View detail for AT28C64B Reliability Qualification Report

PAGE 1 OF 8
ATMEL CORPORATION
Tel:(408)441-0311
Fax:(408)436-4200
AT-28C64B PEROM RELIABILITY DATA
-150°C OPERATING LIFE TEST
-200°C RETENTION BAKE
-CYCLE TEST
-125°C OPERATING LIFE TEST (PLASTIC)
-150°C RETENTION BAKE (PLASTIC)
-15 PSIG PRESSURE POT
-85°C/85% RELATIVE HUMIDITY OPERATING LIFE TEST
* This report was generated from AT-28C64B reliability testing.
This data is applicable to the following device types due to
same technology grouping as defined in MIL-M-38535 Appendix
A:
AT-28C256
AT-28HC64B
APRIL 2005
2325 Orchard Parkway San Jose CA. 95131
PAGE 2 OF 8
AT-28C64B
150°C DYNAMIC OPERATING LIFE TEST
LOT
NUMBER
DATE
CODE
SAMPLE
SIZE
TOTAL
CKT-HRS(K)
NUMBER
OF FAILURES
3B0910
3B9327
78
78.0
0
3C1449
3C9348
78
78.0
0
4A1345
4A9424
80
200.0
0
4C2051
4C9449
78
78.0
0
4D1708
4D9507
80
200.0
0
5A1542
5A9520
80
200.0
0
6L0014-1
6L9629
480
480.0
0
6C1822A
6C9646
200
200.0
0
6C2138
6C9641
80
80.0
0
6M0064-3
6M9652
80
80.0
0
6D1565-9
6D9702
80
80.0
0
6D1584
6D9704
579
579.0
0
6D1820-2
6D9705
80
80.0
0
6N8531
6N9708
80
80.0
0
FAILURE RATE
TOTAL DEVICE HOURS
BEST ESTIMATE
2,493,000 DEVICE HOURS
λ
= 0.03% PER 1,000 HOURS
λ
EXTRAPOLATION TO 50°C VIA ARRHENNIUS
EQUATION AND ACTIVATION ENERGY OF
0.5eV
= 0.0004% PER 1,000 HOURS (4 FITS)
50°C AMBIENT
CONFIDENCE ESTIMATE
λ
λ
60 = 0.0005% PER 1,000 HOURS
60% CONFIDENCE (5 FITS)
90 = 0.001% PER 1,000 HOURS
90% CONFIDENCE (13 FITS)
PAGE 3 OF 8
AT-28C64B
200°C DATA RETENTION BAKE
LOT
NUMBER
DATE
CODE
SAMPLE
SIZE
TOTAL
CKT-HRS(K)
NUMBER OF
OF FAILURES
3C1449
3C9348
78
78.0
0
4A1345
4A9424
80
80.0
0
4D1708
4D9507
80
80.0
0
5B0417
5B9531
80
80.0
0
5C1544
5C9539
79
79.0
0
5A1542
5A9520
79
79.0
0
6L0014-1
6L9629
79
79.0
0
E6C2138
6C9641
79
79.0
0
6D1565-9
6D9702
80
80.0
0
6D1584
6D9704
80
80.0
0
6D1820-2
6D9705
80
80.0
0
6N8531
6N9708
80
80.0
0
FAILURE RATE
TOTAL DEVICE HOURS
BEST ESTIMATE
954,000 DEVICE HOURS
λ
= 0.07% PER 1,000 HOURS
λ
EXTRAPOLATION TO 50°C VIA ARRHENNIUS
EQUATION AND ACTIVATION ENERGY OF
0.5eV
= 0.0003% PER 1,000 HOURS (3 FITS)
50°C AMBIENT
CONFIDENCE ESTIMATE
λ
λ
60 = 0.0003% PER 1,000 HOURS
60% CONFIDENCE (3 FITS)
90 = 0.0008% PER 1,000 HOURS
90% CONFIDENCE (8 FITS)
PAGE 4 OF 8
Data cycling followed by 200°C bakes were performed to determine
the
device endurance. Each address was byte cycled through all
addresses.
The parts were baked and then verified. The results of the cycling
tests are shown below. No device failures have been found.
CYCLE TEST RESULTS OF AT-28C64B
LOT
BAKE
NUMBER
TIME
DATE
SAMPLE
NO. OF
NO. OF
BAKE
CODE
SIZE
BYTE CYCLE
FAILURES
TEMP
3B0910
hrs
3B9327
80
10,000
0
200°C
176
3C1449
hrs
3C9348
78
10,000
0
200°C
176
4A1345
hrs
4A9424
80
10,000
0
200°C
176
4C2051
hrs
4C9449
78
10,000
0
200°C
176
4D1708
hrs
4D9507
80
10,000
0
200°C
176
5A1542
hrs
5A9520
80
100,000
0
200°C
176
PAGE 5 OF 8
AT-28C64B
PLASTIC PACKAGE
125°C DYNAMIC OPERATING LIFE TEST
LOT
DATE
SAMPLE
TOTAL
NUMBER
OF
NUMBER
FAILURES
CODE
PKG
SIZE
CKT-HRS(K)
OF
3B0910B1
3B9329
32 PLCC
75
75.0
0
4A2050
4A9422
32 PLCC
261
261.0
0
6L0014-3
6L9630
28 PDIP
198
198.0
0
7K5050
7K9734
28 TSOP
199
199.0
0
7A3015-1
7A9807
28 SOIC
100
100.0
0
8G3093-3
8G9837
28 PDIP
100
100.0
FAILURE RATE
TOTAL DEVICE HOURS
BEST ESTIMATE
933,000 DEVICE HOURS
λ
50°C AMBIENT
λ
CONFIDENCE ESTIMATE
λ
λ
= 0.07% PER 1,000 HOURS
EXTRAPOLATION TO 50°C VIA
ARRHENNIUS EQUATION AND
ACTIVATION ENERGY OF 0.5eV
= 0.003% PER 1,000 HOURS (25
FITS)
60 = 0.004% PER 1,000 HOURS
60% CONFIDENCE (33 FITS)
90 = 0.01% PER 1,000 HOURS
90% CONFIDENCE (84 FITS)
0
PAGE 6 OF 8
AT-28C64B
PLASTIC PACKAGE
150°C RETENTION BAKE
LOT
DATE
SAMPLE
TOTAL
NUMBER
OF
NUMBER
FAILURES
CODE
3B0910B1
3B9329
6L0014-3
PKG
SIZE
CKT-HRS(K)
OF
32 PLCC
77
77.0
0
6L9630
28 PDIP
128
128.0
0
7K5050
7K9734
28 TSOP
290
290.0
0
7A3015-1
7A9807
28 SOIC
100
100.0
0
8G3093-3
8G9837
28 PDIP
300
300.0
0
1E0610
1E0122
28 PDIP
50
50.0
0
FAILURE RATE
TOTAL DEVICE HOURS
BEST ESTIMATE
945,000 DEVICE HOURS
λ
50°C AMBIENT
λ
CONFIDENCE ESTIMATE
λ
λ
= 0.07% PER 1,000 HOURS
EXTRAPOLATION TO 50°C VIA
ARRHENNIUS EQUATION AND
ACTIVATION ENERGY OF 0.5eV
= 0.001% PER 1,000 HOURS (11
FITS)
60 = 0.001% PER 1,000 HOURS
60% CONFIDENCE (14 FITS)
90 = 0.004% PER 1,000 HOURS
90% CONFIDENCE (35 FITS)
PAGE 7 OF 8
AT-28C64B
PLASTIC PACKAGE
PRESSURE POT TEST
DATE
CODE
PKG
TYPE
SAMPLE
SIZE
NUMBER OF FAILURES
AT INDICATED HOURS
(24)
(48)
(72)
(96)
3B9329
32 PLCC
89
0
0
0
0
4D9508
28 SOIC
116
0
0
0
0
7K9734
28 TSOP
200
0
0
0
0
7A9807
28 SOIC
50
0
0
0
0
1E0122
28 PDIP
50
0
0
0
0
PAGE 8 OF 8
AT-28C64B
PLASTIC PACKAGE
85°C/85% RELATIVE HUMIDITY OPERATING LIFE TEST
LOT
NUMBER
HOURS
DATE
CODE
PACKAGE
TYPE
SAMPLE
SIZE
NUMBER OF FAILUES
AT INDICATED
(168)
(500)
(1000)
4D1364
4D9508
28 SOIC
45
0
0
7K5050
7K9734
28 TSOP
78
0
0
0
0