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 … Discount level A IIC DNGW…/1PS5… LOHER CHEMSTAR 0,5/0,8 90 L a.A. 0,9/1,3 100 L a.A. 1/1,6 100 L a.A. 1,4/2,2 112 M a.A. 2,3/3,4 132 S a.A. 3/5 132 M a.A. 4/5,5 160 M a.A. 5/7,5 160 M a.A. 7/11 160 L a.A. 11/18 180 L a.A. 17/25 200 L a.A. 22/31 225 S a.A. 26/38 225 M a.A. 32/46 250 M a.A. 42/60 280 S a.A. 50/72 280 M a.A. 60/83 315 S a.A. 72/110 315 M a.A. 90/132 315 M a.A. 115/160 315 L a.A. 145/220 315 L a.A. LOHER VARIO on request Options acc. surcharge price list 1PS4… / 1PS5… 8-/4-pole: 750/1500 rpm at 50Hz with 1 winding in Dahlander connection LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Pole-changing motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Mains-fed operation: double pole-changing for constant load torque · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame size Prated 60Hz kW FS kW Motor type Article No. Price for 1 unit for IM B3 Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 230 V, 50 Hz 500 V, 50 Hz 400 V, 50 Hz 690 V, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 For other types of construction see options list 1) Rated output, partial utilization up to 155°C (F). DNGW-090LS-64 DNGW-100LR-64 DNGW-100LS-64 DNGW-112MS-64 DNGW-132SR-64 DNGW-132MR-64 DNGW-160MR-64 DNGW-160LS-64 DNGW-180LS-64 DNGW-200LR-64 DNGW-200LS-64 DNGW-225SR-64 DNGW-225MS-64 DNGW-250MM-64 DNGW-280SL-64 DNGW-280MM-64 DNGW-315SL-64 1) DNGW-315ML-64 DNGW-315MN-64 1) DNGW-315LL-64 1) DNGW-315LM-64 1PS50981PS51061PS51081PS51131PS51311PS51331PS51631PS51661PS51861PS52061PS52081PS52201PS52231PS52531PS52801PS52831PS53111PS53131PS53151PS53161PS5317- Frame size 90 ... 315 90 ... 315 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD … 1 3 6 8 9 90 ... 315 90 ... 315 90 ... 112 90 ... 112 90 ... 315 90 ... 315 90 ... 315 0 1 2 3 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 28 3.420,– 3.970,– 4.400,– 5.050,– 5.970,– 7.190,– 8.950,– 10.800,– 13.300,– 14.700,– 16.200,– 19.100,– 21.500,– 24.900,– 31.900,– 36.100,– 42.900,– 48.400,– 57.200,– 68.300,– 83.100,– Order code - 0 1 90 ... 112 90 ... 315 90 ... 315 90 ... 315 90 ... 315 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 … Discount level A IIC DNGW…/1PS5… LOHER CHEMSTAR 0,6/0,9 90 L a.A. 0,9/1,3 100 L a.A. 1,1/1,5 100 L a.A. 1,5/2,2 112 M a.A. 2,2/3,3 132 S a.A. 3/4,5 132 M a.A. 4,5/6,5 160 M a.A. 6,5/9,5 160 L a.A. 11/16 180 L a.A. 13/19 200 L a.A. 15/23 200 L a.A. 18/27 225 S a.A. 21/31 225 M a.A. 28/40 250 M a.A. 43/65 280 S a.A. 52/78 280 M a.A. 60/90 315 S a.A. 70/100 315 M a.A. 80/115 315 M a.A. 100/140 315 L a.A. 125/180 315 L a.A. LOHER VARIO on request Options acc. surcharge price list 1PS4… / 1PS5… 6-/4-pole: 1000/1500 rpm at 50Hz with 2 separate windings LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Pole-changing motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Mains-fed operation: double pole-changing for constant load torque · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame size Prated 60Hz kW FS kW Motor type Price for 1 unit for IM B3 Article No. Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 230 V, 50 Hz 500 V, 50 Hz 400 V, 50 Hz 690 V, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 For other types of construction see options list 1) Rated output, partial utilization up to 155°C (F). DNGW-090LS-86 DNGW-100LR-86 DNGW-100LS-86 DNGW-112MS-86 DNGW-132SR-86 DNGW-132MR-86 DNGW-160MR-86 DNGW-160LS-86 DNGW-180LS-86 1) DNGW-200LR-86 DNGW-225SR-86 DNGW-225MS-86 DNGW-250MM-86 DNGW-280SL-86 DNGW-280MM-86 1) DNGW-315SL-86 1) DNGW-315ML-86 1) DNGW-315MN-86 1) DNGW-315LL-86 1) DNGW-315LM-86 1PS50981PS51061PS51081PS51131PS51311PS51331PS51631PS51661PS51861PS52061PS52201PS52231PS52531PS52801PS52831PS53111PS53131PS53151PS53161PS5317- Frame size 90 ... 315 90 ... 315 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD … 1 3 6 8 9 90 ... 315 90 ... 315 90 ... 112 90 ... 112 90 ... 315 90 ... 315 90 ... 315 0 1 2 3 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 29 3.470,– 4.020,– 4.450,– 5.110,– 6.050,– 7.270,– 9.050,– 10.900,– 13.400,– 16.500,– 19.400,– 21.900,– 25.300,– 32.500,– 36.700,– 43.600,– 49.200,– 58.200,– 69.400,– 84.500,– Order code - 0 1 90 ... 112 90 ... 315 90 ... 315 90 ... 315 90 ... 315 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 … Discount level A IIC DNGW…/1PS5… LOHER CHEMSTAR 0,45/0,6 90 L a.A. 0,6/0,8 100 L a.A. 0,7/0,9 100 L a.A. 0,9/1,4 112 M a.A. 1,5/2 132 S a.A. 2,2/3 132 M a.A. 4/5,5 160 M a.A. 5,5/7,5 160 L a.A. 8,5/11 180 L a.A. 14,5/19 200 L a.A. 16/21 225 S a.A. 19/25 225 M a.A. 24/32 250 M a.A. 33/44 280 S a.A. 40/53 280 M a.A. 50/65 315 S a.A. 60/80 315 M a.A. 70/95 315 M a.A. 80/110 315 L a.A. 115/150 315 L a.A. LOHER VARIO on request Options acc. surcharge price list 1PS4… / 1PS5… 8-/6-pole: 750/1000 rpm at 50Hz with 2 separate windings LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Pole-changing motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Mains-fed operation: double pole-changing for square-law load torque · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame size Prated 60Hz kW FS kW Motor type Article No. Price for 1 unit for IM B3 Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 230 V, 50 Hz 500 V, 50 Hz 400 V, 50 Hz 690 V, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 For other types of construction see options list 1) Rated output, partial utilization up to 155°C (F). DVGW-080BS-42 DVGW-090LS-42 DVGW-100LR-42 DVGW-100LS-42 DVGW-112MS-42 DVGW-132SR-42 DVGW-132MR-42 DVGW-160MR-42 DVGW-160LS-42 DVGW-180MR-42 1) DVGW-180LS-42 DVGW-200LS-42 DVGW-225SR-42 DVGW-225MS-42 DVGW-250MM-42 DVGW-280SL-42 DVGW-280MM-42 DVGW-315SL-42 DVGW-315ML-42 DVGW-315MN-42 DVGW-315LL-42 DVGW-315LM-42 1PS50811PS50981PS51061PS51081PS51131PS51311PS51331PS51631PS51661PS51831PS51861PS52061PS52201PS52231PS52531PS52801PS52831PS53111PS53131PS53151PS53161PS5317- Frame size 80 ... 315 80 ... 315 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND … 1 3 6 8 9 80 ... 315 80 ... 315 80 ... 112 80 ... 112 80 ... 315 80 ... 315 80 ... 315 0 1 2 3 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 30 2.780,– 3.280,– 3.810,– 4.220,– 4.840,– 5.730,– 6.890,– 8.580,– 10.300,– 11.500,– 12.600,– 15.600,– 18.300,– 20.600,– 23.900,– 30.600,– 34.600,– 41.200,– 46.500,– 54.900,– 65.600,– 79.800,– Order code - 0 1 80 ... 112 80 ... 315 80 ... 315 80 ... 315 80 ... 315 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 -4NA3 … Discount level A IIC DVGW…/1PS5… LOHER CHEMSTAR 0,22/1,1 80 B a.A. 0,5/2 90 L a.A. 0,65/2,4 100 L a.A. 0,8/3 100 L a.A. 1,1/4,1 112 M a.A. 1,6/6 132 S a.A. 2,2/9 132 M a.A. 3/12 160 M a.A. 4/16 160 L a.A. 5,5/20 180 M a.A. 6,3/25 180 L a.A. 8,5/33 200 L a.A. 10,5/38 225 S a.A. 13/46 225 M a.A. 15/55 250 M a.A. 20/75 280 S a.A. 24/90 280 M a.A. 27/110 315 S a.A. 33/132 315 M a.A. 37/145 315 M a.A. 44/172 315 L a.A. 50/200 315 L a.A. LOHER VARIO on request Options acc. surcharge price list 1PS4… / 1PS5… 4-/2-pole: 1500/3000 rpm at 50Hz with 1 winding in Dahlander connection for fan drive LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Pole-changing motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Mains-fed operation: double pole-changing for square-law load torque · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame size Prated 60Hz kW FS kW Article No. Motor type Price for 1 unit for IM B3 Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 230 V, 50 Hz 500 V, 50 Hz 400 V, 50 Hz 690 V, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 For other types of construction see options list 1) Rated output, partial utilization up to 155°C (F). 1) DVGW-080BS-84 DVGW-090LS-84 DVGW-100LR-84 DVGW-100LS-84 DVGW-112MS-84 DVGW-132SR-84 DVGW-132MR-84 DVGW-160MR-84 DVGW-160LS-84 DVGW-180MR-84 DVGW-180LS-84 DVGW-200LR-84 DVGW-225SR-84 1) DVGW-225MS-84 DVGW-250MM-84 DVGW-280SL-84 DVGW-280MM-84 DVGW-315SL-84 DVGW-315ML-84 DVGW-315MN-84 DVGW-315LL-84 DVGW-315LM-84 1PS50811PS50981PS51061PS51081PS51131PS51311PS51331PS51631PS51661PS51831PS51861PS52061PS52201PS52231PS52531PS52801PS52831PS53111PS53131PS53151PS53161PS5317- Frame size 80 ... 315 80 ... 315 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND … 1 3 6 8 9 80 ... 315 80 ... 315 80 ... 112 80 ... 112 80 ... 315 80 ... 315 80 ... 315 0 1 2 3 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 31 3.060,– 3.350,– 3.890,– 4.310,– 4.940,– 5.850,– 7.040,– 7.860,– 8.680,– 10.500,– 12.900,– 15.900,– 18.700,– 21.000,– 24.300,– 31.200,– 35.300,– 41.900,– 47.300,– 55.900,– 66.700,– 81.100,– Order code - 0 1 80 ... 112 80 ... 315 80 ... 315 80 ... 315 80 ... 315 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 -4QA3 … Discount level A IIC DVGW…/1PS5… LOHER CHEMSTAR 0,12/0,7 80 B a.A. 0,35/1,3 90 L a.A. 0,45/2 100 L a.A. 0,55/2,5 100 L a.A. 0,9/3,7 112 M a.A. 1,3/5 132 S a.A. 1,7/6,8 132 M a.A. 3/10 160 M a.A. 3,5/13 160 L a.A. 4/16 180 M a.A. 5/20 180 L a.A. 7/28 200 L a.A. 8/33 225 S a.A. 9,5/39 225 M a.A. 11/49 250 M a.A. 17/68 280 S a.A. 20/80 280 M a.A. 22/95 315 S a.A. 26/110 315 M a.A. 30/130 315 M a.A. 38/160 315 L a.A. 45/180 315 L a.A. LOHER VARIO on request Options acc. surcharge price list 1PS4… / 1PS5… 8-/4-pole: 750/1500 rpm at 50Hz with 1 winding in Dahlander connection for fan drive LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Pole-changing motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Mains-fed operation: double pole-changing for square-law load torque · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame size Prated 60Hz kW FS kW Motor type Article No. Price for 1 unit for IM B3 6-/4-pole: 1000/1500 rpm at 50Hz with 2 separate windings for fan drive Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 230 V, 50 Hz 500 V, 50 Hz 400 V, 50 Hz 690 V, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 For other types of construction see options list 1) Rated output, partial utilization up to 155°C (F). 1PS50981PS51061PS51081PS51131PS51311PS51331PS51631PS51651PS51661PS51831PS51861PS52061PS52081PS52201PS52231PS52531PS52801PS52831PS53111PS53131PS53151PS53161PS5317- Frame size 90 ... 315 90 ... 315 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND … 1 3 6 8 9 90 ... 315 90 ... 315 90 ... 112 90 ... 112 90 ... 315 90 ... 315 90 ... 315 0 1 2 3 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 32 3.420,– 3.970,– 4.400,– 5.050,– 5.970,– 7.190,– 8.070,– 8.950,– 10.800,– 12.000,– 13.300,– 14.700,– 16.200,– 19.100,– 21.500,– 24.900,– 31.900,– 36.100,– 42.900,– 48.400,– 57.200,– 68.300,– 83.100,– Order code - 0 1 90 ... 112 90 ... 315 90 ... 315 90 ... 315 90 ... 315 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 -4PA3 … Options acc. surcharge price list 1PS4… / 1PS5… DVGW-090LS-64 DVGW-100LR-64 DVGW-100LS-64 DVGW-112MS-64 DVGW-132SR-64 DVGW-132MR-64 DVGW-160MR-64 DVGW-160MS-64 DVGW-160LS-64 DVGW-180MR-64 DVGW-180LS-64 DVGW-200LR-64 DVGW-200LS-64 DVGW-225SR-64 DVGW-225MS-64 DVGW-250MM-64 DVGW-280SL-64 DVGW-280MM-64 DVGW-315SL-64 DVGW-315ML-64 DVGW-315MN-64 1) DVGW-315LL-64 1) DVGW-315LM-64 Discount level A IIC DVGW…/1PS5… LOHER CHEMSTAR 0,4/1,3 90 L a.A. 0,6/1,8 100 L a.A. 0,75/2,4 100 L a.A. 0,9/3 112 M a.A. 1,25/4,2 132 S a.A. 1,65/5,5 132 M a.A. 2,2/7,5 160 M a.A. 3/9 160 M a.A. 3,5/12 160 L a.A. 4,5/14 180 M a.A. 5,5/16,5 180 L a.A. 7/20 200 L a.A. 9/26 200 L a.A. 10/31 225 S a.A. 13/38 225 M a.A. 17/48 250 M a.A. 25/70 280 S a.A. 30/82 280 M a.A. 32/95 315 S a.A. 37/115 315 M a.A. 47/135 315 M a.A. 55/160 315 L a.A. 75/200 315 L a.A. LOHER VARIO on request LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Pole-changing motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Mains-fed operation: double pole-changing for square-law load torque · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame size Prated 60Hz kW FS kW Motor type Article No. Price for 1 unit for IM B3 Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 230 V, 50 Hz 500 V, 50 Hz 400 V, 50 Hz 690 V, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 For other types of construction see options list 1) Rated output, partial utilization up to 155°C (F). DVGW-090LS-86 DVGW-100LR-86 DVGW-100LS-86 DVGW-112MS-86 DVGW-132SR-86 DVGW-132MR-86 DVGW-160MR-86 DVGW-160LS-86 DVGW-180LS-86 DVGW-200LR-86 DVGW-225SR-86 DVGW-225MS-86 DVGW-250MM-86 DVGW-280SL-86 DVGW-280MM-86 DVGW-315SL-86 DVGW-315ML-86 DVGW-315MN-86 DVGW-315LL-86 1) DVGW-315LM-86 1PS50981PS51061PS51081PS51131PS51311PS51331PS51631PS51661PS51861PS52061PS52201PS52231PS52531PS52801PS52831PS53111PS53131PS53151PS53161PS5317- Frame size 90 ... 315 90 ... 315 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND … 1 3 6 8 9 90 ... 315 90 ... 315 90 ... 112 90 ... 112 90 ... 315 90 ... 315 90 ... 315 0 1 2 3 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 33 3.470,– 4.020,– 4.450,– 5.110,– 6.050,– 7.270,– 9.050,– 10.900,– 13.400,– 16.500,– 19.400,– 21.900,– 25.300,– 32.500,– 36.700,– 43.600,– 49.200,– 58.200,– 69.400,– 84.500,– Order code - 0 1 90 ... 112 90 ... 315 90 ... 315 90 ... 315 90 ... 315 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 -4RA3 … Discount level A IIC DVGW…/1PS5… LOHER CHEMSTAR 0,32/0,75 90 L a.A. 0,45/1 100 L a.A. 0,55/1,3 100 L a.A. 0,8/1,9 112 M a.A. 1,1/2,6 132 S a.A. 1,6/3,8 132 M a.A. 2,5/6 160 M a.A. 3,5/8 160 L a.A. 5,5/12,5 180 L a.A. 9,5/20 200 L a.A. 11/24 225 S a.A. 13/28 225 M a.A. 16/34 250 M a.A. 25/50 280 S a.A. 30/60 280 M a.A. 33/70 315 S a.A. 40/85 315 M a.A. 47/100 315 M a.A. 55/120 315 L a.A. 70/150 315 L a.A. LOHER VARIO on request Options acc. surcharge price list 1PS4… / 1PS5… 8-/6-pole: 750/1000 rpm at 50Hz with 2 separate windings for fan drive LOHER CHEMSTAR 1PS5 motor series Brake motors with High Efficiency IE2 in cast-iron versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE2, 0,75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame Prated 60Hz size kW FS IE class Motor type Article No. Price for 1 unit for IM B3 kW 4-pole: 1500 rpm at 50Hz DBGW-080BS-04 DBGW-090LR-04 DBGW-090LS-04 DBGW-100LR-04 DBGW-100LS-04 DBGW-112MS-04 DBGW-132SR-04 DBGW-132MS-04 DBGW-160MR-04 DBGW-160LS-04 DBGW-180MR-04 DBGW-180LS-04 DBGW-200LS-04 1PS50811PS50951PS50981PS51061PS51081PS51131PS51311PS51331PS51631PS51661PS51831PS51861PS5206- RD RD RD RD RD RD RD RD RD RD RD RD RD -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 -4BA3 6.880,– 7.060,– 7.450,– 7.840,– 8.730,– 9.200,– 9.870,– 11.300,– 12.600,– 14.200,– 15.100,– 16.900,– 19.200,– IIC DBGW…/1PS5… 1) IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 IE2 DBGW-080BS-06 DBGW-090LR-06 DBGW-090LS-06 DBGW-100LS-06 DBGW-112MS-06 DBGW-132SR-06 DBGW-132MR-06 DBGW-132MS-06 DBGW-160MR-06 DBGW-160LS-06 DBGW-180LS-06 DBGW-200LR-06 DBGW-200LS-06 1PS50811PS50951PS50981PS51061PS51131PS51311PS51331PS51351PS51631PS51661PS51861PS52061PS5208- Operating modes Frame size Mains-fed operation 80 ... 200 Converter-fed operation, standard insulation 80 ... 200 Converter-fed operation with special insulation 160 ... 200 (derating approx. 5 %) Voltages 230 V/400 V, 50 Hz 80 ... 112 500 VY, 50 Hz 80 ... 200 400 V/690 V, 50 Hz Standard 690 VY, 50 Hz 80 ... 200 For other voltages see options list 71 ... 500 Types of construction IM B3 Standard IM B5 80 ... 200 IM B34 80 ... 200 IM B14 80 ... 200 IM V1/canopy 80 ... 200 IM B35 80 ... 200 For other types of construction see options list 80 ... 200 1) Outside the IE code classification according to IEC60034-30. RD RD RD RD RD RD RD RD RD RD RD RD RD … 1 3 6 8 9 0 1 2 3 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 34 6.990,– 7.180,– 7.570,– 7.990,– 9.490,– 10.200,– 11.100,– 12.400,– 13.000,– 14.600,– 17.400,– 18.600,– 19.700,– Order code - 0 1 2 Standard brake supply: 230 V, 1-phase AC -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 -4CA3 … Options acc. surcharge price list 1PS4… / 1PS5… LOHER CHEMSTAR 0,55 80 B a.A. 0,75 90 L a.A. 1,1 90 L a.A. 1,5 100 L a.A. 2,2 112 M a.A. 3,0 132 S a.A. 4,0 132 M a.A. 5,5 132 M a.A. 7,5 160 M a.A. 11 160 L a.A. 15 180 L a.A. 18,5 200 L a.A. 22 200 L a.A. IIC DBGW…/1PS5… Discount level A LOHER CHEMSTAR 0,75 80 B a.A. IE2 1,1 90 L a.A. IE2 1,5 90 L a.A. IE2 2,2 100 L a.A. IE2 3,0 100 L a.A. IE2 4,0 112 M a.A. IE2 5,5 132 S a.A. IE2 7,5 132 M a.A. IE2 11 160 M a.A. IE2 15 160 L a.A. IE2 18,5 180 M a.A. IE2 22 180 L a.A. IE2 30 200 L a.A. IE2 6-pole: 1000 rpm at 50Hz LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Motors in cast-iron and steel versions · Cooling: water-cooled (IC71W) · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb kW FS kW 2-pole: 3000 rpm at 50Hz LOHER CHEMSTAR 2) 55 200 D a.A. 2) 75 200 E a.A. 2) 90 200 E a.A. 2) 90 225 E a.A. 2) 120 225 F a.A. 2) 120 250 E a.A. 2) 132 250 E a.A. 2) 185 250 F a.A. 2) 220 250 G a.A. 2) 250 280 G a.A. 2) 280 280 J a.A. 2) 315 280 J a.A. 2) 355 280 J a.A. 3) 400 315 J a.A. 3) 500 315 J a.A. LOHER VARIO on request 4-pole: 1500 rpm at 50Hz LOHER CHEMSTAR 2) 55 200 E a.A. 2) 75 200 F a.A. 2) 90 200 F a.A. 2) 90 225 F a.A. 2) 120 225 G a.A. 2) 120 250 E a.A. 2) 132 250 F a.A. 2) 185 250 F a.A. 2) 220 250 G a.A. 2) 250 280 G a.A. 2) 280 280 J a.A. 2) 315 280 J a.A. 2) 355 280 J a.A. 3) 400 315 J a.A. 3) 500 315 P a.A. LOHER VARIO on request Operating modes Mains-fed operation Converter-fed operation, standard insulation Converter-fed operation with special insulation (derating approx. 5 %) Voltages 500 VY, 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM V1/canopy IM B35 For other types of construction see options list 1) Motor with special rotor (Cu). Motor type Article No. DNWW-200DG-02 DNWW-200EF-02 1) DNWW-200EF-02 DNWW-225EF-02 1) DNWW-225FF-02 DNWW-250EA-02 DNWW-250EF-02 1) DNWW-250FF-02 1) DNWW-250GF-02 DNWW-280GA-02 1) 1) DNWW-280JA-02 DNWW-280JA-02 1) 1) DNWW-280JA-02 DNWW-315JE-02 1) DNWW-315JE-02 1) 1PS52021PS52031PS52041PS52231PS52241PS52521PS52531PS52541PS52551PS52841PS52851PS52861PS52871PS53161PS5317- DNWW-200EA-04 DNWW-200FA-04 DNWW-200FA-04 1) DNWW-225FA-04 DNWW-225GF-04 1) DNWW-250EA-04 DNWW-250FA-04 DNWW-250FF-04 1) DNWW-250GF-04 1) DNWW-280GF-04 1) DNWW-280JG-04 1) DNWW-280JG-04 1) DNWW-280JG-04 1) 1) DNWW-315JE-04 DNWW-315PA-04 1) 1PS52021PS52031PS52041PS52231PS52251PS52521PS52531PS52541PS52551PS52851PS52861PS52871PS52881PS53161PS5317- Frame size 200 ... 315 200 ... 315 200 ... 315 Not according to EG 640/2009. Outside the IE code classification according to IEC60034-30. BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX 35 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. -4BA0 -4BA0 -4BB0 -4BA0 -4BB0 -4BA0 -4BA0 -4BB0 -4BB0 -4BB0 -4BB0 -4BB0 -4BB0 -4BB0 -4BB0 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. … 0 1 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. -4AA0 -4AA0 -4AB0 -4AA0 -4AB0 -4AA0 -4AA0 -4AB0 -4AB0 -4AB0 -4AB0 -4AB0 -4AB0 -4AB0 -4AB0 Order code - 3 6 8 9 200 ... 315 200 ... 315 200 ... 315 200 ... 315 200 ... 315 3) 0 1 2 200 ... 315 200 ... 315 200 ... 315 200 ... 315 2) Price for 1 unit for IM B3 … Discount level A Prated 60Hz Options acc. surcharge price list 1PS4… / 1PS5… Frame size Discount level A Prated 50Hz LOHER CHEMSTAR 1PS5 motor series IE3 Motors in cast-iron versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE3, 0,75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame Prated 60Hz size kW FS IE class Motor type Article No. DNGW-080BS-02 1) 1) DNGW-080BT-02 DNGW-090LS-02 DNGW-090LT-02 DNGW-100LT-02 DNGW-112MT-02 DNGW-132SS-02 DNGW-132ST-02 DNGW-160MS-02 DNGW-160MT-02 DNGW-160LT-02 DNGW-180MT-02 DNGW-200LS-02 DNGW-200LT-02 DNGW-225MT-02 DNGW-250MN-02 DNGW-280SM-02 DNGW-280MN-02 DNGW-315SL-02 DNGW-315ML-02 DNGW-315MN-02 DNGW-315LL-02 DNGW-315LN-02 1PS50801PS50811PS50951PS50981PS51061PS51131PS51311PS51321PS51631PS51651PS51661PS51831PS52061PS52081PS52231PS52531PS52801PS52831PS53111PS53131PS53151PS53161PS5318- Price for 1 unit for IM B3 Operating modes Frame size Mains-fed operation 80 ... 315 Converter-fed operation, standard insulation 80 ... 315 Voltages 690 VD , 50Hz 80 ... 315 230 V/400 V, 50 Hz 80 ... 280 500 VY, 50 Hz 80 ... 315 500 VD , 50 Hz 80 ... 315 400 V/690 V, 50 Hz 80 ... 315 690 VY, 50 Hz 80 ... 315 For other voltages see options list 80 ... 315 Types of construction IM B3 80 ... 315 IM B5 80 ... 315 IM B34 80 ... 112 IM B14 80 ... 112 80 ... 315 IM V1/canopy IM B35 80 ... 315 For other types of construction see options list 80 ... 315 1) Optionally available in Ex nA, Loher type changing to ANGK… BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD … 0 1 3 5 6 8 9 0 1 2 3 4 6 9 36 2.270,– 2.450,– 2.660,– 3.060,– 3.450,– 3.970,– 4.750,– 5.660,– 7.180,– 8.570,– 9.500,– 10.600,– 13.100,– 15.300,– 17.400,– 20.300,– 26.300,– 29.900,– 35.700,– 40.600,– 48.300,– 58.000,– 71.300,– Order code - 0 1 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 -4AH3 … Options acc. surcharge price list 1PS5… Discount level A kW 2-pole: 3000 rpm at 50Hz LOHER CHEMSTAR 0,75 80 B 0,75 IE3 1,1 80 B 1,1 IE3 1,5 90 L 1,5 IE3 2,2 90 L 2,2 IE3 3 100 L 3 IE3 4 112 M 4 IE3 5,5 132 S 5,5 IE3 7,5 132 S 7,5 IE3 11 160 M 11 IE3 15 160 M 15 IE3 18,5 160 L 18,5 IE3 22 180 M 22 IE3 30 200 L 30 IE3 37 200 L 37 IE3 45 225 M 45 IE3 55 250 M 55 IE3 75 280 S 75 IE3 90 280 M 90 IE3 110 315 S 110 IE3 132 315 M 132 IE3 160 315 M 160 IE3 200 315 L 200 IE3 250 315 L 250 IE3 LOHER CHEMSTAR 1PS5 motor series IE3 Motors in cast-iron versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE3, 0,75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame Prated 60Hz size kW FS IE class Motor type Article No. DNGW-080BT-04 1) DNGW-090LS-04 DNGW-090LT-04 DNGW-100LS-04 DNGW-100LT-04 DNGW-112MT-04 DNGW-132ST-04 DNGW-132MT-04 DNGW-160MS-04 DNGW-160LT-04 DNGW-180MS-04 DNGW-180LT-04 DNGW-200LT-04 DNGW-225SS-04 DNGW-225MT-04 DNGW-250MN-04 DNGW-280SM-04 DNGW-280MN-04 DNGW-315SL-04 DNGW-315ML-04 DNGW-315MN-04 DNGW-315LL-04 DNGW-315LM-04 1PS50811PS50951PS50981PS51061PS51081PS51131PS51311PS51331PS51631PS51661PS51831PS51861PS52061PS52201PS52231PS52531PS52801PS52831PS53111PS53131PS53151PS53161PS5317- Price for 1 unit for IM B3 Operating modes Frame size Mains-fed operation 80 ... 315 Converter-fed operation, standard insulation 80 ... 315 Voltages 690 VD , 50Hz 80 ... 315 230 V/400 V, 50 Hz 80 ... 280 500 VY, 50 Hz 80 ... 315 500 VD , 50 Hz 80 ... 315 400 V/690 V, 50 Hz 80 ... 315 690 VY, 50 Hz 80 ... 315 For other voltages see options list 80 ... 315 Types of construction IM B3 80 ... 315 IM B5 80 ... 315 IM B34 80 ... 112 IM B14 80 ... 112 80 ... 315 IM V1/canopy IM B35 80 ... 315 For other types of construction see options list 80 ... 315 1) Optionally available in Ex nA, Loher type changing to ANGK… BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD … 0 1 3 5 6 8 9 0 1 2 3 4 6 9 37 2.210,– 2.410,– 2.590,– 3.040,– 3.350,– 3.860,– 4.620,– 5.500,– 6.980,– 8.330,– 9.340,– 10.300,– 12.700,– 15.000,– 16.900,– 19.700,– 25.400,– 28.800,– 34.400,– 39.000,– 46.300,– 55.500,– 67.900,– Order code - 0 1 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 … Options acc. surcharge price list 1PS5… Discount level A kW 4-pole: 1500 rpm at 50Hz LOHER CHEMSTAR 0,75 80 B 0,75 IE3 1,1 90 L 1,1 IE3 1,5 90 L 1,5 IE3 2,2 100 L 2,2 IE3 3 100 L 3 IE3 4 112 M 4 IE3 5,5 132 S 5,5 IE3 7,5 132 M 7,5 IE3 11 160 M 11 IE3 15 160 L 15 IE3 18,5 180 M 18,5 IE3 22 180 L 22 IE3 30 200 L 30 IE3 37 225 S 37 IE3 45 225 M 45 IE3 55 250 M 55 IE3 75 280 S 75 IE3 90 280 M 90 IE3 110 315 S 110 IE3 132 315 M 132 IE3 160 315 M 160 IE3 200 315 L 200 IE3 250 315 L 250 IE3 LOHER CHEMSTAR 1PS5 motor series IE3 Motors in cast-iron versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE3, 0,75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 60Hz kW FS kW IE class 6-pole: 1000 rpm at 50Hz LOHER CHEMSTAR 0,75 90 L 0,75 IE3 1,1 100 L 1,1 IE3 1,5 100 L 1,5 IE3 2,2 112 M 2,2 IE3 3 132 S 3 IE3 4 132 M 4 IE3 5,5 132 M 5,5 IE3 7,5 160 M 7,5 IE3 11 160 L 11 IE3 15 180 L 15 IE3 18,5 200 L 18,5 IE3 22 200 L 22 IE3 30 225 M 30 IE3 37 250 M 37 IE3 45 280 S 45 IE3 55 280 M 55 IE3 75 315 S 75 IE3 90 315 M 90 IE3 110 315 M 110 IE3 132 315 L 132 IE3 160 315 L 160 IE3 200 315 L 200 IE3 Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 690 VD , 50Hz 230 V/400 V, 50 Hz 500 VY, 50 Hz 500 VD , 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 For other types of construction see options list Motor type Article No. DNGW-090LS-06 DNGW-100LS-06 DNGW-100LT-06 DNGW-112MT-06 DNGW-132SS-06 DNGW-132MS-06 DNGW-132MT-06 DNGW-160MS-06 DNGW-160LT-06 DNGW-180LT-06 DNGW-200LS-06 DNGW-200LT-06 DNGW-225MT-06 DNGW-250MN-06 DNGW-280SM-06 DNGW-280MN-06 DNGW-315SL-06 DNGW-315ML-06 DNGW-315MM-06 DNGW-315LK-06 DNGW-315LL-06 DNGW-315LM-06 1PS50951PS51051PS51061PS51131PS51311PS51331PS51351PS51631PS51661PS51861PS52061PS52081PS52231PS52531PS52801PS52831PS53111PS53131PS53141PS53151PS53161PS5317- Frame size 90 ... 315 90 ... 315 Price for 1 unit for IM B3 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD … 0 1 3 5 6 8 9 90 ... 315 90 ... 315 90 ... 112 90 ... 112 90 ... 315 90 ... 315 90 ... 315 0 1 2 3 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 38 2.530,– 2.900,– 3.190,– 4.150,– 4.980,– 5.900,– 6.530,– 7.360,– 8.740,– 10.800,– 12.100,– 13.200,– 17.600,– 20.500,– 26.300,– 29.800,– 35.500,– 40.300,– 44.000,– 47.700,– 57.100,– 69.900,– Order code - 0 1 90 ... 315 90 ... 280 90 ... 315 90 ... 315 90 ... 315 90 ... 315 90 ... 315 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 … Options acc. surcharge price list 1PS5… Frame size Discount level A Prated 50Hz LOHER CHEMSTAR 1PS5 motor series IE3 Brake motors with High Efficiency IE3 in cast-iron versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE3, 0,75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Explosion-proof enclosure" according to EN 60079-1; 2007: CE 0102 II 2G Ex d(e) IIC T4 Gb Prated 50Hz Frame Prated 60Hz size kW FS IE class Motor type Article No. DBGW-080BT-04 DBGW-090LS-04 DBGW-090LT-04 DBGW-100LS-04 DBGW-100LT-04 DBGW-112MT-04 DBGW-132ST-04 DBGW-132MT-04 DBGW-160MS-04 DBGW-160LT-04 DBGW-180MS-04 DBGW-180LT-04 DBGW-200LT-04 1PS50811PS50951PS50981PS51061PS51081PS51131PS51311PS51331PS51631PS51661PS51831PS51861PS5206- DBGW-090LS-06 DBGW-100LS-06 DBGW-100LT-06 DBGW-112MT-06 DBGW-132SS-06 DBGW-132MS-06 DBGW-132MT-06 DBGW-160MS-06 DBGW-160LT-06 DBGW-180LT-06 DBGW-200LS-06 DBGW-200LT-06 1PS50951PS51051PS51061PS51131PS51311PS51331PS51351PS51631PS51661PS51861PS52061PS5208- Price for 1 unit for IM B3 Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 230 V/400 V, 50 Hz 500 VY, 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 For other types of construction see options list Frame size 80 ... 200 80 ... 200 RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD 0 1 2 3 4 6 9 Standard brake supply: 230 V, 1-phase AC Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 39 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 -4CH3 7.490,– 8.070,– 8.360,– 9.900,– 10.700,– 11.600,– 12.900,– 13.700,– 15.300,– 18.200,– 19.500,– 20.600,– … 1 3 6 8 9 Standard 80 ... 200 80 ... 112 80 ... 112 80 ... 200 80 ... 200 80 ... 200 7.170,– 7.370,– 7.760,– 8.210,– 9.100,– 9.610,– 10.400,– 11.800,– 13.300,– 14.900,– 15.900,– 17.700,– 20.100,– Order code - 0 1 80 ... 200 80 ... 200 Standard 80 ... 200 80 ... 200 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 -4BH3 … Options acc. surcharge price list 1PS5… Discount level A kW 4-pole: 1500 rpm at 50Hz LOHER CHEMSTAR 0,75 80 B 0,75 IE3 1,1 90 L 1,1 IE3 1,5 90 L 1,5 IE3 2,2 100 L 2,2 IE3 3,0 100 L 3,0 IE3 4,0 112 M 4,0 IE3 5,5 132 S 5,5 IE3 7,5 132 M 7,5 IE3 11 160 M 11 IE3 15 160 L 15 IE3 18,5 180 M 18,5 IE3 22 180 L 22 IE3 30 200 L 30 IE3 6-pole: 1000 rpm at 50Hz LOHER CHEMSTAR 0,75 90 L 0,75 IE3 1,1 100 L 1,1 IE3 1,5 100 L 1,5 IE3 2,2 112 M 2,2 IE3 3,0 132 S 3,0 IE3 4,0 132 M 4,0 IE3 5,5 132 M 5,5 IE3 7,5 160 M 7,5 IE3 11 160 L 11 IE3 15 180 L 15 IE3 18,5 200 L 18,5 IE3 22 200 L 22 IE3 LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Article No. supplements Selection and ordering data Voltages 1PS4. . . - . . . 1PS5. . . - . . . Voltage Additional Motor series code identification LOHER CHEMSTAR 11th position code with Surcharge / List price EURO of the order code Article No. and plain text .-.... .-.... if required LOHER VARIO Discount level A Discount level C Frame size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Optional voltages 690 V D, 50Hz 0 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 230 V D / 400 V S, 50Hz 1 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N N N 500 V S, 50Hz 3 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N N 400 V D, 50Hz 4 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 500 V D, 50Hz 5 65,– 74,– 87,– 107,– 130,– o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 400 V D / 690 V S, 50Hz 6 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 690 V S, 50Hz 8 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N 415 V S, 50Hz 1) 9 L1C 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– N N N N N o.MP. 415 V D, 50Hz 1) 9 L1D 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– o.MP. o.MP. o.MP. 380 V D / 660 V S, 50Hz 1) 9 L1L 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 220 V D / 380 V S, 50Hz 1) 9 L1R 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– N N N N N N 9 9 L1V L1Y ● and identification code 65,– 65,– 74,– 74,– 87,– 87,– 107,– 107,– 130,– 130,– 165,– 165,– 206,– 206,– 265,– 265,– 323,– 323,– 478,– 478,– 603,– 603,– 772,– 772,– 1.000,– 1.000,– N 1.210,– N a.A. N a.A. N a.A. N a.A. 1000 V D, 50 Hz 1) Other voltages 1) 220 V D / 380 V S, 60Hz (50Hz-output) 1) 9 L2A 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– N N N N N N 220 V D / 380 V S, 60Hz (60Hz-output) 1) 9 L2B 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– N N N N N N 380 V D / 660 V S, 60Hz (50Hz-output) 1) 9 L2C 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– N N N N N N 380 V D / 660 V S, 60Hz (60Hz-output) 1) 9 L2D 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– N N N N N N N N N N N 460 V S, 60Hz (60Hz-output) 1) 9 L2E 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– N 460 V D, 60Hz (60Hz-output) 1) 9 L2F 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– N 575 V S, 60Hz (60Hz-output) 1) 9 L2L 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– N 575 V D, 60Hz (60Hz-output) 1) 9 L2M 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– N see PMD N N see PMD 440 V S, 60Hz (50Hz-output) 1) 9 L2Q 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– N N N N N 440 V D, 60Hz (50Hz-output) 1) 9 L2R 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– N N N N N 460 V S, 60Hz (50Hz-output) 1) 9 L2S 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– N N N N N 460 V D, 60Hz (50Hz-output) 1) 9 L2T 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– N N N N N 575 V S, 60Hz (50Hz-output) 1) 9 L2U 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– N N N N N 575 V D, 60Hz (50Hz-output) 1) 9 L2V 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– N N N N N N N N N see PMD a.A. a.A. a.A. 440 V S, 60Hz (60Hz-output) 1) 9 L2W 33,– 37,– 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– N 440 V D, 60Hz (60Hz-output) 1) 9 9 L2X L2Y ● and identification code 33,– N 37,– N 43,– N 54,– N 65,– N 83,– N 102,– N 132,– N 152,– N 213,– N 243,– N 314,– N 408,– N N N Other voltages 60Hz 1) 1) = Basis 1 - 4 pcs. / calculate factor 0.5 for 5 - 19 pcs. ! □ = Standard version o.MP. = Without surcharge For dual voltages 230 V/400 V, 220 V/380 V, 400 V/690 V or 380 V/660 V: ● = This order code only determines the price of the version - additional plain text is required. - For motors with a Dahlander circuit, the lower voltage is generally specified. a.A. = On request Voltages not listed are only available on request. - For motors for converter-fed operation, the converter rating plate is stamped with 380 V or 400 V. N = Not available Standard brake supply voltage: 230 V, 1-phase AC Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. A 40 a.A. LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Article No. supplements Selection and ordering data Types of construction 1PS4. . . - . . . . 1PS5. . . - . . . . Mounting Additional Motor series type code identification LOHER CHEMSTAR 12th position code with Surcharge / List price EURO of the order code Article No. and plain text -.... -.... if required LOHER VARIO Discount level A Discount level C Frame size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Optional types of construction IM B3 0 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. IM B5 2) 1 73,– 82,– 95,– 117,– 146,– 199,– 266,– 431,– 508,– 637,– 809,– 1.010,– 1.330,– N N N N N IM B34 2 91,– 95,– 118,– 146,– 189,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N N IM B14 3 73,– 82,– 95,– 117,– 146,– a.A. a.A. a.A. N N N N N N N N N N IM V1, with canopy - LOHER CHEMSTAR 4 127,– 150,– 168,– 199,– 243,– 321,– 433,– 699,– 856,– 1.070,– 1.340,– 1.650,– 2.190,– 3.160,– N N N N IM V1, with canopy - LOHER VARIO 50Hz 2-pole (11: 0,4,5,6; 14: A) 4 5.110,– 6.860,– 11.300,– a.A. IM V1, with canopy - LOHER VARIO 60Hz 2-pole (11: 9; 14: A) 4 6.810,– 9.150,– a.A. a.A. 11.400,– IM V1, with canopy - LOHER VARIO 4-pole (14: B) 4 3.410,– 4.580,– 5.630,– IM V1, with canopy - LOHER VARIO ab 6-pole (14: C,D,E,F,G,H) 4 3.410,– 4.580,– 5.630,– 7.580,– IM B35 6 IM B6 2) 9 IM B7 2) 9 IM B8 2) 91,– 95,– 118,– 146,– 189,– 305,– 467,– 546,– 637,– 809,– 1.090,– 1.410,– 1.860,– 2.980,– 3.410,– 4.580,– 5.630,– 7.580,– M1A o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. a.A. a.A. N N N N M1B o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. a.A. a.A. N N N N 9 M1C o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. a.A. a.A. N N N N IM V6 2) 9 M1E o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. a.A. a.A. N N N N IM V5, with canopy 2) 9 M1F 57,– 68,– 80,– 84,– 102,– 131,– 171,– 275,– 362,– 454,– 568,– 683,– 909,– 1.410,– N N N N IM V3 9 M1G 73,– 82,– 94,– 117,– 146,– 199,– 266,– 431,– 508,– 637,– 809,– 1.010,– 1.330,– a.A. N N N N IM V15, with canopy 9 M2K 145,– 163,– 191,– 228,– 286,– 427,– 634,– 814,– 985,– 1.240,– 1.620,– 2.050,– 2.720,– a.A. N N N N IM V18, with canopy 9 M2M 127,– 150,– 168,– 199,– 243,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N N Other types of construction and special flange diameters on request ! 2) LOHER CHEMSTAR at frame size 315 / 355 only for direct coupling without vibrations, others on request □ = Standard version o.MP. = Without surcharge ● = This order code only determines the price of the version - additional plain text is required. a.A. = On request N = Not available Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. A 41 LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code 1PS4. . . - . . . . . - . . . . -Z and plain text 1PS5. . . - . . . . . - . . . . -Z if required Discount level C Frame size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Special electrical designs / winding protection Design with reduced starting current - factory clarification required and eventually type test needed, a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. ETO-Option (Engineer To Order) without order code Special design according load curve of driven equipment or customer requirements - factory clarification required and eventually type test needed, ETO-Option without order code Adjusting of rating according to customer requirements - factory clarification required and eventually type test needed, a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. Motor protection with 3 PTC thermistors for switching-off - without lightning arresters, sole protection not included A11 249,– 249,– 249,– 249,– 249,– 249,– 249,– 349,– 349,– 349,– 349,– 349,– 349,– 439,– 1.150,– 1.150,– 1.150,– 2.300,– Motor protection with 2 x 3 PTC thermistors for prewarning / switching-off - without lightning arresters, 571,– 1.730,– 1.730,– 1.730,– 3.460,– 2.500,– 2.500,– 3.000,– 4.000,– ETO-Option without order code A12 423,– 423,– 423,– 423,– 423,– 423,– 423,– 512,– 512,– 512,– 512,– 512,– 512,– Motor protection with 3 PTC thermistors for switching-off as sole protection with inverter (TMS) A15 449,– 449,– 449,– 449,– 449,– 449,– 449,– 593,– 593,– 593,– 727,– 727,– 727,– 817,– Motor protection with 2 x 3 PTC thermistors for prewarning/switching-off as sole protection with inverter (TMS) A16 763,– 763,– 763,– 763,– 763,– 763,– 763,– 870,– 870,– 870,– 870,– 870,– 870,– 1.060,– 3.000,– 3.000,– 3.500,– 4.750,– Temperature measuring of the winding by means of embedded temperature sensor KTY84-130 A23 449,– 449,– 449,– 449,– 449,– 449,– 449,– 593,– 593,– 593,– 727,– 727,– 727,– 817,– 1.150,– 1.150,– 1.150,– 1.150,– A25 763,– 763,– 763,– 763,– 763,– 1.750,– 1.750,– 1.750,– 1.750,– sole protection not included Temperature measuring of the winding by means of embedded temperature sensors 2 x KTY84-130 763,– 763,– 870,– 870,– 870,– 870,– 870,– 870,– 1.060,– Temperature monitoring of winding with 3 resistance thermometer PT100 - in 2-wire design A60 N N N N N N 1.620,– 1.620,– 1.620,– 1.620,– 1.620,– 1.620,– 1.620,– 1.620,– N N N N Temperature monitoring of winding with 2 x 3 resistance thermometer PT100 - 2-wire design, A61 N N N N N N a.A. a.A. a.A. a.A. a.A. 2.100,– 2.100,– 2.100,– 1.730,– 1.730,– 1.730,– 1.730,– round wire winding only 3 PT100 resistance thermometers in stator winding, 3-wire circuit from terminals of the auxiliary terminal box N N 6 PT100 resistance thermometers in stator winding, 3-wire circuit from terminals of the auxiliary terminal box A64 N N N N N N N N N N N N N 3.000,– 2.000,– 2.000,– 2.000,– 2.000,– 6 embedded resistance thermometers PT100 without lightning arresters for 4-wire connection from terminals A65 A63 N N N N N N N N N N N N N N N N N N N N N N N N N N 1.730,– 1.150,– 1.730,– 1.150,– 1.730,– 1.150,– 1.730,– 1.150,– A66 N N N N N N N N N N N N N N 3.450,– 3.450,– 3.450,– 3.450,– - only at form coil winding 6 embedded resistance thermometers PT100 with lightning arresters for 4-wire connection from terminals - only at form coil winding 6 embedded resistance thermometers PT100 in shielded design without lightning arresters for 4-wire connection A67 N N N N N N N N N N N N N N 3.450,– 3.450,– 3.450,– 3.450,– Q40 N N N N N N N N N N N N N N 4.320,– 4.320,– 4.320,– 4.320,– from terminals - only at form coil winding 6 Exi-slot resistance thermometers PT100 in shielded design with lightning arrestors for 3- and 4-wire connection from terminal - only at form coil winding 2 double RTD's PT100 in shielded design (Ex i) for antifriction or sleeve bearing - 2-wire elements V80 N N N N N N N N N N N N N N 3.450,– 3.450,– 3.450,– 3.450,– Q43 N N N N N N N N N N N N N N 850,– 850,– 850,– 850,– with 4-wire connection ex terminal box Winding RTD's-PT100 in 3- or 4-wire type ex sensor instead ex terminal (not possible for Exi!) - optionally possible for A60, A61, A65, A66 Bearing RTD's-PT100 in 3- or 4-wire type ex sensor instead of ex terminal - optionally possible for V80, A40, A42 Q44 N N N N N N N N N N N N N N 576,– 576,– 576,– 576,– One thermocouple per bearing Q49 N N N N N N N N N N N N N N 4.320,– 4.320,– 4.320,– 4.320,– Sensor for enclosure vibration monitoring (preferred product) with loose cable - per sensor V14 N N N N N N N N N N N N N N 1.700,– 1.700,– 1.700,– 1.700,– Sensor for enclosure vibration monitoring (preferred product), without junction box - per sensor V15 N N N N N N N N N N N N N N 2.880,– 2.880,– 2.880,– 2.880,– 3 Transmitter 4-20 mA for PT100 winding P20 N N N N N N N N N N N N N N 2.500,– 2.500,– 2.500,– 2.500,– One Transmitter with digital display with Exd or Exi-approval V88 N 3.450,– 3.450,– 3.450,– 3.450,– PT100 winding in tolerance class A with calibration certificate V78 N N N N N N N N N N N N N N 2.850,– 2.850,– 2.850,– 2.850,– Site altitude max. 1500 m above sea level (observe derating) 2) D06 43,– 64,– 86,– 107,– 129,– 150,– 172,– 193,– 214,– 236,– 257,– 279,– 300,– 320,– 2.870,– 3.850,– 4.740,– 6.370,– Site altitude max. 2000 m above sea level (observe derating)2) D07 62,– 93,– 124,– 156,– 187,– 218,– 249,– 280,– 311,– 342,– 373,– 404,– 435,– 464,– 2.870,– 3.850,– 4.740,– 6.370,– 2) Site altitude max. 2500 m above sea level (observe derating) N N N N N N N N N N N N N D08 90,– 135,– 180,– 225,– 271,– 316,– 361,– 406,– 451,– 496,– 541,– 586,– 631,– 673,– 2.870,– 3.850,– 4.740,– 6.370,– Site altitude max. 3000 m above sea level (observe derating)2) D09 154,– 230,– 307,– 383,– 460,– 536,– 613,– 690,– 766,– 843,– 919,– 996,– 1.070,– 1.140,– 2.870,– 3.850,– 4.740,– 6.370,– Cooling air temperature max. 45 °C (observe derating) 2) D11 43,– 64,– 86,– 107,– 129,– 150,– 172,– 193,– 214,– 236,– 257,– 279,– 300,– 320,– 2.870,– 3.850,– 4.740,– 6.370,– Cooling air temperature max. 50 °C (observe derating) 2) D12 62,– 93,– 124,– 156,– 187,– 218,– 249,– 280,– 311,– 342,– 373,– 404,– 435,– 464,– 2.870,– 3.850,– 4.740,– 6.370,– Cooling air temperature max. 55 °C (observe derating) 2) D13 90,– 135,– 180,– 225,– 271,– 316,– 361,– 406,– 451,– 496,– 541,– 586,– 631,– 673,– 2.870,– 3.850,– 4.740,– 6.370,– Cooling air temperature max. 60 °C (observe derating) 2) D14 154,– 230,– 307,– 383,– 460,– 536,– 613,– 690,– 766,– 843,– 919,– 996,– 1.070,– 1.140,– 2.870,– 3.850,– 4.740,– 6.370,– D15 43,– 64,– 86,– 107,– 129,– 150,– 172,– 193,– 214,– 236,– 257,– 279,– 300,– N a.A. a.A. a.A. a.A. D16 62,– 93,– 124,– 156,– 187,– 218,– 249,– 280,– 311,– 342,– 373,– 404,– 435,– N a.A. a.A. a.A. a.A. D17 90,– 135,– 180,– 225,– 271,– 316,– 361,– 406,– 451,– 496,– 541,– 586,– 631,– N a.A. a.A. a.A. a.A. D18 65,– 74,– 87,– 107,– 130,– 165,– 206,– 265,– 323,– 478,– 603,– 772,– 1.000,– N N N N N 2) Derating acc. to catalogue D 83.1; efficiency class of MLFB unchanged. No surcharge if special voltage is chosen ( MLFB digit 11=9) Cooling water temperature max. 30 °C (consider power reduction) - power reduction acc. to derating table. No surcharge if special voltage is chosen ( MLFB digit 11=9) Cooling water temperature max. 35 °C (consider power reduction) - power reduction acc. to derating table. No surcharge if special voltage is chosen ( MLFB digit 11=9) Cooling water temperature max. 40 °C (consider power reduction) - power reduction acc. to derating table. No surcharge if special voltage is chosen ( MLFB digit 11=9) Cooling temperature less than +40 °C with increased rating -factory clarification required, not applicable at IE2 No surcharge if special voltage is chosen ( MLFB digit 11=9) Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 42 LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Selection and ordering data Special versions Additional Motor series identification code -Z with LOHER CHEMSTAR LOHER VARIO Surcharge / List price EURO Discount level A order code 1PS4. . . - . . . . . - . . . . -Z and plain text 1PS5. . . - . . . . . - . . . . -Z if required Special electrical designs / winding protection Utilization acc. to insulation class 155(F) - if DOL duty rating according IEC standard maximal. Discount level C Frame size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 355 C12 65,– 74,– 87,– 107,– 130,– 165,– 206,– 265,– 323,– 478,– 603,– 772,– 1.000,– N 400 N 450 N 500 N N No surcharge if special voltage is chosen (MLFB digit 11=9) Rated output of next smaller power in size - IEC rating steps will considered in combination with D06 to D18 C29 43,– 43,– 43,– 50,– 50,– 66,– 66,– 84,– 84,– 96,– 96,– 112,– 112,– 115,– N N N N Moderately extended speed range at inverter operation V82 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. Insulation class F W00 N N N N N N N N Insulation class H W01 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N N N N N N N 2.070,– 2.210,– 2.420,– 2.690,– 3.310,– 4.090,– 4.780,– N 4.150,– 5.750,– 7.500,– 9.750,– 433,– 433,– 433,– 473,– 502,– 876,– 1.570,– 1.690,– 2.060,– 2.710,– 3.690,– 4.780,– 5.980,– N a.A. a.A. a.A. a.A. 88,– N 88,– N 88,– N 88,– N 90,– N 106,– N 484,– N 564,– N 864,– N 1.170,– N 1.420,– N 2.100,– N 2.470,– N N N N 1.440,– N 1.440,– N 1.440,– N 1.440,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. No surcharge if special voltage is chosen ( MLFB digit 11=9) Reinforced winding isolation in case of inverter duty (Phase/Phase 2250V Peak / power reduction) - N N N N N N o.MP. o.MP. o.MP. o.MP. at LOHER CHEMSTAR MLFB digit 8=2 Sealing of the winding head with silicone rubber W03 Sealing of the cable duct with silicone rubber Abnormal voltage and/or frequency for separate fan drive motor W04 Y81 ● and identification code Other electrical designs Colors and paint finish Inner corrosion protection Loher coating system J08 W10 169,– 188,– 210,– 234,– 260,– 292,– 331,– 374,– 422,– 476,– Coating system N08 - 110µm (C3-medium) - Corrosion category acc. to EN/ISO 12944-5 = C3 V09 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. Coating system N14/J08 - 170µm (Chemical industry + On Shore, C5 - Industrial climate) - V10 276,– 315,– 358,– 406,– 460,– 523,– 600,– 686,– 782,– 890,– 1.010,– 1.150,– 1.300,– 1.470,– 1.440,– 1.440,– 1.440,– 1.440,– 231,– 269,– 313,– 361,– 415,– 475,– 542,– 617,– 703,– N N N N 536,– 603,– 679,– 764,– N N N N Corrosion category acc. to EN/ISO 12944-5 = C5 (5-15 years) for industrial climate Coating system N14A (Chemical + On Shore, C5 - Industry) - W14 108,– 127,– 148,– 172,– 199,– Special prime coat system Z05 with inner corrosion protection system J08 W15 338,– 376,– 419,– 467,– 521,– 584,– 661,– 747,– 843,– 951,– 1.170,– 1.550,– 2.010,– 2.410,– N N N N Coating system Z21/J08 - 210µm (Off Shore, C5M-M) - V11 553,– 629,– 716,– 812,– 919,– 1.050,– 1.200,– 1.370,– 1.570,– 1.780,– 2.120,– 2.630,– 3.240,– 3.810,– 3.500,– 3.500,– 3.500,– 4.000,– V19 108,– 127,– 148,– 172,– 199,– 231,– 269,– 313,– 361,– 415,– 475,– 542,– 617,– 703,– 1.440,– 1.440,– 1.440,– 1.440,– V12 923,– 1.000,– 1.090,– 1.180,– 1.380,– 1.510,– 1.760,– 1.930,– 2.120,– 2.340,– 2.770,– 3.280,– 3.980,– 4.740,– 8.500,– 8.500,– 8.500,– 10.000,– 658,– 1.080,– 1.190,– 1.460,– 1.680,– 2.040,– 2.960,– 3.760,– 5.500,– Corrosion category acc. to EN/ISO 12944-5 = C5 (5-15 years) for industrial climate Corrosion category acc. to EN/ISO 12944-5 = C5 (5-15 years) - sea-climate Increased layer thickness 275µm for coating system Z21 (C5M-high) - only in combination with V11 Corrosion category acc. to EN/ISO 12944-5 = C5 high (>15 years) - sea-climate Special offshore painting S13 related to NORSOK M501 ( C5M-high ) with comments and deviations Corrosion category acc. to EN/ISO 12944-5 = C5 high (>15 years) - sea-climate Special coating system S11/J08 (e. g. submerged motors) V13 5.400,– 5.500,– 5.500,– 5.500,– Without coating, but primed K24 22,– 22,– 29,– 29,– 29,– 46,– 46,– 86,– 86,– 86,– 86,– 86,– 86,– 98,– N N N Without coating K23 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N Outer painting for zink galvanized noise cabinet N08 (110µm) V98 Y50 ● and N N N N N N N N N N N N N N 3.600,– 3.900,– 4.200,– 4.500,– Paint Colours according Munsell or British Standard 478,– 478,– 478,– 507,– 556,– N N N N N N N N N N N N N N N 2.300,– 2.300,– 2.300,– 2.850,– 63,– 63,– 63,– 106,– 106,– 139,– 139,– 194,– 243,– 243,– 243,– 243,– 243,– 243,– 576,– 576,– 576,– 864,– 63,– 63,– 63,– 106,– 106,– 139,– 139,– 194,– 243,– 243,– 243,– 243,– 243,– 243,– 576,– 576,– 576,– 864,– identification code Standard coating in RAL1004,1018,2000,2004,5009,5012,5015,6003,6011,7000,7011,7031,7038,9002 Y53 ● and standard coating RAL… Special coating in RAL1004,1018,2000,2004,5009,5012,5015,6003,6011,7000,7011,7031,7038,9002 - Y54 ● und special specify special coating system in addition, e.g. V10, V11, W14, etc. coating RAL… RAL colours different to above indicated Y51 ● and special 95,– 95,– 95,– 159,– 159,– 209,– 209,– 291,– 365,– 365,– 365,– 365,– 365,– 365,– 1.150,– 1.150,– 1.150,– 1.700,– 212,– 212,– 212,– 212,– 212,– 278,– 278,– 388,– 486,– 486,– 486,– 486,– 486,– 486,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. coating RAL… Special colour not RAL Y71 ● and identification code Other painting combinations / systems or RAL colours to customer specification Design for Zones according to ATEX Design in gas group IIC, but stamped in IIB M99 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. Design for zone 21 (conductive dust) at mains operation M34 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. Design for zone 22 (non conductive dust) at mains operation M35 N N N N N N N N N N N N N N 2.000,– 2.250,– 2.500,– 3.000,– Design for zone 21 (conductive dust) at inverter operation M38 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. Design for zone 22 (non conductive dust) at inverter operation M39 W20 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. 122,– 122,– 122,– 134,– 153,– 168,– 353,– 353,– 395,– 411,– 427,– 444,– 461,– 479,– a.A. a.A. a.A. a.A. W21 342,– 342,– 342,– 383,– 401,– 417,– 601,– 679,– 721,– 736,– 752,– 769,– 785,– 802,– a.A. a.A. a.A. a.A. W22 135,– 135,– 135,– 148,– 168,– 185,– 388,– 388,– 435,– 452,– 469,– 488,– 507,– 527,– a.A. a.A. a.A. a.A. W23 376,– 376,– 376,– 421,– 441,– 458,– 661,– 747,– 793,– 810,– 828,– 845,– 864,– 882,– a.A. a.A. a.A. a.A. Design in double protection additionally for dust, Zone 22 at mains operation; no hybrid certification - N N N N non conductive dust Design in double protection additionally for dust, Zone 21 at mains operation; no hybrid certification design and certification for conductive dust (incl. non conductive dust) Design in double protection additionally for dust, Zone 22 at inverter operation; no hybrid certification non conductive dust; options for inverter operation choose separately Design in double protection additionally for dust, Zone 21 at inverter operation; no hybrid certification design and certification for conductive dust (incl. non conductive dust); options for inverter operation choose separately Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 43 LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code 1PS4. . . - . . . . . - . . . . -Z and plain text 1PS5. . . - . . . . . - . . . . -Z if required Discount level C Frame size 71 80 90 Design acc. to GL ( Germanischer Lloyd ), CT 45 °C with manufacturers declaration - non essential W24 168,– 168,– 168,– 100 168,– 112 168,– 132 168,– 160 168,– 180 168,– 200 236,– 225 236,– 250 300,– 280 436,– 315 776,– 355 a.A. 355 a.A. 400 a.A. 450 a.A. 500 a.A. Design acc. to LRoS ( Lloyds Register of Shipping ), CT 45 °C with manufacturers declaration - non essential W25 168,– 168,– 168,– 168,– 168,– 168,– 168,– 168,– 236,– 236,– 300,– 436,– 776,– a.A. a.A. a.A. a.A. a.A. Design acc. to BV ( Bureau Veritas ), CT 45 °C with manufacturers declaration - non essential W26 211,– 211,– 211,– 211,– 211,– 211,– 211,– 211,– 296,– 296,– 371,– 544,– 969,– a.A. a.A. a.A. a.A. a.A. Design acc. to DNV ( Det Norske Veritas ), CT 45 °C with manufacturers declaration - non essential W27 168,– 168,– 168,– 168,– 168,– 168,– 168,– 168,– 236,– 236,– 300,– 436,– 776,– a.A. a.A. a.A. a.A. a.A. Design acc. to ABS ( American Bureau of Shipping ) CT 50 °C with manufacturers declaration - non essential W28 211,– 211,– 211,– 211,– 211,– 211,– 211,– 211,– 296,– 296,– 371,– 544,– 969,– a.A. a.A. a.A. a.A. a.A. Design acc. to RINa ( Registro Italiano Novale ) CT 50 °C with manufacturers declaration - non essential W29 168,– 168,– 168,– 168,– 168,– 168,– 168,– 168,– 236,– 236,– 300,– 436,– 776,– a.A. a.A. a.A. a.A. a.A. Other certifications, motors for upper deck mounting and approvals to classification W99 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N Design acc to GL ( German Lloyd ), AT 45 °C, essential drive with manufacturers declaration1) Q60 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. Design acc to LRoS (Lloyds Register of Shipping), AT 45 °C, essential drive, manufacturers declaration1) Q61 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. Design acc to BV (Bureau Veritas), AT 45 °C, essential drive with manufacturers declaration1) Q62 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. Design acc to DNV (Det Norske Veritas), AT 45 °C, essential drive with manufacturers declaration1) Q63 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. Design acc to ABS (American Bureau of Shipping), AT 50 °C, essential drive, manufacturers declaration1) Q64 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. Design acc to RINa (Registro Italiano Novale), AT 50 °C, essential drive, manufacturers declaration1) Q65 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q66 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. Design acc to USSR (Russia), essential drive with manufacturers declaration Q67 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. Design acc to PR (Poland), essential drive with manufacturers declaration1) Q68 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. Design acc to NKK (Japan), essential drive with manufacturers declaration1) Q69 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. Operation at ambient temperatures down to -50°C and transport down to -50°C - antifriction bearings D02 N N N N N N N N N N N N N N 7.200,– 9.500,– 12.000,– 16.000,– Operation at ambient temperatures down to -40°C and transport down to -40°C - antifriction bearings D03 N N N N N N N N N N N N N N 3.600,– 4.800,– 5.900,– 8.000,– Operation at ambient temperatures down to -30°C and transport down to -40°C - antifriction bearings D04 N N N N N N N N N N N N N N 1.800,– 2.400,– 3.000,– 4.000,– Electric design according to NEMA MG1-12 D30 N N N N N N N N N N N N N N 1.440,– 1.440,– 1.440,– 1.440,– Certificate according NEPSI - design may differ (different cover size) D32 163,– 163,– 163,– 219,– 219,– 219,– 230,– 230,– 335,– 348,– 348,– 348,– 348,– N 1.470,– 1.470,– 1.470,– 1.470,– China Energy Efficiency Label D34 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N Certificate EAC for Eurasien Customs Union D35 163,– 163,– 163,– 219,– 219,– 219,– 230,– 230,– 335,– 348,– 348,– 348,– 348,– 348,– 1.470,– 1.470,– 1.470,– 1.470,– Ex-Certification for India (PESO - CCOE) IEC Ex Certificate D38 163,– 163,– 163,– 219,– 219,– 219,– 230,– 230,– 335,– 348,– 348,– 348,– 348,– 348,– 1.470,– 1.470,– 1.470,– 1.470,– D37 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 588,– 588,– 588,– Terminal box on right hand side ( view onto DE ) K09 N N N N N 247,– 260,– 380,– 409,– 482,– 793,– 1.100,– 1.390,– a.A. Terminal box on left hand side ( view onto DE ) K10 793,– 1.100,– 1.390,– Terminal box on top K11 □ □ Terminal boxes in IP65 Q71 Cable entry thread metrically different from the standard - thread dimension must be given W30 45,– 45,– 45,– 45,– 45,– 52,– 52,– 52,– 52,– 52,– 65,– 65,– 65,– 65,– Enlarged connecting for main terminal box - not in combination with K53 (Ex d-terminal box) L00 428,– 428,– 617,– 805,– 993,– 1.180,– 1.370,– 1.560,– 1.750,– 1.940,– 2.120,– 2.310,– 2.500,– 2.690,– Undrilled cable gland plate at main terminal box L01 N N N N N N N N N N N N N N Main terminal box in Exd-design with standard terminal studs Q31 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. 1 x NPT - thread for mains supply ( observe the sizes ) - describe thread, cable gland not in our supply W32 113,– 113,– 113,– 113,– 113,– 130,– 130,– 130,– 130,– 130,– 163,– 163,– 163,– 163,– a.A. a.A. a.A. a.A. 1 x cable gland standard for not armoured cable - for main terminal box K54 55,– 55,– 55,– 78,– 78,– 78,– 112,– 112,– 212,– 212,– 249,– 249,– 249,– 249,– One cable gland standard thread size for auxiliary connection 1 pc. (not armoured cable) W33 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– N N N N Clamp terminal for connection without cable lug W35 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. Special cable gland - one cable gland for mains connection, Y97 ● and not armoured cable, exact cable data needed identification code Cable gland standard in Ex d (not armoured cable) 1 pc. - only in combination with K53, W91 Ship design "Operation below deck" 1) Design acc to CCS (China), AT 45 °C, essential drive with manufacturers declaration 1) Individual certifications 588,– Special mechanical designs N □ N □ N N □ N N □ N N □ N 247,– □ N 260,– □ N 380,– □ N 409,– □ N 482,– □ N □ N N N □ □ o.MP. □ a.A. o.MP. o.MP. o.MP. o.MP. o.MP. N 1.150,– 1.150,– 1.150,– 1.150,– □ N □ N N N □ N N □ N o.MP. N N □ N o.MP. N □ N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. 71,– 71,– 71,– 110,– 110,– 110,– 149,– 149,– 350,– 350,– 665,– 665,– 665,– 665,– N N N N exact cable data needed Cable gland for auxiliaries Ex d - 1 pc. ( not armoured cable ) W92 71,– 71,– 71,– 71,– 71,– 71,– 71,– 71,– 71,– 71,– 71,– 71,– 71,– 71,– N N N Main terminal box flameproof Ex d II C K53 928,– 928,– 928,– 928,– 928,– 1.210,– 1.210,– 1.790,– 1.790,– 1.790,– 2.060,– 2.060,– 3.320,– 3.320,– 3.450,– 3.450,– 3.450,– 3.450,– Additional terminal box Ex d II C made of grey cast iron - with standard threats according catalogue; V43 N N N N N N N N 1.840,– 1.840,– 1.840,– 1.840,– 2.320,– 2.320,– 1.150,– 1.150,– 1.150,– 1.150,– N if thread differ please select (W30), due reducer for cable glands limited if Ex d. Additional terminal box Ex e - design / grey cast iron - not in combination with K53 (Ex d-terminal box) W72 N N N N N 220,– 220,– 220,– 678,– 678,– 678,– 698,– 698,– 698,– a.A. a.A. a.A. a.A. Auxiliary terminal box-material: stainless steel - not in combination with K53 (Ex d-terminal box) M51 N N N N N N N N N N N N N N 1.150,– 1.150,– 1.150,– 1.150,– Separate auxiliary box terminal for space heater M52 N N N N N N N N N N N N N 698,– 576,– 576,– 576,– 576,– Auxiliary terminal box in cast iron design with removable gland plate "undrilled" - not in combination Q75 N N N N N N N N N N N N N N 576,– 576,– 576,– 576,– Q76 N N N N N N N N N N N N N N 864,– 864,– 864,– 864,– with K53 (Ex d-terminal box) Auxiliary terminal box in cast iron design with removable gland plate "metric thread drilled and sealed with metal plug" - not in combination with K53 (Ex d-terminal box) 1) Acceptance tests must be selected additionally. For example, for the first motor select F83 or F93, and for each additional motor F01. Inclusive of costs for certification authority and inspector, and shaft test if specified by certification authority. LOHER CHEMSTAR for essential drive is possible on request as an ETO option (Engineer To Order) without an option code. Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 44 LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Selection and ordering data Special versions Additional Motor series identification code -Z with LOHER CHEMSTAR LOHER VARIO Surcharge / List price EURO Discount level A order code 1PS4. . . - . . . . . - . . . . -Z and plain text 1PS5. . . - . . . . . - . . . . -Z if required Discount level C Frame size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Special mechanical designs Cable led out radially without terminal box with 1m free cable length (4- or 7-core) W38 N N N N N 679,– 765,– 851,– 937,– 1.020,– 1.110,– 1.190,– 1.280,– a.A. N N N N Surcharge each further meter of cable - only in combination with W38 W39 N N N N N 67,– 91,– 112,– 162,– 162,– 179,– 179,– 179,– a.A. N N N N Connection cable for auxiliaries - only in combination with W38, cable length as main supply W40 N N N N N 408,– 408,– 408,– 408,– 408,– 408,– 408,– 408,– a.A. N N N N Additional separately supplied terminal box made of grey-cast iron with baseplate - main terminal box W41 N N N N N 284,– 284,– 284,– 436,– 436,– 536,– 536,– 536,– a.A. N N N N Cable entry side DE K83 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. Cable entry side NDE K84 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. Turn of the terminal box about 180° K85 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. certificate acc. Ex e K01 □ □ □ □ □ □ □ Vibration severity grade B - IEC 60034-14 - if inverter duty for smallest and highest speed of speed range only K02 418,– 456,– 516,– 569,– 576,– 620,– 620,– 629,– 673,– 798,– 980,– 1.150,– 1.470,– 2.580,– 1.500,– 2.250,– 3.000,– 3.750,– Shaft and flange with increased precision to DIN42955-R K04 149,– 149,– 149,– 149,– 149,– 200,– 262,– 367,– 478,– 576,– 700,– 871,– 1.020,– a.A. 2.000,– 2.250,– 2.500,– 3.000,– Radial sealing ring on DE-side for flange-mounted types (oil-tight) horizontal mounting K17 51,– 53,– 58,– 66,– 68,– 75,– 92,– 110,– 143,– 205,– 262,– 338,– 402,– a.A. N N N N Radial sealing ring on DE-side for vertical flange-mounted types (oil-tight) W43 92,– 94,– 104,– 119,– 122,– 135,– 166,– 197,– 256,– 369,– 478,– 607,– 722,– a.A. N N N Labyrinth sealing for external bearing seal W44 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. 698,– 889,– 1.140,– 1.320,– 2.180,– Bearing for increased lateral forces (roller bearing DE) including regreasing device - including K40 K20 N N N N N N 519,– 572,– 632,– 691,– 714,– 738,– 369,– a.A. Axial thrust bearing □ V20 □ N □ N □ □ □ □ □ N N N N K40 N N N N N N 419,– 472,– 532,– 591,– 614,– 638,– L27 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. 2.100,– 2.230,– 2.340,– Shaft earthing device - down to -20°C V36 N □ N □ N □ Regreasing device DE/NDE N N □ Bearing insulation NDE for antifriction bearing - binding for frame size 315 - 500 at inverter operation □ N □ o.MP. Vibration severity grade A - IEC 60034-14 N □ N □ N □ N □ N □ N N □ N N □ N N □ □ a.A. □ a.A. N □ a.A. a.A. N N a.A. a.A. a.A. a.A. □ □ □ □ □ □ 2.430,– 2.550,– 1.800,– 2.000,– 2.000,– 2.000,– N □ □ N □ N □ a.A. □ a.A. □ a.A. □ a.A. □ Fixed bearing DE K94 Fixed bearing NDE L04 N N 189,– 189,– 194,– 210,– 233,– 273,– 310,– 340,– 378,– 431,– 536,– a.A. N N N N PT100 bearing in tolerance class A with calibration certificate - only in combination with Q44 V76 N N N N N N N N N N N N N N 2.300,– 2.300,– 2.300,– 2.300,– Bearing ventilation at DE for lower bearing temperature for antifriction bearing design grease lubricated V17 N N N N N N N N N N N N N N 2.850,– 3.200,– 3.450,– 3.700,– Bearing insulation DE- and NDE (DE linked to earth) for antifriction bearing design - V18 N N N N N N N N N N N N N N 5.150,– 5.150,– 5.760,– 5.760,– Grease extractors for DE and NDE V21 N N N N N N N N N N N N N N N N N 3.450,– Automatic grease lubricator DE and NDE (suitable for ambient temperature from -15 up to + 50°C) V22 N N N N N N N N N N N N N N 2.850,– 2.850,– 2.850,– 2.850,– Enlarged grease chamber DE and NDE V25 N N N N N N N N N N N N N N 1.750,– 1.750,– 2.300,– 2.300,– External earthing ( additionally ) W46 110,– 110,– 110,– 110,– 114,– 114,– 125,– 143,– 231,– 271,– 300,– N N N N VIK design - incl. W14, W69 K30 W09 212,– 260,– 310,– 363,– 419,– 479,– 546,– 618,– 695,– 778,– 867,– 963,– 1.070,– N 3.000,– 4.000,– a.A. N 480,– 528,– 578,– 657,– 713,– 773,– 840,– 983,– 1.060,– 1.140,– 1.230,– 1.330,– 1.540,– N N N N N Second rating plate separately K31 22,– 22,– 22,– 22,– 22,– 22,– 22,– 70,– 70,– 70,– 70,– 70,– 70,– 70,– 288,– 288,– 288,– 288,– Second rating plate installed in terminal box Additional plate with data at inverter duty - data for quadratic torque speed range 1:10 W47 Y80 ● and and constant torque in speed range 1:3 and 1:10 identification code Additional plate for customer data (each plate) - data / text have to be give with order Y82 ● and horizontal mounting only, (vertical mounting on request) LOHER CHEMSTAR Plus design, including VIK design; IP56 - including K30, K51, W14, W69 and 155,– 182,– 204,– IP66 shaft sealing, vibration grade similar grade B 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 288,– 288,– 288,– 288,– o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N 144,– 43,– 43,– 43,– 43,– 43,– 43,– 43,– 71,– 71,– 71,– 89,– 89,– 112,– 115,– 144,– 144,– 144,– Additional data on motor rating plate and on packing sticker - max. 20 digits Y84 43,– 43,– 43,– 43,– 43,– 43,– 43,– 71,– 71,– 71,– 89,– 89,– 112,– 115,– N N N Plates made of stainless steel W48 W49 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– 70,– 70,– 70,– 70,– 70,– 70,– N N N N Plates in other languages as German or English - mains rating plate or auxiliary plate, 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.150,– 1.150,– 1.150,– 1.150,– factory clarification required Additional measures for 2 up to 4 years storage to storage instructions W50 45,– 45,– 45,– 54,– 65,– 78,– 97,– 106,– 118,– 137,– 143,– 203,– 220,– 300,– 864,– 864,– 864,– 1.150,– identification code Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 45 N LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Selection and ordering data Special versions Additional Motor series identification code -Z with LOHER CHEMSTAR LOHER VARIO Surcharge / List price EURO Discount level A order code 1PS4. . . - . . . . . - . . . . -Z and plain text 1PS5. . . - . . . . . - . . . . -Z if required Discount level C Frame size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Special mechanical designs Space heater 230 V - preferably choose M13 K45 458,– 458,– 458,– 512,– 545,– 569,– 800,– 891,– 979,– 1.120,– 1.240,– 1.400,– 1.400,– N 2.250,– 2.500,– 2.750,– 3.000,– Space heater 115 V - preferably choose M12 K46 458,– 458,– 458,– 512,– 545,– 569,– 800,– 891,– 979,– 1.120,– 1.240,– 1.400,– 1.400,– N 2.500,– 2.750,– 3.000,– 3.250,– Space heater 110 - 120 V (min. 100 V, max. 132 V) M12 458,– 458,– 458,– 512,– 545,– 569,– 800,– 891,– 979,– 1.120,– 1.240,– 1.400,– 1.400,– 1.570,– 2.000,– 2.000,– 2.400,– 2.800,– Space heater 210 - 250 V (min. 200 V, max. 264 V) M13 458,– 458,– 458,– 512,– 545,– 569,– 800,– 891,– 979,– 1.120,– 1.240,– 1.400,– 1.400,– 1.570,– 2.000,– 2.000,– 2.400,– 2.800,– Space heater rated voltage 110-120 V (min. 100 V, max. 132 V) Ex e II T 3 M14 N N N N N N N N N N N N N N 3.000,– 3.000,– 3.300,– 3.600,– Space heater rated voltage 220-240 V (min. 200 V, max. 264 V) Ex e II T 3 M15 N N N N N N N N N N N N N N 3.000,– 3.000,– 3.300,– 3.600,– Heater in main terminal box - 1PS5. . . - . . . . . - . . . . -Z P84 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. 3.500,– 3.500,– 3.500,– 3.500,– 4.000,– 4.500,– 5.250,– 6.000,– 1PS4. . . - . . . . . - . . . . -Z P84 Second standard shaft end - VARIO for 50% torque, CHEMSTAR for 100% torque3) K16 258,– Second shaft end for IMB3 up to 100% torque; cylindrical with key Q21 Y55 ● and N N N N N N N N N N N N N N 5.500,– 6.200,– 6.800,– 7.700,– Non-standard cylindrical shaft end (diameter identical or smaller as standard)- 273,– 293,– 329,– 380,– 450,– 502,– 595,– 680,– 764,– 904,– 1.010,– 1.140,– 1.350,– 2.070,– 1.150,– 1.150,– 1.150,– 1.350,– in case of significant different diameter, especially high pole motors due high torque stress, identification factory clarification required 3) 260,– 278,– 296,– 324,– 378,– 451,– 544,– 640,– 747,– 860,– 1.020,– 1.240,– a.A. code 3) W51 687,– 704,– 704,– 704,– 749,– 771,– 1.070,– 1.070,– 1.350,– 1.470,– 1.580,– 1.580,– 1.580,– 2.200,– N N N N Shaft of material 1.4021 3) W52 756,– 756,– 756,– 756,– 787,– 1.010,– 1.500,– 1.780,– 2.010,– a.A. a.A. a.A. a.A. a.A. N N N N W53 1.480,– 1.480,– 1.480,– 1.480,– 1.600,– 1.940,– 2.170,– 2.170,– 2.760,– a.A. Shaft of material 1.7225 3) = Basis 1 - 4 pcs. / calculate factor 0.5 for basis > 5 - 19 pcs. ! Shaft end of special steel butt-welded ( Material 1.4571 ) a.A. N Shaft material of alloy steel (1.7225 - 42CrMo4) - only until -40°C L72 N N N N N N N N N N N N N N 2.200,– 3.000,– 3.800,– 4.600,– Welded standard stator housing for TEFC motors - factory clarification is mandatory, W54 N N N N a.A. a.A. 4.470,– 6.020,– 6.560,– 7.090,– a.A. 7.090,– a.A. 7.090,– a.A. 8.160,– a.A. □ □ N □ N □ N Welded CU-rotor ( copper-bar rotor ) W55 N N N N N a.A. 2.910,– 3.110,– 4.220,– 5.270,– 5.560,– 7.310,– 10.300,– a.A. □ □ □ □ Special rotor for heavy duty starting (e.g. DS-rotor or brass cage rotor) - type test needed Q22 N N N N N N N N N N N N N N 4.300,– 5.000,– 5.750,– Asynchronous generator design with 1.8 fold runaway speed - 4 pole or higher pole, only W56 N N 109,– 134,– 163,– 206,– 258,– 331,– 404,– 598,– 754,– 965,– 1.250,– a.A. Enclosure IP56 K51 268,– 268,– 268,– 294,– 294,– 294,– 294,– 364,– 364,– 364,– 364,– 364,– 476,– 622,– □ □ □ □ Enclosure IP65 - 1PS5. . . - . . . . . - . . . . -Z K50 295,– 295,– 295,– 323,– 323,– 323,– 323,– 401,– 401,– 401,– 401,– 401,– 523,– 684,– 2.790,– 3.270,– 3.720,– 4.530,– dimensions may differ 1PS4. . . - . . . . . - . . . . -Z K50 N 1.350,– N 3.270,– 6.650,– N 3.720,– N 3.350,– Enclosure IP66 L94 369,– 369,– 369,– 404,– 404,– 404,– 404,– 501,– 501,– 501,– 501,– 501,– 654,– 855,– a.A. a.A. a.A. a.A. Increased tropicalization, humidity≥ 80% - LOHER CHEMSTAR incl. V10 and W71, W61 437,– 485,– 543,– 630,– 702,– 830,– 980,– 1.100,– 1.250,– 1.390,– 1.600,– 1.880,– 2.220,– 2.610,– 2.000,– 2.300,– 2.600,– 2.900,– 2.900,– LOHER VARIO incl. V10 and P45 Tropical design for outdoor onshore installation L28 N N N N N N N N N N N N N N 2.000,– 2.300,– 2.600,– Design without fan and fan cover - motor mounted in air stream; without external air stream cooling W62 132,– 132,– 132,– 132,– 132,– 132,– 132,– 186,– 186,– 186,– 227,– 227,– 227,– a.A. a.A. a.A. a.A. a.A. W63 60,– 78,– 95,– 113,– 130,– 148,– 165,– 183,– 200,– 218,– 235,– 253,– 270,– 315,– 700,– 850,– 980,– 1.100,– factory clarification required, due reduced rating Outer fan with corrosion protection in case of metal fan □ Fan of aluminium W64 100,– 129,– 158,– 188,– 217,– 246,– 275,– 304,– 333,– 363,– N N Fan of steel W65 a.A. a.A. a.A. a.A. a.A. 1.170,– 1.170,– 1.360,– 1.360,– 1.690,– 1.690,– 1.690,– 1.710,– o.MP. Outer-fan of brass - 1PS5. . . - . . . . . - . . . . -Z W66 a.A. a.A. a.A. a.A. a.A. 1.520,– 1.520,– 1.770,– 1.770,– 2.220,– 2.220,– 2.220,– 2.220,– 2.890,– N N N N N N N N N N N N N N N 1PS4. . . - . . . . . - . . . . -Z W66 Outer fan of stainless steel - 1PS5. . . - . . . . . - . . . . -Z N N N □ □ □ 1.750,– 1.750,– 1.750,– 1.750,– V94 1PS4. . . - . . . . . - . . . . -Z V94 N □ 1.750,– 2.000,– 2.250,– 2.500,– 4.500,– 5.000,– 5.500,– a.A. 4.500,– 5.000,– 5.500,– 6.000,– Special ventilation for on deck motors W67 N N N 2.730,– 2.730,– 2.780,– 2.910,– 2.910,– 2.960,– 3.040,– a.A. Fan cover of steel sheet (3 mm thickness) W68 a.A. a.A. a.A. a.A. 1.360,– 1.360,– 1.360,– 1.360,– 1.360,– 1.360,– 1.360,– 1.360,– 1.430,– 1.930,– a.A. a.A. a.A. a.A. Galvanized fan cowl - in K30 and W09 incl. W69 104,– 133,– 162,– 191,– 219,– 248,– 277,– 306,– 335,– 364,– 392,– 421,– 450,– N a.A. a.A. a.A. a.A. Noise level 3 for rotation CW seen on DE - only for 2-pole motors K37 N N N N N 767,– 767,– 767,– 767,– 778,– 811,– 878,– 956,– Noise level 3 for rotation CCW seen on DE - only for 2-pole motors K38 N N N N N 767,– 767,– 767,– 767,– 778,– 811,– 878,– 956,– N N N N N Clockwise rotation viewed to DE - direction of rotation is mandatory for motors frame size 355 in 2-/4-pole design K97 N N N N N N N N N N N N N o.MP. o.MP. o.MP. o.MP. o.MP. Anti-clockwise rotation viewed to DE - direction of rotation is mandatory for motors frame size 355 in 2-/4-pole N N N N a.A. N a.A. N a.A. N a.A. N K98 N N N N N N N N N N N N N o.MP. o.MP. o.MP. o.MP. o.MP. Noise reduction: silencer for air inlet (GG3) - only in combination with K97 or K98 L20 N N N N N N N N N N N N N 2.930,– 2.200,– 3.080,– 4.000,– 4.000,– Stainless steel grid for air inlet silencer - only in combination with L20 L25 N N N N N N N N N N N N N N 576,– 576,– 576,– 576,– Noise cabinet with inspection door - zinc galvanized unpainted - noise reduction approx. 15dB(A) based on GG1 V32 N N N N N N N N N N N N N N 18.500,– 20.500,– 22.400,– 25.000,– Noise cabinet with inspection door - V4A unpainted - noise reduction approx. 15dB(A) based on GG1 V35 N N N N N N N N N N N N N N a.A. a.A. a.A. Noise jacket, noise reduction approx. 3-5 dB(A) compared to standard GG1 Operation for both rotations - from 355 in 2-/4-pole increased noise level and reduced power V34 Increased switching cycles (max. 3000 starts per year Q23 design Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. K99 N □ N □ N N □ N N N □ N □ N N 46 N □ N □ N N □ N N □ N N □ N N □ N N □ N N □ N N a.A. N a.A. a.A. a.A. a.A. a.A. 3.000,– 3.850,– 4.750,– a.A. N 2.150,– 2.900,– 3.550,– 4.750,– LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code 1PS4. . . - . . . . . - . . . . -Z and plain text 1PS5. . . - . . . . . - . . . . -Z if required Discount level C Frame size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Special mechanical designs Balancing with full key L68 99,– 99,– 114,– 114,– 114,– 132,– 132,– 166,– 166,– 207,– 207,– 207,– 207,– 207,– 1.440,– 1.440,– 1.440,– 1.440,– L15 N N N N N N N N N N N N N N 2.000,– 2.000,– 2.000,– 2.000,– 3.000,– 3.000,– 3.000,– 3.500,– L17 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. 2.300,– 2.300,– 2.300,– 3.450,– Machine mounting: bolts, shims and tapered pins for mounting on steel foundation L31 N N N N N N N N N N N N N N 2.000,– 2.300,– 2.600,– 2.900,– Machine mounting: anchor bolts, sole plates and SS-shims for fixing on concrete base L33 N N N N N N N N N N N N N N 5.750,– 6.000,– 6.300,– 6.800,– Half key balancing L69 N N N N N N N N N N N N N N □ □ □ □ Stainless steel screws and plates W71 160,– 170,– 185,– 224,– 242,– 307,– 380,– 413,– 464,– 500,– 584,– 738,– 920,– 1.150,– N N N N Stainless steel external bolts P45 N N N N N N N N N N N N N N 1.150,– 1.400,– 1.650,– 1.900,– Ambient temperature to -40°C; preheating before operation necessary - due needed heater power W73 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. Support ring for coupling guard - 1PS5. . . - . . . . . - . . . . -Z 1PS4. . . - . . . . . - . . . . -Z L15 Fitting of coupling half (customer-supplied, ready machined and balanced) - supplied 4 weeks ahead testing date factory clarification required, heating via winding may be needed. Installed heating elements for surcharge. Ambient temperature to -60°C; preheating before operation necessary - due needed heater power W74 N N N N N N N N N N N N a.A. a.A. N N N N W97 238,– 238,– 325,– 413,– 500,– 588,– 675,– 763,– 850,– 938,– 1.030,– 1.110,– 1.200,– 1.290,– N N N N N factory clarification required, heating via winding may be needed. Installed heating elements for surcharge. Ambient temperature to -40°C; without preheating before starting Ambient temperature to -55°C; without preheating before starting W98 1.110,– 1.110,– 1.190,– 1.280,– 1.400,– 1.630,– 2.020,– 2.330,– 2.690,– 3.200,– 3.760,– 4.510,– 5.490,– 6.070,– N N N Mounted pulse transmitter 1024 pulses/rpm - 10 - 30 V, HTL - level - flameproof design W96 N N N N N 7.910,– 7.910,– 7.910,– 7.910,– 8.420,– 8.420,– 9.110,– 9.400,– 9.400,– N N N N Speed encoder Ex design (preferred brand) - 1024 pulses/rpm - 10 - 30 V, HTL - level - flameproof design V72 N N N N N N N N N N N N N N 5.760,– 5.760,– 5.760,– 5.760,– Speed encoder Ex-design with integrated shaft earthing device (Loher preferred brand) - 1024 pulses/rpm - N N N N N N N N N a.A. a.A. a.A. a.A. 1.150,– 1.150,– 1.150,– 1.150,– V77 N N N N N Mechanical protection for speed encoder - in combination with V72, V77 M68 N N N N N N N N N N N N N N Mounted forced ventilation axial - forced ventilation is to define preferably by 10. item of MLFB G17 N N N N N 3.300,– 3.760,– 4.100,– 4.350,– 4.520,– 4.710,– 4.960,– 5.310,– a.A. N N N N Mounted forced ventilation radial W81 N N N N N N N N N a.A. a.A. a.A. a.A. a.A. N N N N Forced ventilation NDE - for Ex motors - axial forced ventilation V28 N N N N N N N N N N N N N N 4.200,– 4.700,– 5.200,– 5.700,– Reverse lock for direction of rotation right seen onto DE ( left locked ) - dimensions may differ G48 N N N N N 2.380,– 2.620,– 2.620,– 2.780,– 3.020,– 3.760,– 4.560,– 4.780,– a.A. 5.760,– 6.500,– 7.200,– 8.650,– Reverse lock for direction of rotation left seen onto DE ( right locked ) - dimensions may differ G49 N N N N N 2.380,– 2.620,– 2.620,– 2.780,– 3.020,– 3.760,– 4.560,– 4.780,– a.A. 5.760,– 6.500,– 7.200,– 8.650,– Mechanical hand release for standard brake K82 N 651,– 651,– 651,– 651,– 651,– 678,– 678,– 838,– N N N N N N N N N 10 - 30 V, HTL - level - flameproof design; down to -20°C only; bearing insulation to be added Brake supply voltage AC 400 V/50 Hz 1-phase C01 N 82,– 82,– 82,– 82,– 82,– 82,– 82,– 82,– N N N N N N N N N Brake supply voltage DC 24 V C00 N 61,– 61,– 61,– 61,– 61,– 61,– 61,– 61,– N N N N N N N N N Tapered shaft end with shaft nut T36 N 9.500,– Micro switch for brake - mandatory for Ex motors or monitoring by other devices W83 N Sun protection shield - fixing parts of mild steel, cover of SS unpainted for vertical motors V87 N N N N N a.A. a.A. a.A. Sun protection shield - fixing parts of mild steel, cover of SS unpainted for horizontal motors V99 N N N N N a.A. a.A. a.A. Preparation for SPM bearing monitoring, only thread M8 for adapter W84 N N N N N 287,– 287,– Drain & breather for auxiliary terminal box IP56 - not in combination with V43 (Ex d terminal box) Q77 N N N N N N N Drain & breather for main terminal box IP56 - not in combination with K53 (Ex d terminal box) Q78 N N N N N N Machined surface on motor feet with dowel pin holes Q94 N N N N N Base frame for height adaptation of max. 2 frame sizes difference Q96 N N N N N Adaptation of foot- & shaft dimensions to next higher frame size (no terminal box adaptation!) Q97 N N N N N Adaptation of flange dimensions and flansh fixing holes Provisioned for lateral installation of sun shield Q98 N N N N Q99 N N N N Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. N □ N □ N □ 47 N N N N N N 9.500,– 9.500,– 9.500,– o.MP. o.MP. o.MP. o.MP. N N N N N a.A. a.A. a.A. a.A. a.A. a.A. 5.750,– 6.500,– 7.250,– 8.000,– a.A. a.A. a.A. a.A. a.A. a.A. 5.500,– 5.750,– 6.000,– 6.500,– 287,– 287,– 287,– 287,– 287,– 287,– 373,– 864,– 864,– 864,– 864,– N N N N N N N 576,– 576,– 576,– 576,– N N N N N N N N 576,– 576,– 576,– 576,– N N N N N N N N N 1.730,– 1.730,– 1.730,– 1.730,– N N N N N N N N N 11.500,– 11.500,– 13.000,– 14.500,– N N N N N N N N N 5.500,– 6.500,– 7.500,– 8.500,– N N N N N N N N N N 3.500,– 4.800,– 5.900,– 7.000,– N N N N N N N N N N 2.850,– 2.850,– 2.850,– 3.450,– □ N □ N □ N □ N □ LOHER CHEMSTAR and VARIO 1PS4 and 1PS5 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code 1PS4. . . - . . . . . - . . . . -Z and plain text 1PS5. . . - . . . . . - . . . . -Z if required Discount level C Frame size 71 80 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Special mechanical designs SPM bearing monitoring: Measuring nipple system 32 - thread M8, DE + NDE G50 N N N N N 621,– 1.150,– 1.150,– 1.150,– 1.150,– Shock pulse measurement (SPM), fixed sensor and distribution box H05 N N N N N N N N N N N N N N 4.000,– 4.000,– 4.000,– 4.000,– SPM bearing monitoring: Transducer system 40 - thread M8 W85 N N N N N a.A. a.A. a.A. a.A. a.A. a.A. 7.070,– 7.070,– 8.310,– N N N N Bearing temperature monitoring with PTC thermistors on DE/NDE W86 N N N N N N a.A. a.A. 1.800,– 1.800,– 1.800,– 1.800,– 1.800,– 1.800,– N N N N Speed monitoring by inductive proximity switches, Fa. Pepperl + Fuchs A03 N N N N N N N N N N N N N N 2.300,– 2.300,– 2.300,– 2.300,– 2 single RTD's PT100 for antifriction bearing - 3 or 4 wire from terminal box, rolling-contact bearing - A40 N N N N N N N N N N a.A. a.A. a.A. a.A. 1.440,– 1.440,– 1.440,– 1.440,– 478,– 478,– 478,– 478,– 478,– 478,– 478,– 478,– 1 x DE and 1 x NDE 2 double resistance thermometers PT100 for 4-wire connection from terminal box, rolling-contact bearing - A42 N N N N N N N N N N N N N 3.000,– 2.300,– 2.300,– 2.300,– 2.300,– 2 capillary dial-type thermometers without contacts A70 N N N N N N N N N N N N N N 2.300,– 2.300,– 2.300,– 2.300,– 2 capillary dial-type thermometers with 2 normally open contacts A71 N N N N N N N N N N N N N N 3.450,– 3.450,– 3.450,– 3.450,– Bearing temperature monitoring with 1 x PT100 each bearing in 2-wire connection - 2-wire from terminal box A72 N N N N N N N N 2.240,– 2.240,– 2.240,– 2.240,– 2.240,– 2.240,– N N N N One dial type thermometer with 2 contacts, capillary principle - Ex i design without supply unit V89 N N N N N N N N N N N N N N 2.600,– 2.600,– 2.600,– 2.600,– Engraved tag plate fixed on terminal box V96 N N N N N N N N N N N N N N 288,– 288,– 288,– 288,– Shims of SS-material (V4A/AISI316) - 4mm/motor foot - not laminated Q92 N N N N N N N N N N N N N N 1.730,– 1.730,– 1.730,– 2.000,– Shims of brass material - 4mm/motor foot - not laminated V31 N N N N N N N N N N N N N N 1.440,– 1.440,– 1.440,– 2.150,– Slotted feet holes Q95 N N N N N N N N N N N N N N 1.730,– 1.730,– 1.730,– 1.730,– Form coil winding LV-motors V01 N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. 2 metal test sheets (100 x 150mm) with paint layer for special paint inspection V08 N N N N N N N N N N N N N N 1.150,– 1.150,– 1.150,– 1.150,– Impact protection - for accessory equipment, per equipment M81 N N N N N N N N N N N N N N 720,– 720,– 720,– 720,– "High-Speed-Motors" for speed range 3600 < N <= 6000 RPM, factory clarification required torque W87 N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N B15 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. Extension of liability of defects of 12 to 24 months Q80 39,– 42,– 48,– 62,– 76,– 100,– 153,– 198,– 260,– 329,– 409,– 568,– 1.040,– 2.130,– 1.580,– 2.120,– 2.610,– 3.500,– Extension of liability of defects of 18 to 30 months Q81 60,– 64,– 74,– 96,– 117,– 155,– 236,– 306,– 401,– 508,– 632,– 877,– 1.610,– 3.290,– 2.440,– 3.270,– 4.030,– 5.410,– Extension of liability of defects of 24 to 36 months Q82 77,– 83,– 96,– 124,– 152,– 201,– 306,– 396,– 519,– 658,– 818,– 1.140,– 2.080,– 4.260,– 3.160,– 4.230,– 5.220,– 7.010,– Extension of liability of defects of 30 to 42 months Q83 109,– 117,– 136,– 175,– 214,– 283,– 431,– 7.350,– 9.870,– Extension of liability of defects of 36 to 48 months Extension of liability of defects of 48 to 60 months Q84 141,– 151,– 175,– 226,– 276,– 365,– 556,– 720,– 944,– 1.200,– 1.490,– 2.060,– 3.780,– 7.750,– 5.740,– 7.700,– 9.490,– 12.700,– Q85 197,– 212,– 245,– 316,– 386,– 511,– 779,– 1.010,– 1.320,– 1.670,– 2.080,– 2.890,– 5.290,– 10.900,– 8.040,– 10.800,– 13.300,– 17.800,– 1 x DE and 1 x NDE characteristic and nominal frequency adjusted design, performance test of original system may be needed "High-Speed-Motors" for speed range >6000 RPM, factory clarification required torque characteristic and nominal frequency adjusted design, performance test of original system may be needed; ETO-Option (Engineer To Order) without order code Retrofit (description of the special design separately) - adaptation to an existing motor Extension of the liability for defects □ = Standard version o.MP. = Without surcharge ● = This order code only determines the price of the version - additional plain text is required. a.A. = On request N = Not available Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 48 558,– 732,– 927,– 1.150,– 1.600,– 2.930,– 6.010,– 4.450,– 5.970,– LOHER CHEMSTAR and VARIO 1PS1 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE2, 0,75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Non-sparking" in accordance with EN 60079-15; 2010: CE 0102 II 3G Ex nA IIC T3 Gc Prated 60Hz kW FS kW IE class 2-pole: 3000 rpm at 50Hz LOHER CHEMSTAR 1,5 90 L 1,8 IE2 2,2 90 L 2,6 IE2 3 100 L 3,6 IE2 4 112 M 4,5 IE2 5,5 132 S 6,6 IE2 7,5 132 S 9 IE2 11 160 M 13,2 IE2 15 160 M 18 IE2 18,5 160 L 22 IE2 22 180 M 26 IE2 30 200 L 36 IE2 37 200 L 44 IE2 45 225 M 54 IE2 55 250 M 66 IE2 75 280 S 90 IE2 90 280 M 110 IE2 110 315 S 125 IE2 132 315 M 145 IE2 160 315 M 180 IE2 200 315 L 220 IE2 250 315 L 270 IE2 315 355 L 315 IE2 Motor type Article No. ANGK-090LR-02 ANGK-090LS-02 ANGK-100LS-02 ANGK-112MS-02 ANGK-132SR-02 ANGK-132SS-02 ANGK-160MR-02 ANGK-160MS-02 ANGK-160LS-02 ANGK-180MS-02 ANGK-200LR-02 ANGK-200LS-02 ANGK-225MS-02 ANGK-250MM-02 ANGK-280SL-02 ANGK-280MM-02 ANGK-315SL-02 ANGK-315ML-02 ANGK-315MN-02 ANGK-315LL-02 ANGK-315LN-02 ANGK-355LB-02 1PS10951PS10981PS11061PS11131PS11311PS11321PS11631PS11651PS11661PS11831PS12061PS12081PS12231PS12531PS12801PS12831PS13111PS13131PS13151PS13161PS13181PS1356- Price for 1 unit for IM B3 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA3 -3AA2 1.900,– 2.140,– 2.260,– 2.490,– 2.830,– 3.230,– 3.790,– 4.510,– 4.830,– 5.270,– 6.510,– 7.660,– 8.900,– 10.300,– 13.800,– 15.800,– 19.100,– 22.100,– 26.400,– 31.900,– 39.300,– 49.800,– LOHER VARIO 355 355 L 400 355 L 450 355 L 450 400 L 500 400 L 560 400 L 630 400 L 630 450 L 710 450 L 800 450 L 900 450 L 1000 500 L 1200 500 L 400 450 500 500 560 630 710 800 900 a.A. a.A. a.A. a.A. IE2 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) ANSK-355LC-02 ANSK-355LD-02 ANSK-355LX-02 ANSK-400LL-02 ANSK-400LN-02 ANSK-400LN-02 ANSK-400LX-02 ANSK-450LL-02 ANSK-450LL-02 ANSK-450LN-02 ANSK-450LN-02 ANSK-500LL-02 ANSK-500LN-02 1PS13571PS13581PS13581PS14041PS14051PS14071PS14081PS14531PS14551PS14571PS14581PS15071PS1508- Operating modes Frame size Mains-fed operation 90 ... 450 (<=800kW) Converter-fed operation, standard insulation 2) 90 ... 400 Converter-fed operation with special insulation 160 ... 500 (derating approx. 5 %) 2) Mains-fed operation, pre-formed coil 450 (>800kW) ... 500 Converter-fed operation, pre-formed coil 450 ... 500 Voltages 690 VD , 50Hz 355 ... 500 230 V/400 V, 50 Hz 90 ... 112 500 VY, 50 Hz 90 ... 315 500 VD , 50 Hz 355 ... 450 400 V/690 V, 50 Hz 90 ... 400 690 VY, 50 Hz 90 ... 400 For other voltages see options list 90 ... 500 Types of construction IM B3 90 ... 500 IM B5 90 ... 315 IM B34 90 ... 112 IM B14 90 ... 112 IM V1/canopy 90 ... 400 IM B35 90 ... 500 IM V1, without canopy 90 … 355 For other types of construction see options list 90 ... 500 1) Outside the IE code classification according to IEC60034-30. 2) BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ Order code - 3 4 … 0 1 2 3 4 6 8 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 49 47.700,– 50.000,– 58.400,– 60.400,– 65.700,– 73.600,– 78.600,– 86.400,– 89.500,– 94.800,– 108.000,– 135.000,– 151.000,– 0 1 2 0 1 3 5 6 8 9 Can only be ordered with additional identification code -Z and order code M73. -3AA0 -3AA0 -3AA0 -3AA0 -3AA0 -3AA0 -3AA0 -3AA0 -3AA0 -3AA0 -3AA0 -3AA0 -3AA0 … Discount level C Price for 1 unit for IM B3, 50Hz, mains operation Options acc. surcharge price list 1PS1… Frame size Discount level A Prated 50Hz LOHER CHEMSTAR and VARIO 1PS1 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE2, 0,75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Non-sparking" in accordance with EN 60079-15; 2010: CE 0102 II 3G Ex nA IIC T3 Gc Prated 60Hz kW FS kW IE class 4-pole: 1500 rpm at 50Hz LOHER CHEMSTAR 1,1 90 L 1,3 IE2 1,5 90 L 1,8 IE2 2,2 100 L 2,6 IE2 3 100 L 3,6 IE2 4 112 M 4,8 IE2 5,5 132 S 6,6 IE2 7,5 132 M 9 IE2 11 160 M 13 IE2 15 160 L 18 IE2 18,5 180 M 22 IE2 22 180 L 26 IE2 30 200 L 36 IE2 37 225 S 44 IE2 45 225 M 54 IE2 55 250 M 66 IE2 75 280 S 90 IE2 90 280 M 110 IE2 110 315 S 125 IE2 132 315 M 145 IE2 160 315 M 180 IE2 200 315 L 220 IE2 250 315 L 270 IE2 315 355 L 315 IE2 315 355 L 315 IE2 Motor type Article No. ANGK-090LR-04 ANGK-090LS-04 ANGK-100LR-04 ANGK-100LS-04 ANGK-112MS-04 ANGK-132SR-04 ANGK-132MS-04 ANGK-160MR-04 ANGK-160LS-04 ANGK-180MR-04 ANGK-180LS-04 ANGK-200LS-04 ANGK-225SR-04 ANGK-225MS-04 ANGK-250MM-04 ANGK-280SL-04 ANGK-280MM-04 ANGK-315SL-04 ANGK-315ML-04 ANGK-315MN-04 ANGK-315LL-04 ANGK-315LM-04 ANGK-355LB-04 2) ANGK-355LB-04 1PS10951PS10981PS11061PS11081PS11131PS11311PS11331PS11631PS11661PS11831PS11861PS12061PS12201PS12231PS12531PS12801PS12831PS13111PS13131PS13151PS13161PS13171PS13561PS1356- Price for 1 unit for IM B3 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA3 -3BA2 -3BB2 1.720,– 1.840,– 2.070,– 2.190,– 2.420,– 2.740,– 3.130,– 3.670,– 4.370,– 4.680,– 5.100,– 6.270,– 7.420,– 8.590,– 9.960,– 13.300,– 15.200,– 18.400,– 21.200,– 25.300,– 30.500,– 37.400,– 47.100,– 51.300,– Discount level A Frame size LOHER VARIO 355 355 L 400 355 L 450 355 L 500 355 L 500 400 L 560 400 L 630 400 L 710 400 L 800 450 L 900 450 L 950 450 L 1000 500 L 1120 500 L 1250 500 L 1400 500 L 400 IE2 1) 450 1) 500 1) 560 1) 560 1) 630 1) 710 1) 800 1) 900 1) 1000 1) a.A. 1) a.A. 1) a.A. 1) a.A. 1) a.A. ANSK-355LC-04 ANSK-355LD-04 ANSK-355LN-04 ANSK-355LX-04 ANSK-400LL-04 ANSK-400LN-04 ANSK-400LN-04 ANSK-400LX-04 ANSK-450LL-04 ANSK-450LN-04 ANSK-450LN-04 ANSK-500LL-04 ANSK-500LL-04 ANSK-500LN-04 ANSK-500LN-04 1PS13581PS13501PS13571PS13581PS14041PS14051PS14071PS14081PS14551PS14571PS14581PS15041PS15051PS15071PS1508- Operating modes Frame size Mains-fed operation 90 ... 450 (<=800kW) 3) Converter-fed operation, standard insulation 90 ... 400 Converter-fed operation with special insulation 160 ... 500 3) (derating approx. 5 %) Mains-fed operation, pre-formed coil 450 (>800kW) ... 500 Converter-fed operation, pre-formed coil 450 ... 500 Voltages 355 ... 500 690 VD , 50Hz 230 V/400 V, 50 Hz 90 ... 112 90 ... 315 500 VY, 50 Hz 500 VD , 50 Hz 355 ... 450 400 V/690 V, 50 Hz 90 ... 400 90 ... 400 690 VY, 50 Hz For other voltages see options list 90 ... 500 Types of construction IM B3 90 ... 500 IM B5 90 ... 315 90 ... 112 IM B34 IM B14 90 ... 112 90 ... 400 IM V1/canopy IM B35 90 ... 500 IM V1, without canopy 90 … 355 For other types of construction see options list 90 ... 500 1) Outside the IE code classification according to IEC60034-30. 2) Motor with special rotor (Cu). 3) Can only be ordered with additional identification code -Z and order code M73. BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ Order code - 3 4 … 0 1 2 3 4 6 8 9 50 45.900,– 48.700,– 56.100,– 58.600,– 64.800,– 69.200,– 75.900,– 81.900,– 87.500,– 99.800,– 109.000,– 117.000,– 123.000,– 135.000,– 138.000,– 0 1 2 0 1 3 5 6 8 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. -3BA0 -3BA0 -3BA0 -3BA0 -3BA0 -3BA0 -3BA0 -3BA0 -3BA0 -3BA0 -3BA0 -3BA0 -3BA0 -3BA0 -3BA0 … Discount level C Price for 1 unit for IM B3, 50Hz, mains operation Options acc. surcharge price list 1PS1… Prated 50Hz LOHER CHEMSTAR and VARIO 1PS1 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE2, 0,75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Non-sparking" in accordance with EN 60079-15; 2010: CE 0102 II 3G Ex nA IIC T3 Gc Prated 60Hz kW FS kW IE class 6-pole: 1000 rpm at 50Hz LOHER CHEMSTAR 0,75 90 L 0,75 IE2 1,1 90 L 0,9 IE2 1,5 100 L 1,25 IE2 2,2 112 M 1,8 IE2 3 132 S 3 IE2 4 132 M 4 IE2 5,5 132 M 5,5 IE2 7,5 160 M 7,5 IE2 11 160 L 11 IE2 15 180 L 15 IE2 18,5 200 L 18,5 IE2 22 200 L 22 IE2 30 225 M 30 IE2 37 250 M 37 IE2 45 280 S 45 IE2 55 280 M 55 IE2 75 315 S 75 IE2 90 315 M 90 IE2 110 315 M 110 IE2 132 315 M 132 IE2 160 315 L 160 IE2 200 315 L 200 IE2 200 315 L a.A. IE2 250 355 L 250 IE2 Motor type Article No. ANGK-090LR-06 ANGK-090LS-06 ANGK-100LS-06 ANGK-112MS-06 ANGK-132SR-06 ANGK-132MR-06 ANGK-132MS-06 ANGK-160MR-06 ANGK-160LS-06 ANGK-180LS-06 ANGK-200LR-06 ANGK-200LS-06 ANGK-225MS-06 ANGK-250MM-06 ANGK-280SL-06 ANGK-280MM-06 ANGK-315SL-06 ANGK-315ML-06 ANGK-315MM-06 ANGK-315MN-06 ANGK-315LL-06 ANGK-315LM-06 ANGK-315LM-06 2) ANGK-355LB-06 1PS10951PS10981PS11061PS11131PS11311PS11331PS11351PS11631PS11661PS11861PS12061PS12081PS12231PS12531PS12801PS12831PS13111PS13131PS13141PS13151PS13161PS13171PS13171PS1356- Price for 1 unit for IM B3 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CA3 -3CB3 -3CB2 1.820,– 1.960,– 2.280,– 2.900,– 3.300,– 3.790,– 4.010,– 4.170,– 4.700,– 5.700,– 6.120,– 6.630,– 8.810,– 10.300,– 13.500,– 15.300,– 18.900,– 21.400,– 23.700,– 26.100,– 31.400,– 38.600,– 44.200,– 48.500,– Discount level A Frame size LOHER VARIO 280 355 L 315 355 L 355 355 L 400 355 L 400 400 L 450 400 L 500 400 L 560 450 L 630 450 L 710 450 L 800 450 L 900 500 L 1000 500 L 1120 500 L 315 355 400 450 450 500 560 630 710 800 900 1000 1120 1250 IE2 IE2 IE2 ANSK-355LC-06 ANSK-355LD-06 ANSK-355LN-06 ANSK-355LN-06 ANSK-400LL-06 ANSK-400LN-06 ANSK-400LN-06 ANSK-450LL-06 ANSK-450LL-06 ANSK-450LN-06 ANSK-450LN-06 ANSK-500LL-06 ANSK-500LN-06 ANSK-500LN-06 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) Operating modes Mains-fed operation Converter-fed operation, standard insulation 3) Converter-fed operation with special insulation 1PS13571PS13581PS13571PS13581PS14041PS14051PS14071PS14531PS14551PS14571PS14581PS15051PS15071PS1508- Frame size 90 ... 450 90 ... 450 160 ... 500 (derating approx. 5 %) 3) Mains-fed operation, pre-formed coil 500 Converter-fed operation, pre-formed coil 450 ... 500 Voltages 690 VD , 50Hz 355 ... 500 230 V/400 V, 50 Hz 90 ... 112 500 VY, 50 Hz 90 ... 315 500 VD , 50 Hz 355 ... 450 400 V/690 V, 50 Hz 90 ... 400 690 VY, 50 Hz 90 ... 400 For other voltages see options list 90 ... 500 Types of construction IM B3 90 ... 500 IM B5 90 ... 315 IM B34 90 ... 112 IM B14 90 ... 112 IM V1/canopy 90 ... 450 IM B35 90 ... 500 IM V1, without canopy 90 … 355 For other types of construction see options list 90 ... 500 1) Outside the IE code classification according to IEC60034-30. 2) Motor with special rotor (Cu). 3) Can only be ordered with additional identification code -Z and order code M73. BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ Order code - 3 4 … 0 1 2 3 4 6 8 9 51 47.200,– 53.400,– 57.900,– 61.000,– 67.300,– 71.300,– 78.300,– 84.400,– 90.300,– 98.700,– 111.000,– 123.000,– 135.000,– 142.000,– 0 1 2 0 1 3 5 6 8 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. -3CA0 -3CA0 -3CA0 -3CA0 -3CA0 -3CA0 -3CA0 -3CA0 -3CA0 -3CA0 -3CA0 -3CA0 -3CA0 -3CA0 … Discount level C Price for 1 unit for IM B3, 50Hz, mains operation Options acc. surcharge price list 1PS1… Prated 50Hz LOHER CHEMSTAR and VARIO 1PS1 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Non-sparking" in accordance with EN 60079-15; 2010: CE 0102 II 3G Ex nA IIC T3 Gc Prated 60Hz kW FS kW IE class 8-pole: 750 rpm at 50Hz LOHER CHEMSTAR 1) 0,37 90 L a.A. 1) 0,55 90 L a.A. 1) 0,75 100 L a.A. 1) 1,1 100 L a.A. 1) 1,5 112 M a.A. 1) 2,2 132 S a.A. 1) 3 132 M a.A. 1) 4 160 M a.A. 1) 5,5 160 M a.A. 1) 7,5 160 L a.A. 1) 11 180 L a.A. 1) 15 200 L a.A. 1) 18,5 225 S a.A. 1) 22 225 M a.A. 1) 30 250 M a.A. 1) 37 280 S a.A. 1) 45 280 M a.A. 1) 55 315 S a.A. 1) 75 315 M a.A. 1) 90 315 M a.A. 1) 110 315 M a.A. 1) 132 315 L a.A. 1) 160 315 L a.A. 1) 200 355 L a.A. Motor type Article No. ANGK-090LR-08 ANGK-090LS-08 ANGK-100LR-08 ANGK-100LS-08 ANGK-112MS-08 ANGK-132SR-08 ANGK-132MR-08 ANGK-160MR-08 ANGK-160MS-08 ANGK-160LS-08 ANGK-180LS-08 ANGK-200LS-08 ANGK-225SR-08 ANGK-225MS-08 ANGK-250MM-08 ANGK-280SL-08 ANGK-280MM-08 ANGK-315SL-08 ANGK-315ML-08 ANGK-315MM-08 ANGK-315MN-082) ANGK-315LL-08 ANGK-315LM-083) ANGK-355LB-083) 1PS10951PS10981PS11061PS11081PS11131PS11311PS11331PS11631PS11651PS11661PS11861PS12061PS12201PS12231PS12531PS12801PS12831PS13111PS13131PS13141PS13151PS13161PS13171PS1356- Price for 1 unit for IM B3 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DA3 -3DB3 -3DB0 1.850,– 2.030,– 2.300,– 2.650,– 3.080,– 3.570,– 4.110,– 4.900,– 5.440,– 5.480,– 5.960,– 7.220,– 8.210,– 9.110,– 10.500,– 13.500,– 15.700,– 18.500,– 21.800,– 25.800,– 31.400,– 38.900,– 49.000,– 59.300,– Discount level A Frame size LOHER VARIO 225 355 L 250 355 L 280 355 L 315 355 L 355 400 L 400 400 L 450 400 L 500 450 L 560 450 L 630 450 L 670 450 L 710 500 L 800 500 L 900 500 L 950 500 L 250 280 315 355 400 450 500 560 630 710 750 800 900 1000 1050 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) ANSK-355LC-08 ANSK-355LD-08 ANSK-355LN-08 ANSK-355LX-08 ANSK-400LL-08 ANSK-400LN-08 ANSK-400LX-08 ANSK-450LL-08 ANSK-450LN-08 ANSK-450LN-08 ANSK-450LX-08 ANSK-500LL-08 ANSK-500LL-08 ANSK-500LN-08 ANSK-500LX-08 1PS13571PS13581PS13571PS13581PS14041PS14071PS14081PS14551PS14571PS14581PS14501PS15041PS15051PS15071PS1508- Operating modes Frame size Mains-fed operation 90 ... 450 4) Converter-fed operation, standard insulation 90 ... 450 Converter-fed operation with special insulation 160 ... 500 (derating approx. 5 %) 4) Mains-fed operation, pre-formed coil 500 Converter-fed operation, pre-formed coil 500 Voltages 690 VD , 50Hz 355 ... 500 230 V/400 V, 50 Hz 90 ... 112 500 VY, 50 Hz 90 ... 315 500 VD , 50 Hz 355 ... 450 400 V/690 V, 50 Hz 90 ... 400 690 VY, 50 Hz 90 ... 400 90 ... 500 For other voltages see options list Types of construction IM B3 90 ... 500 IM B5 90 ... 315 IM B34 90 ... 112 IM B14 90 ... 112 90 ... 450 IM V1/canopy IM B35 90 ... 500 IM V1, without canopy 90 … 355 For other types of construction see options list 90 ... 500 1) Outside the IE code classification according to IEC60034-30. 2) Rated output, partial utilization up to 155°C (F). 3) Motor with special rotor (Cu). 4) Can only be ordered with additional identification code -Z and order code M73. BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ Order code - 3 4 … 0 1 2 3 4 6 8 9 52 48.700,– 51.800,– 61.500,– 67.700,– 73.500,– 80.600,– 86.900,– 93.000,– 99.000,– 104.000,– 110.000,– 126.000,– 133.000,– 144.000,– 149.000,– 0 1 2 0 1 3 5 6 8 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. -3DA0 -3DA0 -3DA0 -3DA0 -3DA0 -3DA0 -3DA0 -3DA0 -3DA0 -3DA0 -3DA0 -3DA0 -3DA0 -3DA0 -3DA0 … Discount level C Price for 1 unit for IM B3, 50Hz, mains operation Options acc. surcharge price list 1PS1… Prated 50Hz LOHER CHEMSTAR and VARIO 1PS1 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Non-sparking" in accordance with EN 60079-15; 2010: CE 0102 II 3G Ex nA IIC T3 Gc Prated 50Hz Frame size Prated 60Hz kW FS kW IE class Motor type Article No. ANSK-355LC-10 ANSK-355LD-10 ANSK-355LX-10 ANSK-400LL-10 ANSK-400LN-10 ANSK-400LN-10 ANSK-400LX-10 ANSK-450LL-10 ANSK-450LN-10 ANSK-450LN-10 ANSK-450LX-10 ANSK-500LL-10 ANSK-500LN-10 ANSK-500LN-10 ANSK-500LX-10 1PS13571PS13581PS13581PS14041PS14051PS14071PS14081PS14541PS14551PS14571PS14581PS15041PS15051PS15071PS1508- ANSK-355LC-12 ANSK-355LD-12 ANSK-355LX-12 ANSK-400LL-12 ANSK-400LN-12 ANSK-400LN-12 ANSK-400LX-12 ANSK-450LL-12 ANSK-450LN-12 ANSK-450LN-12 ANSK-450LX-12 ANSK-500LL-12 ANSK-500LN-12 ANSK-500LN-12 ANSK-500LX-12 1PS13571PS13581PS13581PS14041PS14051PS14071PS14081PS14541PS14551PS14571PS14581PS15041PS15051PS15071PS1508- Price for 1 unit for IM B3, 50Hz, mains operation LOHER VARIO 160 355 L 180 355 L 190 355 L 200 400 L 225 400 L 250 400 L 280 400 L 315 450 L 355 450 L 400 450 L 420 450 L 450 500 L 500 500 L 560 500 L 600 500 L 180 200 215 225 250 280 315 355 400 450 475 500 560 630 650 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) Operating modes Frame size Mains-fed operation 355 ... 400 2) Converter-fed operation, standard insulation 355 ... 400 Converter-fed operation with special insulation 355 ... 500 (derating approx. 5 %) 2) Mains-fed operation, pre-formed coil 450 ... 500 Converter-fed operation, pre-formed coil 450 ... 500 Voltages 355 ... 500 690 VD , 50Hz 500 VY, 50 Hz 355 ... 500 500 VD , 50 Hz 355 ... 450 400 V/690 V, 50 Hz 355 ... 500 690 VY, 50 Hz 355 ... 500 For other voltages see options list 355 ... 500 Types of construction IM B3 355 ... 500 IM V1/canopy 355 ... 450 IM B35 355 ... 500 For other types of construction see options list 355 ... 500 1) Outside the IE code classification according to IEC60034-30. 2) BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ 53 -3FA0 -3FA0 -3FA0 -3FA0 -3FA0 -3FA0 -3FA0 -3FA0 -3FA0 -3FA0 -3FA0 -3FA0 -3FA0 -3FA0 -3FA0 51.800,– 55.000,– 65.300,– 72.000,– 78.200,– 85.800,– 92.300,– 98.700,– 105.000,– 109.000,– 118.000,– 133.000,– 141.000,– 148.000,– 156.000,– Order code - 3 4 … 0 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 50.200,– 53.400,– 63.400,– 69.800,– 75.800,– 83.200,– 89.500,– 95.900,– 102.000,– 107.000,– 114.000,– 131.000,– 137.000,– 148.000,– 154.000,– 0 1 2 0 3 5 6 8 9 Can only be ordered with additional identification code -Z and order code M73. -3EA0 -3EA0 -3EA0 -3EA0 -3EA0 -3EA0 -3EA0 -3EA0 -3EA0 -3EA0 -3EA0 -3EA0 -3EA0 -3EA0 -3EA0 … Discount level C Discount level C LOHER VARIO 1) 180 355 L 200 1) 200 355 L 225 1) 225 355 L 250 1) 250 400 L 280 1) 280 400 L 315 1) 315 400 L 355 1) 355 400 L 400 1) 400 450 L 450 1) 450 450 L 500 1) 500 450 L 560 1) 520 450 L 585 1) 560 500 L 630 1) 630 500 L 710 1) 670 500 L 750 1) 750 500 L 800 12-pole: 500 rpm at 50Hz LOHER CHEMSTAR on request Options acc. surcharge price list 1PS1… 10-pole: 600 rpm at 50Hz LOHER CHEMSTAR on request LOHER CHEMSTAR and VARIO 1PS1 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Non-sparking" in accordance with EN 60079-15; 2010: CE 0102 II 3G Ex nA IIC T3 Gc Prated 50Hz Frame size Prated 60Hz kW FS kW Motor type Article No. ANSK-355LC-14 ANSK-355LD-14 ANSK-400LL-14 ANSK-400LN-14 ANSK-400LN-14 ANSK-400LX-14 ANSK-450LL-14 ANSK-450LN-14 ANSK-450LN-14 ANSK-450LX-14 ANSK-500LL-14 ANSK-500LN-14 ANSK-500LN-14 ANSK-500LX-14 1PS13571PS13581PS14041PS14051PS14071PS14081PS14541PS14551PS14571PS14581PS15041PS15051PS15071PS1508- ANSK-355LC-16 ANSK-355LD-16 ANSK-400LL-16 ANSK-400LN-16 ANSK-400LX-16 ANSK-450LL-16 ANSK-450LN-16 ANSK-450LN-16 ANSK-450LX-16 ANSK-500LL-16 ANSK-500LN-16 ANSK-500LN-16 ANSK-500LX-16 1PS13571PS13581PS14051PS14071PS14081PS14541PS14551PS14571PS14581PS15041PS15051PS15071PS1508- Price for 1 unit for IM B3, 50Hz, mains operation LOHER VARIO 100 355 L 110 355 L 132 400 L 160 400 L 180 400 L 200 450 L 225 450 L 250 450 L 265 450 L 280 500 L 315 500 L 355 500 L 400 500 L 115 132 160 180 200 225 250 280 300 315 355 400 450 Operating modes Frame size Mains-fed operation 355 ... 500 1) Converter-fed operation, standard insulation 355 ... 500 Converter-fed operation with special insulation 355 ... 500 (derating approx. 5 %) 1) Mains-fed operation, pre-formed coil 450 ... 500 Converter-fed operation, pre-formed coil 450 ... 500 Voltages 355 ... 500 690 VD , 50Hz 500 VY, 50 Hz 355 ... 500 500 VD , 50 Hz 355 ... 450 400 V/690 V, 50 Hz 355 ... 500 690 VY, 50 Hz 355 ... 500 For other voltages see options list 355 ... 500 Types of construction IM B3 355 ... 500 IM V1/canopy 355 ... 500 IM B35 355 ... 500 For other types of construction see options list 355 ... 500 1) Can only be ordered with additional identification code -Z and order code M73. BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ -3HA0 -3HA0 -3HA0 -3HA0 -3HA0 -3HA0 -3HA0 -3HA0 -3HA0 -3HA0 -3HA0 -3HA0 -3HA0 56.800,– 64.600,– 80.500,– 88.500,– 95.100,– 102.000,– 108.000,– 112.000,– 121.000,– 138.000,– 146.000,– 157.000,– 164.000,– Order code - 3 4 … 0 4 6 9 54 51.800,– 55.000,– 72.000,– 78.200,– 85.800,– 92.300,– 98.700,– 105.000,– 110.000,– 118.000,– 135.000,– 141.000,– 152.000,– 159.000,– 0 1 2 0 3 5 6 8 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. -3GA0 -3GA0 -3GA0 -3GA0 -3GA0 -3GA0 -3GA0 -3GA0 -3GA0 -3GA0 -3GA0 -3GA0 -3GA0 -3GA0 … Discount level C Discount level C LOHER VARIO 125 355 L 140 140 355 L 160 160 400 L 180 180 400 L 200 200 400 L 225 225 400 L 250 250 450 L 280 280 450 L 315 315 450 L 355 340 450 L 380 355 500 L 400 400 500 L 450 450 500 L 500 500 500 L 560 16-pole: 375 rpm at 50Hz LOHER CHEMSTAR on request Options acc. surcharge price list 1PS1… 14-pole: 430 rpm at 50Hz LOHER CHEMSTAR on request LOHER CHEMSTAR 1PS1 motor series IE3 Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE3, 0,75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Non-sparking" in accordance with EN 60079-15; 2010: CE 0102 II 3G Ex nA IIC T3 Gc Prated 50Hz Frame Prated 60Hz size kW FS IE class Motor type Article No. ANGK-090LS-02 ANGK-090LT-02 ANGK-100LT-02 ANGK-112MT-02 ANGK-132SS-02 ANGK-132ST-02 ANGK-160MS-02 ANGK-160MT-02 ANGK-160LT-02 ANGK-180MT-02 ANGK-200LS-02 ANGK-200LT-02 ANGK-225MT-02 ANGK-250MN-02 ANGK-280SM-02 ANGK-280MN-02 ANGK-315SL-02 ANGK-315ML-02 ANGK-315MN-02 ANGK-315LL-02 ANGK-315LN-02 1PS10951PS10981PS11061PS11131PS11311PS11321PS11631PS11651PS11661PS11831PS12061PS12081PS12231PS12531PS12801PS12831PS13111PS13131PS13151PS13161PS1318- Price for 1 unit for IM B3 Operating modes Frame size Mains-fed operation 90 ... 315 Converter-fed operation, standard insulation 1) 90 ... 315 Voltages 90 ... 315 690 VD , 50Hz 230 V/400 V, 50 Hz 90 ... 280 500 VY, 50 Hz 90 ... 315 500 VD , 50 Hz 90 ... 315 400 V/690 V, 50 Hz 90 ... 315 690 VY, 50 Hz 90 ... 315 For other voltages see options list 90 ... 315 Types of construction IM B3 90 ... 315 IM B5 90 ... 315 IM B34 90 ... 112 IM B14 90 ... 112 90 ... 315 IM V1/canopy IM B35 90 ... 315 IM V1, without canopy 90 ... 315 For other types of construction see options list 90 ... 315 1) Can only be ordered with additional identification code -Z and order code M73. Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 55 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 -3AH3 2.210,– 2.450,– 2.630,– 2.900,– 3.330,– 3.730,– 4.490,– 5.210,– 5.530,– 6.080,– 7.450,– 8.600,– 9.950,– 11.400,– 15.100,– 17.100,– 20.500,– 23.500,– 27.800,– 33.300,– 40.700,– Order code - 0 1 … 0 1 3 5 6 8 9 0 1 2 3 4 6 8 9 … Options acc. surcharge price list 1PS1… Discount level A kW 2-pole: 3000 rpm at 50Hz LOHER CHEMSTAR 1,5 90 L 1,5 IE3 2,2 90 L 2,2 IE3 3 100 L 3 IE3 4 112 M 4 IE3 5,5 132 S 5,5 IE3 7,5 132 S 7,5 IE3 11 160 M 11 IE3 15 160 M 15 IE3 18,5 160 L 18,5 IE3 22 180 M 22 IE3 30 200 L 30 IE3 37 200 L 37 IE3 45 225 M 45 IE3 55 250 M 55 IE3 75 280 S 75 IE3 90 280 M 90 IE3 110 315 S 110 IE3 132 315 M 132 IE3 160 315 M 160 IE3 200 315 L 200 IE3 250 315 L 250 IE3 LOHER CHEMSTAR 1PS1 motor series IE3 Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE3, 0,75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Non-sparking" in accordance with EN 60079-15; 2010: CE 0102 II 3G Ex nA IIC T3 Gc Prated 50Hz Frame Prated 60Hz size kW FS IE class Motor type Article No. ANGK-090LS-04 ANGK-090LT-04 ANGK-100LS-04 ANGK-100LT-04 ANGK-112MT-04 ANGK-132ST-04 ANGK-132MT-04 ANGK-160MS-04 ANGK-160LT-04 ANGK-180MS-04 ANGK-180LT-04 ANGK-200LT-04 ANGK-225SS-04 ANGK-225MT-04 ANGK-250MN-04 ANGK-280SM-04 ANGK-280MN-04 ANGK-315SL-04 ANGK-315ML-04 ANGK-315MN-04 ANGK-315LL-04 ANGK-315LM-04 1PS10951PS10981PS11061PS11081PS11131PS11311PS11331PS11631PS11661PS11831PS11861PS12061PS12201PS12231PS12531PS12801PS12831PS13111PS13131PS13151PS13161PS1317- Price for 1 unit for IM B3 Operating modes Frame size Mains-fed operation 90 ... 315 Converter-fed operation, standard insulation 1) 90 ... 315 Voltages 90 ... 315 690 VD , 50Hz 230 V/400 V, 50 Hz 90 ... 280 500 VY, 50 Hz 90 ... 315 500 VD , 50 Hz 90 ... 315 400 V/690 V, 50 Hz 90 ... 315 690 VY, 50 Hz 90 ... 315 For other voltages see options list 90 ... 315 Types of construction IM B3 90 ... 315 IM B5 90 ... 315 IM B34 90 ... 112 IM B14 90 ... 112 90 ... 315 IM V1/canopy IM B35 90 ... 315 IM V1, without canopy 90 ... 315 For other types of construction see options list 90 ... 315 1) Can only be ordered with additional identification code -Z and order code M73. Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 56 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 -3BH3 2.030,– 2.150,– 2.440,– 2.560,– 2.830,– 3.240,– 3.630,– 4.370,– 5.070,– 5.490,– 5.910,– 7.210,– 8.470,– 9.640,– 11.100,– 14.600,– 16.500,– 19.800,– 22.600,– 26.700,– 31.900,– 38.800,– Order code - 0 1 … 0 1 3 5 6 8 9 0 1 2 3 4 6 8 9 … Options acc. surcharge price list 1PS1… Discount level A kW 4-pole: 1500 rpm at 50Hz LOHER CHEMSTAR 1,1 90 L 1,1 IE3 1,5 90 L 1,5 IE3 2,2 100 L 2,2 IE3 3 100 L 3 IE3 4 112 M 4 IE3 5,5 132 S 5,5 IE3 7,5 132 M 7,5 IE3 11 160 M 11 IE3 15 160 L 15 IE3 18,5 180 M 18,5 IE3 22 180 L 22 IE3 30 200 L 30 IE3 37 225 S 37 IE3 45 225 M 45 IE3 55 250 M 55 IE3 75 280 S 75 IE3 90 280 M 90 IE3 110 315 S 110 IE3 132 315 M 132 IE3 160 315 M 160 IE3 200 315 L 200 IE3 250 315 L 250 IE3 LOHER CHEMSTAR 1PS1 motor series IE3 Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE3, 0,75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % · Type of protection: "Non-sparking" in accordance with EN 60079-15; 2010: CE 0102 II 3G Ex nA IIC T3 Gc Prated 50Hz Frame Prated 60Hz size kW FS IE class Motor type Article No. ANGK-090LS-06 ANGK-100LS-06 ANGK-100LT-06 ANGK-112MT-06 ANGK-132SS-06 ANGK-132MS-06 ANGK-132MT-06 ANGK-160MS-06 ANGK-160LT-06 ANGK-180LT-06 ANGK-200LS-06 ANGK-200LT-06 ANGK-225MT-06 ANGK-250MN-06 ANGK-280SM-06 ANGK-280MN-06 ANGK-315SL-06 ANGK-315ML-06 ANGK-315MM-06 ANGK-315LK-06 ANGK-315LL-06 ANGK-315LM-06 1PS10951PS11051PS11061PS11131PS11311PS11331PS11351PS11631PS11661PS11861PS12061PS12081PS12231PS12531PS12801PS12831PS13111PS13131PS13141PS13151PS13161PS1317- Price for 1 unit for IM B3 Operating modes Frame size Mains-fed operation 90 ... 315 Converter-fed operation, standard insulation 1) 90 ... 315 Voltages 90 ... 315 690 VD , 50Hz 230 V/400 V, 50 Hz 90 ... 280 500 VY, 50 Hz 90 ... 315 500 VD , 50 Hz 90 ... 315 400 V/690 V, 50 Hz 90 ... 315 690 VY, 50 Hz 90 ... 315 For other voltages see options list 90 ... 315 Types of construction IM B3 90 ... 315 IM B5 90 ... 315 IM B34 90 ... 112 IM B14 90 ... 112 90 ... 315 IM V1/canopy IM B35 90 ... 315 IM V1, without canopy 90 ... 315 For other types of construction see options list 90 ... 315 1) Can only be ordered with additional identification code -Z and order code M73. Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 57 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 -3CH3 2.130,– 2.380,– 2.650,– 3.310,– 3.800,– 4.290,– 4.510,– 4.870,– 5.400,– 6.510,– 7.060,– 7.570,– 9.860,– 11.400,– 14.800,– 16.600,– 20.300,– 22.800,– 25.100,– 27.500,– 32.800,– 40.000,– Order code - 0 1 … 0 1 3 5 6 8 9 0 1 2 3 4 6 8 9 … Options acc. surcharge price list 1PS1… Discount level A kW 6-pole: 1000 rpm at 50Hz LOHER CHEMSTAR 0,75 90 L 0,75 IE3 1,1 100 L 1,1 IE3 1,5 100 L 1,5 IE3 2,2 112 M 2,2 IE3 3 132 S 3 IE3 4 132 M 4 IE3 5,5 132 M 5,5 IE3 7,5 160 M 7,5 IE3 11 160 L 11 IE3 15 180 L 15 IE3 18,5 200 L 18,5 IE3 22 200 L 22 IE3 30 225 M 30 IE3 37 250 M 37 IE3 45 280 S 45 IE3 55 280 M 55 IE3 75 315 S 75 IE3 90 315 M 90 IE3 110 315 M 110 IE3 132 315 L 132 IE3 160 315 L 160 IE3 200 315 L 200 IE3 LOHER CHEMSTAR and VARIO 1PS1 motor series Article No. supplements Selection and ordering data Voltages Voltage Additional Motor series code identification LOHER CHEMSTAR 11th position code with of the Article No. order code Discount level A and plain text if required 1PS1. . . - . . . LOHER VARIO Surcharge / List price EURO Discount level C Frame size .-.... 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Optional voltages 690 V D, 50Hz 0 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 230 V D / 400 V S, 50Hz 1 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N N N 500 V S, 50Hz 3 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N 400 V D, 50Hz 4 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 500 V D, 50Hz 5 87,– 107,– 130,– o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 400 V D / 690 V S, 50Hz 6 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 690 V S, 50Hz 415 V S, 50Hz 1) 8 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N 9 L1C 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 415 V D, 50Hz 1) 9 L1D 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– o.MP. o.MP. o.MP. o.MP. 380 V D / 660 V S, 50Hz 1) 9 L1L 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 220 V D / 380 V S, 50Hz 1) 9 L1R 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– N N N N N N 1000 V D, 50 Hz 1) Other voltages 1) 9 9 L1V L1Y ● and identification code 87,– 87,– 107,– 107,– 130,– 130,– 165,– 165,– 206,– 206,– 265,– 265,– 323,– 323,– 478,– 478,– 603,– 603,– 772,– 772,– 1.000,– 1.000,– 1.210,– 1.210,– N a.A. N a.A. N a.A. N a.A. 220 V D / 380 V S, 60Hz (50Hz-output) 1) 9 L2A 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– N N N N N N 220 V D / 380 V S, 60Hz (60Hz-output) 1) 9 L2B 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– N N N N N N 380 V D / 660 V S, 60Hz (50Hz-output) 1) 9 L2C 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– N N N N N N 380 V D / 660 V S, 60Hz (60Hz-output) 1) 9 L2D 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– N N N N N 460 V S, 60Hz (60Hz-output) 1) 9 L2E 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 460 V D, 60Hz (60Hz-output) 1) 9 L2F 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– 575 V S, 60Hz (60Hz-output) 1) 9 L2L 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N 575 V D, 60Hz (60Hz-output) 1) 9 L2M 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– 440 V S, 60Hz (50Hz-output) 1) 9 L2Q 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 440 V D, 60Hz (50Hz-output) 1) 9 L2R 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 460 V S, 60Hz (50Hz-output) 1) 9 L2S 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 460 V D, 60Hz (50Hz-output) 1) 9 L2T 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 575 V S, 60Hz (50Hz-output) 1) 9 L2U 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 575 V D, 60Hz (50Hz-output) 1) 9 L2V 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 440 V S, 60Hz (60Hz-output) 1) 9 L2W 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 440 V D, 60Hz (60Hz-output) 1) 9 9 L2X L2Y ● and identification code 43,– N 54,– N 65,– N 83,– N 102,– N 132,– N 152,– N 213,– N 243,– N 314,– N 408,– N 530,– N see PMD a.A. a.A. a.A. Other voltages 60Hz 1) 1) = Basis 1 - 4 pcs. / calculate factor 0.5 for 5 - 19 pcs. ! □ = Standard version o.MP. = Without surcharge - For motors for converter-fed operation, the converter rating plate is stamped with 380 V or 400 V. ● = This order code only determines the price of the version - additional plain text is required. - For motors with a Dahlander circuit, the lower voltage is generally specified. a.A. = On request Voltages not listed are only available on request. For dual voltages 230 V/400 V, 220 V/380 V, 400 V/690 V or 380 V/660 V: N = Not available Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 58 o.MP. see PMD N N see PMD a.A. LOHER CHEMSTAR and VARIO 1PS1 motor series Article No. supplements Selection and ordering data Types of construction Mounting Additional Motor series type code identification LOHER CHEMSTAR 12th position code with of the order code Article No. and plain text if required 1PS1. . . - . . . . LOHER VARIO Surcharge / List price EURO Discount level A Discount level C Frame size -.... 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Optional types of construction IM B3 IM B5 2) 0 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 1 95,– 117,– 146,– 199,– 266,– 431,– 508,– 637,– 809,– 1.010,– 1.330,– 1.750,– N N N N IM B34 2 118,– 146,– 189,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N IM B14 IM V1, with canopy - LOHER CHEMSTAR 3 95,– 117,– 146,– a.A. a.A. a.A. N N N N N N N N N N 4 168,– 199,– 243,– 321,– 433,– 699,– 856,– 1.070,– 1.340,– 1.650,– 2.190,– 3.160,– N N N N a.A. IM V1, with canopy - LOHER VARIO 50Hz 2-pole (11: 0,4,5,6; 14: A) 4 5.110,– 6.860,– 11.300,– IM V1, with canopy - LOHER VARIO 60Hz 2-pole (11: 9; 14: A) 4 6.810,– 9.150,– a.A. a.A. IM V1, with canopy - LOHER VARIO 4-pole (14: B) 4 3.410,– 4.580,– 5.630,– 11.400,– IM V1, with canopy - LOHER VARIO ab 6-pole (14: C,D,E,F,G,H) 4 IM B35 IM B6 2) 6 9 IM B7 2) 9 IM B8 2) IM V6 2) 3.410,– 4.580,– 5.630,– 7.580,– 118,– 146,– 189,– 305,– 467,– 546,– 637,– 809,– 1.090,– 1.410,– 1.860,– 2.980,– 3.410,– 4.580,– 5.630,– 7.580,– M1A o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. a.A. a.A. N N N N M1B o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. a.A. a.A. N N N N 9 M1C o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. a.A. a.A. N N N N 9 M1E o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. a.A. a.A. N N N N IM V5, with canopy 2) 9 M1F 80,– 84,– 102,– 131,– 171,– 275,– 362,– 454,– 568,– 683,– 909,– 1.410,– N N N N IM V3 9 M1G 94,– 117,– 146,– 199,– 266,– 431,– 508,– 637,– 809,– 1.010,– 1.330,– a.A. N N N N IM V15, with canopy 9 M2K 191,– 228,– 286,– 427,– 634,– 814,– 985,– 1.240,– 1.620,– 2.050,– 2.720,– a.A. N N N N IM V18, with canopy 9 M2M 168,– 199,– 243,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N Other types of construction and special flange diameters on request ! 2) LOHER CHEMSTAR at frame size 315 / 355 only for direct coupling without vibrations, others on request □ = Standard version o.MP. = Without surcharge ● = This order code only determines the price of the version - additional plain text is required. a.A. = On request N = Not available Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 59 LOHER CHEMSTAR and VARIO 1PS1 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code and plain text 1PS1. . . - . . . . . - . . . . -Z if required Discount level C Frame size 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Special electrical designs / winding protection Design with reduced starting current - factory clarification required and eventually type test needed, a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. ETO-Option (Engineer To Order) without order code Special design according load curve of driven equipment or customer requirements - factory clarification required and eventually type test needed, ETO-Option without order code Adjusting of rating according to customer requirements - factory clarification required and eventually type test needed, ETO-Option without order code Motor protection with 3 PTC thermistors for switching-off - without lightning arresters, sole protection not included A11 114,– 114,– 114,– 145,– 145,– 190,– 190,– 227,– 227,– 240,– 240,– 302,– 1.150,– 1.150,– 1.150,– 2.300,– Motor protection with 2 x 3 PTC thermistors for prewarning / switching-off - without lightning arresters, A12 194,– 194,– 194,– 247,– 247,– 279,– 279,– 333,– 333,– 352,– 352,– 392,– 1.730,– 1.730,– 1.730,– 3.460,– Motor protection with 3 PTC thermistors for switching-off as sole protection with inverter (TMS) A15 314,– 314,– 314,– 345,– 345,– 434,– 434,– 471,– 605,– 618,– 618,– 694,– 2.500,– 2.500,– 3.000,– 4.000,– Motor protection with 2 x 3 PTC thermistors for prewarning/switching-off as sole protection with inverter (TMS) A16 534,– 534,– 534,– 587,– 587,– 637,– 637,– 691,– 691,– 711,– 711,– 866,– 3.000,– 3.000,– 3.500,– 4.750,– Temperature measuring of the winding by means of embedded temperature sensor KTY84-130 A23 314,– 314,– 314,– 345,– 345,– 434,– 434,– 471,– 605,– 618,– 618,– 694,– 1.150,– 1.150,– 1.150,– 1.150,– Temperature measuring of the winding by means of embedded temperature sensors 2 x KTY84-130 A25 534,– 534,– 534,– 587,– 587,– 637,– 637,– 691,– 691,– 711,– 711,– 866,– 1.750,– 1.750,– 1.750,– 1.750,– Temperature monitoring of winding with 3 resistance thermometer PT100 - in 2-wire design A60 N N N N 999,– 999,– 999,– 999,– 999,– 999,– 999,– 999,– N N N N Temperature monitoring of winding with 2 x 3 resistance thermometer PT100 - 2-wire design, A61 N N N N a.A. a.A. a.A. a.A. a.A. 1.300,– 1.300,– 1.300,– 1.730,– 1.730,– 1.730,– 1.730,– 3 PT100 resistance thermometers in stator winding, 3-wire circuit from terminals of the auxiliary terminal box A63 N N N N N N N N N N N N 1.150,– 1.150,– 1.150,– 1.150,– 6 PT100 resistance thermometers in stator winding, 3-wire circuit from terminals of the auxiliary terminal box A64 N N N N N N N N N N N N 2.000,– 2.000,– 2.000,– 2.000,– 6 embedded resistance thermometers PT100 without lightning arresters for 4-wire connection from terminals A65 N N N N N N N N N N N N 1.730,– 1.730,– 1.730,– 1.730,– A66 N N N N N N N N N N N N 3.450,– 3.450,– 3.450,– 3.450,– A67 N N N N N N N N N N N N 3.450,– 3.450,– 3.450,– 3.450,– Q40 N N N N N N N N N N N N 4.320,– 4.320,– 4.320,– 4.320,– V80 N N N N N N N N N N N N 3.450,– 3.450,– 3.450,– 3.450,– Q43 N N N N N N N N N N N N 850,– 850,– 850,– 850,– Bearing RTD's-PT100 in 3- or 4-wire type ex sensor instead of ex terminal - optionally possible for V80, A40, A42 Q44 N N N N N N N N N N N N 576,– 576,– 576,– 576,– Inner air-PT100 in 3- or 4-wire type ex sensor instead of ex terminal Q45 N N N N N N N N N N N N a.A. a.A. a.A. a.A. One thermocouple per bearing Q49 N N N N N N N N N N N N 4.320,– 4.320,– 4.320,– 4.320,– Sensor for enclosure vibration monitoring (preferred product) with loose cable - per sensor V14 N N N N N N N N N N N N 1.700,– 1.700,– 1.700,– 1.700,– Sensor for enclosure vibration monitoring (preferred product), without junction box - per sensor V15 N N N N N N N N N N N N 2.880,– 2.880,– 2.880,– 2.880,– 3 Transmitter 4-20 mA for PT100 winding P20 N N N N N N N N N N N N 2.500,– 2.500,– 2.500,– 2.500,– One Transmitter with digital display with Exd or Exi-approval V88 N N N N N N N N N N N N 3.450,– 3.450,– 3.450,– 3.450,– PT100 winding in tolerance class A with calibration certificate sole protection not included round wire winding only - only at form coil winding 6 embedded resistance thermometers PT100 with lightning arresters for 4-wire connection from terminals - only at form coil winding 6 embedded resistance thermometers PT100 in shielded design without lightning arresters for 4-wire connection from terminals - only at form coil winding 6 Exi-slot resistance thermometers PT100 in shielded design with lightning arrestors for 3- and 4-wire connection from terminal - only at form coil winding 2 double RTD's PT100 in shielded design (Ex i) for antifriction or sleeve bearing - 2-wire elements with 4-wire connection ex terminal box Winding RTD's-PT100 in 3- or 4-wire type ex sensor instead ex terminal (not possible for Exi!) - optionally possible for A60, A61, A65, A66 V78 N N N N N N N N N N N N 2.850,– 2.850,– 2.850,– 2.850,– 2) D06 86,– 107,– 129,– 150,– 172,– 193,– 214,– 236,– 257,– 279,– 300,– 320,– 2.200,– 3.080,– 4.000,– 5.320,– 2) D07 124,– 156,– 187,– 218,– 249,– 280,– 311,– 342,– 373,– 404,– 435,– 464,– 2.200,– 3.080,– 4.000,– 5.320,– 2) D08 180,– 225,– 271,– 316,– 361,– 406,– 451,– 496,– 541,– 586,– 631,– 673,– 2.200,– 3.080,– 4.000,– 5.320,– 2) 5.320,– Site altitude max. 1500 m above sea level (observe derating) Site altitude max. 2000 m above sea level (observe derating) Site altitude max. 2500 m above sea level (observe derating) Site altitude max. 3000 m above sea level (observe derating) D09 307,– 383,– 460,– 536,– 613,– 690,– 766,– 843,– 919,– 996,– 1.070,– 1.140,– 2.200,– 3.080,– 4.000,– Cooling air temperature max. 45 °C (observe derating) 2) D11 86,– 107,– 129,– 150,– 172,– 193,– 214,– 236,– 257,– 279,– 300,– 320,– 2.200,– 3.080,– 4.000,– 5.320,– Cooling air temperature max. 50 °C (observe derating) 2) D12 124,– 156,– 187,– 218,– 249,– 280,– 311,– 342,– 373,– 404,– 435,– 464,– 2.200,– 3.080,– 4.000,– 5.320,– Cooling air temperature max. 55 °C (observe derating) 2) D13 180,– 225,– 271,– 316,– 361,– 406,– 451,– 496,– 541,– 586,– 631,– 673,– 2.200,– 3.080,– 4.000,– 5.320,– Cooling air temperature max. 60 °C (observe derating) 2) D14 307,– 383,– 460,– 536,– 613,– 690,– 766,– 843,– 919,– 996,– 1.070,– 1.140,– 2.200,– 3.080,– 4.000,– 5.320,– D15 86,– 107,– 129,– 150,– 172,– 193,– 214,– 236,– 257,– 279,– 300,– 320,– a.A. a.A. a.A. a.A. D16 124,– 156,– 187,– 218,– 249,– 280,– 311,– 342,– 373,– 404,– 435,– 464,– a.A. a.A. a.A. a.A. D17 180,– 225,– 271,– 316,– 361,– 406,– 451,– 496,– 541,– 586,– 631,– 673,– a.A. a.A. a.A. a.A. D18 87,– 107,– 130,– 165,– 206,– 265,– 323,– 478,– 603,– 772,– 1.000,– 1.300,– N N N N 2) Derating acc. to catalogue D 83.1; efficiency class of MLFB unchanged. No surcharge if special voltage is chosen ( MLFB digit 11=9) Cooling water temperature max. 30 °C (consider power reduction) - power reduction acc. to derating table. No surcharge if special voltage is chosen ( MLFB digit 11=9) Cooling water temperature max. 35 °C (consider power reduction) - power reduction acc. to derating table. No surcharge if special voltage is chosen ( MLFB digit 11=9) Cooling water temperature max. 40 °C (consider power reduction) - power reduction acc. to derating table. No surcharge if special voltage is chosen ( MLFB digit 11=9) Cooling temperature less than +40 °C with increased rating -factory clarification required, not applicable at IE2 No surcharge if special voltage is chosen ( MLFB digit 11=9) Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 60 LOHER CHEMSTAR and VARIO 1PS1 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code and plain text 1PS1. . . - . . . . . - . . . . -Z if required Discount level C Frame size 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Special electrical designs / winding protection Utilization acc. to insulation class 155(F) - if DOL duty rating according IEC standard maximal. C12 87,– 107,– 130,– 165,– 206,– 265,– 323,– 478,– 603,– 772,– 1.000,– 1.300,– N N N N C29 43,– 50,– 50,– 66,– 66,– 84,– 84,– 96,– 96,– 112,– 112,– 115,– N N N N No surcharge if special voltage is chosen (MLFB digit 11=9) Rated output of next smaller power in size - IEC rating steps will considered in combination with D06 to D18 No surcharge if special voltage is chosen ( MLFB digit 11=9) Moderately extended speed range at inverter operation V82 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Insulation class F W00 N N N N N N N N N N N N o.MP. o.MP. o.MP. o.MP. Insulation class H W01 535,– 575,– 677,– 677,– 1.030,– 1.100,– 1.210,– 1.350,– 1.660,– 2.040,– 2.400,– 2.550,– N N N N N N N N 2.070,– 2.210,– 2.420,– 2.690,– 3.310,– 4.090,– 4.780,– N 4.150,– 5.750,– 7.500,– 9.750,– 433,– 473,– 502,– 876,– 1.570,– 1.690,– 2.060,– 2.710,– 3.690,– 4.780,– 5.980,– 7.480,– a.A. a.A. a.A. a.A. 88,– N 88,– N 90,– N 106,– N 484,– N 564,– N 864,– N 1.170,– N 1.420,– N 2.100,– N 2.470,– N 2.900,– N N 1.440,– N 1.440,– N 1.440,– N 1.440,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. Reinforced winding isolation in case of inverter duty (Phase/Phase 2250V Peak / power reduction) at LOHER CHEMSTAR MLFB digit 8=2 Sealing of the winding head with silicone rubber W03 Sealing of the cable duct with silicone rubber Abnormal voltage and/or frequency for separate fan drive motor W04 Y81 ● and identification code Other electrical designs Colors and paint finish Inner corrosion protection Loher coating system J08 W10 210,– 234,– 260,– 292,– 331,– 374,– 422,– 476,– 536,– 603,– 679,– 764,– N N N N Coating system N08 - 110µm (C3-medium) - Corrosion category acc. to EN/ISO 12944-5 = C3 V09 89,– 103,– 119,– 139,– 161,– 188,– 217,– 249,– 285,– 325,– 370,– 422,– o.MP. o.MP. o.MP. o.MP. Coating system N14/J08 - 170µm (Chemical industry + On Shore, C5 - Industrial climate) - V10 358,– 406,– 460,– 523,– 600,– 686,– 782,– 890,– 1.010,– 1.150,– 1.300,– 1.470,– 1.440,– 1.440,– 1.440,– 1.440,– W14 148,– 172,– 199,– 231,– 269,– 313,– 361,– 415,– 475,– 542,– 617,– 703,– N N N N Special prime coat system Z05 with inner corrosion protection system J08 W15 419,– 467,– 521,– 584,– 661,– 747,– 843,– 951,– 1.170,– 1.550,– 2.010,– 2.410,– N N N N Coating system Z21/J08 - 210µm (Off Shore, C5M-M) - V11 716,– 812,– 919,– 1.050,– 1.200,– 1.370,– 1.570,– 1.780,– 2.120,– 2.630,– 3.240,– 3.810,– 3.500,– 3.500,– 3.500,– 3.500,– Corrosion category acc. to EN/ISO 12944-5 = C5 (5-15 years) for industrial climate Coating system N14A (Chemical + On Shore, C5 - Industry) Corrosion category acc. to EN/ISO 12944-5 = C5 (5-15 years) for industrial climate Corrosion category acc. to EN/ISO 12944-5 = C5 (5-15 years) - sea-climate Increased layer thickness 275µm for coating system Z21 (C5M-high) - only in combination with V11 - V19 148,– 172,– 199,– 231,– 269,– 313,– 361,– 415,– 475,– 542,– 617,– 703,– 1.440,– 1.440,– 1.440,– 1.440,– V12 1.090,– 1.180,– 1.380,– 1.510,– 1.760,– 1.930,– 2.120,– 2.340,– 2.770,– 3.280,– 3.980,– 4.740,– 8.500,– 8.500,– 8.500,– 9.000,– Corrosion category acc. to EN/ISO 12944-5 = C5 high (>15 years) - sea-climate Special offshore painting S13 related to NORSOK M501 ( C5M-high ) with comments and deviations Corrosion category acc. to EN/ISO 12944-5 = C5 high (>15 years) - sea-climate Special coating system S11/J08 (e. g. submerged motors) V13 478,– 507,– 556,– 658,– 1.080,– 1.190,– 1.460,– 1.680,– 2.040,– 2.960,– 3.760,– 5.400,– 5.500,– 5.500,– 5.500,– 5.500,– Without coating, but primed K24 29,– 29,– 29,– 46,– 46,– 86,– 86,– 86,– 86,– 86,– 86,– 98,– N N N N Without coating K23 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N Outer painting for zink galvanized noise cabinet N08 (110µm) V98 N N N N N N N N N N N N 3.600,– 3.900,– 4.200,– 4.500,– Paint Colours according Munsell or British Standard Y50 ● and N N N N N N N N N N N N 2.300,– 2.300,– 2.300,– 2.850,– 63,– 106,– 106,– 139,– 139,– 194,– 243,– 243,– 243,– 243,– 243,– 243,– 576,– 576,– 576,– 864,– 63,– 106,– 106,– 139,– 139,– 194,– 243,– 243,– 243,– 243,– 243,– 243,– 576,– 576,– 576,– 864,– 95,– 159,– 159,– 209,– 209,– 291,– 365,– 365,– 365,– 365,– 365,– 365,– 1.150,– 1.150,– 1.150,– 1.700,– 212,– 212,– 212,– 278,– 278,– 388,– 486,– 486,– 486,– 486,– 486,– 486,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. identification code Standard coating in RAL1004,1018,2000,2004,5009,5012,5015,6003,6011,7000,7011,7031,7038,9002 Y53 ● and standard coating RAL… Special coating in RAL1004,1018,2000,2004,5009,5012,5015,6003,6011,7000,7011,7031,7038,9002 - Y54 ● and special specify special coating system in addition, e.g. V10, V11, W14, etc. coating RAL… RAL colours different to above indicated Y51 ● and special coating RAL… Special colour not RAL Y71 ● and identification code Other painting combinations / systems or RAL colours to customer specification Design for Zones according to ATEX Design in Ex nA II - T3 (zone 2) IEC 60 079-15 for converter duty - system test with original inverter M73 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N Design for zone 21 (conductive dust) at inverter operation M38 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Design for zone 22 (non conductive dust) at inverter operation M39 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Design in double protection additionally for dust, Zone 22 at mains operation; no hybrid certification - W20 122,– 134,– 153,– 168,– 353,– 353,– 395,– 411,– 427,– 444,– 461,– 479,– a.A. a.A. a.A. a.A. W21 342,– 383,– 401,– 417,– 601,– 679,– 721,– 736,– 752,– 769,– 785,– 802,– a.A. a.A. a.A. a.A. W22 135,– 148,– 168,– 185,– 388,– 388,– 435,– 452,– 469,– 488,– 507,– 527,– a.A. a.A. a.A. a.A. W23 376,– 421,– 441,– 458,– 661,– 747,– 793,– 810,– 828,– 845,– 864,– 882,– a.A. a.A. a.A. a.A. non conductive dust Design in double protection additionally for dust, Zone 21 at mains operation; no hybrid certification design and certification for conductive dust (incl. non conductive dust) Design in double protection additionally for dust, Zone 22 at inverter operation; no hybrid certification non conductive dust; options for inverter operation choose separately Design in double protection additionally for dust, Zone 21 at inverter operation; no hybrid certification design and certification for conductive dust (incl. non conductive dust); options for inverter operation choose separately Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation Price List LOHER Motors 2015 Version a. 61 LOHER CHEMSTAR and VARIO 1PS1 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code and plain text 1PS1. . . - . . . . . - . . . . -Z if required Discount level C Frame size 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Ship design "Operation below deck" Design acc. to GL ( Germanischer Lloyd ), CT 45 °C with manufacturers declaration - non essential W24 168,– 168,– 168,– 168,– 168,– 168,– 236,– 236,– 300,– 436,– 776,– 1.120,– a.A. a.A. a.A. a.A. Design acc. to LRoS ( Lloyds Register of Shipping ), CT 45 °C with manufacturers declaration - non essential W25 168,– 168,– 168,– 168,– 168,– 168,– 236,– 236,– 300,– 436,– 776,– 1.120,– a.A. a.A. a.A. a.A. Design acc. to BV ( Bureau Veritas ), CT 45 °C with manufacturers declaration - non essential W26 211,– 211,– 211,– 211,– 211,– 211,– 296,– 296,– 371,– 544,– 969,– 1.390,– a.A. a.A. a.A. a.A. Design acc. to DNV ( Det Norske Veritas ), CT 45 °C with manufacturers declaration - non essential W27 168,– 168,– 168,– 168,– 168,– 168,– 236,– 236,– 300,– 436,– 776,– 1.120,– a.A. a.A. a.A. a.A. Design acc. to ABS ( American Bureau of Shipping ) CT 50 °C with manufacturers declaration - non essential W28 211,– 211,– 211,– 211,– 211,– 211,– 296,– 296,– 371,– 544,– 969,– 1.390,– a.A. a.A. a.A. a.A. Design acc. to RINa ( Registro Italiano Novale ) CT 50 °C with manufacturers declaration - non essential W29 168,– 168,– 168,– 168,– 168,– 168,– 236,– 236,– 300,– 436,– 776,– 1.120,– a.A. a.A. a.A. a.A. Other certifications, motors for upper deck mounting and approvals to classification W99 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N Q60 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q61 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q62 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q63 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q64 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q65 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q66 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q67 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q68 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q69 N N N N N N N N N N N N a.A. a.A. a.A. a.A. D02 N N N N N N N N N N N N 5.500,– 7.700,– 10.000,– 13.300,– Design acc to GL ( German Lloyd ), AT 45 °C, essential drive with manufacturers declaration 1) Design acc to LRoS (Lloyds Register of Shipping), AT 45 °C, essential drive, manufacturers declaration Design acc to BV (Bureau Veritas), AT 45 °C, essential drive with manufacturers declaration 1) Design acc to DNV (Det Norske Veritas), AT 45 °C, essential drive with manufacturers declaration 1) Design acc to ABS (American Bureau of Shipping), AT 50 °C, essential drive, manufacturers declaration Design acc to RINa (Registro Italiano Novale), AT 50 °C, essential drive, manufacturers declaration Design acc to CCS (China), AT 45 °C, essential drive with manufacturers declaration Design acc to USSR (Russia), essential drive with manufacturers declaration Design acc to PR (Poland), essential drive with manufacturers declaration Design acc to NKK (Japan), essential drive with manufacturers declaration 1) 1) 1) 1) 1) 1) 1) Individual certifications Operation at ambient temperatures down to -50°C and transport down to -50°C - antifriction bearings Operation at ambient temperatures down to -40°C and transport down to -40°C - antifriction bearings D03 N N N N N N N N N N N N 2.750,– 3.850,– 5.000,– 6.650,– Operation at ambient temperatures down to -30°C and transport down to -40°C - antifriction bearings D04 N N N N N N N N N N N N 1.400,– 1.900,– 2.500,– 3.300,– Electric design according to NEMA MG1-12 N 1.440,– 1.440,– 1.440,– 1.440,– Certificate according NEPSI - design may differ (different cover size) D32 N N N N N N N N N N N N 1.470,– 1.470,– 1.470,– 1.470,– China Energy Efficiency Label D34 D30 o.MP. N o.MP. N o.MP. N o.MP. N o.MP. N o.MP. N o.MP. N o.MP. N o.MP. N o.MP. N o.MP. N o.MP. N N N N Certificate EAC for Eurasien Customs Union D35 163,– 219,– 219,– 219,– 230,– 230,– 335,– 348,– 348,– 348,– 348,– 348,– 1.470,– 1.470,– 1.470,– 1.470,– Statement of conformity (94/9/EC, ATEX) of an independent authority for Zone 2 motors (Ex nA) D36 N N N N N N N N N N N N 250,– 250,– 250,– 250,– IEC Ex Certificate D37 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 588,– 588,– 588,– 588,– Terminal box on right hand side ( view onto DE ) K09 N N N 247,– 260,– 380,– 409,– 482,– 793,– 1.100,– 1.390,– 1.680,– Terminal box on left hand side ( view onto DE ) K10 793,– 1.100,– 1.390,– 1.680,– Terminal box on top K11 Terminal boxes in IP65 Q71 Cable entry thread metrically different from the standard - thread dimension must be given W30 45,– 45,– 45,– 52,– 52,– 52,– 52,– 52,– 65,– 65,– 65,– 65,– Enlarged connecting for main terminal box - not in combination with K53 (Ex d-terminal box) L00 617,– 805,– 993,– 1.180,– 1.370,– 1.560,– 1.750,– 1.940,– 2.120,– 2.310,– 2.500,– 2.690,– Undrilled cable gland plate at main terminal box L01 N N N N N N N N N N N N Main terminal box in Exd-design with standard terminal studs Q31 N N N N N N N N N N N N Special mechanical designs N □ N □ N N 247,– □ N □ N 260,– □ N 380,– □ N 409,– □ N 482,– □ N □ N □ N □ N □ N N □ □ □ □ o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 1.150,– 1.150,– 1.150,– 1.150,– N N N □ a.A. N N □ N N □ a.A. o.MP. N □ a.A. a.A. Split terminal box W31 N N N N N N N N N 937,– 1.500,– 1.780,– N N N N 1 x NPT - thread for mains supply ( observe the sizes ) - describe thread, cable gland not in our supply W32 113,– 113,– 113,– 130,– 130,– 130,– 130,– 130,– 163,– 163,– 163,– 163,– a.A. a.A. a.A. a.A. 1 x cable gland standard for not armoured cable - for main terminal box K54 55,– 78,– 78,– 78,– 112,– 112,– 212,– 212,– 249,– 249,– 249,– 249,– One cable gland standard thread size for auxiliary connection 1 pc. (not armoured cable) W33 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– N N N N Main terminal with tinned cable lug for copper cable W34 N N N N N N N N N N N N 864,– 864,– 864,– 864,– Clamp terminal for connection without cable lug W35 N N N N N N N N N N N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. Special cable gland - one cable gland for mains connection, Y97 ● and not armoured cable, exact cable data needed identification code Auxiliary terminal box non-Ex grey cast iron design - without removable cable gland plate, N N N N M50 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Auxiliary terminal box-material: stainless steel - not in combination with K53 (Ex d-terminal box) M51 N N N N N N N N N N N N 1.150,– 1.150,– 1.150,– 1.150,– Separate auxiliary box terminal for space heater M52 N N N N N N N N N N N N 576,– 576,– 576,– 576,– Heater in main terminal box P84 N N N N N N N N N N N N 3.500,– 3.500,– 3.500,– 3.500,– Main terminal box flameproof Ex d II C K53 N N N N N N N N N N N N 3.450,– 3.450,– 3.450,– 3.450,– Additional terminal box Ex d II C made of grey cast iron - with standard threats according catalogue; V43 N N N N N N N N N N N N 1.750,– 1.750,– 1.750,– 1.750,– Q75 N N N N N N N N N N N N 576,– 576,– 576,– 576,– Q76 N N N N N N N N N N N N 864,– 864,– 864,– 864,– with metric cable entry thread if thread differ please select (W30), due reducer for cable glands limited if Ex d. Auxiliary terminal box in cast iron design with removable gland plate "undrilled" - not in combination with K53 (Ex d-terminal box) Auxiliary terminal box in cast iron design with removable gland plate "metric thread drilled and sealed with metal plug" - not in combination with K53 (Ex d-terminal box) 1) Acceptance tests must be selected additionally. For example, for the first motor select F83 or F93, and for each additional motor F01. Inclusive of costs for certification authority and inspector, and shaft test if specified by certification authority. LOHER CHEMSTAR for essential drive is possible on request as an ETO option (Engineer To Order) without an option code. Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 62 LOHER CHEMSTAR and VARIO 1PS1 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code and plain text 1PS1. . . - . . . . . - . . . . -Z if required Discount level C Frame size 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Special mechanical designs Additional terminal box Ex e - design / grey cast iron - not in combination with K53 (Ex d-terminal box) W72 N N 220,– 220,– 220,– 220,– 678,– 678,– 678,– 698,– 698,– 698,– a.A. a.A. a.A. a.A. Cable led out radially without terminal box with 1m free cable length (4- or 7-core) W38 N N N 266,– 285,– 304,– 323,– 343,– 362,– 381,– a.A. a.A. N N N N Surcharge each further meter of cable - only in combination with W38 W39 N N N 67,– 91,– 112,– 162,– 162,– 179,– 179,– a.A. a.A. N N N N Connection cable for auxiliaries - only in combination with W38, cable length as main supply W40 N N N 160,– 160,– 160,– 160,– 160,– 160,– 160,– a.A. a.A. N N N N Additional separately supplied terminal box made of grey-cast iron with baseplate - main terminal box W41 a.A. a.A. a.A. 228,– 228,– 228,– 348,– 348,– 428,– 428,– a.A. a.A. N N N N Cable entry side DE K83 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. Cable entry side NDE K84 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. Turn of the terminal box about 180 ° K85 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. Vibration severity grade A - IEC 60034-14 K01 □ □ □ Vibration severity grade B - IEC 60034-14 - if inverter duty for smallest and highest speed of speed range only K02 516,– 569,– 576,– 620,– 620,– 629,– 673,– 798,– 980,– 1.150,– 1.470,– 2.580,– 1.500,– 2.250,– 3.000,– 3.750,– Shaft and flange with increased precision to DIN42955-R K04 149,– 149,– 149,– 200,– 262,– 367,– 478,– 576,– 700,– 871,– 1.020,– 1.170,– 2.000,– 2.250,– 2.500,– 3.000,– Radial sealing ring on DE-side for flange-mounted types (oil-tight) horizontal mounting K17 58,– 66,– 68,– 75,– 92,– 110,– 143,– 205,– 262,– 338,– 402,– 475,– N N N N Radial sealing ring on DE-side for vertical flange-mounted types (oil-tight) W43 104,– 119,– 122,– 135,– 166,– 197,– 256,– 369,– 478,– 607,– 722,– 840,– N N N Labyrinth sealing for external bearing seal W44 a.A. a.A. a.A. a.A. a.A. a.A. a.A. 698,– 889,– 1.140,– 1.320,– 2.180,– Bearing for increased lateral forces (roller bearing DE) including regreasing device - including K40 K20 N N N N 519,– 572,– 632,– 691,– 714,– 738,– 369,– a.A. Axial thrust bearing V20 N N N N N N N N N N Regreasing device DE/NDE K40 N N N N 419,– 472,– 532,– 591,– 614,– 638,– Grease-collecting chamber if regreasing is applied W45 Bearing insulation NDE for antifriction bearing - binding for frame size 315 - 500 at inverter operation L27 Shaft earthing device - down to -20°C V36 Fixed bearing DE K94 Fixed bearing NDE L04 certificate acc. Ex e Special grease Klüber Staburags NBU8EP - ETO-Option (Engineer To Order) without order code Special grease Klüber Isoflex SL2 - ETO-Option (Engineer To Order) without order code Special grease Barierta L55/2 - ETO-Option (Engineer To Order) without order code Other special grease - ETO-Option (Engineer To Order) without order code PT100 bearing in tolerance class A with calibration certificate - only in combination with Q44 V76 Sensor for enclosure vibration monitoring Bently Nevada Accelerometers without separate junction box □ □ □ □ □ □ □ □ □ N □ □ □ □ □ a.A. N □ □ a.A. □ □ a.A. o.MP. N □ a.A. a.A. □ o.MP. □ a.A. a.A. □ a.A. □ N N N N N N N N N N N N N N N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. 2.100,– 2.230,– 2.340,– 2.430,– 2.550,– 1.800,– 2.000,– 2.000,– 2.000,– N □ N □ N □ N □ N □ N □ N □ N □ N □ N □ N □ N □ a.A. □ a.A. □ a.A. □ a.A. □ 189,– 189,– 194,– 210,– 233,– 273,– 310,– 340,– 378,– 431,– 536,– 640,– N N N N 23,– 23,– 23,– 23,– 46,– 46,– 46,– 46,– 48,– 48,– 205,– 246,– a.A. a.A. a.A. a.A. 30,– 30,– 46,– 92,– 125,– 139,– 139,– 139,– 180,– 180,– 915,– 1.080,– a.A. a.A. a.A. a.A. 278,– 364,– 579,– 1.150,– 1.610,– 1.760,– 1.760,– 1.800,– 1.880,– 2.510,– 3.200,– 3.530,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N N N N N N N N N 2.300,– 2.300,– 2.300,– 2.300,– V16 N N N N N N N N N N N N 4.320,– 4.320,– 4.320,– 4.320,– Bearing ventilation at DE for lower bearing temperature for antifriction bearing design grease lubricated V17 N N N N N N N N N N N N 2.850,– 3.200,– 3.450,– 3.700,– Bearing insulation DE- and NDE (DE linked to earth) for antifriction bearing design - V18 N N N N N N N N N N N N 5.150,– 5.150,– 5.760,– 5.760,– Grease extractors for DE and NDE V21 N N N N N N N N N N N N N N N 3.450,– Automatic grease lubricator DE and NDE (suitable for ambient temperature from -15 up to + 50°C) V22 N N N N N N N N N N N N 2.000,– 2.000,– 2.000,– 2.850,– Enlarged grease chamber DE and NDE V25 N N N N N N N N N N 1.750,– 2.300,– 2.300,– External earthing ( additionally ) W46 110,– 110,– 114,– 114,– 125,– 143,– 155,– 182,– 204,– 231,– 271,– 300,– N N N N VIK design - incl. W14, W69 K30 310,– 363,– 419,– 479,– 546,– 618,– 695,– 778,– 867,– 963,– 1.070,– 1.280,– 3.000,– 4.000,– a.A. N LOHER CHEMSTAR Plus design, including VIK design; IP56 - including K30, K51, W14, W69 and W09 578,– 657,– 713,– 773,– 840,– 983,– 1.060,– 1.140,– 1.230,– 1.330,– 1.540,– 1.750,– N N N N - per sensor horizontal mounting only, (vertical mounting on request) N N 1.750,– IP66 shaft sealing, vibration grade similar grade B Second rating plate separately K31 22,– 22,– 22,– 22,– 22,– 70,– 70,– 70,– 70,– 70,– 70,– 70,– 288,– 288,– 288,– 288,– Second rating plate installed in terminal box W47 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 288,– 288,– 288,– 288,– Additional plate for customer data (each plate) - data / text have to be give with order Y82 ● and 43,– 43,– 43,– 43,– 43,– 71,– 71,– 71,– 89,– 89,– 112,– 115,– 144,– 144,– 144,– 144,– N identification code Additional data on motor rating plate and on packing sticker - max. 20 digits Y84 43,– 43,– 43,– 43,– 43,– 71,– 71,– 71,– 89,– 89,– 112,– 115,– N N N Plates made of stainless steel W48 55,– 55,– 55,– 55,– 55,– 55,– 70,– 70,– 70,– 70,– 70,– 70,– N N N N Plates in other languages as German or English - mains rating plate or auxiliary plate, W49 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.150,– 1.150,– 1.150,– 1.150,– factory clarification required Additional measures for 2 up to 4 years storage to storage instructions W50 45,– 54,– 65,– 78,– 97,– 106,– 118,– 137,– 143,– 203,– 220,– 300,– 864,– 864,– 864,– 1.150,– Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 63 LOHER CHEMSTAR and VARIO 1PS1 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code and plain text 1PS1. . . - . . . . . - . . . . -Z if required Discount level C Frame size 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Special mechanical designs Space heater 230 V - preferably choose M13 N 2.250,– 2.500,– 2.750,– 3.000,– Space heater 115 V - preferably choose M12 K46 N N N N N N N N N N N N 2.500,– 2.750,– 3.000,– 3.250,– Space heater 110 - 120 V (min. 100 V, max. 132 V) M12 K45 N N N N N N N N N N N N 2.000,– 2.000,– 2.400,– 2.800,– Space heater 210 - 250 V (min. 200 V, max. 264 V) M13 N N N N N N N N N N N N 2.000,– 2.000,– 2.400,– 2.800,– Space heater rated voltage 110-120 V (min. 100 V, max. 132 V) Ex e II T 3 M14 N N N N N N N N N N N N 3.000,– 3.000,– 3.300,– 3.600,– Space heater rated voltage 220-240 V (min. 200 V, max. 264 V) Ex e II T 3 M15 N N N N N N N N N N N N 3.000,– 3.000,– 3.300,– 3.600,– Space heater 208 - 254V - 1 phase (self limitating for Ex e, Ex n) W88 536,– 599,– 638,– 666,– 936,– 1.040,– 1.150,– 1.310,– 1.450,– 1.640,– 1.640,– 1.910,– N N N Heater with thermostat N N N N N N N N N N N N V75 N N N N N N N N N N N N 7.200,– 7.200,– 7.200,– 7.200,– K16 278,– 296,– 324,– 378,– 451,– 544,– 640,– 747,– 860,– 1.020,– 1.240,– 1.400,– 4.000,– 4.500,– 5.250,– 6.000,– Non-standard cylindrical shaft end (diameter identical or smaller as standard) - Y55 ● and 329,– 380,– 450,– 502,– 595,– 680,– 764,– 904,– 1.010,– 1.140,– 1.350,– 2.070,– 1.150,– 1.150,– 1.150,– 1.350,– in case of significant different diameter, especially high pole motors due high torque stress, identification N Second standard shaft end - VARIO for 50% torque, CHEMSTAR for 100% torque factory clarification required 3) 3) code Shaft of material 1.7225 3) W51 704,– 704,– 749,– 771,– 1.070,– 1.070,– 1.350,– 1.470,– 1.580,– 1.580,– 1.580,– 2.200,– N N N Shaft of material 1.4021 3) W52 756,– 756,– 787,– 1.010,– 1.500,– 1.780,– 2.010,– a.A. a.A. a.A. a.A. a.A. N N N N W53 1.480,– 1.480,– 1.600,– 1.940,– 2.170,– 2.170,– 2.760,– a.A. a.A. a.A. a.A. a.A. N N N N 2.200,– 3.000,– 3.800,– 4.600,– □ □ □ □ □ 3) = Basis 1 - 4 pcs. / calculate factor 0.5 for basis > 5 - 19 pcs. ! Shaft end of special steel butt-welded ( Material 1.4571 ) Shaft material of alloy steel (1.7225 - 42CrMo4) - only until -40° C L72 N N N N N N N N N N N N Welded standard stator housing for TEFC motors - factory clarification is mandatory, W54 N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. dimensions may differ Welded CU-rotor ( copper-bar rotor ) W55 N N N a.A. 2.910,– 3.110,– 4.220,– 5.270,– 5.560,– 7.310,– 10.300,– 12.200,– □ □ □ Second shaft end for IMB3 up to 100% torque; cylindrical with key Q21 N N N N N N N N N N N N 5.500,– 6.200,– 6.800,– Special rotor for heavy duty starting (e.g. DS-rotor or brass cage rotor) - type test needed Q22 N N N N N N N N N N N N 4.300,– 5.000,– 5.750,– Asynchronous generator design with 1.8 fold runaway speed - 4 pole or higher pole, only W56 109,– 134,– 163,– 206,– 258,– 331,– 404,– 598,– 754,– 965,– 1.250,– 1.620,– N N N Enclosure IP56 K51 268,– 294,– 294,– 294,– 294,– 364,– 364,– 364,– 364,– 364,– 476,– 622,– □ Enclosure IP65 K50 295,– 323,– 323,– 323,– 323,– 401,– 401,– 401,– 401,– 401,– 523,– 684,– 1.350,– 2.890,– 3.350,– Enclosure IP66 L94 369,– 404,– 404,– 404,– 404,– 501,– 501,– 501,– 501,– 501,– 654,– 855,– N N N N Enclosure IP67 K93 N N N N N N N N N N N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. 6.950,– 7.330,– 8.210,– 8.730,– 9.840,– 12.500,– 14.000,– 16.000,– 20.000,– 980,– 1.100,– 1.250,– 1.390,– W58 a.A. a.A. a.A. a.A. Condensate drain holes sealed with screw Enclosure IP67 without level switch (resin material for terminal box protection will be shipped as extra package; W60 N N N N Increased tropicalization, humidity ≥ 80% - LOHER CHEMSTAR incl. V10 and W71, W61 543,– 630,– 702,– 830,– □ □ 7.700,– 6.650,– N □ 3.350,– 8 m submerged, max. 72 h) □ □ □ □ □ □ 1.600,– 1.880,– □ □ 250,– 250,– 250,– 250,– 2.220,– 2.610,– 2.000,– 2.300,– 2.600,– 2.900,– LOHER VARIO incl. V10 and P45 Tropical design for outdoor onshore installation L28 Design without fan and fan cover - motor mounted in air stream; without external air stream cooling W62 N N N N N N N N N N N N 2.000,– 2.300,– 2.600,– 2.900,– 132,– 132,– 132,– 132,– 132,– 186,– 186,– 186,– 227,– 227,– 227,– 227,– a.A. a.A. a.A. a.A. factory clarification required, due reduced rating Outer fan with corrosion protection in case of metal fan W63 95,– 113,– 130,– 270,– 315,– Fan of aluminium W64 158,– 188,– 217,– 246,– 275,– 304,– 333,– 363,– N N Fan of steel W65 a.A. a.A. a.A. 1.170,– 148,– 1.170,– 165,– 1.360,– 183,– 1.360,– 200,– 1.690,– 218,– 1.690,– 235,– 1.690,– 253,– 1.710,– 1.710,– □ □ □ □ Outer-fan of brass W66 a.A. a.A. a.A. 1.520,– 1.520,– 1.770,– 1.770,– 2.220,– 2.220,– 2.220,– 2.220,– 2.890,– 1.750,– 2.000,– 2.250,– 2.500,– Outer fan of stainless steel V94 N N N N N N N N N N N N 4.500,– 5.000,– 5.500,– 6.000,– Special ventilation for on deck motors W67 N N N N 2.730,– 2.730,– 2.780,– 2.910,– 2.910,– 2.960,– 3.040,– 3.140,– a.A. a.A. a.A. a.A. Fan cover of steel sheet (3 mm thickness) W68 a.A. a.A. 1.360,– 1.360,– 1.360,– 1.360,– 1.360,– 1.360,– 1.360,– 1.360,– 1.430,– 1.930,– a.A. a.A. a.A. a.A. Galvanized fan cowl - in K30 and W09 incl. W69 162,– 191,– 219,– 248,– 277,– 306,– 335,– 364,– 392,– 421,– 450,– 480,– a.A. a.A. a.A. a.A. Noise level 3 for rotation CW seen on DE - only for 2-pole motors K37 N N N 767,– 767,– 767,– 767,– 778,– 811,– 878,– 956,– 1.030,– N N N Noise level 3 for rotation CCW seen on DE - only for 2-pole motors K38 N N N 767,– 767,– 767,– 767,– 778,– 811,– 878,– 956,– 1.030,– N N N N Clockwise rotation viewed to DE - direction of rotation is mandatory for motors frame size 355 in 2-/4-pole design K97 N N N N N N N N N N N o.MP. o.MP. o.MP. o.MP. o.MP. Anti-clockwise rotation viewed to DE - direction of rotation is mandatory for motors frame size 355 in 2-/4-pole K98 N N N N N N N N N N N o.MP. o.MP. o.MP. o.MP. o.MP. Noise reduction: silencer for air inlet (GG3) - only in combination with K97 or K98 L20 N N N N N N N N N N N N 2.200,– 3.080,– 4.000,– 4.000,– Stainless steel grid for air inlet silencer - only in combination with L20 L25 N N N N N N N N N N N N 576,– 576,– 576,– 576,– Noise cabinet with inspection door - zinc galvanized unpainted - noise reduction approx. 15dB(A) based on GG1 V32 N N N N N N N N N N N N 18.500,– 20.500,– 22.400,– 25.000,– Noise cabinet with inspection door - V4A unpainted - noise reduction approx. 15dB(A) based on GG1 V35 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Noise jacket, noise reduction approx. 3-5 dB(A) compared to standard GG1 V34 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Operation for both rotations - from 355 in 2-/4-pole increased noise level and reduced power K99 a.A. 3.000,– 3.850,– 4.750,– a.A. Increased switching cycles (max. 3000 starts per year) Q23 N 1.650,– 2.310,– 3.000,– 3.990,– □ 700,– N 850,– N 980,– N 1.100,– N N N design Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. □ □ N □ N □ N 64 □ N □ N □ N □ N □ N □ N □ N N LOHER CHEMSTAR and VARIO 1PS1 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code and plain text 1PS1. . . - . . . . . - . . . . -Z if required Discount level C Frame size 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Special mechanical designs Balancing with full key 207,– 1.440,– 1.440,– 1.440,– 1.440,– Support ring for coupling guard L15 N N N N N N N N N N N N 2.000,– 2.000,– 2.000,– 2.500,– Fitting of coupling half (customer-supplied, ready machined and balanced) - supplied 4 weeks L17 L68 114,– a.A. 114,– a.A. 114,– a.A. 132,– a.A. 132,– a.A. 166,– a.A. 166,– a.A. 207,– a.A. 207,– a.A. 207,– a.A. 207,– a.A. a.A. 2.300,– 2.300,– 2.300,– 3.450,– ahead testing date Machine mounting: bolts, shims and tapered pins for mounting on steel foundation L31 N N N N N N N N N N N N 2.000,– 2.300,– 2.600,– 2.900,– Machine mounting: anchor bolts, sole plates and SS-shims for fixing on concrete base L33 N N N N N N N N N N N N 5.750,– 6.000,– 6.300,– 6.800,– □ □ □ □ Half key balancing L69 Heavy duty rolling contact bearings for extreme radial forces L96 Stainless steel screws and plates W71 □ □ □ □ □ □ □ □ □ □ □ □ N N N N N N N N N N N N a.A. a.A. a.A. N 185,– 224,– 242,– 307,– 380,– 413,– 464,– 500,– 584,– 738,– 920,– 1.150,– N N N N Stainless steel external bolts P45 N N N N N N N N N N N N 1.150,– 1.400,– 1.650,– 1.900,– Ambient temperature to -40°C; preheating before operation necessary - due needed heater power W73 N N N N N N N N N N N N a.A. a.A. a.A. a.A. factory clarification required, heating via winding may be needed. Installed heating elements for surcharge. Ambient temperature to -40°C; preheating before operation necessary - factory clarification required W77 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N Ambient temperature to -60°C; preheating before operation necessary - factory clarification required W78 N N N N N N N N N N a.A. a.A. N N N N Ambient temperature to -40°C; Ex nA II and Ex e II; without preheating before operation W79 260,– 330,– 400,– 470,– 540,– 610,– 680,– 750,– 820,– 890,– 960,– 1.030,– N N N N Ambient temperature to -55°C; without preheating before starting W98 953,– 1.020,– 1.120,– 1.300,– 1.610,– 1.870,– 2.150,– 2.560,– 3.000,– 3.610,– 4.390,– 4.850,– Mounted pulse transmitter 1024 pulses/rpm - 10 - 30 V, HTL - level - flameproof design W96 N N N 7.910,– 7.910,– 7.910,– 7.910,– 8.420,– 8.420,– 9.110,– 9.400,– 9.400,– N N N N Speed encoder Ex design (preferred brand) - 1024 pulses/rpm - 10 - 30 V, HTL - level - flameproof design V72 N N N N N N N N N N N N 5.760,– 5.760,– 5.760,– 5.760,– Speed encoder Ex-design with integrated shaft earthing device (Loher preferred brand) - 1024 pulses/rpm - V77 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Mechanical protection for speed encoder - in combination with V72, V77 M68 N N N N N N N N N N N N 1.150,– 1.150,– 1.150,– 1.150,– Mounted forced ventilation radial W81 N N N N N N N a.A. a.A. a.A. a.A. a.A. N N N N Forced ventilation NDE - for Ex motors - axial forced ventilation V28 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Reverse lock for direction of rotation right seen onto DE ( left locked ) - dimensions may differ G48 N N N 2.380,– 2.620,– 2.620,– 2.780,– 3.020,– 3.760,– 4.560,– 4.780,– a.A. 5.760,– 6.500,– 7.200,– 8.650,– Reverse lock for direction of rotation left seen onto DE ( right locked ) - dimensions may differ G49 N N N 2.380,– 2.620,– 2.620,– 2.780,– 3.020,– 3.760,– 4.560,– 4.780,– a.A. 5.760,– 6.500,– 7.200,– 8.650,– Tapered shaft end with shaft nut T36 N N N N N N N N N N N N 9.500,– 9.500,– 9.500,– 9.500,– Sun protection shield - fixing parts of mild steel, cover of SS unpainted for vertical motors V87 N N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. 5.750,– 6.500,– 7.250,– 8.000,– Sun protection shield - fixing parts of mild steel, cover of SS unpainted for horizontal motors V99 N N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. 4.000,– 4.000,– 4.500,– 5.000,– Preparation for SPM bearing monitoring, only thread M8 for adapter W84 N N N 287,– 287,– 287,– 287,– 287,– 287,– 287,– 287,– 373,– 864,– 864,– 864,– 864,– Drain & breather for auxiliary terminal box IP56 - not in combination with V43 (Ex d terminal box) Q77 N N N N N N N N N N N N 576,– 576,– 576,– 576,– Drain & breather for main terminal box IP56 - not in combination with K53 (Ex d terminal box) Q78 N N N N N N N N N N N N 576,– 576,– 576,– 576,– 10 - 30 V, HTL - level - flameproof design; down to -20° C only; bearing insulation to be added Machined surface on motor feet with dowel pin holes Q94 N N N N N N N N N N N N 1.730,– 1.730,– 1.730,– 1.730,– Base frame for height adaptation of max. 2 frame sizes difference Q96 N N N N N N N N N N N N 11.500,– 11.500,– 13.000,– 14.500,– Adaptation of foot- & shaft dimensions to next higher frame size (no terminal box adaptation!) Q97 N N N N N N N N N N N N 5.500,– 6.500,– 7.500,– 8.500,– Adaptation of flange dimensions and flansh fixing holes Provisioned for lateral installation of sun shield Q98 N N N N N N N N N N N N 3.500,– 4.800,– 5.900,– 7.000,– Q99 N N N N N N N N N N N N 2.000,– 2.000,– 2.000,– 2.500,– Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 65 LOHER CHEMSTAR and VARIO 1PS1 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code and plain text 1PS1. . . - . . . . . - . . . . -Z if required Discount level C Frame size 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Special mechanical designs SPM bearing monitoring: Measuring nipple system 32 - thread M8, DE + NDE G50 N N N 621,– 1.150,– 1.150,– 1.150,– 1.150,– Shock pulse measurement (SPM), fixed sensor and distribution box H05 N N N N N N N N N N N N 4.000,– 4.000,– 4.000,– 4.000,– SPM bearing monitoring: Transducer system 40 - thread M8 W85 N N N 4.350,– 4.350,– 4.350,– 4.350,– 4.350,– 4.350,– 4.350,– 4.350,– 4.350,– N N N N Bearing temperature monitoring with PTC thermistors on DE/NDE W86 N N N N a.A. a.A. 1.110,– 1.110,– 1.110,– 1.110,– 1.110,– 1.110,– N N N N Speed monitoring by inductive proximity switches, Fa. Pepperl + Fuchs A03 N N N N N N N N N N N N 2.300,– 2.300,– 2.300,– 2.300,– 2 single RTD's PT100 for antifriction bearing - 3 or 4 wire from terminal box, rolling-contact bearing - A40 N N N N N N N N a.A. a.A. a.A. a.A. 1.440,– 1.440,– 1.440,– 1.440,– 478,– 478,– 478,– 478,– 478,– 478,– 478,– 478,– 1 x DE and 1 x NDE 2 double resistance thermometers PT100 for 4-wire connection from terminal box, rolling-contact bearing - A42 N N N N N N N N N N N N 2.300,– 2.300,– 2.300,– 2.300,– 2 capillary dial-type thermometers without contacts A70 N N N N N N N N N N N N 2.300,– 2.300,– 2.300,– 2.300,– 2 capillary dial-type thermometers with 2 normally open contacts A71 N N N N N N N N N N N N 3.450,– 3.450,– 3.450,– 3.450,– Bearing temperature monitoring with 1 x PT100 each bearing in 2-wire connection - 2-wire from terminal box A72 N N N N N N 1.390,– 1.390,– 1.390,– 1.390,– 1.390,– 1.390,– N N N N One dial type thermometer with 2 contacts, capillary principle - Ex i design without supply unit V89 N N N N N N N N N N N N 2.600,– 2.600,– 2.600,– 2.600,– 1 x DE and 1 x NDE Engraved tag plate fixed on terminal box V96 N N N N N N N N N N N N 288,– 288,– 288,– 288,– Shims of SS-material (V4A/AISI316) - 4mm/motor foot - not laminated Q92 N N N N N N N N N N N N 1.730,– 1.730,– 1.730,– 2.000,– Shims of brass material - 4mm/motor foot - not laminated V31 N N N N N N N N N N N N 1.440,– 1.440,– 1.440,– 2.150,– Slotted feet holes Q95 N N N N N N N N N N N N 1.730,– 1.730,– 1.730,– 1.730,– Form coil winding LV-motors V01 N N N N N N N N N N N N a.A. a.A. a.A. a.A. 2 metal test sheets (100 x 150mm) with paint layer for special paint inspection V08 N N N N N N N N N N N N 1.150,– 1.150,– 1.150,– 1.150,– Impact protection - for accessory equipment, per equipment M81 N N N N N N N N N N N N 720,– 720,– 720,– 720,– Brackets for lifting and shifting P42 N N N N N N N N N N N N 2.500,– 2.500,– 2.500,– 2.500,– Provision for housing vibration probe, one flat surface with thread M8 x 1 P63 N N N N N N N N N N N N 720,– 720,– 720,– 720,– Pressure oil connection with cylindrical or stepped shaft end instead of feather key connection Y85 ● and N N N N N N N N N N N N 6.050,– 6.050,– 6.050,– 6.050,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N B15 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. Extension of liability of defects of 12 to 24 months Q80 39,– 47,– 53,– 65,– 88,– 108,– 138,– 176,– 219,– 314,– 584,– 1.080,– 1.210,– 1.690,– 2.200,– 2.930,– Extension of liability of defects of 18 to 30 months Q81 61,– 72,– 82,– 100,– 137,– 166,– 213,– 272,– 339,– 485,– 903,– 1.670,– 1.870,– 2.620,– 3.400,– 4.520,– Extension of liability of defects of 24 to 36 months Q82 78,– 94,– 106,– 129,– 177,– 215,– 276,– 352,– 438,– 627,– 1.170,– 2.170,– 2.420,– 3.390,– 4.400,– 5.850,– identification code "High-Speed-Motors" for speed range 3600 < N <= 6000 RPM, factory clarification required torque W87 characteristic and nominal frequency adjusted design, performance test of original system may be needed "High-Speed-Motors" for speed range >6000 RPM, factory clarification required torque characteristic and nominal frequency adjusted design, performance test of original system may be needed; ETO-Option (Engineer To Order) without order code Retrofit (description of the special design separately) - adaptation to an existing motor Extension of the liability for defects Extension of liability of defects of 30 to 42 months Q83 110,– 132,– 150,– 182,– 249,– 303,– 389,– 496,– Extension of liability of defects of 36 to 48 months Extension of liability of defects of 48 to 60 months Q84 142,– 170,– 194,– 235,– 322,– 391,– 502,– 640,– 797,– 1.140,– 2.130,– 3.940,– 4.400,– 6.160,– 8.000,– 10.600,– Q85 199,– 239,– 271,– 329,– 450,– 548,– 702,– 897,– 1.120,– 1.600,– 2.980,– 5.510,– 6.160,– 8.620,– 11.200,– 14.900,– □ = Standard version o.MP. = Without surcharge ● = This order code only determines the price of the version - additional plain text is required. a.A. = On request N = Not available 1) Performance test have to be selected separately. Please select or first motor e.g. F83 or F93, for each further motor F01. Cost of third party inspector, certifying bureau or if mandatory shaft material test is included. LOHER CHEMSTAR for essential drive on request available, ETO-option (Engineer To Order) without option code. Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 66 618,– 884,– 1.650,– 3.050,– 3.410,– 4.770,– 6.200,– 8.250,– LOHER CHEMSTAR and VARIO 1PS0 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE2, 0.75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 60Hz kW FS kW IE class 2-pole: 3000 rpm at 50Hz LOHER CHEMSTAR 1,5 90 L 1,8 IE2 2,2 90 L 2,6 IE2 3 100 L 3,6 IE2 4 112 M 4,5 IE2 5,5 132 S 6,6 IE2 7,5 132 S 9 IE2 11 160 M 13,2 IE2 15 160 M 18 IE2 18,5 160 L 22 IE2 22 180 M 26 IE2 30 200 L 36 IE2 37 200 L 44 IE2 45 225 M 54 IE2 55 250 M 66 IE2 75 280 S 90 IE2 90 280 M 110 IE2 110 315 S 125 IE2 132 315 M 145 IE2 160 315 M 180 IE2 200 315 L 220 IE2 250 315 L 270 IE2 315 355 L 315 IE2 Motor type Article No. ANGA-090LR-02 ANGA-090LS-02 ANGA-100LS-02 ANGA-112MS-02 ANGA-132SR-02 ANGA-132SS-02 ANGA-160MR-02 ANGA-160MS-02 ANGA-160LS-02 ANGA-180MS-02 ANGA-200LR-02 ANGA-200LS-02 ANGA-225MS-02 ANGA-250MM-02 ANGA-280SL-02 ANGA-280MM-02 ANGA-315SL-02 ANGA-315ML-02 ANGA-315MN-02 ANGA-315LL-02 ANGA-315LN-02 ANGA-355LB-02 1PS00951PS00981PS01061PS01131PS01311PS01321PS01631PS01651PS01661PS01831PS02061PS02081PS02231PS02531PS02801PS02831PS03111PS03131PS03151PS03161PS03181PS0356- Price for 1 unit for IM B3 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA3 -0AA2 1.880,– 2.070,– 2.190,– 2.400,– 2.710,– 3.100,– 3.630,– 4.330,– 4.640,– 5.060,– 6.240,– 7.350,– 8.550,– 9.880,– 13.200,– 15.100,– 18.300,– 21.200,– 25.400,– 30.700,– 37.900,– 47.900,– Discount level A Frame size LOHER VARIO 355 355 L 400 355 L 450 355 L 450 400 L 500 400 L 560 400 L 630 400 L 630 450 L 710 450 L 800 450 L 900 450 L 1000 500 L 1200 500 L 400 450 500 500 560 630 710 800 900 a.A. a.A. a.A. a.A. IE2 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) ANSA-355LC-02 ANSA-355LD-02 ANSA-355LX-02 ANSA-400LL-02 ANSA-400LN-02 ANSA-400LN-02 ANSA-400LX-02 ANSA-450LL-02 ANSA-450LL-02 ANSA-450LN-02 ANSA-450LN-02 ANSA-500LL-02 ANSA-500LN-02 1PS03571PS03581PS03581PS04041PS04051PS04071PS04081PS04531PS04551PS04571PS04581PS05071PS0508- Operating modes Frame size Mains-fed operation 90 ... 450 (<= 800 kW) Converter-fed operation, standard insulation 90 ... 400 Converter-fed operation with special insulation 160 ... 500 (derating approx. 5 %) 450 (> 800 kW) ... 500 Mains-fed operation, pre-formed coil Converter-fed operation, pre-formed coil 450 ... 500 Voltages 690 VD, 50Hz 355 ... 500 230 V/400 V, 50 Hz 90 ... 112 500 VY, 50 Hz 90 ... 315 500 VD, 50 Hz 355 ... 450 400 V/690 V, 50 Hz 90 ... 400 690 VY, 50 Hz 90 ... 400 For other voltages see options list 90 ... 500 Types of construction IM B3 90 ... 500 IM B5 90 ... 315 IM B34 90 ... 112 IM B14 90 ... 112 IM V1/canopy 90 ... 400 IM B35 90 ... 500 IM V1, without canopy 90 … 355 For other types of construction see options list 90 ... 500 1) Outside the IE code classification according to IEC60034-30. BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ Order code - 3 4 … 0 1 2 3 4 6 8 9 67 45.400,– 47.600,– 55.600,– 57.500,– 62.500,– 70.100,– 74.900,– 82.300,– 85.300,– 90.300,– 103.000,– 129.000,– 144.000,– 0 1 2 0 1 3 5 6 8 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications The prices are recommended without obligation Price list LOHER Motors 2015 Version a. -0AA0 -0AA0 -0AA0 -0AA0 -0AA0 -0AA0 -0AA0 -0AA0 -0AA0 -0AA0 -0AA0 -0AA0 -0AA0 … Discount level C Price for 1 unit for IM B3, 50Hz, mains operation Options acc. surcharge price list 1PS0… Prated 50Hz LOHER CHEMSTAR and VARIO 1PS0 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE2, 0.75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 60Hz kW FS kW IE class 4-pole: 1500 rpm at 50Hz LOHER CHEMSTAR 1,1 90 L 1,3 IE2 1,5 90 L 1,8 IE2 2,2 100 L 2,6 IE2 3 100 L 3,6 IE2 4 112 M 4,8 IE2 5,5 132 S 6,6 IE2 7,5 132 M 9 IE2 11 160 M 13 IE2 15 160 L 18 IE2 18,5 180 M 22 IE2 22 180 L 26 IE2 30 200 L 36 IE2 37 225 S 44 IE2 45 225 M 54 IE2 55 250 M 66 IE2 75 280 S 90 IE2 90 280 M 110 IE2 110 315 S 125 IE2 132 315 M 145 IE2 160 315 M 180 IE2 200 315 L 220 IE2 250 315 L 270 IE2 315 355 L 315 IE2 315 355 L 315 IE2 Motor type Article No. ANGA-090LR-04 ANGA-090LS-04 ANGA-100LR-04 ANGA-100LS-04 ANGA-112MS-04 ANGA-132SR-04 ANGA-132MS-04 ANGA-160MR-04 ANGA-160LS-04 ANGA-180MR-04 ANGA-180LS-04 ANGA-200LS-04 ANGA-225SR-04 ANGA-225MS-04 ANGA-250MM-04 ANGA-280SL-04 ANGA-280MM-04 ANGA-315SL-04 ANGA-315ML-04 ANGA-315MN-04 ANGA-315LL-04 ANGA-315LM-04 ANGA-355LB-04 ANGA-355LB-042) 1PS00951PS00981PS01061PS01081PS01131PS01311PS01331PS01631PS01661PS01831PS01861PS02061PS02201PS02231PS02531PS02801PS02831PS03111PS03131PS03151PS03161PS03171PS03561PS0356- Price for 1 unit for IM B3 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA2 -0BB2 1.700,– 1.820,– 2.010,– 2.120,– 2.330,– 2.640,– 3.000,– 3.520,– 4.190,– 4.500,– 4.900,– 6.010,– 7.120,– 8.250,– 9.560,– 12.800,– 14.600,– 17.600,– 20.400,– 24.300,– 29.300,– 36.000,– 45.300,– 49.400,– LOHER VARIO 355 355 L 400 355 L 450 355 L 500 355 L 500 400 L 560 400 L 630 400 L 710 400 L 800 450 L 900 450 L 950 450 L 1000 500 L 1120 500 L 1250 500 L 1400 500 L 400 450 500 560 560 630 710 800 900 1000 a.A. a.A. a.A. a.A. a.A. IE2 ANSA-355LC-04 ANSA-355LD-04 ANSA-355LN-04 ANSA-355LX-04 ANSA-400LL-04 ANSA-400LN-04 ANSA-400LN-04 ANSA-400LX-04 ANSA-450LL-04 ANSA-450LN-04 ANSA-450LN-04 ANSA-500LL-04 ANSA-500LL-04 ANSA-500LN-04 ANSA-500LN-04 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) Operating modes Mains-fed operation Converter-fed operation, standard insulation Converter-fed operation with special insulation (derating approx. 5 %) Mains-fed operation, pre-formed coil Converter-fed operation, pre-formed coil Voltages 690 VD, 50Hz 230 V/400 V, 50 Hz 500 VY, 50 Hz 500 VD, 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 IM V1, without canopy For other types of construction see options list 1PS03581PS03501PS03571PS03581PS04041PS04051PS04071PS04081PS04551PS04571PS04581PS05041PS05051PS05071PS0508- BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 43.800,– 46.400,– 53.400,– 55.800,– 61.700,– 65.900,– 72.300,– 78.000,– 83.300,– 95.100,– 104.000,– 111.000,– 117.000,– 129.000,– 131.000,– Frame size 90 ... 450 (<= 800 kW) 90 ... 400 160 ... 500 0 1 2 Order code - 450 (> 800 kW) ... 500 450 ... 500 3 4 - 355 ... 500 90 ... 112 90 ... 315 355 ... 450 90 ... 400 90 ... 400 90 ... 500 90 ... 500 90 ... 315 90 ... 112 90 ... 112 90 ... 400 90 ... 500 90 … 355 90 ... 500 1) Outside the IE code classification according to IEC60034-30. 2) Motor with special rotor (Cu). … 0 1 3 5 6 8 9 0 1 2 3 4 6 8 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 68 … Discount level C Price for 1 unit for IM B3, 50Hz, mains operation Options acc. surcharge price list 1PS0… Frame size Discount level A Prated 50Hz LOHER CHEMSTAR and VARIO 1PS0 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE2, 0.75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 60Hz kW FS kW IE class 6-pole: 1000 rpm at 50Hz LOHER CHEMSTAR 0,75 90 L 0,75 IE2 1,1 90 L 0,9 IE2 1,5 100 L 1,25 IE2 2,2 112 M 1,8 IE2 3 132 S 3 IE2 4 132 M 4 IE2 5,5 132 M 5,5 IE2 7,5 160 M 7,5 IE2 11 160 L 11 IE2 15 180 L 15 IE2 18,5 200 L 18,5 IE2 22 200 L 22 IE2 30 225 M 30 IE2 37 250 M 37 IE2 45 280 S 45 IE2 55 280 M 55 IE2 75 315 S 75 IE2 90 315 M 90 IE2 110 315 M 110 IE2 132 315 M 132 IE2 160 315 L 160 IE2 200 315 L 200 IE2 200 315 L a.A. IE2 250 355 L 250 IE2 Motor type Article No. ANGA-090LR-06 ANGA-090LS-06 ANGA-100LS-06 ANGA-112MS-06 ANGA-132SR-06 ANGA-132MR-06 ANGA-132MS-06 ANGA-160MR-06 ANGA-160LS-06 ANGA-180LS-06 ANGA-200LR-06 ANGA-200LS-06 ANGA-225MS-06 ANGA-250MM-06 ANGA-280SL-06 ANGA-280MM-06 ANGA-315SL-06 ANGA-315ML-06 ANGA-315MM-06 ANGA-315MN-06 ANGA-315LL-06 ANGA-315LM-06 ANGA-315LM-062) ANGA-355LB-06 1PS00951PS00981PS01061PS01131PS01311PS01331PS01351PS01631PS01661PS01861PS02061PS02081PS02231PS02531PS02801PS02831PS03111PS03131PS03141PS03151PS03161PS03171PS03171PS0356- Price for 1 unit for IM B3 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CB3 -0CB2 1.800,– 1.940,– 2.260,– 2.800,– 3.190,– 3.650,– 3.850,– 3.990,– 4.510,– 5.470,– 5.880,– 6.370,– 8.450,– 9.870,– 13.000,– 14.700,– 18.100,– 20.600,– 22.700,– 25.100,– 30.200,– 37.100,– 42.600,– 46.700,– Discount level A Frame size LOHER VARIO 280 355 L 315 355 L 355 355 L 400 355 L 400 400 L 450 400 L 500 400 L 560 450 L 630 450 L 710 450 L 800 450 L 900 500 L 1000 500 L 1120 500 L 315 355 400 450 450 500 560 630 710 800 900 1000 1120 1250 IE2 IE2 IE2 ANSA-355LC-06 ANSA-355LD-06 ANSA-355LN-06 ANSA-355LN-06 ANSA-400LL-06 ANSA-400LN-06 ANSA-400LN-06 ANSA-450LL-06 ANSA-450LL-06 ANSA-450LN-06 ANSA-450LN-06 ANSA-500LL-06 ANSA-500LN-06 ANSA-500LN-06 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) Operating modes Mains-fed operation Converter-fed operation, standard insulation Converter-fed operation with special insulation (derating approx. 5 %) Mains-fed operation, pre-formed coil Converter-fed operation, pre-formed coil Voltages 690 VD, 50Hz 230 V/400 V, 50 Hz 500 VY, 50 Hz 500 VD, 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 IM V1, without canopy For other types of construction see options list 1PS03571PS03581PS03571PS03581PS04041PS04051PS04071PS04531PS04551PS04571PS04581PS05051PS05071PS0508- BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 45.000,– 50.900,– 55.200,– 58.100,– 64.100,– 67.900,– 74.600,– 80.400,– 86.000,– 94.000,– 106.000,– 117.000,– 129.000,– 136.000,– Frame size 90 ... 450 90 ... 450 160 ... 500 0 1 2 Order code - 500 450 ... 500 3 4 - 355 ... 500 90 ... 112 90 ... 315 355 ... 450 90 ... 400 90 ... 400 90 ... 500 90 ... 500 90 ... 315 90 ... 112 90 ... 112 90 ... 450 90 ... 500 90 … 355 90 ... 500 1) Outside the IE code classification according to IEC60034-30. 2) Motor with special rotor (Cu). … 0 1 3 5 6 8 9 0 1 2 3 4 6 8 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 69 … Discount level C Price for 1 unit for IM B3, 50Hz, mains operation Options acc. surcharge price list 1PS0… Prated 50Hz LOHER CHEMSTAR and VARIO 1PS0 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 60Hz kW FS kW IE class 8-pole: 750 rpm at 50Hz LOHER CHEMSTAR 1) 0,37 90 L a.A. 1) 0,55 90 L a.A. 1) 0,75 100 L a.A. 1) 1,1 100 L a.A. 1) 1,5 112 M a.A. 1) 2,2 132 S a.A. 1) 3 132 M a.A. 1) 4 160 M a.A. 1) 5,5 160 M a.A. 1) 7,5 160 L a.A. 1) 11 180 L a.A. 1) 15 200 L a.A. 1) 18,5 225 S a.A. 1) 22 225 M a.A. 1) 30 250 M a.A. 1) 37 280 S a.A. 1) 45 280 M a.A. 1) 55 315 S a.A. 1) 75 315 M a.A. 1) 90 315 M a.A. 1) 110 315 M a.A. 1) 132 315 L a.A. 1) 160 315 L a.A. 1) 200 355 L a.A. Motor type Article No. ANGA-090LR-08 ANGA-090LS-08 ANGA-100LR-08 ANGA-100LS-08 ANGA-112MS-08 ANGA-132SR-08 ANGA-132MR-08 ANGA-160MR-08 ANGA-160MS-08 ANGA-160LS-08 ANGA-180LS-08 ANGA-200LS-08 ANGA-225SR-08 ANGA-225MS-08 ANGA-250MM-08 ANGA-280SL-08 ANGA-280MM-08 ANGA-315SL-08 ANGA-315ML-08 ANGA-315MM-08 ANGA-315MN-08 2) ANGA-315LL-08 ANGA-315LM-08 3) ANGA-355LB-08 3) 1PS00951PS00981PS01061PS01081PS01131PS01311PS01331PS01631PS01651PS01661PS01861PS02061PS02201PS02231PS02531PS02801PS02831PS03111PS03131PS03141PS03151PS03161PS03171PS0356- Price for 1 unit for IM B3 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DA3 -0DB3 -0DB0 2.220,– 2.340,– 2.400,– 2.620,– 3.050,– 3.460,– 3.970,– 4.720,– 5.230,– 5.250,– 5.710,– 6.940,– 7.890,– 8.750,– 10.100,– 13.000,– 15.100,– 17.800,– 20.900,– 24.800,– 30.100,– 37.500,– 47.100,– 57.000,– Discount level A Frame size LOHER VARIO 225 355 L 250 355 L 280 355 L 315 355 L 355 400 L 400 400 L 450 400 L 500 450 L 560 450 L 630 450 L 670 450 L 710 500 L 800 500 L 900 500 L 950 500 L 250 280 315 355 400 450 500 560 630 710 750 800 900 1000 1050 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) ANSA-355LC-08 ANSA-355LD-08 ANSA-355LN-08 ANSA-355LX-08 ANSA-400LL-08 ANSA-400LN-08 ANSA-400LX-08 ANSA-450LL-08 ANSA-450LN-08 ANSA-450LN-08 ANSA-450LX-08 ANSA-500LL-08 ANSA-500LL-08 ANSA-500LN-08 ANSA-500LX-08 1PS03571PS03581PS03571PS03581PS04041PS04071PS04081PS04551PS04571PS04581PS04501PS05041PS05051PS05071PS0508- Operating modes Frame size Mains-fed operation 90 ... 450 Converter-fed operation, standard insulation 90 ... 450 Converter-fed operation with special insulation 160 ... 500 (derating approx. 5 %) Mains-fed operation, pre-formed coil 500 Converter-fed operation, pre-formed coil 500 Voltages 690 VD, 50Hz 355 ... 500 230 V/400 V, 50 Hz 90 ... 112 500 VY, 50 Hz 90 ... 315 500 VD, 50 Hz 355 ... 450 400 V/690 V, 50 Hz 90 ... 400 690 VY, 50 Hz 90 ... 400 For other voltages see options list 90 ... 500 Types of construction IM B3 90 ... 500 IM B5 90 ... 315 IM B34 90 ... 112 IM B14 90 ... 112 IM V1/canopy 90 ... 450 IM B35 90 ... 500 IM V1, without canopy 90 … 355 For other types of construction see options list 90 ... 500 1) Outside the IE code classification according to IEC60034-30. 2) Rated output, partial utilization up to 155°C (F). 3) Motor with special rotor (Cu). BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ Order code - 3 4 … 0 1 2 3 4 6 8 9 70 46.400,– 49.400,– 58.500,– 64.500,– 70.000,– 76.800,– 82.700,– 88.500,– 94.200,– 98.700,– 105.000,– 120.000,– 126.000,– 137.000,– 142.000,– 0 1 2 0 1 3 5 6 8 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 … Discount level C Price for 1 unit for IM B3, 50Hz, mains operation Options acc. surcharge price list 1PS0… Prated 50Hz LOHER CHEMSTAR and VARIO 1PS0 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 60Hz kW FS kW IE class 10-pole: 600 rpm at 50Hz LOHER CHEMSTAR 1) 0,55 100 L a.A. 1) 0,75 100 L a.A. 1) 1,1 112 M a.A. 1) 1,5 132 S a.A. 1) 2,2 132 M a.A. 1) 3 160 M a.A. 1) 4 160 M a.A. 1) 5,5 160 L a.A. 1) 7,5 180 L a.A. 1) 11 200 L a.A. 1) 15 225 S a.A. 1) 18,5 225 M a.A. 1) 22 250 M a.A. 1) 30 280 S a.A. 1) 37 280 M a.A. 1) 45 315 S a.A. 1) 55 315 M a.A. 1) 75 315 M a.A. 1) 90 315 L a.A. 1) 110 315 L a.A. 1) 132 355 M a.A. 1) 160 355 L a.A. Motor type Article No. ANGA-100L_-10 ANGA-100L_-10 ANGA-112M_-10 ANGA-132S_-10 ANGA-132M_-10 ANGA-160M_-10 ANGA-160M_-10 ANGA-160L_-10 ANGA-180LS-10 ANGA-200LR-10 ANGA-225SR-10 ANGA-225MS-10 ANGA-250MM-10 ANGA-280SL-10 ANGA-280MM-10 ANGA-315SL-10 ANGA-315ML-10 ANGA-315MN-10 ANGA-315LL-10 ANGA-315LM-10 ANGA-355MD-10 ANGA-355LB-10 1PS01061PS01081PS01131PS01311PS01331PS01631PS01651PS01661PS01861PS02061PS02201PS02231PS02531PS02801PS02831PS03111PS03131PS03151PS03161PS03171PS03551PS0356- Price for 1 unit for IM B3 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -0EA3 -0EA3 -0EA3 -0EA3 -0EA3 -0EA3 -0EA3 -0EA3 -0EA3 -0EA3 -0EA3 -0EA3 -0EA3 -0EA3 -0EA3 -0EA3 -0EA3 -0EA3 -0EA3 -0EA3 -0EA0 -0EA0 2.640,– 2.880,– 3.350,– 3.810,– 4.370,– 5.190,– 5.750,– 5.770,– 6.280,– 7.630,– 8.670,– 9.630,– 11.100,– 14.300,– 16.600,– 19.600,– 23.000,– 27.300,– 33.200,– 41.200,– 51.800,– 62.700,– LOHER VARIO 180 355 L 200 355 L 225 355 L 250 400 L 280 400 L 315 400 L 355 400 L 400 450 L 450 450 L 500 450 L 520 450 L 560 500 L 630 500 L 670 500 L 750 500 L 200 225 250 280 315 355 400 450 500 560 585 630 710 750 800 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) ANSA-355LC-10 ANSA-355LD-10 ANSA-355LX-10 ANSA-400LL-10 ANSA-400LN-10 ANSA-400LN-10 ANSA-400LX-10 ANSA-450LL-10 ANSA-450LN-10 ANSA-450LN-10 ANSA-450LX-10 ANSA-500LL-10 ANSA-500LN-10 ANSA-500LN-10 ANSA-500LX-10 1PS03571PS03581PS03581PS04041PS04051PS04071PS04081PS04541PS04551PS04571PS04581PS05041PS05051PS05071PS0508- Operating modes Frame size Mains-fed operation 100 ... 450 Converter-fed operation, standard insulation 100 ... 450 Converter-fed operation with special insulation 160 ... 500 (derating approx. 5 %) 450 ... 500 Mains-fed operation, pre-formed coil Converter-fed operation, pre-formed coil 450 ... 500 Voltages 690 VD, 50 Hz 355 ... 500 230 V/400 V, 50 Hz 100 ... 112 500 VY, 50 Hz 100 ... 315 500 VD, 50 Hz 355 ... 450 400 V/690 V, 50 Hz 100 ... 400 690 VY, 50 Hz 100 ... 400 For other voltages see options list 100 ... 500 Types of construction IM B3 100 ... 500 IM B5 100 ... 315 IM B34 100 ... 112 IM B14 100 ... 112 IM V1/canopy 100 ... 450 IM B35 100 ... 500 IM V1, without canopy 100 … 355 For other types of construction see options list 100 ... 500 1) Outside the IE code classification according to IEC60034-30. BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ Order code - 3 4 … 0 1 2 3 4 6 8 9 71 47.800,– 50.900,– 60.400,– 66.500,– 72.200,– 79.300,– 85.300,– 91.300,– 97.200,– 102.000,– 108.000,– 124.000,– 131.000,– 141.000,– 147.000,– 0 1 2 0 1 3 5 6 8 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. -0EA0 -0EA0 -0EA0 -0EA0 -0EA0 -0EA0 -0EA0 -0EA0 -0EA0 -0EA0 -0EA0 -0EA0 -0EA0 -0EA0 -0EA0 … Discount level C Price for 1 unit for IM B3, 50Hz, mains operation Options acc. surcharge price list 1PS0… Frame size Discount level A Prated 50Hz LOHER CHEMSTAR and VARIO 1PS0 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 60Hz kW FS kW IE class 12-pole: 500 rpm at 50Hz LOHER CHEMSTAR 1) 0,37 100 L a.A. 1) 0,55 100 L a.A. 1) 0,75 112 M a.A. 1) 1,1 132 S a.A. 1) 1,5 132 M a.A. 1) 2,2 160 M a.A. 1) 3 160 M a.A. 1) 4 160 L a.A. 1) 5,5 180 L a.A. 1) 7,5 200 L a.A. 1) 11 225 S a.A. 1) 15 225 M a.A. 1) 18,5 250 M a.A. 1) 22 280 S a.A. 1) 30 280 M a.A. 1) 37 315 S a.A. 1) 45 315 M a.A. 1) 55 315 M a.A. 1) 75 315 L a.A. 1) 90 315 L a.A. 1) 110 355 M a.A. 1) 140 355 L a.A. Motor type Article No. ANGA-100L_-12 ANGA-100L_-12 ANGA-112M_-122) ANGA-132S_-12 ANGA-132M_-12 ANGA-160M_-12 ANGA-160M_-12 ANGA-160L_-12 ANGA-180LS-12 ANGA-200LR-12 ANGA-225SR-12 ANGA-225MS-12 ANGA-250MM-12 ANGA-280SL-12 ANGA-280MM-12 ANGA-315SL-12 ANGA-315ML-12 ANGA-315MN-12 ANGA-315LL-12 ANGA-315LM-12 ANGA-355MD-12 ANGA-355LB-12 1PS01061PS01081PS01131PS01311PS01331PS01631PS01651PS01661PS01861PS02061PS02201PS02231PS02531PS02801PS02831PS03111PS03131PS03151PS03161PS03171PS03551PS0356- Price for 1 unit for IM B3 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD -0FA3 -0FA3 -0FA3 -0FA3 -0FA3 -0FA3 -0FA3 -0FA3 -0FA3 -0FA3 -0FA3 -0FA3 -0FA3 -0FA3 -0FA3 -0FA3 -0FA3 -0FA3 -0FA3 -0FA3 -0FA0 -0FA0 2.760,– 3.010,– 3.510,– 3.980,– 4.570,– 5.420,– 6.010,– 6.040,– 6.570,– 7.980,– 9.070,– 10.100,– 11.600,– 14.900,– 17.400,– 20.500,– 24.000,– 28.500,– 34.700,– 43.100,– 54.200,– 65.600,– LOHER VARIO 160 355 L 180 355 L 190 355 L 200 400 L 225 400 L 250 400 L 280 400 L 315 450 L 355 450 L 400 450 L 420 450 L 450 500 L 500 500 L 560 500 L 600 500 L 180 200 215 225 250 280 315 355 400 450 475 500 560 630 650 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) ANSA-355LC-12 ANSA-355LD-12 ANSA-355LX-12 ANSA-400LL-12 ANSA-400LN-12 ANSA-400LN-12 ANSA-400LX-12 ANSA-450LL-12 ANSA-450LN-12 ANSA-450LN-12 ANSA-450LX-12 ANSA-500LL-12 ANSA-500LN-12 ANSA-500LN-12 ANSA-500LX-12 1PS03571PS03581PS03581PS04041PS04051PS04071PS04081PS04541PS04551PS04571PS04581PS05041PS05051PS05071PS0508- Operating modes Frame size Mains-fed operation 100 ... 450 Converter-fed operation, standard insulation 100 ... 450 Converter-fed operation with special insulation 160 ... 500 (derating approx. 5 %) Mains-fed operation, pre-formed coil 450 ... 500 Converter-fed operation, pre-formed coil 450 ... 500 Voltages 690 VD, 50 Hz 355 ... 500 230 V/400 V, 50 Hz 100 ... 112 500 VY, 50 Hz 100 ... 315 500 VD, 50 Hz 355 ... 450 400 V/690 V, 50 Hz 100 ... 400 690 VY, 50 Hz 100 ... 400 For other voltages see options list 100 ... 500 Types of construction IM B3 100 ... 500 IM B5 100 ... 315 IM B34 100 ... 112 IM B14 100 ... 112 IM V1/canopy 100 ... 450 IM B35 100 ... 500 IM V1, without canopy 100 … 355 For other types of construction see options list 100 ... 500 1) Outside the IE code classification according to IEC60034-30. 2) BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ Order code - 3 4 … 0 1 2 3 4 6 8 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 72 49.400,– 52.400,– 62.200,– 68.500,– 74.500,– 81.700,– 87.900,– 94.000,– 100.000,– 104.000,– 112.000,– 126.000,– 135.000,– 141.000,– 149.000,– 0 1 2 0 1 3 5 6 8 9 Rated output, partial utilization up to 155°C (F). -0FA0 -0FA0 -0FA0 -0FA0 -0FA0 -0FA0 -0FA0 -0FA0 -0FA0 -0FA0 -0FA0 -0FA0 -0FA0 -0FA0 -0FA0 … Discount level C Price for 1 unit for IM B3, 50Hz, mains operation Options acc. surcharge price list 1PS0… Frame size Discount level A Prated 50Hz LOHER CHEMSTAR and VARIO 1PS0 motor series Motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 50Hz Frame size Prated 60Hz kW FS kW Motor type Article No. ANSA-355LC-14 ANSA-355LD-14 ANSA-400LL-14 ANSA-400LN-14 ANSA-400LN-14 ANSA-400LX-14 ANSA-450LL-14 ANSA-450LN-14 ANSA-450LN-14 ANSA-450LX-14 ANSA-500LL-14 ANSA-500LN-14 ANSA-500LN-14 ANSA-500LX-14 1PS03571PS03581PS04041PS04051PS04071PS04081PS04541PS04551PS04571PS04581PS05041PS05051PS05071PS0508- ANSA-355LC-16 ANSA-355LD-16 ANSA-400LL-16 ANSA-400LN-16 ANSA-400LX-16 ANSA-450LL-16 ANSA-450LN-16 ANSA-450LN-16 ANSA-450LX-16 ANSA-500LL-16 ANSA-500LN-16 ANSA-500LN-16 ANSA-500LX-16 1PS03571PS03581PS04051PS04071PS04081PS04541PS04551PS04571PS04581PS05041PS05051PS05071PS0508- Price for 1 unit for IM B3, 50Hz, mains operation LOHER VARIO 100 355 L 110 355 L 132 400 L 160 400 L 180 400 L 200 450 L 225 450 L 250 450 L 265 450 L 280 500 L 315 500 L 355 500 L 400 500 L 115 132 160 180 200 225 250 280 300 315 355 400 450 Operating modes Mains-fed operation Converter-fed operation, standard insulation Converter-fed operation with special insulation (derating approx. 5 %) Mains-fed operation, pre-formed coil Converter-fed operation, pre-formed coil Voltages 690 VD, 50 Hz 500 VD, 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM V1/canopy IM B35 For other types of construction see options list BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BH BH BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ BJ -0GA0 -0GA0 -0GA0 -0GA0 -0GA0 -0GA0 -0GA0 -0GA0 -0GA0 -0GA0 -0GA0 -0GA0 -0GA0 -0GA0 49.400,– 52.400,– 68.500,– 74.500,– 81.700,– 87.900,– 94.000,– 100.000,– 105.000,– 112.000,– 129.000,– 135.000,– 145.000,– 151.000,– -0HA0 -0HA0 -0HA0 -0HA0 -0HA0 -0HA0 -0HA0 -0HA0 -0HA0 -0HA0 -0HA0 -0HA0 -0HA0 54.100,– 61.500,– 76.700,– 84.300,– 90.600,– 96.900,– 103.000,– 107.000,– 115.000,– 132.000,– 139.000,– 150.000,– 156.000,– Frame size 355 ... 450 355 ... 450 355 ... 500 0 1 2 Order code - 355 ... 500 355 ... 500 3 4 - 355 ... 500 355 ... 450 355 ... 400 355 ... 400 355 ... 500 … 0 5 6 8 9 355 ... 500 355 ... 450 355 ... 500 355 ... 500 0 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 73 … Discount level C Discount level C LOHER VARIO 125 355 L 140 140 355 L 160 160 400 L 180 180 400 L 200 200 400 L 225 225 400 L 250 250 450 L 280 280 450 L 315 315 450 L 355 340 450 L 380 355 500 L 400 400 500 L 450 450 500 L 500 500 500 L 560 16-pole: 375 rpm at 50Hz LOHER CHEMSTAR on request Options acc. surcharge price list 1PS0… 14-pole: 430 rpm at 50Hz LOHER CHEMSTAR on request LOHER CHEMSTAR and VARIO 1PS0 motor series Pole-changing motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Mains-fed operation: double pole-changing for square-law load torque · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 60Hz kW FS kW Motor type Article No. 4-/2-pole: 1500/3000 rpm at 50Hz with 1 winding in Dahlander connection for fan drive LOHER CHEMSTAR 0,5/2 90 L a.A. AVGA-090LS-42 1PS00980,65/2,4 100 L a.A. AVGA-100LR-42 1PS01060,8/3 100 L a.A. AVGA-100LS-42 1PS01081,1/4,1 112 M a.A. AVGA-112MS-42 1PS01131,6/6 132 S a.A. AVGA-132SR-42 1PS01312,2/9 132 M a.A. AVGA-132MR-42 1PS01333/12 160 M a.A. AVGA-160M_-42 1PS01634/16 160 L a.A. AVGA-160L_-42 1PS01665,5/20 180 M a.A. AVGA-180MR-42 1PS01831) AVGA-180LS-42 1PS01866,3/25 180 L a.A. 8,5/33 200 L a.A. AVGA-200LS-42 1PS020610,5/38 225 S a.A. AVGA-225SR-42 1PS022013/46 225 M a.A. AVGA-225MS-42 1PS022315/55 250 M a.A. AVGA-250MM-42 1PS025320/75 280 S a.A. AVGA-280SL-42 1PS028024/90 280 M a.A. AVGA-280MM-42 1PS02832) AVGA-315SL-42 1PS031127/110 315 S a.A. 2) AVGA-315ML-42 1PS031333/132 315 M a.A. 2) AVGA-315MN-42 1PS031537/145 315 M a.A. 2) AVGA-315LL-42 1PS031644/172 315 L a.A. 2) AVGA-315LM-42 1PS031750/200 315 L a.A. 2) AVGA-355LB-42 1PS035665/250 355 L a.A. LOHER VARIO on request Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 230 V, 50 Hz 500 V, 50 Hz 400 V, 50 Hz 690 V, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 IM V1, without canopy For other types of construction see options list 1) Rated output, partial utilization up to 155°C (F). 2) Frame size 90 ... 355 90 ... 355 Price for 1 unit for IM B3 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND … 1 3 6 8 9 90 ... 355 90 ... 315 90 ... 112 90 ... 112 90 ... 355 90 ... 355 90 … 355 90 ... 355 0 1 2 3 4 6 8 9 Motor with special rotor (Cu). Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 74 2.730,– 2.970,– 3.110,– 3.390,– 3.800,– 4.280,– 4.980,– 5.890,– 6.250,– 6.750,– 8.190,– 9.620,– 11.000,– 12.700,– 16.700,– 18.900,– 22.700,– 25.900,– 30.600,– 36.500,– 44.400,– 55.300,– Order code - 0 1 90 ... 112 90 ... 315 90 ... 355 90 ... 355 90 ... 355 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NA3 -0NB0 … Discount level A Frame size Options acc. surcharge price list 1PS0… Prated 50Hz LOHER CHEMSTAR and VARIO 1PS0 motor series Pole-changing motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Mains-fed operation: double pole-changing for square-law load torque · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 60Hz kW FS kW Motor type 8-/4-pole: 750/1500 rpm at 50Hz with 1 winding in Dahlander connection for fan drive LOHER CHEMSTAR 0,35/1,3 90 L a.A. AVGA-090LS-84 1PS00980,45/2 100 L a.A. AVGA-100LR-84 1PS01060,55/2,5 100 L a.A. AVGA-100LS-84 1PS01080,9/3,7 112 M a.A. AVGA-112MS-84 1PS01131,3/5 132 S a.A. AVGA-132SR-84 1PS01311,7/6,8 132 M a.A. AVGA-132MR-84 1PS01333/10 160 M a.A. AVGA-160M_-84 1PS01633,5/13 160 L a.A. AVGA-160L_-84 1PS01664/16 180 M a.A. AVGA-180MR-84 1PS01835/20 180 L a.A. AVGA-180LS-84 1PS01867/28 200 L a.A. AVGA-200LR-84 1PS02068/33 225 S a.A. AVGA-225SR-84 1PS02201) AVGA-225S_-84 1PS02219,2/37 225 S a.A. 1) AVGA-225MS-84 1PS02239,5/39 225 M a.A. 1) AVGA-225M_-84 1PS022411/44 225 M a.A. 11/49 250 M a.A. AVGA-250MM-84 1PS025317/68 280 S a.A. AVGA-280SL-84 1PS028020/80 280 M a.A. AVGA-280MM-84 1PS028322/95 315 S a.A. AVGA-315SL-84 1PS031126/110 315 M a.A. AVGA-315ML-84 1PS031330/130 315 M a.A. AVGA-315MN-84 1PS031538/160 315 L a.A. AVGA-315LL-84 1PS031645/180 315 L a.A. AVGA-315LM-84 1PS03172) AVGA-355MB-84 1PS035350/220 355 M a.A. 2) AVGA-355LB-84 1PS035660/275 355 L a.A. LOHER VARIO on request Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 230 V, 50 Hz 500 V, 50 Hz 400 V, 50 Hz 690 V, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 IM V1, without canopy For other types of construction see options list 1) Rated output, partial utilization up to 155°C (F). 2) Price for 1 unit for IM B3 Article No. Frame size 90 ... 355 90 ... 355 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND … 1 3 6 8 9 90 ... 355 90 ... 315 90 ... 112 90 ... 112 90 ... 355 90 ... 355 90 … 355 90 ... 355 0 1 2 3 4 6 8 9 Motor with special rotor (Cu). Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 75 2.770,– 3.020,– 3.150,– 3.440,– 3.850,– 4.340,– 5.040,– 5.960,– 6.330,– 6.830,– 8.290,– 9.730,– 10.400,– 11.200,– 12.000,– 12.800,– 16.900,– 19.100,– 22.900,– 26.100,– 30.900,– 36.800,– 44.800,– 53.500,– 61.300,– Order code - 0 1 90 ... 112 90 ... 315 90 ... 355 90 ... 355 90 ... 355 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QA3 -0QB0 -0QB0 … Discount level A Frame size Options acc. surcharge price list 1PS0… Prated 50Hz LOHER CHEMSTAR and VARIO 1PS0 motor series Pole-changing motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Mains-fed operation: double pole-changing for square-law load torque · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 60Hz kW FS kW Motor type 6-/4-pole: 1000/1500 rpm at 50Hz with 2 separate windings for fan drive LOHER CHEMSTAR 0,4/1,3 90 L a.A. AVGA-090LS-64 0,6/1,8 100 L a.A. AVGA-100LR-64 0,75/2,4 100 L a.A. AVGA-100LS-64 0,9/3 112 M a.A. AVGA-112MS-64 1,25/4,2 132 S a.A. AVGA-132SR-64 1,65/5,5 132 M a.A. AVGA-132MR-64 2,2/7,5 160 M a.A. AVGA-160M_-64 3/9 160 M a.A. AVGA-160M_-64 3,5/12 160 L a.A. AVGA-160L_-64 4,5/14 180 M a.A. AVGA-180MR-64 5,5/16,5 180 L a.A. AVGA-180LS-64 7/20 200 L a.A. AVGA-200LR-64 9/26 200 L a.A. AVGA-200LS-64 10/31 225 S a.A. AVGA-225SR-64 13/38 225 M a.A. AVGA-225MS-64 17/48 250 M a.A. AVGA-250MM-64 25/70 280 S a.A. AVGA-280SL-64 30/82 280 M a.A. AVGA-280MM-64 32/95 315 S a.A. AVGA-315SL-64 37/115 315 M a.A. AVGA-315ML-64 47/135 315 M a.A. AVGA-315MN-64 1) AVGA-315LL-64 55/160 315 L a.A. 1)2) AVGA-315LM-64 75/200 315 L a.A. 90/250 355 L a.A. AVGA-355LB-64 LOHER VARIO on request Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 230 V, 50 Hz 500 V, 50 Hz 400 V, 50 Hz 690 V, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 IM V1, without canopy For other types of construction see options list 1) Rated output, partial utilization up to 155°C (F). 2) Price for 1 unit for IM B3 Article No. 1PS00981PS01061PS01081PS01131PS01311PS01331PS01631PS01651PS01661PS01831PS01861PS02061PS02081PS02201PS02231PS02531PS02801PS02831PS03111PS03131PS03151PS03161PS03171PS0356- Frame size 90 ... 355 90 ... 355 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND … 1 3 6 8 9 90 ... 355 90 ... 315 90 ... 112 90 ... 112 90 ... 355 90 ... 355 90 … 355 90 ... 355 0 1 2 3 4 6 8 9 Motor with special rotor (Cu). Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 76 2.830,– 3.080,– 3.220,– 3.520,– 3.940,– 4.440,– 5.160,– 5.630,– 6.100,– 6.540,– 7.060,– 7.770,– 8.480,– 9.960,– 11.400,– 13.100,– 17.300,– 19.600,– 23.500,– 26.800,– 31.700,– 37.800,– 45.900,– 57.800,– Order code - 0 1 90 ... 112 90 ... 315 90 ... 355 90 ... 355 90 ... 355 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA3 -0PA0 … Discount level A Frame size Options acc. surcharge price list 1PS0… Prated 50Hz LOHER CHEMSTAR and VARIO 1PS0 motor series Pole-changing motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Mains-fed operation: double pole-changing for square-law load torque · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 60Hz kW FS kW Motor type 8-/6-pole: 750/1000 rpm at 50Hz with 2 separate windings for fan drive LOHER CHEMSTAR 0,32/0,75 90 L a.A. AVGA-090LS-86 0,45/1 100 L a.A. AVGA-100LR-86 0,55/1,3 100 L a.A. AVGA-100LS-86 0,8/1,9 112 M a.A. AVGA-112MS-86 1,1/2,6 132 S a.A. AVGA-132SR-86 1,6/3,8 132 M a.A. AVGA-132MR-86 2,5/6 160 M a.A. AVGA-160M_-86 3,5/8 160 L a.A. AVGA-160L_-86 5,5/12,5 180 L a.A. AVGA-180LS-86 9,5/20 200 L a.A. AVGA-200LR-86 11/24 225 S a.A. AVGA-225SR-86 13/28 225 M a.A. AVGA-225MS-86 16/34 250 M a.A. AVGA-250MM-86 25/50 280 S a.A. AVGA-280SL-86 30/60 280 M a.A. AVGA-280MM-86 33/70 315 S a.A. AVGA-315SL-86 40/85 315 M a.A. AVGA-315ML-86 47/100 315 M a.A. AVGA-315MN-86 55/120 315 L a.A. AVGA-315LL-86 1)2) AVGA-315LM-86 70/150 315 L a.A. 85/190 355 L a.A. AVGA-355LB-86 LOHER VARIO on request Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 230 V, 50 Hz 500 V, 50 Hz 400 V, 50 Hz 690 V, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 IM V1, without canopy For other types of construction see options list 1) Rated output, partial utilization up to 155°C (F). 2) Article No. 1PS00981PS01061PS01081PS01131PS01311PS01331PS01631PS01661PS01861PS02061PS02201PS02231PS02531PS02801PS02831PS03111PS03131PS03151PS03161PS03171PS0356- Frame size 90 ... 355 90 ... 355 Price for 1 unit for IM B3 ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND … 1 3 6 8 9 90 ... 355 90 ... 315 90 ... 112 90 ... 112 90 ... 355 90 ... 355 90 … 355 90 ... 355 0 1 2 3 4 6 8 9 Motor with special rotor (Cu). Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications The prices are recommended without obligation Price list LOHER Motors 2015 Version a. 77 2.870,– 3.130,– 3.270,– 3.560,– 3.990,– 4.490,– 5.220,– 6.170,– 6.550,– 8.660,– 10.200,– 11.700,– 13.400,– 17.700,– 20.000,– 23.900,– 27.300,– 32.300,– 38.500,– 46.700,– 58.800,– Order code - 0 1 90 ... 112 90 ... 315 90 ... 355 90 ... 355 90 ... 355 -0RA3 -0RA3 -0RA3 -0RA3 -0RA3 -0RA3 -0RA3 -0RA3 -0RA3 -0RA3 -0RA3 -0RA3 -0RA3 -0RA3 -0RA3 -0RA3 -0RA3 -0RA3 -0RA3 -0RA3 -0RA0 … Options acc. surcharge price list 1PS0… Frame size Discount level A Prated 50Hz LOHER CHEMSTAR and VARIO 1PS0 motor series Pole-changing motors in cast-iron and steel versions · Cooling: self-ventilated (IC 411) · Mains-fed operation: triple pole-changing for constant load torque · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 60Hz kW FS kW Motor type Article No. Price for 1 unit for IM B3 8-/6-/4-pole: 750/1000/1500 rpm at 50Hz with 2 separate windings, thereof 1 winding in Dahlander connection LOHER CHEMSTAR 0,5/0,6/0,8 100 L a.A. ANGA-100LR-33 1PS0106- BD -0SA3 0,7/0,8/1,1 100 L a.A. ANGA-100LS-33 1PS0108- BD -0SA3 0,9/1,1/1,5 112 M a.A. ANGA-112MS-33 1PS0113- BD -0SA3 1,3/1,6/2,2 132 S a.A. ANGA-132SR-33 1PS0131- BD -0SA3 2,2/2,5/3,6 132 M a.A. ANGA-132MR-33 1PS0133- BD -0SA3 3,3/4/5,5 160 M a.A. ANGA-160M_-33 1PS0163- BD -0SA3 4,5/6/8 160 L a.A. ANGA-160L_-33 1PS0166- BD -0SA3 6/8/11 180 M a.A. ANGA-180MR-33 1PS0183- BD -0SA3 7/9/14 180 L a.A. ANGA-180LS-33 1PS0186- BD -0SA3 12/15/18,5 200 L a.A. ANGA-200LR-33 1PS0206- BD -0SA3 16/20/26 225 S a.A. ANGA-225SR-33 1PS0220- BD -0SA3 1) ANGA-225MS-33 1PS0223- BD -0SA3 19/22/30 225 M a.A. 24/28/36 250 M a.A. ANGA-250MM-33 1PS0253- BD -0SA3 31/37/50 280 S a.A. ANGA-280SL-33 1PS0280- BD -0SA3 37/45/60 280 M a.A. ANGA-280MM-33 1PS0283- BD -0SA3 2) ANGA-315SL-33 1PS0311- BD -0SA3 43/55/68 315 S a.A. 2) ANGA-315ML-33 1PS0313- BD -0SA3 50/65/80 315 M a.A. 2) ANGA-315MN-33 1PS0315- BD -0SA3 60/75/95 315 M a.A. 2) ANGA-315LL-33 1PS0316- BD -0SA3 70/90/110 315 L a.A. LOHER VARIO on request Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 230 V, 50 Hz 500 V, 50 Hz 400 V, 50 Hz 690 V, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 IM V1, without canopy For other types of construction see options list 1) Rated output, partial utilization up to 155°C (F). 2) Frame size 100 ... 315 100 ... 315 Order code - 0 1 100 ... 112 100 ... 315 100 ... 315 100 ... 315 100 ... 315 … 1 3 6 8 9 100 ... 315 100 ... 315 100 ... 112 100 ... 112 100 ... 315 100 ... 315 100 ... 315 100 ... 315 0 1 2 3 4 6 8 9 Motor with special rotor (Cu). Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications The prices are recommended without obligation Price list LOHER Motors 2015 Version a. 78 3.350,– 3.500,– 3.810,– 4.260,– 4.790,– 5.560,– 6.560,– 6.960,– 7.500,– 9.090,– 10.600,– 12.200,– 14.000,– 18.400,– 20.800,– 24.800,– 28.300,– 33.400,– 39.800,– … Discount level A Frame size Options acc. surcharge price list 1PS0… Prated 50Hz LOHER CHEMSTAR 1PS0 motor series Brake motors with High Efficiency IE2 in cast-iron versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE2, 0.75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % kW FS IE class kW 2-pole: 3000 rpm at 50Hz LOHER CHEMSTAR 5,5 132 S a.A. IE2 7,5 132 S a.A. IE2 11 160 M a.A. IE2 4-pole: 1500 rpm at 50Hz LOHER CHEMSTAR 5,5 132 S a.A. IE2 7,5 132 M a.A. IE2 11 160 M a.A. IE2 15 160 L a.A. IE2 18,5 180 M a.A. IE2 22 180 L a.A. IE2 30 200 L a.A. IE2 37 225 S a.A. IE2 45 225 M a.A. IE2 55 250 M a.A. IE2 6-pole: 1000 rpm at 50Hz LOHER CHEMSTAR 3 132 S a.A. IE2 4 132 M a.A. IE2 5,5 132 M a.A. IE2 7,5 160 M a.A. IE2 11 160 L a.A. IE2 15 180 L a.A. IE2 18,5 200 L a.A. IE2 22 200 L a.A. IE2 30 225 M a.A. IE2 37 250 M a.A. IE2 Motor type Article No. 80 80 150 ABGA-132SR-02 ABGA-132SS-02 ABGA-160MR-02 1PS01311PS01321PS0163- 80 150 150 260 260 260 400 400 400 400 ABGA-132SR-04 ABGA-132MS-04 ABGA-160MR-04 ABGA-160LR-04 ABGA-180MR-04 ABGA-180LS-04 ABGA-200LR-04 ABGA-225SR-04 ABGA-225MS-04 ABGA-250MM-04 1PS01311PS01331PS01631PS01661PS01831PS01861PS02061PS02201PS02231PS0253- 80 80 150 150 260 260 400 400 400 400 ABGA-132SR-06 ABGA-132MR-06 ABGA-132MS-06 ABGA-160MR-06 ABGA-160LS-06 ABGA-180LS-06 ABGA-200LR-06 ABGA-200LS-06 ABGA-225MS-06 ABGA-250MM-06 1PS01311PS01331PS01351PS01631PS01661PS01861PS02061PS02081PS02231PS0253- Braking torque Price for 1 unit for IM B3 Nm Operating modes Mains-fed operation Converter-fed operation, standard insulation Converter-fed operation with special insulation (derating approx. 5 %) Voltages 230 V/400 V, 50 Hz 500 VY, 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 IM V1, without canopy For other types of construction see options list Frame size 132 ... 250 132 ... 250 160 ... 250 RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD 0 1 2 3 4 6 8 9 Standard brake supply: 230 V, 1-phase AC Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 79 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 -0BA3 4.610,– 5.130,– 5.630,– 7.020,– 7.850,– 8.390,– 10.800,– 12.100,– 13.500,– 15.400,– -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 -0CA3 5.300,– 5.560,– 5.850,– 6.040,– 7.440,– 9.090,– 10.500,– 11.400,– 13.900,– 15.800,– … 1 3 6 8 9 132 ... 250 132 ... 250 132 ... 250 132 ... 250 132 ... 250 132 ... 250 132 ... 250 132 ... 250 4.780,– 5.320,– 5.720,– Order code - 0 1 2 132 ... 250 132 ... 250 132 ... 250 132 ... 250 132 ... 250 -0AA3 -0AA3 -0AA3 … Options acc. surcharge price list 1PS0… Frame Prated 60Hz size Discount level A Prated 50Hz LOHER CHEMSTAR and VARIO 1PS0 motor series Motors in cast-iron and steel versions · Cooling: water-cooled (IC71W) · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 60Hz kW FS kW IE class 2-pole: 3000 rpm at 50Hz LOHER CHEMSTAR 2) 55 200 D a.A. 2) 75 200 E a.A. 2) 90 200 E a.A. 2) 90 225 E a.A. 2) 120 225 E a.A. 2) 120 250 E a.A. 2) 132 250 E a.A. 2) 185 250 F a.A. 2) 220 250 G a.A. 2) 250 280 G a.A. 2) 280 280 J a.A. 2) 315 280 J a.A. 2) 355 280 J a.A. 3) 400 315 J a.A. 3) 500 315 J a.A. Motor type Article No. ANWA-200DG-02 ANWA-200EF-02 1) ANWA-200EF-02 ANWA-225EF-02 1) ANWA-225FF-02 ANWA-250EA-02 ANWA-250EF-02 1) ANWA-250FF-02 1) ANWA-250GF-02 1) ANWA-280GA-02 ANWA-280JA-021) ANWA-280JA-021) 1) ANWA-280JA-02 ANWA-315JE-021) 1) ANWA-315JE-02 1PS02021PS02031PS02041PS02231PS02241PS02521PS02531PS02541PS02551PS02841PS02851PS02861PS02871PS03161PS0317- Price for 1 unit for IM B3 BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX -0AA0 -0AA0 -0AB0 -0AA0 -0AB0 -0AA0 -0AA0 -0AB0 -0AB0 -0AB0 -0AB0 -0AB0 -0AB0 -0AB0 -0AB0 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. Discount level A Frame size LOHER VARIO 450 355 L 500 355 L 560 355 L 630 355 L 710 355 L 800 400 L 850 400 L 1000 400 L 1120 450 L 1250 450 L 500 560 630 710 800 900 1000 a.A. a.A. a.A. 3) ANWA-355LL-02 ANWA-355LL-02 ANWA-355LN-02 ANWA-355LN-02 ANWA-355LX-02 ANWA-400LN-02 ANWA-400LN-02 ANWA-400LX-02 ANWA-450LN-02 ANWA-450LN-02 3) 3) 3) 3) 3) 3) 3) 3) 3) Operating modes Mains-fed operation Converter-fed operation, standard insulation Converter-fed operation with special insulation (derating approx. 5 %) Voltages 690 VD, 50Hz 500 VY, 50 Hz 500 VD, 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM V1/canopy IM B35 For other types of construction see options list 1) Motor with special rotor (Cu). 1PS03531PS03541PS03551PS03571PS03581PS04051PS04071PS04081PS04571PS0458- Frame size 200 ... 450 200 ... 400 200 ... 450 Not according to EG 640/2009. Outside the IE code classification according to IEC60034-30. BW BW BW BW BW BW BW BW BW BW 80 55.500,– 56.900,– 58.300,– 59.800,– 65.000,– 69.200,– 78.400,– 86.200,– 97.000,– 105.000,– … 0 1 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. -0AA0 -0AA0 -0AA0 -0AA0 -0AA0 -0AA0 -0AA0 -0AA0 -0AA0 -0AA0 Order code - 0 3 5 6 8 9 200 ... 450 200 ... 315 200 ... 400 200 ... 450 200 ... 450 3) 0 1 2 355 ... 450 200 ... 315 355 ... 450 200 ... 400 200 ... 400 200 ... 450 2) … Discount level C Price for 1 unit for IM B3, 50Hz, mains operation Options acc. surcharge price list 1PS0… Prated 50Hz LOHER CHEMSTAR and VARIO 1PS0 motor series Motors in cast-iron and steel versions · Cooling: water-cooled (IC71W) · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 60Hz kW FS kW IE class 4-pole: 1500 rpm at 50Hz LOHER CHEMSTAR 2) 55 200 D a.A. 2) 75 200 E a.A. 2) 90 200 E a.A. 2) 90 225 E a.A. 2) 120 225 E a.A. 2) 120 250 E a.A. 2) 132 250 E a.A. 2) 185 250 F a.A. 2) 220 250 G a.A. 2) 250 280 G a.A. 2) 280 280 J a.A. 2) 315 280 J a.A. 2) 355 280 J a.A. 3) 400 315 J a.A. 3) 500 315 J a.A. Motor type Article No. ANWA-200EA-04 ANWA-200FA-04 1) ANWA-200FA-04 ANWA-225FA-04 1) ANWA-225GF-04 ANWA-250EA-04 ANWA-250FA-04 1) ANWA-250FF-04 1) ANWA-250GF-04 1) ANWA-280GF-04 ANWA-280JG-041) ANWA-280JG-041) 1) ANWA-280JG-04 ANWA-315JE-041) 1) ANWA-315PA-04 1PS02021PS02031PS02041PS02231PS02251PS02521PS02531PS02541PS02551PS02851PS02861PS02871PS02881PS03161PS0317- Price for 1 unit for IM B3 BX BX BX BX BX BX BX BX BX BX BX BX BX BX BX -0BA0 -0BA0 -0BB0 -0BA0 -0BB0 -0BA0 -0BA0 -0BB0 -0BB0 -0BB0 -0BB0 -0BB0 -0BB0 -0BB0 -0BB0 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. Discount level A Frame size LOHER VARIO 500 355 L 560 355 L 630 355 L 710 355 L 750 355 L 800 400 L 950 400 L 1050 400 L 1100 450 L 1200 450 L 1300 450 L 1400 500 L 1600 500 L 1700 500 L 1850 500 L 560 630 710 800 850 900 1050 1200 1300 1450 1500 a.A. a.A. a.A. a.A. 3) ANWA-355LL-04 ANWA-355LL-04 ANWA-355LN-04 ANWA-355LN-04 ANWA-355LX-04 ANWA-400LN-04 ANWA-400LN-04 ANWA-400LX-04 ANWA-450LL-04 ANWA-450LN-04 ANWA-450LN-04 ANWA-500LL-04 ANWA-500LL-04 ANWA-500LN-04 ANWA-500LN-04 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) Operating modes Mains-fed operation Converter-fed operation, standard insulation Converter-fed operation with special insulation (derating approx. 5 %) Mains-fed operation, pre-formed coil Voltages 690 VD, 50Hz 500 VY, 50 Hz 500 VD, 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM V1/canopy IM B35 For other types of construction see options list 1) Motor with special rotor (Cu). 1PS03531PS03541PS03551PS03571PS03581PS04051PS04071PS04081PS04551PS04571PS04581PS05041PS05051PS05071PS0508- BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 -0BA0 54.800,– 55.900,– 57.800,– 61.500,– 67.000,– 73.500,– 75.500,– 82.500,– 88.500,– 94.000,– 99.000,– 120.000,– 130.000,– 139.000,– 151.000,– Frame size 200 ... 450 200 ... 400 200 ... 500 0 1 2 Order code - 450 ... 500 3 - 355 ... 500 200 ... 315 355 ... 450 200 ... 400 200 ... 400 200 ... 500 200 ... 500 200 ... 315 200 ... 400 200 ... 500 200 ... 500 2) Not according to EG 640/2009. 3) Outside the IE code classification according to IEC60034-30. … 0 3 5 6 8 9 0 1 4 6 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 81 … Discount level C Price for 1 unit for IM B3, 50Hz, mains operation Options acc. surcharge price list 1PS0… Prated 50Hz LOHER CHEMSTAR and VARIO 1PS0 motor series Motors in cast-iron and steel versions · Cooling: water-cooled (IC71W) · Insulation: thermal class 155 (temperature class F), CHEMSTAR IP55 degree of protection, VARIO IP56 degree of protection utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 50Hz Frame size Prated 60Hz kW FS kW IE class Motor type Article No. ANWA-355LL-06 ANWA-355LL-06 ANWA-355LN-06 ANWA-355LN-06 ANWA-355LX-06 ANWA-400LN-06 ANWA-400LN-06 ANWA-400LX-06 ANWA-450LL-06 ANWA-450LN-06 ANWA-450LN-06 ANWA-500LL-06 ANWA-500LN-06 ANWA-500LN-06 1PS03531PS03541PS03571PS03581PS03501PS04051PS04071PS04081PS04551PS04571PS04581PS05051PS05071PS0508- ANWA-355LL-08 ANWA-355LL-08 ANWA-355LN-08 ANWA-355LN-08 ANWA-355LX-08 ANWA-400LN-08 ANWA-400LN-08 ANWA-400LX-08 ANWA-450LL-08 ANWA-450LN-08 ANWA-450LN-08 ANWA-450LX-08 ANWA-500LL-08 ANWA-500LL-08 ANWA-500LN-08 ANWA-500LX-08 1PS03531PS03541PS03551PS03571PS03581PS04051PS04071PS04081PS04541PS04551PS04571PS04501PS05041PS05051PS05071PS0508- Price for 1 unit for IM B3, 50Hz, mains operation LOHER VARIO 315 355 L 355 355 L 400 355 L 450 355 L 500 355 L 560 400 L 630 400 L 710 400 L 800 450 L 900 450 L 1000 450 L 1100 450 L 1120 500 L 1250 500 L 1400 500 L 1500 500 L 335 375 425 475 530 600 670 750 850 950 1060 1150 1200 1325 1500 1600 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) 1) Operating modes Frame size Mains-fed operation 200 ... 450 Converter-fed operation, standard insulation 200 ... 400 Converter-fed operation with special insulation 200 ... 500 (derating approx. 5 %) Mains-fed operation, pre-formed coil 450 ... 500 Voltages 690 VD, 50Hz 355 ... 500 500 VY, 50 Hz 200 ... 315 500 VD, 50 Hz 355 ... 450 400 V/690 V, 50 Hz 200 ... 400 690 VY, 50 Hz 200 ... 400 For other voltages see options list 200 ... 500 Types of construction IM B3 200 ... 500 IM B5 200 ... 315 IM V1/canopy 200 ... 450 IM B35 200 ... 500 For other types of construction see options list 200 ... 500 1) Outside the IE code classification according to IEC60034-30. BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW BW -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 -0DA0 60.800,– 62.900,– 65.800,– 68.200,– 69.700,– 76.400,– 82.800,– 88.600,– 94.100,– 102.000,– 114.000,– 121.000,– 134.000,– 144.000,– 152.000,– 158.000,– Order code - 3 … 0 1 4 6 9 82 58.500,– 59.900,– 62.500,– 65.900,– 69.000,– 74.400,– 79.000,– 84.000,– 91.000,– 97.000,– 104.000,– 132.000,– 140.000,– 155.000,– 0 1 2 0 3 5 6 8 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 -0CA0 … Discount level C Discount level C LOHER VARIO 1) 450 355 L 500 1) 500 355 L 560 1) 560 355 L 630 1) 630 355 L 710 1) 710 355 L 800 1) 800 400 L 900 1) 900 400 L 1000 1) 1000 400 L 1100 1) 1120 450 L 1200 1) 1200 450 L 1300 1) 1300 450 L 1400 1) 1400 500 L 1600 1) 1600 500 L 1700 1) 1800 500 L 1900 8-pole: 750 rpm at 50Hz LOHER CHEMSTAR on request Options acc. surcharge price list 1PS0… 6-pole: 1000 rpm at 50Hz LOHER CHEMSTAR on request LOHER CHEMSTAR 1PS0 motor series IE3 Motors in cast-iron versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE3, 0.75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 50Hz Frame Prated 60Hz size kW FS IE class Motor type Article No. ANGA-090LS-02 ANGA-090LT-02 ANGA-100LT-02 ANGA-112MT-02 ANGA-132SS-02 ANGA-132ST-02 ANGA-160MS-02 ANGA-160MT-02 ANGA-160LT-02 ANGA-180MT-02 ANGA-200LS-02 ANGA-200LT-02 ANGA-225MT-02 ANGA-250MN-02 ANGA-280SM-02 ANGA-280MN-02 ANGA-315SL-02 ANGA-315ML-02 ANGA-315MN-02 ANGA-315LL-02 ANGA-315LN-02 1PS00951PS00981PS01061PS01131PS01311PS01321PS01631PS01651PS01661PS01831PS02061PS02081PS02231PS02531PS02801PS02831PS03111PS03131PS03151PS03161PS0318- Price for 1 unit for IM B3 Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 690 VD, 50Hz 230 V/400 V, 50 Hz 500 VY, 50 Hz 500 VD, 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 IM V1, without canopy For other types of construction see options list Frame size 90 ... 315 90 ... 315 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD … 0 1 3 5 6 8 9 90 ... 315 90 ... 315 90 ... 112 90 ... 112 90 ... 315 90 ... 315 90 ... 315 90 ... 315 0 1 2 3 4 6 8 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 83 2.190,– 2.380,– 2.560,– 2.810,– 3.210,– 3.600,– 4.330,– 5.030,– 5.340,– 5.870,– 7.180,– 8.290,– 9.600,– 11.000,– 14.500,– 16.400,– 19.700,– 22.600,– 26.800,– 32.100,– 39.300,– Order code - 0 1 90 ... 315 90 ... 280 90 ... 315 90 ... 315 90 ... 315 90 ... 315 90 ... 315 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 -0AH3 … Options acc. surcharge price list 1PS0… Discount level A kW 2-pole: 3000 rpm at 50Hz LOHER CHEMSTAR 1,5 90 L 1,5 IE3 2,2 90 L 2,2 IE3 3 100 L 3 IE3 4 112 M 4 IE3 5,5 132 S 5,5 IE3 7,5 132 S 7,5 IE3 11 160 M 11 IE3 15 160 M 15 IE3 18,5 160 L 18,5 IE3 22 180 M 22 IE3 30 200 L 30 IE3 37 200 L 37 IE3 45 225 M 45 IE3 55 250 M 55 IE3 75 280 S 75 IE3 90 280 M 90 IE3 110 315 S 110 IE3 132 315 M 132 IE3 160 315 M 160 IE3 200 315 L 200 IE3 250 315 L 250 IE3 LOHER CHEMSTAR 1PS0 motor series IE3 Motors in cast-iron versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE3, 0.75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 50Hz Frame Prated 60Hz size kW FS IE class Motor type Article No. ANGA-090LS-04 ANGA-090LT-04 ANGA-100LS-04 ANGA-100LT-04 ANGA-112MT-04 ANGA-132ST-04 ANGA-132MT-04 ANGA-160MS-04 ANGA-160LT-04 ANGA-180MS-04 ANGA-180LT-04 ANGA-200LT-04 ANGA-225SS-04 ANGA-225MT-04 ANGA-250MN-04 ANGA-280SM-04 ANGA-280MN-04 ANGA-315SL-04 ANGA-315ML-04 ANGA-315MN-04 ANGA-315LL-04 ANGA-315LM-04 1PS00951PS00981PS01061PS01081PS01131PS01311PS01331PS01631PS01661PS01831PS01861PS02061PS02201PS02231PS02531PS02801PS02831PS03111PS03131PS03151PS03161PS0317- Price for 1 unit for IM B3 Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 690 VD, 50Hz 230 V/400 V, 50 Hz 500 VY, 50 Hz 500 VD, 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 IM V1, without canopy For other types of construction see options list Frame size 90 ... 315 90 ... 315 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD … 0 1 3 5 6 8 9 90 ... 315 90 ... 315 90 ... 112 90 ... 112 90 ... 315 90 ... 315 90 ... 315 90 ... 315 0 1 2 3 4 6 8 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 84 2.010,– 2.130,– 2.380,– 2.490,– 2.740,– 3.140,– 3.500,– 4.220,– 4.890,– 5.310,– 5.710,– 6.950,– 8.170,– 9.300,– 10.700,– 14.100,– 15.900,– 19.000,– 21.800,– 25.700,– 30.700,– 37.400,– Order code - 0 1 90 ... 315 90 ... 280 90 ... 315 90 ... 315 90 ... 315 90 ... 315 90 ... 315 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 … Options acc. surcharge price list 1PS0… Discount level A kW 4-pole: 1500 rpm at 50Hz LOHER CHEMSTAR 1,1 90 L 1,1 IE3 1,5 90 L 1,5 IE3 2,2 100 L 2,2 IE3 3 100 L 3 IE3 4 112 M 4 IE3 5,5 132 S 5,5 IE3 7,5 132 M 7,5 IE3 11 160 M 11 IE3 15 160 L 15 IE3 18,5 180 M 18,5 IE3 22 180 L 22 IE3 30 200 L 30 IE3 37 225 S 37 IE3 45 225 M 45 IE3 55 250 M 55 IE3 75 280 S 75 IE3 90 280 M 90 IE3 110 315 S 110 IE3 132 315 M 132 IE3 160 315 M 160 IE3 200 315 L 200 IE3 250 315 L 250 IE3 LOHER CHEMSTAR 1PS0 motor series IE3 Motors in cast-iron versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE3, 0.75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % Prated 50Hz Frame Prated 60Hz size kW FS IE class Motor type Article No. ANGA-090LS-06 ANGA-100LS-06 ANGA-100LT-06 ANGA-112MT-06 ANGA-132SS-06 ANGA-132MS-06 ANGA-132MT-06 ANGA-160MS-06 ANGA-160LT-06 ANGA-180LT-06 ANGA-200LS-06 ANGA-200LT-06 ANGA-225MT-06 ANGA-250MN-06 ANGA-280SM-06 ANGA-280MN-06 ANGA-315SL-06 ANGA-315ML-06 ANGA-315MM-06 ANGA-315LK-06 ANGA-315LL-06 ANGA-315LM-06 1PS00951PS01051PS01061PS01131PS01311PS01331PS01351PS01631PS01661PS01861PS02061PS02081PS02231PS02531PS02801PS02831PS03111PS03131PS03141PS03151PS03161PS0317- Price for 1 unit for IM B3 Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 690 VD, 50Hz 230 V/400 V, 50 Hz 500 VY, 50 Hz 500 VD, 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 IM V1, without canopy For other types of construction see options list Frame size 90 ... 315 90 ... 315 BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD BD … 0 1 3 5 6 8 9 90 ... 315 90 ... 315 90 ... 112 90 ... 112 90 ... 315 90 ... 315 90 ... 315 90 ... 315 0 1 2 3 4 6 8 9 Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 85 2.110,– 2.360,– 2.630,– 3.210,– 3.690,– 4.150,– 4.350,– 4.690,– 5.210,– 6.280,– 6.820,– 7.310,– 9.500,– 11.000,– 14.300,– 16.000,– 19.500,– 22.000,– 24.100,– 26.500,– 31.600,– 38.500,– Order code - 0 1 90 ... 315 90 ... 280 90 ... 315 90 ... 315 90 ... 315 90 ... 315 90 ... 315 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 … Options acc. surcharge price list 1PS0… Discount level A kW 6-pole: 1000 rpm at 50Hz LOHER CHEMSTAR 0,75 90 L 0,75 IE3 1,1 100 L 1,1 IE3 1,5 100 L 1,5 IE3 2,2 112 M 2,2 IE3 3 132 S 3 IE3 4 132 M 4 IE3 5,5 132 M 5,5 IE3 7,5 160 M 7,5 IE3 11 160 L 11 IE3 15 180 L 15 IE3 18,5 200 L 18,5 IE3 22 200 L 22 IE3 30 225 M 30 IE3 37 250 M 37 IE3 45 280 S 45 IE3 55 280 M 55 IE3 75 315 S 75 IE3 90 315 M 90 IE3 110 315 M 110 IE3 132 315 L 132 IE3 160 315 L 160 IE3 200 315 L 200 IE3 LOHER CHEMSTAR 1PS0 motor series IE3 Brake motors with High Efficiency IE3 in cast-iron versions · Cooling: self-ventilated (IC 411) · Efficiency: High Efficiency IE3, 0.75 kW and above in accordance with IEC 60034-30 · Insulation: thermal class 155 (temperature class F), IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B), S1-100 % kW FS IE class kW 2-pole: 3000 rpm at 50Hz LOHER CHEMSTAR 5,5 132 S 5,5 IE3 7,5 132 S 7,5 IE3 11 160 M 11 IE3 4-pole: 1500 rpm at 50Hz LOHER CHEMSTAR 5,5 132 S 5,5 IE3 7,5 132 M 7,5 IE3 11 160 M 11 IE3 15 160 L 15 IE3 18,5 180 M 18,5 IE3 22 180 L 22 IE3 30 200 L 30 IE3 37 225 S 37 IE3 45 225 M 45 IE3 55 250 M 55 IE3 6-pole: 1000 rpm at 50Hz LOHER CHEMSTAR 3 132 S 3 IE3 4 132 M 4 IE3 5,5 132 M 5,5 IE3 7,5 160 M 7,5 IE3 11 160 L 11 IE3 15 180 L 15 IE3 18,5 200 L 18,5 IE3 22 200 L 22 IE3 30 225 M 30 IE3 37 250 M 37 IE3 Motor type Article No. 80 80 150 ABGA-132SS-02 ABGA-132ST-02 ABGA-160MS-02 1PS01311PS01321PS0163- 80 150 150 260 260 260 400 400 400 400 ABGA-132ST-04 ABGA-132MT-04 ABGA-160MS-04 ABGA-160LT-04 ABGA-180MS-04 ABGA-180LT-04 ABGA-200LT-04 ABGA-225SS-04 ABGA-225MT-04 ABGA-250MN-04 1PS01311PS01331PS01631PS01661PS01831PS01861PS02061PS02201PS02231PS0253- 80 80 150 150 260 260 400 400 400 400 ABGA-132SS-06 ABGA-132MS-06 ABGA-132MT-06 ABGA-160MS-06 ABGA-160LT-06 ABGA-180LT-06 ABGA-200LS-06 ABGA-200LT-06 ABGA-225MT-06 ABGA-250MN-06 1PS01311PS01331PS01351PS01631PS01661PS01861PS02061PS02081PS02231PS0253- Braking torque Price for 1 unit for IM B3 Nm Operating modes Mains-fed operation Converter-fed operation, standard insulation Voltages 230 V/400 V, 50 Hz 500 VY, 50 Hz 400 V/690 V, 50 Hz 690 VY, 50 Hz For other voltages see options list Types of construction IM B3 IM B5 IM B34 IM B14 IM V1/canopy IM B35 IM V1, without canopy For other types of construction see options list Frame size 132 ... 250 132 ... 250 RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD 0 1 2 3 4 6 8 9 Standard brake supply: 230 V, 1-phase AC Higher outputs, other voltages and frequencies on request. Subject to availability and technical modifications. The prices are recommended without obligation. Price list LOHER Motors 2015 Version a. 86 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 -0BH3 5.110,– 5.630,– 6.330,– 7.720,– 8.660,– 9.200,– 11.700,– 13.100,– 14.500,– 16.500,– -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 -0CH3 5.800,– 6.060,– 6.350,– 6.740,– 8.140,– 9.900,– 11.400,– 12.300,– 14.900,– 16.900,– … 1 3 6 8 9 132 ... 250 132 ... 250 132 ... 250 132 ... 180 132 ... 250 132 ... 250 132 ... 250 132 ... 250 5.280,– 5.820,– 6.420,– Order code - 0 1 132 ... 250 132 ... 250 132 ... 250 132 ... 250 132 ... 250 -0AH3 -0AH3 -0AH3 … Options acc. surcharge price list 1PS0… Frame Prated 60Hz size Discount level A Prated 50Hz LOHER CHEMSTAR and VARIO 1PS0 motor series Article No. supplements Selection and ordering data Voltages Voltage Additional Motor series code identification LOHER CHEMSTAR 11th position code with of the order code Article No. and plain text if required 1PS0. . . - . . . .-.... LOHER VARIO Surcharge / List price EURO Discount level A Discount level C Frame size 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Optional voltages 690 V D, 50Hz 0 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 230 V D / 400 V S, 50Hz 1 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N N N 500 V S, 50Hz 3 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N 400 V D, 50Hz 4 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 500 V D, 50Hz 5 87,– 107,– 130,– o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 400 V D / 690 V S, 50Hz 6 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 690 V S, 50Hz 1) 415 V S, 50Hz o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N 9 L1C 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 415 V D, 50Hz 1) 9 L1D 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– o.MP. o.MP. o.MP. o.MP. 8 1) 9 L1L 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 220 V D / 380 V S, 50Hz 1) 9 L1R 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– N N N N N N 1000 V D, 50 Hz 1) 9 9 L1V L1Y ● and identification code 87,– 87,– 107,– 107,– 130,– 130,– 165,– 165,– 206,– 206,– 265,– 265,– 323,– 323,– 478,– 478,– 603,– 603,– 772,– 772,– 1.000,– 1.000,– 1.210,– 1.210,– N a.A. N a.A. N a.A. N a.A. 220 V D / 380 V S, 60Hz (50Hz-output) 1) 9 L2A 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– N N N N N N 220 V D / 380 V S, 60Hz (60Hz-output) 1) 9 L2B 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– N N N N N N 380 V D / 660 V S, 60Hz (50Hz-output) 1) 9 L2C 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– N N N N N N 380 V D / 660 V S, 60Hz (60Hz-output) 1) 9 L2D 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– N N N N N 460 V S, 60Hz (60Hz-output) 1) 9 L2E 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 460 V D, 60Hz (60Hz-output) 1) 9 L2F 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– 575 V S, 60Hz (60Hz-output) 1) 9 L2L 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N 575 V D, 60Hz (60Hz-output) 1) 9 L2M 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– 440 V S, 60Hz (50Hz-output) 1) 9 L2Q 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 440 V D, 60Hz (50Hz-output) 1) 9 L2R 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 460 V S, 60Hz (50Hz-output) 1) 9 L2S 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 460 V D, 60Hz (50Hz-output) 1) 9 L2T 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 575 V S, 60Hz (50Hz-output) 1) 9 L2U 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 575 V D, 60Hz (50Hz-output) 1) 9 L2V 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 440 V S, 60Hz (60Hz-output) 1) 9 L2W 43,– 54,– 65,– 83,– 102,– 132,– 152,– 213,– 243,– 314,– 408,– 530,– N N N N 440 V D, 60Hz (60Hz-output) 1) 9 9 L2X L2Y ● and identification code 43,– N 54,– N 65,– N 83,– N 102,– N 132,– N 152,– N 213,– N 243,– N 314,– N 408,– N 530,– N see PMD a.A. a.A. a.A. 380 V D / 660 V S, 50Hz Other voltages 1) Other voltages 60Hz 1) 1) = Basis 1 - 4 pcs. / calculate factor 0.5 for 5 - 19 pcs. ! □ = Standard version o.MP. = Without surcharge For dual voltages 230 V/400 V, 220 V/380 V, 400 V/690 V or 380 V/660 V: ● = This order code only determines the price of the version - additional plain text is required. - For motors with a Dahlander circuit, the lower voltage is generally specified. a.A. = On request Voltages not listed are only available on request. - For motors for converter-fed operation, the converter rating plate is stamped with 380 V or 400 V. N = Not available Standard brake supply voltage: 230 V, 1-phase AC Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 87 see PMD N N see PMD a.A. LOHER CHEMSTAR and VARIO 1PS0 motor series Article No. supplements Selection and ordering data Types of construction Mounting Additional Motor series type code identification LOHER CHEMSTAR 12th position code with of the order code Article No. and plain text if required 1PS0. . . - . . . . LOHER VARIO Surcharge / List price EURO Discount level A Discount level C Frame size -.... 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Optional types of construction IM B3 IM B5 2) 0 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 1 95,– 117,– 146,– 199,– 266,– 431,– 508,– 637,– 809,– 1.010,– 1.330,– 1.750,– N N N N IM B34 2 118,– 146,– 189,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N IM B14 IM V1, with canopy - LOHER CHEMSTAR 3 95,– 117,– 146,– a.A. a.A. a.A. N N N N N N N N N N 4 168,– 199,– 243,– 321,– 433,– 699,– 856,– 1.070,– 1.340,– 1.650,– 2.190,– 3.160,– IM V1, with canopy - LOHER VARIO 50Hz 2-pole (11: 0,4,5,6; 14: A) 4 N N N N 5.110,– 6.860,– 11.300,– a.A. IM V1, with canopy - LOHER VARIO 60Hz 2-pole (11: 9; 14: A) 4 6.810,– 9.150,– a.A. a.A. IM V1, with canopy - LOHER VARIO 4-pole (14: B) 4 3.410,– 4.580,– 5.630,– 11.400,– IM V1, with canopy - LOHER VARIO ab 6-pole (14: C,D,E,F,G,H) 4 IM B35 6 IM V1, without canopy IM B6 2) 8 118,– 146,– 189,– 305,– 467,– 546,– 637,– 809,– 3.410,– 4.580,– 5.630,– 7.580,– 1.090,– 1.410,– 1.860,– 2.980,– 3.410,– 4.580,– 5.630,– 7.580,– 95,– 117,– 146,– 199,– 266,– 431,– 508,– 637,– 809,– 1.010,– 1.330,– 2.300,– N N N N 9 M1A o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. a.A. a.A. N N N N IM B7 2) 9 M1B o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. a.A. a.A. N N N N IM B8 2) 9 M1C o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. a.A. a.A. N N N N IM V5 2) 9 M1D o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. a.A. a.A. N N N N IM V6 2) 9 M1E o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. a.A. a.A. N N N N IM V5, with canopy 2) 9 M1F 80,– 84,– 102,– 131,– 171,– 275,– 362,– 454,– 568,– 683,– 909,– 1.410,– N N N N IM V3 9 M1G 94,– 117,– 146,– 199,– 266,– 431,– 508,– 637,– 809,– 1.010,– 1.330,– a.A. N N N N IM V15, with canopy 9 M2K 191,– 228,– 286,– 427,– 634,– 814,– 985,– 1.240,– 1.620,– 2.050,– 2.720,– a.A. N N N N IM V18, with canopy 9 M2M 168,– 199,– 243,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N IM V18, without canopy 9 M2N 95,– 117,– 146,– a.A. a.A. a.A. N N N N N N N N N N Other types of construction and special flange diameters on request ! 2) LOHER CHEMSTAR at frame size 315 / 355 only for direct coupling without vibrations, others on request □ = Standard version o.MP. = Without surcharge ● = This order code only determines the price of the version - additional plain text is required. a.A. = On request N = Not available Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 88 LOHER CHEMSTAR and VARIO 1PS0 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code and plain text 1PS0. . . - . . . . . - . . . . -Z if required Discount level C Frame size 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Special electrical designs / winding protection Design with reduced starting current - factory clarification required and eventually type test needed, a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. ETO-Option (Engineer To Order) without order code Special design according load curve of driven equipment or customer requirements - factory clarification required and eventually type test needed, ETO-Option without order code Adjusting of rating according to customer requirements - factory clarification required and eventually type test needed, ETO-Option without order code Motor protection with 3 PTC thermistors for switching-off - without lightning arresters, sole protection not included A11 114,– 114,– 114,– 145,– 145,– 190,– 190,– 227,– 227,– 240,– 240,– 302,– 1.150,– 1.150,– 1.150,– 2.300,– Motor protection with 2 x 3 PTC thermistors for prewarning / switching-off - without lightning arresters, A12 194,– 194,– 194,– 247,– 247,– 279,– 279,– 333,– 333,– 352,– 352,– 392,– 1.730,– 1.730,– 1.730,– 3.460,– Motor protection with 3 PTC thermistors for switching-off as sole protection with inverter (TMS) A15 N N N N N N N N N N N N 2.500,– 2.500,– 3.000,– 4.000,– Motor protection with 2 x 3 PTC thermistors for prewarning/switching-off as sole protection with inverter (TMS) A16 N N N N N N N N N N N N 3.000,– 3.000,– 3.500,– 4.750,– Temperature measuring of the winding by means of embedded temperature sensor KTY84-130 A23 314,– 314,– 314,– 345,– 345,– 434,– 434,– 471,– 605,– 618,– 618,– 694,– 1.150,– 1.150,– 1.150,– 1.150,– Temperature measuring of the winding by means of embedded temperature sensors 2 x KTY84-130 A25 534,– 534,– 534,– 587,– 587,– 637,– 637,– 691,– 691,– 711,– 711,– 866,– 1.750,– 1.750,– 1.750,– 1.750,– Temperature monitoring of winding with 3 resistance thermometer PT100 - in 2-wire design A60 N N N N 999,– 999,– 999,– 999,– 999,– 999,– 999,– 999,– N N N N Temperature monitoring of winding with 2 x 3 resistance thermometer PT100 - 2-wire design, A61 N N N N a.A. a.A. a.A. a.A. a.A. 1.300,– 1.300,– 1.300,– 1.730,– 1.730,– 1.730,– 1.730,– 3 PT100 resistance thermometers in stator winding, 3-wire circuit from terminals of the auxiliary terminal box A63 N N N N N N N N N N N N 1.150,– 1.150,– 1.150,– 1.150,– 6 PT100 resistance thermometers in stator winding, 3-wire circuit from terminals of the auxiliary terminal box A64 N N N N N N N N N N N N 2.000,– 2.000,– 2.000,– 2.000,– 6 embedded resistance thermometers PT100 without lightning arresters for 4-wire connection from terminals A65 N N N N N N N N N N N N 1.730,– 1.730,– 1.730,– 1.730,– A66 N N N N N N N N N N N N 3.450,– 3.450,– 3.450,– 3.450,– A67 N N N N N N N N N N N N 3.450,– 3.450,– 3.450,– 3.450,– Q40 N N N N N N N N N N N N 4.320,– 4.320,– 4.320,– 4.320,– V80 N N N N N N N N N N N N 3.450,– 3.450,– 3.450,– 3.450,– Q43 N N N N N N N N N N N N 850,– 850,– 850,– 850,– Bearing RTD's-PT100 in 3- or 4-wire type ex sensor instead of ex terminal - optionally possible for V80, A40, A42 Q44 N N N N N N N N N N N N 576,– 576,– 576,– 576,– Inner air-PT100 in 3- or 4-wire type ex sensor instead of ex terminal Q45 N N N N N N N N N N N N a.A. a.A. a.A. a.A. One thermocouple per bearing Q49 N N N N N N N N N N N N 4.320,– 4.320,– 4.320,– 4.320,– Sensor for enclosure vibration monitoring (preferred product) with loose cable - per sensor V14 N N N N N N N N N N N N 1.700,– 1.700,– 1.700,– 1.700,– Sensor for enclosure vibration monitoring (preferred product), without junction box - per sensor V15 N N N N N N N N N N N N 2.880,– 2.880,– 2.880,– 2.880,– 3 Transmitter 4-20 mA for PT100 winding P20 N N N N N N N N N N N N 2.500,– 2.500,– 2.500,– 2.500,– One Transmitter with digital display with Exd or Exi-approval V88 N N N N N N N N N N N N 3.450,– 3.450,– 3.450,– 3.450,– PT100 winding in tolerance class A with calibration certificate sole protection not included round wire winding only - only at form coil winding 6 embedded resistance thermometers PT100 with lightning arresters for 4-wire connection from terminals - only at form coil winding 6 embedded resistance thermometers PT100 in shielded design without lightning arresters for 4-wire connection from terminals - only at form coil winding 6 Exi-slot resistance thermometers PT100 in shielded design with lightning arrestors for 3- and 4-wire connection from terminal - only at form coil winding 2 double RTD's PT100 in shielded design (Ex i) for antifriction or sleeve bearing - 2-wire elements with 4-wire connection ex terminal box Winding RTD's-PT100 in 3- or 4-wire type ex sensor instead ex terminal (not possible for Exi!) - optionally possible for A60, A61, A65, A66 V78 N N N N N N N N N N N N 2.850,– 2.850,– 2.850,– 2.850,– 2) D06 86,– 107,– 129,– 150,– 172,– 193,– 214,– 236,– 257,– 279,– 300,– 320,– 2.200,– 3.080,– 4.000,– 5.320,– 2) D07 124,– 156,– 187,– 218,– 249,– 280,– 311,– 342,– 373,– 404,– 435,– 464,– 2.200,– 3.080,– 4.000,– 5.320,– 2) D08 180,– 225,– 271,– 316,– 361,– 406,– 451,– 496,– 541,– 586,– 631,– 673,– 2.200,– 3.080,– 4.000,– 5.320,– 2) Site altitude max. 1500 m above sea level (observe derating) Site altitude max. 2000 m above sea level (observe derating) Site altitude max. 2500 m above sea level (observe derating) Site altitude max. 3000 m above sea level (observe derating) D09 307,– 383,– 460,– 536,– 613,– 690,– 766,– 843,– 919,– 996,– 1.070,– 1.140,– 2.200,– 3.080,– 4.000,– 5.320,– Cooling air temperature max. 45 °C (observe derating) 2) D11 86,– 107,– 129,– 150,– 172,– 193,– 214,– 236,– 257,– 279,– 300,– 320,– 2.200,– 3.080,– 4.000,– 5.320,– Cooling air temperature max. 50 °C (observe derating) 2) D12 124,– 156,– 187,– 218,– 249,– 280,– 311,– 342,– 373,– 404,– 435,– 464,– 2.200,– 3.080,– 4.000,– 5.320,– Cooling air temperature max. 55 °C (observe derating) 2) D13 180,– 225,– 271,– 316,– 361,– 406,– 451,– 496,– 541,– 586,– 631,– 673,– 2.200,– 3.080,– 4.000,– 5.320,– 2) D14 307,– 383,– 460,– 536,– 613,– 690,– 766,– 843,– 919,– 996,– 1.070,– 1.140,– 2.200,– 3.080,– 4.000,– 5.320,– D15 86,– 107,– 129,– 150,– 172,– 193,– 214,– 236,– 257,– 279,– 300,– 320,– a.A. a.A. a.A. a.A. D16 124,– 156,– 187,– 218,– 249,– 280,– 311,– 342,– 373,– 404,– 435,– 464,– a.A. a.A. a.A. a.A. D17 180,– 225,– 271,– 316,– 361,– 406,– 451,– 496,– 541,– 586,– 631,– 673,– a.A. a.A. a.A. a.A. D18 87,– 107,– 130,– 165,– 206,– 265,– 323,– 478,– 603,– 772,– 1.000,– 1.300,– N N N N Cooling air temperature max. 60 °C (observe derating) 2) Derating acc. to catalogue D 83.1; efficiency class of MLFB unchanged. No surcharge if special voltage is chosen ( MLFB digit 11=9) Cooling water temperature max. 30 °C (consider power reduction) - power reduction acc. to derating table. No surcharge if special voltage is chosen ( MLFB digit 11=9) Cooling water temperature max. 35 °C (consider power reduction) - power reduction acc. to derating table. No surcharge if special voltage is chosen ( MLFB digit 11=9) Cooling water temperature max. 40 °C (consider power reduction) - power reduction acc. to derating table. No surcharge if special voltage is chosen ( MLFB digit 11=9) Cooling temperature less than +40 °C with increased rating -factory clarification required, not applicable at IE2 No surcharge if special voltage is chosen ( MLFB digit 11=9) Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 89 LOHER CHEMSTAR and VARIO 1PS0 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code and plain text 1PS0. . . - . . . . . - . . . . -Z if required Discount level C Frame size 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Special electrical designs / winding protection Utilization acc. to insulation class 155(F) - if DOL duty rating according IEC standard maximal. C12 87,– 107,– 130,– 165,– 206,– 265,– 323,– 478,– 603,– 772,– 1.000,– 1.300,– N N N N C29 43,– 50,– 50,– 66,– 66,– 84,– 84,– 96,– 96,– 112,– 112,– 115,– N N N N No surcharge if special voltage is chosen (MLFB digit 11=9) Rated output of next smaller power in size - IEC rating steps will considered in combination with D06 to D18 No surcharge if special voltage is chosen ( MLFB digit 11=9) Moderately extended speed range at inverter operation V82 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Insulation class F W00 N N N N N N N N N N N N o.MP. o.MP. o.MP. o.MP. Insulation class H W01 535,– 575,– 677,– 677,– 1.030,– 1.100,– 1.210,– 1.350,– 1.660,– 2.040,– 2.400,– 2.550,– Insulation class C W02 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N N N N N 2.070,– 2.210,– 2.420,– 2.690,– 3.310,– 4.090,– 4.780,– N 4.150,– 5.750,– 7.500,– 9.750,– 433,– 473,– 502,– 876,– 1.570,– 1.690,– 2.060,– 2.710,– 3.690,– 4.780,– 5.980,– 7.480,– a.A. a.A. a.A. a.A. 88,– N 88,– N 90,– N 106,– N 484,– N 564,– N 864,– N 1.170,– N 1.420,– N 2.100,– N 2.470,– N 2.900,– N N 1.440,– N 1.440,– N 1.440,– N 1.440,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. Reinforced winding isolation in case of inverter duty (Phase/Phase 2250V Peak / power reduction) - a.A. a.A. a.A. a.A. at LOHER CHEMSTAR MLFB digit 8=2 Sealing of the winding head with silicone rubber W03 Sealing of the cable duct with silicone rubber Abnormal voltage and/or frequency for separate fan drive motor W04 Y81 ● and identification code Other electrical designs Colors and paint finish Inner corrosion protection Loher coating system J08 W10 210,– 234,– 260,– 292,– 331,– 374,– 422,– 476,– 536,– 603,– 679,– 764,– N N N N Coating system N08 - 110µm (C3-medium) - Corrosion category acc. to EN/ISO 12944-5 = C3 V09 89,– 103,– 119,– 139,– 161,– 188,– 217,– 249,– 285,– 325,– 370,– 422,– o.MP. o.MP. o.MP. o.MP. Coating system N14/J08 - 170µm (Chemical industry + On Shore, C5 - Industrial climate) - V10 358,– 406,– 460,– 523,– 600,– 686,– 782,– 890,– 1.010,– 1.150,– 1.300,– 1.470,– 1.440,– 1.440,– 1.440,– 1.440,– W14 148,– 172,– 199,– 231,– 269,– 313,– 361,– 415,– 475,– 542,– 617,– 703,– N N N N Special prime coat system Z05 with inner corrosion protection system J08 W15 419,– 467,– 521,– 584,– 661,– 747,– 843,– 951,– 1.170,– 1.550,– 2.010,– 2.410,– N N N N Coating system Z21/J08 - 210µm (Off Shore, C5M-M) - V11 716,– 812,– 919,– 1.050,– 1.200,– 1.370,– 1.570,– 1.780,– 2.120,– 2.630,– 3.240,– 3.810,– 3.500,– 3.500,– 3.500,– 3.500,– Corrosion category acc. to EN/ISO 12944-5 = C5 (5-15 years) for industrial climate Coating system N14A (Chemical + On Shore, C5 - Industry) Corrosion category acc. to EN/ISO 12944-5 = C5 (5-15 years) for industrial climate Corrosion category acc. to EN/ISO 12944-5 = C5 (5-15 years) - sea-climate Increased layer thickness 275µm for coating system Z21 (C5M-high) - only in combination with V11 - V19 148,– 172,– 199,– 231,– 269,– 313,– 361,– 415,– 475,– 542,– 617,– 703,– 1.440,– 1.440,– 1.440,– 1.440,– V12 1.090,– 1.180,– 1.380,– 1.510,– 1.760,– 1.930,– 2.120,– 2.340,– 2.770,– 3.280,– 3.980,– 4.740,– 8.500,– 8.500,– 8.500,– 9.000,– Corrosion category acc. to EN/ISO 12944-5 = C5 high (>15 years) - sea-climate Special offshore painting S13 related to NORSOK M501 ( C5M-high ) with comments and deviations Corrosion category acc. to EN/ISO 12944-5 = C5 high (>15 years) - sea-climate Special coating system S11/J08 (e. g. submerged motors) V13 478,– 507,– 556,– 658,– 1.080,– 1.190,– 1.460,– 1.680,– 2.040,– 2.960,– 3.760,– 5.400,– 5.500,– 5.500,– 5.500,– 5.500,– Without coating, but primed K24 29,– 29,– 29,– 46,– 46,– 86,– 86,– 86,– 86,– 86,– 86,– 98,– N N N N Without coating K23 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N Outer painting for zink galvanized noise cabinet N08 (110µm) V98 N N N N N N N N N N N N 3.600,– 3.900,– 4.200,– 4.500,– Paint Colours according Munsell or British Standard Y50 ● and N N N N N N N N N N N N 2.300,– 2.300,– 2.300,– 2.850,– 63,– 106,– 106,– 139,– 139,– 194,– 243,– 243,– 243,– 243,– 243,– 243,– 576,– 576,– 576,– 864,– 63,– 106,– 106,– 139,– 139,– 194,– 243,– 243,– 243,– 243,– 243,– 243,– 576,– 576,– 576,– 864,– identification code Standard coating in RAL1004,1018,2000,2004,5009,5012,5015,6003,6011,7000,7011,7031,7038,9002 Y53 ● and standard coating RAL… Special coating in RAL1004,1018,2000,2004,5009,5012,5015,6003,6011,7000,7011,7031,7038,9002 - Y54 ● and special specify special coating system in addition, e.g. V10, V11, W14, etc. coating RAL… RAL colours different to above indicated Y51 ● and special 95,– 159,– 159,– 209,– 209,– 291,– 365,– 365,– 365,– 365,– 365,– 365,– 1.150,– 1.150,– 1.150,– 1.700,– 212,– 212,– 212,– 278,– 278,– 388,– 486,– 486,– 486,– 486,– 486,– 486,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. coating RAL… Special colour not RAL Y71 ● and identification code Other painting combinations / systems or RAL colours to customer specification Design for Zones according to ATEX Design for zone 21 (conductive dust) at mains operation M34 463,– 571,– 647,– 722,– 798,– 959,– 1.040,– 1.110,– 1.190,– 1.260,– 1.340,– 1.410,– a.A. a.A. a.A. a.A. Design for zone 22 (non conductive dust) at mains operation M35 222,– 298,– 373,– 449,– 525,– 601,– 677,– 753,– 828,– 904,– 980,– 1.060,– 2.000,– 2.250,– 2.500,– 3.000,– Design for zone 21 (conductive dust) at inverter operation Design for zone 22 (non conductive dust) at inverter operation M38 498,– 609,– 687,– 764,– 858,– 1.030,– 1.110,– 1.190,– 1.260,– 1.340,– 1.420,– 1.490,– a.A. a.A. a.A. a.A. M39 234,– 311,– 389,– 466,– 560,– 636,– 716,– 794,– 871,– 949,– 1.030,– 1.100,– a.A. a.A. a.A. a.A. Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 90 LOHER CHEMSTAR and VARIO 1PS0 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code and plain text 1PS0. . . - . . . . . - . . . . -Z if required Discount level C Frame size 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Ship design "Operation below deck" Design acc. to GL ( Germanischer Lloyd ), CT 45 °C with manufacturers declaration - non essential W24 168,– 168,– 168,– 168,– 168,– 168,– 236,– 236,– 300,– 436,– 776,– 1.120,– a.A. a.A. a.A. a.A. Design acc. to LRoS ( Lloyds Register of Shipping ), CT 45 °C with manufacturers declaration - non essential W25 168,– 168,– 168,– 168,– 168,– 168,– 236,– 236,– 300,– 436,– 776,– 1.120,– a.A. a.A. a.A. a.A. Design acc. to BV ( Bureau Veritas ), CT 45 °C with manufacturers declaration - non essential W26 211,– 211,– 211,– 211,– 211,– 211,– 296,– 296,– 371,– 544,– 969,– 1.390,– a.A. a.A. a.A. a.A. Design acc. to DNV ( Det Norske Veritas ), CT 45 °C with manufacturers declaration - non essential W27 168,– 168,– 168,– 168,– 168,– 168,– 236,– 236,– 300,– 436,– 776,– 1.120,– a.A. a.A. a.A. a.A. Design acc. to ABS ( American Bureau of Shipping ) CT 50 °C with manufacturers declaration - non essential W28 211,– 211,– 211,– 211,– 211,– 211,– 296,– 296,– 371,– 544,– 969,– 1.390,– a.A. a.A. a.A. a.A. Design acc. to RINa ( Registro Italiano Novale ) CT 50 °C with manufacturers declaration - non essential W29 168,– 168,– 168,– 168,– 168,– 168,– 236,– 236,– 300,– 436,– 776,– 1.120,– a.A. a.A. a.A. a.A. Other certifications, motors for upper deck mounting and approvals to classification W99 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N Q60 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q61 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q62 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q63 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q64 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q65 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q66 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q67 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q68 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Q69 N N N N N N N N N N N N a.A. a.A. a.A. a.A. D23 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N Design acc to GL ( German Lloyd ), AT 45 °C, essential drive with manufacturers declaration 1) Design acc to LRoS (Lloyds Register of Shipping), AT 45 °C, essential drive, manufacturers declaration Design acc to BV (Bureau Veritas), AT 45 °C, essential drive with manufacturers declaration 1) Design acc to DNV (Det Norske Veritas), AT 45 °C, essential drive with manufacturers declaration 1) Design acc to ABS (American Bureau of Shipping), AT 50 °C, essential drive, manufacturers declaration Design acc to RINa (Registro Italiano Novale), AT 50 °C, essential drive, manufacturers declaration Design acc to CCS (China), AT 45 °C, essential drive with manufacturers declaration Design acc to USSR (Russia), essential drive with manufacturers declaration Design acc to PR (Poland), essential drive with manufacturers declaration Design acc to NKK (Japan), essential drive with manufacturers declaration 1) 1) 1) 1) 1) 1) Motor only according to EVPG §1 v. 27.2.08, motor for transportation of passengers and goods 1) Individual certifications D22 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. UL-/CUL-type W19 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N Operation at ambient temperatures down to -50°C and transport down to -50°C - antifriction bearings Motor without CE-mark for export outside the EEA (see EU regulation 640/2009) D02 N N N N N N N N N N N N 5.500,– N 7.700,– N 10.000,– N 13.300,– N Operation at ambient temperatures down to -40°C and transport down to -40°C - antifriction bearings D03 N N N N N N N N N N N N 2.750,– 3.850,– 5.000,– 6.650,– Operation at ambient temperatures down to -30°C and transport down to -40°C - antifriction bearings D04 N N N N N N N N N N N N 1.400,– 1.900,– 2.500,– 3.300,– 1.440,– Electric design according to NEMA MG1-12 D30 N N N N N N N N N N N N 1.440,– 1.440,– 1.440,– China Energy Efficiency Label D34 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N Certificate EAC for Eurasien Customs Union D35 163,– 219,– 219,– 219,– 230,– 230,– 335,– 348,– 348,– 348,– 348,– 348,– N N N N 163,– 219,– 219,– 219,– 230,– 230,– 335,– 348,– 348,– 348,– 348,– 348,– N N N 247,– 260,– 380,– 409,– 482,– 793,– 1.100,– 1.390,– 1.680,– 793,– 1.100,– 1.390,– 1.680,– Design according to GOST-K - incl. Ex-certificate, ETO-Option (Engineer To Order) without order code N N N N Special mechanical designs Terminal box on right hand side ( view onto DE ) K09 Terminal box on left hand side ( view onto DE ) K10 Terminal box on top K11 Speed encoder (Loher preferred brand) Q70 N □ N □ N N □ N 247,– □ N 260,– □ N 380,– □ N 409,– □ N 482,– □ N □ N □ N □ N □ □ □ o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N 2.880,– 2.880,– 2.880,– 2.880,– 1.150,– □ N □ Terminal boxes in IP65 Q71 N N N N N N N N N N N N 1.150,– 1.150,– 1.150,– Cable entry thread metrically different from the standard - thread dimension must be given W30 45,– 45,– 45,– 52,– 52,– 52,– 52,– 52,– 65,– 65,– 65,– 65,– N N N Enlarged connecting for main terminal box - not in combination with K53 (Ex d-terminal box) L00 493,– 644,– 795,– 945,– 1.100,– 1.250,– 1.400,– 1.550,– 1.700,– 1.850,– 2.000,– 2.150,– Undrilled cable gland plate at main terminal box L01 N N N N N N N N N N N N N □ N □ o.MP. N N □ N □ Split terminal box W31 N N N N N N N N N 937,– 1.500,– 1.780,– N N N N 1 x NPT - thread for mains supply ( observe the sizes ) - describe thread, cable gland not in our supply W32 113,– 113,– 113,– 130,– 130,– 130,– 130,– 130,– 163,– 163,– 163,– 163,– a.A. a.A. a.A. a.A. 1 x cable gland standard for not armoured cable - for main terminal box K54 55,– 78,– 78,– 78,– 112,– 112,– 212,– 212,– 249,– 249,– 249,– 249,– N N N N One cable gland standard thread size for auxiliary connection 1 pc. (not armoured cable) W33 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– 55,– N N N N Main terminal with tinned cable lug for copper cable W34 N N N N N N N N N N N N 864,– 864,– 864,– 864,– Clamp terminal for connection without cable lug W35 Special cable gland - one cable gland for mains connection, Y97 ● and not armoured cable, exact cable data needed identification code Auxiliary terminal box non-Ex grey cast iron design - without removable cable gland plate, M50 N N N N N N N N N N N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N 198,– 198,– 198,– 198,– 610,– 610,– 610,– 628,– 628,– 628,– 720,– 720,– 720,– 720,– 1.150,– with metric cable entry thread Auxiliary terminal box-material: stainless steel - not in combination with K53 (Ex d-terminal box) M51 N N N N N N N N N N N N 1.150,– 1.150,– 1.150,– Separate auxiliary box terminal for space heater M52 N N N N N N N N N N N N 576,– 576,– 576,– 576,– P84 N N N N N N N N N N N N 3.500,– 3.500,– 3.500,– 3.500,– Q75 N N N N N N N N N N N N 576,– 576,– 576,– 576,– N N N N N N N N N N N N 864,– 864,– 864,– 864,– Heater in main terminal box Auxiliary terminal box in cast iron design with removable gland plate "undrilled" - not in combination Q76 with K53 (Ex d-terminal box) Auxiliary terminal box in cast iron design with removable gland plate "metric thread drilled and sealed with metal plug" - not in combination with K53 (Ex d-terminal box) 1) Acceptance tests must be selected additionally. For example, for the first motor select F83 or F93, and for each additional motor F01. Inclusive of costs for certification authority and inspector, and shaft test if specified by certification authority. LOHER CHEMSTAR for essential drive is possible on request as an ETO option (Engineer To Order) without an option code. Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 91 LOHER CHEMSTAR and VARIO 1PS0 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code and plain text 1PS0. . . - . . . . . - . . . . -Z if required Discount level C Frame size 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Special mechanical designs Cable led out radially without terminal box with 1m free cable length (4- or 7-core) a.A. N N N N Surcharge each further meter of cable - only in combination with W38 W39 N N N 67,– 91,– 112,– 162,– 162,– 179,– 179,– a.A. a.A. N N N N Connection cable for auxiliaries - only in combination with W38, cable length as main supply W40 W38 N N N N N N 160,– 266,– 160,– 285,– 160,– 304,– 160,– 323,– 160,– 343,– 160,– 362,– 160,– 381,– a.A. a.A. a.A. N N N N Additional separately supplied terminal box made of grey-cast iron with baseplate - main terminal box W41 a.A. a.A. a.A. 228,– 228,– 228,– 348,– 348,– 428,– 428,– a.A. a.A. N N N N Cable entry side DE K83 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. Cable entry side NDE K84 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. Turn of the terminal box about 180 ° K85 o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. Vibration severity grade A - IEC 60034-14 K01 □ □ □ □ □ □ □ □ Vibration severity grade B - IEC 60034-14 - if inverter duty for smallest and highest speed of speed range only K02 516,– 569,– 576,– 620,– 620,– 629,– 673,– 798,– 980,– 1.150,– 1.470,– Shaft and flange with increased precision to DIN42955-R K04 149,– 149,– 149,– 200,– 262,– 367,– 478,– 576,– 700,– 871,– Radial sealing ring on DE-side for flange-mounted types (oil-tight) horizontal mounting K17 58,– 66,– 68,– 75,– 92,– 110,– 143,– 205,– 262,– 338,– Radial sealing ring on DE-side for vertical flange-mounted types (oil-tight) W43 104,– 119,– 122,– 135,– 166,– 197,– 256,– 369,– 478,– Labyrinth sealing for external bearing seal W44 a.A. a.A. a.A. a.A. a.A. a.A. a.A. 698,– 889,– certificate acc. Ex e Bearing for increased lateral forces (roller bearing DE) including regreasing device - including K40 K20 N N N N 519,– 572,– 632,– o.MP. □ 691,– o.MP. □ 714,– o.MP. □ o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. □ □ □ □ 2.580,– 1.500,– 2.250,– 3.000,– 3.750,– 1.020,– 1.170,– 2.000,– 2.250,– 2.500,– 3.000,– 402,– 475,– N N N N 607,– 722,– 840,– N N N 1.140,– 1.320,– 2.180,– 738,– Axial thrust bearing V20 N N N N N N N N N N Regreasing device DE/NDE K40 N N N N 419,– 472,– 532,– 591,– 614,– 638,– Grease-collecting chamber if regreasing is applied W45 Bearing insulation NDE for antifriction bearing - binding for frame size 315 - 500 at inverter operation L27 Shaft earthing device - down to -20°C V36 Fixed bearing DE K94 Fixed bearing NDE L04 □ 369,– a.A. N □ □ a.A. N □ □ a.A. a.A. □ □ a.A. a.A. □ N □ a.A. a.A. □ a.A. □ N N N N N N 360,– 400,– 455,– 548,– 677,– 784,– N N N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. 2.100,– 2.230,– 2.340,– 2.430,– 2.550,– 1.800,– 2.000,– 2.000,– 2.000,– N □ N □ N □ N □ N □ N □ 310,– N □ 340,– N □ 378,– N □ N □ a.A. □ 640,– a.A. □ N a.A. □ N a.A. □ 189,– 189,– 194,– 210,– 431,– 536,– 23,– 23,– 23,– 23,– 46,– 46,– 46,– 46,– 48,– 48,– 205,– 246,– a.A. a.A. a.A. a.A. Special grease Klüber Isoflex SL2 - ETO-Option (Engineer To Order) without order code 30,– 30,– 46,– 92,– 125,– 139,– 139,– 139,– 180,– 180,– 915,– 1.080,– a.A. a.A. a.A. a.A. 278,– 364,– 579,– 1.150,– 1.610,– 1.760,– 1.760,– 1.800,– 1.880,– 2.510,– 3.200,– 3.530,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. Other special grease - ETO-Option (Engineer To Order) without order code 273,– N □ Special grease Klüber Staburags NBU8EP - ETO-Option (Engineer To Order) without order code Special grease Barierta L55/2 - ETO-Option (Engineer To Order) without order code 233,– N □ N N PT100 bearing in tolerance class A with calibration certificate - only in combination with Q44 V76 N N N N N N N N N N N N 2.300,– 2.300,– 2.300,– 2.300,– One transmitter (total 2) 4 - 20 mA for PT100 bearing DE and NDE V83 N N N N N N N N N N N N 6.600,– 6.600,– 6.600,– 6.600,– Sensor for enclosure vibration monitoring Bently Nevada Accelerometers without separate junction box V16 N N N N N N N N N N N N 4.320,– 4.320,– 4.320,– 4.320,– Bearing ventilation at DE for lower bearing temperature for antifriction bearing design grease lubricated V17 N N N N N N N N N N N N 2.850,– 3.200,– 3.450,– 3.700,– Bearing insulation DE- and NDE (DE linked to earth) for antifriction bearing design - V18 N N N N N N N N N N N N 5.150,– 5.150,– 5.760,– 5.760,– Grease extractors for DE and NDE V21 N N N N N N N N N N N N N N N 3.450,– Automatic grease lubricator DE and NDE (suitable for ambient temperature from -15 up to + 50°C) V22 N N N N N N N N N N N N 2.000,– 2.000,– 2.000,– 2.850,– 1.750,– 2.300,– 2.300,– - per sensor horizontal mounting only, (vertical mounting on request) Enlarged grease chamber DE and NDE V25 N N N N N N N N N N N N 1.750,– External earthing ( additionally ) W46 110,– 110,– 114,– 114,– 125,– 143,– 155,– 182,– 204,– 231,– 271,– 300,– N N N VIK design - incl. W14, W69 K30 310,– 363,– 419,– 479,– 546,– 618,– 695,– 778,– 867,– 963,– 1.070,– 1.280,– 3.000,– 4.000,– a.A. N LOHER CHEMSTAR Plus design, including VIK design; IP56 - including K30, K51, W14, W69 and W09 578,– 657,– 713,– 773,– 840,– 983,– 1.060,– 1.140,– 1.230,– 1.330,– 1.540,– 1.750,– N N N N N IP66 shaft sealing, vibration grade similar grade B Second rating plate separately K31 22,– 22,– 22,– 22,– 22,– 70,– 70,– 70,– 70,– 70,– 70,– 70,– 288,– 288,– 288,– 288,– Second rating plate installed in terminal box W47 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 15,– 288,– 288,– 288,– 288,– o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. N N N N 43,– 43,– 43,– 43,– 43,– 71,– 71,– 71,– 89,– 89,– 112,– 115,– 144,– 144,– 144,– 144,– N Additional plate with data at inverter duty - data for quadratic torque speed range 1:10 Y80 ● and and constant torque in speed range 1:3 and 1:10 identification code Additional plate for customer data (each plate) - data / text have to be give with order Y82 ● and identification code Additional data on motor rating plate and on packing sticker - max. 20 digits Y84 43,– 43,– 43,– 43,– 43,– 71,– 71,– 71,– 89,– 89,– 112,– 115,– N N N Plates made of stainless steel W48 55,– 55,– 55,– 55,– 55,– 55,– 70,– 70,– 70,– 70,– 70,– 70,– N N N N Plates in other languages as German or English - mains rating plate or auxiliary plate, W49 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.350,– 1.150,– 1.150,– 1.150,– 1.150,– factory clarification required Additional measures for 2 up to 4 years storage to storage instructions W50 45,– 54,– 65,– 78,– 97,– 106,– 118,– 137,– 143,– 203,– 220,– 300,– 864,– 864,– 864,– 1.150,– Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. A 92 LOHER CHEMSTAR and VARIO 1PS0 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code and plain text 1PS0. . . - . . . . . - . . . . -Z if required Discount level C Frame size 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 881,– 1.010,– 1.120,– 1.260,– 1.260,– 1.370,– 1.250,– 1.500,– 1.750,– 2.000,– 881,– 1.010,– 1.120,– 1.260,– 1.260,– 1.370,– 1.500,– 1.750,– 2.000,– 2.250,– 881,– 1.010,– 1.120,– 1.260,– 1.260,– 1.370,– 2.000,– 2.000,– 2.400,– 2.800,– 802,– 881,– 1.010,– 1.120,– 1.260,– 1.260,– 1.370,– 2.000,– 2.000,– 2.400,– 2.800,– N N N N N N N 2.880,– 2.880,– 2.880,– 2.880,– Special mechanical designs Space heater 230 V - preferably choose M13 K45 412,– 461,– 491,– 512,– 720,– 802,– Space heater 115 V - preferably choose M12 K46 412,– 461,– 491,– 512,– 720,– 802,– Space heater 110 - 120 V (min. 100 V, max. 132 V) M12 412,– 461,– 491,– 512,– 720,– 802,– Space heater 210 - 250 V (min. 200 V, max. 264 V) M13 412,– 461,– 491,– 512,– 720,– Anti-condensation heater with other rated voltages Y83 ● and N N N N N identification code Heater with thermostat V75 Second standard shaft end - VARIO for 50% torque, CHEMSTAR for 100% torque 3) N N N N N N N N N N N N 7.200,– 7.200,– 7.200,– 7.200,– K16 278,– 296,– 324,– 378,– 451,– 544,– 640,– 747,– 860,– 1.020,– 1.240,– 1.400,– 4.000,– 4.500,– 5.250,– 6.000,– Non-standard cylindrical shaft end (diameter identical or smaller as standard) - Y55 ● and 329,– 380,– 450,– 502,– 595,– 680,– 764,– 904,– 1.010,– 1.140,– 1.350,– 2.070,– 1.150,– 1.150,– 1.150,– 1.350,– in case of significant different diameter, especially high pole motors due high torque stress, identification N factory clarification required 3) code Shaft of material 1.7225 3) W51 704,– 704,– 749,– 771,– 1.070,– 1.070,– 1.350,– 1.470,– 1.580,– 1.580,– 1.580,– 2.200,– N N N Shaft of material 1.4021 3) W52 756,– 756,– 787,– 1.010,– 1.500,– 1.780,– 2.010,– a.A. a.A. a.A. a.A. a.A. N N N N W53 1.480,– 1.480,– 1.600,– 1.940,– 2.170,– 2.170,– 2.760,– a.A. a.A. a.A. a.A. a.A. N N N N 2.200,– 3.000,– 3.800,– 4.600,– □ □ □ □ □ 3) = Basis 1 - 4 pcs. / calculate factor 0.5 for basis > 5 - 19 pcs. ! Shaft end of special steel butt-welded ( Material 1.4571 ) Shaft material of alloy steel (1.7225 - 42CrMo4) - only until -40° C L72 N N N N N N N N N N N N Welded standard stator housing for TEFC motors - factory clarification is mandatory, W54 N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. dimensions may differ Welded CU-rotor ( copper-bar rotor ) W55 N N N a.A. 2.910,– 3.110,– 4.220,– 5.270,– 5.560,– 7.310,– 10.300,– 12.200,– □ □ □ Second shaft end for IMB3 up to 100% torque; cylindrical with key Q21 N N N N N N N N N N N N 5.500,– 6.200,– 6.800,– Special rotor for heavy duty starting (e.g. DS-rotor or brass cage rotor) - type test needed Q22 N N N N N N N N N N N N 4.300,– 5.000,– 5.750,– Asynchronous generator design with 1.8 fold runaway speed - 4 pole or higher pole, only W56 109,– 134,– 163,– 206,– 258,– 331,– 404,– 598,– 754,– 965,– 1.250,– 1.620,– N N N Enclosure IP56 K51 268,– 294,– 294,– 294,– 294,– 364,– 364,– 364,– 364,– 364,– 476,– 622,– □ Enclosure IP65 K50 295,– 323,– 323,– 323,– 323,– 401,– 401,– 401,– 401,– 401,– 523,– 684,– 1.350,– 2.890,– 3.350,– Enclosure IP66 L94 369,– 404,– 404,– 404,– 404,– 501,– 501,– 501,– 501,– 501,– 654,– 855,– N N N N Enclosure IP67 K93 N N N N N N N N N N N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. 6.950,– 7.330,– 8.210,– 8.730,– 9.840,– 12.500,– 14.000,– 16.000,– 20.000,– Enclosure IP67 without level switch (resin material for terminal box protection will be shipped as extra package; □ □ 7.700,– 6.650,– N □ 3.350,– W58 a.A. a.A. a.A. a.A. Condensate drain holes sealed with plug W59 N N N N Condensate drain holes sealed with screw W60 N N N N o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. o.MP. 250,– 250,– 250,– 250,– Increased tropicalization, humidity ≥ 80% - LOHER CHEMSTAR incl. V10 and W71, W61 543,– 630,– 702,– 830,– 980,– 1.100,– 1.250,– 1.390,– 1.600,– 1.880,– 2.220,– 2.610,– 2.000,– 2.300,– 2.600,– 2.900,– 8 m submerged, max. 72 h □ □ □ □ □ □ □ □ N N N N LOHER VARIO incl. V10 and P45 Tropical design for outdoor onshore installation L28 Design without fan and fan cover - motor mounted in air stream; without external air stream cooling W62 N N N N N N N N N N N N 2.000,– 2.300,– 2.600,– 2.900,– 132,– 132,– 132,– 132,– 132,– 186,– 186,– 186,– 227,– 227,– 227,– 227,– a.A. a.A. a.A. a.A. factory clarification required, due reduced rating Outer fan with corrosion protection in case of metal fan W63 95,– 113,– 130,– 270,– 315,– Fan of aluminium W64 158,– 188,– 217,– 246,– 275,– 304,– 333,– 363,– N N Fan of steel W65 a.A. a.A. a.A. 1.170,– 148,– 1.170,– 165,– 1.360,– 183,– 1.360,– 200,– 1.690,– 218,– 1.690,– 235,– 1.690,– 253,– 1.710,– 1.710,– □ □ □ □ Outer-fan of brass W66 a.A. a.A. a.A. 1.520,– 1.520,– 1.770,– 1.770,– 2.220,– 2.220,– 2.220,– 2.220,– 2.890,– 1.750,– 2.000,– 2.250,– 2.500,– Outer fan of stainless steel V94 N N N N N N N N N N N N 4.500,– 5.000,– 5.500,– a.A. Special ventilation for on deck motors W67 N N N N 2.730,– 2.730,– 2.780,– 2.910,– 2.910,– 2.960,– 3.040,– 3.140,– a.A. a.A. a.A. a.A. Fan cover of steel sheet (3 mm thickness) W68 a.A. a.A. 1.360,– 1.360,– 1.360,– 1.360,– 1.360,– 1.360,– 1.360,– 1.360,– 1.430,– 1.930,– a.A. a.A. a.A. a.A. Galvanized fan cowl - in K30 and W09 incl. W69 162,– 191,– 219,– 248,– 277,– 306,– 335,– 364,– 392,– 421,– 450,– 480,– a.A. a.A. a.A. a.A. Noise level 3 for rotation CW seen on DE - only for 2-pole motors K37 N N N 767,– 767,– 767,– 767,– 778,– 811,– 878,– 956,– 1.030,– N N N N Noise level 3 for rotation CCW seen on DE - only for 2-pole motors K38 N N N 767,– 767,– 767,– 767,– 778,– 811,– 878,– 956,– 1.030,– N N N N Clockwise rotation viewed to DE - direction of rotation is mandatory for motors frame size 355 in 2-/4-pole design K97 N N N N N N N N N N N o.MP. o.MP. o.MP. o.MP. o.MP. Anti-clockwise rotation viewed to DE - direction of rotation is mandatory for motors frame size 355 in 2-/4-pole K98 N N N N N N N N N N N o.MP. o.MP. o.MP. o.MP. o.MP. Noise reduction: silencer for air inlet (GG3) - only in combination with K97 or K98 L20 N N N N N N N N N N N N Stainless steel grid for air inlet silencer - only in combination with L20 L25 N N N N N N N N N N N N 576,– 576,– 576,– 576,– Noise cabinet with inspection door - zinc galvanized unpainted - noise reduction approx. 15dB(A) based on GG1 V32 N N N N N N N N N N N N 18.500,– 20.500,– 22.400,– 25.000,– Noise jacket, noise reduction approx. 3-5 dB(A) compared to standard GG1 V34 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Operation for both rotations - from 355 in 2-/4-pole increased noise level and reduced power K99 a.A. 3.000,– 3.850,– 4.750,– a.A. Increased switching cycles (max. 3000 starts per year) Q23 N 1.650,– 2.310,– 3.000,– 3.990,– □ 700,– N 850,– N 980,– N 1.100,– N N design Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. □ □ N □ N □ N 93 □ N □ N □ N □ N □ N □ N □ N N 2.200,– 3.080,– 4.000,– 4.000,– LOHER CHEMSTAR and VARIO 1PS0 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code and plain text 1PS0. . . - . . . . . - . . . . -Z if required Discount level C Frame size 355 400 Balancing with full key L68 90 114,– 100 114,– 112 114,– 132 132,– 160 132,– 180 166,– 200 166,– 225 207,– 250 207,– 280 207,– 315 207,– 355 207,– 1.440,– 1.440,– 450 1.440,– 500 1.440,– Support ring for coupling guard L15 N N N N N N N N N N N N 2.000,– 2.000,– 2.000,– 2.500,– Fitting of coupling half (customer-supplied, ready machined and balanced) - supplied 4 weeks L17 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. 2.300,– 2.300,– 2.300,– 3.450,– Machine mounting: bolts, shims and tapered pins for mounting on steel foundation L31 N N N N N N N N N N N N 2.000,– 2.300,– 2.600,– 2.900,– Machine mounting: anchor bolts, sole plates and SS-shims for fixing on concrete base L33 N N N N N N N N N N N N 5.750,– 6.000,– 6.300,– 6.800,– Half key balancing L69 □ □ □ □ Heavy duty rolling contact bearings for extreme radial forces L96 Stainless steel screws and plates Special mechanical designs ahead testing date □ □ □ □ □ □ □ □ □ □ □ □ N N N N N N N N N N N N a.A. a.A. a.A. N W71 185,– 224,– 242,– 307,– 380,– 413,– 464,– 500,– 584,– 738,– 920,– 1.150,– N N N N Stainless steel external bolts P45 N N N N N N N N N N N N 1.150,– 1.400,– 1.650,– 1.900,– Ambient temperature to -40°C; preheating before operation necessary - due needed heater power W73 N N N N N N N N N N N N a.A. a.A. a.A. a.A. Ambient temperature to -40 °C; without preheating before start; without Ex-protection W75 260,– 330,– 400,– 470,– 540,– 610,– 680,– 750,– 820,– 890,– 960,– 1.030,– N N N N Ambient temperature to -60 °C; without preheating before start; without Ex-protection W76 953,– 1.020,– 1.120,– 1.300,– 1.610,– 1.870,– 2.150,– 2.560,– 3.000,– 3.610,– 4.390,– 4.850,– N N N N Mounted pulse encoder 1024 pulses/RPM - 10-30V, HTL - level; non Ex ! - signals A,B,N + inverted signals W80 N N N 1.580,– 1.580,– 1.580,– 1.580,– 2.590,– 2.590,– 2.590,– 2.590,– 2.590,– N N N N Speed encoder non Ex-design with integrated shaft earthing device (Loher preferred brand) V74 N N N N N N N N N N N N a.A. a.A. a.A. a.A. factory clarification required, heating via winding may be needed. Installed heating elements for surcharge. - 1024 pulses/rpm - 10 - 30 V, HTL - level - flameproof design; bearing insulation to be added Hollow shaft encoder (special brand) e.g. Baumer Hübner Q93 N N N Mechanical protection for speed encoder - in combination with V72, V77 M68 N N N N N N N N N N N N 1.150,– 1.150,– 1.150,– 1.150,– Mounted forced ventilation axial - forced ventilation is to define preferably by 10. item of MLFB G17 N N N 1.180,– 1.400,– 1.620,– 1.830,– 2.050,– 2.270,– 2.480,– 2.700,– 3.160,– 2.950,– 3.350,– 4.000,– 4.700,– Mounted forced ventilation radial W81 N N N N N N N a.A. a.A. a.A. a.A. a.A. N N N N Reverse lock for direction of rotation right seen onto DE ( left locked ) - dimensions may differ G48 N N N 2.380,– 2.620,– 2.620,– 2.780,– 3.020,– 3.760,– 4.560,– 4.780,– a.A. 5.760,– 6.500,– 7.200,– 8.650,– Reverse lock for direction of rotation left seen onto DE ( right locked ) - dimensions may differ G49 N N N 2.380,– 2.620,– 2.620,– 2.780,– 3.020,– 3.760,– 4.560,– 4.780,– a.A. 5.760,– 6.500,– 7.200,– 8.650,– Mounted brake, standard design G40 N N N N N N N N 13.900,– 18.000,– 22.100,– a.A. N N N N Mechanical hand release for standard brake K82 N N N 651,– 678,– 678,– 838,– 960,– a.A. a.A. a.A. a.A. N N N N Brake supply voltage AC 400 V/50 Hz 1-phase C01 N N N 82,– 82,– 82,– 82,– 82,– a.A. a.A. a.A. a.A. N N N N Brake supply voltage DC 24 V C00 N N N 61,– 61,– 61,– 61,– 61,– a.A. a.A. a.A. a.A. N N N N Tapered shaft end with shaft nut T36 N N N N N N N N N N N N 9.500,– 9.500,– 9.500,– 9.500,– Micro switch for brake - mandatory for Ex motors or monitoring by other devices W83 N N N 389,– 431,– 431,– 477,– 477,– a.A. a.A. a.A. a.A. N N N N Sun protection shield - fixing parts of mild steel, cover of SS unpainted for vertical motors V87 N N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. 5.750,– 6.500,– 7.250,– 8.000,– Sun protection shield - fixing parts of mild steel, cover of SS unpainted for horizontal motors V99 N N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. 4.000,– 4.000,– 4.500,– 5.000,– Preparation for SPM bearing monitoring, only thread M8 for adapter W84 N N N 287,– 287,– 287,– 287,– 287,– 287,– 287,– 287,– 373,– 864,– 864,– 864,– 864,– Machined surface on motor feet with dowel pin holes Q94 N N N N N N N N N N N N 1.730,– 1.730,– 1.730,– 1.730,– Base frame for height adaptation of max. 2 frame sizes difference Q96 N N N N N N N N N N N N 11.500,– 11.500,– 13.000,– 14.500,– Adaptation of foot- & shaft dimensions to next higher frame size (no terminal box adaptation!) Q97 N N N N N N N N N N N N 5.500,– 6.500,– 7.500,– 8.500,– Adaptation of flange dimensions and flansh fixing holes Provisioned for lateral installation of sun shield Q98 N N N N N N N N N N N N 3.500,– 4.800,– 5.900,– 7.000,– Q99 N N N N N N N N N N N N 2.000,– 2.000,– 2.000,– 2.500,– Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. N 94 N N N N N N N N 4.320,– 4.320,– 5.760,– 5.760,– LOHER CHEMSTAR and VARIO 1PS0 motor series Selection and ordering data Special versions Additional Motor series identification LOHER CHEMSTAR code -Z with Surcharge / List price EURO LOHER VARIO Discount level A order code and plain text 1PS0. . . - . . . . . - . . . . -Z if required Discount level C Frame size 90 100 112 132 160 180 200 225 250 280 315 355 355 400 450 500 Special mechanical designs SPM bearing monitoring: Measuring nipple system 32 - thread M8, DE + NDE G50 N N N 621,– 1.150,– 1.150,– 1.150,– 1.150,– Shock pulse measurement (SPM), fixed sensor and distribution box H05 N N N N N N N N N N N N 4.000,– 4.000,– 4.000,– 4.000,– SPM bearing monitoring: Transducer system 40 - thread M8 W85 N N N 4.350,– 4.350,– 4.350,– 4.350,– 4.350,– 4.350,– 4.350,– 4.350,– 4.350,– N N N N Bearing temperature monitoring with PTC thermistors on DE/NDE W86 N N N N a.A. a.A. 1.110,– 1.110,– 1.110,– 1.110,– 1.110,– 1.110,– N N N N Speed monitoring by inductive proximity switches, Fa. Pepperl + Fuchs A03 N N N N N N N N N N N N 2.300,– 2.300,– 2.300,– 2.300,– 2 single RTD's PT100 for antifriction bearing - 3 or 4 wire from terminal box, rolling-contact bearing - A40 N N N N N N N N a.A. a.A. a.A. a.A. 1.440,– 1.440,– 1.440,– 1.440,– 478,– 478,– 478,– 478,– 478,– 478,– 478,– 478,– 1 x DE and 1 x NDE 2 double resistance thermometers PT100 for 4-wire connection from terminal box, rolling-contact bearing - A42 N N N N N N N N N N N N 2.000,– 2.000,– 2.000,– 2.000,– 2 capillary dial-type thermometers without contacts A70 N N N N N N N N N N N N 2.300,– 2.300,– 2.300,– 2.300,– 2 capillary dial-type thermometers with 2 normally open contacts A71 N N N N N N N N N N N N 3.450,– 3.450,– 3.450,– 3.450,– Bearing temperature monitoring with 1 x PT100 each bearing in 2-wire connection - 2-wire from terminal box A72 N N N N N N 1.390,– 1.390,– 1.390,– 1.390,– 1.390,– 1.390,– N N N N 2 double resistance thermometers PT100 for 3-wire circuit for roller-contact bearing A80 N N N N N N 1.690,– 1.690,– 1.690,– 1.690,– 1.690,– 1.690,– N N N N One dial type thermometer with 2 contacts, capillary principle - Ex i design without supply unit V89 N N N N N N N N N N N N 2.600,– 2.600,– 2.600,– 2.600,– N N N N N N N N N N N 1 x DE and 1 x NDE Engraved tag plate fixed on terminal box V96 N 288,– 288,– 288,– 288,– Shims of SS-material (V4A/AISI316) - 4mm/motor foot - not laminated Q92 N N N N N N N N N N N N 1.730,– 1.730,– 1.730,– 2.000,– Shims of brass material - 4mm/motor foot - not laminated V31 N N N N N N N N N N N N 1.440,– 1.440,– 1.440,– 2.150,– Slotted feet holes Q95 N N N N N N N N N N N N 1.730,– 1.730,– 1.730,– 1.730,– Form coil winding LV-motors V01 N N N N N N N N N N N N a.A. a.A. a.A. a.A. 2 metal test sheets (100 x 150mm) with paint layer for special paint inspection V08 N N N N N N N N N N N N 1.150,– 1.150,– 1.150,– 1.150,– Impact protection - for accessory equipment, per equipment M81 N N N N N N N N N N N N 720,– 720,– 720,– 720,– Brackets for lifting and shifting P42 N N N N N N N N N N N N 2.500,– 2.500,– 2.500,– 2.500,– Provision for housing vibration probe, one flat surface with thread M8 x 1 P63 N N N N N N N N N N N N 720,– 720,– 720,– 720,– Pressure oil connection with cylindrical or stepped shaft end instead of feather key connection Y85 ● and N N N N N N N N N N N N 6.050,– 6.050,– 6.050,– 6.050,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N N N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. B15 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. Extension of liability of defects of 12 to 24 months Q80 39,– 45,– 51,– 62,– 85,– 103,– 132,– 169,– 210,– 301,– 561,– 1.040,– 1.210,– 1.690,– 2.200,– 2.930,– Extension of liability of defects of 18 to 30 months Q81 60,– 70,– 79,– 96,– 131,– 160,– 204,– 261,– 325,– 466,– 868,– 1.610,– 1.870,– 2.620,– 3.400,– 4.520,– Extension of liability of defects of 24 to 36 months Q82 77,– 91,– 103,– 124,– 170,– 207,– 264,– 338,– 421,– 603,– 1.120,– 2.080,– 2.420,– 3.390,– 4.400,– 5.850,– identification code "High-Speed-Motors" for speed range 3600 < N <= 6000 RPM, factory clarification required torque W87 characteristic and nominal frequency adjusted design, performance test of original system may be needed "High-Speed-Motors" for speed range >6000 RPM, factory clarification required torque characteristic and nominal frequency adjusted design, performance test of original system may be needed; ETO-Option (Engineer To Order) without order code Retrofit (description of the special design separately) - adaptation to an existing motor Extension of the liability for defects Extension of liability of defects of 30 to 42 months Q83 291,– 373,– 476,– Extension of liability of defects of 36 to 48 months Extension of liability of defects of 48 to 60 months Q84 141,– 165,– 186,– 226,– 308,– 376,– 481,– 615,– 765,– 1.100,– 2.040,– 3.790,– 4.400,– 6.160,– 8.000,– 10.600,– Q85 197,– 231,– 261,– 316,– 432,– 526,– 673,– 861,– 1.070,– 1.530,– 2.860,– 5.300,– 6.160,– 8.620,– 11.200,– 14.900,– 109,– 128,– 144,– □ = Standard version o.MP. = Without surcharge ● = This order code only determines the price of the version - additional plain text is required. a.A. = On request N = Not available Subject to technical feasibility (combination of options) and technical modifications. The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 95 175,– 239,– 593,– 849,– 1.580,– 2.940,– 3.410,– 4.770,– 6.200,– 8.250,– Documentation for Motors 1PS0, 1PS1, 1PS4 and 1PS5 Additional Surcharge Surcharge identification CHEMSTAR VARIO code -Z with order code U90 Availability for Discount level A Discount level C FS 71 … 355 FS 355 … 500 Documentation languages Frame sizes Docu-package NM1 (=U06+U15+U18+U58) De, En 71 … 355 o.MP. N De, En 71 … 355 246,– N De, En 355 … 500 N o.MP. Installation- and operating instructions, EC-type-examination certificate dimension drawing, wiring diagrams U91 Docu-package NM2 (=U01+U04+U06+U15+U18+U40+U58) Installation- and operating instructions, wiring diagrams, EC-type-examination certificate, LOHER data sheet, manufacturers' declaration, dimension drawing, current-torque characteristic U92 Docu-package TM1 consisting of Data sheet, current-torque characteristic, GA-Drawing, Terminal box drawing, wiring diagrams, installation- and operating instructions, set values U01 LOHER data sheet U02 Customer data sheet De, En, Fr, It, Es, Ru 71 … 500 71 … 500 140,– * 273,– 63,– * 576,– U03 Current-starting-time curve De, En 71 … 500 373,– o.MP. U04 Current-torque characteristic (with indicated load torque characteristic) De, En, Fr, It, Es, Ru 71 … 500 273,– o.MP. U05 Transient air gap torques De, En 71 … 500 415,– 432,– U06 Circuit diagram De, En, Fr 71 … 500 o.MP. o.MP. U07 Equivalent circuit diagram De, En, Fr, It, Es 71 … 500 329,– 144,– U08 Terminal box drawing De, En 71 … 500 273,– o.MP. U09 Wöhler-Curve De, En 355 … 500 N 576,– U10 Indication of the shock proofness De, En 71 … 500 54,– 144,– U11 Calculation of shock proofness De, En 71 … 500 4.000,– 2.000,– o.MP. U12 Foundation load De, En, Fr, It, Es 280 … 500 273,– U13 Calculation of the axial magnetic pull De, En 355 … 500 N 288,– U14 Lateral critical speed analysis De, En 200 … 500 a.A. 3.450,– U15 Dimension drawing De, En 71 … 500 184,– * U16 Speed-starting-time-curve De, En 71 … 500 373,– 288,– U17 Bearing and lubrication data sheet De, En, Fr, It, Es, Ru 71 … 500 54,– o.MP. U18 Installation and operating instructions De, En, Fr, It, Es 71 … 500 0,– o.MP. U19 Shaft drawing with values of torsion stiffness De, En 200 … 500 415,– 576,– U20 Shaft drawing (without values of torsion stiffness) De, En 71 … 500 273,– 144,– U21 Instrument data sheet (all instruments combined) De, En 71 … 500 99,– 288,– U22 Rating plate drawing De, En 71 … 500 99,– 288,– U23 Noise characteristics report (standard) De, En 71 … 500 99,– 288,– U24 Setpoint values (e.g. PT100) De, En 200 … 500 99,– o.MP. 83,– * U25 Water cooler data De, En 355 … 500 U26 Spare parts list with sectional drawing (without prices) De, En 71 … 500 U27 Spare parts list with sectional drawing with prices De, En 355 … 500 N 576,– U28 Drawing motor thermal growth De, En 200 … 500 373,– 576,– U29 Winding data De, En 71 … 500 108,– 864,– U30 Winding diagram De, En 71 … 500 167,– 864,– U31 Shell-Record-Card En 71 … 500 108,– 288,– U32 Test certificate 2.2 (EN 10204) De, En, Fr, It, Es, Ru 71 … 500 o.MP. N U33 SASO-certificate En 71 … 500 535,– N N a.A. o.MP. o.MP. U34 Calculation of the REED-frequency De, En 71 … 500 959,– 294,– U35 Lifting-Transport-Recommendation De, En 71 … 500 174,– 576,– U36 Coating description De, En 71 … 500 54,– * U37 P & ID-Diagram De, En 71 … 500 A U38 Power-Factor-Efficiency-Curve De, En 71 … 500 373,– 432,– U39 Power-Factor-Speed-Curve De, En 71 … 500 373,– o.MP. 24,– * 1.150,– U40 EC-Declaration of conformity De, En 71 … 500 54,– * U41 Certificate of conformity for mounting parts De, En 71 … 500 54,– * 288,– U42 Certificate of conformity for terminal box De, En 71 … 500 54,– * 144,– U43 Declaration of incorporation De, En 71 … 500 a.A. U44 Certificate of conformity of IP-protection De, En 71 … 500 139,– 576,– U45 Lifting-Lug-Calculation De, En 71 … 500 a.A. 432,– U46 Bearing life time calculation De, En 71 … 500 555,– 288,– U47 U50 Air gap calculation De, En 355 … 500 Balance certificate (multi) De, En 71 … 500 24,– * 24,– * N a.A. 167,– 288,– U51 Inspection certificate 3.1 EN10204 (multi) De, En, Fr, Ru 71 … 500 167,– * U52 Type test report (original motor) De, En 71 … 500 413,– 1.440,– o.MP. a.A. 75,– * U53 Type test report (order-specific), only in combination with F82/83 or F92/93 De, En 71 … 500 U54 Load characteristics De, En 71 … 500 o.MP. 273,– U55 Order-specific noise characteristic report according to chosen F-option De, En 71 … 500 a.A. 300,– U56 Vibration test report 3.1 (EN10204) - at no load De, En 71 … 500 a.A. o.MP. U57 Data information - for inverter operation De, En 71 … 500 o.MP. o.MP. U58 EC-type-examination certificate De, En 71 … 500 U59 Acceptance test certificate De, En 71 … 500 o.MP. a.A. o.MP. o.MP. U60 Shaft material certificate 3.1 De, En 71 … 500 415,– 576,– U61 Cooling material certificate 3.1 De, En 355 … 500 U62 Calibration certificates De, En N 576,– 71 … 500 553,– 1.440,– U63 Quality-Plan De, En 71 … 500 139,– 576,– U64 Thermal limit curve De, En 71 … 500 371,– 288,– U65 Temperature rise curve De, En 71 … 500 U66 External certificate according design option various 71 … 500 371,– o.MP. 576,– 576,– 131,– 139,– 1.150,– 288,– U67 Certificate flame path 3.1 De, En 71 … 500 U68 Certificate of Compliance De, En 71 … 500 U69 Manufacturing Record Book De, En 71 … 500 U70 Tangent-delta measuring protocol (complete winding) 3.1 De, En Form coil winding 2.580,– N 2.300,– N U71 Tangent-delta measuring protocol (10% of the coils) 3.1 De, En Form coil winding N N U72 Sample coil test-protocol 3.1 De, En Form coil winding N N U73 Partial discharge measurement report 3.1 De, En Form coil winding N a.A. U74 Material certificate for lamination 2.2 U75 Material certificate for copper 2.2 De, En De, En 71 … 500 71 … 500 355,– 576,– 355,– 576,– * Surcharge only if ordered separate from motor order The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 96 Documentation for Motors 1PS0, 1PS1, 1PS4 and 1PS5 Additional Surcharge Surcharge identification CHEMSTAR VARIO code -Z with order code Availability for Discount level A Discount level C FS 71 … 355 FS 355 … 500 Documentation languages Frame sizes U76 Magnetic particle test report for motor shaft - ≥ FS 315 De, En 315 … 500 a.A. 288,– U77 Magnetic particle test report for lifting eye 3.1 De, En 355 … 500 N 288,– U78 Liquid-penetrant test report for motor shaft 3.1 - ≥ FS 315 De, En 315 … 500 a.A. a.A. U79 Ultrasonic test report for motor shaft 3.1 - ≥ FS 315 De, En 71 … 500 a.A. 288,– U80 Air gap measurement report 3.1 - ≥ FS 315 De, En 315 … 500 a.A. 576,– U81 Layer thickness protocol 3.1 - total layer thickness only De, En 71 … 500 366,– 288,– U82 Protection level certificate De, En 71 … 500 a.A. a.A. U83 Shaft vibration and run out protocol De, En 355 … 500 N 144,– U84 Customer-specific dimension protocol De, En 71 … 500 a.A. 144,– U85 Layer thickness protocol 3.1 of each layer De, En 71 … 500 a.A. 1.150,– U86 Test procedure De, En 71 … 500 373,– 576,– Languages for the main components (e.g. operating and maintenance instructions): D00 Documentation German 71 … 500 o.MP. o.MP. D54 Documentation Czech (operation & safety instructions) 71 … 500 925,– 2.910,– 2.910,– D55 Documentation Polish (operation & safety instructions) 71 … 500 925,– D56 Documentation Russian (manual, datasheet, dimension drawing) 71 … 500 93,– 291,– D57 Documentation Japanese (operation & safety instructions) 71 … 500 925,– 2.910,– D62 Documentation Danish (operation & safety instructions) 71 … 500 925,– 2.910,– D71 Documentation Rumanian (operation & safety instructions) 71 … 500 925,– 2.910,– D72 Documentation Italian (operation & safety instructions) 71 … 500 o.MP. o.MP. D73 Documentation Finnish (operation & safety instructions) 71 … 500 925,– 2.910,– D74 Documentation Dutch (operation & safety instructions) 71 … 500 93,– 291,– D75 Documentation Turkish (operation & safety instructions) 71 … 500 925,– 2.910,– D76 Documentation English 71 … 500 o.MP. o.MP. D77 Documentation French (operation & safety instructions) 71 … 500 o.MP. o.MP. D78 Documentation Spanish (operation & safety instructions) 71 … 500 o.MP. o.MP. D79 Documentation Portuguese (operation & safety instructions) 71 … 500 925,– 2.910,– D80 Documentation Bulgarian (operation & safety instructions) 71 … 500 925,– 2.910,– D81 Documentation Norwegian (operation & safety instructions) 71 … 500 925,– 2.910,– D82 Documentation Hungarian (operation & safety instructions) 71 … 500 925,– 2.910,– D83 Documentation Swedish (operation & safety instructions) 71 … 500 925,– 2.910,– D84 Documentation Chinese simplified (operation & safety instructions) 71 … 500 93,– 291,– D91 Documentation Serbian (operation & safety instructions) 71 … 500 925,– 2.910,– Official EU languages (English/Spanish/French/Italian and German) are available for download. Please consult the factory for availability/delivery time/feasibility. Choose the required documents separately, e.g. U18 or in the package U90, U91 or U92 B00 Without documentation 71 … 500 o.MP. o.MP. B08 Documentation as subject to approval, according selected U-options - 71 … 500 o.MP. o.MP. 71 … 500 360,– 250,– without test reports, delivery time plus 2 weeks B16 Photos for approval before shipment - rating plates + 2 views of motor, delivery after approval by customer B17 Expediting during production - per order position 71 … 500 977,– 1.470,– B21 Documentation on CD 71 … 500 o.MP. o.MP. B22 Documentation as Email 71 … 500 o.MP. o.MP. B23 Documentation on paper 1 set 71 … 500 o.MP. 291,– B24 Predocumentation only 71 … 355 o.MP. N B29 Final documentation only 71 … 355 o.MP. N B43 Document production schedule: Created once 355 … 500 N 288,– B45 Document production schedule: Updated every month 355 … 500 N 576,– B48 Order-specific test schedule 355 … 500 N 864,– Customer entry in drawing: each drawing 149,– 67,– Adding of additional title blocks in all drawings 411,– 185,– Approval documentation 491,– o.MP. Motor sectional drawing A A Special documentation A A Plant- or order-specific issue of operating instructions A A 544,– 245,– 10.700,– 4.830,– (title block has to be made available by the customer as DXF-file) Compilation of end documentation in folder Other languages: Translation costs Please consult the factory for availability/delivery time/feasibility. Type and extent of documentation: E-mail o.MP. o.MP CD-ROM (base price) 140,– o.MP CD-ROM (base price if ordered separately) 329,– 148,– CD-ROM (per CD copy) 72,– 33,– 233,– 105,– Paper (base price if ordered separately) 422,– 190,– Paper (each additional set) 135,– 61,– Paper (base price) N = not available a.A. = on request o.MP. = without surcharge A = to actual cost The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 97 Tests and witnessed tests for 1PS0, 1PS1, 1PS4 and 1PS5 motors Additional identification code For witnessed -Z with order code test with For internal tests customer or inspector Surcharge CHEMSTAR Surcharge CHEMSTAR Surcharge VARIO Surcharge VARIO Internal tests Witnessed test with customer Internal tests Witnessed test with customer Discount level C FS 400 FS 450 Discount level C FS 400 FS 450 or inspector Documentation Discount level A FS 71-132 FS 160-315 or inspector Discount level A FS 71-132 FS 160-315 FS 355 Test description Frame size F01 U51 Routine test according IEC (sine wave voltage) 71 … 500 F03 1) Visual inspection 71 … 500 F14 F15 2) Recording of no-load characteristic 71 … 500 a.A. a.A. a.A. a.A. a.A. a.A. 860,– 860,– 860,– F16 F17 2) Recording of short-circuit characteristic 71 … 500 588,– 588,– 588,– 657,– 657,– 657,– 860,– 860,– 860,– F28 F29 U55 No load noise measurement, without noise analysis 71 … 500 588,– 588,– 588,– 1.550,– 1.550,– 1.550,– 880,– 880,– 880,– F46 F47 U73 Measurement of partial discharge Pre-formed coil F52 F53 1) 2) Measurement of starting torque and -current 71 … 500 F54 F55 1) 2) Measurement of polarization index F56 F57 1) 2) Measurement of shaft vibrations Vibration modal analysis (2-pole and V1 fixed mounted) Noise level analysis - octave-band analysis in F00 (Standard) - U56 1) 2) □ FS 355 □ N □ N N FS 355 FS 500 FS 355 FS 500 1.590,– 2.980,– 6.280,– □ □ □ □ 2.020,– 2.020,– 2.880,– 3.460,– 959,– 959,– 959,– N N N N 1.440,– 1.440,– 1.440,– 1.440,– 860,– 1.150,– 1.150,– 1.150,– 1.150,– 860,– 1.150,– 1.150,– 1.150,– 1.150,– 880,– 1.450,– 1.450,– 1.450,– 1.450,– N N N N N N a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. 588,– 588,– 588,– a.A. 657,– 657,– 860,– 860,– 860,– 860,– 1.150,– 1.150,– 1.150,– 1.150,– Pre-formed coil N N N N N N 860,– 860,– 860,– 860,– 1.150,– 1.150,– 1.150,– 1.150,– 355 … 500 N N N N N N 864,– 864,– 864,– 864,– 1.440,– 1.440,– 1.440,– 1.440,– 71 … 500 a.A. a.A. a.A. a.A. a.A. a.A. 2.020,– 2.020,– 2.020,– 2.020,– 2.590,– 2.590,– 2.590,– 2.590,– 71 … 500 1.110,– 2.080,– 4.400,– 1.590,– 2.980,– 6.280,– 2.020,– 2.020,– 2.020,– 2.020,– 2.880,– 2.880,– 2.880,– 2.880,– 2.780,– 3.640,– 4.150,– N N N 4.320,– 4.320,– 4.320,– 4.320,– N N N N N N N N N N □ 1.440,– 1.440,– 1.440,– 1.440,– a.A. a.A. a.A. a.A. a.A. a.A. 2.020,– 2.020,– 2.020,– 2.020,– 2.880,– 2.880,– 2.880,– 2.880,– F58 F59 F62 F63 U55 F70 - U79 Ultrasonic test on motor shaft with certificate 71 … 500 Standard F71 U50 Rotor balancing 355 … 500 F74 F75 U55 Noise test at load, without noise analysis - 71 … 500 combination with F28/29 or F74/75 □ □ □ in combination with type test F82/83 or F92/93 F76 - U76 Magnetic particle test on motor shaft 315 … 500 N 3.640,– 4.150,– N N N 4.320,– 4.320,– 4.320,– 4.320,– N N N N - F77 U81 Painting inspection (order sample paint sheets 71 … 500 N N N a.A. a.A. a.A. N N N N 1.150,– 1.150,– 1.150,– 1.150,– F78 - U77 Magnetic particle test on motor lifting lugs 355 … 500 N N N N N N 4.320,– 4.320,– 4.320,– 4.320,– N N N N - F79 - Packaging inspections by Third Party Inspector or 71 … 500 N N N 766,– 766,– 766,– N N N N 1.730,– 1.730,– 1.730,– 1.730,– F82 F83 U53 71 … 500 7.060,– 9.370,– 10.800,– 7.770,– 12.500,– 16.700,– 5.760,– 5.760,– 7.200,– 8.640,– 8.640,– 8.640,– 10.100,– 11.500,– 71 … 500 7.060,– 9.370,– 10.800,– 7.770,– 12.500,– 16.700,– 7.200,– 7.200,– 8.640,– 10.100,– 10.100,– 10.100,– 11.500,– 13.000,– separately with V08) customer Type test with heat run for horizontal motors acc. to IEC (sine wave voltage) F92 F93 U53 Type test with heat run for vertical motors acc. to IEC (sine wave voltage) - F95 U53 Type test, motor together with SINAMICS G180 converter 71 … 500 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. 28.800,– 36.000,– 43.200,– 50.400,– - F97 U53 Type test, motor together with SINAMICS G/S or 71 … 500 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. 43.200,– 50.400,– 64.800,– 72.000,– 71 … 500 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. 57.600,– 64.800,– 79.200,– 93.600,– PERFECT HARMONY (max. 3 days service technician for converter adjustment not included) - F99 U53 Type test, motor together with non-Siemens converter (max. 3 days service technician for converter adjustment not included) - - Special test on request 71 … 500 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. - - Special tests in combination with manufacturing of test 71 … 500 a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. equipment; special shafts and special mounting types on request - - Ship acceptance to MS 109 type test 4) 71 … 500 N N N 7.020,– 11.300,– 15.900,– N N N N a.A. a.A. a.A. a.A. - - Ship acceptance to MS 109 routine test 4) 71 … 500 N N N 1.430,– 2.660,– 5.990,– N N N N a.A. a.A. a.A. a.A. - - Impact notch test and tensile test of the shaft Special test: Measurement of tightening torque 71 … 500 71 … 500 2.240,– 706,– 2.580,– 1.040,– 3.150,– 2.240,– N 841,– N 1.250,– N 2.620,– a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. N a.A. N a.A. N a.A. N a.A. 1) Only in combination with a type test F82/83 or F92/93: document U53. 2) Only in combination with a routine test, at acceptance F01: document U51. 3) Protocols according separate order. 4) The costs of the acceptance verifier (expenses, etc.) himself as well as the fees of the classification companies will be charged separately and upon expenses ! □ = Standard version a.A. = on request N = not available The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 98 Test fees for 1PS0, 1PS1, 1PS4 and 1PS5 motors Surcharge CHEMSTAR Discount level A FS 160-315 Frame sizes PTB New approval order-specific with type test 71 … 500 6.840,– 7.500,– 8.570,– a.A. a.A. a.A. a.A. PTB Supplement order-specific with routine test and existing type test 71 … 500 3.620,– 4.000,– 4.840,– a.A. a.A. a.A. a.A. PTB Supplement order-specific with type test 71 … 500 3.620,– 4.000,– 4.840,– a.A. a.A. a.A. a.A. PTB Supplement/approval standard motor => 6-pole and pole-changing or noise level 3 71 … 500 1.710,– 1.710,– 1.710,– a.A. a.A. a.A. a.A. SEV Fees 71 … 500 a.A. a.A. a.A. a.A. a.A. a.A. a.A. FTZU Fees 71 … 500 a.A. a.A. a.A. a.A. a.A. a.A. a.A. GOST Fees 71 … 500 a.A. a.A. a.A. a.A. a.A. a.A. a.A. BKI Fees 71 … 500 a.A. a.A. a.A. a.A. a.A. a.A. a.A. BVS Fees 71 … 500 a.A. to actual cost a.A. to actual cost a.A. to actual cost a.A. to actual cost a.A. to actual cost a.A. to actual cost a.A. to actual cost Spark ignition test, routine test a.A. a.A. a.A. a.A. a.A. a.A. a.A. Spark ignition test, type test Various a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. a.A. Please observe: Possibly required type tests / routine tests have to be invoiced additionally acc. to the surcharge list for tests ! The indicated amounts are only the test fees (without test costs) ! a.A. = on request The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 99 FS 355 FS 355 Discount level C FS 400 FS 450 Test fees Fees due to shipping classification FS 71-132 Surcharge VARIO FS 500 Freight charges Applicable to Type series A… / D... Basic-MLFB : 1PS0 / 1PS1 / 1PS5 / 1MD5 Freight charges industrial motors 1 2 3 Motor type Weight approx. Motor dimensions Terminal box on top l [mm] b [mm] h [mm] Volume (Box +100mm) Airfreight packing m³ seaworthy packing 1/2/3 FOB German Seaport (Hamburg) C&F Yokohama / Japan C&F Australia Sydney C&F Singapore C&F United Arab. Emirates C&F East coast USA Chicago A.. / E.. [kg] Euro Euro Euro Euro Euro Euro Euro Euro 090LB-04 22 324,5 180 252 0,042 124,– 1.010,– carton box 566,– 382,– 524,– 222,– 415,– 453,– 100LD-04 38 382,5 205 285 0,057 124,– 1.010,– carton box 588,– 382,– 524,– 222,– 415,– 453,– 112MB-04 41 389 230 303 0,065 124,– 1.010,– carton box 604,– 382,– 524,– 222,– 415,– 453,– 132SB-04 59 458 260 365 0,093 124,– 1.010,– carton box 637,– 382,– 524,– 222,– 415,– 453,– 132MB-04 69 496 260 365 0,1 124,– 1.010,– carton box 657,– 382,– 524,– 222,– 415,– 453,– 160MB-04 108 580 310 417 0,144 168,– 1.190,– carton box 799,– 382,– 524,– 222,– 415,– 453,– 160LB-04 130 624 310 417 0,153 168,– 1.190,– carton box 835,– 382,– 524,– 222,– 415,– 453,– 180MB-04 162 646 345 478 0,192 168,– 1.190,– carton box 890,– 382,– 524,– 222,– 415,– 453,– 453,– 180LB-04 176 684 345 478 0,202 168,– 1.190,– carton box 906,– 382,– 524,– 222,– 415,– 200LG-04 254 766 400 525 0,271 284,– 1.190,– carton box 1.090,– 382,– 524,– 222,– 415,– 453,– 225SE-04 305 818 450 575 0,341 284,– 1.580,– carton box 1.170,– 382,– 524,– 222,– 415,– 453,– 225ME-04 335 843 450 575 0,35 284,– 1.580,– carton box 1.210,– 382,– 524,– 222,– 415,– 453,– 250ME-04 425 937 505 650 0,471 284,– 1.580,– carton box 1.390,– 382,– 524,– 222,– 415,– 453,– 453,– 280SG-04 575 1004 570 729 0,61 426,– 1.580,– carton box 1.600,– 382,– 524,– 222,– 415,– 280MG-04 650 1055 570 729 0,64 426,– 1.580,– carton box 1.670,– 382,– 524,– 222,– 415,– 453,– 315SB-04 795 1200 630 810 0,86 426,– 2.550,– wood. crate 1.820,– 382,– 524,– 222,– 415,– 453,– 453,– 315MB-04 890 1251 630 810 0,9 426,– 2.710,– wood. crate 1.960,– 382,– 524,– 222,– 415,– 315MD-04 960 1251 630 810 0,9 426,– 2.710,– wood. crate 2.030,– 382,– 524,– 222,– 415,– 453,– 315LB-04 1165 1328 875 713 1,13 426,– 3.620,– wood. crate 2.200,– 453,– 555,– 244,– 486,– 486,– 355MB-04 1650 1440 990 819 1,54 484,– 4.570,– wood. crate 2.640,– 486,– 593,– 264,– 544,– 524,– 355LB-04 1885 1510 990 819 1,61 535,– 5.970,– wood. crate 2.800,– 524,– 624,– 286,– 586,– 586,– Packings into the former Sovjet Union and China off the seaports ==> no carton boxes possible !! Packings for Australia, New Zealand, USA, Canada, Mexico and China in the 200 km coast area + 20% for special treatment of the wood used. Prices are based on packing of one motor. For other batch sizes or projects the packing sizes and thus the prices can be reduced ==> on request The prices are recommended without obligation. Price List LOHER Motors 2015 Version a. 100