When operated at rated voltage and frequency, the temperature rise of the motor windings, above the
ambient temperature should not exceed the values in the following table. Note that separate values
are given for motors with a 1.0 service factor and 1.15 service factor. The values given in the table for
1.0 service factor are for motors operated at rated load or nameplate horsepower. The values given
for 1.15 service factor are for motors operated at service factor load.
Maximum Winding Temperature Rise °C
1.0 Service Factor
Insulation Class
A
B
F
H
60 80 105 125
1.15 Service Factor
A
B
F
70
90 115
Temperature rise values are by resistance method of determination when operated on a 60Hz
utility sine wave.