NCL30082FLYGEVB_TEST_PROCEDURE.PDF - 79.0 KB

Test Procedure for the NCL30082FLYGEVB Evaluation Board
Equipment Needed
AC Source – 100 to 265 V ac 50/60 Hz Minimum 1 A ac capabilities
AC Wattmeter – 30 W Minimum, True RMS Input Voltage and Current, Power Factor 0.2%
accuracy or better
DC Voltmeter – 100 V dc minimum 0.1% accuracy or better
DC Ammeter – 1 A dc minimum 0.1% accuracy or better
LED Load
Flyback – 14 – 17 V dc – 5 LED Load @ 500 mA
Buck Boost – 50 – 55 V dc – 15 LED Load @ 200 mA
Test Connections
1. Connect the Unit Under Test (UUT) per the test set up in Figure 9.
AC Power
Source
AC
Wattmeter
UUT
DC
Ammeter
DC
Voltmeter
LED Test
Load
Figure 9. Test Set Up
2. Set the AC source to 120 ±1 V ac RMS 60 Hz or 230 ±2 V ac RMS 50 Hz.
Note: Unless otherwise specified, all voltage measurements are taken at the terminals
of the UUT.
4/11/2013
-1-
www.onsemi.com
Functional Test Procedure
Flyback Version (NCL30082FLYGEVB)
Test Condition
Test Variable
Vin = 100 V ac
Vin = 120 V ac
Vin = 265 V ac
Vin = 265 V ac
Output Current
Output Current
Output Current
Power Factor
Efficiency (use
actual measured
data)
Vin = 120 V ac
Vout = 14 V
Test Limits
Min
Max
490 mA
510 mA
490 mA
510 mA
490 mA
510 mA
0.70
Pass/Fail
82 %
Buck Boost Version (NCL30082BB1GEVB)
Test Condition
Test Variable
Vin = 100 V ac
Vin = 120 V ac
Vin = 265 V ac
Vin = 265 V ac
Output Current
Output Current
Output Current
Power Factor
Efficiency (use
actual measured
data)
Vin = 120 V ac
Vout = 55 V
Test Limits
Min
Max
190 mA
200 mA
190 mA
200 mA
190 mA
200 mA
0.70
87 %
Efficiency =
4/11/2013
Pass/Fail
× 100%
-2-
www.onsemi.com