Current (A]
DERATING CURVE (Current carrying capacity acc. IEC 60512-5-2 Test 5b)
MicroSpeed Power Module, 5pins, max. temperature 150°C
standard & blindmate, M1 F4 straight & right angled, SMT & SMT/TH
25
20
15
10
5
Base curve [A]
Derating curve [A]
Temperature [°C]
0
Base curve [A]
Derating curve [A]
0
10
20
30
40
50
60
70
80
90
100
110
22,6 21,7 20,8 19,8 18,8 17,6 16,4 15,14 13,8 12,3
18,08 17,36 16,64 15,84 15,04 14,08 13,12 12,11 11,04 9,84
All rights reserved. Only for information. Subject to modification without prior notice.
120
10,5
8,40
130
8,6
6,88
140
6
4,80
150