TSC8x251G2D - Errata

Active Errata List
•
Power-down Mode Current Out of Specification in ROMless Mode
•
Power-fail Threshold Out of Specification
•
TWI Data Transmission in Slave Transmitter Mode
Errata History
Lot Number
Errata List
All lot numbers affected
1, 3
All TSC8725G2D EPROM devices are affected
2
8051
Microcontrollers
Errata Description
1.
Power-down Mode Current Out of Specification in ROMless Mode
IPD is out of specification when EA pin is tied to a low level. The ROMless products
and EPROM and ROM products used as ROMless (EA = 0) are consuming extra
current in power-down mode. Table 1 below shows the power-down current maximum value and specification for high speed in low voltage versions.
TS80C251G2D
TS83C251G2D
TS87C251G2D
Table 1. DC Characteristics – TA = -40 to +85°C
Symbol
Parameter
Max Spec
Max Value
Units
IPD
Power-down
Current
20
35
µA
IPD
Power-down
Current
10
20
µA
Test Conditions
Errata Sheet
VRET < VDD < 5.5V
VRET < VDD < 3.6V
Workaround
None.
2.
Power-fail Threshold Out of Specification
The tolerance on the power-fail reset voltage threshold is out of specification. The
device may never exit reset at power-up when power-fail reset is enabled.
Workaround
Some devices may need a higher voltage to exit reset. The RSTD bit has to be set
in POWM register to disable the Power-fail Reset detector before the voltage is
reduced.
3.
Two-wire Interface Data Transmission in Slave Transmitter Mode
When in slave transmitter mode, if the slave transmits data starting with a low
level on the bus (MSB is logic 0), data set-up time is not respected and leads to a
bus error.
Workaround
The workaround proposed consists in removing the set-up violation by stretching
the SDA line (P1.7) when the MSB of the data to transmit is logic 0. This
workaround must be implemented in states A8h, B0h, and B8h when data is written to the serial data register (SSDAT).
Rev. 4179B–8051–10/02
In assembler the workaround is:
mov
A,data
;read data to transmit
mov
SSDAT, A
;load transmit buffer
jb
ACC.7,Msb_tst
;test MSB
clr
SDA
;stretch data line (P1.7) to low level
Msb_tst:mov
setb
SSCON,#40h
;or 44h: clear SSI flag
SDA
;data line is now driven by controller
In C language, the workaround is:
SSDAT = data;
//load translit buffer
if(!(data&0x80))
//test MSB
{
SDA = 0;
//stretch data line (P1.7) to low level
}
2
SSCON = 0x40;
//or 0x44: clear SSI flag
SDA = 1;
//data line is now driven by controller
TSC8x251G2D Errata Sheet
4179B–8051–10/02
Atmel Headquarters
Atmel Operations
Corporate Headquarters
Memory
2325 Orchard Parkway
San Jose, CA 95131
TEL 1(408) 441-0311
FAX 1(408) 487-2600
Europe
Atmel Sarl
Route des Arsenaux 41
Case Postale 80
CH-1705 Fribourg
Switzerland
TEL (41) 26-426-5555
FAX (41) 26-426-5500
Asia
Room 1219
Chinachem Golden Plaza
77 Mody Road Tsimhatsui
East Kowloon
Hong Kong
TEL (852) 2721-9778
FAX (852) 2722-1369
Japan
9F, Tonetsu Shinkawa Bldg.
1-24-8 Shinkawa
Chuo-ku, Tokyo 104-0033
Japan
TEL (81) 3-3523-3551
FAX (81) 3-3523-7581
2325 Orchard Parkway
San Jose, CA 95131
TEL 1(408) 441-0311
FAX 1(408) 436-4314
RF/Automotive
Theresienstrasse 2
Postfach 3535
74025 Heilbronn, Germany
TEL (49) 71-31-67-0
FAX (49) 71-31-67-2340
Microcontrollers
2325 Orchard Parkway
San Jose, CA 95131
TEL 1(408) 441-0311
FAX 1(408) 436-4314
La Chantrerie
BP 70602
44306 Nantes Cedex 3, France
TEL (33) 2-40-18-18-18
FAX (33) 2-40-18-19-60
ASIC/ASSP/Smart Cards
Zone Industrielle
13106 Rousset Cedex, France
TEL (33) 4-42-53-60-00
FAX (33) 4-42-53-60-01
1150 East Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906
TEL 1(719) 576-3300
FAX 1(719) 540-1759
Biometrics/Imaging/Hi-Rel MPU/
High Speed Converters/RF Datacom
Avenue de Rochepleine
BP 123
38521 Saint-Egreve Cedex, France
TEL (33) 4-76-58-30-00
FAX (33) 4-76-58-34-80
1150 East Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906
TEL 1(719) 576-3300
FAX 1(719) 540-1759
Scottish Enterprise Technology Park
Maxwell Building
East Kilbride G75 0QR, Scotland
TEL (44) 1355-803-000
FAX (44) 1355-242-743
e-mail
[email protected]
Web Site
http://www.atmel.com
© Atmel Corporation 2002.
Atmel Corporation makes no warranty for the use of its products, other than those expressly contained in the Company’s standard warranty
which is detailed in Atmel’s Terms and Conditions located on the Company’s web site. The Company assumes no responsibility for any errors
which may appear in this document, reserves the right to change devices or specifications detailed herein at any time without notice, and does
not make any commitment to update the information contained herein. No licenses to patents or other intellectual property of Atmel are granted
by the Company in connection with the sale of Atmel products, expressly or by implication. Atmel’s products are not authorized for use as critical
components in life support devices or systems.
ATMEL ® is a registered trademark of Atmel.
Other terms and product names may be the trademarks of others.
Printed on recycled paper.
4179B–8051–10/02
/xM