OE spec MTUContainer CHP 1 15 ES

POWER MODULE
MTU Series 4000
Gas Generator Sets
Optional equipment and finishing shown. Standard may vary.
Product Highlights
// Benefits
- High operational safety
- Plug & play solution, simple installation and "on-site"
operation
- Optimized overall efficiency of the container system
- Minimum external dimensions required
- Modular design
- Selectable optional packages enable flexible adaptation
to meet customer requirements
- Easy to service and maintain owing to proven access
point concepts
// MTU
Onsite Energy is a single-source supplier
// Global
product support
// Complete
range of accessories available
- Control panel
- Circuit breakers
- Fuel system
- Heat recovery system (JW and exhaust)
- Lube oil system
// Certifications
- EU machine directive 2006/42/EC
- Low voltage directive 2006/95/EC
- EMC directive 2004/108/EC
- GOST-R certificate
1
2
3
4
5
6
7
8
9
Description of individual components
1
2
3
4
5
Air inlet
Recooling systems for mixture cooling circuit
Generator power panel including
customer's connection
Emergency stop button
Accessdoor engineroom
6
7
8
9
Exhaust silencer
Exhaust gas heat exchanger w/ bypass
Recooling systems for jacket water cooling
circuit
Fuel gas inlet
Application data➀
// Engine
Manufacturer
Model
// MTU
MTU 8-20V4000 GS
Ratings
Operation mode:
Grid parallel
Rated power continuous power (3A): kWe
Voltage
400V 50 Hz
Fuel typesNatural Gas (NG)/ Non Natural Gas (NNG)
MTU 8V4000 GS
762 - 800
MTU 12V4000 GS
1151 - 1169
MTU 16V4000 GS
1534 - 1562
MTU 20V4000 GS
1924 - 2535
// Heat recovery & Cooling System
Temperature heat recovery w/o EGHE: °C
Temperature heat recovery w/ EGHE: °C
Emergency and mixture cooler design temperature: °C
// 70/80
70/90
35
Paint work
Engine, generator
Frame
Container
RAL9006
RAL5002
RAL7035
➀ Rated power refers to ISO standard conditions, 25°C ambient temperature and 100m above sea level.
STANDARD AND OPTIONAL FEATURES
// STANDARD SCOPE OF SUPPLY
■ Special container of sound-insulated steel structure design
■ 50 Hz genset (engine with generator mounted on
base frame)
■ Recooling systems for engine and mixture cooling circuit
■ Recovery of thermal energy from
engine cooling water and exhaust
// ■ Generator power panel including customer's connection
■ MMC (MTU Module Control) for system control, regulating
and diagnosis
■ Lube oil system
■ Separate switch board room
OPTIONAL SCOPE OF SUPPLY
Application for dusty ambient conditions
Application for cold ambient conditions (<-10°C)
Application for hot ambient conditions (>40°C)
Efficiency kit
Aircondition controll cabinets
Without ventilation flaps
Super silence kit
Weather-proof enclosure
Exhaus gas heat recovery
Customer circuit pump
Heat quantity meter
Gas compressor
Gas meter
Stainless steel exhaust line
Without EGHE bypass
Oxygen catalytic converter
Day tank (gravity driven)
Colors
Island mode
Island backup mode
External controller
Customer communication
Roof railing
Climbing aid
■ Represents standard features
 Represents optional features
Weights and dimensions
Outline drawing above is for reference only. Do not use for installation design. For unit-specific template drawings, please see our website.
Container series
C40+
C47+
Genset/Engine 1)
8V
12V
16V
20V
Application/Operation modeCHPCHPCHPCHP
Shipping weight (kg) 2)
31500
32500
37500
–
Operating weight (kg) 3)
39700
41500
48500
–
Dimensions (mm)
a
3200/10' 50''
3200/10' 50''
3200/10' 50''
3200/10' 50''
b
3200/10' 50''
3200/10' 50''
3200/10' 50''
3200/10' 50''
c
12192/40'
12192/40'
14200
14200
d
3010
3010
3510
3510
e
6020
6020
7020
7020
f
9030
9030
10530
10530
g
12192
12192
14200
14200
h
3600
3600
3600
3600
j
300
300
300
300
k 4)
13415
13415
15421
15421
Subject to change. | Edition 01/15 | ENC 2015-09.
1) 400V series, medium voltage (MS) upon request
2) without operating equipment/roof structures
3) with operating equipment/roof structures
4) greater overall dimensions must be taken into consideration with the application of certain options (e.g. super silence kit, dusty ambient conditions)
C/F = Consult Factory/MTU Onsite Energy Distributor
Materials and specifications subject to change without notice.
MTU Onsite Energy
Part of the Rolls-Royce Group
www.mtuonsiteenergy.com