View detail for Atmel AVR146: Lithium-Ion Battery Charging via USB with ATmega16/32U4

AVR146: Lithium-Ion Battery Charging via USB
with ATmega16/32U4
Features
•
•
•
•
•
•
Fully Functional Design for Charging Lithium-Ion Batteries
High Accuracy Measurement with 10-bit A/D Converter
Modular “C” Source Code
Easily Adjustable Battery and Charge Parameters
Analog Inputs for Reading Battery ID and Temperature
USB CDC class for user interface
8-bit
Microcontrollers
Application Note
1 Introduction
This application note is based on the ATmega16/32U4 and focuses on how to use
the EVK527 evaluation kit to charge Lithium-Ion (Li-Ion) batteries using USB
connection as power supply.
The USB CDC class offers an easy interface to display charge parameters.
This application note is derived from:
AVR458: Charging Lithium-Ion Batteries with ATAVRBC100
The firmware is written entirely in C language (using IAR® Systems Embedded
Workbench) and is easy to port to other AVR® microcontrollers.
Rev. 7801A-AVR-06/08
2 Description
This document describes an application running on the EVK527 evaluation kit. The
EVK527 is dedicated to ATmega16/32U4.
The USB offers a 5V power supply on the VBUS pin. The available current range is
from 100mA to 500mA. This is enough to charge a Li-Ion battery cell.
A Li-Ion cell needs a precise control of voltage and current during charge.
ATmega16/32U4 offers a USB full speed interface, PWM channels and 10 bit-ADC
channels. All these features are used to perform a Li-Ion battery charger via USB.
Figure 2-1. Hardware Description.
EVK527
PC
USB Link
Battery
For a user friendly interface, all charging parameters (charging status, battery voltage,
charge current, battery temperature…) are displayed on the PC without the use of
measurement tools.
After the USB enumeration, a virtual communication port is declared (see Fig1.2). A
HyperTerminal window connected to this communication port displays charging
parameters. The communication port is virtual therefore HyperTerminal port settings
(speed, parity…) are not taken into account. The user can select the default
configuration.
2
AVR146
7801A-AVR-06/08
AVR146
Figure 2-2. Device Manager Window.
2.1 Displaying Charging Parameters on the PC
The application performs a continuous update of parameters displayed on the PC. If
no battery is detected and identified, the charger is not started. The State of Charge is
only available in Constant Voltage Charge stage (see §3.2.3).
When HyperTerminal is running, the user must push the HWB button to start sending
information to the PC.
Figure 2-3. User interface after a battery detected.
VARTA EASY PACK 550mAh
Batt voltage = 3.80V
Batt current = 100mA
Batt temperature = 26°
Charging stage:
CONSTANT VOLTAGE CHARGE
State of Charge:
60% (full charge =100%)
3
7801A-AVR-06/08
3 Theory of Operation
Battery charging is made possible by a reversible chemical reaction that restores
energy in a chemical system. Depending on the chemicals used, the battery will have
certain characteristics. A detailed knowledge of these characteristics is required in
order to avoid inflicting damage to the battery.
3.1 Li-Ion Battery Technology
Lithium-Ion batteries have the highest energy/weight and energy/space ratios of
modern rechargeable batteries (See Reference 1 on page 34). It is currently the
fastest growing battery system on the market, with end applications such as notebook
computers, cell phones, portable media players, Personal Digital Assistants (PDA),
power tools and medical devices.
Compared to traditional rechargeable batteries, Li-Ion batteries have low internal
resistance, high cycle life, fast charge time, low self-discharge, low toxicity and no
maintenance requirements. For example, lithium-ion cells with cobalt cathodes hold
twice the energy of a nickel-based battery and four-times that of lead acid. Lithium-ion
is a low maintenance system, an advantage that most other chemistries cannot claim.
There is no memory effect with lithium-ion and the battery does not require scheduled
cycling to prolong its life. Lithium-ion has a low self-discharge and is environmentally
friendly. Disposal causes minimal harm.
Drawbacks of Li-Ion batteries include low tolerance of overcharge and the need for
embedded protection circuitry. An electrical short can result in a large current flow, a
temperature rise and thermal runaway in which flaming gases are vented.
3.1.1 Safety
Lithium-ion batteries are safe, provided certain precautions are met when charging
and discharging. In addition, battery manufacturers ensure a high level of reliability by
adding three layers of protection, as follows:
1. The amount of active material is limited to achieve a workable equilibrium of
energy density and safety.
2. Various safety mechanisms are included within each cell.
3. An electronic protection circuit is added inside the battery pack.
Cell protection devices work as follows:
• A PTC/NTC (positive/negative temperature coefficient) device acts as a protection
to inhibit high current surges.
• The CID (circuit interrupt device) opens the electrical path if an excessively high
charge voltage raises the internal cell pressure.
• The safety vent allows a controlled release of gas in the event of a rapid increase
in cell pressure.
4
AVR146
7801A-AVR-06/08
AVR146
The electronic protection circuit works as follows:
• A solid-state switch is opened if the charge voltage of any cell reaches a given
threshold.
• A fuse cuts the current flow if the skin temperature of the cell approaches 90°C
(194°F).
• The current path is cut when cell voltage drops below a given threshold. This is in
order to prevent the battery from over-discharging.
Today, lithium-ion is one of the most successful and safe battery chemistries
available with billions of cells being produced every year.
3.2 Charging Li-Ion Batteries
There is only one way to charge lithium-based batteries. Manufacturers of Lithium-Ion
cells have very strict guidelines in charge procedures and the packs should be
charged as per the manufacturers "typical" charge technique.
Li-Ion batteries are charged using constant voltage (after having reached the nominal
charge voltage), with current limiter to avoid overheating in the initial stage of the
charging process. Charging is terminated when the charge current drops below a
threshold set by the manufacturer. Several parameters are monitored during the
charge: charge time, battery temperature… The battery takes damage from
overcharging and may explode if overcharged.
3.2.1 Safety
Static electricity or a faulty charger may destroy the battery's protection circuit and
turn solid-state switches to a permanent ON position. This may happen without the
user knowing. A battery with a faulty protection circuit may function normally but does
not provide protection against abuse.
Consumer grade lithium-ion batteries cannot be charged below 0°C (32°F). If charged
at cold temperatures, battery packs may appear to be charging normally but chemical
reactions inside the cells may cause permanent damage and can compromise the
safety of the pack.
The battery will become more vulnerable to failure if subjected to impact, crush or
high rate charging.
The battery must remain cool. A battery pack that gets hot during charge should not
be used.
3.2.2 Priming & Charge Intervals
Unlike many other types of rechargeable batteries, Lithium-Ion batteries do not need
th
th
priming. The first charge of a Li-Ion battery is no different than the 10 or the 100
charge.
Lithium-ion batteries may be – and should be – charged often. The battery lasts
longer with partial rather than full discharges. Full discharges should be avoided
because of wear.
The battery loses capacity due to aging, whether used or not.
5
7801A-AVR-06/08
3.2.3 Charge Stages
Lithium-Ion battery charge follows three stages:
1. Prequalification current: Charging of a Li-Ion battery starts with a test of battery
voltage. If the voltage is under a defined threshold (PREQUAL_VOLTAGE), the
charge starts with a fixed low current.
2. Constant current. The charge continues with applying constant current to the
battery. The size of the charge current is battery-dependent and given by the
manufacturer. This stage is complete when battery voltage has reached the
threshold given by the manufacturer.
3. Constant voltage. After battery threshold voltage has been reached the charger will
switch from supplying constant current to supplying constant voltage. This stage is
complete when charge current has dropped below the threshold given by the
manufacturer.
The below figure illustrates voltage and current of a lithium-ion battery during
charging.
Figure 3-1. Charge stages and limits of a VARTA™ EasyPack 550mAh
Voltage/Current
OVERCHARGE VOLTAGE LIMIT
Vbatt
4.2V
3V
OVERDISCHARGE VOLTAGE LIMIT
260mA
Ibatt
100mA
10mA
ICUTOFF
t
CONSTANT CURRENT CHARGE
CONSTANT VOLTAGE CHARGE
In the figure above, “Overcharge” is the level at which cell protection circuitry cuts in
and opens a solid-state switch and discontinues the charge current path. After this,
battery voltage typically needs to drop several hundred millivolts before the current
path is restored. “Overdischarge” is the level at which the current path is cut in order
to prevent the battery from over-discharging.
6
AVR146
7801A-AVR-06/08
AVR146
3.3 VARTA™ battery
3.3.1 Typical Charge Characteristics
Battery specifications should always be verified from manufacturer’s data sheets.
Below is a summary of typical lithium-ion battery charge characteristics. Actual
parameters may vary.
Table 3-1. Typical Charge Characteristics
Parameter
Typical Value
Charge time
3 hours
1 C1
Charge current
Charge efficiency
99.9 %
Charge current threshold
0.03 C1
Charge voltage
4.20 V
Charge voltage tolerance (per cell)
± 0.05 V
Temperature range
0 … +45 °C
Humidity range
65 ± 20 RH
1. C corresponds to the typical Rated capacity value (see Table 3.2)
3.3.2 Typical Battery Characteristics
The table below summarises manufacturer’s data for the batteries types used in this
application. Other types of batteries may be used, but may require adjustments to
software and/or hardware.
Table 3-2. Manufacturer’s data for VARTA™ EasyPack range of lithium-ion batteries
Parameter
Rated capacity (typical)
EZPack
S-3.7V
EZPack
M-3.7V
EZPack
L-3.7V
EZPack
XL-3.7V
Unit
550
750
1000
2000
mAh
Nominal voltage
3.70
V
2.75 … 4.20
V
Charge voltage
4.20
V
Charge voltage tolerance
± 50
mV
Operating voltage range
Charge current
520
720
955
955
mA
Charge cut-off time
3
3
3
4
hours
Charge cut-off current
10
14
19
38
mA
3.9
6.8
10
24
kΩ
1
RID (resistor ID)
NTC
10
kΩ
B-value
3435
K
Overcharge detection
4.35
V
Overdischarge detection
2.20
V
2
1. RID: Battery internal resistor identifies the capacity of battery connected.
2. B value is used in temperature formula.
7
7801A-AVR-06/08
3.3.3 Electrical pinout
This application uses a particular type of lithium-ion batteries and all configurations
presented here are based on manufacturer’s data. Other lithium-ion batteries may
naturally be used but it is up to the user to look up battery data from manufacturer’s
data sheets and make sure necessary adjustments are made to firmware and
hardware.
The figure below illustrates connection pads of the lithium-ion batteries used in this
application.
Figure 3-2. Connection pads of a VARTA™ EasyPack cell.
The battery is connected to the battery charger as follows.
Table 3-3. Connecting battery to charger
Battery Connector
Charger Connector
Note
- (minus)
BATTERY-
NTC
NTC/RID
Battery temperature measurement
ID
SCL
RID, Battery identification resistor
+ (plus)
BATTERY+
3.4 VBUS Supply Voltage
USB powered applications fall into one of the three following categories:
• Low-Power Bus The low power bus powered functions derive all their power from
VBUS and must not draw more than 1 unit load (100mA) according to the USB
standard. It must also be able to work between the VBUS voltage of 4.40V and
5.25V.
• High-Power Bus The high power bus powered functions derive all their power
from VBUS and cannot draw more than 100mA until it has been configured. Once
configured, it can draw up to 5 unit loads (500mA) by requesting it in its descriptor.
At full load, it must be able to work between the VBUS voltage of 4.75V and
5.25V.
8
AVR146
7801A-AVR-06/08
AVR146
• Self-Power Self powered functions can draw up to 100mA from VBUS and the
rest from another source.
The current to power the EVK527 and to charge the battery comes from VBUS. The
EVK527 must limit the charge current if needed.
An easy solution is to modify the I charge parameter in the lookup table.
For example, a 550mAh battery allows a 260mA charging current. A modification of
this parameter to 90mA (for example) allows connecting the charger on a Low Power
Bus, knowing that the EVK527 consumption with an 8MHz oscillator is about 10mA.
In this case, the prequalification current must also be limited to 90mA.
3.5 EVK527 Revision
The EVK527 Rev1.0.0 must be updated as follows:
• The shunt resistor must be connected between PF0 and PF1 to use the differential
input mode. PF0 must replace PD4 and SP6 must be “without solder” (different of
default configuration).
• Gate pin and Source pins of Q1A must be disconnected.
• R6 and R7 new values are 13kOhms
• R3 new value is 1Ohm
Schematics given in §6 don’t show these modifications.
3.6 Buck converter
A buck converter is integrated on EVK527 to control the battery voltage and the
battery current. The switch is controlled by the High speed PWM output.
Figure 3-2. Buck converter schematic.
BATTERY
9
7801A-AVR-06/08
3.6.1 PWM frequency
The PWM speed for the PWM is programmed to the maximum (64MHz). The source
clock is the PLL output (96MHz) used both by USB and PWM.
A postscaler offers a 1.5 division for the PLL signal: 96MHz/1.5 = 64MHz (see
PLLTM1 and PLLTM0 in PLLFREQ register).
The result on the PWM output signal is a 250kHz frequency:
64MHz / 256 = 250kHz
Where 256 is the size in bit of the in OCR4A compare register used in Timer 4.
Figure 3-2. PWM output signal.
PWM
output
ton
toff
t
The software controls the battery voltage/current in modifying the duty cycle of PWM
output. If ton increases, the battery voltage/current receives a more important energy
load.
10
AVR146
7801A-AVR-06/08
AVR146
4 Battery Charger Software
4.1 Scheduler
A scheduler is implemented to call indefinitely defined tasks. Before starting this
infinite loop, init functions are called.
There are three tasks. Each task is called after the end of the previous one (no preemption).
Figure 4-1. Scheduler
Scheduler Init:
Usb_task_init()
CDC_task_init()
Batt_task_init()
Scheduler task:
Usb_task()
CDC_task()
Batt_task()
4.2 List of files
The firmware is written in C language using IAR Systems Embedded Workbench®,
version 5.10. Since the firmware has been written entirely in C, it should not be a
difficult task to port it to other AVR C-compilers. Some compiler specific details may,
however, need to be rewritten.
In the table below are listed the files that are relevant to the compiler project.
Table 4-1. Project files for CDC application (see IAR EW workspace file )
File
Type
cdc_task.c
C source code
cdc_task.h
Header file
main.c
C source code
main.h
Header file
power_drv.c
C source code
power_drv.h
Header file
scheduler.c
C source code
scheduler.h
Header file
start_boot.c
C source code
start_boot.h
Header file
time.c
C source code
time.h
Header file
Note
CDC task and CDC task init functions
Main program / Program entry point
Power management low level driver
Scheduler routines
Boot functions
Functions for timing
11
7801A-AVR-06/08
File
Type
cdc_task.c
C source code
cdc_task.h
Header file
main.c
C source code
main.h
Header file
uart_lib.c
C source code
uart_lib.h
Header file
uart_usb_lib.c
C source code
uart_usb_lib.h
Header file
usb_descriptor.c
C source code
usb_descriptor.h
Header file
usb_device_task.c
C source code
usb_device_task.h
Header file
usb_drv.c
C source code
usb_drv.h
Header file
usb_standard_request.c
C source code
usb_standard_request.h
Header file
usb_specific_request.c
C source code
usb_specific_request.h
Header file
usb_task.c
C source code
usb_task.h
Header file
Note
CDC task and CDC task init functions
Main program / Program entry point
This file provides a minimal VT100
terminal access
UART USB functions
USB parameters that identify the
application
USB device controller
USB driver routines
USB device enumeration requests
User call-back functions
Usb task and Usb init task functions
Table 4-2. Project files for battery module (see IAR EW workspace file )
12
File
Type
ADC.c
C source code
ADC.h
Header file
Batt_task.c
C source code
Batt_task.h
Header file
battery.c
C source code
battery.h
Header file
chargefunc.c
C source code
chargefunc.h
Header file
LIIONcharge.c
C source code
LIIONcharge.h
Header file
menu.c
C source code
menu.h
Header file
PWM.c
C source code
PWM.h
Header file
Note
Functions related to A/D converter
Batt task and Batt init task functions
Battery-specific definitions and
functions related to battery control &
data acquisition
Charge functions
Charge state function for Li-Ion
batteries
State machine definitions
Functions related to generating pulsewidth modulated output
AVR146
7801A-AVR-06/08
AVR146
File
Type
Note
statefunc.c
C source code
statefunc.h
Header file
Functions related to the states defined
in menu file
4.3 Overview
The firmware integrates all functions required to charge a lithium-ion battery.
Table 4-3. Memory requirements of firmware (IAR without optimization)
Build option
Debug
Memory
Approximate value
CODE (Flash)
13900 bytes
DATA (SRAM)
1109 bytes
XDATA (EEPROM)
2 bytes
4.4 State Machine
A state machine is implemented in battery task. This state machine is rather simple
and uses function pointers. It simply looks up the address of the next function to
execute and then jumps to that function. The flow chart of the state machine is
illustrated in the figure below.
Figure 4-2. Flow chart of main function, including the state machine
ADC measurements update
+
Uart state machine
Look up address for Current State
Jump to function of Current State
State function
Next State
Look up address for Next State
Set Current State = Next State
Upon return, the state machine expects the function to indicate the next state as a
return argument. The recognised return codes are described in the table below.
Table 4-4. State machine codes (see source code, menu.h)
Label
Related Function
Description
INIT
Initialize()
Entry state
BATCON
BatteryControl()
Check hardware and batteries
13
7801A-AVR-06/08
Label
Related Function
Description
PREQUAL
Charge()
Raise battery voltage, safety check
PREQUAL_CTRL
Charge()
Waiting end of PREQUAL
SLEEP
Sleep()
Low power consumption mode
CCURRENT
Charge()
Charge with constant current
CCURRENT_CTRL
Charge()
Waiting end of CCURRENT
CVOLTAGE
Charge()
Charge with constant voltage
CVOLTAGE_CTRL
Charge()
Waiting end of CVOLTAGE
ENDCHARGE
Charge()
End of successful charge
DISCHARGE
Discharge()
Go to BATCON state (ready for further
implementation)
ERROR
Error()
Resolve error, if possible
State functions are described in the following sections.
4.4.1 Initialize()
The initialisation function is the first state function that will be executed after device
reset. The flow chart of the function is shown in the figure below.
Figure 4-3. Flow chart of initialisation function
The initialisation function always exits with the same return code, pointing to the state
function for battery control.
4.4.2 BatteryControl()
The battery control function verifies that jumpers are set correctly and then checks to
see if there are any enabled batteries present that require charging. The program flow
is illustrated in the figure below.
14
AVR146
7801A-AVR-06/08
AVR146
Figure 4-4. Flow chart of battery control function
4.4.3 Charge()
The charge function contains the charging algorithm divided into stages. For this
application, it has four stages:
•
Prequalification - during which the battery is charged with a constant current
until a sufficient charge voltage is reached. If this happens within a given time
limit, the battery is considered good and the charger may continue on the
next stage. If time runs out before the voltage is reached, or battery
temperature goes out of limits, the battery is considered bad and charging is
halted.
•
Constant current charge - during which the battery is charged with a higher,
battery-specific current until the battery voltage reaches its maximum. If this
happens within the battery’s maximum charge time limit, the charger goes to
the next stage. If the time limit expires, or battery temperature goes out of
limits, the battery is considered bad and charging is halted.
•
Constant voltage charge – during which the battery is charged at the
maximum battery voltage until the charge current drops below a batteryspecific cut-off limit, or the maximum charge time limit expires. Here too,
charging is halted if battery temperature goes out of limits.
•
End charge – in which the charger decides whether to go into the sleep state,
or to attempt a charge of the other battery.
ChargeParameters and HaltParameters are key variables of this function. The
program flow of this state function is illustrated in the figure below.
15
7801A-AVR-06/08
Figure 4-5. Flow chart of the charge state function
Charge()
What is the current
state?
ST_PREQUAL
See Figure 4.6 for
ST_PREQUAL_CTRL
ST_CCURRENT_CTRL
ST_VOLTAGE_CTRL
ST_ENDCHARGE
ST_CCURRENT
ST_CVOLTAGE
Set charge current to the
defined prequalification
current.
(BAT_CURRENT_PREQUAL)
Set charge current to the
battery's maximum current.
(BattData.MaxCurrent)
Set charge voltage to the
defined maximum.
(BAT_VOLTAGE_MAX)
Stop PWM output.
Set ST_CCURRENT as the
next desired state.
Set ST_CVOLTAGE as the
next desired state.
Set ST_ENDCHARGE as the
next desired state.
Flag battery as charged.
Flag that charging should halt
once voltage reaches limit or
time runs out, and that timeout
means that battery is worn
out.
Set voltage limit to the defined
maximum.
(BAT_VOLTAGE_MAX)
Flag that charging should halt
once current sinks below limit,
or time runs out.
Is the other battery
enabled?
NO
YES
Set voltage limit to defined
prequalification voltage.
(BAT_VOLTAGE_PREQUAL)
Start charge timer with
the battery's maximum
charge time.
(BattData.MaxTime)
Set current limit to the
battery's cutoff limit.
(BattData.MinCurrent)
Set minimum and maximum
temperature to defined limits.
(BAT_TEMPERATURE_MIN
& MAX)
Next state is
ST_CCURRENT_CTRL
Next state is
ST_CVOLTAGE_CTRL
Set ST_BATCON as
next state.
Set ST_SLEEP as next
state.
Start PWM output.
Start charge timer with
defined limit.
(BAT_TIME_PREQUAL)
Next state is
ST_PREQUAL_CTRL
Return next state to
batt_task().
16
AVR146
7801A-AVR-06/08
AVR146
Figure 4-6. End of charge state function.
Charge()
ST_PREQUAL_CTRL
What is the current
state?
ST_CVOLTAGE_CTRL
ST_CCURRENT_CTRL
Call ConstantCurrent()
Call ConstantCurrent()
Call ConstantVoltage()
Return next state to
batt_task().
4.4.4 Discharge()
This function has not been implemented.
4.4.5 Sleep()
The application enters sleep mode when all batteries have been fully charged. It
wakes up at regular intervals to check the current status of the batteries. Sleep mode
is terminated as soon as any battery requires charging.
Sleep mode is illustrated in the flow chart below.
Figure 4-7. Flow chart of sleep function
17
7801A-AVR-06/08
4.4.6 Error()
Program flow is diverted here when an error has occurred. Program execution will exit
the error handler when all sources of error have been cleared.
The program flow is illustrated in the figure below.
Figure 4-8. Flow chart of error handler
4.5 Charging Control Functions
These functions are called by Charge() after all parameters have been set.
4.5.1 Constant Current/Voltage
These two functions are similar, apart from what ADC measurements they try to keep
within limits. Therefore, only the flow chart for ConstantCurrent() is illustrated in the
figure below. They both make use of the variable ChargeParameters.
18
AVR146
7801A-AVR-06/08
AVR146
Figure 5-3. Flow chart for ConstantCurrent()
ConstantCurrent()
Wait for ADC
conversions to
complete.
Charging of battery
inhibited?
YES
Current below
hysteresis?
YES
Increment PWM
duty cycle.
Drop PWM output to
zero.
NO
Stop timers.
Current above
hysteresis?
NO
YES
Decrement PWM
duty cycle.
NO
Were we stopped by
Master MCU
earlier?
YES
Remove flag that Master
MCU stopped the
charging.
HaltNow()
Start timers
again.
Return next state.
NO
19
7801A-AVR-06/08
4.5.2 Charge Halt Determination
Charge halt is determined by HaltNow(). This function is called by ConstantCurrent()
and ConstantVoltage() every time they loop, to decide if a stage of charging is done.
With the variable HaltParameters the user can specify at what terms the charging
should be halted, and if an error should be flagged if for example the time limit
expires. An error flag will also result in ST_ERROR being set as the next state,
thereby aborting the charge. If no errors are flagged, the next desired state, set earlier
in Charge(), will apply.
Lastly, the function checks if temperature is within limits, if the battery is OK and if
mains voltage is above minimum. Should any of these tests fail, the next state is set
to an appropriate error handler (ST_ERROR, ST_INIT or ST_SLEEP) and charging is
aborted.
20
AVR146
7801A-AVR-06/08
AVR146
Figure 5-4. Flow chart for HaltNow() part 1.
21
7801A-AVR-06/08
Figure 5-5. Flow chart for HaltNow() part 2
22
AVR146
7801A-AVR-06/08
AVR146
Figure 5-6. Flow chart for HaltNow() part 3
2
Halt on timeout?
YES
Charging timer run
out?
YES
Set Halt flag.
Flag battery as worn
out?
NO
YES
Stop PWM output.
Disable battery and flag
it as worn out.
NO
NO
Flag battery exhaustion
error and set
ST_ERROR as next
state.
3
23
7801A-AVR-06/08
Figure 5-7. Flow chart for HaltNow() part 4
3
Battery temperature
too cold or hot?
YES
Set Halt flag.
NO
Flag a battery
temperature error and
set ST_ERROR as next
state.
BatteryCheck() OK?
Is mains voltage
OK?
NO
NO
Stop PWM output.
Stop PWM output.
Set Halt flag.
Set Halt flag.
YES
Set ST_SLEEP as next
state.
Set ST_INIT as next
state.
Return Halt flag.
YES
4.6 Other Functions
4.6.1 A/D Conversion
The A/D converter uses the multiplexer to read in data from several channels. At the
end of a conversion the ADC Interrupt Service Routine (ISR) is called, as illustrated in
the flow chart below. After the ISR is complete program execution will return to
normal. For all MUX values, the ADC reference voltage is the 2.56V internal
reference.
24
AVR146
7801A-AVR-06/08
AVR146
Figure 5-8. Flow chart of ADC interrupt service routine
ADC_ISR()
Disable ADC interrupt
0b100011
MUX channel?
0b001001
0b100100
0b000000
3/ Save NTC reading
4/ Save RID reading
Set next MUX = 0b100100
Set next MUX = 0b001001
1/ Format and save IBAT
2/ Format and save VIN
ELSE
Update averaged IBAT
Update supple voltage flag
Update ADC flag
Set next MUX = 0b100011
Set Flag:
End of ADC loop
Set next MUX = 0b000000
Update MUX
Return from interrupt
4.7 Implementation
This section describes how to configure, create and download the software.
4.7.1 Configuration
The most important compile-time constants are discussed in the table below. See file
battery.h for more program constants.
25
7801A-AVR-06/08
Table 5-1. Battery-related compile-time constants (see source file battery.h)
26
Label
Description
CELL_VOLTAGE_SAFETY
In case unmatched batteries are to be charged, this constant
is subtracted from CELL_VOLTAGE_MAX for every extra cell
in the battery, ie. BAT_CELL_NUMBER – 1.
CELL_VOLTAGE_MAX
The voltage at which a cell should be charged.
CELL_VOLTAGE_LOW
The lowest voltage at which a cell is considered charged.
Charging will start when voltage drops below this level.
CELL_VOLTAGE_MIN
The lowest voltage at which charging may be initiated.
Should generally be set to the voltage limit under which
further discharge of batteries will cause damage.
CELL_VOLTAGE_PREQUAL
The voltage to which a cell should be charged to during
prequalification.
BAT_TEMPERATURE_MAX
The highest battery temperature allowed. Charging will stop /
not start if above this.
BAT_TEMPERATURE_MIN
The lowest battery temperature allowed. Charging will stop /
not start if below this.
BAT_CURRENT_PREQUAL
Charge current during prequalification mode.
BAT_CURRENT_HYST
Charge current hysteresis.
BAT_VOLTAGE_HYST
Charge voltage hysteresis.
BAT_VOLTAGE_PREQUAL
Target voltage during prequalification stage. If this voltage is
not achieved the battery will be marked as worn out.
BAT_TIME_PREQUAL
Maximum amount of time to spend in prequalification stage.
DEF_BAT_CAPACITY
Default battery capacity.
DEF_BAT_CURRENT_MAX
Default maximum charge current.
DEF_BAT_TIME_MAX
Default maximum charge time.
DEF_BAT_CURRENT_MIN
Default cut-off charge current.
ALLOW_NO_RID
If defined, batteries without RID (or not matching the lookuptable) will cause the charger to use the battery defaults.
Otherwise, charge is halted.
RID[ ].Low and RID[ ].High
Assume RID resistance match if value within these limits.
RID[ ].Capacity
Battery capacity for given RID.
RID[ ].Icharge
Charge current for given RID.
RID[ ].tCutOff
Maximum charge time for given RID.
RID[ ].IcutOff
Charge termination current for given RID.
NTC[ ]
Temperature look-up table.
AVR146
7801A-AVR-06/08
AVR146
4.7.2 Compilation
Both IAR and GCC project are available. The GCC project can use an external
makefile (see Makefile in \gcc\default) or use the options defined in AVR Studio
project.
Table 5-2. Compiler configuration
Section
Tab
Field
Processor
configuration
Target
General
Options
Linker
ATmega16/32U4
Memory
model
Small
Data stack
0x100
Return
address
stack
System
C/C++
Compiler
Value
32
Enable bit
definitions
…
None
Language
Require
prototypes
Selected
Output
Format
Extra
Options
Command
Line
Other: ubrof8
-y(CODE)
-Ointel-extended,(DATA)=$EXE_DIR$\$PROJ_FNAME$_data.hex
-Ointel-extended,(XDATA)=$EXE_DIR$\$PROJ_FNAME$_eeprom.hex
4.7.3 Programming
The compiled code is conveniently downloaded to the target device using
AVR Studio® and a debugger or programming tool of choice, such as the JTAGICE
mkII.
Note that the compiled code is ready to contain EEPROM data if needed. This feature
is only for further development. Answer OK when AVR Studio asks if EEPROM
contents should be loaded. This is illustrated in the figure below.
Figure 5-9. Loading initialised data to EEPROM
The program expects the use of the internal oscillator and that the clock signal is not
prescaled. Some fuse bits must be programmed to ensure proper program execution.
The fuse bit settings that deviate from the default factory configuration are listed in the
table below.
27
7801A-AVR-06/08
Table 5-3. Non-default fuse bit settings
Fuse Bit
Setting
Description
CKDIV8
1 (unprogrammed)
Do not divide clock by eight
CKSEL3…0
0010
Use internal oscillator
On the EVK527 Rev1.0.0, the JTAG pins and Joystick buttons share the same IOs. It
is the reason of the CDC key pressed application removal.
The HWB button is used to start the sending of data to the HyperTerminal.
After the download of software with AVR Studio, the ATmega16/32U4 bootloader is
erased. If a download is needed by using FLIP (ATMEL ISP), a download of
bootloader software (with AVR Studio) is needed.
28
AVR146
7801A-AVR-06/08
AVR146
5 EVK527 Rev1.0.0 Schematics
Figure 6-1. Page 1/5 (Schematics Rev3.0.0 corresponds to Board Rev1.0.0)
29
7801A-AVR-06/08
Figure 6-2. Page 2/5
30
AVR146
7801A-AVR-06/08
AVR146
Figure 6-3. Page 3/5
31
7801A-AVR-06/08
Figure 6-4. Page 4/5
32
AVR146
7801A-AVR-06/08
AVR146
Figure 6-5. Page 5/5
33
7801A-AVR-06/08
6 References
1. “What’s the best battery?”. Retrieved April 3, 2007, from Battery University:
http://www.batteryuniversity.com/partone-3.htm
2. “Lithium-ion safety concerns”. Retrieved April 3, 2007, from Battery University:
http://www.batteryuniversity.com/partone-5B.htm
3. “Charging lithium-ion batteries”. Retrieved April 3, 2007, from Battery University:
http://www.batteryuniversity.com/partone-12.htm
4. “VARTA™ EasyPack” datasheet:
550mAh
http://www2.vartamicrobattery.com/en/mb_data/documents/promotion_varta_easypack/688819.pdf
750mAh
http://www2.vartamicrobattery.com/en/mb_data/documents/promotion_varta_easypack/688820.pdf
1000mAh
http://www2.vartamicrobattery.com/en/mb_data/documents/promotion_varta_easypack/688821.pdf
2000mAh
http://www2.vartamicrobattery.com/en/mb_data/documents/promotion_varta_easypack/688822.pdf
5. “ATmega32U4”. Available from Atmel web site:
http://www.atmel.com/products/avr/
34
AVR146
7801A-AVR-06/08
Headquarters
International
Atmel Corporation
2325 Orchard Parkway
San Jose, CA 95131
USA
Tel: 1(408) 441-0311
Fax: 1(408) 487-2600
Atmel Asia
Room 1219
Chinachem Golden Plaza
77 Mody Road Tsimshatsui
East Kowloon
Hong Kong
Tel: (852) 2721-9778
Fax: (852) 2722-1369
Atmel Europe
Le Krebs
8, Rue Jean-Pierre Timbaud
BP 309
78054 Saint-Quentin-enYvelines Cedex
France
Tel: (33) 1-30-60-70-00
Fax: (33) 1-30-60-71-11
Atmel Japan
9F, Tonetsu Shinkawa Bldg.
1-24-8 Shinkawa
Chuo-ku, Tokyo 104-0033
Japan
Tel: (81) 3-3523-3551
Fax: (81) 3-3523-7581
Technical Support
[email protected]
Sales Contact
www.atmel.com/contacts
Product Contact
Web Site
www.atmel.com
Literature Request
www.atmel.com/literature
Disclaimer: The information in this document is provided in connection with Atmel products. No license, express or implied, by estoppel or otherwise, to any
intellectual property right is granted by this document or in connection with the sale of Atmel products. EXCEPT AS SET FORTH IN ATMEL’S TERMS AND
CONDITIONS OF SALE LOCATED ON ATMEL’S WEB SITE, ATMEL ASSUMES NO LIABILITY WHATSOEVER AND DISCLAIMS ANY EXPRESS, IMPLIED
OR STATUTORY WARRANTY RELATING TO ITS PRODUCTS INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT. IN NO EVENT SHALL ATMEL BE LIABLE FOR ANY DIRECT, INDIRECT,
CONSEQUENTIAL, PUNITIVE, SPECIAL OR INCIDENTAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS,
BUSINESS INTERRUPTION, OR LOSS OF INFORMATION) ARISING OUT OF THE USE OR INABILITY TO USE THIS DOCUMENT, EVEN IF ATMEL HAS
BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Atmel makes no representations or warranties with respect to the accuracy or completeness of the
contents of this document and reserves the right to make changes to specifications and product descriptions at any time without notice. Atmel does not make any
commitment to update the information contained herein. Unless specifically provided otherwise, Atmel products are not suitable for, and shall not be used in,
automotive applications. Atmel’s products are not intended, authorized, or warranted for use as components in applications intended to support or sustain life.
©2008 Atmel Corporation. All rights reserved. Atmel®, logo and combinations thereof, AVR®, AVR Studio® and others are registered
trademarks or trademarks of Atmel Corporation or its subsidiaries. Other terms and product names may be trademarks of others.
8080A-AVR-09/07