Active Errata List • Power-down Mode Current Out of Specification in ROMless Mode • Power-fail Threshold Out of Specification • TWI Data Transmission in Slave Transmitter Mode Errata History Lot Number Errata List All lot numbers affected 1, 3 All TSC8725G2D EPROM devices are affected 2 8051 Microcontrollers Errata Description 1. Power-down Mode Current Out of Specification in ROMless Mode IPD is out of specification when EA pin is tied to a low level. The ROMless products and EPROM and ROM products used as ROMless (EA = 0) are consuming extra current in power-down mode. Table 1 below shows the power-down current maximum value and specification for high speed in low voltage versions. TS80C251G2D TS83C251G2D TS87C251G2D Table 1. DC Characteristics – TA = -40 to +85°C Symbol Parameter Max Spec Max Value Units IPD Power-down Current 20 35 µA IPD Power-down Current 10 20 µA Test Conditions Errata Sheet VRET < VDD < 5.5V VRET < VDD < 3.6V Workaround None. 2. Power-fail Threshold Out of Specification The tolerance on the power-fail reset voltage threshold is out of specification. The device may never exit reset at power-up when power-fail reset is enabled. Workaround Some devices may need a higher voltage to exit reset. The RSTD bit has to be set in POWM register to disable the Power-fail Reset detector before the voltage is reduced. 3. Two-wire Interface Data Transmission in Slave Transmitter Mode When in slave transmitter mode, if the slave transmits data starting with a low level on the bus (MSB is logic 0), data set-up time is not respected and leads to a bus error. Workaround The workaround proposed consists in removing the set-up violation by stretching the SDA line (P1.7) when the MSB of the data to transmit is logic 0. This workaround must be implemented in states A8h, B0h, and B8h when data is written to the serial data register (SSDAT). Rev. 4179B–8051–10/02 In assembler the workaround is: mov A,data ;read data to transmit mov SSDAT, A ;load transmit buffer jb ACC.7,Msb_tst ;test MSB clr SDA ;stretch data line (P1.7) to low level Msb_tst:mov setb SSCON,#40h ;or 44h: clear SSI flag SDA ;data line is now driven by controller In C language, the workaround is: SSDAT = data; //load translit buffer if(!(data&0x80)) //test MSB { SDA = 0; //stretch data line (P1.7) to low level } 2 SSCON = 0x40; //or 0x44: clear SSI flag SDA = 1; //data line is now driven by controller TSC8x251G2D Errata Sheet 4179B–8051–10/02 Atmel Headquarters Atmel Operations Corporate Headquarters Memory 2325 Orchard Parkway San Jose, CA 95131 TEL 1(408) 441-0311 FAX 1(408) 487-2600 Europe Atmel Sarl Route des Arsenaux 41 Case Postale 80 CH-1705 Fribourg Switzerland TEL (41) 26-426-5555 FAX (41) 26-426-5500 Asia Room 1219 Chinachem Golden Plaza 77 Mody Road Tsimhatsui East Kowloon Hong Kong TEL (852) 2721-9778 FAX (852) 2722-1369 Japan 9F, Tonetsu Shinkawa Bldg. 1-24-8 Shinkawa Chuo-ku, Tokyo 104-0033 Japan TEL (81) 3-3523-3551 FAX (81) 3-3523-7581 2325 Orchard Parkway San Jose, CA 95131 TEL 1(408) 441-0311 FAX 1(408) 436-4314 RF/Automotive Theresienstrasse 2 Postfach 3535 74025 Heilbronn, Germany TEL (49) 71-31-67-0 FAX (49) 71-31-67-2340 Microcontrollers 2325 Orchard Parkway San Jose, CA 95131 TEL 1(408) 441-0311 FAX 1(408) 436-4314 La Chantrerie BP 70602 44306 Nantes Cedex 3, France TEL (33) 2-40-18-18-18 FAX (33) 2-40-18-19-60 ASIC/ASSP/Smart Cards Zone Industrielle 13106 Rousset Cedex, France TEL (33) 4-42-53-60-00 FAX (33) 4-42-53-60-01 1150 East Cheyenne Mtn. Blvd. Colorado Springs, CO 80906 TEL 1(719) 576-3300 FAX 1(719) 540-1759 Biometrics/Imaging/Hi-Rel MPU/ High Speed Converters/RF Datacom Avenue de Rochepleine BP 123 38521 Saint-Egreve Cedex, France TEL (33) 4-76-58-30-00 FAX (33) 4-76-58-34-80 1150 East Cheyenne Mtn. Blvd. Colorado Springs, CO 80906 TEL 1(719) 576-3300 FAX 1(719) 540-1759 Scottish Enterprise Technology Park Maxwell Building East Kilbride G75 0QR, Scotland TEL (44) 1355-803-000 FAX (44) 1355-242-743 e-mail [email protected] Web Site http://www.atmel.com © Atmel Corporation 2002. Atmel Corporation makes no warranty for the use of its products, other than those expressly contained in the Company’s standard warranty which is detailed in Atmel’s Terms and Conditions located on the Company’s web site. The Company assumes no responsibility for any errors which may appear in this document, reserves the right to change devices or specifications detailed herein at any time without notice, and does not make any commitment to update the information contained herein. No licenses to patents or other intellectual property of Atmel are granted by the Company in connection with the sale of Atmel products, expressly or by implication. Atmel’s products are not authorized for use as critical components in life support devices or systems. ATMEL ® is a registered trademark of Atmel. Other terms and product names may be the trademarks of others. Printed on recycled paper. 4179B–8051–10/02 /xM