CSM_E52_DS_E_19_2
A Wide Variety of High-precision
Temperature Sensors
• Previous models with M3 screw connections have been joined
by new models with ferrules to help reduce wiring work.
• Ideal for the thermal input devices of Temperature Controllers.
• Select from a wide variety of Temperature Sensors according
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal.
Refer to Safety Precautions for All Temperature
Controllers.
Ordering Information
■ List of Models (Temperature Sensors)
Classification
Generalpurpose
Models
Description
Model and appearance
Sheathed E52-P@AY
platinum
resistance E52-P@C-N
thermometer
E52-P@B-N
−196°C to
450°C
Pt100
Sheathed
thermocouple
0°C to 900°C K (CA)
J (IC)
3-conduc- B
tor system
Protective
tubing
material
Terminal
type
Exposed 5
lead wires
ASTM316L
Enclosed
terminals
Nongrounded
type
2 (0.75)
Enclosed
terminals
ASTM316L
Exposed 9 to
lead wires 12
E52-CA@C-N
E52-IC@C-N
Enclosed
terminals
E52-CA@B-N
E52-IC@B-N
SUS316
E52-CA1DY
E52-IC1DY
0°C to
1,400°C
R (PR)
0°C to 250°C Pt100
−50°C to
250°C
0°C to 400°C K (CA)
J (IC)
2 (0.25)
3-conduc- B
tor system
13
14
Enclosed
terminals
15
JIS ceramic Enclosed
JIS special terminals
ceramic
16
SUS316
Exposed 17
lead wires
SUS304
Nongrounded
type
2 (0.75)
Grounded
type
E52-CA6F-N
E52-IC6F-N
E52-CA6D-N
E52-IC6D-N
E52-CA10AE-N
E52-IC10AE-N
7
Exposed
terminals
E52-CA@C-N
E52-IC@C-N
E52-CA@ASY
E52-IC@ASY
6
SUS316
Exposed
terminals
Low-cost E52-P10AEY
platinum
resistance E52-P6DY
thermomE52-P6FY
eter
Page
SUS316
E52-CA@B-N
E52-IC@B-N
E52-PR@C-N
Low-cost
thermocouple
Class
Exposed
terminals
0°C to 450°C
E52-CA@AY
E52-IC@AY
Conductor type
−196°C to
450°C
Standard E52-P@C-N
platinum
resistance
thermometer
Standard
thermocouple
Low-cost
Models
TemperaElement
ture range
type
(See note 3.)
18
19
20
Nongrounded
type
Note: 1. Exclusive models are provided on the following page.
2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use.
3. The temperature range varies with the material, thickness, construction, and element type of the protective tubing.
1
E52
Classification
Description
Model and appearance
Exclusive
Models
Bayonet
spring for
molding
machines
E52-CA2GVY
E52-IC2GVY
0°C to 350°C K (CA)
J (IC)
Crimping
terminals
E52-CA1GTY
E52-IC1GTY
0°C to 300°C
Used for
measuring surface
temperatures
E52-P2GSY
−50°C to
250°C
Conductor type
Class
Grounded 2 (0.75)
type
Pt100
3-conduc- B
tor system
−50°C to
60°C
Double-el- E52-CA20AY-7
ement
model
0°C to 900°C K (CA)
Two nongrounded
types
E52-P20AY-7
−196°C to
250°C
Two 3B
conductor
systems
E52-P20C-N-7
−200°C to
450°C
E52-P5AY-40
Corrosion- E52-P20AY-1
resistant
model
E52-CA20AY-1
Protective
tubing
material
SUS304
Terminal Page
type
Exposed 21
lead wires
---
Used for
E52-P10GRY
room temperature
measurement
WaterE52-P10GPY
proof model
Thermistors
TemperaElement
ture range
type
(See note 3.)
SUS304
22
Pt100
2 (0.75)
ASTM316L
27
Enclosed
terminals
0°C to 70°C
3-conductor system
SUS304
−50°C to
180°C
28
Exposed 22
lead wires
Fluororesin
tubing
24
SUS304
29
−80°C to
180°C
0°C to 180°C K (CA)
Nongrounded
type
Silicone- E52-CA1DY-40
covered
lead wires
0°C to 300°C
Grounded
type
E52-CA1GTY-14
0°C to 200°C
2 (0.75)
---
Explosion- E52-P@@C-N-6
proof model
---
Pt100
3-conduc- B
tor system
E52-CA@@C-N-6
---
K (CA)
Nongrounded
type
E52-THE5A
E52-THE6F
E52-THE6D
−50°C to
300°C
Thermistor
Element- 1
interchangeable
thermistor
ASTM316L
Enclosed
terminals
25
SUS304
Exposed 31
lead wires
2 (0.75)
Note: 1. General-purpose models and low-cost models are provided on the previous page.
2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use.
3. The temperature range varies with the material, thickness, construction, and element type of the protective tubing.
Use the temperature sensors with ferrule from the list on the next page.
2
E52
■ List of Models (Temperature Sensors with ferrule)
Classification
Generalpurpose
Models
Low-cost
Models
Exclusive
Models
Description
Model and appearance
TemperaElement
ture range
type
(See note 3.)
Sheathed
E52-P@AF
platinum resistance
thermometer
−196°C to
450°C
Sheathed E52-CA@AF
thermocou
ple
Pt100
Conductor type
Class
Protective
tubing
material
Terminal Page
type
3-conduc- B
tor system
SUS316
0°C to 900°C K (CA)
Nongrounded
type
ASTM316L
35 to
33
Low-cost
E52-P10AEF
platinum
resistance E52-P6DF
thermometer
E52-P6FF
0°C to 250°C Pt100
3-conduc- B
tor system
SUS316
37
Low-cost
thermocouple
E52-CA1DF
0°C to 400°C K (CA)
Grounded 2 (0.75)
type
Bayonet
spring for
molding
machines
E52-CA2GVF
0°C to 350°C K (CA)
Grounded 2 (0.75)
type
Crimping
terminals
E52-CA1GTF
0°C to 300°C
−50°C to
250°C
Used for
E52-P2GSF
measuring
surface temperatures
−50°C to
250°C
Used for
E52-P10GRF
room temperature measurement
−50°C to
60°C
Waterproof E52-P10GPF
model
0°C to 70°C
2 (0.75)
Silicone- E52-CA1DF-40
covered
lead wires
Pt100
38
SUS304
39
3-conduc- B
tor system
SUS304
40
0°C to 300°C K (CA)
E52-CA1GTF-14
SUS304
---
−50°C to
180°C
E52-P5AF-40
Exposed 33
lead wires
Grounded 2 (0.75)
type
0°C to 200°C
Fluororesin
tubing
41
SUS304
42
---
Note: 1. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use.
2. The temperature range varies with the material, thickness, construction, and element type of the protective tubing.
■ Accessories
It is recommended that the following accessories be used for mounting Temperature Sensors.
Accessory
Compression
Fitting
Temperature
range
600°C max.
Mounting example
Mounting with
Compression
Fitting
Page
43
Terminal box
Compression Fitting
PT screw
Welding
Loose Flange
400°C max.
Mounting with
Loose Flange
Loose Flange
Mounting screw
Protective tubing
Terminal box
Protective tubing
Note: The Compression Fitting is not of
airtight construction. Do not use
the Compression Fitting for
applications in which the exposure
of the sensing object will cause
problems.
Note: 1. Use the Loose Flange in
normal atmospheric pressure.
The Loose Flange is not of
airtight construction.
2. Use the Loose Flange at 400°C
max.
3. Do not apply the Loose Flange
to protective tubing diameters
other than the applicable ones.
3
E52
General-purpose Models
■ Model Number Legend
The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below.
Platinum Resistance Thermometers
E52-@@@ D=@@@M
1 2 3
4
5 6
1. Element type
P: Pt100
2. Protective tubing length (L)
Specify the length in centimeters within the following range:
Unit (cm)
E52-@@AY
Diameter (D)
Length (L)
3.2
7 to 100
4.8
10 to 600
6.4
13 to 1,300
4. Diameter
3.2: 3.2-mm dia. (Protective tubing construction: Sheathed)
E52-@@AY and E52-@@C-N only
4.8: 4.8-mm dia. (Protective tubing construction: Sheathed)
E52-@@AY and E52-@@C-N only
6.4: 6.4-mm dia. (Protective tubing construction: Sheathed)
E52-@@AY and E52-@@C-N only
8: 8-mm dia. (Protective tubing construction: Sheathed)
E52-@@B-N and E52-@@C-N only
10: 10-mm dia. (Protective tubing construction: Standard)
E52-@@C-N only
5. Heat resistance
E52-@@B-N
Code
Diameter (D)
8
Length (L)
Diameter (D)
Vinyl-covered
NETU
0°C to 180°C
Sleeve: 0°C to 100°C
Glass-wool-covered,
externally shielded with
stainless
Length (L)
3.2
12 to 100
4.8
15 to 600
6.4
18 to 1,300
8
21 to 100
10
26 to 100
Lead type
−20°C to 70°C
Sleeve: 0°C to 70°C
20 to 100
E52-@@C-N
Temperature range
---
Specify for E52-@@AY model only.
6. Lead length (M)
Specify the length in meters within the following range for the E52@@AY only:
Range: 0.5, 1 to 100 m
3. Terminal
AY: Exposed lead wires (Y-type crimp terminal for M3.5)
B-N: Exposed terminals
C-N: Enclosed terminals
Examples
Element: Pt100, protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m
E52-P42AY D=4.8 NETU 10M
■ Sheathed Platinum Resistance Thermometers
Refer to Model Number Legend above for the Pt100.
Specifications
Element type
Pt100
Class
JIS class B
Sheath material
SUS316 (E52-P@AY)
ASTM316L (E52-P@B-N, E52-P@C-N)
Sheath outer diameter
3.2 dia., 4.8 dia., 6.4 dia., 8 dia
Conductor type
3-conductor system
Temperature range
−196°C to 450°C (in dry air)
4
E52
Exposed-lead Models
E52-P@AY
Dimensions
Marking tube
(Red)
Shrinkable tube
(Black)
Sleeve (SUS304)
Sheath (SUS316)
Swage
Marking tube
(White)
Unit (mm)
Crimping terminal
Y type for M3.5
White
Product Label
d
l
3.2 dia.
8
40
4.8 dia.
8
40
6.4 dia.
8
40
D
Red
Red (A)
Lead wire
Lead Wire
White (B)
D±0.05
8 dia.
Black (B)
(30)
L±3%
40
M±4%
(80)
85±10
• Standard (−20°C to 70°C):
Fully vinyl-covered with twelve 0.18-dia
conductors (0.3 mm thick) and 4.8 mm
in outer dia. The sleeve resists a
temperature range between 0°C and
70°C.
• Heat Resistive (0°C to 180°C):
Fully glass-wool-covered with thirty
0.12-dia. conductors (0.3 mm thick)
externally shielded with stainless steel,
4 mm in outer dia. The sleeve resists a
temperature range between 0°C and
100°C.
• Lead Wire Length (M): 1, 2, 4, or 8 m
Model Information
Custom-made models are available on request. Refer to page 4 for details.
Terminal type
Protective
tubing
diameter D
(mm)
Exposed-lead 3.2 dia.
Models
Protective
tubing length
L (cm)
15
20
35
4.8 dia.
20
35
50
Lead wire
type
20
35
50
2
4
8
Model
Standard
E52-P15AY D=3.2 E52-P15AY D=3.2 E52-P15AY D=3.2 E52-P15AY D=3.2
1M
2M
4M
8M
Heat resistive
E52-P15AY D=3.2 E52-P15AY D=3.2 E52-P15AY D=3.2 E52-P15AY D=3.2
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P20AY D=3.2 E52-P20AY D=3.2 E52-P20AY D=3.2 E52-P20AY D=3.2
1M
2M
4M
8M
Heat resistive
E52-P20AY D=3.2 E52-P20AY D=3.2 E52-P20AY D=3.2 E52-P20AY D=3.2
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P35AY D=3.2 E52-P35AY D=3.2 E52-P35AY D=3.2 E52-P35AY D=3.2
1M
2M
4M
8M
Heat resistive
E52-P35AY D=3.2 E52-P35AY D=3.2 E52-P35AY D=3.2 E52-P35AY D=3.2
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P20AY D=4.8 E52-P20AY D=4.8 E52-P20AY D=4.8 E52-P20AY D=4.8
1M
2M
4M
8M
Heat resistive
E52-P20AY D=4.8 E52-P20AY D=4.8 E52-P20AY D=4.8 E52-P20AY D=4.8
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P35AY D=4.8 E52-P35AY D=4.8 E52-P35AY D=4.8 E52-P35AY D=4.8
1M
2M
4M
8M
Heat resistive
E52-P35AY D=4.8 E52-P35AY D=4.8 E52-P35AY D=4.8 E52-P35AY D=4.8
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P50AY D=4.8
1M
E52-P50AY D=4.8
NETU 1M
Heat resistive
6.4 dia.
Lead wire length M (m)
1
E52-P50AY D=4.8
2M
E52-P50AY D=4.8
NETU 2M
E52-P50AY D=4.8
4M
E52-P50AY D=4.8
NETU 4M
E52-P50AY D=4.8
8M
E52-P50AY D=4.8
NETU 8M
Standard
E52-P20AY D=6.4 E52-P20AY D=6.4 E52-P20AY D=6.4 E52-P20AY D=6.4
1M
2M
4M
8M
Heat resistive
E52-P20AY D=6.4 E52-P20AY D=6.4 E52-P20AY D=6.4 E52-P20AY D=6.4
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P35AY D=6.4 E52-P35AY D=6.4 E52-P35AY D=6.4 E52-P35AY D=6.4
1M
2M
4M
8M
Heat resistive
E52-P35AY D=6.4 E52-P35AY D=6.4 E52-P35AY D=6.4 E52-P35AY D=6.4
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P50AY D=6.4 E52-P50AY D=6.4 E52-P50AY D=6.4 E52-P50AY D=6.4
1M
2M
4M
8M
Heat resistive
E52-P50AY D=6.4 E52-P50AY D=6.4 E52-P50AY D=6.4 E52-P50AY D=6.4
NETU 1M
NETU 2M
NETU 4M
NETU 8M
5
E52
Enclosed-terminal Models
E52-P@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
(66)
Product label
Cap
Socket (SUS304)
Sheath (ASTM316L)
Swage
58 dia.
D±0.05
(66)
Terminal box
(15)
Chain
40
G
3
8
L-35±3%
Use wiring terminals that fit M3 screws.
(Packing internal diameter : 6.5 dia)
Terminal box: The permissible temperature is 0°C to 90°C.
Note: 1. The terminals in the cap indicate polarity (A, B, b).
2. The length L is in centimeters, but “35” is 35 millimeters.
Therefore, for the E52-P35C-N: L = 35 (cm), the sheath length L − 35 = 350 − 35 = 315 mm.
Model Information
Custom-made models are available on request. Refer to page 4 for details.
Terminal type
Protective
tubing length
L (cm)
Enclosed-terminal
Models
Protective tubing diameter D (mm)
3.2 dia.
4.8 dia.
6.4 dia.
8 dia.
Model
20
E52-P20C-N D=3.2
E52-P20C-N D=4.8
E52-P20C-N D=6.4
E52-P20C-N D=8
35
E52-P35C-N D=3.2
E52-P35C-N D=4.8
E52-P35C-N D=6.4
E52-P35C-N D=8
50
E52-P50C-N D=3.2
E52-P50C-N D=4.8
E52-P50C-N D=6.4
E52-P50C-N D=8
75
---
E52-P75C-N D=4.8
E52-P75C-N D=6.4
---
Exposed-terminal Models
E52-P@B-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Model Information
Terminal box
Socket (SUS304)
5.6
Product label
Swage
b
B
A
Sheath (ASTM316L)
8±0.05 dia.
Custom-made models are available on request. Refer to page 4 for
details
Terminal
type
19.2
45
17
17.6
19 dia.
21.5
3×M3
30.5
42.5
(51)
(15)
L-40±3%
Terminal box: The permissible temperature is 0°C to 100°C.
Exposedterminal
Models
Protective Protective tubing diameter D (mm)
tubing length
8 dia.
L (cm)
Model
20
E52-P20B-N D=8
35
E52-P35B-N D=8
50
E52-P50B-N D=8
Note: The length L is in centimeters, but “40” is 40 millimeters.
Therefore, for the E52-P35B-N: L = 35 (cm), the sheath length L − 40 = 350 − 40 = 310 mm.
6
E52
■ Standard Platinum Resistance Thermometers
Refer to Model Number Legend on page 4 for the Pt100.
Specifications
Element type
Pt100
Class
JIS class B
Protective tubing material
SUS316
Conductor type
3-conductor system
Temperature range
0°C to 450°C (in dry air)
Note: 1. Use the sheathed platinum resistance thermometer if condensation is likely to result.
Enclosed-terminal Models
E52-P@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
(92)
Product label
Cap
Socket (SUS304)
Full-circled Welding
82 dia.
Protective tubing (SUS316)
10±0.3 dia.
(86)
38 dia.
Chain
G1 2
(Packing internal
diameter : 9 dia.)
Terminal
box
(5)
L-50±3%
53
Note: 1. The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-P75C-N: L = 75 (cm), the protective tubing length L − 50 = 750 − 50 = 700 mm.
Terminal box: The permissible temperature is 0°C to 90°C.
Note: The terminals in the cap indicate polarity (A, B, B).
Model Information
Custom-made models are available on request. Refer to page 4 for details.
Terminal type
Protective tubing
length L (cm)
Protective tubing
diameter D (mm)
10 dia.
Model
Enclosed-terminal
Models
35
E52-P35C-N D=10
50
E52-P50C-N D=10
75
E52-P75C-N D=10
100
E52-P100C-N D=10
7
E52
■ Model Number Legend
The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below.
Thermocouples
E52-@@@ D=@@@M@
1 2 3
4
5 6
7
1. Element type
CA:K
IC: J
PR:R
2. Protective tubing length (L)
Specify the length in centimeters in the following range: Unit (cm)
4. Diameter
Specify the protective tubing material according to the table.
Code
Diameter Protective tubing
(D)
construction
Protective tubing
material
1
1 mm
Sheathed
ASTM316L
1.6
1.6 mm
Sheathed
ASTM316L
E52-@@AY (Exposed-lead Model)
3.2
3.2 mm
Sheathed
ASTM316L
Diameter (D)
4.8
4.8 mm
Sheathed
ASTM316L
6.4
6.4 mm
Sheathed
ASTM316L
8
8 mm
Sheathed
ASTM316L
10
10 mm
Standard
SUS316, SUS310S
12
12 mm
Standard
SUS316, SUS310S
15
15 mm
Standard
Length (L)
1
2 to 200
1.6
3 to 500
3.2
5 to 2,000
4.8
8 to 2,300
6.4
10 to 1,200
8
12 to 1,000
E52-@@B-N and E52-@@C-N (except E52-PR@C-N)
Diameter (D)
Length (L)
3.2
11 to 2,000
4.8
14 to 2,300
6.4
16 to 1,200
8.0
18 to 1,000
10
21 to 126
12
24 to 126
15
29 to 156
22
39 to 206
E52-PR@C-N
Diameter (D)
15
SUS316, SUS310S
PT1, PT0 (E52-PR)
22
22 mm
Standard
SUS316, SUS310S
5. Heat resistance
Specify this item for the exposed-lead models only.
Code
Temperature range
Lead type
---
−20°C to 70°C
Sleeve: 0°C to 70°C
Vinyl-covered
NETU
0°C to 150°C
Sleeve: 0°C to 100°C
Glass-wool-covered with external shield of stainless
6. Lead length (M)
Specify the length in meters in the following range for the E52@@AY only.
Range: 1 to 100 m
7. Protective tubing material
Length (L)
Code
50, 75, 100
3. Terminal
AY: Exposed lead wires (Y-type crimp terminal for M3.5)
(element type: K, J)
B-N: Exposed terminals (element type: K, J)
C-N: Enclosed terminals (element type: K, J, R)
Protective tubing
material
Element type
---
ASTM316L
K, J
SUS310S
SUS310S
K, D = 10 to 22
PT1
JIS ceramic Cat.1
R
PT0
JIS special ceramic
R
Examples
Element: K; protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m
E52-CA42AY D=4.8 NETU 10M
Element: J; protective tubing length: 360 mm, enclosed terminals, protective tubing dia.: 3.2
E52-IC36C-N D=3.2
8
E52
■ Sheathed Thermocouples
Specifications
Permissible Temperature in Dry Air
D
Element type
K (CA), J(IC)
Class
JIS class 2 (0.75)
Thermal contact
Non-grounded type
Sheath material
CA: ASTM316L
Element wire
K (CA)
ASTM316L
IC: ASTM316L
J (IC)
ASTM316L
1 dia.
650°C
450°C
1.6 dia.
650°C
450°C
3.2 dia.
750°C
650°C
4.8 dia.
800°C
750°C
6.4 dia.
800°C
750°C
8.0 dia.
900°C
750°C
Note: For details on the permissible temperature, refer to page D-5 of
Introduction of Temperature Controllers (Cat. No. H900).
Exposed-lead Models
E52-CA@AY
Dimensions
Sleeve (SUS304)
Sheath (ASTM316L)
Swage
Lead
wire
Unit (mm)
Crimping terminal
Y type for M3.5
Shrinkable tube
(CA:Blue, IC:Yellow)
Red (+)
Product label
D±0.05
30±5
M±4%
55
l
8
55
1.6 dia.
8
55
3.2 dia.
8
55
4.8 dia.
8
55
6.4 dia.
11
55
8 dia.
11
55
D
d
L±3%
d
1 dia.
Transparent
Marking tube (White)
(80)
90±10
White (−)
Note: 1. Lead Wire (Compensating Conductor)
• Standard (−20°C to 70°C):
Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm
thick) and external dimensions of 2.4 × 4.1.
• Heat Resistive (0°C to 150°C):
Fully glass-wool-covered with seven 0.3-dia. conductors
(0.5 mm thick) with external shield of stainless steel and
external dimensions of 2.8 × 4.6
The heat-resistive lead wires cannot be used in locations
exposed to water or other liquids.
• Lead Wire Length (M): 1, 2, 4, or 8 m
2. The sleeve resists temperatures ranging between −20°C and
70°C for standard models and 0°C and 100°C for heat-resistive
models.
Permissible Temperature in Dry Air
D
Element wire
K (CA)
ASTM316L
1 dia.
650°C
1.6 dia.
650°C
3.2 dia.
750°C
4.8 dia.
800°C
6.4 dia.
800°C
8.0 dia.
900°C
K (CA) Model Information (E52-CA@AY)
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.
Terminal type
Protective
Protective
tubing diameter tubing length L
D (mm)
(cm)
Lead wire type
Lead wire length M (m)
1
2
4
8
Model
Exposed-lead
Models
1 dia.
15
20
35
Standard
E52-CA15AY D=1
1M
E52-CA15AY D=1
2M
E52-CA15AY D=1
4M
E52-CA15AY D=1
8M
Heat resistive
E52-CA15AY D=1
NETU 1M
E52-CA15AY D=1
NETU 2M
E52-CA15AY D=1
NETU 4M
E52-CA15AY D=1
NETU 8M
Standard
E52-CA20AY D=1
1M
E52-CA20AY D=1
2M
E52-CA20AY D=1
4M
E52-CA20AY D=1
8M
Heat resistive
E52-CA20AY D=1
NETU 1M
E52-CA20AY D=1
NETU 2M
E52-CA20AY D=1
NETU 4M
E52-CA20AY D=1
NETU 8M
Standard
E52-CA35AY D=1
1M
E52-CA35AY D=1
2M
E52-CA35AY D=1
4M
E52-CA35AY D=1
8M
Heat resistive
E52-CA35AY D=1
NETU 1M
E52-CA35AY D=1
NETU 2M
E52-CA35AY D=1
NETU 4M
E52-CA35AY D=1
NETU 8M
9
E52
Terminal type
Protective
Protective
tubing diameter tubing length L
D (mm)
(cm)
Lead wire type
Lead wire length M (m)
1
2
4
8
Model
Exposed-lead
Models
1.6 dia.
15
20
35
3.2 dia.
15
20
35
50
4.8 dia.
20
35
50
6.4 dia.
20
35
50
8 dia.
20
35
50
Standard
E52-CA15AY D=1.6
1M
E52-CA15AY D=1.6
2M
E52-CA15AY D=1.6
4M
E52-CA15AY D=1.6
8M
Heat resistive
E52-CA15AY D=1.6
NETU 1M
E52-CA15AY D=1.6
NETU 2M
E52-CA15AY D=1.6
NETU 4M
E52-CA15AY D=1.6
NETU 8M
Standard
E52-CA20AY D=1.6
1M
E52-CA20AY D=1.6
2M
E52-CA20AY D=1.6
4M
E52-CA20AY D=1.6
8M
Heat resistive
E52-CA20AY D=1.6
NETU 1M
E52-CA20AY D=1.6
NETU 2M
E52-CA20AY D=1.6
NETU 4M
E52-CA20AY D=1.6
NETU 8M
Standard
E52-CA35AY D=1.6
1M
E52-CA35AY D=1.6
2M
E52-CA35AY D=1.6
4M
E52-CA35AY D=1.6
8M
Heat resistive
E52-CA35AY D=1.6
NETU 1M
E52-CA35AY D=1.6
NETU 2M
E52-CA35AY D=1.6
NETU 4M
E52-CA35AY D=1.6
NETU 8M
Standard
E52-CA15AY D=3.2
1M
E52-CA15AY D=3.2
2M
E52-CA15AY D=3.2
4M
E52-CA15AY D=3.2
8M
Heat resistive
E52-CA15AY D=3.2
NETU 1M
E52-CA15AY D=3.2
NETU 2M
E52-CA15AY D=3.2
NETU 4M
E52-CA15AY D=3.2
NETU 8M
Standard
E52-CA20AY D=3.2
1M
E52-CA20AY D=3.2
2M
E52-CA20AY D=3.2
4M
E52-CA20AY D=3.2
8M
Heat resistive
E52-CA20AY D=3.2
NETU 1M
E52-CA20AY D=3.2
NETU 2M
E52-CA20AY D=3.2
NETU 4M
E52-CA20AY D=3.2
NETU 8M
Standard
E52-CA35AY D=3.2
1M
E52-CA35AY D=3.2
2M
E52-CA35AY D=3.2
4M
E52-CA35AY D=3.2
8M
Heat resistive
E52-CA35AY D=3.2
NETU 1M
E52-CA35AY D=3.2
NETU 2M
E52-CA35AY D=3.2
NETU 4M
E52-CA35AY D=3.2
NETU 8M
Standard
E52-CA50AY D=3.2
1M
E52-CA50AY D=3.2
2M
E52-CA50AY D=3.2
4M
E52-CA50AY D=3.2
8M
Heat resistive
E52-CA50AY D=3.2
NETU 1M
E52-CA50AY D=3.2
NETU 2M
E52-CA50AY D=3.2
NETU 4M
E52-CA50AY D=3.2
NETU 8M
Standard
E52-CA20AY D=4.8
1M
E52-CA20AY D=4.8
2M
E52-CA20AY D=4.8
4M
E52-CA20AY D=4.8
8M
Heat resistive
E52-CA20AY D=4.8
NETU 1M
E52-CA20AY D=4.8
NETU 2M
E52-CA20AY D=4.8
NETU 4M
E52-CA20AY D=4.8
NETU 8M
Standard
E52-CA35AY D=4.8
1M
E52-CA35AY D=4.8
2M
E52-CA35AY D=4.8
4M
E52-CA35AY D=4.8
8M
Heat resistive
E52-CA35AY D=4.8
NETU 1M
E52-CA35AY D=4.8
NETU 2M
E52-CA35AY D=4.8
NETU 4M
E52-CA35AY D=4.8
NETU 8M
Standard
E52-CA50AY D=4.8
1M
E52-CA50AY D=4.8
2M
E52-CA50AY D=4.8
4M
E52-CA50AY D=4.8
8M
Heat resistive
E52-CA50AY D=4.8
NETU 1M
E52-CA50AY D=4.8
NETU 2M
E52-CA50AY D=4.8
NETU 4M
E52-CA50AY D=4.8
NETU 8M
Standard
E52-CA20AY D=6.4
1M
E52-CA20AY D=6.4
2M
E52-CA20AY D=6.4
4M
E52-CA20AY D=6.4
8M
Heat resistive
E52-CA20AY D=6.4
NETU 1M
E52-CA20AY D=6.4
NETU 2M
E52-CA20AY D=6.4
NETU 4M
E52-CA20AY D=6.4
NETU 8M
Standard
E52-CA35AY D=6.4
1M
E52-CA35AY D=6.4
2M
E52-CA35AY D=6.4
4M
E52-CA35AY D=6.4
8M
Heat resistive
E52-CA35AY D=6.4
NETU 1M
E52-CA35AY D=6.4
NETU 2M
E52-CA35AY D=6.4
NETU 4M
E52-CA35AY D=6.4
NETU 8M
Standard
E52-CA50AY D=6.4
1M
E52-CA50AY D=6.4
2M
E52-CA50AY D=6.4
4M
E52-CA50AY D=6.4
8M
Heat resistive
E52-CA50AY D=6.4
NETU 1M
E52-CA50AY D=6.4
NETU 2M
E52-CA50AY D=6.4
NETU 4M
E52-CA50AY D=6.4
NETU 8M
Standard
E52-CA20AY D=8
1M
E52-CA20AY D=8
2M
E52-CA20AY D=8
4M
E52-CA20AY D=8
8M
Heat resistive
E52-CA20AY D=8
NETU 1M
E52-CA20AY D=8
NETU 2M
E52-CA20AY D=8
NETU 4M
E52-CA20AY D=8
NETU 8M
Standard
E52-CA35AY D=8
1M
E52-CA35AY D=8
2M
E52-CA35AY D=8
4M
E52-CA35AY D=8
8M
Heat resistive
E52-CA35AY D=8
NETU 1M
E52-CA35AY D=8
NETU 2M
E52-CA35AY D=8
NETU 4M
E52-CA35AY D=8
NETU 8M
Standard
E52-CA50AY D=8
1M
E52-CA50AY D=8
2M
E52-CA50AY D=8
4M
E52-CA50AY D=8
8M
Heat resistive
E52-CA50AY D=8
NETU 1M
E52-CA50AY D=8
NETU 2M
E52-CA50AY D=8
NETU 4M
E52-CA50AY D=8
NETU 8M
10
E52
Exposed-lead Models
E52-IC@AY
Dimensions
Sleeve (SUS304)
Sheath (ASTM316L)
Product label
Swage
Red (+)
d
30±5
L±3%
55
M±4%
Unit (mm)
(80)
90±10
White (−)
Note: 1. Lead Wire (Compensating Conductor)
• Standard (−20°C to 70°C):
Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm
thick) and external dimensions of 2.4 × 4.1.
• Heat Resistive (0°C to 150°C):
Fully glass-wool-covered with seven 0.3-dia. conductors
(0.5 mm thick) with external shield of stainless steel and
external dimensions of 2.8 × 4.6
The heat-resistive lead wires cannot be used in locations
exposed to water or other liquids.
• Lead Wire Length (M): 1, 2, 4, or 8 m
2. The sleeve resists temperatures ranging between −20°C and
70°C for standard models and 0°C and 100°C for heat-resistive
models.
Permissible Temperature in Dry Air
d
l
1 dia.
8
55
1.6 dia.
8
55
3.2 dia.
8
55
4.8 dia.
8
55
6.4 dia.
11
55
8 dia.
11
55
D
Transparent
Marking tube (White)
Lead wire
D±0.05
Crimping terminal
Y type for M3.5
Shrinkable tube
(CA:Blue, IC:Yellow)
D
Element wire
J (IC)
ASTM316L
1 dia.
450°C
1.6 dia.
450°C
3.2 dia.
650°C
4.8 dia.
750°C
6.4 dia.
750°C
8.0 dia.
750°C
J (IC) Model Information (E52-IC@AY)
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details
Terminal type
Protective
tubing
diameter D
(mm)
Exposed-lead 1 dia.
Models
Protective
tubing length
L (cm)
15
20
35
1.6 dia.
15
20
35
Lead wire
type
Lead wire length M (m)
1
2
4
Model
Standard
E52-IC15AY D=1 1M
E52-IC15AY D=1 2M
E52-IC15AY D=1 4M
Heat resistive
E52-IC15AY D=1 NETU
1M
E52-IC15AY D=1 NETU
2M
E52-IC15AY D=1 NETU
4M
Standard
E52-IC20AY D=1 1M
E52-IC20AY D=1 2M
E52-IC20AY D=1 4M
Heat resistive
E52-IC20AY D=1 NETU
1M
E52-IC20AY D=1 NETU
2M
E52-IC20AY D=1 NETU
4M
Standard
E52-IC35AY D=1 1M
E52-IC35AY D=1 2M
E52-IC35AY D=1 4M
Heat resistive
E52-IC35AY D=1 NETU
1M
E52-IC35AY D=1 NETU
2M
E52-IC35AY D=1 NETU
4M
Standard
E52-IC15AY D=1.6 1M
E52-IC15AY D=1.6 2M
E52-IC15AY D=1.6 4M
Heat resistive
E52-IC15AY D=1.6
NETU 1M
E52-IC15AY D=1.6
NETU 2M
E52-IC15AY D=1.6
NETU 4M
Standard
E52-IC20AY D=1.6 1M
E52-IC20AY D=1.6 2M
E52-IC20AY D=1.6 4M
Heat resistive
E52-IC20AY D=1.6
NETU 1M
E52-IC20AY D=1.6
NETU 2M
E52-IC20AY D=1.6
NETU 4M
Standard
E52-IC35AY D=1.6 1M
E52-IC35AY D=1.6 2M
E52-IC35AY D=1.6 4M
Heat resistive
E52-IC35AY D=1.6
NETU 1M
E52-IC35AY D=1.6
NETU 2M
E52-IC35AY D=1.6
NETU 4M
11
E52
Terminal type
Protective
tubing
diameter D
(mm)
Exposed-lead 3.2 dia.
Models
Protective
tubing length
L (cm)
15
20
35
50
4.8 dia.
20
35
50
6.4 dia.
20
35
50
8 dia.
20
35
50
Lead wire
type
1
Lead wire length M (m)
2
4
Model
Standard
E52-IC15AY D=3.2 1M
E52-IC15AY D=3.2 2M
E52-IC15AY D=3.2 4M
Heat resistive
E52-IC15AY D=3.2
NETU 1M
E52-IC15AY D=3.2
NETU 2M
E52-IC15AY D=3.2
NETU 4M
Standard
E52-IC20AY D=3.2 1M
E52-IC20AY D=3.2 2M
E52-IC20AY D=3.2 4M
Heat resistive
E52-IC20AY D=3.2
NETU 1M
E52-IC20AY D=3.2
NETU 2M
E52-IC20AY D=3.2
NETU 4M
Standard
E52-IC35AY D=3.2 1M
E52-IC35AY D=3.2 2M
E52-IC35AY D=3.2 4M
Heat resistive
E52-IC35AY D=3.2
NETU 1M
E52-IC35AY D=3.2
NETU 2M
E52-IC35AY D=3.2
NETU 4M
Standard
E52-IC50AY D=3.2 1M
E52-IC50AY D=3.2 2M
E52-IC50AY D=3.2 4M
Heat resistive
E52-IC50AY D=3.2
NETU 1M
E52-IC50AY D=3.2
NETU 2M
E52-IC50AY D=3.2
NETU 4M
Standard
E52-IC20AY D=4.8 1M
E52-IC20AY D=4.8 2M
E52-IC20AY D=4.8 4M
Heat resistive
E52-IC20AY D=4.8
NETU 1M
E52-IC20AY D=4.8
NETU 2M
E52-IC20AY D=4.8
NETU 4M
Standard
E52-IC35AY D=4.8 1M
E52-IC35AY D=4.8 2M
E52-IC35AY D=4.8 4M
Heat resistive
E52-IC35AY D=4.8
NETU 1M
E52-IC35AY D=4.8
NETU 2M
E52-IC35AY D=4.8
NETU 4M
Standard
E52-IC50AY D=4.8 1M
E52-IC50AY D=4.8 2M
E52-IC50AY D=4.8 4M
Heat resistive
E52-IC50AY D=4.8
NETU 1M
E52-IC50AY D=4.8
NETU 2M
E52-IC50AY D=4.8
NETU 4M
Standard
E52-IC20AY D=6.4 1M
E52-IC20AY D=6.4 2M
E52-IC20AY D=6.4 4M
Heat resistive
E52-IC20AY D=6.4
NETU 1M
E52-IC20AY D=6.4
NETU 2M
E52-IC20AY D=6.4
NETU 4M
Standard
E52-IC35AY D=6.4 1M
E52-IC35AY D=6.4 2M
E52-IC35AY D=6.4 4M
Heat resistive
E52-IC35AY D=6.4
NETU 1M
E52-IC35AY D=6.4
NETU 2M
E52-IC35AY D=6.4
NETU 4M
Standard
E52-IC50AY D=6.4 1M
E52-IC50AY D=6.4 2M
E52-IC50AY D=6.4 4M
Heat resistive
E52-IC50AY D=6.4
NETU 1M
E52-IC50AY D=6.4
NETU 2M
E52-IC50AY D=6.4
NETU 4M
Standard
E52-IC20AY D=8 1M
E52-IC20AY D=8 2M
E52-IC20AY D=8 4M
Heat resistive
E52-IC20AY D=8 NETU
1M
E52-IC20AY D=8 NETU
2M
E52-IC20AY D=8 NETU
4M
Standard
E52-IC35AY D=8 1M
E52-IC35AY D=8 2M
E52-IC35AY D=8 4M
Heat resistive
E52-IC35AY D=8 NETU
1M
E52-IC35AY D=8 NETU
2M
E52-IC35AY D=8 NETU
4M
Standard
E52-IC50AY D=8 1M
E52-IC50AY D=8 2M
E52-IC50AY D=8 4M
Heat resistive
E52-IC50AY D=8 NETU
1M
E52-IC50AY D=8 NETU
2M
E52-IC50AY D=8 NETU
4M
12
E52
Exposed-terminal Models
E52-CA@B-N
E52-IC@B-N
Dimensions
Permissible Temperature in Dry Air
Dimensions are given in millimeters, except for the length (L), which
is provided in centimeters.
D
Element wire
K (CA)
ASTM316L
Product label
Terminal box
2×10 dia.
Socket (SUS304)
Swage
+
Sheath (ASTM316L)
D±0.05
44 18
−
4
2×M3
16
8
3.2 dia.
750°C
650°C
4.8 dia.
800°C
750°C
6.4 dia.
800°C
750°C
8.0 dia.
900°C
750°C
Terminal box: The permissible temperature is 0°C to 100°C.
3.5
(15)
38.5
(52)
22 dia.
J (IC)
ASTM316L
L-40±3%
Note: The length L is in centimeters, but “40” is 40 millimeters.
Therefore, for the E52-CA50B-N: L = 50 (cm), the sheath length L − 40 = 500 − 40 = 460 mm.
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.
Element type Terminal type
K (CA)
Exposed-terminal Models
J (IC)
Exposed-terminal Models
Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
3.2 dia.
4.8 dia.
6.4 dia.
8 dia.
Model
20
E52-CA20B-N D=3.2
E52-CA20B-N D=4.8
E52-CA20B-N D=6.4
---
35
E52-CA35B-N D=3.2
E52-CA35B-N D=4.8
E52-CA35B-N D=6.4
E52-CA35B-N D=8
50
E52-CA50B-N D=3.2
E52-CA50B-N D=4.8
E52-CA50B-N D=6.4
E52-CA50B-N D=8
75
---
E52-CA75B-N D=4.8
E52-CA75B-N D=6.4
E52-CA75B-N D=8
20
E52-IC20B-N D=3.2
E52-IC20B-N D=4.8
E52-IC20B-N D=6.4
---
35
E52-IC35B-N D=3.2
E52-IC35B-N D=4.8
E52-IC35B-N D=6.4
E52-IC35B-N D=8
50
E52-IC50B-N D=3.2
E52-IC50B-N D=4.8
E52-IC50B-N D=6.4
E52-IC50B-N D=8
75
---
E52-IC75B-N D=4.8
E52-IC75B-N D=6.4
E52-IC75B-N D=8
Enclosed-terminal Models
E52-CA@C-N
E52-IC@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which
is provided in centimeters.
(66)
Permissible Temperature in Dry Air
D
Element wire
Product label
K (CA)
ASTM316L
Cap
Socket (SUS304)
Swage
58 dia.
Sheath (ASTM316L)
D±0.05
(66)
(15)
Chain
Terminal box
3.2 dia.
750°C
650°C
4.8 dia.
800°C
750°C
6.4 dia.
800°C
750°C
8.0 dia.
900°C
750°C
Terminal box: The permissible temperature is 0°C to 90°C.
L-40±3%
40
G3 8
(Packing internal diameter 6.5 dia.)
J (IC)
ASTM316L
Use wiring terminals that fit M3 screws.
Note: The terminals in the cap indicate polarity (+ or −).
Note: The length L is in centimeters, but “40” is 40 millimeters.
Therefore, for the E52-CA35C-N: L = 35 (cm), the sheath length L − 40 = 350 − 40 = 310 mm.
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.
Element type Terminal type
K (CA)
J (IC)
Enclosed-terminal Models
Enclosed-terminal Models
Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
3.2 dia.
4.8 dia.
6.4 dia.
8 dia.
Model
20
E52-CA20C-N D=3.2
E52-CA20C-N D=4.8
E52-CA20C-N D=6.4
---
35
E52-CA35C-N D=3.2
E52-CA35C-N D=4.8
E52-CA35C-N D=6.4
E52-CA35C-N D=8
50
E52-CA50C-N D=3.2
E52-CA50C-N D=4.8
E52-CA50C-N D=6.4
E52-CA50C-N D=8
75
---
E52-CA75C-N D=4.8
E52-CA75C-N D=6.4
E52-CA75C-N D=8
20
E52-IC20C-N D=3.2
E52-IC20C-N D=4.8
E52-IC20C-N D=6.4
---
35
E52-IC35C-N D=3.2
E52-IC35C-N D=4.8
E52-IC35C-N D=6.4
E52-IC35C-N D=8
50
E52-IC50C-N D=3.2
E52-IC50C-N D=4.8
E52-IC50C-N D=6.4
E52-IC50C-N D=8
75
---
E52-IC75C-N D=4.8
E52-IC75C-N D=6.4
E52-IC75C-N D=8
13
E52
■ Standard Thermocouples
Specifications
Permissible Temperature in Dry Air (See note.)
D
Element wire
K (CA), J(IC), R(PR)
Class
K (CA), J (IC) JIS class 2 (0.75)
Protective tubing material
J (IC) SUS316
R(PR), JIS class 2 (0.25)
10 dia.
750°C
450°C
K (CA) SUS316
12 dia.
850°C
500°C
J (IC)
15 dia.
900°C
550°C
22 dia.
900°C
600°C
SUS316
R (See JIS ceramic cat. 1 (PT1)
note.) JIS special ceramic (PT0)
Thermal contact
Element wire
K (CA) SUS316
Note: For details on the permissible temperature, refer to Technical
Guide for Temperature Sensors.
Non-grounded type
Note: Specify PT1 or PT0 if the element is R.
D
Element wire
R
15 dia.
0°C to 1,400°C
Exposed-terminal Models
E52-CA@B-N
E52-IC@B-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
25.5
9.6
25
Product label
Terminal box
2×12 dia.
Socket (SUS304)
18
Protective tubing (SUS316 or SUS310S)
−
70
30.8
+
3.8
18
D
Full-circled welding
2×M4
30 dia.
34.5
5
8
(5)
8
49.5
L-50±3%
(65.5)
Terminal box: The permissible temperature is 0°C to 100°C.
Note: The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-CA75B-N: L = 75 (cm), the protective tubing length L − 50 = 750 − 50 = 700 mm.
Permissible Temperature in Dry Air
D
Element wire
K (CA) SUS316
J (IC) SUS316
10 dia.
750°C
450°C
12 dia.
850°C
500°C
15 dia.
850°C
550°C
22 dia.
900°C
600°C
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.
Element type Terminal type
K (CA)
J (IC)
Exposed-terminal Models
Exposed-terminal Models
Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
10 dia.
12 dia.
15 dia.
22 dia.
Model
35
E52-CA35B-N D=10
E52-CA35B-N D=12
E52-CA35B-N D=15
---
50
E52-CA50B-N D=10
E52-CA50B-N D=12
E52-CA50B-N D=15
E52-CA50B-N D=22
75
E52-CA75B-N D=10
E52-CA75B-N D=12
E52-CA75B-N D=15
E52-CA75B-N D=22
100
E52-CA100B-N D=10
E52-CA100B-N D=12
E52-CA100B-N D=15
E52-CA100B-N D=22
35
E52-IC35B-N D=10
E52-IC35B-N D=12
E52-IC35B-N D=15
---
50
E52-IC50B-N D=10
E52-IC50B-N D=12
E52-IC50B-N D=15
E52-IC50B-N D=22
75
E52-IC75B-N D=10
E52-IC75B-N D=12
E52-IC75B-N D=15
E52-IC75B-N D=22
100
E52-IC100B-N D=10
E52-IC100B-N D=12
E52-IC100B-N D=15
E52-IC100B-N D=22
14
E52
Enclosed-terminal Models
E52-CA@C-N
E52-IC@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
(92)
Cap
Product
label
82 dia.
Socket (SUS304)
Full-circled Welding
Protective tubing (SUS316 or SUS310S)
D
(86)
38 dia.
Terminal
box
(5)
Chain
G1 2
L-50±3%
53
(Packing internal diameter : 9 dia.)
Note: The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-CA50C-N: L = 50 (cm), the protective tubing length L − 50 = 500 − 50 = 450 mm.
Permissible Temperature in Dry Air
D
Element wire
K (CA) SUS316
J (IC) SUS316
10 dia.
0 to 750°C
0 to 450°C
12 dia.
0 to 850°C
0 to 500°C
15 dia.
0 to 850°C
0 to 550°C
22 dia.
0 to 900°C
0 to 600°C
Terminal box: The permissible temperature is 0°C to 90°C.
Note: The terminals in the cap indicate polarity (+ or −).
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details
Element type Terminal type
K (CA)
J (IC)
Enclosed-terminal Models
Enclosed-terminal Models
Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
10 dia.
12 dia.
15 dia.
22 dia.
Model
35
E52-CA35C-N D=10
E52-CA35C-N D=12
E52-CA35C-N D=15
---
50
E52-CA50C-N D=10
E52-CA50C-N D=12
E52-CA50C-N D=15
E52-CA50C-N D=22
75
E52-CA75C-N D=10
E52-CA75C-N D=12
E52-CA75C-N D=15
E52-CA75C-N D=22
100
E52-CA100C-N D=10
E52-CA100C-N D=12
E52-CA100C-N D=15 E52-CA100C-N D=22
35
E52-IC35C-N D=10
E52-IC35C-N D=12
E52-IC35C-N D=15
50
E52-IC50C-N D=10
E52-IC50C-N D=12
E52-IC50C-N D=15
E52-IC50C-N D=22
75
E52-IC75C-N D=10
E52-IC75C-N D=12
E52-IC75C-N D=15
---
100
E52-IC100C-N D=10
E52-IC100C-N D=12
E52-IC100C-N D=15
---
---
15
E52
Enclosed-terminal Models (High-temperature Use)
E52-PR@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
(92)
Cap
Product label
Support (SUS304)
82 dia.
Ceramic protective tubing (PT0 or PT1)
15±0.7 dia.
(86)
*
21.7 dia.
38 dia.
Chain
* Tubing distortion
A dimensions more than 500mm:
0.6% or less
A dimensions are less than 500mm:
3mm or less
Terminal
box
(5)
G1 2
(100)
(Packing internal diameter : 9 dia.)
L-150±3%
A
53
Use wiring terminals that fit M4 screws.
Permissible Temperature in Dry Air
D
Element wire
R
15 dia. 0°C to 1,400°C
Terminal box: The permissible temperature is 0°C to 90°C.
Note: The terminals in the cap indicate polarity (+ or −).
Note: The length L is in centimeters, but “150” is 150 millimeters.
Therefore, for the E52-PR75C-N: L = 75 (cm), the protective tubing length L − 150 = 750 − 150 = 600 mm.
Model Information
Element
type
R (See
note 1.)
Terminal
type
Protective
tubing
length L
(cm)
Enclosed-ter- 50
minal Models 75
100
R (See
note 2.)
Enclosed-ter- 50
minal Models 75
100
Standard
Protective tubing
diameter D (mm)
15 dia.
Model
E52-PR50C-N D=15 PT1
E52-PR75C-N D=15 PT1
E52-PR100C-N D=15 PT1
E52-PR50C-N D=15 PT0
E52-PR75C-N D=15 PT0
E52-PR100C-N D=15 PT0
Protective tubing
material
Permissible
temperature in dry
air
Note 1:
JIS ceramic Cat.1
(PT1)
Mullite, high
alumina, etc.
1,500°C (See note.)
Note 2:
JIS special ceramic
(PT0)
Recrystallized
alumina, fused
alumina, etc.
1,600°C (See note.)
Note: The permissible temperature given for the protective tubing is higher than 1,400°C, but the permissible temperature of the thermocouple
element wire is only 1,400°C. Therefore, the protective tubing of the E52-PR@C-N can withstand high temperatures momentarily to the
levels given in the table as exceptions, but the element wire will deteriorate quickly if the thermocouple is used regularly at temperatures
that exceed the permissible temperature for the element wire.
16
E52
Low-cost Models
■ Low-cost Platinum Resistance Thermometers
Exposed-lead Models with Screws
Specifications
E52-P6DY
Element type
Pt100
Dimensions
Conductor type
3-conductor system
Class
Class B
Protective tubing
material
SUS304
Sensor length
30 mm
Max. detectable
temperature
250°C
Temperature
range
−50°C to 250°C
Lead wire
Fluororesin-covered
wire (PFA) with 1.0
outer dia.
7/0.18
−50°C to 150°C
Taper screw for tube R1/8 (SUS304)
Full-circled welding
(16)
Crimping terminal Y type for M3.5
Siliconized shrinkable tube
Protective tubing
(SUS304)
Red
Marking tube (Red)
Red (A)
Lead wire
Black (B)
4±0.4 dia.
White (B)
Product label
6±0.5
10±0.5
Marking tube (White) White
(M-16)
(30)
14
65
15
0
-2
M±5%
Note: The protective tubing is of pipe construction, which must not be bent.
Lead wire length (m)
Model
1
E52-P6DY 1M
2
E52-P6DY 2M
4
E52-P6DY 4M
Exposed-lead Models with Flange
Specifications
E52-P6FY
Element wire
Pt100
Dimensions
Conductor type
3-conductor system
Class
Class B
Protective tubing
material
SUS304
Sensor length
30 mm
Max. detectable
temperature
250°C
Temperature
range
−50°C to 250°C
Lead wire
Fluororesin-covered
wire (PFA) with 1.0
outer dia.
7/0.18
−50°C to 150°C
Crimping terminal Y type for M3.5
Nickel brazing
3×3.5 dia.
120°
Red
Siliconized shrinkable tube
Marking tube (Red)
Lead wire
Flange (SUS304)
120° 4±0.4 dia.
Protective tubing
(SUS304)
Red (A)
Black (B)
White (B)
Product label
Marking tube (White)
1
20 dia.
65
30 dia.
15
0
-2
White
(M-16)
M±5%
(30)
Note: The protective tubing is of pipe construction, which must not be bent.
Lead wire length (m)
Model
1
E52-P6FY 1M
2
E52-P6FY 2M
4
E52-P6FY 4M
Exposed-lead Models
Specifications
E52-P10AEY
Element type
Pt100
Dimensions
Conductor type
3-conductor system
Class
Class B
Crimping terminal Y type for M3.5
Product label
Transparent
Marking tube
(White)
Siliconized shrinkable tube
Shrinkable tube (Black)
Red (A)
Protective tubing
material
SUS316
Max. detectable
temperature
250°C
White (B)
Temperature
range
0°C to 250°C
White (B)
Lead wire
Fluororesin-covered
wire (PFA) with 1.0
outer dia.
7/0.18
−50°C to 150°C
3.2±0.05 dia.
Protective tubing (SUS316)
Lead wire
30
30±5
80±10
M±4%
100±3%
Note: 1. The protective tubing is of pipe construction, which must not be bent.
2. A Compression Fitting (PT@) cannot be used for mounting.
Lead wire length (m)
Model
1
E52-P10AEY 1M
2
E52-P10AEY 2M
4
E52-P10AEY 4M
17
E52
■ Low-cost Thermocouples
Exposed-lead Models with Spring
E52-CA@ASY, E52-IC@ASY
Specifications
Dimensions
Element type
K (CA), J (IC)
Element dia.
0.65 mm (single wire)
Class
Class 2 (0.75)
Protective tubing
(SUS304)
Protective tubing
material
SUS304
Thermal contact
Non-grounded type
Temperature range
0°C to 400°C: K (CA)
0°C to 350°C: J (IC)
Lead wire
100°
+0.02
4.8 0 dia.
+0.2
14.5 -0.1 dia.
Sleeve
(Brass nickel chrome
plating)
12±0.05 dia.
Shrinkable tube
(CA:Blue, IC:Yellow)
Protective spring
(SUS304)
Lead wire
11±0.2 dia.
8.2±0.1 dia.
Crimping terminal
Y type for M3.5
Marking tube
(White)
Red (+)
+
−
5±0.5
6.3±1
18±1
L±3
Fully glass-wool-covered
compensating cable and external
dimensions of approx. 5.1 x 3.0
4/0.65
0°C to 180°C
1.2±0.02 dia.
White (−)
(20)
(70)
150±1
32±2
80±10
M±1%
L: Protective tubing length
M: Lead wire length
Note: The sleeve resists temperatures ranging between 0°C
and 100°C.
Note: The protective tubing is of pipe construction, which must not be bent.
Protective tubing length (mm)
Lead wire length (m)
Element type: K (CA)
Element type: J (IC)
Model
65
100
150
200
1
E52-CA6ASY 1M
E52-IC6ASY 1M
2
E52-CA6ASY 2M
E52-IC6ASY 2M
4
E52-CA6ASY 4M
E52-IC6ASY 4M
1
E52-CA10ASY 1M
E52-IC10ASY 1M
2
E52-CA10ASY 2M
E52-IC10ASY 2M
4
E52-CA10ASY 4M
E52-IC10ASY 4M
1
E52-CA15ASY 1M
E52-IC15ASY 1M
2
E52-CA15ASY 2M
E52-IC15ASY 2M
4
E52-CA15ASY 4M
E52-IC15ASY 4M
1
E52-CA20ASY 1M
E52-IC20ASY 1M
2
E52-CA20ASY 2M
E52-IC20ASY 2M
4
E52-CA20ASY 4M
E52-IC20ASY 4M
18
E52
Exposed-lead Models with Screw
E52-CA1DY, E52-IC1DY
Specifications
Dimensions
Element type
K (CA), J (IC)
Element dia.
0.65 mm (single wire)
Class
Class 2 (0.75)
Protective tubing
material
SUS304
Thermal contact
Grounded type
Temperature range
0°C to 400°C: K (CA)
0°C to 350°C: J (IC)
Sleeve
(Brass nickel plated)
Movable ring (Brass)
End ring (Brass)
Shrinkable tube
(CA:Blue, IC:Yellow)
Screw
(SUS304)
Protective
copper wire
3.8±0.1 dia.
Lead wire
Fully glass-wool-covered
with external copper
shield and external
dimensions of approx.
3.1 x 2.0
1/0.65
0°C to 180°C
Terminal shape
Y-type crimp terminal for
M3.5
Note: 1. The thermocouple is a single wire from
the tip to the terminal.
2. Specify the type of screw (i.e., M6, M8, or
W1/4) when ordering.
3. The thermocouple is not of airtight
construction.
4. OMRON recommends that the tip of the
thermocouple is touching the sensing
object.
Lead wire
Crimping terminal
Y type for M3.5
Marking tube (White)
Red
Red (+)
PVC less tube
B
Blue
120°
9±1 5±0.05 dia.
3.8±1
2.8 +0.3
0
1±0.1
Black (−)
(20)
0
10 -0.5
A±0.3
M±1%
C
Internal Construction (E52-CA1DY)
0.65-dia.
black wire
Movable ring
Brass
Cut after silver
soldering
(70)
80±10
Closely wound
enamel-bonded coil.
M6
Lead wire
length (m)
Screw
W1/4
M6
M8
(P=1.27) (P=1.0) (P=1.25)
A (mm)
4.3
4
5.3
B (mm)
11.5
11.5
15
C (mm)
10
10
13
Brass pipe
Screw
Shielded
glass-wool lead
wire
Installation Example
Cut a thread into the workpiece, and screw in the
thermocouple while pushing in so that the tip
makes complete contact.
End
Workpiece
Note: E52-CA1DY with the same shape and multiple element wires are also available (E52-CA1DY-40).
Refer to page 29 for details.
Protective tubing length (mm)
Lead wire length (m)
Element type: K (CA)
Element type: J (IC)
Model
M6 screw
M8 screw
W1/4 screw
1
E52-CA1DY M6 1M
E52-IC1DY M6 1M
2
E52-CA1DY M6 2M
E52-IC1DY M6 2M
4
E52-CA1DY M6 4M
E52-IC1DY M6 4M
1
E52-CA1DY M8 1M
E52-IC1DY M8 1M
2
E52-CA1DY M8 2M
E52-IC1DY M8 2M
4
E52-CA1DY M8 4M
E52-IC1DY M8 4M
1
E52-CA1DY W1/4 1M
E52-IC1DY W1/4 1M
2
E52-CA1DY W1/4 2M
E52-IC1DY W1/4 2M
4
E52-CA1DY W1/4 4M
E52-IC1DY W1/4 4M
19
E52
Exposed-lead Models with Flange
Specifications
E52-CA6F-N, E52-IC6F-N
Element type
K (CA), J (IC)
Dimensions
Class
Class 2 (0.75)
Protective
tubing material
SUS304
Thermal contact Grounded type
Temperature
range
0°C to 350°C: K (CA)
0°C to 350°C: J (IC)
Lead wire
Fluororesin-covered
thermocouple wire (PFA) with
external dimensions of 1.6 x 1.0
1/0.32
0°C to 150°C
Silver brazing Siliconized
shrinkable tube
3×3.5 dia.
120°
120°
Shrinkable tube
(CA:Blue, IC:Yellow)
Flange (SUS304)
Product label
Lead wire
Protective tubing
(SUS304)
Peel treatment
Red (+)
White (−)
(10)
4±0.05 dia.
1
(75)
80±10
(30)
20 dia.
30 dia.
15
65±2
(30)
(M-16)
M±5%
Lead wire length (M): 1, 2, or 4 m
Note: 1. The thermocouple is a single wire from the tip to the terminal.
2. The protective tubing is of pipe construction, which must not be bent.
Lead wire
length (m)
Element type: K (CA)
Element type: J (IC)
Model
1
E52-CA6F-N 1M
E52-IC6F-N 1M
2
E52-CA6F-N 2M
E52-IC6F-N 2M
4
E52-CA6F-N 4M
E52-IC6F-N 4M
Exposed-lead Models with Screws
Specifications
E52-CA6D-N, E52-IC6D-N
Element type
K (CA), J (IC)
Dimensions
Class
Class 2 (0.75)
Protective
tubing material
SUS304
Taper screw for tube R1/8 (SUS304)
Siliconized shrinkable tube
Full-circled welding
Shrinkable tube (CA:Blue, IC:Yellow)
Product label
Peel treatment
Lead wire
Protective tubing (SUS304)
Thermal contact Grounded type
Temperature
range
Lead wire
Red (+)
(16)
0°C to 350°C: K (CA)
0°C to 350°C: J (IC)
Fluororesin-covered
thermocouple wire (PFA) with
external dimensions of 1.6 x 1.0
1/0.3
0°C to 150°C
4±0.05 dia.
(30)
14
(10)
(75)
80±10
(30)
65±2
White (−)
(M-16)
M±5%
15
Lead wire length (M): 1, 2, or 4 m
Note: 1. The thermocouple is a single wire from the tip to the terminal.
2. The protective tubing is of pipe construction, which must not be bent.
Lead wire
length (m)
Element type: K (CA)
Element type: J (IC)
Model
1
E52-CA6D-N 1M
E52-IC6D-N 1M
2
E52-CA6D-N 2M
E52-IC6D-N 2M
4
E52-CA6D-N 4M
E52-IC6D-N 4M
Exposed-lead Models
Specifications
E52-CA10AE-N, E52-IC10AE-N
Element type
K (CA), J (IC)
Dimensions
Class
Class 2 (0.75)
Protective
tubing material
SUS304
Fluorocarbon resin protective tubing
Protective tubing
3.2±0.05 dia. (SUS304)
Shrinkable tube
(CA:Blue, IC:Yellow)
Peel treatment
Product label
Red (+)
Thermal contact Non-grounded type
Temperature
range
0°C to 350°C: K (CA)
0°C to 200°C: J (IC)
Lead wire
Fluororesin-covered
thermocouple wire (PFA) with
external dimensions of 1.6 x 1.0
1/0.32
0°C to 180°C
Swage
Lead wire
(30)
M±5%
100±5
Note: 1.
2.
3.
4.
(10)
(75)
80±10
White (−)
The thermocouple is a single wire from the tip to the terminal.
Lead wire length M: 1, 2, or 4 m
The protective tubing is of pipe construction, which must not be bent.
The thermocouple cannot be mounted using a PT@ Compression Fitting.
Lead wire
length (m)
Element type: K (CA)
Element type: J (IC)
Model
1
E52-CA10AE-N 1M
E52-IC10AE-N 1M
2
E52-CA10AE-N 2M
E52-IC10AE-N 2M
4
E52-CA10AE-N 4M
E52-IC10AE-N 4M
20
E52
Exclusive Models
■ Thermocouples
Thermocouples for Molding Machines
Specifications
E52-CA2GVY, E52-IC2GVY
Element type
K (CA), J (IC)
Dimensions
Element
diameter
1.0 mm (single wire)
Class
Class 2 (0.75)
Protective
tubing material
SUS304
Thermal contact Grounded type
Temperature
range
0°C to 350°C
Lead wire
Glass-covered stainless steel
shielded thermocouple wire
with 4 dia.
1/1.0
0°C to 180°C
Spring retainer
(Brass nickel plated)
Bayonet
(Brass nickel plated)
Protective tubing
(SUS304)
Shrinkable tube
(CA:Blue, IC:Yellow)
Spring
15 dia.
6.8 dia.
Product label
Marking tube
Red
(Red)
Lead wire
4.8±0.05 dia.
25±2
15
White/Red Stripes (+)
White
Marking tube
(White)
(80)
85±10
(30)
20
100±10
Crimping terminal
Y type for M3.5
CA: White/Blue Stripes (−)
IC: White/Yellow Stripes (−)
M±5%
Taper screw for tube R1/8 (Brass nickel plated)
Note: The Adapter is included with
the Thermocouple.
If it is lost or damaged, you can
order a replacement with the
following model number.
Adapter: Y92F-S1
8 dia.12 dia.
10
5 dia.
10 15
Details of mounting bracket
Lead wire
length (m)
Element type: K (CA)
Lead wire length (M): 1 or 2 m
Element type: J (IC)
Model
1
E52-CA2GVY 1M
E52-IC2GVY 1M
2
E52-CA2GVY 2M
E52-IC2GVY 2M
Thermocouples with Crimp Terminals
Specifications
E52-CA1GTY, E52-IC1GTY
Element type
K (CA), J (IC)
Dimensions
Element
diameter
0.65 mm (single wire)
Class
Class 2 (0.75)
Thermal contact Grounded type
Temperature
range
0°C to 300°C
Lead wire
Glass-covered stainless steel
shielded thermocouple wire
with 4 dia.
1/1.0
0°C to 150°C
Terminal shape
Crimping terminal Y type for M3.5
Temperature
measuring junction
Marking tube
(White)
Shrinkable tube
(CA:Blue, IC:Yellow)
Crimping terminal
round type for M4
(N1.25-4)
Transparent vinyl tube
Siliconized
shrinkable tube
White/Red Stripes (+)
Product label
8
4.3 dia.
Max. 6 dia.
Lead wire
Transparent
15±5
30±5
White
(−)
(80)
90±10
M±4%
Lead wire length (M): 1 or 2 m
Y-type crimp terminal for M3.5
Note: The E52-CA1GTY is also available with double
elements. Refer to page 29 for details.
Lead wire
length (m)
Element type: K (CA)
Element type: J (IC)
Model
1
E52-CA1GTY 1M
E52-IC1GTY 1M
2
E52-CA1GTY 2M
E52-IC1GTY 2M
21
E52
■ Platinum Resistance Thermometers
Platinum Resistance Thermometers for Surface Temperature Measurement
Specifications
E52-P2GSY
Element type
Pt100
Dimensions
Class
Class B
Protective
tubing material
SUS304
With brass-nickelplated bracket
Conductor type
3-conductor system
Temperature
range
−50°C to 250°C
Lead wire
Silicone-covered
3-conductor cable
and approx. 3.9 dia.
30/0.08
−50°C to 150°C
Blacket
(Brass nickel plated)
4×3.2 dia.
Siliconized shrinkable tube
(7.5 dia.)
Lead wire
3
Crimping terminal Y type for M3.5
Marking tube (White)
Shrinkable tube Product label
(Black)
Red (A)
White (B)
5 20±1
White (B)
14±0.5
Transparent
20±0.5
1.5
4.5
30±5
(50)
6
28±1
(30)
(80)
M±4%
Lead wire length (m)
90±10
Lead wire length (M): 1 or 2 m
Model
1
E52-P2GSY 1M
2
E52-P2GSY 2M
Platinum Resistance Thermometers for Room Temperature Measurement
Specifications
E52-P10GRY
Element type
Pt100
Dimensions
Class
Class B
Protective
tubing material
SUS304
Conductor type
3-conductor system
Temperature
range
−50°C to 60°C
Lead wire
Vinyl-covered 3-conductor
cable with 6.1 dia.
20/0.18
−25°C to 60°C
Product label
Terminal box
85
2×8 dia.
60
70±1
42±1
69.5±1
Protective piping
(Brass nickel plated)
Crimping terminal Y type for M3.5
Chain
Marking tube (Red)
Protective tubing
(SUS304)
Red
Shrinkable tube (Black)
56±1
22.2±1 dia.
8 dia.
Red (A)
White (B)
4.8 dia.
Black (B)
Lead wire
4.5±1
(30)
(95)
100±4
97±1
Lead wire length (m)
2
White
Marking tube (White)
(80)
85±10
M±5%
Model
E52-P10GRY 2M
Waterproof Platinum Resistance Thermometers
Specifications
E52-P10GPY
Element wire
Pt100
Class
Class B
Protective tubing
material
SUS304
Conductor type
Vinyl-covered 3-conductor
cable with 6.1 dia.
12/0.18
−25°C to 60°C
Resistive pressure 981 kps
Crimping terminal
Y type for M3.5
Shrinkable tube (Black)
Protective tubing
(SUS304)
Marking tube (Red)
Sleeve (SUS304)
Full-circled
Welding
3-conductor system
Temperature range 0°C to 70°C (underwater)
−20°C to 70°C (in the air)
Lead wire
Dimensions
Red
Lead wire
Product label
Red (A)
White (B)
7±0.2 dia.
20 dia.
White
Marking tube (White)
(30)
(80)
85±10
M±5%
12
100±2
62
5
Black (B)
Lead wire length (M): 1 or 2 m
Note: The lead wires are vinyl-covered, and cannot be used underwater.
Use the E52-P5AY-40 if waterproof lead wires are required for use underwater.
Refer to page 24 for details.
Lead wire length (m)
Model
2
E52-P10GPY 2M
4
E52-P10GPY 4M
22
E52
Corrosion-resistant Models with Fluororesin-covered
Protective Tubing
■ Thermocouples
Exposed-lead Models
Specifications
E52-CA20AY-1
Element type
K (CA)
Class
Class 2 (0.75)
Protective tubing
material
ASTM316L with
Fluororesin-covered
(FEP) tube
Thermal contact
Non-grounded type
Temperature range
0°C to 180°C
Lead wire
Vinyl-covered: −20°C
to 70°C
Dimensions
Sheath (ASTM316L)
Ds±0.05
Shrinkable tube
(CA:Blue, IC:Yellow)
Fixed with adhesive tape and
siliconized shrinkable tube
Crimping terminal Y type for M3.5
Marking tube (White)
Sleeve (SUS304)
FEP-covered tubing
Product label
d
Red (+)
White (−)
D±0.1
5
22
+9
-5
Lead wire
8
Transparent
30±5
(L-5)
L
Model
+4
0
Protective
tubing
diameter
E52-CA20AY-1 D=4.6 2M D = 4.6
E52-CA20AY-1 D=6 2M D = 6.0
E52-CA20AY-1 D=8 2M D = 8.0
(80)
90±10
M±4%
55
Sleeve
diameter
(mm)
Sleeve length
(mm)
tube
thickness
(mm)
d=8
l = 55
0.7
d = 11
l = 55
0.8
Lead wire
length (m)
0.5
0.6
■ Platinum Measurement
Exposed-lead Models
Specifications
E52-P20AY-1
Element type
Pt100
Class
Class B
Protective tubing
material
SUS316 with
Fluororesin-covered
(FEP) tube
Conductor type
3-conductor system
Temperature range
−80°C to 180°C
Lead wire
Vinyl-covered: −20°C
to 70°C
Dimensions
Crimping terminal Y type for M3.5
Fixed with adhesive tape and
Tube nose shape :
siliconized shrinkable tube
Round
Marking tube
Sheath (SUS316)
Shrinkable tube (Black)
(Red)
FEP-covered
tubing
Red
Sleeve (SUS304)
Product label
Lead wire
Red (A)
White (B)
D±0.1
Ds±0.05
(10)
A
Black (B)
8 dia.
(10)
(20)
L+5 ±3%
Model
(30)
35
M±4%
Protective
tubing
diameter
Marking tube White
(White)
(80)
85±10
Sleeve
diameter
(mm)
Coating
thickness
(mm)
E52-P20AY-1 D=4.6
2M
D = 4.6
d=8
0.7
E52-P20AY-1 D=6 2M
D = 6.0
d=8
0.6
E52-P20AY-1 D=8 2M
D = 8.0
d=8
0.8
Lead wire
length (m)
2
23
E52
FEP-molded Models (Completely Waterproof)
Specifications
E52-P5AY-40
Element type
Pt100
Class
Class B
Protective tubing
material
Fluororesin (FEP) tube
(element / fluororesin
mold (FEP))
Conductor type
3-conductor system
Temperature range
−50°C to 180°C
Lead wire
Fluororesin (FEP)
cover (with outer
cover): −50°C to 180°C
Dimensions
Crimping terminal Y type for M3.5
Fusion
(Completely waterproof)
+0.1
6 -0.5 dia.
Lead wire
FEP tube
Transparent
Shrinkable tube (Black)
Product label
Marking tube (White)
Red (A)
White (B)
White (B)
+4
30±5
65 -1
(80)
90±10
M±4%
Model
Lead wire length (m)
E52-P5AY-40 2M
2
E52-P5AY-40 4M
4
E52-P5AY-40 6M
6
E52-P5AY-40 8M
8
24
E52
Pressure-resistant Explosion-proof (IICT6) Models
■ Thermocouples
Enclosed-terminal Models
E52-CA@@C-N-6
Dimensions
(131.5)
Explosion-proof display label
Back: Product label
110
L
L2±3%
L1=50
Official approval success label
Socket (SUS304)
Support (SUS304)
Sheath (ASTM316L)
15 dia.
(113)
6.4±0.05 dia.
Full-circled Welding
Cap
Terminal box
Chain
(64.5)
Pressure-resistant explosion-proof
cable ground
(Adopted cable diameter: for 9-10 dia.)
70
(10)
Specifications
Element type
K (CA)
Class
Class 2 (0.75)
Class 3 (Level 1.5) at 40°C and under
Protective tubing material
L2 section: ASTM316L
L1 section: SUS304
Explosion- Construction
Pressure-resistant
proof
explosion-proof structure
specifica- Explosion-protected IICT6
tions
class and ignitability
Explosion-proof
temperature range
−20°C to 85°C
Lead wire wiring
method
Pressure-resistant
packing cable ground type
Conduit thread
G1/2
Installation method
Conforms to Technical
Recommendations of the
Research Institute of
Industrial Safety (Japan)
Model
Protective
tubing length
L (cm)
Protective
tubing
diameter
L2
(mm)
E52-CA20C-N-6 D=6.4 L2=150
20
D = 6.4
150
E52-CA35C-N-6 D=6.4 L2=300
35
D = 6.4
300
E52-CA50C-N-6 D=6.4 L2=450
50
D = 6.4
450
E52-CA75C-N-6 D=6.4 L2=700
75
D = 6.4
700
25
E52
■ Platinum Resistance Thermometers for Surface Temperature Measurement
Enclosed-terminal Models
E52-P@@C-N-6
Dimensions
110
L
(131.5)
Explosion-proof display label
Back: Product label
L2±3%
L1=50
Official approval success label
Socket (SUS304)
15 dia.
Support (SUS304)
Sheath (ASTM316L)
(113)
6.4±0.05 dia.
Full-circled Welding
Cap
Terminal box
Chain
(64.5)
Pressure-resistant explosion-proof
cable ground
(Adopted cable diameter: for 9-10 dia.)
70
(10)
Specifications
Element type
Pt100
Class
Class B
Protective tubing material
L2 section: ASTM316L
L1 section: SUS304
Explosion- Construction
Pressure-resistant
proof
explosion-proof structure
specifica- Explosion-protected IICT6
tions
class and ignitability
Explosion-proof
temperature range
−20°C to 85°C
Lead wire wiring
method
Pressure-resistant
packing cable ground type
Conduit thread
G1/2
E52-P20C-N-6 D=6.4 L2=150
20
D = 6.4
150
Conforms to Technical
Recommendations of the
Research Institute of
Industrial Safety (Japan)
E52-P35C-N-6 D=6.4 L2=300
35
D = 6.4
300
E52-P50C-N-6 D=6.4 L2=450
50
D = 6.4
450
E52-P75C-N-6 D=6.4 L2=700
75
D = 6.4
700
Installation method
Model
Protective
tubing length
L (cm)
Protective
tubing
diameter
L2
(mm)
26
E52
Double-element Models
■ Thermocouple
Exposed-lead Models
Specifications
E52-CA20AY-7
Element type
K (CA)
Dimensions
Class
Class 2 (0.75)
Thermal contact
Non-grounded type
Temperature
range
0°C to permissible
temperature limit
Lead wire
Vinyl-covered with
external dimensions of
2.4 x 4.1
7/0.3
−20°C to 70°C
Product label
Sleeve (SUS304)
Protective tubing ASTM316L
material
(with sheath)
Sheath (ASTM316L)
Crimping terminal Y type for M3.5
Transparent
Marking tube
(White)
Shrinkable tube (Blue)
Swage
Lead wire
11 dia.
D±0.05
30±5
L±3%
Red (+)
White (−)
Red (+)
White (−)
(80)
90±10
M±4%
55
Permissible Temperature in Dry Air
D
Element wire
K (CA)
ASTM316L
3.2 dia.
750°C
4.8 dia.
800°C
6.4 dia.
800°C
8.0 dia.
900°C
Model
Protective
tubing
diameter
Sleeve
diameter
(mm)
Permissible Lead wire
Temperature length (m)
(°C)
E52-CA20AY-7 D=3.2
2M
D = 3.2
d = 11
750
2
E52-CA20AY-7 D=4.8
2M
D = 4.8
d = 11
800
2
E52-CA20AY-7 D=6.4
2M
D = 6.4
d = 11
800
2
E52-CA20AY-7 D=8.0
2M
D = 8.0
d = 11
900
2
■ Platinum Resistance Thermometers
Exposed-lead Models
Specifications
E52-P20AY-7
Element type
Pt100
Dimensions
Class
Class B
Protective tubing ASTM316L
material
(with sheath)
Conductor type
3-conductor system
Temperature
range
−200°C to 450°C
Lead wire
Vinyl-covered with 6.5
dia.
19/0.18
−20°C to 70°C
Wire mark (1,2) (White)
Contradistinctive view
Shrinkable tube (Black)
Sleeve (SUS304)
Sheath (ASTM316L)
Marking tube
(White)
Product label
Lead wire
11 dia.
Swage
D±0.05
Crimping terminal
Y type for M3.5
Transparent
Red (A)
White (B)
White/Black
Stripes (B)
Red (A)
1
2
White (B)
30±5
L±3%
Model
55
(80)
M±4%
Protective
tubing diameter
White/Black
Stripes (B)
90±10
Lead wire
length (m)
E52-P20AY-7 D=4.8 2M
D = 4.8
2
E52-P20AY-7 D=6.4 2M
D = 6.4
2
27
E52
Enclosed-terminal Models
Specifications
E52-P20C-N-7
Element type
Pt100
Class
Class B
Protective tubing
material
ASTM316L
(with sheath)
Conductor type
3-conductor system
Temperature range
−200°C to 450°C
Dimensions
(92)
Cap
Product label
Socket (SUS304)
38 dia.
Swage
82 dia.
Sheath (ASTM316L)
D±0.05
(86)
Chain
G3/4
(Packing internal
diameter : 12 dia.)
(15)
Terminal box
53
Model
L-50±3%
Protective tubing
Protective
length L (cm)
tubing diameter
E52-P20C-N-7 D=4.8
20
D = 4.8
E52-P20C-N-7 D=6.4
20
D = 6.4
Note: The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-P20C-N-7: L = 20 (cm), the sheath length L − 50 = 200 − 50 = 150 mm.
28
E52
Silicone-covered Lead Wires Models
■ Thermocouples
Exposed-lead Models with Screws
Specifications
Element type
K (CA)
Class
Class 2 (0.75)
Screw material
SUS304
Thermal contact
Grounded type
Temperature range
0°C to 300°C
Lead wire
Silicone-covered with external dimensions of 3.5 x 4.9
30/0.1
0°C to 150°C
Terminal shape
Y-type crimp terminal for M3.5
Note: Refer to the installation example for the E52-CA1DY.
E52-CA1DY-40
Dimensions
Screw (SUS304)
Crimping terminal Y type for M3.5
Sleeve (Brass nickel plated)
Marking tube (White)
Protective spring (SUS304)
Red
8±0.05 dia.
Shrinkable tube (Blue)
Red (+)
0.6 dia. +0.05
Lead wire
6.5 0 dia.
Movable ring (Brass)
End ring (Brass)
3.8±0.1 dia.
B
Blue
120°
13±1
2.8 +0.3
0
1±0.1
10
White (−)
80±5
0
-0.5
(20)
A±0.3
(70)
80±10
M±1%
C
Model
Screw pitch
Lead wire
length (m)
E52-CA1DY-40 M6 1M
M6 (P=1.0)
1
E52-CA1DY-40 M6 2M
M6 (P=1.0)
2
E52-CA1DY-40 M6 4M
M6 (P=1.0)
4
Thermocouples with Crimp Terminals
Specifications
Element type
K (CA)
Class
Class 2 (0.75)
Thermal contact
Grounded type
Temperature range
0°C to 200°C
Lead wire
Silicone-covered compensating cable with external dimensions of 3.2 x 4.6
30/0.1
0°C to 150°C
Terminal shape
Y-type crimp terminal for M3.5
E52-CA1GTY-14
Dimensions
Crimping terminal round type for M4 (N1.25-4)
Siliconized shrinkable tube
Shrinkable tube
(CA:Blue, IC:Yellow)
6.6
Max. 7 dia.
Crimping terminal Y type for M3.5
Transparent
Marking tube (White)
Red (+)
Product label
Lead wire
Lead wire length (M): 1 or 2 m
4.3 dia.
White (−)
15±5
30±5
(80)
90±10
Model
Lead wire length (m)
E52-CA1GTY-14 1M
1
E52-CA1GTY-14 2M
2
M±4%
29
E52
Thermistors
Element Interchangeable Thermistor for E5CS and E5C2
Temperature Ranges
Temperature
range
Color code
Nominal resistance
Thermistor
constant
−50°C to 50°C
Blue
6 kΩ (0°C)
3390K
0°C to 100°C
Black
6 kΩ (0°C)
3390K
50°C to 150°C
Red
30 kΩ (0°C)
3450K
100°C to 200°C
Yellow
0.55 kΩ (200°C)
4300K
150°C to 300°C
Green
4 kΩ (200°C)
5133K
Lead wire
A pair of 0.12 dia. 7 Fluororesin-insulated stranded wires with
0.86 outer dia. each
Flat glass-wool-shielded lead cable with 0.12 dia. 10 conductors
and external dimensions of 2.5 × 1.55
Specifications
Item
Coupling method
E52-THE@@
Element interchangeable thermistor
Class
JIS class 1
Protective tubing material
SUS304
Time constant
8 to 15 s in still water
Dissipation factor
2.4 to 2.8 mW/°C in still air
Lead wire heat resistive
temperature
180°C
Error
Detectable temperature
Error
−50°C to 100°C
±1°C max.
100°C to 350°C
±1% max. of detectable temperature
Permissible Temperature
Detectable temperature
Operating temperature
−50°C to 50°C
100°C
0°C to 100°C
150°C
50°C to 150°C
200°C
100°C to 200°C
250°C
150°C to 300°C
350°C
Note: Models with non-standard lead wire length and protective
tubing length are available on request.
This Thermistor is a dedicated Thermistor for the E5C2 and E5CS.
30
E52
Exposed-lead Models
E52-THE5A
Dimensions
Temperature range
Protective tubing
(SUS304)
Protective tube
Lead wire
Swage
4±0.08 dia.
(5)
(4)
Transparent
Peel treatment
Marking tube
(15)
(10)
(50)
M±5%
50±1
Model
−50°C to 50°C
E52-THE5A −50-50°C 1M
0°C to 100°C
E52-THE5A 0-100°C 1M
50°C to 150°C
E52-THE5A 50-150°C 1M
100°C to 200°C
E52-THE5A 100-200°C 1M
150°C to 300°C
E52-THE5A 150-300°C 1M
Note: The lead wires have no polarity
Exposed-lead Models with Screws
E52-THE6D
Dimensions
Protective tubing
(SUS304)
10
6
Protective tube
Swage
4±0.08 dia.
Lead wire
Marking tube
Peel treatment
Transparent
(16)
Tapered screw
for tube R1/8
14
(5)
(SUS304)
65±1
(4)
(15)
(15)
(50)
(10)
Temperature range
Model
−50°C to 50°C
E52-THE6D −50-50°C 1M
0°C to 100°C
E52-THE6D 0-100°C 1M
50°C to 150°C
E52-THE6D 50-150°C 1M
100°C to 200°C
E52-THE6D 100-200°C 1M
150°C to 300°C
E52-THE6D 150-300°C 1M
M±5%
Note: The lead wires have no polarity
Exposed-lead Models with Flange
E52-THE6F
Dimensions
Flange (SUS304)
3×3.5 dia.
120°
120°
Protective tubing
(SUS304)
Swage
65±1
(4)
(15)
Peel treatment
Lead wire
(15)
(5)
20 dia.
30 dia.
Marking tube
Transparent
Protective tube
(1)
4±0.08 dia.
Temperature range
Silver brazing
(50)
Model
−50°C to 50°C
E52-THE6F −50-50°C 1M
0°C to 100°C
E52-THE6F 0-100°C 1M
50°C to 150°C
E52-THE6F 50-150°C 1M
100°C to 200°C
E52-THE6F 100-200°C 1M
150°C to 300°C
E52-THE6F 150-300°C 1M
(10)
M±5%
Note: The lead wires have no polarity
Note: 1. The Thermistor lead cable can be extended with a standard lead wire for extension.
2. Be sure to specify the model and temperature range when ordering the Thermistor. The Thermistor has a color code according to the
temperature range.
31
E52 (Ferrule)
General-purpose Models (with Ferrule)
■ Model Number Legend
The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below.
Platinum Resistance Thermometers
1. Element type
P: Pt100
2. Protective tubing length (L)
Specify the length in centimeters within the following range:
Unit (cm)
E52-P@AF
Diameter (D)
Length (L)
3.2
7 to 100
4.8
10 to 600
6.4
13 to 1,300
4. Diameter
3.2: 3.2-mm dia. (Protective tubing construction: Sheathed)
E52-@@AF only
4.8: 4.8-mm dia. (Protective tubing construction: Sheathed)
E52-@@AF only
6.4: 6.4-mm dia. (Protective tubing construction: Sheathed)
E52-@@AF only
5. Heat resistance
Code
3. Terminal
AF: Exposed lead wires (with Ferrule)
Temperature range
Lead type
---
−20°C to 70°C
Sleeve: 0°C to 70°C
Vinyl-covered
NETU
0°C to 180°C
Sleeve: 0°C to 100°C
Glass-wool-covered,
externally shielded with
stainless
Specify for E52-P@AF model only.
6. Lead length (M)
Specify the length in meters within the following range for the E52@@AF only:
Range: 0.5, 1 to 100 m
Examples
Element: Pt100, protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m
E52-P42AF D=4.8 NETU 10M
■ Sheathed Platinum Resistance Thermometers
Refer to Model Number Legend above for the Pt100.
Specifications
Element type
Pt100
Class
JIS class B
Sheath material
SUS316 (E52-P@AF)
ASTM316L (E52-P@B-N, E52-P@C-N)
Sheath outer diameter
3.2 dia., 4.8 dia., 6.4 dia., 8 dia
Conductor type
3-conductor system
Temperature range
−196°C to 450°C (in dry air)
32
E52 (Ferrule)
Exposed-lead Models
E52-P@AF
Dimensions
Lead Wire
Ferrule *
SUS304
sleeve
Sheath
(SUS316)
Shrinkable tube (black)
Caulking
D±0.05
8 dia.
• Standard (−20°C to 70°C):
Fully vinyl-covered with twelve 0.18-dia
conductors (0.3 mm thick) and 4.8 mm
in outer dia. The sleeve resists a
temperature range between 0°C and
70°C.
• Heat Resistive (0°C to 180°C):
Fully glass-wool-covered with thirty
0.12-dia. conductors (0.3 mm thick)
externally shielded with stainless steel,
4 mm in outer dia. The sleeve resists a
temperature range between 0°C and
100°C.
• Lead Wire Length (M): 1, 2, 4, or 8 m
Turquoise
Product label
Lead wire
Maker tube
Red (A)
A
B
White (B)
B
Black (B)
(30)
40
L±3%
M±4%
85±10
* Ferrule Dimensions
Cross-sectional diameter: 2 mm max.
Length: 9 mm max.
Model Information
Custom-made models are available on request. Refer to page 32 for details.
Terminal type
Protective
tubing
diameter D
(mm)
Exposed-lead 3.2 dia.
Models
Protective
tubing length
L (cm)
15
20
35
4.8 dia.
20
35
50
Lead wire
type
Lead wire length M (m)
1
2
4
8
Model
Standard
E52-P15AF D=3.2 E52-P15AF D=3.2 E52-P15AF D=3.2 E52-P15AF D=3.2
1M
2M
4M
8M
Heat resistive
E52-P15AF D=3.2 E52-P15AF D=3.2 E52-P15AF D=3.2 E52-P15AF D=3.2
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P20AF D=3.2 E52-P20AF D=3.2 E52-P20AF D=3.2 E52-P20AF D=3.2
1M
2M
4M
8M
Heat resistive
E52-P20AF D=3.2 E52-P20AF D=3.2 E52-P20AF D=3.2 E52-P20AF D=3.2
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P35AF D=3.2 E52-P35AF D=3.2 E52-P35AF D=3.2 E52-P35AF D=3.2
1M
2M
4M
8M
Heat resistive
E52-P35AF D=3.2 E52-P35AF D=3.2 E52-P35AF D=3.2 E52-P35AF D=3.2
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P20AF D=4.8 E52-P20AF D=4.8 E52-P20AF D=4.8 E52-P20AF D=4.8
1M
2M
4M
8M
Heat resistive
E52-P20AF D=4.8 E52-P20AF D=4.8 E52-P20AF D=4.8 E52-P20AF D=4.8
NETU 1M
NETU 2M
NETU 4M
NETU 8M
Standard
E52-P35AF D=4.8 E52-P35AF D=4.8 E52-P35AF D=4.8 E52-P35AF D=4.8
1M
2M
4M
8M
Heat resistive
E52-P35AF D=4.8 E52-P35AF D=4.8 E52-P35AF D=4.8 E52-P35AF D=4.8
NETU 1M
NETU 2M
NETU 4M
NETU 8M
E52-P50AF D=4.8 E52-P50AF D=4.8 E52-P50AF D=4.8 E52-P50AF D=4.8
8M
4M
1M
2M
Standard
Heat resistive
E52-P50AF D=4.8 E52-P50AF D=4.8 E52-P50AF D=4.8 E52-P50AF D=4.8
NETU 1M
NETU 2M
NETU 4M
NETU 8M
33
E52 (Ferrule)
■ Model Number Legend
The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below.
Thermocouples
1. Element type
CA:K
2. Protective tubing length (L)
Specify the length in centimeters in the following range: Unit (cm)
E52-CA@AF (Exposed-lead Model)
Diameter (D)
Length (L)
1
2 to 200
1.6
3 to 500
3.2
5 to 2,000
4.8
8 to 2,300
6.4
10 to 1,200
8
12 to 1,000
3. Terminal
AF: Exposed lead wires (with Ferrule) (element type: K, J)
4. Diameter
Specify the protective tubing material according to the table.
Code
Diameter Protective tubing
(D)
construction
Protective tubing
material
1
1 mm
Sheathed
ASTM316L
1.6
1.6 mm
Sheathed
ASTM316L
3.2
3.2 mm
Sheathed
ASTM316L
4.8
4.8 mm
Sheathed
ASTM316L
6.4
6.4 mm
Sheathed
ASTM316L
8
8 mm
Sheathed
ASTM316L
5. Heat resistance
Specify this item for the exposed-lead models only.
Code
Temperature range
Lead type
---
−20°C to 70°C
Sleeve: 0°C to 70°C
Vinyl-covered
NETU
0°C to 150°C
Sleeve: 0°C to 100°C
Glass-wool-covered with external shield of stainless
6. Lead length (M)
Specify the length in meters in the following range for the E52-CA@AF only.
Range: 1 to 100 m
7. Protective tubing material
Code
---
Protective tubing
material
ASTM316L
Element type
K
Examples
Element: K; protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m
E52-CA@AF D=4.8 NETU 10M
34
E52 (Ferrule)
■ Sheathed Thermocouples
Specifications
Permissible Temperature in Dry Air
D
Element type
K (CA)
Class
JIS class 2 (0.75)
Thermal contact
Non-grounded type
Sheath material
CA: ASTM316L
Element wire
K (CA)
ASTM316L
IC: ASTM316L
1 dia.
650°C
1.6 dia.
650°C
3.2 dia.
750°C
4.8 dia.
800°C
6.4 dia.
800°C
8.0 dia.
900°C
Note: For details on the permissible temperature, refer to page D-5 of
Introduction of Temperature Controllers (Cat. No. H900).
Exposed-lead Models
E52-CA@AF
Dimensions
Sheath
(ASTM316L)
Shrinkable tube (blue)
SUS304
sleeve
Ferrule *
White
Maker tube
Red (+)
Product label
Caulking
D±0.05
d
Lead wire
* Ferrule Dimensions
Cross-sectional diameter: 2 mm max.
Length: 9 mm max.
White (−)
(80)
30±5
L±3%
55
M±4%
90±10
Note: 1. Lead Wire (Compensating Conductor)
• Standard (−20°C to 70°C):
Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm
thick) and external dimensions of 2.4 × 4.1.
• Heat Resistive (0°C to 150°C):
Fully glass-wool-covered with seven 0.3-dia. conductors
(0.5 mm thick) with external shield of stainless steel and
external dimensions of 2.8 × 4.6
The heat-resistive lead wires cannot be used in locations
exposed to water or other liquids.
• Lead Wire Length (M): 1, 2, 4, or 8 m
2. The sleeve resists temperatures ranging between −20°C and
70°C for standard models and 0°C and 100°C for heat-resistive
models.
Permissible Temperature in Dry Air
D
Unit (mm)
D
d
Element wire
J (IC)
ASTM316L
l
1 dia.
8
55
1 dia.
450°C
1.6 dia.
8
55
1.6 dia.
450°C
3.2 dia.
8
55
3.2 dia.
650°C
4.8 dia.
8
55
4.8 dia.
750°C
6.4 dia.
11
55
6.4 dia.
750°C
8 dia.
11
55
8.0 dia.
750°C
35
E52 (Ferrule)
K (CA) Model Information (E52-CA@AF)
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 34 for details.
Terminal type
Protective
Protective
tubing diameter tubing length L
D (mm)
(cm)
Lead wire type
Lead wire length M (m)
1
2
4
8
Model
Exposed-lead
Models
1 dia.
15
20
35
1.6 dia.
15
20
35
Exposed-lead
Models
3.2 dia.
15
20
35
50
4.8 dia.
20
35
50
Standard
E52-CA15AF D=1 1M E52-CA15AF D=1 2M E52-CA15AF D=1 4M E52-CA15AF D=1 8M
Heat resistive
E52-CA15AF D=1
NETU 1M
Standard
E52-CA20AF D=1 1M E52-CA20AF D=1 2M E52-CA20AF D=1 4M E52-CA20AF D=1 8M
Heat resistive
E52-CA20AF D=1
NETU 1M
Standard
E52-CA35AF D=1 1M E52-CA35AF D=1 2M E52-CA35AF D=1 4M E52-CA35AF D=1 8M
Heat resistive
E52-CA35AF D=1
NETU 1M
E52-CA35AF D=1
NETU 2M
E52-CA35AF D=1
NETU 4M
E52-CA35AF D=1
NETU 8M
Standard
E52-CA15AF D=1.6
1M
E52-CA15AF D=1.6
2M
E52-CA15AF D=1.6
4M
E52-CA15AF D=1.6
8M
Heat resistive
E52-CA15AF D=1.6
NETU 1M
E52-CA15AF D=1.6
NETU 2M
E52-CA15AF D=1.6
NETU 4M
E52-CA15AF D=1.6
NETU 8M
Standard
E52-CA20AF D=1.6
1M
E52-CA20AF D=1.6
2M
E52-CA20AF D=1.6
4M
E52-CA20AF D=1.6
8M
Heat resistive
E52-CA20AF D=1.6
NETU 1M
E52-CA20AF D=1.6
NETU 2M
E52-CA20AF D=1.6
NETU 4M
E52-CA20AF D=1.6
NETU 8M
Standard
E52-CA35AF D=1.6
1M
E52-CA35AF D=1.6
2M
E52-CA35AF D=1.6
4M
E52-CA35AF D=1.6
8M
Heat resistive
E52-CA35AF D=1.6
NETU 1M
E52-CA35AF D=1.6
NETU 2M
E52-CA35AF D=1.6
NETU 4M
E52-CA35AF D=1.6
NETU 8M
Standard
E52-CA15AF D=3.2
1M
E52-CA15AF D=3.2
2M
E52-CA15AF D=3.2
4M
E52-CA15AF D=3.2
8M
Heat resistive
E52-CA15AF D=3.2
NETU 1M
E52-CA15AF D=3.2
NETU 2M
E52-CA15AF D=3.2
NETU 4M
E52-CA15AF D=3.2
NETU 8M
Standard
E52-CA20AF D=3.2
1M
E52-CA20AF D=3.2
2M
E52-CA20AF D=3.2
4M
E52-CA20AF D=3.2
8M
Heat resistive
E52-CA20AF D=3.2
NETU 1M
E52-CA20AF D=3.2
NETU 2M
E52-CA20AF D=3.2
NETU 4M
E52-CA20AF D=3.2
NETU 8M
Standard
E52-CA35AF D=3.2
1M
E52-CA35AF D=3.2
2M
E52-CA35AF D=3.2
4M
E52-CA35AF D=3.2
8M
Heat resistive
E52-CA35AF D=3.2
NETU 1M
E52-CA35AF D=3.2
NETU 2M
E52-CA35AF D=3.2
NETU 4M
E52-CA35AF D=3.2
NETU 8M
Standard
E52-CA50AF D=3.2
1M
E52-CA50AF D=3.2
2M
E52-CA50AF D=3.2
4M
E52-CA50AF D=3.2
8M
Heat resistive
E52-CA50AF D=3.2
NETU 1M
E52-CA50AF D=3.2
NETU 2M
E52-CA50AF D=3.2
NETU 4M
E52-CA50AF D=3.2
NETU 8M
Standard
E52-CA20AF D=4.8
1M
E52-CA20AF D=4.8
2M
E52-CA20AF D=4.8
4M
E52-CA20AF D=4.8
8M
Heat resistive
E52-CA20AF D=4.8
NETU 1M
E52-CA20AF D=4.8
NETU 2M
E52-CA20AF D=4.8
NETU 4M
E52-CA20AF D=4.8
NETU 8M
Standard
E52-CA35AF D=4.8
1M
E52-CA35AF D=4.8
2M
E52-CA35AF D=4.8
4M
E52-CA35AF D=4.8
8M
Heat resistive
E52-CA35AF D=4.8
NETU 1M
E52-CA35AF D=4.8
NETU 2M
E52-CA35AF D=4.8
NETU 4M
E52-CA35AF D=4.8
NETU 8M
Standard
E52-CA50AF D=4.8
1M
E52-CA50AF D=4.8
2M
E52-CA50AF D=4.8
4M
E52-CA50AF D=4.8
8M
Heat resistive
E52-CA50AF D=4.8
NETU 1M
E52-CA50AF D=4.8
NETU 2M
E52-CA50AF D=4.8
NETU 4M
E52-CA50AF D=4.8
NETU 8M
E52-CA15AF D=1
NETU 2M
E52-CA20AF D=1
NETU 2M
E52-CA15AF D=1
NETU 4M
E52-CA20AF D=1
NETU 4M
E52-CA15AF D=1
NETU 8M
E52-CA20AF D=1
NETU 8M
36
E52 (Ferrule)
Low-cost Models (with Ferrule)
■ Low-cost Platinum Resistance Thermometers
Exposed-lead Models with Screws
Specifications
E52-P6DF
Element type
Pt100
Dimensions
Conductor type
3-conductor system
Class
Class B
Protective tubing
material
SUS304
Sensor length
30 mm
Max. detectable
temperature
250°C
Temperature
range
−50°C to 250°C
Lead wire
Fluororesin-covered
wire (PFA) and
approx. 1.0 dia.
7/0.18
−50°C to 150°C
Tapered pipe thread
Full-circled welding SUS304
R1/8
Silicon
SUS304
shrinkable tube
protective
4 dia.±0.4
tubing
Ferrule *
Maker tube
Lead wire
Yellow
Red (A)
A
B
(16)
Black (B)
B
White (B)
6±0.5
10±0.5
14
Product label
(30)
65
0
-2
(M-16)
M±5%
15
Note: The protective tubing is of pipe construction, which must not be bent.
Lead wire length (m)
Model
1
E52-P6DF 1M
2
E52-P6DF 2M
4
E52-P6DF 4M
* Ferrule Dimensions
Cross-sectional diameter: 2 mm max.
Length: 9 mm max.
Exposed-lead Models with Flange
Specifications
E52-P6FF
Element wire
Pt100
Dimensions
Conductor type
3-conductor system
Class
Class B
Protective tubing
material
SUS304
Three, 3.5 dia.
120°
120°
4 dia.±0.4
Flange (SUS304)
SUS304 protective
tubing
Ferrule *
Nickel soldering
Maker tube
Silicon
shrinkable tube
Yellow
Lead wire
Red (A)
A
Sensor length
30 mm
Max. detectable
temperature
250°C
Temperature
range
−50°C to 250°C
Lead wire
Fluororesin-covered
wire (PFA) and
approx. 1.0 dia.
7/0.18
−50°C to 150°C
Black (B)
B
B
White (B)
Product label
1
20 dia.
(30)
30 dia.
65
0
-2
(M-16)
M±5%
15
Note: The protective tubing is of pipe construction, which must not be bent.
Lead wire length (m)
Model
1
E52-P6FF 1M
2
E52-P6FF 2M
4
E52-P6FF 4M
* Ferrule Dimensions
Cross-sectional diameter: 2 mm max.
Length: 9 mm max.
Exposed-lead Models
Specifications
E52-P10AEF
Element type
Pt100
Dimensions
Conductor type
3-conductor system
Class
Class B
Protective tubing
material
SUS316
Max. detectable
temperature
250°C
Temperature
range
0°C to 250°C
Lead wire
Fluororesin-covered
wire (PFA) and
approx. 1.0 dia.
7/0.2
−50°C to 150°C
Ferrule *
Shrinkable tube (black)
Product label
Silicon
SUS316 protective shrinkable tube
3.2±0.05 dia. tubing
Maker tube Yellow
Red (A)
Lead wire
A
B
White (B)
B
White (B)
30
30±5
80±10
M±4%
100±3%
Note: 1. The protective tubing is of pipe construction, which must not be bent.
2. A Compression Fitting (PT@) cannot be used for mounting.
Lead wire length (m)
Model
1
E52-P10AEF 1M
2
E52-P10AEF 2M
4
E52-P10AEF 4M
* Ferrule Dimensions
Cross-sectional diameter: 1.5 mm max.
Length: 9 mm max.
37
E52 (Ferrule)
■ Low-cost Thermocouples
Exposed-lead Models with Screw
E52-CA1DF
Specifications
Element type
K (CA)
Element dia.
0.65 mm (single wire)
Class
Class 2 (0.75)
Protective tubing
material
SUS304
Thermal contact
Grounded type
Temperature range
0°C to 400°C: K (CA)
Lead wire
Fully glass-woolcovered with external
copper shield and
external dimensions of
approx. 3.1 x 2.0
1/0.65
0°C to 180°C
Dimensions
Movable ring (brass)
C
Sleeve
Ferrule *
Shrinkable tube
Turquoise
SUS304 (Brass-nickel plating) (CA: Blue,
Top ring (brass) screw
Protective
IC: Yellow)
Maker tube
copper wire
Lead wire
+
Terminal shape
B
Red (+)
5±0.05 dia.
120°
3.8±0.1
2.8 +0.3
0
1±0.1
0
10 -0.5
-
9±1
3.8±1
Black (−)
(70)
80±10
(20)
A±0.3
M±1%
* Ferrule Dimensions
Cross-sectional diameter: 1.5 mm max.
Length: 9 mm max.
Internal Construction (E52-CA1DF)
0.65-dia.
black wire
Movable ring
Brass
Ferrule
Note: 1. The thermocouple is a single wire from
the tip to the terminal.
2. Specify the type of screw (i.e., M6, M8,
or W1/4) when ordering.
3. The thermocouple is not of airtight
construction.
4. OMRON recommends that the tip of
the thermocouple is touching the
sensing object.
Cut after silver
soldering
Closely wound
enamel-bonded coil.
M6
Brass pipe
Screw
Lead wire
length (m)
Screw
W1/4
M6
M8
(P=1.27) (P=1.0) (P=1.25)
A (mm)
4.3
4
B (mm)
11.5
11.5
5.3
15
C (mm)
10
10
13
Shielded
glass-wool lead
wire
Installation Example
Cut a thread into the workpiece, and screw in the
thermocouple while pushing in so that the tip
makes complete contact.
End
Workpiece
Note: E52-CA1DF with the same shape and multiple element wires are also available (E52-CA1DF-40).
Refer to page 42 for details.
Protective tubing length (mm)
Lead wire length (m)
Element type: K (CA)
Model
M6 screw
M8 screw
W1/4 screw
1
E52-CA1DF M6 1M
2
E52-CA1DF M6 2M
4
E52-CA1DF M6 4M
1
E52-CA1DF M8 1M
2
E52-CA1DF M8 2M
4
E52-CA1DF M8 4M
1
E52-CA1DF W1/4 1M
2
E52-CA1DF W1/4 2M
4
E52-CA1DF W1/4 4M
38
E52 (Ferrule)
Exclusive Models (with Ferrule)
■ Thermocouples
Thermocouples for Molding Machines
Specifications
E52-CA2GVF
Element type
K (CA)
Dimensions
Element
diameter
1.0 mm (single wire)
Class
Class 2 (0.75)
Protective
tubing material
SUS304
Spring retainer
Bayonet
(Brass-nickel plating)
(Brass-nickel plating)
SUS304
protective
15 dia.
tubing
Product label
Spring
Shrinkable tube
(Blue)
Ferrule *
Marker White
tube
Lead wire
4.8±0.05 dia.
Thermal contact Grounded type
0°C to 350°C
Lead wire
Glass-covered stainless
steel shielded thermocouple
wire with 4 dia.
1/1.0
0°C to 180°C
R1/8
White/red stripe (+)
8 dia.12 dia.
+
−
Temperature
range
5 dia.
25±2
15
6.8 20
dia.
100±10
(30)
(80)
85±10
M±5%
Lead wire
length (m)
Element type: K (CA)
Model
1
E52-CA2GVF 1M
2
E52-CA2GVF 2M
CA: White/blue stripe
IC: White/yellow stripe (−)
10
10 15
Note: The Adapter is included with
the Thermocouple.
If it is lost or damaged, you
can order a replacement with
the following model number.
Adapter: Y92F-S1
* Ferrule Dimensions
Cross-sectional diameter: 2 mm max.
Length: 9 mm max.
Thermocouples with Crimp Terminals
Specifications
E52-CA1GTF
Element type
K (CA)
Dimensions
Element
diameter
0.65 mm (single wire)
Class
Class 2 (0.75)
M4, round crimp terminal
(N1.25-4)
Thermal contact Grounded type
Temperature
range
0°C to 300°C
Lead wire
Glass-wool-braided shield
with maximum external
dimensions of 2.6 x 4.0
1/0.65
0°C to 150°C
Terminal shape
Shrinkable tube
(Blue)
Silicone
shrinkable tubing
Lead wire
6.6
Ferrule *
Marker tube
Product label
White/red stripe (+)
+
Turquoise
Sensing point
4.3 dia.
−
White stripe (−)
6 dia. max.
(80)
30±5
15±5
90±10
M±4%
Lead wire
length (m)
Ferrule
Note: The E52-CA1GTF is also available with
double elements. Refer to page 42 for
details.
Element type: K (CA)
Model
1
E52-CA1GTF 1M
2
E52-CA1GTF 2M
* Ferrule Dimensions
Cross-sectional diameter: 1.5 mm max.
Length: 9 mm max.
■ Platinum Resistance Thermometers
Platinum Resistance Thermometers for Surface Temperature Measurement
Specifications
E52-P2GSF
Element type
Pt100
Dimensions
Class
Class B
Protective
tubing material
SUS304
With brass-nickelplated bracket
Conductor type
3-conductor system
Temperature
range
−50°C to 250°C
Lead wire
Silicone-covered
3-conductor cable
and approx. 3.9 dia.
30/0.08
−50°C to 150°C
Brass-nickel-plated bracket
Silicon
Four, 3.2 dia.
shrinkable tube
(7.5-dia.)
3
5
1.5
4.50
6
Ferrule *
Lead wire
Product label
Shrinkable tube
(Black)
Marker tube Yellow
Red (A)
A
B
20±1
White (B)
B
14±0.5
White (B)
20±0.5
30±5
(50)
28±1
Lead wire length (m)
(30)
M±4%
Model
1
E52-P2GSF 1M
2
E52-P2GSF 2M
(80)
90±10
* Ferrule Dimensions
Cross-sectional diameter: 1.5 mm max.
Length: 9 mm max.
39
E52 (Ferrule)
Platinum Resistance Thermometers for Room Temperature Measurement
Specifications
E52-P10GRF
Element type
Pt100
Class
Class B
Protective tubing
material
SUS304
Conductor type
3-conductor system
Dimensions
Product label
Terminal box
85
Two, 8 dia.
60 42±1
70±1 dia.
Temperature range −50°C to 60°C
Lead wire
Vinyl-covered
3-conductor cable with
6.1 dia.
20/0.18
−20°C to 60°C
69.5±1
22.2±1 dia.
Protective pipe (Brass-nickel plating)
8.0 dia.
SUS304 protective
tubing
Chain
Ferrule *
Lead wire
56±1
White
Shrinkable tube
(Black)
Red (A)
A
B
White (B)
B
Black (B)
4.8 dia.
Marker tube
4.5±1
(30)
(95)
100±4
97±1
M±5%
Lead wire length (m)
2
(80)
85±10
* Ferrule Dimensions
Cross-sectional diameter: 2 mm max.
Length: 9 mm max.
Model
E52-P10GRF 2M
Waterproof Platinum Resistance Thermometers
Specifications
E52-P10GPF
Element wire
Pt100
Class
Class B
Protective tubing
material
SUS304
Conductor type
3-conductor system
Temperature range 0°C to 70°C (underwater)
−20°C to 70°C (in the air)
Lead wire
Vinyl-covered 3-conductor
cable with 6.1 dia.
12/0.18
−25°C to 60°C
Resistive pressure 10 kg/cm2 max.
Dimensions
Full-circled welding Sleeve
(SUS304)
SUS304
protective tubing
Shrinkable tube
Ferrule *
(Black)
Product label Marker tube White
20 dia.
Red (A)
Lead wire
A
7±0.2 dia.
White (B)
B
B
Black (B)
(30)
12
(80)
85±10
100±10
62
5
M±5%
Note: The lead wires are vinyl-covered, and cannot be used underwater.
Use the E52-P5AF-40 if waterproof lead wires are required for use underwater.
Refer to page 41 for details.
* Ferrule Dimensions
Cross-sectional diameter: 2 mm max.
Length: 9 mm max.
Lead wire length (m)
Model
2
E52-P10GPF 2M
4
E52-P10GPF 4M
40
E52 (Ferrule)
Corrosion-resistant Models with Fluororesin-covered
Protective Tubing (with Ferrule)
FEP-molded Models (Completely Waterproof)
Specifications
E52-P5AF-40
Element type
Pt100
Class
Class B
Protective tubing
material
Fluororesin (FEP) tube
(element / fluororesin
mold (FEP))
Conductor type
3-conductor system
Temperature range
−50°C to 180°C
Lead wire
Fluororesin (FEP)
cover (with outer
cover): −50°C to 180°C
Dimensions
Fused (completely waterproof)
FEP-covered tubing
6 +0.1
−0.5 dia.
Shrinkable tube
(Black)
Ferrule *
Product label
Marker tube
White
Lead wire
Red (A)
A
B
B
65 +4
−1
30±5
White (B)
White (B)
(80)
90±10
M±4%
Model
Lead wire length (m)
E52-P5AF-40 2M
2
E52-P5AF-40 4M
4
* Ferrule Dimensions
Cross-sectional diameter: 2 mm max.
Length: 9 mm max.
41
E52 (Ferrule)
Silicone-covered Lead Wires Models (with Ferrule)
■ Thermocouples
Exposed-lead Models with Screws
Specifications
Element type
K (CA)
Class
Class 2 (0.75)
Screw material
SUS304
Thermal contact
Grounded type
Temperature range
0°C to 300°C
Lead wire
Silicone-covered (0.1/30): 0°C to
150°C
Terminal shape
Ferrule
Note: Refer to the installation example for the E52-CA1DY.
E52-CA1DF-40
Dimensions
Sleeve
(Brass-nickel plating)
Movable ring (brass)
SUS304
screw
Top ring (Brass)
Protective spring
(SUS304)
8±0.05
dia.
120°
6.5 +0.05
dia.
0
* Ferrule Dimensions
Cross-sectional diameter: 1.5 mm max.
Length: 9 mm max.
Ferrule *
Yellow
Shrinkable tube (Blue)
Maker tube
Lead wire
Red (+)
+
Model
3.8±0.1
2.8
1±0.1
10
−
0.6 dia.
+0.3
0
13±1
E52-CA1DF-40 M6 1M M6 (P=1.0)
1
E52-CA1DF-40 M6 2M M6 (P=1.0)
2
80±10
E52-CA1DF-40 M6 4M M6 (P=1.0)
4
White (−)
(20)
A±0.3
Lead wire
length (m)
(70)
80±5
0
−0.5
Screw
pitch
M±1%
Thermocouples with Crimp Terminals
Specifications
Element type
K (CA)
Class
Class 2 (0.75)
Thermal contact
Grounded type
Temperature range
0°C to 200°C
Lead wire
Silicone-covered : 0°C to 150°C
Terminal shape
Ferrule
E52-CA1GTF-14
Dimensions
M4, round,
crimp terminal
(N1.25-4)
6.6
Ferrule *
Shrinkable tube (Blue)
Silicone
shrinkable tubing
Lead wire
7 dia. max.
Maker tube
Red (+)
Product label
+
Sensing point
−
4.3 dia.
15±5
Yellow
30±5
* Ferrule Dimensions
Cross-sectional diameter: 1.5 mm max.
Length: 9 mm max.
Model
White (−)
Lead wire length (m)
(80)
E52-CA1GTF-14 1M
1
90±10
E52-CA1GTF-14 2M
2
M±4%
Lead wire length (M): 1 or 2 m
42
E52 (Ferrule)
Accessories
Compression Fittings
Model Information
Model
Screw of part
Applicable
a
protective tubing
diameter
PT 1/8 D=1.0
R 1/8
1.0 dia.
PT 1/8 D=1.6
1.6 dia.
PT 1/8 D=3.2
3.2 dia.
PT 1/8 D=4.8
Dimension
b
c
d
Flat diameter
Part c
Part b
5
13
10
14
14
5
15
12
17
14
4.8 dia.
PT 1/4 D=3.2
R 1/4
3.2 dia.
PT 1/4 D=4.8
4.8 dia.
PT 1/4 D=6.4
6.4 dia.
PT 3/8 D=8
R 3/8
8 dia.
5
19
15
21
17
PT 1/2 D=10
R 1/2
10 dia.
15.1
8
19
22
19
M 12 D=4.8
M 12
4.8 dia.
5
15
12
17
14
Note: The Compression Fitting is not of airtight construction. Do not use the Compression Fitting for applications in which the exposure of the
sensing object will cause problems.
The compression fitting is a screw that adjusts and secures the insertion
length of Temperature Sensors with the above protective tubing diameters.
The material of the Compression Fitting is SUS304 with internal fixing beads
made of brass.
a
Sensor side
Head side
d
c
b
Source: JIS B 0203 (Unit: mm)
<R1/8, 1/4, R3/8>
Tighten using the retaining screw to
secure to the protective tubing.
Material
Protective tubing dia.
D
Main body
SUS304
Lock bead
Brass
Retaining screw
SUS304
<1/2>
Front ring
SUS316
Nut
SUS316
Nominal
thread
size
T.P.I.
Outer
(No. of diamethreads ter: d
/inch)
Root
diameter: d1
Standard
diameter
position a
(from
pipe
end)
Minimum
effective
screw
length:
f
R 1/8
28
9.728
9.147
8.566
3.97
±0.91
2.5
R 1/4
19
13.157
12.301
11.445
6.01
±1.34
3.7
R 3/8
19
16.662
15.806
14.950
6.35
±1.34
3.7
R 1/2
14
20.955
19.793
18.631
8.16
±1.81
5.0
a
f
Back ring
SUS316
Main body
SUS316
Effective
diameter: d2
Tapered thread
d d2
d1
Standard dia.
Loose Flanges
Model Information
Applicable protective
tubing diameter
Material: Aluminum
Model
3.2 dia.
MF-1 D=3.2
4.8 dia.
MF-1 D=4.8
6.4 dia.
MF-1 D=6.4
8 dia.
MF-1 D=8
10 dia.
MF-2 D=10
12 dia.
MF-2 D=12
15 dia.
MF-2 D=15
22 dia.
MF-2 D=22
Note: 1. Use the Loose Flange in atmospheric pressure. The Loose
Flange is not of airtight construction.
2. Use the Loose Flange at 400°C maximum.
3. Do not apply the Loose Flange to protective tubing
diameters other than the applicable ones.
MF-1
MF-2
120°
120°
Three, 5 dia.
Three, 6.5 dia.
36
54 dia.
21 dia.
D dia.
M4
31 dia.
D dia.
5
14
24
23 dia.
45 dia.
M6
6.6
35 dia.
70 dia.
43
E52 (Ferrule)
Compensating Conductors
The material of the Compensating Conductor is the same as or similar to that of the Thermocouple. Therefore, the Thermocouple can be connected
to the Compensating Conductor just as if the length of the Thermocouple is to be extended. A standard model for a temperature range between
−20°C and 70°C and two types of heat-resistive models for a temperature range between 0°C and 150°C are available.
Be sure to use the compensating conductor for the extension of the length of the thermocouple.
Model Information
Thermocouple
R
Heat
resistance
Exterior
Model
(Length)
1m
2m
4m
8m
Standard
Fully vinyl-covered (waterproof)
WPRG-N 1M
WPRG-N 2M
WPRG-N 4M
WPRG-N 8M
Heat resistive
Fully glass-wool-covered
WPRH-N 1M
WPRH-N 2M
WPRH-N 4M
WPRH-N 8M
Fully glass-wool-covered with external shield WPRH6-N 1M WPRH6-N 2M WPRH6-N 4M WPRH6-N 8M
of stainless steel
K (CA)
Standard
Fully vinyl-covered (waterproof)
WCAG-N 1M
WCAG-N 2M
WCAG-N 4M
WCAG-N 8M
Heat resistive
Fully glass-wool-covered
WCAH-N 1M
WCAH-N 2M
WCAH-N 4M
WCAH-N 8M
Fully glass-wool-covered with external shield WCAH6-N 1M WCAH6-N 2M WCAH6-N 4M WCAH6-N 8M
of stainless steel
J (IC)
Silicone-covered (See note 2.)
WCAG-40 1M WCAG-40 2M WCAG-40 4M WCAG-40 8M
Standard
Vinyl covered (waterproof)
WICG-N 1M
WICG-N 2M
WICG-N 4M
WICG-N 8M
Heat resistive
Fully glass-wool-covered
WICH-N 1M
WICH-N 2M
WICH-N 4M
WICH-N 8M
Fully glass-wool-covered with external shield WICH6-N 1M WICH6-N 2M WICH6-N 4M WICH6-N 8M
of stainless steel
Note: 1. Compensating Conductors with lengths, increased in units of a meter, up to 100 meters are available on request. Specify lengths above
100 meters in units of 100 meters. The maximum length depends on the product. Contact your OMRON representative for details.
2. It has the same waterproof characteristics as the standard model (fully vinyl-covered) and can be used at high temperatures.
Specifications (JIS C1610-1995)
Model
WPRG-N
Type of
thermocouple
R
WPRH-N
Use
Code
(See note.)
K (CA)
RCA-2-G
Fully vinyl-covered (waterproof) 7/0.3
0 to 90
±30
RCB-2-H
Fully glass-wool-covered
0 to 150
±60
±100
7/0.32
Exterior
color
Black
Standard
KCC-2-G
Fully vinyl-covered (waterproof) 7/0.3
0 to 90
Heat resistive
KCB-2-H
Fully glass-wool-covered
7/0.32
0 to 150
30/0.1
−20 to 150
±100
±140
Blue
Fully glass-wool-covered with
external shield of stainless steel
WCAG-40
WICH6-N
Error (°C)
Heat resistive
WCAH6-N
WICG-N
Operating
temperature
range (°C)
Fully glass-wool-covered with
external shield of stainless steel
WCAH-N
WICH-N
Number of
wires/wire
diameter
Standard
WPRH6-N
WCAG-N
Exterior
J (IC)
Heat resistive
KX-2-G
for moving parts
Silicone-covered
Standard
JX-2-G
Fully vinyl-covered (waterproof) 7/0.3
−20 to 90
Heat resistive
JX-2-H
Fully glass-wool-covered
0 to 150
7/0.32
Yellow
Fully glass-wool-covered with
external shield of stainless steel
Note: Symbols conform to JIS standards.
For code having duplicate exterior, check the application and check in our models.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
44
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2016.6
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation