Data Sheet

PRELIMINARY
XCBC2246A
1710-2690 vs 3300-6000 Cross-Band Combiner
Preliminary Rev A – Revision Date: October 27, 2015
Features
• Low Insertion Loss
• Low Ripple
• Wide passband response
Description
0.2”x0.4” surface-mount cross-band
combiner. Developed for use in
infrastructure applications.
Filter complies with RoHS standards.
Electrical Specifications
Parameter
Low Band Response
Passband IL
Passband Return Loss
Attenuation
High Band Response
Passband IL
Passband Return Loss
Attenuation
Nominal Impedance
Power in any port
Power in any port
Power out of common port
Power out of common port
Frequency
MHz
Typical
@ 25ºC
Specification
@ 25ºC
Spec over
-40ºC to +85ºC
380 - 2200
2200 - 2500
2500 - 2690
380 - 2690
3300 - 6000
-0.3
-0.7
-1.0
-18.0
-21.0
-0.5
-0.9
-1.2
-16.0
-20.0
-0.6
-0.9
-1.2
-16.0
-20.0
3300 - 3400
3400-3500
3500-3800
3800-4900
4900-6000
3300 - 6000
380 - 2690
-1.0
-0.7
?
?
-0.3
-18.0
-21.0
50 Ω
-1.2
-0.9
?
?
-0.5
-16.0
-20.0
-1.2
-0.9
?
?
-0.6
-16.0
-20.0
Average
Peak
Average
Peak
3 Watt max
30 Watt max
6 Watt max
60 Watt max
Note: Supplier shall test each filter to the critical electrical specifications of the above table. Any subsequent audits may deviate from in value due to measurement
repeatability among different test systems. Such deviations shall not exceed the following limits:
Specification Allowance
Insertion Loss
0.1 dB
Return Loss
1.0 dB
Stopbands
1.0 dB
Page 1 of 2
PRELIMINARY
XCBC2246A
1710-2690 vs 3300-6000 Cross-Band Combiner
Preliminary Rev A – Revision Date: October 27, 2015
Mechanical Drawing
Electrical Response
Pin Assignments
and PCB Layout
Page 2 of 2