My-Com precision switches MY-COM L My-Com precision switches sample drawing 4 M8 x 0,5 30 40 SW10 LED M8 x 1 general data sample picture repeat accuracy < 0,001 mm activating force 75 cN mech. pre-run / overrun - / 0,6 mm approx. measurement type contact with medium direction of approach frontal output indicator LED red electrical data voltage supply range +Vs 5 ... 36 VDC load current max. at 24 VDC 50 mA load resistance min. 480 Ohm mechanical data activating pin ruby housing material brass nickel plated dimension 8 mm type cylindrical threaded ambient conditions operating temperature -20 ... +75 °C protection class IP 67 order reference output circuit connection types housing length MY-COM L75N/S35L NPN make function (NO) connector M8 40 mm MY-COM L75N80/L NPN make function (NO) cable, 80 cm 30 mm MY-COM L75P/S35L PNP make function (NO) connector M8 40 mm MY-COM L75P80/L PNP make function (NO) cable, 80 cm 30 mm 1 www.baumer.com 19/1/2015