Temperature Sensor E52 CSM_E52_DS_E_19_2 A Wide Variety of High-precision Temperature Sensors • Previous models with M3 screw connections have been joined by new models with ferrules to help reduce wiring work. • Ideal for the thermal input devices of Temperature Controllers. • Select from a wide variety of Temperature Sensors according to the temperature to be measured, location, and environment, and also according to the type and shape of the terminal. Refer to Safety Precautions for All Temperature Controllers. Ordering Information ■ List of Models (Temperature Sensors) Classification Generalpurpose Models Description Model and appearance Sheathed E52-P@AY platinum resistance E52-P@C-N thermometer E52-P@B-N −196°C to 450°C Pt100 Sheathed thermocouple 0°C to 900°C K (CA) J (IC) 3-conduc- B tor system Protective tubing material Terminal type Exposed 5 lead wires ASTM316L Enclosed terminals Nongrounded type 2 (0.75) Enclosed terminals ASTM316L Exposed 9 to lead wires 12 E52-CA@C-N E52-IC@C-N Enclosed terminals E52-CA@B-N E52-IC@B-N SUS316 E52-CA1DY E52-IC1DY 0°C to 1,400°C R (PR) 0°C to 250°C Pt100 −50°C to 250°C 0°C to 400°C K (CA) J (IC) 2 (0.25) 3-conduc- B tor system 13 14 Enclosed terminals 15 JIS ceramic Enclosed JIS special terminals ceramic 16 SUS316 Exposed 17 lead wires SUS304 Nongrounded type 2 (0.75) Grounded type E52-CA6F-N E52-IC6F-N E52-CA6D-N E52-IC6D-N E52-CA10AE-N E52-IC10AE-N 7 Exposed terminals E52-CA@C-N E52-IC@C-N E52-CA@ASY E52-IC@ASY 6 SUS316 Exposed terminals Low-cost E52-P10AEY platinum resistance E52-P6DY thermomE52-P6FY eter Page SUS316 E52-CA@B-N E52-IC@B-N E52-PR@C-N Low-cost thermocouple Class Exposed terminals 0°C to 450°C E52-CA@AY E52-IC@AY Conductor type −196°C to 450°C Standard E52-P@C-N platinum resistance thermometer Standard thermocouple Low-cost Models TemperaElement ture range type (See note 3.) 18 19 20 Nongrounded type Note: 1. Exclusive models are provided on the following page. 2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use. 3. The temperature range varies with the material, thickness, construction, and element type of the protective tubing. 1 E52 Classification Description Model and appearance Exclusive Models Bayonet spring for molding machines E52-CA2GVY E52-IC2GVY 0°C to 350°C K (CA) J (IC) Crimping terminals E52-CA1GTY E52-IC1GTY 0°C to 300°C Used for measuring surface temperatures E52-P2GSY −50°C to 250°C Conductor type Class Grounded 2 (0.75) type Pt100 3-conduc- B tor system −50°C to 60°C Double-el- E52-CA20AY-7 ement model 0°C to 900°C K (CA) Two nongrounded types E52-P20AY-7 −196°C to 250°C Two 3B conductor systems E52-P20C-N-7 −200°C to 450°C E52-P5AY-40 Corrosion- E52-P20AY-1 resistant model E52-CA20AY-1 Protective tubing material SUS304 Terminal Page type Exposed 21 lead wires --- Used for E52-P10GRY room temperature measurement WaterE52-P10GPY proof model Thermistors TemperaElement ture range type (See note 3.) SUS304 22 Pt100 2 (0.75) ASTM316L 27 Enclosed terminals 0°C to 70°C 3-conductor system SUS304 −50°C to 180°C 28 Exposed 22 lead wires Fluororesin tubing 24 SUS304 29 −80°C to 180°C 0°C to 180°C K (CA) Nongrounded type Silicone- E52-CA1DY-40 covered lead wires 0°C to 300°C Grounded type E52-CA1GTY-14 0°C to 200°C 2 (0.75) --- Explosion- E52-P@@C-N-6 proof model --- Pt100 3-conduc- B tor system E52-CA@@C-N-6 --- K (CA) Nongrounded type E52-THE5A E52-THE6F E52-THE6D −50°C to 300°C Thermistor Element- 1 interchangeable thermistor ASTM316L Enclosed terminals 25 SUS304 Exposed 31 lead wires 2 (0.75) Note: 1. General-purpose models and low-cost models are provided on the previous page. 2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use. 3. The temperature range varies with the material, thickness, construction, and element type of the protective tubing. Use the temperature sensors with ferrule from the list on the next page. 2 E52 ■ List of Models (Temperature Sensors with ferrule) Classification Generalpurpose Models Low-cost Models Exclusive Models Description Model and appearance TemperaElement ture range type (See note 3.) Sheathed E52-P@AF platinum resistance thermometer −196°C to 450°C Sheathed E52-CA@AF thermocou ple Pt100 Conductor type Class Protective tubing material Terminal Page type 3-conduc- B tor system SUS316 0°C to 900°C K (CA) Nongrounded type ASTM316L 35 to 33 Low-cost E52-P10AEF platinum resistance E52-P6DF thermometer E52-P6FF 0°C to 250°C Pt100 3-conduc- B tor system SUS316 37 Low-cost thermocouple E52-CA1DF 0°C to 400°C K (CA) Grounded 2 (0.75) type Bayonet spring for molding machines E52-CA2GVF 0°C to 350°C K (CA) Grounded 2 (0.75) type Crimping terminals E52-CA1GTF 0°C to 300°C −50°C to 250°C Used for E52-P2GSF measuring surface temperatures −50°C to 250°C Used for E52-P10GRF room temperature measurement −50°C to 60°C Waterproof E52-P10GPF model 0°C to 70°C 2 (0.75) Silicone- E52-CA1DF-40 covered lead wires Pt100 38 SUS304 39 3-conduc- B tor system SUS304 40 0°C to 300°C K (CA) E52-CA1GTF-14 SUS304 --- −50°C to 180°C E52-P5AF-40 Exposed 33 lead wires Grounded 2 (0.75) type 0°C to 200°C Fluororesin tubing 41 SUS304 42 --- Note: 1. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use. 2. The temperature range varies with the material, thickness, construction, and element type of the protective tubing. ■ Accessories It is recommended that the following accessories be used for mounting Temperature Sensors. Accessory Compression Fitting Temperature range 600°C max. Mounting example Mounting with Compression Fitting Page 43 Terminal box Compression Fitting PT screw Welding Loose Flange 400°C max. Mounting with Loose Flange Loose Flange Mounting screw Protective tubing Terminal box Protective tubing Note: The Compression Fitting is not of airtight construction. Do not use the Compression Fitting for applications in which the exposure of the sensing object will cause problems. Note: 1. Use the Loose Flange in normal atmospheric pressure. The Loose Flange is not of airtight construction. 2. Use the Loose Flange at 400°C max. 3. Do not apply the Loose Flange to protective tubing diameters other than the applicable ones. 3 E52 General-purpose Models ■ Model Number Legend The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below. Platinum Resistance Thermometers E52-@@@ D=@@@M 1 2 3 4 5 6 1. Element type P: Pt100 2. Protective tubing length (L) Specify the length in centimeters within the following range: Unit (cm) E52-@@AY Diameter (D) Length (L) 3.2 7 to 100 4.8 10 to 600 6.4 13 to 1,300 4. Diameter 3.2: 3.2-mm dia. (Protective tubing construction: Sheathed) E52-@@AY and E52-@@C-N only 4.8: 4.8-mm dia. (Protective tubing construction: Sheathed) E52-@@AY and E52-@@C-N only 6.4: 6.4-mm dia. (Protective tubing construction: Sheathed) E52-@@AY and E52-@@C-N only 8: 8-mm dia. (Protective tubing construction: Sheathed) E52-@@B-N and E52-@@C-N only 10: 10-mm dia. (Protective tubing construction: Standard) E52-@@C-N only 5. Heat resistance E52-@@B-N Code Diameter (D) 8 Length (L) Diameter (D) Vinyl-covered NETU 0°C to 180°C Sleeve: 0°C to 100°C Glass-wool-covered, externally shielded with stainless Length (L) 3.2 12 to 100 4.8 15 to 600 6.4 18 to 1,300 8 21 to 100 10 26 to 100 Lead type −20°C to 70°C Sleeve: 0°C to 70°C 20 to 100 E52-@@C-N Temperature range --- Specify for E52-@@AY model only. 6. Lead length (M) Specify the length in meters within the following range for the E52@@AY only: Range: 0.5, 1 to 100 m 3. Terminal AY: Exposed lead wires (Y-type crimp terminal for M3.5) B-N: Exposed terminals C-N: Enclosed terminals Examples Element: Pt100, protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m E52-P42AY D=4.8 NETU 10M ■ Sheathed Platinum Resistance Thermometers Refer to Model Number Legend above for the Pt100. Specifications Element type Pt100 Class JIS class B Sheath material SUS316 (E52-P@AY) ASTM316L (E52-P@B-N, E52-P@C-N) Sheath outer diameter 3.2 dia., 4.8 dia., 6.4 dia., 8 dia Conductor type 3-conductor system Temperature range −196°C to 450°C (in dry air) 4 E52 Exposed-lead Models E52-P@AY Dimensions Marking tube (Red) Shrinkable tube (Black) Sleeve (SUS304) Sheath (SUS316) Swage Marking tube (White) Unit (mm) Crimping terminal Y type for M3.5 White Product Label d l 3.2 dia. 8 40 4.8 dia. 8 40 6.4 dia. 8 40 D Red Red (A) Lead wire Lead Wire White (B) D±0.05 8 dia. Black (B) (30) L±3% 40 M±4% (80) 85±10 • Standard (−20°C to 70°C): Fully vinyl-covered with twelve 0.18-dia conductors (0.3 mm thick) and 4.8 mm in outer dia. The sleeve resists a temperature range between 0°C and 70°C. • Heat Resistive (0°C to 180°C): Fully glass-wool-covered with thirty 0.12-dia. conductors (0.3 mm thick) externally shielded with stainless steel, 4 mm in outer dia. The sleeve resists a temperature range between 0°C and 100°C. • Lead Wire Length (M): 1, 2, 4, or 8 m Model Information Custom-made models are available on request. Refer to page 4 for details. Terminal type Protective tubing diameter D (mm) Exposed-lead 3.2 dia. Models Protective tubing length L (cm) 15 20 35 4.8 dia. 20 35 50 Lead wire type 20 35 50 2 4 8 Model Standard E52-P15AY D=3.2 E52-P15AY D=3.2 E52-P15AY D=3.2 E52-P15AY D=3.2 1M 2M 4M 8M Heat resistive E52-P15AY D=3.2 E52-P15AY D=3.2 E52-P15AY D=3.2 E52-P15AY D=3.2 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P20AY D=3.2 E52-P20AY D=3.2 E52-P20AY D=3.2 E52-P20AY D=3.2 1M 2M 4M 8M Heat resistive E52-P20AY D=3.2 E52-P20AY D=3.2 E52-P20AY D=3.2 E52-P20AY D=3.2 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P35AY D=3.2 E52-P35AY D=3.2 E52-P35AY D=3.2 E52-P35AY D=3.2 1M 2M 4M 8M Heat resistive E52-P35AY D=3.2 E52-P35AY D=3.2 E52-P35AY D=3.2 E52-P35AY D=3.2 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P20AY D=4.8 E52-P20AY D=4.8 E52-P20AY D=4.8 E52-P20AY D=4.8 1M 2M 4M 8M Heat resistive E52-P20AY D=4.8 E52-P20AY D=4.8 E52-P20AY D=4.8 E52-P20AY D=4.8 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P35AY D=4.8 E52-P35AY D=4.8 E52-P35AY D=4.8 E52-P35AY D=4.8 1M 2M 4M 8M Heat resistive E52-P35AY D=4.8 E52-P35AY D=4.8 E52-P35AY D=4.8 E52-P35AY D=4.8 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P50AY D=4.8 1M E52-P50AY D=4.8 NETU 1M Heat resistive 6.4 dia. Lead wire length M (m) 1 E52-P50AY D=4.8 2M E52-P50AY D=4.8 NETU 2M E52-P50AY D=4.8 4M E52-P50AY D=4.8 NETU 4M E52-P50AY D=4.8 8M E52-P50AY D=4.8 NETU 8M Standard E52-P20AY D=6.4 E52-P20AY D=6.4 E52-P20AY D=6.4 E52-P20AY D=6.4 1M 2M 4M 8M Heat resistive E52-P20AY D=6.4 E52-P20AY D=6.4 E52-P20AY D=6.4 E52-P20AY D=6.4 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P35AY D=6.4 E52-P35AY D=6.4 E52-P35AY D=6.4 E52-P35AY D=6.4 1M 2M 4M 8M Heat resistive E52-P35AY D=6.4 E52-P35AY D=6.4 E52-P35AY D=6.4 E52-P35AY D=6.4 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P50AY D=6.4 E52-P50AY D=6.4 E52-P50AY D=6.4 E52-P50AY D=6.4 1M 2M 4M 8M Heat resistive E52-P50AY D=6.4 E52-P50AY D=6.4 E52-P50AY D=6.4 E52-P50AY D=6.4 NETU 1M NETU 2M NETU 4M NETU 8M 5 E52 Enclosed-terminal Models E52-P@C-N Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. (66) Product label Cap Socket (SUS304) Sheath (ASTM316L) Swage 58 dia. D±0.05 (66) Terminal box (15) Chain 40 G 3 8 L-35±3% Use wiring terminals that fit M3 screws. (Packing internal diameter : 6.5 dia) Terminal box: The permissible temperature is 0°C to 90°C. Note: 1. The terminals in the cap indicate polarity (A, B, b). 2. The length L is in centimeters, but “35” is 35 millimeters. Therefore, for the E52-P35C-N: L = 35 (cm), the sheath length L − 35 = 350 − 35 = 315 mm. Model Information Custom-made models are available on request. Refer to page 4 for details. Terminal type Protective tubing length L (cm) Enclosed-terminal Models Protective tubing diameter D (mm) 3.2 dia. 4.8 dia. 6.4 dia. 8 dia. Model 20 E52-P20C-N D=3.2 E52-P20C-N D=4.8 E52-P20C-N D=6.4 E52-P20C-N D=8 35 E52-P35C-N D=3.2 E52-P35C-N D=4.8 E52-P35C-N D=6.4 E52-P35C-N D=8 50 E52-P50C-N D=3.2 E52-P50C-N D=4.8 E52-P50C-N D=6.4 E52-P50C-N D=8 75 --- E52-P75C-N D=4.8 E52-P75C-N D=6.4 --- Exposed-terminal Models E52-P@B-N Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. Model Information Terminal box Socket (SUS304) 5.6 Product label Swage b B A Sheath (ASTM316L) 8±0.05 dia. Custom-made models are available on request. Refer to page 4 for details Terminal type 19.2 45 17 17.6 19 dia. 21.5 3×M3 30.5 42.5 (51) (15) L-40±3% Terminal box: The permissible temperature is 0°C to 100°C. Exposedterminal Models Protective Protective tubing diameter D (mm) tubing length 8 dia. L (cm) Model 20 E52-P20B-N D=8 35 E52-P35B-N D=8 50 E52-P50B-N D=8 Note: The length L is in centimeters, but “40” is 40 millimeters. Therefore, for the E52-P35B-N: L = 35 (cm), the sheath length L − 40 = 350 − 40 = 310 mm. 6 E52 ■ Standard Platinum Resistance Thermometers Refer to Model Number Legend on page 4 for the Pt100. Specifications Element type Pt100 Class JIS class B Protective tubing material SUS316 Conductor type 3-conductor system Temperature range 0°C to 450°C (in dry air) Note: 1. Use the sheathed platinum resistance thermometer if condensation is likely to result. Enclosed-terminal Models E52-P@C-N Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. (92) Product label Cap Socket (SUS304) Full-circled Welding 82 dia. Protective tubing (SUS316) 10±0.3 dia. (86) 38 dia. Chain G1 2 (Packing internal diameter : 9 dia.) Terminal box (5) L-50±3% 53 Note: 1. The length L is in centimeters, but “50” is 50 millimeters. Therefore, for the E52-P75C-N: L = 75 (cm), the protective tubing length L − 50 = 750 − 50 = 700 mm. Terminal box: The permissible temperature is 0°C to 90°C. Note: The terminals in the cap indicate polarity (A, B, B). Model Information Custom-made models are available on request. Refer to page 4 for details. Terminal type Protective tubing length L (cm) Protective tubing diameter D (mm) 10 dia. Model Enclosed-terminal Models 35 E52-P35C-N D=10 50 E52-P50C-N D=10 75 E52-P75C-N D=10 100 E52-P100C-N D=10 7 E52 ■ Model Number Legend The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below. Thermocouples E52-@@@ D=@@@M@ 1 2 3 4 5 6 7 1. Element type CA:K IC: J PR:R 2. Protective tubing length (L) Specify the length in centimeters in the following range: Unit (cm) 4. Diameter Specify the protective tubing material according to the table. Code Diameter Protective tubing (D) construction Protective tubing material 1 1 mm Sheathed ASTM316L 1.6 1.6 mm Sheathed ASTM316L E52-@@AY (Exposed-lead Model) 3.2 3.2 mm Sheathed ASTM316L Diameter (D) 4.8 4.8 mm Sheathed ASTM316L 6.4 6.4 mm Sheathed ASTM316L 8 8 mm Sheathed ASTM316L 10 10 mm Standard SUS316, SUS310S 12 12 mm Standard SUS316, SUS310S 15 15 mm Standard Length (L) 1 2 to 200 1.6 3 to 500 3.2 5 to 2,000 4.8 8 to 2,300 6.4 10 to 1,200 8 12 to 1,000 E52-@@B-N and E52-@@C-N (except E52-PR@C-N) Diameter (D) Length (L) 3.2 11 to 2,000 4.8 14 to 2,300 6.4 16 to 1,200 8.0 18 to 1,000 10 21 to 126 12 24 to 126 15 29 to 156 22 39 to 206 E52-PR@C-N Diameter (D) 15 SUS316, SUS310S PT1, PT0 (E52-PR) 22 22 mm Standard SUS316, SUS310S 5. Heat resistance Specify this item for the exposed-lead models only. Code Temperature range Lead type --- −20°C to 70°C Sleeve: 0°C to 70°C Vinyl-covered NETU 0°C to 150°C Sleeve: 0°C to 100°C Glass-wool-covered with external shield of stainless 6. Lead length (M) Specify the length in meters in the following range for the E52@@AY only. Range: 1 to 100 m 7. Protective tubing material Length (L) Code 50, 75, 100 3. Terminal AY: Exposed lead wires (Y-type crimp terminal for M3.5) (element type: K, J) B-N: Exposed terminals (element type: K, J) C-N: Enclosed terminals (element type: K, J, R) Protective tubing material Element type --- ASTM316L K, J SUS310S SUS310S K, D = 10 to 22 PT1 JIS ceramic Cat.1 R PT0 JIS special ceramic R Examples Element: K; protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m E52-CA42AY D=4.8 NETU 10M Element: J; protective tubing length: 360 mm, enclosed terminals, protective tubing dia.: 3.2 E52-IC36C-N D=3.2 8 E52 ■ Sheathed Thermocouples Specifications Permissible Temperature in Dry Air D Element type K (CA), J(IC) Class JIS class 2 (0.75) Thermal contact Non-grounded type Sheath material CA: ASTM316L Element wire K (CA) ASTM316L IC: ASTM316L J (IC) ASTM316L 1 dia. 650°C 450°C 1.6 dia. 650°C 450°C 3.2 dia. 750°C 650°C 4.8 dia. 800°C 750°C 6.4 dia. 800°C 750°C 8.0 dia. 900°C 750°C Note: For details on the permissible temperature, refer to page D-5 of Introduction of Temperature Controllers (Cat. No. H900). Exposed-lead Models E52-CA@AY Dimensions Sleeve (SUS304) Sheath (ASTM316L) Swage Lead wire Unit (mm) Crimping terminal Y type for M3.5 Shrinkable tube (CA:Blue, IC:Yellow) Red (+) Product label D±0.05 30±5 M±4% 55 l 8 55 1.6 dia. 8 55 3.2 dia. 8 55 4.8 dia. 8 55 6.4 dia. 11 55 8 dia. 11 55 D d L±3% d 1 dia. Transparent Marking tube (White) (80) 90±10 White (−) Note: 1. Lead Wire (Compensating Conductor) • Standard (−20°C to 70°C): Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) and external dimensions of 2.4 × 4.1. • Heat Resistive (0°C to 150°C): Fully glass-wool-covered with seven 0.3-dia. conductors (0.5 mm thick) with external shield of stainless steel and external dimensions of 2.8 × 4.6 The heat-resistive lead wires cannot be used in locations exposed to water or other liquids. • Lead Wire Length (M): 1, 2, 4, or 8 m 2. The sleeve resists temperatures ranging between −20°C and 70°C for standard models and 0°C and 100°C for heat-resistive models. Permissible Temperature in Dry Air D Element wire K (CA) ASTM316L 1 dia. 650°C 1.6 dia. 650°C 3.2 dia. 750°C 4.8 dia. 800°C 6.4 dia. 800°C 8.0 dia. 900°C K (CA) Model Information (E52-CA@AY) Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details. Terminal type Protective Protective tubing diameter tubing length L D (mm) (cm) Lead wire type Lead wire length M (m) 1 2 4 8 Model Exposed-lead Models 1 dia. 15 20 35 Standard E52-CA15AY D=1 1M E52-CA15AY D=1 2M E52-CA15AY D=1 4M E52-CA15AY D=1 8M Heat resistive E52-CA15AY D=1 NETU 1M E52-CA15AY D=1 NETU 2M E52-CA15AY D=1 NETU 4M E52-CA15AY D=1 NETU 8M Standard E52-CA20AY D=1 1M E52-CA20AY D=1 2M E52-CA20AY D=1 4M E52-CA20AY D=1 8M Heat resistive E52-CA20AY D=1 NETU 1M E52-CA20AY D=1 NETU 2M E52-CA20AY D=1 NETU 4M E52-CA20AY D=1 NETU 8M Standard E52-CA35AY D=1 1M E52-CA35AY D=1 2M E52-CA35AY D=1 4M E52-CA35AY D=1 8M Heat resistive E52-CA35AY D=1 NETU 1M E52-CA35AY D=1 NETU 2M E52-CA35AY D=1 NETU 4M E52-CA35AY D=1 NETU 8M 9 E52 Terminal type Protective Protective tubing diameter tubing length L D (mm) (cm) Lead wire type Lead wire length M (m) 1 2 4 8 Model Exposed-lead Models 1.6 dia. 15 20 35 3.2 dia. 15 20 35 50 4.8 dia. 20 35 50 6.4 dia. 20 35 50 8 dia. 20 35 50 Standard E52-CA15AY D=1.6 1M E52-CA15AY D=1.6 2M E52-CA15AY D=1.6 4M E52-CA15AY D=1.6 8M Heat resistive E52-CA15AY D=1.6 NETU 1M E52-CA15AY D=1.6 NETU 2M E52-CA15AY D=1.6 NETU 4M E52-CA15AY D=1.6 NETU 8M Standard E52-CA20AY D=1.6 1M E52-CA20AY D=1.6 2M E52-CA20AY D=1.6 4M E52-CA20AY D=1.6 8M Heat resistive E52-CA20AY D=1.6 NETU 1M E52-CA20AY D=1.6 NETU 2M E52-CA20AY D=1.6 NETU 4M E52-CA20AY D=1.6 NETU 8M Standard E52-CA35AY D=1.6 1M E52-CA35AY D=1.6 2M E52-CA35AY D=1.6 4M E52-CA35AY D=1.6 8M Heat resistive E52-CA35AY D=1.6 NETU 1M E52-CA35AY D=1.6 NETU 2M E52-CA35AY D=1.6 NETU 4M E52-CA35AY D=1.6 NETU 8M Standard E52-CA15AY D=3.2 1M E52-CA15AY D=3.2 2M E52-CA15AY D=3.2 4M E52-CA15AY D=3.2 8M Heat resistive E52-CA15AY D=3.2 NETU 1M E52-CA15AY D=3.2 NETU 2M E52-CA15AY D=3.2 NETU 4M E52-CA15AY D=3.2 NETU 8M Standard E52-CA20AY D=3.2 1M E52-CA20AY D=3.2 2M E52-CA20AY D=3.2 4M E52-CA20AY D=3.2 8M Heat resistive E52-CA20AY D=3.2 NETU 1M E52-CA20AY D=3.2 NETU 2M E52-CA20AY D=3.2 NETU 4M E52-CA20AY D=3.2 NETU 8M Standard E52-CA35AY D=3.2 1M E52-CA35AY D=3.2 2M E52-CA35AY D=3.2 4M E52-CA35AY D=3.2 8M Heat resistive E52-CA35AY D=3.2 NETU 1M E52-CA35AY D=3.2 NETU 2M E52-CA35AY D=3.2 NETU 4M E52-CA35AY D=3.2 NETU 8M Standard E52-CA50AY D=3.2 1M E52-CA50AY D=3.2 2M E52-CA50AY D=3.2 4M E52-CA50AY D=3.2 8M Heat resistive E52-CA50AY D=3.2 NETU 1M E52-CA50AY D=3.2 NETU 2M E52-CA50AY D=3.2 NETU 4M E52-CA50AY D=3.2 NETU 8M Standard E52-CA20AY D=4.8 1M E52-CA20AY D=4.8 2M E52-CA20AY D=4.8 4M E52-CA20AY D=4.8 8M Heat resistive E52-CA20AY D=4.8 NETU 1M E52-CA20AY D=4.8 NETU 2M E52-CA20AY D=4.8 NETU 4M E52-CA20AY D=4.8 NETU 8M Standard E52-CA35AY D=4.8 1M E52-CA35AY D=4.8 2M E52-CA35AY D=4.8 4M E52-CA35AY D=4.8 8M Heat resistive E52-CA35AY D=4.8 NETU 1M E52-CA35AY D=4.8 NETU 2M E52-CA35AY D=4.8 NETU 4M E52-CA35AY D=4.8 NETU 8M Standard E52-CA50AY D=4.8 1M E52-CA50AY D=4.8 2M E52-CA50AY D=4.8 4M E52-CA50AY D=4.8 8M Heat resistive E52-CA50AY D=4.8 NETU 1M E52-CA50AY D=4.8 NETU 2M E52-CA50AY D=4.8 NETU 4M E52-CA50AY D=4.8 NETU 8M Standard E52-CA20AY D=6.4 1M E52-CA20AY D=6.4 2M E52-CA20AY D=6.4 4M E52-CA20AY D=6.4 8M Heat resistive E52-CA20AY D=6.4 NETU 1M E52-CA20AY D=6.4 NETU 2M E52-CA20AY D=6.4 NETU 4M E52-CA20AY D=6.4 NETU 8M Standard E52-CA35AY D=6.4 1M E52-CA35AY D=6.4 2M E52-CA35AY D=6.4 4M E52-CA35AY D=6.4 8M Heat resistive E52-CA35AY D=6.4 NETU 1M E52-CA35AY D=6.4 NETU 2M E52-CA35AY D=6.4 NETU 4M E52-CA35AY D=6.4 NETU 8M Standard E52-CA50AY D=6.4 1M E52-CA50AY D=6.4 2M E52-CA50AY D=6.4 4M E52-CA50AY D=6.4 8M Heat resistive E52-CA50AY D=6.4 NETU 1M E52-CA50AY D=6.4 NETU 2M E52-CA50AY D=6.4 NETU 4M E52-CA50AY D=6.4 NETU 8M Standard E52-CA20AY D=8 1M E52-CA20AY D=8 2M E52-CA20AY D=8 4M E52-CA20AY D=8 8M Heat resistive E52-CA20AY D=8 NETU 1M E52-CA20AY D=8 NETU 2M E52-CA20AY D=8 NETU 4M E52-CA20AY D=8 NETU 8M Standard E52-CA35AY D=8 1M E52-CA35AY D=8 2M E52-CA35AY D=8 4M E52-CA35AY D=8 8M Heat resistive E52-CA35AY D=8 NETU 1M E52-CA35AY D=8 NETU 2M E52-CA35AY D=8 NETU 4M E52-CA35AY D=8 NETU 8M Standard E52-CA50AY D=8 1M E52-CA50AY D=8 2M E52-CA50AY D=8 4M E52-CA50AY D=8 8M Heat resistive E52-CA50AY D=8 NETU 1M E52-CA50AY D=8 NETU 2M E52-CA50AY D=8 NETU 4M E52-CA50AY D=8 NETU 8M 10 E52 Exposed-lead Models E52-IC@AY Dimensions Sleeve (SUS304) Sheath (ASTM316L) Product label Swage Red (+) d 30±5 L±3% 55 M±4% Unit (mm) (80) 90±10 White (−) Note: 1. Lead Wire (Compensating Conductor) • Standard (−20°C to 70°C): Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) and external dimensions of 2.4 × 4.1. • Heat Resistive (0°C to 150°C): Fully glass-wool-covered with seven 0.3-dia. conductors (0.5 mm thick) with external shield of stainless steel and external dimensions of 2.8 × 4.6 The heat-resistive lead wires cannot be used in locations exposed to water or other liquids. • Lead Wire Length (M): 1, 2, 4, or 8 m 2. The sleeve resists temperatures ranging between −20°C and 70°C for standard models and 0°C and 100°C for heat-resistive models. Permissible Temperature in Dry Air d l 1 dia. 8 55 1.6 dia. 8 55 3.2 dia. 8 55 4.8 dia. 8 55 6.4 dia. 11 55 8 dia. 11 55 D Transparent Marking tube (White) Lead wire D±0.05 Crimping terminal Y type for M3.5 Shrinkable tube (CA:Blue, IC:Yellow) D Element wire J (IC) ASTM316L 1 dia. 450°C 1.6 dia. 450°C 3.2 dia. 650°C 4.8 dia. 750°C 6.4 dia. 750°C 8.0 dia. 750°C J (IC) Model Information (E52-IC@AY) Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details Terminal type Protective tubing diameter D (mm) Exposed-lead 1 dia. Models Protective tubing length L (cm) 15 20 35 1.6 dia. 15 20 35 Lead wire type Lead wire length M (m) 1 2 4 Model Standard E52-IC15AY D=1 1M E52-IC15AY D=1 2M E52-IC15AY D=1 4M Heat resistive E52-IC15AY D=1 NETU 1M E52-IC15AY D=1 NETU 2M E52-IC15AY D=1 NETU 4M Standard E52-IC20AY D=1 1M E52-IC20AY D=1 2M E52-IC20AY D=1 4M Heat resistive E52-IC20AY D=1 NETU 1M E52-IC20AY D=1 NETU 2M E52-IC20AY D=1 NETU 4M Standard E52-IC35AY D=1 1M E52-IC35AY D=1 2M E52-IC35AY D=1 4M Heat resistive E52-IC35AY D=1 NETU 1M E52-IC35AY D=1 NETU 2M E52-IC35AY D=1 NETU 4M Standard E52-IC15AY D=1.6 1M E52-IC15AY D=1.6 2M E52-IC15AY D=1.6 4M Heat resistive E52-IC15AY D=1.6 NETU 1M E52-IC15AY D=1.6 NETU 2M E52-IC15AY D=1.6 NETU 4M Standard E52-IC20AY D=1.6 1M E52-IC20AY D=1.6 2M E52-IC20AY D=1.6 4M Heat resistive E52-IC20AY D=1.6 NETU 1M E52-IC20AY D=1.6 NETU 2M E52-IC20AY D=1.6 NETU 4M Standard E52-IC35AY D=1.6 1M E52-IC35AY D=1.6 2M E52-IC35AY D=1.6 4M Heat resistive E52-IC35AY D=1.6 NETU 1M E52-IC35AY D=1.6 NETU 2M E52-IC35AY D=1.6 NETU 4M 11 E52 Terminal type Protective tubing diameter D (mm) Exposed-lead 3.2 dia. Models Protective tubing length L (cm) 15 20 35 50 4.8 dia. 20 35 50 6.4 dia. 20 35 50 8 dia. 20 35 50 Lead wire type 1 Lead wire length M (m) 2 4 Model Standard E52-IC15AY D=3.2 1M E52-IC15AY D=3.2 2M E52-IC15AY D=3.2 4M Heat resistive E52-IC15AY D=3.2 NETU 1M E52-IC15AY D=3.2 NETU 2M E52-IC15AY D=3.2 NETU 4M Standard E52-IC20AY D=3.2 1M E52-IC20AY D=3.2 2M E52-IC20AY D=3.2 4M Heat resistive E52-IC20AY D=3.2 NETU 1M E52-IC20AY D=3.2 NETU 2M E52-IC20AY D=3.2 NETU 4M Standard E52-IC35AY D=3.2 1M E52-IC35AY D=3.2 2M E52-IC35AY D=3.2 4M Heat resistive E52-IC35AY D=3.2 NETU 1M E52-IC35AY D=3.2 NETU 2M E52-IC35AY D=3.2 NETU 4M Standard E52-IC50AY D=3.2 1M E52-IC50AY D=3.2 2M E52-IC50AY D=3.2 4M Heat resistive E52-IC50AY D=3.2 NETU 1M E52-IC50AY D=3.2 NETU 2M E52-IC50AY D=3.2 NETU 4M Standard E52-IC20AY D=4.8 1M E52-IC20AY D=4.8 2M E52-IC20AY D=4.8 4M Heat resistive E52-IC20AY D=4.8 NETU 1M E52-IC20AY D=4.8 NETU 2M E52-IC20AY D=4.8 NETU 4M Standard E52-IC35AY D=4.8 1M E52-IC35AY D=4.8 2M E52-IC35AY D=4.8 4M Heat resistive E52-IC35AY D=4.8 NETU 1M E52-IC35AY D=4.8 NETU 2M E52-IC35AY D=4.8 NETU 4M Standard E52-IC50AY D=4.8 1M E52-IC50AY D=4.8 2M E52-IC50AY D=4.8 4M Heat resistive E52-IC50AY D=4.8 NETU 1M E52-IC50AY D=4.8 NETU 2M E52-IC50AY D=4.8 NETU 4M Standard E52-IC20AY D=6.4 1M E52-IC20AY D=6.4 2M E52-IC20AY D=6.4 4M Heat resistive E52-IC20AY D=6.4 NETU 1M E52-IC20AY D=6.4 NETU 2M E52-IC20AY D=6.4 NETU 4M Standard E52-IC35AY D=6.4 1M E52-IC35AY D=6.4 2M E52-IC35AY D=6.4 4M Heat resistive E52-IC35AY D=6.4 NETU 1M E52-IC35AY D=6.4 NETU 2M E52-IC35AY D=6.4 NETU 4M Standard E52-IC50AY D=6.4 1M E52-IC50AY D=6.4 2M E52-IC50AY D=6.4 4M Heat resistive E52-IC50AY D=6.4 NETU 1M E52-IC50AY D=6.4 NETU 2M E52-IC50AY D=6.4 NETU 4M Standard E52-IC20AY D=8 1M E52-IC20AY D=8 2M E52-IC20AY D=8 4M Heat resistive E52-IC20AY D=8 NETU 1M E52-IC20AY D=8 NETU 2M E52-IC20AY D=8 NETU 4M Standard E52-IC35AY D=8 1M E52-IC35AY D=8 2M E52-IC35AY D=8 4M Heat resistive E52-IC35AY D=8 NETU 1M E52-IC35AY D=8 NETU 2M E52-IC35AY D=8 NETU 4M Standard E52-IC50AY D=8 1M E52-IC50AY D=8 2M E52-IC50AY D=8 4M Heat resistive E52-IC50AY D=8 NETU 1M E52-IC50AY D=8 NETU 2M E52-IC50AY D=8 NETU 4M 12 E52 Exposed-terminal Models E52-CA@B-N E52-IC@B-N Dimensions Permissible Temperature in Dry Air Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. D Element wire K (CA) ASTM316L Product label Terminal box 2×10 dia. Socket (SUS304) Swage + Sheath (ASTM316L) D±0.05 44 18 − 4 2×M3 16 8 3.2 dia. 750°C 650°C 4.8 dia. 800°C 750°C 6.4 dia. 800°C 750°C 8.0 dia. 900°C 750°C Terminal box: The permissible temperature is 0°C to 100°C. 3.5 (15) 38.5 (52) 22 dia. J (IC) ASTM316L L-40±3% Note: The length L is in centimeters, but “40” is 40 millimeters. Therefore, for the E52-CA50B-N: L = 50 (cm), the sheath length L − 40 = 500 − 40 = 460 mm. Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details. Element type Terminal type K (CA) Exposed-terminal Models J (IC) Exposed-terminal Models Protective tubing length L (cm) Protective tubing diameter D (mm) 3.2 dia. 4.8 dia. 6.4 dia. 8 dia. Model 20 E52-CA20B-N D=3.2 E52-CA20B-N D=4.8 E52-CA20B-N D=6.4 --- 35 E52-CA35B-N D=3.2 E52-CA35B-N D=4.8 E52-CA35B-N D=6.4 E52-CA35B-N D=8 50 E52-CA50B-N D=3.2 E52-CA50B-N D=4.8 E52-CA50B-N D=6.4 E52-CA50B-N D=8 75 --- E52-CA75B-N D=4.8 E52-CA75B-N D=6.4 E52-CA75B-N D=8 20 E52-IC20B-N D=3.2 E52-IC20B-N D=4.8 E52-IC20B-N D=6.4 --- 35 E52-IC35B-N D=3.2 E52-IC35B-N D=4.8 E52-IC35B-N D=6.4 E52-IC35B-N D=8 50 E52-IC50B-N D=3.2 E52-IC50B-N D=4.8 E52-IC50B-N D=6.4 E52-IC50B-N D=8 75 --- E52-IC75B-N D=4.8 E52-IC75B-N D=6.4 E52-IC75B-N D=8 Enclosed-terminal Models E52-CA@C-N E52-IC@C-N Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. (66) Permissible Temperature in Dry Air D Element wire Product label K (CA) ASTM316L Cap Socket (SUS304) Swage 58 dia. Sheath (ASTM316L) D±0.05 (66) (15) Chain Terminal box 3.2 dia. 750°C 650°C 4.8 dia. 800°C 750°C 6.4 dia. 800°C 750°C 8.0 dia. 900°C 750°C Terminal box: The permissible temperature is 0°C to 90°C. L-40±3% 40 G3 8 (Packing internal diameter 6.5 dia.) J (IC) ASTM316L Use wiring terminals that fit M3 screws. Note: The terminals in the cap indicate polarity (+ or −). Note: The length L is in centimeters, but “40” is 40 millimeters. Therefore, for the E52-CA35C-N: L = 35 (cm), the sheath length L − 40 = 350 − 40 = 310 mm. Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details. Element type Terminal type K (CA) J (IC) Enclosed-terminal Models Enclosed-terminal Models Protective tubing length L (cm) Protective tubing diameter D (mm) 3.2 dia. 4.8 dia. 6.4 dia. 8 dia. Model 20 E52-CA20C-N D=3.2 E52-CA20C-N D=4.8 E52-CA20C-N D=6.4 --- 35 E52-CA35C-N D=3.2 E52-CA35C-N D=4.8 E52-CA35C-N D=6.4 E52-CA35C-N D=8 50 E52-CA50C-N D=3.2 E52-CA50C-N D=4.8 E52-CA50C-N D=6.4 E52-CA50C-N D=8 75 --- E52-CA75C-N D=4.8 E52-CA75C-N D=6.4 E52-CA75C-N D=8 20 E52-IC20C-N D=3.2 E52-IC20C-N D=4.8 E52-IC20C-N D=6.4 --- 35 E52-IC35C-N D=3.2 E52-IC35C-N D=4.8 E52-IC35C-N D=6.4 E52-IC35C-N D=8 50 E52-IC50C-N D=3.2 E52-IC50C-N D=4.8 E52-IC50C-N D=6.4 E52-IC50C-N D=8 75 --- E52-IC75C-N D=4.8 E52-IC75C-N D=6.4 E52-IC75C-N D=8 13 E52 ■ Standard Thermocouples Specifications Permissible Temperature in Dry Air (See note.) D Element wire K (CA), J(IC), R(PR) Class K (CA), J (IC) JIS class 2 (0.75) Protective tubing material J (IC) SUS316 R(PR), JIS class 2 (0.25) 10 dia. 750°C 450°C K (CA) SUS316 12 dia. 850°C 500°C J (IC) 15 dia. 900°C 550°C 22 dia. 900°C 600°C SUS316 R (See JIS ceramic cat. 1 (PT1) note.) JIS special ceramic (PT0) Thermal contact Element wire K (CA) SUS316 Note: For details on the permissible temperature, refer to Technical Guide for Temperature Sensors. Non-grounded type Note: Specify PT1 or PT0 if the element is R. D Element wire R 15 dia. 0°C to 1,400°C Exposed-terminal Models E52-CA@B-N E52-IC@B-N Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. 25.5 9.6 25 Product label Terminal box 2×12 dia. Socket (SUS304) 18 Protective tubing (SUS316 or SUS310S) − 70 30.8 + 3.8 18 D Full-circled welding 2×M4 30 dia. 34.5 5 8 (5) 8 49.5 L-50±3% (65.5) Terminal box: The permissible temperature is 0°C to 100°C. Note: The length L is in centimeters, but “50” is 50 millimeters. Therefore, for the E52-CA75B-N: L = 75 (cm), the protective tubing length L − 50 = 750 − 50 = 700 mm. Permissible Temperature in Dry Air D Element wire K (CA) SUS316 J (IC) SUS316 10 dia. 750°C 450°C 12 dia. 850°C 500°C 15 dia. 850°C 550°C 22 dia. 900°C 600°C Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details. Element type Terminal type K (CA) J (IC) Exposed-terminal Models Exposed-terminal Models Protective tubing length L (cm) Protective tubing diameter D (mm) 10 dia. 12 dia. 15 dia. 22 dia. Model 35 E52-CA35B-N D=10 E52-CA35B-N D=12 E52-CA35B-N D=15 --- 50 E52-CA50B-N D=10 E52-CA50B-N D=12 E52-CA50B-N D=15 E52-CA50B-N D=22 75 E52-CA75B-N D=10 E52-CA75B-N D=12 E52-CA75B-N D=15 E52-CA75B-N D=22 100 E52-CA100B-N D=10 E52-CA100B-N D=12 E52-CA100B-N D=15 E52-CA100B-N D=22 35 E52-IC35B-N D=10 E52-IC35B-N D=12 E52-IC35B-N D=15 --- 50 E52-IC50B-N D=10 E52-IC50B-N D=12 E52-IC50B-N D=15 E52-IC50B-N D=22 75 E52-IC75B-N D=10 E52-IC75B-N D=12 E52-IC75B-N D=15 E52-IC75B-N D=22 100 E52-IC100B-N D=10 E52-IC100B-N D=12 E52-IC100B-N D=15 E52-IC100B-N D=22 14 E52 Enclosed-terminal Models E52-CA@C-N E52-IC@C-N Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. (92) Cap Product label 82 dia. Socket (SUS304) Full-circled Welding Protective tubing (SUS316 or SUS310S) D (86) 38 dia. Terminal box (5) Chain G1 2 L-50±3% 53 (Packing internal diameter : 9 dia.) Note: The length L is in centimeters, but “50” is 50 millimeters. Therefore, for the E52-CA50C-N: L = 50 (cm), the protective tubing length L − 50 = 500 − 50 = 450 mm. Permissible Temperature in Dry Air D Element wire K (CA) SUS316 J (IC) SUS316 10 dia. 0 to 750°C 0 to 450°C 12 dia. 0 to 850°C 0 to 500°C 15 dia. 0 to 850°C 0 to 550°C 22 dia. 0 to 900°C 0 to 600°C Terminal box: The permissible temperature is 0°C to 90°C. Note: The terminals in the cap indicate polarity (+ or −). Model Information Custom-made models are available on request. Refer to Model Number Legend on page 8 for details Element type Terminal type K (CA) J (IC) Enclosed-terminal Models Enclosed-terminal Models Protective tubing length L (cm) Protective tubing diameter D (mm) 10 dia. 12 dia. 15 dia. 22 dia. Model 35 E52-CA35C-N D=10 E52-CA35C-N D=12 E52-CA35C-N D=15 --- 50 E52-CA50C-N D=10 E52-CA50C-N D=12 E52-CA50C-N D=15 E52-CA50C-N D=22 75 E52-CA75C-N D=10 E52-CA75C-N D=12 E52-CA75C-N D=15 E52-CA75C-N D=22 100 E52-CA100C-N D=10 E52-CA100C-N D=12 E52-CA100C-N D=15 E52-CA100C-N D=22 35 E52-IC35C-N D=10 E52-IC35C-N D=12 E52-IC35C-N D=15 50 E52-IC50C-N D=10 E52-IC50C-N D=12 E52-IC50C-N D=15 E52-IC50C-N D=22 75 E52-IC75C-N D=10 E52-IC75C-N D=12 E52-IC75C-N D=15 --- 100 E52-IC100C-N D=10 E52-IC100C-N D=12 E52-IC100C-N D=15 --- --- 15 E52 Enclosed-terminal Models (High-temperature Use) E52-PR@C-N Dimensions Dimensions are given in millimeters, except for the length (L), which is provided in centimeters. (92) Cap Product label Support (SUS304) 82 dia. Ceramic protective tubing (PT0 or PT1) 15±0.7 dia. (86) * 21.7 dia. 38 dia. Chain * Tubing distortion A dimensions more than 500mm: 0.6% or less A dimensions are less than 500mm: 3mm or less Terminal box (5) G1 2 (100) (Packing internal diameter : 9 dia.) L-150±3% A 53 Use wiring terminals that fit M4 screws. Permissible Temperature in Dry Air D Element wire R 15 dia. 0°C to 1,400°C Terminal box: The permissible temperature is 0°C to 90°C. Note: The terminals in the cap indicate polarity (+ or −). Note: The length L is in centimeters, but “150” is 150 millimeters. Therefore, for the E52-PR75C-N: L = 75 (cm), the protective tubing length L − 150 = 750 − 150 = 600 mm. Model Information Element type R (See note 1.) Terminal type Protective tubing length L (cm) Enclosed-ter- 50 minal Models 75 100 R (See note 2.) Enclosed-ter- 50 minal Models 75 100 Standard Protective tubing diameter D (mm) 15 dia. Model E52-PR50C-N D=15 PT1 E52-PR75C-N D=15 PT1 E52-PR100C-N D=15 PT1 E52-PR50C-N D=15 PT0 E52-PR75C-N D=15 PT0 E52-PR100C-N D=15 PT0 Protective tubing material Permissible temperature in dry air Note 1: JIS ceramic Cat.1 (PT1) Mullite, high alumina, etc. 1,500°C (See note.) Note 2: JIS special ceramic (PT0) Recrystallized alumina, fused alumina, etc. 1,600°C (See note.) Note: The permissible temperature given for the protective tubing is higher than 1,400°C, but the permissible temperature of the thermocouple element wire is only 1,400°C. Therefore, the protective tubing of the E52-PR@C-N can withstand high temperatures momentarily to the levels given in the table as exceptions, but the element wire will deteriorate quickly if the thermocouple is used regularly at temperatures that exceed the permissible temperature for the element wire. 16 E52 Low-cost Models ■ Low-cost Platinum Resistance Thermometers Exposed-lead Models with Screws Specifications E52-P6DY Element type Pt100 Dimensions Conductor type 3-conductor system Class Class B Protective tubing material SUS304 Sensor length 30 mm Max. detectable temperature 250°C Temperature range −50°C to 250°C Lead wire Fluororesin-covered wire (PFA) with 1.0 outer dia. 7/0.18 −50°C to 150°C Taper screw for tube R1/8 (SUS304) Full-circled welding (16) Crimping terminal Y type for M3.5 Siliconized shrinkable tube Protective tubing (SUS304) Red Marking tube (Red) Red (A) Lead wire Black (B) 4±0.4 dia. White (B) Product label 6±0.5 10±0.5 Marking tube (White) White (M-16) (30) 14 65 15 0 -2 M±5% Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Model 1 E52-P6DY 1M 2 E52-P6DY 2M 4 E52-P6DY 4M Exposed-lead Models with Flange Specifications E52-P6FY Element wire Pt100 Dimensions Conductor type 3-conductor system Class Class B Protective tubing material SUS304 Sensor length 30 mm Max. detectable temperature 250°C Temperature range −50°C to 250°C Lead wire Fluororesin-covered wire (PFA) with 1.0 outer dia. 7/0.18 −50°C to 150°C Crimping terminal Y type for M3.5 Nickel brazing 3×3.5 dia. 120° Red Siliconized shrinkable tube Marking tube (Red) Lead wire Flange (SUS304) 120° 4±0.4 dia. Protective tubing (SUS304) Red (A) Black (B) White (B) Product label Marking tube (White) 1 20 dia. 65 30 dia. 15 0 -2 White (M-16) M±5% (30) Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Model 1 E52-P6FY 1M 2 E52-P6FY 2M 4 E52-P6FY 4M Exposed-lead Models Specifications E52-P10AEY Element type Pt100 Dimensions Conductor type 3-conductor system Class Class B Crimping terminal Y type for M3.5 Product label Transparent Marking tube (White) Siliconized shrinkable tube Shrinkable tube (Black) Red (A) Protective tubing material SUS316 Max. detectable temperature 250°C White (B) Temperature range 0°C to 250°C White (B) Lead wire Fluororesin-covered wire (PFA) with 1.0 outer dia. 7/0.18 −50°C to 150°C 3.2±0.05 dia. Protective tubing (SUS316) Lead wire 30 30±5 80±10 M±4% 100±3% Note: 1. The protective tubing is of pipe construction, which must not be bent. 2. A Compression Fitting (PT@) cannot be used for mounting. Lead wire length (m) Model 1 E52-P10AEY 1M 2 E52-P10AEY 2M 4 E52-P10AEY 4M 17 E52 ■ Low-cost Thermocouples Exposed-lead Models with Spring E52-CA@ASY, E52-IC@ASY Specifications Dimensions Element type K (CA), J (IC) Element dia. 0.65 mm (single wire) Class Class 2 (0.75) Protective tubing (SUS304) Protective tubing material SUS304 Thermal contact Non-grounded type Temperature range 0°C to 400°C: K (CA) 0°C to 350°C: J (IC) Lead wire 100° +0.02 4.8 0 dia. +0.2 14.5 -0.1 dia. Sleeve (Brass nickel chrome plating) 12±0.05 dia. Shrinkable tube (CA:Blue, IC:Yellow) Protective spring (SUS304) Lead wire 11±0.2 dia. 8.2±0.1 dia. Crimping terminal Y type for M3.5 Marking tube (White) Red (+) + − 5±0.5 6.3±1 18±1 L±3 Fully glass-wool-covered compensating cable and external dimensions of approx. 5.1 x 3.0 4/0.65 0°C to 180°C 1.2±0.02 dia. White (−) (20) (70) 150±1 32±2 80±10 M±1% L: Protective tubing length M: Lead wire length Note: The sleeve resists temperatures ranging between 0°C and 100°C. Note: The protective tubing is of pipe construction, which must not be bent. Protective tubing length (mm) Lead wire length (m) Element type: K (CA) Element type: J (IC) Model 65 100 150 200 1 E52-CA6ASY 1M E52-IC6ASY 1M 2 E52-CA6ASY 2M E52-IC6ASY 2M 4 E52-CA6ASY 4M E52-IC6ASY 4M 1 E52-CA10ASY 1M E52-IC10ASY 1M 2 E52-CA10ASY 2M E52-IC10ASY 2M 4 E52-CA10ASY 4M E52-IC10ASY 4M 1 E52-CA15ASY 1M E52-IC15ASY 1M 2 E52-CA15ASY 2M E52-IC15ASY 2M 4 E52-CA15ASY 4M E52-IC15ASY 4M 1 E52-CA20ASY 1M E52-IC20ASY 1M 2 E52-CA20ASY 2M E52-IC20ASY 2M 4 E52-CA20ASY 4M E52-IC20ASY 4M 18 E52 Exposed-lead Models with Screw E52-CA1DY, E52-IC1DY Specifications Dimensions Element type K (CA), J (IC) Element dia. 0.65 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 Thermal contact Grounded type Temperature range 0°C to 400°C: K (CA) 0°C to 350°C: J (IC) Sleeve (Brass nickel plated) Movable ring (Brass) End ring (Brass) Shrinkable tube (CA:Blue, IC:Yellow) Screw (SUS304) Protective copper wire 3.8±0.1 dia. Lead wire Fully glass-wool-covered with external copper shield and external dimensions of approx. 3.1 x 2.0 1/0.65 0°C to 180°C Terminal shape Y-type crimp terminal for M3.5 Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. Specify the type of screw (i.e., M6, M8, or W1/4) when ordering. 3. The thermocouple is not of airtight construction. 4. OMRON recommends that the tip of the thermocouple is touching the sensing object. Lead wire Crimping terminal Y type for M3.5 Marking tube (White) Red Red (+) PVC less tube B Blue 120° 9±1 5±0.05 dia. 3.8±1 2.8 +0.3 0 1±0.1 Black (−) (20) 0 10 -0.5 A±0.3 M±1% C Internal Construction (E52-CA1DY) 0.65-dia. black wire Movable ring Brass Cut after silver soldering (70) 80±10 Closely wound enamel-bonded coil. M6 Lead wire length (m) Screw W1/4 M6 M8 (P=1.27) (P=1.0) (P=1.25) A (mm) 4.3 4 5.3 B (mm) 11.5 11.5 15 C (mm) 10 10 13 Brass pipe Screw Shielded glass-wool lead wire Installation Example Cut a thread into the workpiece, and screw in the thermocouple while pushing in so that the tip makes complete contact. End Workpiece Note: E52-CA1DY with the same shape and multiple element wires are also available (E52-CA1DY-40). Refer to page 29 for details. Protective tubing length (mm) Lead wire length (m) Element type: K (CA) Element type: J (IC) Model M6 screw M8 screw W1/4 screw 1 E52-CA1DY M6 1M E52-IC1DY M6 1M 2 E52-CA1DY M6 2M E52-IC1DY M6 2M 4 E52-CA1DY M6 4M E52-IC1DY M6 4M 1 E52-CA1DY M8 1M E52-IC1DY M8 1M 2 E52-CA1DY M8 2M E52-IC1DY M8 2M 4 E52-CA1DY M8 4M E52-IC1DY M8 4M 1 E52-CA1DY W1/4 1M E52-IC1DY W1/4 1M 2 E52-CA1DY W1/4 2M E52-IC1DY W1/4 2M 4 E52-CA1DY W1/4 4M E52-IC1DY W1/4 4M 19 E52 Exposed-lead Models with Flange Specifications E52-CA6F-N, E52-IC6F-N Element type K (CA), J (IC) Dimensions Class Class 2 (0.75) Protective tubing material SUS304 Thermal contact Grounded type Temperature range 0°C to 350°C: K (CA) 0°C to 350°C: J (IC) Lead wire Fluororesin-covered thermocouple wire (PFA) with external dimensions of 1.6 x 1.0 1/0.32 0°C to 150°C Silver brazing Siliconized shrinkable tube 3×3.5 dia. 120° 120° Shrinkable tube (CA:Blue, IC:Yellow) Flange (SUS304) Product label Lead wire Protective tubing (SUS304) Peel treatment Red (+) White (−) (10) 4±0.05 dia. 1 (75) 80±10 (30) 20 dia. 30 dia. 15 65±2 (30) (M-16) M±5% Lead wire length (M): 1, 2, or 4 m Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Element type: K (CA) Element type: J (IC) Model 1 E52-CA6F-N 1M E52-IC6F-N 1M 2 E52-CA6F-N 2M E52-IC6F-N 2M 4 E52-CA6F-N 4M E52-IC6F-N 4M Exposed-lead Models with Screws Specifications E52-CA6D-N, E52-IC6D-N Element type K (CA), J (IC) Dimensions Class Class 2 (0.75) Protective tubing material SUS304 Taper screw for tube R1/8 (SUS304) Siliconized shrinkable tube Full-circled welding Shrinkable tube (CA:Blue, IC:Yellow) Product label Peel treatment Lead wire Protective tubing (SUS304) Thermal contact Grounded type Temperature range Lead wire Red (+) (16) 0°C to 350°C: K (CA) 0°C to 350°C: J (IC) Fluororesin-covered thermocouple wire (PFA) with external dimensions of 1.6 x 1.0 1/0.3 0°C to 150°C 4±0.05 dia. (30) 14 (10) (75) 80±10 (30) 65±2 White (−) (M-16) M±5% 15 Lead wire length (M): 1, 2, or 4 m Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Element type: K (CA) Element type: J (IC) Model 1 E52-CA6D-N 1M E52-IC6D-N 1M 2 E52-CA6D-N 2M E52-IC6D-N 2M 4 E52-CA6D-N 4M E52-IC6D-N 4M Exposed-lead Models Specifications E52-CA10AE-N, E52-IC10AE-N Element type K (CA), J (IC) Dimensions Class Class 2 (0.75) Protective tubing material SUS304 Fluorocarbon resin protective tubing Protective tubing 3.2±0.05 dia. (SUS304) Shrinkable tube (CA:Blue, IC:Yellow) Peel treatment Product label Red (+) Thermal contact Non-grounded type Temperature range 0°C to 350°C: K (CA) 0°C to 200°C: J (IC) Lead wire Fluororesin-covered thermocouple wire (PFA) with external dimensions of 1.6 x 1.0 1/0.32 0°C to 180°C Swage Lead wire (30) M±5% 100±5 Note: 1. 2. 3. 4. (10) (75) 80±10 White (−) The thermocouple is a single wire from the tip to the terminal. Lead wire length M: 1, 2, or 4 m The protective tubing is of pipe construction, which must not be bent. The thermocouple cannot be mounted using a PT@ Compression Fitting. Lead wire length (m) Element type: K (CA) Element type: J (IC) Model 1 E52-CA10AE-N 1M E52-IC10AE-N 1M 2 E52-CA10AE-N 2M E52-IC10AE-N 2M 4 E52-CA10AE-N 4M E52-IC10AE-N 4M 20 E52 Exclusive Models ■ Thermocouples Thermocouples for Molding Machines Specifications E52-CA2GVY, E52-IC2GVY Element type K (CA), J (IC) Dimensions Element diameter 1.0 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 Thermal contact Grounded type Temperature range 0°C to 350°C Lead wire Glass-covered stainless steel shielded thermocouple wire with 4 dia. 1/1.0 0°C to 180°C Spring retainer (Brass nickel plated) Bayonet (Brass nickel plated) Protective tubing (SUS304) Shrinkable tube (CA:Blue, IC:Yellow) Spring 15 dia. 6.8 dia. Product label Marking tube Red (Red) Lead wire 4.8±0.05 dia. 25±2 15 White/Red Stripes (+) White Marking tube (White) (80) 85±10 (30) 20 100±10 Crimping terminal Y type for M3.5 CA: White/Blue Stripes (−) IC: White/Yellow Stripes (−) M±5% Taper screw for tube R1/8 (Brass nickel plated) Note: The Adapter is included with the Thermocouple. If it is lost or damaged, you can order a replacement with the following model number. Adapter: Y92F-S1 8 dia.12 dia. 10 5 dia. 10 15 Details of mounting bracket Lead wire length (m) Element type: K (CA) Lead wire length (M): 1 or 2 m Element type: J (IC) Model 1 E52-CA2GVY 1M E52-IC2GVY 1M 2 E52-CA2GVY 2M E52-IC2GVY 2M Thermocouples with Crimp Terminals Specifications E52-CA1GTY, E52-IC1GTY Element type K (CA), J (IC) Dimensions Element diameter 0.65 mm (single wire) Class Class 2 (0.75) Thermal contact Grounded type Temperature range 0°C to 300°C Lead wire Glass-covered stainless steel shielded thermocouple wire with 4 dia. 1/1.0 0°C to 150°C Terminal shape Crimping terminal Y type for M3.5 Temperature measuring junction Marking tube (White) Shrinkable tube (CA:Blue, IC:Yellow) Crimping terminal round type for M4 (N1.25-4) Transparent vinyl tube Siliconized shrinkable tube White/Red Stripes (+) Product label 8 4.3 dia. Max. 6 dia. Lead wire Transparent 15±5 30±5 White (−) (80) 90±10 M±4% Lead wire length (M): 1 or 2 m Y-type crimp terminal for M3.5 Note: The E52-CA1GTY is also available with double elements. Refer to page 29 for details. Lead wire length (m) Element type: K (CA) Element type: J (IC) Model 1 E52-CA1GTY 1M E52-IC1GTY 1M 2 E52-CA1GTY 2M E52-IC1GTY 2M 21 E52 ■ Platinum Resistance Thermometers Platinum Resistance Thermometers for Surface Temperature Measurement Specifications E52-P2GSY Element type Pt100 Dimensions Class Class B Protective tubing material SUS304 With brass-nickelplated bracket Conductor type 3-conductor system Temperature range −50°C to 250°C Lead wire Silicone-covered 3-conductor cable and approx. 3.9 dia. 30/0.08 −50°C to 150°C Blacket (Brass nickel plated) 4×3.2 dia. Siliconized shrinkable tube (7.5 dia.) Lead wire 3 Crimping terminal Y type for M3.5 Marking tube (White) Shrinkable tube Product label (Black) Red (A) White (B) 5 20±1 White (B) 14±0.5 Transparent 20±0.5 1.5 4.5 30±5 (50) 6 28±1 (30) (80) M±4% Lead wire length (m) 90±10 Lead wire length (M): 1 or 2 m Model 1 E52-P2GSY 1M 2 E52-P2GSY 2M Platinum Resistance Thermometers for Room Temperature Measurement Specifications E52-P10GRY Element type Pt100 Dimensions Class Class B Protective tubing material SUS304 Conductor type 3-conductor system Temperature range −50°C to 60°C Lead wire Vinyl-covered 3-conductor cable with 6.1 dia. 20/0.18 −25°C to 60°C Product label Terminal box 85 2×8 dia. 60 70±1 42±1 69.5±1 Protective piping (Brass nickel plated) Crimping terminal Y type for M3.5 Chain Marking tube (Red) Protective tubing (SUS304) Red Shrinkable tube (Black) 56±1 22.2±1 dia. 8 dia. Red (A) White (B) 4.8 dia. Black (B) Lead wire 4.5±1 (30) (95) 100±4 97±1 Lead wire length (m) 2 White Marking tube (White) (80) 85±10 M±5% Model E52-P10GRY 2M Waterproof Platinum Resistance Thermometers Specifications E52-P10GPY Element wire Pt100 Class Class B Protective tubing material SUS304 Conductor type Vinyl-covered 3-conductor cable with 6.1 dia. 12/0.18 −25°C to 60°C Resistive pressure 981 kps Crimping terminal Y type for M3.5 Shrinkable tube (Black) Protective tubing (SUS304) Marking tube (Red) Sleeve (SUS304) Full-circled Welding 3-conductor system Temperature range 0°C to 70°C (underwater) −20°C to 70°C (in the air) Lead wire Dimensions Red Lead wire Product label Red (A) White (B) 7±0.2 dia. 20 dia. White Marking tube (White) (30) (80) 85±10 M±5% 12 100±2 62 5 Black (B) Lead wire length (M): 1 or 2 m Note: The lead wires are vinyl-covered, and cannot be used underwater. Use the E52-P5AY-40 if waterproof lead wires are required for use underwater. Refer to page 24 for details. Lead wire length (m) Model 2 E52-P10GPY 2M 4 E52-P10GPY 4M 22 E52 Corrosion-resistant Models with Fluororesin-covered Protective Tubing ■ Thermocouples Exposed-lead Models Specifications E52-CA20AY-1 Element type K (CA) Class Class 2 (0.75) Protective tubing material ASTM316L with Fluororesin-covered (FEP) tube Thermal contact Non-grounded type Temperature range 0°C to 180°C Lead wire Vinyl-covered: −20°C to 70°C Dimensions Sheath (ASTM316L) Ds±0.05 Shrinkable tube (CA:Blue, IC:Yellow) Fixed with adhesive tape and siliconized shrinkable tube Crimping terminal Y type for M3.5 Marking tube (White) Sleeve (SUS304) FEP-covered tubing Product label d Red (+) White (−) D±0.1 5 22 +9 -5 Lead wire 8 Transparent 30±5 (L-5) L Model +4 0 Protective tubing diameter E52-CA20AY-1 D=4.6 2M D = 4.6 E52-CA20AY-1 D=6 2M D = 6.0 E52-CA20AY-1 D=8 2M D = 8.0 (80) 90±10 M±4% 55 Sleeve diameter (mm) Sleeve length (mm) tube thickness (mm) d=8 l = 55 0.7 d = 11 l = 55 0.8 Lead wire length (m) 0.5 0.6 ■ Platinum Measurement Exposed-lead Models Specifications E52-P20AY-1 Element type Pt100 Class Class B Protective tubing material SUS316 with Fluororesin-covered (FEP) tube Conductor type 3-conductor system Temperature range −80°C to 180°C Lead wire Vinyl-covered: −20°C to 70°C Dimensions Crimping terminal Y type for M3.5 Fixed with adhesive tape and Tube nose shape : siliconized shrinkable tube Round Marking tube Sheath (SUS316) Shrinkable tube (Black) (Red) FEP-covered tubing Red Sleeve (SUS304) Product label Lead wire Red (A) White (B) D±0.1 Ds±0.05 (10) A Black (B) 8 dia. (10) (20) L+5 ±3% Model (30) 35 M±4% Protective tubing diameter Marking tube White (White) (80) 85±10 Sleeve diameter (mm) Coating thickness (mm) E52-P20AY-1 D=4.6 2M D = 4.6 d=8 0.7 E52-P20AY-1 D=6 2M D = 6.0 d=8 0.6 E52-P20AY-1 D=8 2M D = 8.0 d=8 0.8 Lead wire length (m) 2 23 E52 FEP-molded Models (Completely Waterproof) Specifications E52-P5AY-40 Element type Pt100 Class Class B Protective tubing material Fluororesin (FEP) tube (element / fluororesin mold (FEP)) Conductor type 3-conductor system Temperature range −50°C to 180°C Lead wire Fluororesin (FEP) cover (with outer cover): −50°C to 180°C Dimensions Crimping terminal Y type for M3.5 Fusion (Completely waterproof) +0.1 6 -0.5 dia. Lead wire FEP tube Transparent Shrinkable tube (Black) Product label Marking tube (White) Red (A) White (B) White (B) +4 30±5 65 -1 (80) 90±10 M±4% Model Lead wire length (m) E52-P5AY-40 2M 2 E52-P5AY-40 4M 4 E52-P5AY-40 6M 6 E52-P5AY-40 8M 8 24 E52 Pressure-resistant Explosion-proof (IICT6) Models ■ Thermocouples Enclosed-terminal Models E52-CA@@C-N-6 Dimensions (131.5) Explosion-proof display label Back: Product label 110 L L2±3% L1=50 Official approval success label Socket (SUS304) Support (SUS304) Sheath (ASTM316L) 15 dia. (113) 6.4±0.05 dia. Full-circled Welding Cap Terminal box Chain (64.5) Pressure-resistant explosion-proof cable ground (Adopted cable diameter: for 9-10 dia.) 70 (10) Specifications Element type K (CA) Class Class 2 (0.75) Class 3 (Level 1.5) at 40°C and under Protective tubing material L2 section: ASTM316L L1 section: SUS304 Explosion- Construction Pressure-resistant proof explosion-proof structure specifica- Explosion-protected IICT6 tions class and ignitability Explosion-proof temperature range −20°C to 85°C Lead wire wiring method Pressure-resistant packing cable ground type Conduit thread G1/2 Installation method Conforms to Technical Recommendations of the Research Institute of Industrial Safety (Japan) Model Protective tubing length L (cm) Protective tubing diameter L2 (mm) E52-CA20C-N-6 D=6.4 L2=150 20 D = 6.4 150 E52-CA35C-N-6 D=6.4 L2=300 35 D = 6.4 300 E52-CA50C-N-6 D=6.4 L2=450 50 D = 6.4 450 E52-CA75C-N-6 D=6.4 L2=700 75 D = 6.4 700 25 E52 ■ Platinum Resistance Thermometers for Surface Temperature Measurement Enclosed-terminal Models E52-P@@C-N-6 Dimensions 110 L (131.5) Explosion-proof display label Back: Product label L2±3% L1=50 Official approval success label Socket (SUS304) 15 dia. Support (SUS304) Sheath (ASTM316L) (113) 6.4±0.05 dia. Full-circled Welding Cap Terminal box Chain (64.5) Pressure-resistant explosion-proof cable ground (Adopted cable diameter: for 9-10 dia.) 70 (10) Specifications Element type Pt100 Class Class B Protective tubing material L2 section: ASTM316L L1 section: SUS304 Explosion- Construction Pressure-resistant proof explosion-proof structure specifica- Explosion-protected IICT6 tions class and ignitability Explosion-proof temperature range −20°C to 85°C Lead wire wiring method Pressure-resistant packing cable ground type Conduit thread G1/2 E52-P20C-N-6 D=6.4 L2=150 20 D = 6.4 150 Conforms to Technical Recommendations of the Research Institute of Industrial Safety (Japan) E52-P35C-N-6 D=6.4 L2=300 35 D = 6.4 300 E52-P50C-N-6 D=6.4 L2=450 50 D = 6.4 450 E52-P75C-N-6 D=6.4 L2=700 75 D = 6.4 700 Installation method Model Protective tubing length L (cm) Protective tubing diameter L2 (mm) 26 E52 Double-element Models ■ Thermocouple Exposed-lead Models Specifications E52-CA20AY-7 Element type K (CA) Dimensions Class Class 2 (0.75) Thermal contact Non-grounded type Temperature range 0°C to permissible temperature limit Lead wire Vinyl-covered with external dimensions of 2.4 x 4.1 7/0.3 −20°C to 70°C Product label Sleeve (SUS304) Protective tubing ASTM316L material (with sheath) Sheath (ASTM316L) Crimping terminal Y type for M3.5 Transparent Marking tube (White) Shrinkable tube (Blue) Swage Lead wire 11 dia. D±0.05 30±5 L±3% Red (+) White (−) Red (+) White (−) (80) 90±10 M±4% 55 Permissible Temperature in Dry Air D Element wire K (CA) ASTM316L 3.2 dia. 750°C 4.8 dia. 800°C 6.4 dia. 800°C 8.0 dia. 900°C Model Protective tubing diameter Sleeve diameter (mm) Permissible Lead wire Temperature length (m) (°C) E52-CA20AY-7 D=3.2 2M D = 3.2 d = 11 750 2 E52-CA20AY-7 D=4.8 2M D = 4.8 d = 11 800 2 E52-CA20AY-7 D=6.4 2M D = 6.4 d = 11 800 2 E52-CA20AY-7 D=8.0 2M D = 8.0 d = 11 900 2 ■ Platinum Resistance Thermometers Exposed-lead Models Specifications E52-P20AY-7 Element type Pt100 Dimensions Class Class B Protective tubing ASTM316L material (with sheath) Conductor type 3-conductor system Temperature range −200°C to 450°C Lead wire Vinyl-covered with 6.5 dia. 19/0.18 −20°C to 70°C Wire mark (1,2) (White) Contradistinctive view Shrinkable tube (Black) Sleeve (SUS304) Sheath (ASTM316L) Marking tube (White) Product label Lead wire 11 dia. Swage D±0.05 Crimping terminal Y type for M3.5 Transparent Red (A) White (B) White/Black Stripes (B) Red (A) 1 2 White (B) 30±5 L±3% Model 55 (80) M±4% Protective tubing diameter White/Black Stripes (B) 90±10 Lead wire length (m) E52-P20AY-7 D=4.8 2M D = 4.8 2 E52-P20AY-7 D=6.4 2M D = 6.4 2 27 E52 Enclosed-terminal Models Specifications E52-P20C-N-7 Element type Pt100 Class Class B Protective tubing material ASTM316L (with sheath) Conductor type 3-conductor system Temperature range −200°C to 450°C Dimensions (92) Cap Product label Socket (SUS304) 38 dia. Swage 82 dia. Sheath (ASTM316L) D±0.05 (86) Chain G3/4 (Packing internal diameter : 12 dia.) (15) Terminal box 53 Model L-50±3% Protective tubing Protective length L (cm) tubing diameter E52-P20C-N-7 D=4.8 20 D = 4.8 E52-P20C-N-7 D=6.4 20 D = 6.4 Note: The length L is in centimeters, but “50” is 50 millimeters. Therefore, for the E52-P20C-N-7: L = 20 (cm), the sheath length L − 50 = 200 − 50 = 150 mm. 28 E52 Silicone-covered Lead Wires Models ■ Thermocouples Exposed-lead Models with Screws Specifications Element type K (CA) Class Class 2 (0.75) Screw material SUS304 Thermal contact Grounded type Temperature range 0°C to 300°C Lead wire Silicone-covered with external dimensions of 3.5 x 4.9 30/0.1 0°C to 150°C Terminal shape Y-type crimp terminal for M3.5 Note: Refer to the installation example for the E52-CA1DY. E52-CA1DY-40 Dimensions Screw (SUS304) Crimping terminal Y type for M3.5 Sleeve (Brass nickel plated) Marking tube (White) Protective spring (SUS304) Red 8±0.05 dia. Shrinkable tube (Blue) Red (+) 0.6 dia. +0.05 Lead wire 6.5 0 dia. Movable ring (Brass) End ring (Brass) 3.8±0.1 dia. B Blue 120° 13±1 2.8 +0.3 0 1±0.1 10 White (−) 80±5 0 -0.5 (20) A±0.3 (70) 80±10 M±1% C Model Screw pitch Lead wire length (m) E52-CA1DY-40 M6 1M M6 (P=1.0) 1 E52-CA1DY-40 M6 2M M6 (P=1.0) 2 E52-CA1DY-40 M6 4M M6 (P=1.0) 4 Thermocouples with Crimp Terminals Specifications Element type K (CA) Class Class 2 (0.75) Thermal contact Grounded type Temperature range 0°C to 200°C Lead wire Silicone-covered compensating cable with external dimensions of 3.2 x 4.6 30/0.1 0°C to 150°C Terminal shape Y-type crimp terminal for M3.5 E52-CA1GTY-14 Dimensions Crimping terminal round type for M4 (N1.25-4) Siliconized shrinkable tube Shrinkable tube (CA:Blue, IC:Yellow) 6.6 Max. 7 dia. Crimping terminal Y type for M3.5 Transparent Marking tube (White) Red (+) Product label Lead wire Lead wire length (M): 1 or 2 m 4.3 dia. White (−) 15±5 30±5 (80) 90±10 Model Lead wire length (m) E52-CA1GTY-14 1M 1 E52-CA1GTY-14 2M 2 M±4% 29 E52 Thermistors Element Interchangeable Thermistor for E5CS and E5C2 Temperature Ranges Temperature range Color code Nominal resistance Thermistor constant −50°C to 50°C Blue 6 kΩ (0°C) 3390K 0°C to 100°C Black 6 kΩ (0°C) 3390K 50°C to 150°C Red 30 kΩ (0°C) 3450K 100°C to 200°C Yellow 0.55 kΩ (200°C) 4300K 150°C to 300°C Green 4 kΩ (200°C) 5133K Lead wire A pair of 0.12 dia. 7 Fluororesin-insulated stranded wires with 0.86 outer dia. each Flat glass-wool-shielded lead cable with 0.12 dia. 10 conductors and external dimensions of 2.5 × 1.55 Specifications Item Coupling method E52-THE@@ Element interchangeable thermistor Class JIS class 1 Protective tubing material SUS304 Time constant 8 to 15 s in still water Dissipation factor 2.4 to 2.8 mW/°C in still air Lead wire heat resistive temperature 180°C Error Detectable temperature Error −50°C to 100°C ±1°C max. 100°C to 350°C ±1% max. of detectable temperature Permissible Temperature Detectable temperature Operating temperature −50°C to 50°C 100°C 0°C to 100°C 150°C 50°C to 150°C 200°C 100°C to 200°C 250°C 150°C to 300°C 350°C Note: Models with non-standard lead wire length and protective tubing length are available on request. This Thermistor is a dedicated Thermistor for the E5C2 and E5CS. 30 E52 Exposed-lead Models E52-THE5A Dimensions Temperature range Protective tubing (SUS304) Protective tube Lead wire Swage 4±0.08 dia. (5) (4) Transparent Peel treatment Marking tube (15) (10) (50) M±5% 50±1 Model −50°C to 50°C E52-THE5A −50-50°C 1M 0°C to 100°C E52-THE5A 0-100°C 1M 50°C to 150°C E52-THE5A 50-150°C 1M 100°C to 200°C E52-THE5A 100-200°C 1M 150°C to 300°C E52-THE5A 150-300°C 1M Note: The lead wires have no polarity Exposed-lead Models with Screws E52-THE6D Dimensions Protective tubing (SUS304) 10 6 Protective tube Swage 4±0.08 dia. Lead wire Marking tube Peel treatment Transparent (16) Tapered screw for tube R1/8 14 (5) (SUS304) 65±1 (4) (15) (15) (50) (10) Temperature range Model −50°C to 50°C E52-THE6D −50-50°C 1M 0°C to 100°C E52-THE6D 0-100°C 1M 50°C to 150°C E52-THE6D 50-150°C 1M 100°C to 200°C E52-THE6D 100-200°C 1M 150°C to 300°C E52-THE6D 150-300°C 1M M±5% Note: The lead wires have no polarity Exposed-lead Models with Flange E52-THE6F Dimensions Flange (SUS304) 3×3.5 dia. 120° 120° Protective tubing (SUS304) Swage 65±1 (4) (15) Peel treatment Lead wire (15) (5) 20 dia. 30 dia. Marking tube Transparent Protective tube (1) 4±0.08 dia. Temperature range Silver brazing (50) Model −50°C to 50°C E52-THE6F −50-50°C 1M 0°C to 100°C E52-THE6F 0-100°C 1M 50°C to 150°C E52-THE6F 50-150°C 1M 100°C to 200°C E52-THE6F 100-200°C 1M 150°C to 300°C E52-THE6F 150-300°C 1M (10) M±5% Note: The lead wires have no polarity Note: 1. The Thermistor lead cable can be extended with a standard lead wire for extension. 2. Be sure to specify the model and temperature range when ordering the Thermistor. The Thermistor has a color code according to the temperature range. 31 E52 (Ferrule) General-purpose Models (with Ferrule) ■ Model Number Legend The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below. Platinum Resistance Thermometers 1. Element type P: Pt100 2. Protective tubing length (L) Specify the length in centimeters within the following range: Unit (cm) E52-P@AF Diameter (D) Length (L) 3.2 7 to 100 4.8 10 to 600 6.4 13 to 1,300 4. Diameter 3.2: 3.2-mm dia. (Protective tubing construction: Sheathed) E52-@@AF only 4.8: 4.8-mm dia. (Protective tubing construction: Sheathed) E52-@@AF only 6.4: 6.4-mm dia. (Protective tubing construction: Sheathed) E52-@@AF only 5. Heat resistance Code 3. Terminal AF: Exposed lead wires (with Ferrule) Temperature range Lead type --- −20°C to 70°C Sleeve: 0°C to 70°C Vinyl-covered NETU 0°C to 180°C Sleeve: 0°C to 100°C Glass-wool-covered, externally shielded with stainless Specify for E52-P@AF model only. 6. Lead length (M) Specify the length in meters within the following range for the E52@@AF only: Range: 0.5, 1 to 100 m Examples Element: Pt100, protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m E52-P42AF D=4.8 NETU 10M ■ Sheathed Platinum Resistance Thermometers Refer to Model Number Legend above for the Pt100. Specifications Element type Pt100 Class JIS class B Sheath material SUS316 (E52-P@AF) ASTM316L (E52-P@B-N, E52-P@C-N) Sheath outer diameter 3.2 dia., 4.8 dia., 6.4 dia., 8 dia Conductor type 3-conductor system Temperature range −196°C to 450°C (in dry air) 32 E52 (Ferrule) Exposed-lead Models E52-P@AF Dimensions Lead Wire Ferrule * SUS304 sleeve Sheath (SUS316) Shrinkable tube (black) Caulking D±0.05 8 dia. • Standard (−20°C to 70°C): Fully vinyl-covered with twelve 0.18-dia conductors (0.3 mm thick) and 4.8 mm in outer dia. The sleeve resists a temperature range between 0°C and 70°C. • Heat Resistive (0°C to 180°C): Fully glass-wool-covered with thirty 0.12-dia. conductors (0.3 mm thick) externally shielded with stainless steel, 4 mm in outer dia. The sleeve resists a temperature range between 0°C and 100°C. • Lead Wire Length (M): 1, 2, 4, or 8 m Turquoise Product label Lead wire Maker tube Red (A) A B White (B) B Black (B) (30) 40 L±3% M±4% 85±10 * Ferrule Dimensions Cross-sectional diameter: 2 mm max. Length: 9 mm max. Model Information Custom-made models are available on request. Refer to page 32 for details. Terminal type Protective tubing diameter D (mm) Exposed-lead 3.2 dia. Models Protective tubing length L (cm) 15 20 35 4.8 dia. 20 35 50 Lead wire type Lead wire length M (m) 1 2 4 8 Model Standard E52-P15AF D=3.2 E52-P15AF D=3.2 E52-P15AF D=3.2 E52-P15AF D=3.2 1M 2M 4M 8M Heat resistive E52-P15AF D=3.2 E52-P15AF D=3.2 E52-P15AF D=3.2 E52-P15AF D=3.2 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P20AF D=3.2 E52-P20AF D=3.2 E52-P20AF D=3.2 E52-P20AF D=3.2 1M 2M 4M 8M Heat resistive E52-P20AF D=3.2 E52-P20AF D=3.2 E52-P20AF D=3.2 E52-P20AF D=3.2 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P35AF D=3.2 E52-P35AF D=3.2 E52-P35AF D=3.2 E52-P35AF D=3.2 1M 2M 4M 8M Heat resistive E52-P35AF D=3.2 E52-P35AF D=3.2 E52-P35AF D=3.2 E52-P35AF D=3.2 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P20AF D=4.8 E52-P20AF D=4.8 E52-P20AF D=4.8 E52-P20AF D=4.8 1M 2M 4M 8M Heat resistive E52-P20AF D=4.8 E52-P20AF D=4.8 E52-P20AF D=4.8 E52-P20AF D=4.8 NETU 1M NETU 2M NETU 4M NETU 8M Standard E52-P35AF D=4.8 E52-P35AF D=4.8 E52-P35AF D=4.8 E52-P35AF D=4.8 1M 2M 4M 8M Heat resistive E52-P35AF D=4.8 E52-P35AF D=4.8 E52-P35AF D=4.8 E52-P35AF D=4.8 NETU 1M NETU 2M NETU 4M NETU 8M E52-P50AF D=4.8 E52-P50AF D=4.8 E52-P50AF D=4.8 E52-P50AF D=4.8 8M 4M 1M 2M Standard Heat resistive E52-P50AF D=4.8 E52-P50AF D=4.8 E52-P50AF D=4.8 E52-P50AF D=4.8 NETU 1M NETU 2M NETU 4M NETU 8M 33 E52 (Ferrule) ■ Model Number Legend The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below. Thermocouples 1. Element type CA:K 2. Protective tubing length (L) Specify the length in centimeters in the following range: Unit (cm) E52-CA@AF (Exposed-lead Model) Diameter (D) Length (L) 1 2 to 200 1.6 3 to 500 3.2 5 to 2,000 4.8 8 to 2,300 6.4 10 to 1,200 8 12 to 1,000 3. Terminal AF: Exposed lead wires (with Ferrule) (element type: K, J) 4. Diameter Specify the protective tubing material according to the table. Code Diameter Protective tubing (D) construction Protective tubing material 1 1 mm Sheathed ASTM316L 1.6 1.6 mm Sheathed ASTM316L 3.2 3.2 mm Sheathed ASTM316L 4.8 4.8 mm Sheathed ASTM316L 6.4 6.4 mm Sheathed ASTM316L 8 8 mm Sheathed ASTM316L 5. Heat resistance Specify this item for the exposed-lead models only. Code Temperature range Lead type --- −20°C to 70°C Sleeve: 0°C to 70°C Vinyl-covered NETU 0°C to 150°C Sleeve: 0°C to 100°C Glass-wool-covered with external shield of stainless 6. Lead length (M) Specify the length in meters in the following range for the E52-CA@AF only. Range: 1 to 100 m 7. Protective tubing material Code --- Protective tubing material ASTM316L Element type K Examples Element: K; protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m E52-CA@AF D=4.8 NETU 10M 34 E52 (Ferrule) ■ Sheathed Thermocouples Specifications Permissible Temperature in Dry Air D Element type K (CA) Class JIS class 2 (0.75) Thermal contact Non-grounded type Sheath material CA: ASTM316L Element wire K (CA) ASTM316L IC: ASTM316L 1 dia. 650°C 1.6 dia. 650°C 3.2 dia. 750°C 4.8 dia. 800°C 6.4 dia. 800°C 8.0 dia. 900°C Note: For details on the permissible temperature, refer to page D-5 of Introduction of Temperature Controllers (Cat. No. H900). Exposed-lead Models E52-CA@AF Dimensions Sheath (ASTM316L) Shrinkable tube (blue) SUS304 sleeve Ferrule * White Maker tube Red (+) Product label Caulking D±0.05 d Lead wire * Ferrule Dimensions Cross-sectional diameter: 2 mm max. Length: 9 mm max. White (−) (80) 30±5 L±3% 55 M±4% 90±10 Note: 1. Lead Wire (Compensating Conductor) • Standard (−20°C to 70°C): Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm thick) and external dimensions of 2.4 × 4.1. • Heat Resistive (0°C to 150°C): Fully glass-wool-covered with seven 0.3-dia. conductors (0.5 mm thick) with external shield of stainless steel and external dimensions of 2.8 × 4.6 The heat-resistive lead wires cannot be used in locations exposed to water or other liquids. • Lead Wire Length (M): 1, 2, 4, or 8 m 2. The sleeve resists temperatures ranging between −20°C and 70°C for standard models and 0°C and 100°C for heat-resistive models. Permissible Temperature in Dry Air D Unit (mm) D d Element wire J (IC) ASTM316L l 1 dia. 8 55 1 dia. 450°C 1.6 dia. 8 55 1.6 dia. 450°C 3.2 dia. 8 55 3.2 dia. 650°C 4.8 dia. 8 55 4.8 dia. 750°C 6.4 dia. 11 55 6.4 dia. 750°C 8 dia. 11 55 8.0 dia. 750°C 35 E52 (Ferrule) K (CA) Model Information (E52-CA@AF) Model Information Custom-made models are available on request. Refer to Model Number Legend on page 34 for details. Terminal type Protective Protective tubing diameter tubing length L D (mm) (cm) Lead wire type Lead wire length M (m) 1 2 4 8 Model Exposed-lead Models 1 dia. 15 20 35 1.6 dia. 15 20 35 Exposed-lead Models 3.2 dia. 15 20 35 50 4.8 dia. 20 35 50 Standard E52-CA15AF D=1 1M E52-CA15AF D=1 2M E52-CA15AF D=1 4M E52-CA15AF D=1 8M Heat resistive E52-CA15AF D=1 NETU 1M Standard E52-CA20AF D=1 1M E52-CA20AF D=1 2M E52-CA20AF D=1 4M E52-CA20AF D=1 8M Heat resistive E52-CA20AF D=1 NETU 1M Standard E52-CA35AF D=1 1M E52-CA35AF D=1 2M E52-CA35AF D=1 4M E52-CA35AF D=1 8M Heat resistive E52-CA35AF D=1 NETU 1M E52-CA35AF D=1 NETU 2M E52-CA35AF D=1 NETU 4M E52-CA35AF D=1 NETU 8M Standard E52-CA15AF D=1.6 1M E52-CA15AF D=1.6 2M E52-CA15AF D=1.6 4M E52-CA15AF D=1.6 8M Heat resistive E52-CA15AF D=1.6 NETU 1M E52-CA15AF D=1.6 NETU 2M E52-CA15AF D=1.6 NETU 4M E52-CA15AF D=1.6 NETU 8M Standard E52-CA20AF D=1.6 1M E52-CA20AF D=1.6 2M E52-CA20AF D=1.6 4M E52-CA20AF D=1.6 8M Heat resistive E52-CA20AF D=1.6 NETU 1M E52-CA20AF D=1.6 NETU 2M E52-CA20AF D=1.6 NETU 4M E52-CA20AF D=1.6 NETU 8M Standard E52-CA35AF D=1.6 1M E52-CA35AF D=1.6 2M E52-CA35AF D=1.6 4M E52-CA35AF D=1.6 8M Heat resistive E52-CA35AF D=1.6 NETU 1M E52-CA35AF D=1.6 NETU 2M E52-CA35AF D=1.6 NETU 4M E52-CA35AF D=1.6 NETU 8M Standard E52-CA15AF D=3.2 1M E52-CA15AF D=3.2 2M E52-CA15AF D=3.2 4M E52-CA15AF D=3.2 8M Heat resistive E52-CA15AF D=3.2 NETU 1M E52-CA15AF D=3.2 NETU 2M E52-CA15AF D=3.2 NETU 4M E52-CA15AF D=3.2 NETU 8M Standard E52-CA20AF D=3.2 1M E52-CA20AF D=3.2 2M E52-CA20AF D=3.2 4M E52-CA20AF D=3.2 8M Heat resistive E52-CA20AF D=3.2 NETU 1M E52-CA20AF D=3.2 NETU 2M E52-CA20AF D=3.2 NETU 4M E52-CA20AF D=3.2 NETU 8M Standard E52-CA35AF D=3.2 1M E52-CA35AF D=3.2 2M E52-CA35AF D=3.2 4M E52-CA35AF D=3.2 8M Heat resistive E52-CA35AF D=3.2 NETU 1M E52-CA35AF D=3.2 NETU 2M E52-CA35AF D=3.2 NETU 4M E52-CA35AF D=3.2 NETU 8M Standard E52-CA50AF D=3.2 1M E52-CA50AF D=3.2 2M E52-CA50AF D=3.2 4M E52-CA50AF D=3.2 8M Heat resistive E52-CA50AF D=3.2 NETU 1M E52-CA50AF D=3.2 NETU 2M E52-CA50AF D=3.2 NETU 4M E52-CA50AF D=3.2 NETU 8M Standard E52-CA20AF D=4.8 1M E52-CA20AF D=4.8 2M E52-CA20AF D=4.8 4M E52-CA20AF D=4.8 8M Heat resistive E52-CA20AF D=4.8 NETU 1M E52-CA20AF D=4.8 NETU 2M E52-CA20AF D=4.8 NETU 4M E52-CA20AF D=4.8 NETU 8M Standard E52-CA35AF D=4.8 1M E52-CA35AF D=4.8 2M E52-CA35AF D=4.8 4M E52-CA35AF D=4.8 8M Heat resistive E52-CA35AF D=4.8 NETU 1M E52-CA35AF D=4.8 NETU 2M E52-CA35AF D=4.8 NETU 4M E52-CA35AF D=4.8 NETU 8M Standard E52-CA50AF D=4.8 1M E52-CA50AF D=4.8 2M E52-CA50AF D=4.8 4M E52-CA50AF D=4.8 8M Heat resistive E52-CA50AF D=4.8 NETU 1M E52-CA50AF D=4.8 NETU 2M E52-CA50AF D=4.8 NETU 4M E52-CA50AF D=4.8 NETU 8M E52-CA15AF D=1 NETU 2M E52-CA20AF D=1 NETU 2M E52-CA15AF D=1 NETU 4M E52-CA20AF D=1 NETU 4M E52-CA15AF D=1 NETU 8M E52-CA20AF D=1 NETU 8M 36 E52 (Ferrule) Low-cost Models (with Ferrule) ■ Low-cost Platinum Resistance Thermometers Exposed-lead Models with Screws Specifications E52-P6DF Element type Pt100 Dimensions Conductor type 3-conductor system Class Class B Protective tubing material SUS304 Sensor length 30 mm Max. detectable temperature 250°C Temperature range −50°C to 250°C Lead wire Fluororesin-covered wire (PFA) and approx. 1.0 dia. 7/0.18 −50°C to 150°C Tapered pipe thread Full-circled welding SUS304 R1/8 Silicon SUS304 shrinkable tube protective 4 dia.±0.4 tubing Ferrule * Maker tube Lead wire Yellow Red (A) A B (16) Black (B) B White (B) 6±0.5 10±0.5 14 Product label (30) 65 0 -2 (M-16) M±5% 15 Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Model 1 E52-P6DF 1M 2 E52-P6DF 2M 4 E52-P6DF 4M * Ferrule Dimensions Cross-sectional diameter: 2 mm max. Length: 9 mm max. Exposed-lead Models with Flange Specifications E52-P6FF Element wire Pt100 Dimensions Conductor type 3-conductor system Class Class B Protective tubing material SUS304 Three, 3.5 dia. 120° 120° 4 dia.±0.4 Flange (SUS304) SUS304 protective tubing Ferrule * Nickel soldering Maker tube Silicon shrinkable tube Yellow Lead wire Red (A) A Sensor length 30 mm Max. detectable temperature 250°C Temperature range −50°C to 250°C Lead wire Fluororesin-covered wire (PFA) and approx. 1.0 dia. 7/0.18 −50°C to 150°C Black (B) B B White (B) Product label 1 20 dia. (30) 30 dia. 65 0 -2 (M-16) M±5% 15 Note: The protective tubing is of pipe construction, which must not be bent. Lead wire length (m) Model 1 E52-P6FF 1M 2 E52-P6FF 2M 4 E52-P6FF 4M * Ferrule Dimensions Cross-sectional diameter: 2 mm max. Length: 9 mm max. Exposed-lead Models Specifications E52-P10AEF Element type Pt100 Dimensions Conductor type 3-conductor system Class Class B Protective tubing material SUS316 Max. detectable temperature 250°C Temperature range 0°C to 250°C Lead wire Fluororesin-covered wire (PFA) and approx. 1.0 dia. 7/0.2 −50°C to 150°C Ferrule * Shrinkable tube (black) Product label Silicon SUS316 protective shrinkable tube 3.2±0.05 dia. tubing Maker tube Yellow Red (A) Lead wire A B White (B) B White (B) 30 30±5 80±10 M±4% 100±3% Note: 1. The protective tubing is of pipe construction, which must not be bent. 2. A Compression Fitting (PT@) cannot be used for mounting. Lead wire length (m) Model 1 E52-P10AEF 1M 2 E52-P10AEF 2M 4 E52-P10AEF 4M * Ferrule Dimensions Cross-sectional diameter: 1.5 mm max. Length: 9 mm max. 37 E52 (Ferrule) ■ Low-cost Thermocouples Exposed-lead Models with Screw E52-CA1DF Specifications Element type K (CA) Element dia. 0.65 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 Thermal contact Grounded type Temperature range 0°C to 400°C: K (CA) Lead wire Fully glass-woolcovered with external copper shield and external dimensions of approx. 3.1 x 2.0 1/0.65 0°C to 180°C Dimensions Movable ring (brass) C Sleeve Ferrule * Shrinkable tube Turquoise SUS304 (Brass-nickel plating) (CA: Blue, Top ring (brass) screw Protective IC: Yellow) Maker tube copper wire Lead wire + Terminal shape B Red (+) 5±0.05 dia. 120° 3.8±0.1 2.8 +0.3 0 1±0.1 0 10 -0.5 - 9±1 3.8±1 Black (−) (70) 80±10 (20) A±0.3 M±1% * Ferrule Dimensions Cross-sectional diameter: 1.5 mm max. Length: 9 mm max. Internal Construction (E52-CA1DF) 0.65-dia. black wire Movable ring Brass Ferrule Note: 1. The thermocouple is a single wire from the tip to the terminal. 2. Specify the type of screw (i.e., M6, M8, or W1/4) when ordering. 3. The thermocouple is not of airtight construction. 4. OMRON recommends that the tip of the thermocouple is touching the sensing object. Cut after silver soldering Closely wound enamel-bonded coil. M6 Brass pipe Screw Lead wire length (m) Screw W1/4 M6 M8 (P=1.27) (P=1.0) (P=1.25) A (mm) 4.3 4 B (mm) 11.5 11.5 5.3 15 C (mm) 10 10 13 Shielded glass-wool lead wire Installation Example Cut a thread into the workpiece, and screw in the thermocouple while pushing in so that the tip makes complete contact. End Workpiece Note: E52-CA1DF with the same shape and multiple element wires are also available (E52-CA1DF-40). Refer to page 42 for details. Protective tubing length (mm) Lead wire length (m) Element type: K (CA) Model M6 screw M8 screw W1/4 screw 1 E52-CA1DF M6 1M 2 E52-CA1DF M6 2M 4 E52-CA1DF M6 4M 1 E52-CA1DF M8 1M 2 E52-CA1DF M8 2M 4 E52-CA1DF M8 4M 1 E52-CA1DF W1/4 1M 2 E52-CA1DF W1/4 2M 4 E52-CA1DF W1/4 4M 38 E52 (Ferrule) Exclusive Models (with Ferrule) ■ Thermocouples Thermocouples for Molding Machines Specifications E52-CA2GVF Element type K (CA) Dimensions Element diameter 1.0 mm (single wire) Class Class 2 (0.75) Protective tubing material SUS304 Spring retainer Bayonet (Brass-nickel plating) (Brass-nickel plating) SUS304 protective 15 dia. tubing Product label Spring Shrinkable tube (Blue) Ferrule * Marker White tube Lead wire 4.8±0.05 dia. Thermal contact Grounded type 0°C to 350°C Lead wire Glass-covered stainless steel shielded thermocouple wire with 4 dia. 1/1.0 0°C to 180°C R1/8 White/red stripe (+) 8 dia.12 dia. + − Temperature range 5 dia. 25±2 15 6.8 20 dia. 100±10 (30) (80) 85±10 M±5% Lead wire length (m) Element type: K (CA) Model 1 E52-CA2GVF 1M 2 E52-CA2GVF 2M CA: White/blue stripe IC: White/yellow stripe (−) 10 10 15 Note: The Adapter is included with the Thermocouple. If it is lost or damaged, you can order a replacement with the following model number. Adapter: Y92F-S1 * Ferrule Dimensions Cross-sectional diameter: 2 mm max. Length: 9 mm max. Thermocouples with Crimp Terminals Specifications E52-CA1GTF Element type K (CA) Dimensions Element diameter 0.65 mm (single wire) Class Class 2 (0.75) M4, round crimp terminal (N1.25-4) Thermal contact Grounded type Temperature range 0°C to 300°C Lead wire Glass-wool-braided shield with maximum external dimensions of 2.6 x 4.0 1/0.65 0°C to 150°C Terminal shape Shrinkable tube (Blue) Silicone shrinkable tubing Lead wire 6.6 Ferrule * Marker tube Product label White/red stripe (+) + Turquoise Sensing point 4.3 dia. − White stripe (−) 6 dia. max. (80) 30±5 15±5 90±10 M±4% Lead wire length (m) Ferrule Note: The E52-CA1GTF is also available with double elements. Refer to page 42 for details. Element type: K (CA) Model 1 E52-CA1GTF 1M 2 E52-CA1GTF 2M * Ferrule Dimensions Cross-sectional diameter: 1.5 mm max. Length: 9 mm max. ■ Platinum Resistance Thermometers Platinum Resistance Thermometers for Surface Temperature Measurement Specifications E52-P2GSF Element type Pt100 Dimensions Class Class B Protective tubing material SUS304 With brass-nickelplated bracket Conductor type 3-conductor system Temperature range −50°C to 250°C Lead wire Silicone-covered 3-conductor cable and approx. 3.9 dia. 30/0.08 −50°C to 150°C Brass-nickel-plated bracket Silicon Four, 3.2 dia. shrinkable tube (7.5-dia.) 3 5 1.5 4.50 6 Ferrule * Lead wire Product label Shrinkable tube (Black) Marker tube Yellow Red (A) A B 20±1 White (B) B 14±0.5 White (B) 20±0.5 30±5 (50) 28±1 Lead wire length (m) (30) M±4% Model 1 E52-P2GSF 1M 2 E52-P2GSF 2M (80) 90±10 * Ferrule Dimensions Cross-sectional diameter: 1.5 mm max. Length: 9 mm max. 39 E52 (Ferrule) Platinum Resistance Thermometers for Room Temperature Measurement Specifications E52-P10GRF Element type Pt100 Class Class B Protective tubing material SUS304 Conductor type 3-conductor system Dimensions Product label Terminal box 85 Two, 8 dia. 60 42±1 70±1 dia. Temperature range −50°C to 60°C Lead wire Vinyl-covered 3-conductor cable with 6.1 dia. 20/0.18 −20°C to 60°C 69.5±1 22.2±1 dia. Protective pipe (Brass-nickel plating) 8.0 dia. SUS304 protective tubing Chain Ferrule * Lead wire 56±1 White Shrinkable tube (Black) Red (A) A B White (B) B Black (B) 4.8 dia. Marker tube 4.5±1 (30) (95) 100±4 97±1 M±5% Lead wire length (m) 2 (80) 85±10 * Ferrule Dimensions Cross-sectional diameter: 2 mm max. Length: 9 mm max. Model E52-P10GRF 2M Waterproof Platinum Resistance Thermometers Specifications E52-P10GPF Element wire Pt100 Class Class B Protective tubing material SUS304 Conductor type 3-conductor system Temperature range 0°C to 70°C (underwater) −20°C to 70°C (in the air) Lead wire Vinyl-covered 3-conductor cable with 6.1 dia. 12/0.18 −25°C to 60°C Resistive pressure 10 kg/cm2 max. Dimensions Full-circled welding Sleeve (SUS304) SUS304 protective tubing Shrinkable tube Ferrule * (Black) Product label Marker tube White 20 dia. Red (A) Lead wire A 7±0.2 dia. White (B) B B Black (B) (30) 12 (80) 85±10 100±10 62 5 M±5% Note: The lead wires are vinyl-covered, and cannot be used underwater. Use the E52-P5AF-40 if waterproof lead wires are required for use underwater. Refer to page 41 for details. * Ferrule Dimensions Cross-sectional diameter: 2 mm max. Length: 9 mm max. Lead wire length (m) Model 2 E52-P10GPF 2M 4 E52-P10GPF 4M 40 E52 (Ferrule) Corrosion-resistant Models with Fluororesin-covered Protective Tubing (with Ferrule) FEP-molded Models (Completely Waterproof) Specifications E52-P5AF-40 Element type Pt100 Class Class B Protective tubing material Fluororesin (FEP) tube (element / fluororesin mold (FEP)) Conductor type 3-conductor system Temperature range −50°C to 180°C Lead wire Fluororesin (FEP) cover (with outer cover): −50°C to 180°C Dimensions Fused (completely waterproof) FEP-covered tubing 6 +0.1 −0.5 dia. Shrinkable tube (Black) Ferrule * Product label Marker tube White Lead wire Red (A) A B B 65 +4 −1 30±5 White (B) White (B) (80) 90±10 M±4% Model Lead wire length (m) E52-P5AF-40 2M 2 E52-P5AF-40 4M 4 * Ferrule Dimensions Cross-sectional diameter: 2 mm max. Length: 9 mm max. 41 E52 (Ferrule) Silicone-covered Lead Wires Models (with Ferrule) ■ Thermocouples Exposed-lead Models with Screws Specifications Element type K (CA) Class Class 2 (0.75) Screw material SUS304 Thermal contact Grounded type Temperature range 0°C to 300°C Lead wire Silicone-covered (0.1/30): 0°C to 150°C Terminal shape Ferrule Note: Refer to the installation example for the E52-CA1DY. E52-CA1DF-40 Dimensions Sleeve (Brass-nickel plating) Movable ring (brass) SUS304 screw Top ring (Brass) Protective spring (SUS304) 8±0.05 dia. 120° 6.5 +0.05 dia. 0 * Ferrule Dimensions Cross-sectional diameter: 1.5 mm max. Length: 9 mm max. Ferrule * Yellow Shrinkable tube (Blue) Maker tube Lead wire Red (+) + Model 3.8±0.1 2.8 1±0.1 10 − 0.6 dia. +0.3 0 13±1 E52-CA1DF-40 M6 1M M6 (P=1.0) 1 E52-CA1DF-40 M6 2M M6 (P=1.0) 2 80±10 E52-CA1DF-40 M6 4M M6 (P=1.0) 4 White (−) (20) A±0.3 Lead wire length (m) (70) 80±5 0 −0.5 Screw pitch M±1% Thermocouples with Crimp Terminals Specifications Element type K (CA) Class Class 2 (0.75) Thermal contact Grounded type Temperature range 0°C to 200°C Lead wire Silicone-covered : 0°C to 150°C Terminal shape Ferrule E52-CA1GTF-14 Dimensions M4, round, crimp terminal (N1.25-4) 6.6 Ferrule * Shrinkable tube (Blue) Silicone shrinkable tubing Lead wire 7 dia. max. Maker tube Red (+) Product label + Sensing point − 4.3 dia. 15±5 Yellow 30±5 * Ferrule Dimensions Cross-sectional diameter: 1.5 mm max. Length: 9 mm max. Model White (−) Lead wire length (m) (80) E52-CA1GTF-14 1M 1 90±10 E52-CA1GTF-14 2M 2 M±4% Lead wire length (M): 1 or 2 m 42 E52 (Ferrule) Accessories Compression Fittings Model Information Model Screw of part Applicable a protective tubing diameter PT 1/8 D=1.0 R 1/8 1.0 dia. PT 1/8 D=1.6 1.6 dia. PT 1/8 D=3.2 3.2 dia. PT 1/8 D=4.8 Dimension b c d Flat diameter Part c Part b 5 13 10 14 14 5 15 12 17 14 4.8 dia. PT 1/4 D=3.2 R 1/4 3.2 dia. PT 1/4 D=4.8 4.8 dia. PT 1/4 D=6.4 6.4 dia. PT 3/8 D=8 R 3/8 8 dia. 5 19 15 21 17 PT 1/2 D=10 R 1/2 10 dia. 15.1 8 19 22 19 M 12 D=4.8 M 12 4.8 dia. 5 15 12 17 14 Note: The Compression Fitting is not of airtight construction. Do not use the Compression Fitting for applications in which the exposure of the sensing object will cause problems. The compression fitting is a screw that adjusts and secures the insertion length of Temperature Sensors with the above protective tubing diameters. The material of the Compression Fitting is SUS304 with internal fixing beads made of brass. a Sensor side Head side d c b Source: JIS B 0203 (Unit: mm) <R1/8, 1/4, R3/8> Tighten using the retaining screw to secure to the protective tubing. Material Protective tubing dia. D Main body SUS304 Lock bead Brass Retaining screw SUS304 <1/2> Front ring SUS316 Nut SUS316 Nominal thread size T.P.I. Outer (No. of diamethreads ter: d /inch) Root diameter: d1 Standard diameter position a (from pipe end) Minimum effective screw length: f R 1/8 28 9.728 9.147 8.566 3.97 ±0.91 2.5 R 1/4 19 13.157 12.301 11.445 6.01 ±1.34 3.7 R 3/8 19 16.662 15.806 14.950 6.35 ±1.34 3.7 R 1/2 14 20.955 19.793 18.631 8.16 ±1.81 5.0 a f Back ring SUS316 Main body SUS316 Effective diameter: d2 Tapered thread d d2 d1 Standard dia. Loose Flanges Model Information Applicable protective tubing diameter Material: Aluminum Model 3.2 dia. MF-1 D=3.2 4.8 dia. MF-1 D=4.8 6.4 dia. MF-1 D=6.4 8 dia. MF-1 D=8 10 dia. MF-2 D=10 12 dia. MF-2 D=12 15 dia. MF-2 D=15 22 dia. MF-2 D=22 Note: 1. Use the Loose Flange in atmospheric pressure. The Loose Flange is not of airtight construction. 2. Use the Loose Flange at 400°C maximum. 3. Do not apply the Loose Flange to protective tubing diameters other than the applicable ones. MF-1 MF-2 120° 120° Three, 5 dia. Three, 6.5 dia. 36 54 dia. 21 dia. D dia. M4 31 dia. D dia. 5 14 24 23 dia. 45 dia. M6 6.6 35 dia. 70 dia. 43 E52 (Ferrule) Compensating Conductors The material of the Compensating Conductor is the same as or similar to that of the Thermocouple. Therefore, the Thermocouple can be connected to the Compensating Conductor just as if the length of the Thermocouple is to be extended. A standard model for a temperature range between −20°C and 70°C and two types of heat-resistive models for a temperature range between 0°C and 150°C are available. Be sure to use the compensating conductor for the extension of the length of the thermocouple. Model Information Thermocouple R Heat resistance Exterior Model (Length) 1m 2m 4m 8m Standard Fully vinyl-covered (waterproof) WPRG-N 1M WPRG-N 2M WPRG-N 4M WPRG-N 8M Heat resistive Fully glass-wool-covered WPRH-N 1M WPRH-N 2M WPRH-N 4M WPRH-N 8M Fully glass-wool-covered with external shield WPRH6-N 1M WPRH6-N 2M WPRH6-N 4M WPRH6-N 8M of stainless steel K (CA) Standard Fully vinyl-covered (waterproof) WCAG-N 1M WCAG-N 2M WCAG-N 4M WCAG-N 8M Heat resistive Fully glass-wool-covered WCAH-N 1M WCAH-N 2M WCAH-N 4M WCAH-N 8M Fully glass-wool-covered with external shield WCAH6-N 1M WCAH6-N 2M WCAH6-N 4M WCAH6-N 8M of stainless steel J (IC) Silicone-covered (See note 2.) WCAG-40 1M WCAG-40 2M WCAG-40 4M WCAG-40 8M Standard Vinyl covered (waterproof) WICG-N 1M WICG-N 2M WICG-N 4M WICG-N 8M Heat resistive Fully glass-wool-covered WICH-N 1M WICH-N 2M WICH-N 4M WICH-N 8M Fully glass-wool-covered with external shield WICH6-N 1M WICH6-N 2M WICH6-N 4M WICH6-N 8M of stainless steel Note: 1. Compensating Conductors with lengths, increased in units of a meter, up to 100 meters are available on request. Specify lengths above 100 meters in units of 100 meters. The maximum length depends on the product. Contact your OMRON representative for details. 2. It has the same waterproof characteristics as the standard model (fully vinyl-covered) and can be used at high temperatures. Specifications (JIS C1610-1995) Model WPRG-N Type of thermocouple R WPRH-N Use Code (See note.) K (CA) RCA-2-G Fully vinyl-covered (waterproof) 7/0.3 0 to 90 ±30 RCB-2-H Fully glass-wool-covered 0 to 150 ±60 ±100 7/0.32 Exterior color Black Standard KCC-2-G Fully vinyl-covered (waterproof) 7/0.3 0 to 90 Heat resistive KCB-2-H Fully glass-wool-covered 7/0.32 0 to 150 30/0.1 −20 to 150 ±100 ±140 Blue Fully glass-wool-covered with external shield of stainless steel WCAG-40 WICH6-N Error (°C) Heat resistive WCAH6-N WICG-N Operating temperature range (°C) Fully glass-wool-covered with external shield of stainless steel WCAH-N WICH-N Number of wires/wire diameter Standard WPRH6-N WCAG-N Exterior J (IC) Heat resistive KX-2-G for moving parts Silicone-covered Standard JX-2-G Fully vinyl-covered (waterproof) 7/0.3 −20 to 90 Heat resistive JX-2-H Fully glass-wool-covered 0 to 150 7/0.32 Yellow Fully glass-wool-covered with external shield of stainless steel Note: Symbols conform to JIS standards. For code having duplicate exterior, check the application and check in our models. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 44 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2016.6 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2016 All Right Reserved.