AT88SC6416C - Summary

Features
• One of a Family of Devices with User Memories from 1-Kbit to 256-Kbit
• 64-Kbit (8-Kbyte) EEPROM User Memory
⎯ Sixteen 512-byte (4-Kbit) Zones
⎯ Self-timed Write Cycle
⎯ Single Byte or 128-byte Page Write Mode
⎯ Programmable Access Rights for Each Zone
• 2-Kbit Configuration Zone
⎯ 37-byte OTP Area for User-defined Codes
⎯ 160-byte Area for User-defined Keys and Passwords
CryptoMemory
64 Kbit
• High Security Features
⎯ 64-bit Mutual Authentication Protocol (Under License of ELVA)
⎯ Encrypted Checksum
AT88SC6416C
⎯ Stream Encryption
⎯ Four Key Sets for Authentication and Encryption
⎯ Eight Sets of Two 24-bit Passwords
Summary
⎯ Anti-tearing Function
⎯ Voltage and Frequency Monitor
• Smart Card Features
⎯ ISO 7816 Class A (5V) or Class B (3V) Operation
⎯ ISO 7816-3 Asynchronous T = 0 Protocol (Gemplus® Patent) *
⎯ Supports Protocol and Parameters Selection for Faster Operation
⎯ Multiple Zones, Key Sets and Passwords for Multi-application Use
⎯ Synchronous 2-wire Serial Interface for Faster Device Initialization *
⎯ Programmable 8-byte Answer-To-Reset Register
⎯ ISO 7816-2 Compliant Modules
• Embedded Application Features
⎯ Low Voltage Operation: 2.7V to 5.5V
⎯ Secure Nonvolatile Storage for Sensitive System or User Information
⎯ 2-wire Serial Interface
⎯ 1.0 MHz Compatibility for Fast Operation
⎯ Standard 8-lead Plastic Packages, Green Compliant (exceeds RoHS)
⎯ Same Pinout as 2-wire Serial EEPROMs
• High Reliability
⎯ Endurance: 100,000 Cycles
⎯ Data Retention: 10 years
⎯ ESD Protection: 4,000V min
* Note: Modules available with either T=0 / 2-wire modes or 2-wire mode only.
5015KS–SMEM–08/09
Table 1. Pin Assignments
Pad
Description
ISO Module
TWI Module “SOIC PDIP”
VCC
Supply Voltage
C1
C1
8
GND
Ground
C5
C5
4
SCL/CLK Serial Clock Input
C3
C3
6
SDA/IO
Serial Data Input/Output
C7
C7
5
RST
Reset Input
C2
NC
NC
Figure 1.
Pin Configuration
ISO Smart Card Module
VCC=C1
RST=C2
SCL/CLK=C3
NC=C4
8-lead SOIC, PDIP
C5=GND
NC
1
8
VCC
C6=NC
NC
2
7
NC
NC
GND
3
6
4
5
SCL
SDA
C7=SDA/IO
C8=NC
TWI Smart Card Module
VCC=C1
NC=C2
SCL/CLK=C3
NC=C4
1.
C5=GND
C6=NC
C7=SDA/IO
C8=NC
Description
The AT88SC6416C member of the CryptoMemory® family is a high-performance secure memory providing 64 Kbits of
user memory with advanced security and cryptographic features built in. The user memory is divided into 16 512-byte
zones, each of which may be individually set with different security access rights or effectively combined together to
provide space for one to sixteen data files.
1.1.
Smart Card Applications
The AT88SC6416C provides high security, low cost, and ease of implementation without the need for a microprocessor
operating system. The embedded cryptographic engine provides for dynamic and symmetric mutual authentication
between the device and host, as well as performing stream encryption for all data and passwords exchanged between
the device and host. Up to four unique key sets may be used for these operations. The AT88SC6416C offers the ability
to communicate with virtually any smart card reader using the asynchronous T = 0 protocol (Gemplus Patent) defined
in ISO 7816-3. Communication speeds up to 153,600 baud are supported by utilizing ISO 7816-3 Protocol and
Parameter Selection.
1.2.
Embedded Applications
Through dynamic and symmetric mutual authentication, data encryption, and the use of encrypted checksums, the
AT88SC6416C provides a secure place for storage of sensitive information within a system. With its tamper detection
circuits, this information remains safe even under attack. A 2-wire serial interface running at 1.0 MHz is used for fast
and efficient communications with up to 15 devices that may be individually addressed. The AT88SC6416C is available
in industry standard 8-lead packages with the same familiar pinout as 2-wire serial EEPROMs.
2
AT88SC6416C
5015KS–SMEM–08/09
AT88SC6416C
Figure 2.
Block Diagram
VCC
GND
SCL/CLK
SDA/IO
Power
Management
Authentication,
Encryption and
Certification Unit
Synchronous
Interface
Data Transfer
Asynchronous
ISO Interface
Password
Verification
Reset Block
Answer to Reset
RST
2.
Pin Descriptions
2.1.
Supply Voltage (VCC)
Random
Generator
EEPROM
The VCC input is a 2.7V to 5.5V positive voltage supplied by the host.
2.2.
Clock (SCL/CLK)
In the asynchronous T = 0 protocol, the SCL/CLK input is used to provide the device with a carrier frequency f. The
nominal length of one bit emitted on I/O is defined as an “elementary time unit” (ETU) and is equal to 372/ f. When the
synchronous protocol is used, the SCL/CLK input is used to positive edge clock data into the device and negative edge
clock data out of the device.
2.3.
Reset (RST)
The AT88SC6416C provides an ISO 7816-3 compliant asynchronous answer to reset sequence. When the reset
sequence is activated, the device will output the data programmed into the 64-bit answer-to-reset register. An internal
pull-up on the RST input pad allows the device to be used in synchronous mode without bonding RST. The
AT88SC6416C does not support the synchronous answer-to-reset sequence.
2.4.
Serial Data (SDA/IO)
The SDA pin is bidirectional for serial data transfer. This pin is open-drain driven and may be wired with any number of
other open drain or open collector devices. An external pull-up resistor should be connected between SDA and VCC.
The value of this resistor and the system capacitance loading the SDA bus will determine the rise time of SDA. This
rise time will determine the maximum frequency during read operations. Low value pull-up resistors will allow higher
frequency operations while drawing higher average power. SDA/IO information applies to both asynchronous and
synchronous protocols.
When the synchronous protocol is used, the SCL/CLK input is used to positive edge clock data into the device and
negative edge clock data out of the device.
3
5015KS–SMEM–08/09
3.
*Absolute Maximum Ratings
Operating Temperature.............................−40°C to +85°C
*NOTICE:
Storage Temperature ............................−65°C to + 150°C
Voltage on Any Pin
with Respect to Ground .......................− 0.7 to VCC +0.7V
Maximum Operating Voltage.......................................6.0V
DC Output Current ..................................................5.0 mA
Table 2.
Stresses beyond those listed under “Absolute
Maximum Ratings” may cause permanent
damage to the device. This is a stress rating
only and functional operation of the device at
these or any other condition beyond those
indicated in the operational sections of this
specification is not implied. Exposure to
absolute maximum rating conditions for
extended periods of time may affect device
reliability.
DC Characteristics
Applicable over recommended operating range from VCC = +2.7 to 5.5V, TAC = -40°C to +85°C (unless otherwise noted)
Symbol
Parameter
Max
Units
5.5
V
Async READ at 3.57MHz
5
mA
Supply Current (VCC = 5.5V)
Async WRITE at 3.57MHz
5
mA
ICC
Supply Current (VCC = 5.5V)
Synch READ at 1MHz
5
mA
ICC
Supply Current (VCC = 5.5V)
Synch WRITE at 1MHz
5
mA
ISB
Standby Current (VCC = 5.5V)
VIN = VCC or GND
1
mA
VCC(2)
Supply Voltage
ICC
Supply Current (VCC = 5.5V)
ICC
Test Condition
Min
2.7
Typ
VIL
(1)
SDA/IO Input Low Threshold
0
VCC x 0.2
V
VIL
(1)
SCL/CLK Input Low Threshold
0
VCC x 0.2
V
VIL
(1)
RST Input Low Threshold
0
VCC x 0.2
V
VIH(1)(2)
SDA/IO Input High Threshold
VCC x 0.7
VCC
V
VIH(1)(2)
SCL/CLK Input High Threshold
VCC x 0.7
VCC
V
VIH(1)(2)
RST Input High Threshold
VCC x 0.7
VCC
V
IIL
SDA/IO Input Low Current
0 < VIL < VCC x 0.15
15
μA
IIL
SCL/CLK Input Low Current
0 < VIL < VCC x 0.15
15
μA
IIL
RST Input Low Current
0 < VIL < VCC x 0.15
50
μA
IIH
SDA/IO Input High Current
VCC x 0.7 < VIH < VCC
20
μA
IIH
SCL/CLK Input High Current
VCC x 0.7 < VIH < VCC
100
μA
IIH
RST Input High Current
VCC x 0.7 < VIH < VCC
150
μA
VOH
SDA/IO Output High Voltage
20K ohm external pull-up
VCC x 0.7
VCC
V
VOL
SDA/IO Output Low Voltage
IOL = 1mA
0
VCC x 0.15
V
IOH
SDA/IO Output High Current
VOH
20
μA
Notes: 1. VIL min and VIH max are reference only and are not tested.
2. To prevent Latch Up Conditions from occurring during Power Up of the AT88SCxxxxC, VCC must be turned
on before applying VIH. For Powering Down, VIH must be removed before turning VCC off.
4
AT88SC6416C
5015KS–SMEM–08/09
AT88SC6416C
Table 3.
AC Characteristics
Applicable over recommended operating range from VCC = +2.7 to 5.5V, TAC = -40°C to +85°C, CL = 30pF
(unless otherwise noted)
Symbol
4.
Parameter
Min
Max
Units
fCLK
Async Clock Frequency (VCC Range: +4.5 - 5.5V)
1
5
MHZ
fCLK
Async Clock Frequency (VCC Range: +2.7 - 3.3V)
1
4
MHZ
fCLK
Synch Clock Frequency
0
1
MHZ
Clock Duty cycle
40
60
%
tR
Rise Time - I/O, RST
1
μS
tF
Fall Time - I/O, RST
1
μS
tR
Rise Time – CLK
9% x period
μS
tF
Fall Time – CLK
9% x period
μS
tAA
Clock Low to Data Out Valid
35
nS
tHD.STA
Start Hold Time
200
nS
tSU.STA
Start Set-up Time
200
nS
tHD.DAT
Data In Hold Time
10
nS
tSU.DAT
Data In Set-up Time
100
nS
tSU.STO
Stop Set-up Time
200
nS
tDH
Data Out Hold Time
20
nS
tWR
Write Cycle Time (at 25°C)
5
mS
tWR
Write Cycle Time (-40° to +85°C)
7
mS
Device Operation for Synchronous Protocols
CLOCK and DATA TRANSITIONS: The SDA pin is normally pulled high with an external device. Data on the SDA pin
may change only during SCL low time periods (see Figure 5 on page 7). Data changes
during SCL high periods will indicate a start or stop condition as defined below.
START CONDITION:
A high-to-low transition of SDA with SCL high is a start condition which must precede any
other command (see Figure 6 on page 7).
STOP CONDITION:
A low-to-high transition of SDA with SCL high is a stop condition. After a read sequence, the
stop command will place the EEPROM in a standby power mode (see Figure 6 on page 7).
ACKNOWLEDGE:
All addresses and data words are serially transmitted to and from the EEPROM in 8-bit
words. The EEPROM sends a zero to acknowledge that it has received each word. This
happens during the ninth clock cycle.
MEMORY RESET:
After an interruption in protocol, power loss or system reset, any 2-wire part can be reset by
following these steps:
1.
2.
3.
Clock up to 9 cycles.
Look for SDA high in each cycle while SCL is high.
Create a start condition.
5
5015KS–SMEM–08/09
Figure 3.
Bus Timing for 2 wire communications: SCL: Serial Clock, SDA – Serial Data I/O
tHIGH
tF
tR
tLOW
SCL
tSU.STA
tLOW
tHD.STA
tHD.DAT
tSU.DAT
tSU.STO
SDA IN
tAA
tDH
tBUF
SDA OUT
Figure 4.
Write Cycle Timing: SCL: Serial Clock, SDA – Serial Data I/O
SCL
SDA
8th BIT
ACK
WORDn
twr
STOP
CONDITION
Note:
6
(1)
START
CONDITION
The write cycle time tWR is the time from a valid stop condition of a write sequence to the end of the internal
clear/write cycle.
AT88SC6416C
5015KS–SMEM–08/09
AT88SC6416C
Figure 5.
Data Validity
SDA
SCL
DATA STABLE
DATA STABLE
DATA
CHANGE
ALLOWED
Figure 6.
Start and Stop Definitions
SDA
SCL
START
Figure 7.
STOP
Output Acknowledge
1
SCL
8
9
DATA IN
DATA OUT
START
ACKNOWLEDGE
7
5015KS–SMEM–08/09
5.
Device Architecture
5.1.
User Zones
The EEPROM user memory is divided into 16 zones of 4,096 bits each. Multiple zones allow for different types of data
or files to be stored in different zones. Access to the user zones is allowed only after security requirements have been
met. These security requirements are defined by the user during the personalization of the device in the configuration
memory. If the same security requirements are selected for multiple zones, then these zones may effectively be
accessed as one larger zone.
Figure 8.
User Zones
Zone
$0
$1
$2
$3
$4
$5
$6
$7
$000
User 0
─
512 Bytes
─
$1F8
User 1
─
─
─
User 14
$000
─
─
$1F8
$000
User 15
─
512 Bytes
─
$1F8
6.
Control Logic
Access to the user zones occurs only through the control logic built into the device. This logic is configurable through
access registers, key registers and keys programmed into the configuration memory during device personalization.
Also implemented in the control logic is a cryptographic engine for performing the various higher-level security
functions of the device.
8
AT88SC6416C
5015KS–SMEM–08/09
AT88SC6416C
7.
Configuration Memory
The configuration memory consists of 2048 bits of EEPROM memory used for storing passwords, keys and codes and
for defining security levels to be used for each user zone. Access rights to the configuration memory are defined in the
control logic and may not be altered by the user.
Figure 9.
Configuration Memory
$0
$1
$2
$3
$08
$4
$5
$6
$7
Answer to Reset
$00
Fab Code
MTZ
Identification
Card Manufacturer Code
Lot History Code
$10
Read Only
$18
DCR
Identification Number Nc
$20
AR0
PR0
AR1
PR1
AR2
PR2
AR3
PR3
$28
AR4
PR4
AR5
PR5
AR6
PR6
AR7
PR7
$30
AR8
PR8
AR9
PR9
AR10
PR10
AR11
PR11
$38
AR12
PR12
AR13
PR13
AR14
PR14
AR15
PR15
$40
Access Control
Issuer Code
$48
$50
$58
$60
$68
For Authentication and Encryption use
Cryptography
For Authentication and Encryption use
Secret
$70
$78
$80
$88
$90
$98
$A0
$A8
$B0
PAC
Write 0
PAC
Read 0
$B8
PAC
Write 1
PAC
Read 1
$C0
PAC
Write 2
PAC
Read 2
$C8
PAC
Write 3
PAC
Read 3
$D0
PAC
Write 4
PAC
Read 4
$D8
PAC
Write 5
PAC
Read 5
$E0
PAC
Write 6
PAC
Read 6
$E8
PAC
Write 7
PAC
Read 7
$F0
Reserved
Password
Forbidden
$F8
9
5015KS–SMEM–08/09
8.
Security Fuses
There are three fuses on the device that must be blown during the device personalization process. Each fuse locks
certain portions of the configuration memory as OTP memory. Fuses are designed for the module manufacturer, card
manufacturer and card issuer and should be blown in sequence, although all programming of the device and blowing of
the fuses may be performed at one final step.
9.
Protocol Selection
The AT88SC6416C supports two different communication protocols.
Smart Card Applications: The asynchronous T = 0 protocol defined by ISO 7816-3 is used for compatibility with the
industry’s standard smart card readers.
Embedded Applications: A 2-wire serial interface is used for fast and efficient communication with logic or controllers.
The power-up sequence determines which of the two communication protocols will be used.
9.1.
Asynchronous T = 0 Protocol
This power-up sequence complies with ISO 7816-3 for a cold reset in smart card applications.
•
•
•
•
VCC goes high; RST, I/O-SDA and CLK-SCL are low.
Set I/O-SDA in receive mode.
Provide a clock signal to CLK-SCL.
RST goes high after 400 clock cycles.
The device will respond with a 64-bit ATR code, including historical bytes to indicate the memory density within the
CryptoMemory family. Once the asynchronous mode has been selected, it is not possible to switch to the synchronous
mode without powering off the device.
Figure 10.
Asynchronous T = 0 Protocol (Gemplus Patent)
Vcc
I/O-SDA
ATR
RST
CLK-SCL
After a successful ATR, the Protocol and Parameter Selection (PPS) protocol, as defined by ISO 7816-3, may be used
to negotiate the communications speed with CryptoMemory devices 32 Kbits and larger. CryptoMemory supports
D values of 1, 2, 4, 8, 12, and 16 for an F value of 372. Also supported are D values of 8 and 16 for F = 512. This
allows selection of 8 communications speeds ranging from 9600 baud to 153,600 baud.
10
AT88SC6416C
5015KS–SMEM–08/09
AT88SC6416C
9.2.
Synchronous 2-wire Serial Interface
The synchronous mode is the default after powering up VCC due to an internal pull-up on RST. For embedded
applications using CryptoMemory in standard plastic packages, this is the only communication protocol.
• Power-up VCC, RST goes high also.
• After stable VCC, CLK-SCL and I/O-SDA may be driven.
Figure 11.
Synchronous 2-wire Protocol
Vcc
I/O-SDA
RST
1
CLK-SCL
4
3
5
Five clock pulses must be sent before the first command is issued.
Note:
10.
2
Communication Security Modes
Communications between the device and host operate in three basic modes. Standard mode is the default mode for
the device after power-up. Authentication mode is activated by a successful authentication sequence. Encryption mode
is activated by a successful encryption activation following a successful authentication.
Table 4.
Communication Security Modes
Mode
(1)
Configuration Data
User Data
Passwords
Data Integrity Check
Standard
Clear
clear
clear
MDC
Authentication
Clear
clear
encrypted
MAC
Encryption
Clear
encrypted
encrypted
MAC
Note:
1. Configuration data include viewable areas of the Configuration Zone except the passwords:
MDC: Modification Detection Code
MAC: Message Authentication Code.
11
5015KS–SMEM–08/09
11.
Security Options
11.1.
Anti-tearing
In the event of a power loss during a write cycle, the integrity of the device’s stored data may be recovered. This
function is optional: the host may choose to activate the anti-tearing function, depending on application requirements.
When anti-tearing is active, write commands take longer to execute, since more write cycles are required to complete
them, and data are limited to eight bytes.
Data are written first to a buffer zone in EEPROM instead of the intended destination address, but with the same
access conditions. The data are then written in the required location. If this second write cycle is interrupted due to a
power loss, the device will automatically recover the data from the system buffer zone at the next power-up.
In 2-wire mode, the host is required to perform ACK polling for up to 8 ms after write commands when anti-tearing is
active. At power-up, the host is required to perform ACK polling, in some cases for up to 2 ms, in the event that the
device needs to carry out the data recovery process.
11.2.
Write Lock
If a user zone is configured in the write lock mode, the lowest address byte of an 8-byte page constitutes a write access
byte for the bytes of that page.
Example
The write lock byte at $080 controls the bytes from $080 to $087.
Figure 12.
Write Lock Example
Address
$0
$1
$2
$3
$4
$5
$6
$7
$080
11011001
xxxx xxxx
xxxx xxxx
xxxx xxxx
xxxx xxxx
xxxx xxxx
xxxx xxxx
xxxx xxxx
locked
locked
locked
The write lock byte may also be locked by writing its least significant (rightmost) bit to “0”. Moreover, when write lock
mode is activated, the write lock byte can only be programmed – that is, bits written to “0” cannot return to “1”.
In the write lock configuration, only one byte can be written at a time. Even if several bytes are received, only the first
byte will be taken into account by the device.
12
AT88SC6416C
5015KS–SMEM–08/09
AT88SC6416C
12.
Password Verification
Passwords may be used to protect read and/or write access of any user zone. When a valid password is presented, it
is memorized and active until power is turned off, unless a new password is presented or RST becomes active. There
are eight password sets that may be used to protect any user zone. Only one password is active at a time, but write
passwords give read access also.
12.1.
Authentication Protocol
The access to a user zone may be protected by an authentication protocol. Any one of four keys may be selected to
use with a user zone.
The authentication success is memorized and active as long as the chip is powered, unless a new authentication is
initialized or RST becomes active. If the new authentication request is not validated, the card loses its previous
authentication and it should be presented again. Only the last request is memorized.
Note:
Password and authentication may be presented at any time and in any order. If the trials limit has been
reached (after four consecutive incorrect attempts), the password verification or authentication process will not
be taken into account.
Figure 13.
Password and Authentication Operations
Device (Card)
Card Number
Host (Reader)
AUTHENTICATION
VERIFY A
COMPUTE Challenge B
COMPUTE Challenge A
Challenge A
Challenge B
VERIFY B
READ ACCESS
VERIFY RPW
DATA
Checksum (CS)
VERIFY WPW
VERIFY CS
Read Password (RPW)
VERIFY CS
WRITE ACCESS
Write Password (WPW)
DATA
CS
Write DATA
13
5015KS–SMEM–08/09
12.2.
Checksum
The AT88SC6416C implements a data validity check function in the form of a checksum, which may function in
standard, authentication or encryption modes.
In the standard mode, the checksum is implemented as a Modification Detection Code (MDC), in which the host may
read a MDC from the device in order to verify that the data sent was received correctly.
In the authentication and encryption modes, the checksum becomes more powerful since it provides a bidirectional
data integrity check and data origin authentication capability in the form of a Message Authentication Code (MAC).
Only the host/device that carried out a valid authentication is capable of computing a valid MAC. While operating in the
authentication or encryption modes, the use of a MAC is required. For an ongoing command, if the device calculates a
MAC different from the MAC transmitted by the host, not only is the command abandoned but the mode is also reset. A
new authentication and/or encryption activation will be required to reactivate the MAC.
12.3.
Encryption
The data exchanged between the device and the host during read, write and verify password commands may be
encrypted to ensure data confidentiality.
The issuer may choose to require encryption for a user zone by settings made in the configuration memory. Any one of
four keys may be selected for use with a user zone. In this case, activation of the encryption mode is required in order
to read/write data in the zone and only encrypted data will be transmitted. Even if not required, the host may elect to
activate encryption provided the proper keys are known.
12.4.
Supervisor Mode
Enabling this feature allows the holder of one specific password to gain full access to all eight password sets, including
the ability to change passwords.
12.5.
Modify Forbidden
No write access is allowed in a user zone protected with this feature at any time. The user zone must be written during
device personalization prior to blowing the security fuses.
12.6.
Program Only
For a user zone protected by this feature, data within the zone may be changed from a “1” to a “0”, but never from a “0”
to a “1”.
13.
Initial Device Programming
To enable the security features of CryptoMemory, the device must first be personalized to set up several registers and
load in the appropriate passwords and keys. This is accomplished through programming the configuration memory of
CryptoMemory using simple write and read commands. To gain access to the configuration memory, the secure code
must first be successfully presented. For the AT88SC6416C device, the secure code is $F7 62 0B. After writing and
verifying data in the configuration memory, the security fuses must be blown to lock this information in the device. For
additional information on personalizing CryptoMemory, please see the application notes Programming CryptoMemory
for Embedded Applications and Initializing CryptoMemory for Smart Card Applications (at www.Atmel.com).
14
AT88SC6416C
5015KS–SMEM–08/09
AT88SC6416C
14.
Ordering Information
Ordering Code
Package
Voltage Range
Temperature Range
AT88SC6416C-MJ
AT88SC6416C-MJTG
M2 – J Module - ISO
M2 – J Module - TWI
2.7V–5.5V
Commercial (0°C–70°C)
AT88SC6416C-PU
AT88SC6416C-SU
8P3
8S1
2.7V–5.5V
Green compliant (exceeds
RoHS)/Industrial (−40°C–85°C)
AT88SC6416C-WI
7 mil wafer
2.7V–5.5V
Industrial (−40°C–85°C)
Package Type(1) (2)
Description
M2 – J Module : ISO or TWI
M2 ISO 7816 Smart Card Module
8P3
8-lead, 0.300” Wide, Plastic Dual Inline Package (PDIP)
8S1
8-lead, 0.150” Wide, Plastic Gull Wing Small Outline Package (JEDEC SOIC)
Note:
1. Formal drawings may be obtained from an Atmel sales office.
2. The J Module Package is used for either ISO (T=0 / 2-wire mode) or TWI (2-wire mode only).
15
5015KS–SMEM–08/09
15.
Packaging Information
Ordering Code: MJ or MJTG
Module Size: M2
Dimension*: 12.6 x 11.4 [mm]
Glob Top:
Round - ∅ 8.5 [mm]
Thickness: 0.58 [mm]
Pitch:
14.25 mm
*Note:
16
The module dimensions listed refer to the dimensions of the exposed metal contact area. The actual
dimensions of the module after excise or punching from the carrier tape are generally 0.4 mm greater in both
directions (i.e., a punched M2 module will yield 13.0 x 11.8 mm).
AT88SC6416C
5015KS–SMEM–08/09
AT88SC6416C
15.1.
Ordering Code: SU
8S1 – JEDEC SOIC
C
1
E
E1
N
L
Top View
End View
e
COMMON DIMENSIONS
(Unit of Measure = mm)
b
A
SYMBOL
A1
D
MIN
MAX
A
1.35
–
1.75
A1
0.10
–
0.25
b
0.31
–
0.51
C
0.17
–
0.25
D
4.80
–
5.05
E1
3.81
–
3.99
E
5.79
–
6.20
e
Side View
NOM
L
NOTE
1.27 BSC
0.40
–
1.27
0˚
–
8˚
Note: These drawings are for general information only. Refer to JEDEC Drawing MS-012, Variation AA for proper dimensions,
tolerances, datums, etc.
3/17/05
1150 E. Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906
TITLE
8S1, 8-lead (0.150" Wide Body), Plastic Gull Wing
Small Outline (JEDEC SOIC)
DRAWING NO.
REV.
8S1
C
17
5015KS–SMEM–08/09
15.2.
Ordering Code: PU
8P3 – PDIP
E
1
E1
N
Top View
c
eA
End View
D
D1
COMMON DIMENSIONS
(Unit of Measure = inches)
e
A2 A
b2
b3
b
4 PLCS
Side View
L
MIN
NOM
MAX
NOTE
A
−
−
0.210
2
A2
0.115
0.130
0.195
b
0.014
0.018
0.022
5
b2
0.045
0.060
0.070
6
b3
0.030
0.039
0.045
6
c
0.008
0.010
0.014
D
0.355
0.365
0.400
3
D1
0.005
−
−
3
E
0.300
0.310
0.325
4
E1
0.240
0.250
0.280
3
SYMBOL
e
0.100 BSC
eA
L
4
0.300 BSC
0.115
0.130
0.150
2
Notes: 1. This drawing is for general information only; refer to JEDEC Drawing MS-001, Variation BA, for additional
information.
2. Dimensions A and L are measured with the package seated in JEDEC seating plane Gauge GS-3.
3. D, D1 and E1 dimensions do not include mold Flash or protrusions. Mold Flash or protrusions shall not
exceed 0.010 inch.
4. E and eA measured with the leads constrained to be perpendicular to datum.
5. Pointed or rounded lead tips are preferred to ease insertion.
6. b2 and b3 maximum dimensions do not include Dambar protrusions. Dambar protrusions shall not exceed
0.010 (0.25 mm).
R
18
2325 Orchard Parkway
San Jose, CA 95131
TITLE
8P3, 8-lead, 0.300" Wide Body, Plastic Dual
In-line Package (PDIP)
01/09/02
DRAWING NO.
REV.
8P3
B
AT88SC6416C
5015KS–SMEM–08/09
AT88SC6416C
Appendix A. Revision History
Doc. Rev.
Date
Comments
5015KS
08/2009
Updated TWI module informaiton
5015JS
08/2009
Updated pin assignments and configuration figure
Added note under features
Updated Absolute Maximum Ratings
Ordering code, package type and note updated
Packaging Information – added “or MJTG”
5015JS
02/2009
Features Section – add ‘Green compliant (exceeds RoHS) to end of ‘Standard 8-lead
Plastic Packages’ bullet.
Added Note to DC Characteristics table and applied to VCC and all 3 instances of VIH
symbols in table.
Ordering Information page: Add ‘Green compliant (exceeds RoHS) to middle row of
Temperature Range
Replace ‘Lead-free/Halogen-free. Keep industrial
Updated to 2009 Copyright.
5015IS
01/2009
Removed P module offering.
5015HS
11/2008
Updated timing diagrams.
5015GS
04/2007
Final release version.
5015GS
03/2007
Implemented revision history.
Removed Industrial package offerings.
Removed 8Y4 package offering.
Replaced User Zone, Configuration Memory, and Write Lock
Example tables with new information.
19
5015KS–SMEM–08/09
Headquarters
International
Atmel Corporation
2325 Orchard Parkway
San Jose, CA 95131
USA
Tel: 1(408) 441-0311
Fax: 1(408) 487-2600
Atmel Asia
Unit 1-5 & 16, 19/F
BEA Tower, Millennium City 5
418 Kwun Tong Road
Kwun Tong, Kowloon
Hong Kong
Tel: (852) 2245-6100
Fax: (852) 2722-1369
Atmel Europe
Le Krebs
8, Rue Jean-Pierre Timbaud
BP 309
78054 Saint-Quentin-enYvelines Cedex
France
Tel: (33) 1-30-60-70-00
Fax: (33) 1-30-60-71-11
Atmel Japan
9F, Tonetsu Shinkawa Bldg.
1-24-8 Shinkawa
Chuo-ku, Tokyo 104-0033
Japan
Tel: (81) 3-3523-3551
Fax: (81) 3-3523-7581
Technical Support
[email protected]
Sales Contact
www.atmel.com/contacts
Product Contact
Web Site
www.atmel.com
Literature Requests
www.atmel.com/literature
Disclaimer: The information in this document is provided in connection with Atmel products. No license, express or implied, by estoppel or otherwise, to any
intellectual property right is granted by this document or in connection with the sale of Atmel products. EXCEPT AS SET FORTH IN ATMEL’S TERMS AND
CONDITIONS OF SALE LOCATED ON ATMEL’S WEB SITE, ATMEL ASSUMES NO LIABILITY WHATSOEVER AND DISCLAIMS ANY EXPRESS, IMPLIED
OR STATUTORY WARRANTY RELATING TO ITS PRODUCTS INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT. IN NO EVENT SHALL ATMEL BE LIABLE FOR ANY DIRECT, INDIRECT,
CONSEQUENTIAL, PUNITIVE, SPECIAL OR INCIDEN-TAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS
INTERRUPTION, OR LOSS OF INFORMATION) ARISING OUT OF THE USE OR INABILITY TO USE THIS DOCUMENT, EVEN IF ATMEL HAS BEEN ADVISED
OF THE POSSIBILITY OF SUCH DAMAGES. Atmel makes no representations or warranties with respect to the accuracy or completeness of the contents of this
document and reserves the right to make changes to specifications and product descriptions at any time without notice. Atmel does not make any commitment to
update the information contained herein. Unless specifically provided otherwise, Atmel products are not suitable for, and shall not be used in, automotive
applications. Atmel’s products are not intended, authorized, or warranted for use as components in applications intended to support or sustain life.
© 2009 Atmel Corporation. All rights reserved. Atmel®, Atmel logo and combinations thereof, CryptoMemory® and others, are registered trademarks or
trademarks of Atmel Corporation or its subsidiaries. Other terms and product names may be trademarks of others.
5015KS–SMEM–08/09