Machine Interface NA Series Bringing technology to life 2 Bringing technology to life - NA Series, Machine Interface Sysmac - the family that matches every requirement An HMI that is dynamic, intuitive and predictive makes industrial machines more attractive and competitive. The Omron HMI enables faster, more efficient control and monitoring - and a more natural, proactive relationship between operator and machine. The design has been based on real applications and customer requirements, a future-proofed, scalable platform that will evolve with their ever-changing needs, allowing real time reaction to events. As part of the system family, the NA Series is fully aware of the total machine. • • • • Proactive operator/ machine relationship Design based on real applications and customer requirements Future-proof, scalable platform Allows quick reaction 3 NX I/O NX Safety FH Vision System G5 servo system NJ/NX Machine Automation Controller 4 Bringing technology to life - NA Series, Machine Interface Integrating your world Sysmac Studio is the centrepiece of the Sysmac Platform, bringing together all areas of automation including: logic, motion, vision, safety and now visualisation. The NA series machine interface brings you a clear view in one integrated project. ONE Tag Database • S hare NJ/NX Variables (Tags) in the machine interface application. “Intelli sense” makes it FAST • F lexible programming with variables including union and enumeration variables • D efine/use NA data structures in the machine interface application 5 ONE Learning, ONE Project • Program your controller and safety systems • Simultaneously program the NA Series as device in Sysmac Studio • Program your whole machine in one project • Work in a familiar way on all devices Safe and secure • Configure individual users with multi access levels SIMPLE • Clearly and quickly define the View • Quickly change properties, animations, events and actions • Powerful page editor to group objects • Rotate, and resize - all with a simple click BUT STILL FLEXIBLE • Write your Visual Basic Script • Extend the possibilities with Visual Basic Test it in ONE • Integrated testing through simulation of motion, logic and visualisation at the same time • Build confidence before having a single piece of hardware • Test your machine interface with the NJ/NX Control program via the Simulator in Sysmac Studio Features for speed • Structured programming (through One software) • Network device insight • Vision setup • Machine Controller troubleshooting 6 Bringing technology to life - NA Series, Machine Interface Insight & security maximised ... The NA series has full security and authentication features that keep your valuable assets secure at all times. And if something unexpected does happen, in your machine you will be able to solve the problem quickly and prevent a reoccurrence. Remote access • You can view and operate the HMI installed at production sites from your tablet using Ethernet or WiFi. • The access of remote devices can be managed and limited. This helps prevent accidental operation and information leakage, while securing accessibility. Access permission client Device A Access permitted Device B Access permitted Device C Unauthorized access prohibited Two devices (A, B) are accessing. Increased security The NA Series can be configured to specific staff, with multi access levels with password protection. This ensures authorised people interact with the machine. Protecting your assets • Your project can be passwordprotected along with other applications (Control and Safety). • Transferring data can be protected (disable overwrite or theft). 7 ... downtime minimised You can present a machine view that is understandable at a glance. The NA Series brings everything together through rich media including PDF, video, and data to provide an intuitive and proactive machine management tool. Show your manual in a movie Imagine actually showing how to perform certain procedures. With the NA Series you have a trained engineer at the operator’s side, 24x7. Show PDFs You can use whatever visual assets you already have to illustrate how to do things. Error occurs NJ/NX troubleshooter Error details can be checked. Check the controller The troubleshooter allows you to monitor and release the NJ/NX Controller errors/events as well as the userdefined errors/events. 8 Bringing technology to life - NA Series, Machine Interface Simple, but Flexible! The NA Series gives the user the ability to design using IAGs (Intelligent Application Gadgets). IAGs simplify and accelerate the development process through structuring the project and enhancing reuse. From simple graphics to complex objects, you can make your own collections and share them between projects, like a Function Block. Step 1: Machine Parts, the Visual Using standard controls, or graphics from the machine parts collection, design your own IAG. Add interface properties and methods to bring the object to life when reused. 1 myTemperature mySpeed RunMotor(Boolean bStatus) ‘IAG Code behind - Add local subroutines for the IAG. Public Function RunMotor(bStatus As Boolean) As Double ‘start motor at default speed mySpeed = 50 ‘return current speed RunMotor = 50 End Function Public Function IncreaseSpeed(nIncrement As Integer) As Double ‘ Increase speed by increment if < 1000 If mySpeed + nIncrement < 1000 Then mySpeed = mySpeed + nIncrement Else ‘Otherwise set to top speed mySpeed = 1000 End If ‘Return new speed IncreaseSpeed = mySpeed End Function Step 2: Extensible with Visual Basic As well as many graphic IAGs, it is also possible to embed code within an IAG. The code can extend the possibilities of the gadget such as providing special device communication. Thanks to Visual Basic the standard functionality of the NA can be extended as required. 2 9 Step 3: Publish and Share When the IAG is built and tested (using simulation) it can be published and the collection file distributed to be used again and again. Omron will release further IAG collections to extend the functionality of the NA Series. 3 10 Bringing technology to life - NA Series, Machine Interface A range of options that covers every need All wide screen models: 7, 9, 12, 15 inch Black and Silver Edge to edge design Sysmac cut-out design RUN indicator Function keys Resistive touch screen, single touch ...ideal for environments where operators wear gloves and water proof is needed 1 2 3 4 5 6 1 USB slave (Tool port) 4 2 Ethernet ports, one for factory one for office network 2 2x USB 5 SD Card slot 3 1 Serial * 6 24V DC * The serial port is for future expansion. 11 NJ/NX Series Sysmac Studio CJ Series (FINS & CIP) 2x Ethernet USB 2.0: 2x Host 1x Slave Ethernet USB Keyboard Mouse USB Memory Sysmac Studio • High speed communications network • Broad choice of connection possibilities • USB cable detachable without changing the hardware • Water and dust proof design 12 Bringing technology to life - NA Series, Machine Interface SHOW your machine - Greater visualization Vector graphics DXF files are supported to display CAD data. Even if the drawing is enlarged or reduced in size, it never loses quality. Supported format: DXF Still smooth even if enlarged! Indirect reference of text strings A text string that is displayed on a label object (1 line) or a text box object (1 or more lines) can be switched by indirect reference. The machine operating status and alarm details can be easily displayed. Set a variable for the ID to switch the group in the properties. Register a new resource group. When the ID is specified by the variable, the text string is displayed according to the ID. Tab control A part of the screen can be used like a notepad. Up to 64 tab pages for a Tab Control object can be created, and up to 10 Tab Control objects can be placed on a screen. Change a tab page instead of a screen to monitor/ change various data. Touch Tab Page1 is displayed. 13 Broken-line graphs Data of variables and multidimensional arrays in the controller can be displayed as broken-line graphs. Broken-line graphs can also be created from the data in the CSV files saved in the SD card inserted in the NJ Controller by using subroutines (Visual Basic). You can specify the display range of large array data, such as operation log, by setting the offset value. This increases the compatibility with the controller. Multidimensional array The offset can be specified from the start of the display range. Graph display range CSV Scaling Scaling can be set for Data Display/Data Edit objects and global variables. Values of variables can be converted by specifying conversion expressions, which makes it easy to show data in the controller. Without scaling 10,000,000ns Scaling by specifying 1/100,000,000 Value of NJ variable: 10,000,000 0.1 seconds 14 Bringing technology to life - NA Series, Machine Interface OPERATE your machine - Comfortable to use Supporting Asian languages An Asian language - Japanese, simplified Chinese, traditional Chinese, or Korean - can be selected to use in the keypad of the NA Series. The keypad language changes automatically when the language is changed in the language settings. Local languages can be used to input the names of products when new recipes of the food packaging machine are added. Japanese Traditional Chinese Simplified Chinese Korean Touch The keypad is displayed in the language set in System Languages in the Sysmac Studio. Executing a subroutine with multiple threads Some subroutines require time due to repeated processing or waiting time. Even such a subroutine can be executed during screen update, without affecting operability and visibility. From Subroutine XX Dim I as Integer Dim Val as Integer =0 For i=0 to 100000 Val=i Next This process is repeated 100,000 times. To For i=0 to 100000 Val=i Next The screen is not updated while the subroutine is executed until the loop is completed. For i=0 to 100000 Val=i Next The subroutine is executed in parts while the screen is updated. For i=0 to 100000 Val=i Next The subroutine is executed in parts while the screen is updated. 15 Custom keypads You can change the keypad size, choose only the keys you need, and customize the keys to execute specified actions. Create your own keypad suitable for your applications. Changing the keypad size Creating user's own keypad The size can be changed to suit the user's needs. Only the keys the user needs can be chosen, and the keys to execute specified actions can be customized. Page jump from user alarm The page to switch can be specified in each alarm setting. When an alarm occurs, you can check the troubleshooter screen by selecting the displayed alarm. The page to switch can be specified in each alarm setting. The specified page is displayed. Select the alarm and then click the Page Jump Button. 16 Bringing technology to life - NA Series, Machine Interface Usability - Simple screen design Importing external device variables External device variables can be imported from an XLSX or CXT file. The CJ variable files and Excel files containing edited variables can be imported. Imported variables facilitate programming including external device settings. Import a file XLSX CXT Cross references The same GUI cross reference function as the NJ/NX Controller can be used. When the variable to search is clicked in the global variable table, a list of the locations where the variable is used is displayed in the Cross Reference Tab Page. You can access the object or subroutine where the variable is used by clicking the location, which makes screen design and debugging quicker and easier. Click the variable in the global variable table to show a list of the locations where the variable is used in the Cross Reference Tab Page. Click the location to access the object where the variable is used. 17 Search and Replace You can search and replace text strings in all subroutines (Visual Basic), objects, and variables within a project. It is quick and easy to edit and debug variable names and switch labels. 1) Enter a text string to search/replace Display the object to search/replace 2) Start to search/replace 3) The results are displayed Text editing You can edit a label either directly on the Page Editor or in its properties. Editing in the object properties is recommended to edit the ON and OFF labels and change the font attributes at the same time. Direct text editing on the Page Editor Easy to edit the ON and OFF labels in the properties of the object Select objects Change the attributes of all objects at once In the properties, the font attributes (font type, size, and color) of multiple labels can be changed at the same time. Data input order The Data input order can be set. When numeric values are entered consecutively, the focus automatically moves to the next Data Edit object by touching the Enter key. Input errors and input time can be minimized. Enable AutoNavigateKeypads in the properties of the page to enter data consecutively. The Data input order can be set in the property of the Data Edit object. The focus automatically moves to the next object by touching the Enter key. 18 Bringing technology to life - NA Series, Machine Interface Watch Tab Page The same GUI as the NJ/NX Controller is used. Register the variable to monitor/change and then change its value on the Watch Tab Page to easily debug screens with the NA Simulator without the physical HMI. (Broken-line Graph and Trend Graph objects cannot be used for simulations.) Change to TRUE Check the alarm with the Simulator Displaying object status The ON/OFF status of the object placed on the Page Editor can be switched. You can check the ON/OFF status of a Lamp or other object without starting the Simulator. Not only the ON/OFF status of a Bit Lamp object but also all status of a Data Lamp object can be checked. Switch between ON and OFF. Change the status of the Data Lamp object. 19 NA screen capture The screens displayed on the NA Series can be captured and saved in the SD card inserted in the NA Series or the USB memory connected to the NA Series. • When a screen of the NA Series is required to create a machine operation manual • When the current screen is required to save as proof of a trouble Supported format: PNG The combination of VNC and FTP allows you to capture the NA screens from the connected PC. FZ-MEM2G Sysmac Studio printing Project information including screens and properties can be printed from the Sysmac Studio. This function is useful when you create machine manuals. You can select items to print. Screens, events, and properties can be printed. Programmable Terminal NA series Bringing technology to life 15.4 inch wide The NA-series Programmable Terminal transforms machine data into information, shows information and controls devices based on requirements at FA manufacturing sites. 9 inch wide The NA Series, together with the NJ/NX-series Machine Automation Controller and the Automation Software Sysmac Studio, allows you to simply and flexibly create sophisticated user interfaces to suit your machines. 12.1 inch wide 7 inch wide Features • • • • • Widescreen in all models: 7, 9, 12, and 15 inches More than 16 million color display for all models and 1280 x 800 high resolution display for the 12 and 15-inch models Multimedia including video and PDF 2 Ethernet ports capable of simultaneous access from both the control device and maintenance segments by separating the segments Sysmac Studio providing an Integrated Development Environment NJ/NX variables sharing in the NA project and NA application testing with the NJ/NX program via the Simulator to reduce development time • Many security features including operation authority settings and execution restrictions with IDs • Microsoft Visual Basic for versatile, flexible and advanced programming Sysmac is a trademark or registered trademark of OMRON Corporation in Japan and other countries for OMRON factory automation products. Windows, Visual Basic, Word, Excel are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. EtherCAT® is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. EtherNet/IPTM is the trademarks of ODVA. Other company names and product names in this document are the trademarks or registered trademarks of their respective companies. The product photographs and figures that are used in this catalog may vary somewhat from the actual products. Microsoft product screen shot(s) reprinted with permission from Microsoft Corporation. 20 NA series System configuration USB slave Serial port * USB host ✕ 2 Ethernet Ethernet SD Memory port 2 port 1 Card SD Card NJ/NX series Ethernet Ethernet (CIP/FINS) CJ series Connect to the Ethernet port 2 on the NA Sysmac Studio Mouse USB Memory Keyboard Sysmac Studio * The serial port is for future expansion. 21 NA series Ordering Information NA5-@W Product name NA5-15W NA5-12W NA5-9W NA5-7W High-pressure Waterproof Attachment for NA5-@W Specifications Model 15.4 inch wide screen, TFT LCD, 16,770,000 colors (24 bit full color), 1280 ✕ 800 dots, Frame color : Silver NA5-15W101S 15.4 inch wide screen, TFT LCD, 16,770,000 colors (24 bit full color), 1280 ✕ 800 dots, Frame color : Black NA5-15W101B 12.1 inch wide screen, TFT LCD, 16,770,000 colors (24 bit full color), 1280 ✕ 800 dots, Frame color : Silver NA5-12W101S 12.1 inch wide screen, TFT LCD, 16,770,000 colors (24 bit full color), 1280 ✕ 800 dots, Frame color : Black NA5-12W101B 9 inch wide screen, TFT LCD, 16,770,000 colors (24 bit full color), 800 ✕ 480 dots, Frame color : Silver NA5-9W001S 9 inch wide screen, TFT LCD, 16,770,000 colors (24 bit full color), 800 ✕ 480 dots, Frame color : Black NA5-9W001B 7 inch wide screen, TFT LCD, 16,770,000 colors (24 bit full color), 800 ✕ 480 dots, Frame color : Silver NA5-7W001S 7 inch wide screen, TFT LCD, 16,770,000 colors (24 bit full color), 800 ✕ 480 dots, Frame color : Black NA5-7W001B NA-15WATW01 This metal frame is for high-pressure waterproofing. Install it to conform to UL Type 4X standards. UL Type 4X is the rating for high-pressure wash-down applications with a flow rate of 246 liter/min. This attachment can be used for the NA5-@W, but not for the NA5-@U. NA-12WATW01 NA-9WATW01 NA-7WATW01 Note: The NA5-@U is also available. Contact your OMRON representative for details. Options Product name SD memory card USB Memory Replacement Battery Anti-reflection Sheets Specifications Model 2 GB HMC-SD291 4 GB HMC-SD491 2 GB FZ-MEM2G 8 GB FZ-MEM8G Battery life: 5 years (at 25°C). This Battery is provided as an accessory. CJ1W-BAT01 For the NA5-15W. Attach a Sheet to the screen to protect against diffused reflections and dirt. The entire Sheet is colorless and transparent. Five Sheets are provided in one set. NA-15WKBA04 For the NA5-12W. Attach a Sheet to the screen to protect against diffused reflections and dirt. The entire Sheet is colorless and transparent. Five Sheets are provided in one set. NA-12WKBA04 For the NA5-9W. Attach a Sheet to the screen to protect against diffused reflections and dirt. The entire Sheet is colorless and transparent. Five Sheets are provided in one set. NA-9WKBA04 For the NA5-7W. Attach a Sheet to the screen to protect against diffused reflections and dirt. The entire Sheet is colorless and transparent. Five Sheets are provided in one set. NA-7WKBA04 Automation Software Product name Sysmac Studio Standard Edition Ver.1.@@ Number of licenses Specifications The Sysmac Studio is the software that provides an integrated environment for setting, programming, debugging and maintenance of machine automation controllers including the NJ/NX Series, EtherCAT Slave, and the HMI. Sysmac Studio runs on the following OS. Windows XP (Service Pack 3 or higher, 32-bit version) / Windows Vista (32-bit version) / Windows 7 (32-bit/64-bit version) / Windows 8 (32-bit/64-bit version) / Windows 8.1 (32-bit/64-bit version) − (Media only) Media DVD 1 license SYSMAC-SE200D SYSMAC-SE201L 3 licenses 10 licenses Model SYSMAC-SE203L − SYSMAC-SE210L 30 licenses SYSMAC-SE230L 50 licenses SYSMAC-SE250L Note: Site licenses are available for users who will run Sysmac Studio on multiple computers. Ask your OMRON sales representative for details. USB Cable Product name USB Cable 22 Specifications Use commercially available USB cable. Specifications: USB 2.0 cable (A connector - B connector), 5.0 m max. NA series Recommended Network Devices Industrial Switching Hubs Specifications Product name Industrial Switching Hubs Functions Quality of Service (QoS): EtherNet/IP control data priority Failure detection: Broadcast storm and LSI error detection 10/100BASE-TX, Auto-Negotiation No. of ports Failure detection 3 No 5 No 5 Yes Current consumption (A) Accessories Power supply connector • Power supply connector • Connector for informing error Model 0.22 W4S1-03B 0.22 W4S1-05B 0.22 W4S1-05C Recommended Ethernet Communications Cables Use STP (shielded twisted-pair) cable of category 5 or higher Product name Wire Gauge and Number of Pairs: AWG24, 4-pair Cable Recommended manufacturer Cables NETSTAR-C5E SAB 0.5 ✕ 4P Kuramo Electric Co. KETH-SB SWCC Showa Cable Systems Co. FAE-5004 Panduit Corporation MPS588 Cables Fujikura Ltd. F-LINK-E 0.5mm ✕ 4P RJ45 Connectors Panduit Corporation MPS588 RJ45 Connectors Wire Gauge and Number of Pairs: 0.5 mm, 4-pair Cable Model Hitachi Metals, Ltd Note: We recommend you to use above cable and RJ45 Connectors together. 23 NA series Performance Specifications NA5-@W and NA5-@U have the same specifications and performance characteristics of hardware and software. Display Specification Item Display panel *1 Backlight *2 NA5-15W NA5-12W Display device TFT LCD Screen size 15.4 inches Resolution 1,280 × 800 dots (horizontal ✕ vertical) Colors 16,770,000 colors (24 bit full colors) Effective display area 331 × 207 mm (horizontal ✕ vertical) View angles Left: 60°, Right: 60°, Top: 60°, Bottom: 60° Life 50,000 hours min. *3 Brightness adjustment 200 levels Front panel indicators *4 RUN 12.1 inches Lit green: Normal operation Model 9.0 inches Standard range Number of light and dark pixels: 10 or less. (There must not be 3 consecutive light/dark pixels.) NA5-7W 7.0 inches 800 × 480 dots (horizontal ✕ vertical) 261 × 163 mm (horizontal ✕ vertical) *1. There may be some defective pixels in the display. This is not a fault as long as the numbers of defective light and dark pixels fall within the following standard ranges. NA5-15W NA5-12W NA5-9W NA5-7W NA5-9W 197 × 118 mm (horizontal ✕ vertical) 152 × 91 mm (horizontal ✕ vertical) Lit red: Error *2. The backlight can be replaced at an OMRON maintenance base. *3. This is the estimated time before brightness is reduced by half at room temperature and humidity. The life expectancy is drastically shortened if Programmable Terminal is used at high temperatures. *4. The brightness of the front panel indicators is also adjustable when you adjust the brightness of the backlight. Operation Specification Item NA5-15W NA5-12W NA5-9W NA5-7W Method: Analog resistance membrane (pressure sensitive) Resolution: 16,384 ✕ 16,384 Touch panel Life: 1,000,000 operations Function keys * 3 inputs (capacitance inputs) * Each function key has blue indicator. The brightness of the function key indicators is also adjustable when you adjust the brightness of the backlight. Data Capacity Specification Item User data capacity NA5-15W NA5-12W NA5-9W NA5-7W 256 MB External Interfaces Item Ethernet ports USB host ports USB slave port Serial port * SD Memory Card slot Expansion Unit connector * Specifications (Same for all models.) Applications Port 1: Connecting to anything other than the Sysmac Studio, e.g., device connections and VNC clients Port 2: Connecting to the Sysmac Studio in addition to the applications of port 1. Number of ports 2 ports Compliant standards IEEE 802.3i (10BASE-T), IEEE 802.3u (100BASE-TX), and IEEE 802.3ab (1000Base-T) Transmission media Shielded twisted-pair (STP) cable: Category 5, 5e, or higher Transmission distance 100 m Connector RJ-45 8P8C modular connector Applications USB Memory Device, keyboard, or mouse Number of ports 2 ports Compliant standards USB 2.0 Transmission distance 5 m max. Connector Type-A connector Applications Sysmac Studio connection Number of ports 1 port Compliant standards USB 2.0 Transmission distance 5 m max. Connector Type-B connector Applications Device Connection Number of ports 1 port Compliant standards RS-232C Transmission distance 15 m max. Connector D-DUB 9-pin female connector Applications To transfer or store the project or to store log data. Number of slots 1 slot Compliant standards SD/SDHC Applications Expansion Unit Quantity 1 * The serial port and Expansion Unit connector are for future expansion. 24 NA series General Specifications Specification Item NA5-15W NA5-12W NA5-9W NA5-7W Rated supply voltage 24 VDC Allowable power supply voltage range 19.2 to 28.8 VDC (24 VDC ±20%) Allowable momentary power interruption time Operation for momentary power interruption is not specified. Power consumption 47 W max. Ambient operating temperature 0 to 50°C *1 *2 Ambient storage temperature −20 to +60°C *3 Ambient operating humidity 10 to 90% *2 Must be no condensation. Atmosphere Must be free from corrosive gases. Pollution degree 2 or less: JIS B 3502, IEC 61131-2 Noise immunity 2 kV on power supply line (Conforms to IEC 61000-4-4.) Vibration resistance (during operation) Conforms to IEC 60068-2-6. 5 to 8.4 Hz with 3.5 mm half amplitude and 8.4 to 150 Hz with 9.8 m/s2 for 100 minutes each in X,Y, and Z directions (Time coefficient of 10 minutes ✕ coefficient factor of 10 = total time of 100 min.) Shock resistance (during operation) Conforms to IEC 60028-2-27. 147 m/s2 3 times each in X, Y, and Z directions Dimensions 420 ✕ 291 ✕ 69 mm (W ✕ H ✕ D) 340 ✕ 244 ✕ 69 mm (W ✕ H ✕ D) 290 ✕ 190 ✕ 69 mm (W ✕ H ✕ D) 236 ✕ 165 ✕ 69 mm (W ✕ H ✕ D) Panel cutout dimensions 392 0 ✕ 268 0 mm (horizontal ✕ vertical) Panel thickness: 1.6 to 6.0 mm *4 310 0 ✕ 221 0 mm (horizontal ✕ vertical) Panel thickness: 1.6 to 6.0 mm *4 261 0 ✕ 166 0 mm (horizontal ✕ vertical) Panel thickness: 1.6 to 6.0 mm *4 197 0 ✕ 141 0 mm (horizontal ✕ vertical) Panel thickness: 1.6 to 6.0 mm *4 Weight 3.2 kg max. 2.3 kg max. 1.7 kg max. 1.3 kg max. Degree of protection Front-panel controls: IP65 oil-proof type, UL Type 4X (at initial state) To reinstall the NA Unit in a panel, contact your OMRON representative for replacement of the rubber packing. Battery life Battery life: 5 years at 25°C The RTC will be backed up for 5 days after the battery runs low. The RTC will be backed up by a super capacitor for 5 minutes after removing the old battery. (This assumes that the power is first turned ON for at least 5 minutes and then turned OFF.) International standards *5 UL 508/CSA standard C22.2 No.142 *6 EMC Directive (2004/108/EC) EN 61131-2: 2007 Shipbuilding standards LR, DNV, and NK IP65 oil-proof, UL Type 4X *7 (front panel only) ANSI 12.12.01 Class 1 Division 2/CSA standard C22.2 No. 213-M1987 (R2013) RoHS Directive (2002/95/EC) KC Standards KN 61000-6-2: 2012-06 for EMS and KN 61000-6-4: 2012-06 for EMI RCM +1 45 W max. +1 +1 40 W max. +1 35 W max. +1 *1. The ambient operating temperature is subject to the following restrictions, depending on the mounting angle. • The ambient operating temperature is 0° to 40°C when the mounting angle is 0° or more and less than 45° to the horizontal. • The ambient operating temperature is 0° to 50°C when the mounting angle is 45° or more and 90° or less to the horizontal. • The ambient operating temperature is 0° to 50°C when the mounting angle is 90° or more and 135° or less to the horizontal. +1 +0.5 +0.5 50°C 50°C 50°C 50°C 50°C 90° to 135° 45° to 90° 40°C 0° to 45° 40°C 100 90 80 70 60 50 40 30 20 10 0 -10 Operating temperaturehumidity range 0 10 20 30 40 Temperature [°C] *3. Store the Programmable Terminal within the following temperature and humidity ranges. Humidity [%] Humidity [%] *2. Use the Programmable Terminal within the following temperature and humidity ranges. 50 60 100 90 80 70 60 50 40 30 20 10 0 -20 -10 Storage temperaturehumidity range 0 10 20 30 40 50 Temperature [°C] 60 100 90 80 70 60 50 40 30 20 10 0 70 *4. When the NA-@WATW01 High-pressure Waterproof Attachment is used, the panel thickness is between 1.6 to 4.5 mm. *5. Check with your OMRON representative or refer to the following OMRON website for the latest information on the applicable standards for each model: www.ia.omron.com. *6. Use power supply Class 2 to conform to UL Standards. *7. Use the NA-@WATW01 High-pressure Waterproof Attachment (sold separately) to conform to UL Type 4X. 25 NA series Version Information NA series and Programming Devices NA series Model NA5-15W NA5-12W NA5-9W NA5-7W Corresponding unit versions/version NJ/NX-series CPU Units NX701-@@@@ NJ501-@@@@ NJ301-@@@@ NJ101-@@@@ NA system version Sysmac studio 1.02 or later NX701: 1.10 or later NJ101: 1.10 or later 1.13 or higher 1.01 or later NJ501 : 1.01 or later NJ501 Database Connection : 1.05 or later NJ301 : 1.01 or later 1.11 or higher Components and Functions Front Panel (2) RUN indicator (1) Display F1 Key F2 Key F3 Key (3) Function keys No. Description Name (1) Display (2) RUN indicator The entire display is a touch panel that also functions as an input device. The status of the indicator changes according to the status of the NA. There are three function keys: F1, F2, and F3. : F1 Key, (3) : F2 Key, : F3 Key Function keys You can use the function keys as execution conditions for the actions for global or page events. You can also use the function keys for interlocks. 26 NA series (m) ID information label Back Panel (i) Battery connector (j) DIP switch (for future expansion) (k) Battery (a) Battery cover (b) Expansion Unit connector (for future expansion) (Appearance with the Battery Cover Open) Bottm Panel (d) Ethernet ports (e) Serial port (for future expansion) 1 2 (c) SD Memory Card connector (f) USB host port (g) USB slave port (l) Power supply connector (h) Reset switch No. Description Name (a) Battery cover Open this cover to replace the Battery. (b) Expansion Unit connector * For future expansion. (c) SD Memory Card connector Insert an SD Memory Card here. Ethernet port 1 Connect a device other than the Sysmac Studio. Ethernet port 2 Connect mainly the Sysmac Studio. (e) Serial port * For future expansion. (f) USB host port Connect this port to a USB Memory Device, mouse, etc. (g) USB slave port Connect the Sysmac Studio or other devices. (d) (h) Reset switch Use this switch to reset the NA. (i) Battery connector Connect the connector on the backup Battery here. (j) DIP switch * For future expansion. (The DIP switch is on a PCB that is accessed by opening the Battery cover.) Do not change any of the factory settings of the pins on the DIP switch. (Default setting: OFF) (k) Battery This is the battery to backup the clock information in the NA. (l) DC input terminals These are the power supply terminals. Connect the accessory power supply connector and supply power. (m) ID information label You can check the ID information of the NA. * The DIP switch, Expansion Unit connector, and serial port are for future expansion. Supported Devices Manufacturer OMRON Models Connection method NX701-@@@@ NJ501-@@@@ NJ301-@@@@ NJ101-@@@@ Built-in EtherNet/IP port CJ2H-CPU64/65/66/67/68-EIP CJ2M-CPU31/32/33/34/35 Built-in EtherNet/IP port CJ2H-CPU64/65/66/67/68-EIP CJ2M-CPU31/32/33/34/35 CJ1W-EIP21 CJ2H-CPU64/65/66/67/68-EIP CJ2M-CPU31/32/33/34/35 Built-in EtherNet/IP port CJ1H-CPU65H/66H/67H CJ1H-CPU65H/66H/67H-R CJ1G-CPU42H/43H/44H/45H CJ1M-CPU11/12/13/21/22/23 CJ2H-CPU64/65/66/67/68(-EIP) CJ2M-CPU11/12/13/14/15 CJ2M-CPU31/32/33/34/35 CJ1W-ETN21 CJ1W-EIP21 Communications driver Ethernet CIP Ethernet FINS Ethernet 27 NA series Dimensions (Unit: mm) NA5-15W101S/-15W101B 194.2 391 420 139.1 291 267 6 33.5 69.1 Cable Connection Dimensions 32. 6 37 0 41.6 41.2 42 33.9 34.4 39.6 42.1 3 2.3 17 24.8 47.3 55.7 73 36 44 55 71 69.3 NA5-12W101S/-12W101B 194.2 309 340 139.1 244 220 6 33.5 69.1 Cable Connection Dimensions 10.4 10. 9 25.8 0 41.6 41.2 42 32.6 37 39.6 42.1 3 17 24.8 47.3 55.7 36 69.3 73 28 44 55 71 NA series NA5-9W001S/-9W001B 194.2 260 290 190 139.1 165 6 33.5 69.1 Cable Connection Dimensions 32. 6 37 0 41.6 41.2 42 16. 6 39.6 42.1 17. 1 3 17 24.8 53. 3 47.3 55.7 36 55 71 73 69.3 44 NA5-7W001S/-7W001B 196 236 140 165 6 69.1 Cable Connection Dimensions 29.5 29 0 41.6 41.2 42 32.6 37 39.6 42.1 66 3 17 24.8 47.3 36 69.3 55.7 73 44 55 71 29 NA series Related Manuals Cat. No. 30 Model number Manual V117 NA5-15W@@@@ NA5-12W@@@@ NA5-9W@@@@ NA5-7W@@@@ NA-series Programmable Terminal Hardware User’s Manual V118 NA5-15W@@@@ NA5-12W@@@@ NA5-9W@@@@ NA5-7W@@@@ NA-series Programmable Terminal Software User's Manual V119 NA5-15W@@@@ NA5-12W@@@@ NA5-9W@@@@ NA5-7W@@@@ NA-series Programmable Terminal Device Connection User’s Manual V120 NA5-15W@@@@ NA5-12W@@@@ NA5-9W@@@@ NA5-7W@@@@ NA-series Programmable Terminal Startup Guide Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. Note: Do not use this document to operate the Unit. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2014-2015 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_6_1_1115 Cat. No. V413-E1-04 1115 (0614)