AVX F0402G

Accu-Guard® II Low Current
Miniature 0402 Size Thin-Film Fuses
The new F0402G Accu-Guard® series of fuses is based on
thin-film technology which allows precise control of the
component electrical and physical characteristics that is not
possible with standard fuse technologies. The Accu-Guard
Low Current series encompasses the lowest current ratings
in a compact 0402 package and features LGA terminations.
ELECTRICAL SPECIFICATIONS
RECOMMEND PAD LAYOUT
Operating temperature: -55ºC to +125ºC
Current carrying capacity:
-55ºC to -11ºC 107% of rating
-10ºC to +60ºC 100% of rating
+61ºC to +100°C 85% of rating
+101ºC to +125°C 80% of rating
Rated voltage: 32V
Post-fusing resistance: >1MΩ
millimeters (inches)
0.55
(0.022)
0.31 (0.012)
1.15 (0.045)
Part Number
F0402G0R05FNTR
F0402G0R06FNTR
F0402G0R07FNTR
F0402G0R10FNTR
F0402G0R12FNTR
F0402G0R15FNTR
F0402G0R20FNTR
Current
Rating
A
0.050
0.062
0.075
0.100
0.125
0.150
0.200
Resistance
@0.1 x IRATED
Ω (max.)
3.4
2.5
2.0
2.4
1.6
1.2
0.8
Voltage Drop
@IRATED
mV (max.)
250
280
280
300
250
220
210
Fusing Current
(within 5 sec)
A
0.125
0.155
0.1875
0.250
0.312
0.375
0.500
Pre-Arc I2t
@10xIRATED
A2-sec (typ)
2 x 10-6
2 x 10-6
4 x 10-6
7 x 10-6
1 x 10-5
2 x 10-5
4 x 10-5
Color
Code
Blue
Yellow
Brown
Red
White
Green
Pink
ENVIRONMENTAL CHARACTERISTICS
Test
Solderability
Leach Resistance
Storage
Shear
Temperature
Cycling
Bend
Conditions
Components completely immersed in a
solder bath at 245 ±5°C for 3 secs.
Components completely immersed in a solder
bath at 255 ±5°C for 60 secs.
12 months minimum with components
stored in “as received” packaging.
Components mounted to a substrate.
Increasing shearing force applied paralled to
the sufstrate till destruction.
Components mounted to a flexible substrate
(e.g. FR – 4). 1000 cycles -55ºC to +125ºC.
Tested as shown in diagram
3 mm�
Deflection
45mm
45mm
Requirement
Total area of imperfections in solder coating
up to 5% of the land suface area
Dissolution of termination
≤ 15% of the land surface area
Good solderability
Destruction at 5N force minimum
No Visible damage
ΔR/R<10%
No visible damage
ΔR/R<10%
Accu-Guard® II Low Current
Miniature 0402 Size Thin-Film Fuses
FUSE TIME – CURRENT CHARACTERISTICS
10
200 mA
150 mA
1
125 mA
-1
10
Pre-Arc Time, Sec
100 mA
-2
10
75 mA
10-3
62 mA
10-4
50 mA
10-5
-6
10
0.1
1
Current, Amp
4
10
Accu-Guard® II Low Current
Miniature 0402 Size Thin-Film Fuses
FUSE PRE-ARC JOULE INTEGRALS VS CURRENT
10
200 mA
1
150 mA
125 mA
10 -1
Pre-Arc I2t, A2sec
100 mA
10 -2
75 mA
10 -3
62 mA
50 mA
10 -4
10 -5
10 -6
0
0.5
1
1.5
Current, Amp
2
2.5
3
Accu-Guard® II Low Current
Miniature 0402 Size Thin-Film Fuses
FUSE PRE-ARC JOULE INTEGRALS VS PRE-ARC TIME
10
1
Pre-Arc I2t, A2sec
200 mA
150 mA
125 mA
100 mA
75 mA
10 -1
10 -2
10 -3
10 -4
50 mA
62 mA
10 -5
10 -6
10 -6
10 -5
10 -4
10 -3
10 -2
Pre-Arc Time, seconds
6
10 -1
1
10