FEATURES










Clipped Sine Output
Optional Voltage Control for Frequency Tuning [VCTCXO]
7.0mmx5.0mm Surface Mount Package
Frequency Range 5 – 52 MHz
Fundamental Crystal Design
Operating Voltage, +3.0Vdc, +3.3Vdc or +5.0Vdc
Overall Frequency Stability ±4.6ppm
Operating Temperature to -40°C to +85°C
Tape & Reel Packaging Standard, EIA-418
RoHS/Green Compliant [6/6]
APPLICATIONS
The Model 578, a quartz based analog TCXO with Clipped Sine output and optional frequency tuning, is suitable for
applications requiring Stratum 3 performance such as base stations, Microcells, Femtocells, 1588 and Synchronous
Ethernet timing, wireless communications, test and measurement.
ORDERING INFORMATION
578
SUPPLY VOLTAGE
R = +3.0Vdc
L = +3.3Vdc
S = +5.0Vdc
PACKAGING OPTIONS
T - 1k pcs./reel
FREQUENCY TUNING [AFC]
FREQUENCY
T = No AFC [TCXO]
A = ±5ppm - ±8ppm [VCTCXO]
Product Frequency Code [3 digits]
Refer to document 016-1454-0,
Frequency Code Tables.
OPERATING TEMPERATURE RANGE
C = -20°C to +70°C
I = -40°C to +85°C
Not all performance combinations and frequencies may be available.
Contact your local CTS Representative or CTS Customer Service for availability.
PACKAGING INFORMATION [reference]
Device quantity is 1k pcs. maximum per 180mm reel.
17.5
4.0
8.0
Ø1.50
1.75
2.40
2.10
2.0
Ø13
120°
16.0
8.40
7.90
Ø60
5.70
5.40
DIRECTION OF FEED
Ø180
Ø23
Dimensions in Millimeters
Dimensions in Millimeters
Document No. 008-0344-0
Page 1 - 3
www.ctscorp.com
Rev. B
Model 578
Stratum 3 TCXO/VC-TCXO – Clipped Sine
ELECTRICAL PARAMETERS
ELECTRICAL CHARACTERISTICS
PARAMETER
Maximum Supply Voltage
Maximum Control Voltage
Storage Temperature
Operating Temperature
Order Code 'C'
Order Code 'I'
Frequency Range
Supply Voltage
Order Code 'R'
Order Code 'L'
Order Code 'S'
Supply Current
Frequency Stability
Overall Frequency Stability
vs. Initial Calibration
vs. Operating Temperature
vs. Supply Voltage
vs. Load
vs. Aging
Holdover
Control Voltage
Frequency Tuning [VCTCXO Only]
VC Input Impedance
Output Waveform
Output Voltage Levels
Output Load
Output Duty Cycle
Start Up Time
Enable Function
Enable Input Voltage
Disable Input Voltage
Phase Noise
1
SYMBOL
VC C
VC
T S TG
CONDITIONS
-
MIN
-0.6
-0.5
-40
TA
-
fO
-
-20
-40
5
VC C
±5%
IC C
∆f/fO
∆f/f25
∆f/fO
VC
ZVC
RL // CL
SYM
TS
VIH
VIL
-
Reference to fO , Including 20 years aging
@ +25°C, at time of shipment
[Fmax. - Fmin.]/2, over -40°C to +85°C
±5% change @ +25°C
±5% change
20 years @ +40°C
[Fmax. - Fmin.]/2, over 24 hours
VC = 1.5V ±1.0V, monotonic positive
AC coupled Clipped Sinewave
TYP
-
MAX
6.0
VC C
+100
UNIT
V
V
°C
°C
-
+70
+85
52
2.85
3.14
4.75
-
3.0
3.3
5.0
-
3.15
3.47
5.25
3.5
-
-
4.60
1.00
0.28
0.40
0.10
2.80
0.37
0.5
1.5
5-8
2.5
100
-
-
+25
MHz
V
mA
± ppm
V
± ppm
kOhm
-
0.8
10kOhm // 10pF
-
45
-
-
55
2
%
ms
0.7*VC C
-
-
0.3*VC C
V
@ 50% Level
Pin 8 Logic '1', Output Enabled
Pin 8 Logic '0', Output Disabled [High Imp]
-
Vp-p
dBc/Hz
Notes:
1. Phase Noise performance may vary based on output frequency. See example plot at 10 MHz below.
Document No. 008-0344-0
Page 2 - 3
Rev. B
Model 578
Stratum 3 TCXO/VC-TCXO – Clipped Sine
MECHANICAL SPECIFICATIONS
MARKING INFORMATION
1. M578 – CTS Model Series.
2. ● – Pin 1 identifier.
3. C – CTS identifier.4.
4. D – Date code. See Table II for codes.
5. xxx – Frequency Code.
Refer to document 016-1454-0, Frequency Code Tables.
PACKAGE DRAWING
M578
● CDXXX
NOTES
1. DO NOT make connections to non-labeled pins.
Castellation pins may have internal connections
used in the manufacturing process.
2. Termination pads (e4); barrier plating is nickel
[Ni] with gold [Au] flash plate.
3. Reflow conditions per JEDEC J-STD-020,
260°C maximum.
4. MSL = 1.
SUGGESTED SOLDER PAD GEOMETRY
D.U.T. PIN ASSIGNMENTS
PIN
4
5
8
9
SYMBOL
GND
Output
EOH
VCC
10
VC
DESCRIPTION
Circuit & Package Ground
Clipped Sine Wave Output
Tri-State Enable
Supply Voltage
Control Voltage – VCTCXO [Note 1]
GND - TCXO
NOTES
1. Connect to ground for TCXO [no AFC] option.
2. DC-Cut Capacitor Required.
Add 1000pF capacitor between TCXO output and input of load.
TEST CIRCUIT – CLIPPED SINE LOAD
TABLE II – DATE CODE
MONTH
JAN
YEAR
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
DEC
M
2001
2005
2009
2013
2017
A
B
C
D
E
F
G
H
J
K
L
2002
2006
2010
2014
2018
N
P
Q
R
S
T
U
V
W
X
Y
Z
2003
2007
2011
2015
2019
a
b
c
d
e
f
g
h
j
k
l
m
2004
2008
2012
2016
2020
n
p
q
r
s
t
u
v
w
x
y
z
Document No. 008-0344-0
Page 3 - 3
Rev. B