TECHNICAL DATA SHEET Membrane Target Systems™ Caution: For Laboratory Use. A research reagent for research purposes only human Serotonin 5-HT2B Receptor Product No.: ES-314-M400UA Lot No.: 1934474 Material Provided Membranes: 1 x 400 units / 400 µL frozen aliquot Product Information Cellular Background: CHO-K1 GenBank Accession Number: X77307 Unit Size: 7 µg protein / unit Storage Buffer: 50 mM Tris-HCL (pH 7.4), 0.5mM EDTA, 10mM MgCl2, 10% sucrose. Storage Conditions: Store at -80°C. Freeze-thaw is not recommended as it can affect product performance and homogeneity. In order to minimize negative impact of freeze-thawing, flash freeze in liquid o nitrogen for 30 seconds prior to transferring to -80 C. Stability: This product is stable for at least 3 years from reception if used and stored under recommended conditions. Quality Control Bmax and Kd are determined using radioactive saturation binding assays (Figure 1). Protein (1) concentration is determined using the BCA method . Ratio-to-Reference (RTR) is determined by dividing the maximal signal of the current lot (Bmax in fmoles) by the maximal signal of a pre-defined reference tested in parallel. RTR is an indicator of lot-to-lot consistency. *We certify that these results meet our quality release criteria. Ratio-to-Reference (RTR): 1.13 Expression Level (BMAX): 3.8 pmol/mg membrane protein. 3 KD for [ H]-LSD : 0.41 nM Protein Concentration: 7 µg/µL (1) Smith, P.K., et al. (1985). Anal. Biochem. 150, 76-85. TDS-ES-314-M400UA-04 Page 1 of 4 Recommended Assay Conditions Assay Buffer: 50 mM Tris pH 7.4, 4 mM CaCl2, 0.1% ascorbic acid Wash Buffer: 50 mM Tris-HCl pH 7.4 Binding Protocol: Binding assays are performed in 550 µL total volume according to the following conditions: 1 - Membrane dilution: 0.05 mL of membranes + 24.95 mL assay buffer (1:500 dilution) 2 - Incubation: 25 µL of incubation buffer or Serotonin (5-HT) (Sigma H9523) 50 µM final for non specific binding (Saturation binding assay) For competition binding assay: 25 µL of reference compounds at decreasing concentrations (see figure 2) 25 µL of radioligand at the appropriate concentration (see graph below) 500 µL of diluted membranes 3 - Incubation time: 30 minutes at 37 °C 4 - Filtration: aspirate and wash 9 x 500 µL with ice cold wash buffer over GF/C filter (presoaked in 0.5 % PEI). Lot Specific Data 4000 T o ta l N o n s p e c ific B o u n d (c p m ) 3000 S p e c ific 2000 1000 0 0 1 2 3 4 5 6 7 8 [3 H ]-L S D (n M ) Figure 1: Saturation binding assay curve (filtration) 96-well saturation binding assay curve (7 µg 3 membranes/well, TopCount®) using [ H]-LSD (PerkinElmer NET638 Lot No.: 1930614) TDS-ES-314-M400UA-04 Page 2 of 4 Typical Product Data Bound (cpm) 2000 Spiperone 1500 Yohimbine Ritanserin 1000 BW 723C86 500 0 - -13 -12 -11 -10 -9 -8 -7 -6 -5 -4 [Compound] (M) Figure 2: Competition binding assay curve (filtration) 96-well competition binding assay curve (7 µg membranes/well, TopCount®). Recommended radioligand concentration = 1 nM. *Even though two sites can be observed occasionally with some ligands, the data presented is derived from single site fitting. Reference Compounds Spiperone TDS-ES-314-M400UA-04 Page 3 of 4 Ki (nM) 813 Yohimbine 29 Ritanserin 0.60 BW 723C86 47 Suggested Materials and Instrumentation Please visit our website www.perkinelmer.com/GPCR This product is not for resale or distribution except by authorized distributors. When applicable, the CMV promoter is covered by U.S. Patents 5,168,062 and 5,385,839, licensed to PerkinElmer by the University of Iowa research Foundation LIMITED WARRANTY: PerkinElmer BioSignal Inc. warrants that, at the time of shipment, the products sold by it are free from defects in material and workmanship and conform to specifications which accompany the product. PerkinElmer BioSignal Inc. makes no other warranty, express or implied with respect to the products, including any warranty of merchantability or fitness for any particular purpose. Notification of any breach of warranty must be made within 60 days of receipt unless otherwise provided in writing by PerkinElmer BioSignal Inc. No claim shall be honored if the customer fails to notify PerkinElmer BioSignal Inc. within the period specified. The sole and exclusive remedy of the customer for any liability of PerkinElmer BioSignal Inc. of any kind including liability based upon warranty (express or implied whether contained herein or elsewhere), strict liability contract or otherwise is limited to the replacement of the goods or the refunds of the invoice price of goods. PerkinElmer BioSignal Inc. shall not in any case be liable for special, incidental or consequential damages of any kind. PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/ContactUs Copyright ©2009, PerkinElmer, Inc. All rights reserved. PerkinElmer ® is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners.