PRELIMINARY XCBC2246A 1710-2690 vs 3300-6000 Cross-Band Combiner Preliminary Rev A – Revision Date: October 27, 2015 Features • Low Insertion Loss • Low Ripple • Wide passband response Description 0.2”x0.4” surface-mount cross-band combiner. Developed for use in infrastructure applications. Filter complies with RoHS standards. Electrical Specifications Parameter Low Band Response Passband IL Passband Return Loss Attenuation High Band Response Passband IL Passband Return Loss Attenuation Nominal Impedance Power in any port Power in any port Power out of common port Power out of common port Frequency MHz Typical @ 25ºC Specification @ 25ºC Spec over -40ºC to +85ºC 380 - 2200 2200 - 2500 2500 - 2690 380 - 2690 3300 - 6000 -0.3 -0.7 -1.0 -18.0 -21.0 -0.5 -0.9 -1.2 -16.0 -20.0 -0.6 -0.9 -1.2 -16.0 -20.0 3300 - 3400 3400-3500 3500-3800 3800-4900 4900-6000 3300 - 6000 380 - 2690 -1.0 -0.7 ? ? -0.3 -18.0 -21.0 50 Ω -1.2 -0.9 ? ? -0.5 -16.0 -20.0 -1.2 -0.9 ? ? -0.6 -16.0 -20.0 Average Peak Average Peak 3 Watt max 30 Watt max 6 Watt max 60 Watt max Note: Supplier shall test each filter to the critical electrical specifications of the above table. Any subsequent audits may deviate from in value due to measurement repeatability among different test systems. Such deviations shall not exceed the following limits: Specification Allowance Insertion Loss 0.1 dB Return Loss 1.0 dB Stopbands 1.0 dB Page 1 of 2 PRELIMINARY XCBC2246A 1710-2690 vs 3300-6000 Cross-Band Combiner Preliminary Rev A – Revision Date: October 27, 2015 Mechanical Drawing Electrical Response Pin Assignments and PCB Layout Page 2 of 2