TE SENSOR SOLUTIONS FOR HVACR SENSOR SOLUTIONS /// HVACR TE SENSOR SOLUTIONS FOR HVACR TE Connectivity (TE) is a global technology leader, providing connectivity and sensor solutions essential in today’s increasingly connected world. With the acquisition of Measurement Specialties (MEAS), a global designer and manufacturer of sensors and sensor-based systems, TE is one of the largest sensor companies in the world. Our broad portfolio of sensor technologies is designed for a wide range of applications. We collaborate with engineers to help transform concepts into creations—redefining what’s possible using intelligent, efficient and high-performing TE products and solutions proven in harsh environments. SENSOR SOLUTIONS • PRESSURE • TEMPERATURE • HUMIDITY • POSITION • VIBRATION • FLOW • MASS AIR FLOW • ULTRASONIC INNOVATION QUALITY STATEMENTS • ISO 13485 • ISO 14001 • ISO 9001 • Measuring Instruments Directive 2004/22/EC annex D • TS 16949 • UL/CSA SENSOR SOLUTIONS /// HVACR HVACR APPLICATION SOLUTIONS Alternative Energy and Solar Commercial Chillers Container Storage • Room air temperature • Flue temperature for efficiency • Outside air temperature to modulate damper • Water inlet and outlet for solar water heaters • Solar refrigerators • Inlet and outlet refrigerant temperature • Suction line temperature • Room and outside air temperature • Compressor high side and low side pressure • Room humidity • Variable volume valve position • Sump water level sensors • Evaporator inlet and outlet water temperature • Compressor gas temperature • Condenser inlet and outlet water temperature • Compressor motor temperature • Container air temperature • Outside air temperature • Evaporator line pressure • Condenser line pressure • Container humidity • Defrost control—humidity or temperature • Anti-sweat heater control—humidity Boiler Controls • Inlet and outlet water temperature • Level sensing • Outside air temperature for reset control • Heat and cooling rate for boiler mass • Boiler lead and lag timing temperature Building and Energy Management • Room air temperature for thermostats • Duct air temperature • Duct air pressure • Room air humidity • Outside air temperature • Mass air flow sensors Commercial Cooking Equipment • Non-contact temperature sensors for flame detection • Temperature sensors for monitoring • Vibration sensors for fan motors Compressors and Motors • • • • Motor winding temperature Compressor discharge Compressor suction temperature Compressor high side and low side pressure • Compressor oil pressure • Compressor staging—pressure • Vibration and acoustic sensors for machine health monitoring Electronic Expansion Valves • Expansion valve pressure • Expansion valve temperature Forced Air Furnaces • • • • Inlet and outlet air temperature Room and outside air temperature Room humidity Air inlet and outlet pressure PAGE 3 HVACR APPLICATION SOLUTIONS Heat Pumps • Cabinet entering and leaving air temperature • Compressor high side and low side pressure • Compressor discharge, compressor suction temperature • Entering and leaving hot water temperature • Load entering and leaving water temperature • Source entering and leaving water temperature • Water coil and air coil temperature Humidifiers and Dehumidifiers • Room air humidity • Water temperature for humidification HVACR Diagnostic Equipment • Digital manifold pressure • Temperature for superheat monitoring Ice Machines • Bin level sensor temperature • Discharge water temperature • Water inlet temperature SENSOR SOLUTIONS /// HVACR Packaged Terminal Air Conditioner (PTAC) and Small A/C • • • • Coil temperature Defrost termination temperature Room temperature Room humidity Pool Heater and Equipment • • • • Flue temperature Inlet and outlet water temperature Outside air temperature Pressure sensor for clogged filter monitoring Refrigerators • Dewpoint measurement for anti-sweat control • Compartment humidity for food conservation • Humidity monitoring for defrost control • Zone air temperature Refrigeration Controls • Compressor head pressure • Compressor high side and low side pressure • Defrost termination temperature • Inlet and outlet refrigerant temperature • Suction line temperature Underfloor Heating and Ice Melting • Floor temperature monitoring • Liquid temperature • Room air temperature VAV Systems and Air Handlers • • • • Damper position Differential pressure Fan pressure optimization Inlet and outlet air temperature Water Heater Refrigerated Beverage Dispensing • Cabinet air temperature • Condenser inlet and outlet temperature • Compressor discharge, compressor suction temperature • Compressor high side and low side pressure • Water flow sensor • Water inlet and outlet temperature Zone Controls • Air temperature • Damper position • Duct temperature TE SENSOR SOLUTIONS FOR HVACR PRESSURE SENSORS Transducers and Transmitters M7100, U7100 M5200, U5200, D5100 Package Automotive grade, stainless steel hermetic pressure ports and integral electrical connector Industrial stainless steel housing with a large selection of threaded fittings, electrical connectors, cable options and customized housings Type Gage, no vent gage (M7100) Gage, sealed gage, absolute (U7100) Gage (M5200) Gage, sealed gage, absolute(U5200), Differential wet-wet (D5100) Pressure Range 0 - 10 thru 0 - 689 bar / 0 - 150 thru 0 - 10K psi (M7100) 0 - 1 thru 0 - 10 bar / 0 - 15 thru 0 - 150 psi (U7100) 0 - 3 bar thru 0 - 2K bar / 0 - 50 psi thru 0 - 30K psi (M5200) 0 - 0.14 bar thru 0 - 700 bar / 0 - 2 psi thru 0 - 10K psi (U5200) 0 - 0.07 bar thru 0 - 34 bar / 0 - 1 psi thru 0 - 500 psi (D5100) Output/Span 0.5 - 4.5 VDC [Ratiometric output], 1 - 5 VDC [Regulated] (M7100) 0.5 - 4.5 VDC [Ratiometric output] (U7100) 0.5 - 4.5 VDC, 1 - 5 VDC, 0 - 5 VDC, 0 - 10 VDC, 4 - 20 mA Unique Features • 1% total error band (-20°C to 85°C) • Solid state reliability • Survives high vibration and immersion • Microfused technology (M7100) • UltraStable technology (U7100) • Copper tube for HVACR (M7100) • Microfused technology (M5200) • UltraStable technology (U5200, D5100) • High performance at a low cost • Solid state reliability • 1% total error band (-20°C to 85°C all possible errors combined) (M5200, D5100) • 0.75% total error band (-20°C to 85°C all possible errors combined) (U5200) • Line pressure max. 1000 psi (D5100) Accuracy ±0.25% FSO ±0.25% FSO (M5200, D5100), ±0.1% FSO (U5200) Operating Temp. -40°C to 125°C -40°C to 125°C Dimensions (mm) 26.7 x 26.7 x 50.0 M5200: 22.23 x 22.23 x 80.77 / U5200: 22.23 x 22.23 x 98.04 / D5100: 25.4 x 58.4 x 72.0 Typical Apps HVACR refrigeration controls, compressors, hydraulic, energy and water management HVACR controls, energy and water management, pumps, compressors, pneumatic equipment, filter blockage, pressurized tank level Agency Approvals CE [EMC], UL 508 CE [EMC] (M5200, D5100), CE [EMC], UL 508 (U5200) Board Mountable Digital Output Board Mountable Amplified Output Combination Module Digital Output MS4515DO, MS4525DO MS4515, MS4525 MS8607 Unique Features • 14-bit digital sensor • Pressure and temperature measurement • Single supply of 3.3 or 5.0 VDC • Top, side barbed or manifold O-ring port • J lead or thru hole pins • Ratiometric analog output sensor • Single supply of either 3.3 or 5.0 VDC • Top, side barbed or manifold O-ring port • J lead or thru hole pins • Optional gel coat Options Linearity/Absolute Accuracy Output / Span Gel coat, low power ±0.25% / ±1% TEB Gel coat 0.25% Non-linearity / 1% TEB • QFN package pressure, temperature and humidity sensor • High resolution module: 0.016 mbar, 0.04% RH, 0.01°C • Supply voltage: 1.5 to 3.6 V • Integrated pressure, humidity and temperature • Fully factory calibrated — ±2 mbar / ±0.03 psi, ±3.0% RH at 25°C, ±1.0°C 14-bit digital word SPI or I2C protocol 10% to 90% or 5% to 95% of supply Digital 24-bit I2C Type Gage, differential (MS4515) Gage, absolute, differential, compound (MS4525) 0 - 2, 4, 5, 10, 20, 30” H2O (MS4515) 0 - 0.07, 0.14, 0.35, 1, 2, 3, 10 bar / 0 - 1, 2, 5, 15, 30, 50, 150 psi (MS4525) 0.69 bar / 10 psi (MS4515) 3X range (MS4525) Absolute Operating Temp. Gage, differential (MS4515DO) Gage, absolute, differential, compound (MS4525DO) 0 - 2, 4, 5, 10, 20, 30" H2O (MS4515DO) 0 - 0.07, 0.14, 0.35, 1, 2, 3, 10 bar / 0 - 1, 2, 5, 15, 30, 50, 150 psi (MS4525DO) 0.69 bar / 10 psi (MS4515DO) 3X range (MS4525DO) -25°C to 125°C -25°C to 105°C -40°C to 85°C Dimensions (mm) 12.5 x 9.9 12.5 x 9.9 5x3x1 Typical Apps Air flow measurements, process control, leak detection Air flow measurements, process control, leak detection Energy management systems, thermostats, humidifiers, dehumidifiers, home automation Pressure Range Overpressure 10 – 2K mbar, 0 – 100% RH, -40°C to 85°C 6 bar / 87 psi PAGE 5 TE SENSOR SOLUTIONS FOR HVACR PRESSURE SENSORS Media Isolated Modules Digital Output 85BSD, 86BSD 89BSD Package • 13 mm diaphragm diameter with weldable or process fittings (85BSD) • 16 mm diaphragm diameter with O-ring mount (86BSD) • 9 mm diaphragm diameter • Threaded/weldable • Pressure and temperature read-out • Low power: 1 μA (Standby < 0.15 μA) Accuracy ±0.25% span ±0.3% span Output/Span Digital 14-bit I2C or SPI Digital 24-bit I2C Total Error Band ±1.0% FSO ±3.0% FSO Max Type Gage, absolute Absolute, sealed gage Pressure Range 0 - 0.35, 1, 2, 3, 7, 10, 14, 20 bar / 0 - 5, 15, 30, 50, 100, 150, 200, 300 psi (85BSD) 0 - 0.07, 0.14, 0.35, 1, 2, 3, 7, 10, 14, 20 bar / 0 - 1, 2, 5, 15, 30, 50, 100, 150, 200, 300 psi (86BSD) 0 - 6, 12, 18, 28, 30 bar / 0 - 87, 174, 261, 406, 435 psi Overpressure 2X 2X Operating Temp. -40°C to 125°C -40°C to 85°C Dimensions (mm) Ø 15.9 x 7.9 (85BSD), Ø 15.9 x 9.3 (86BSD) Ø 9.0 x 7.5 Typical Apps Level controls, tank level measurement, corrosive fluids and gas measurement systems, sealed systems, submersible depth monitoring Level controls, tank level measurement, corrosive fluids and gas measurement systems, sealed systems, manifold pressure measurement, dive computers Media Isolated Modules Analog Output Transducers and Transmitters Industrial U86B MSP100 Package Mountable with O-ring seal Small housing with O-ring and proprietary ‘snap-in’ feature that lowers the total installed cost and customized housings for OEM applications Type Sealed gage, absolute Gage Pressure Range 0 - 5, 10, 12, 13 bar / 0 - 50, 100, 150, 200 psi 0 - 7 bar thru 0 - 34 bar / 0 - 100 psi thru 0 - 500 psi Output/Span 0.5 - 4.5 VDC (Ratiometric output) 100 mV typical Unique Features • Amplified • Microfused technology • Low cost stainless steel isolated transducer • No threads needed for pressure connect • Highly customized for OEM application • Solid state reliability Accuracy ±0.5% span ±0.5% FSO Operating Temp. -7°C to 105°C 0°C to 55°C Dimensions (mm) Ø 15.82 x 13.6 Socket spacing: 31.75 12.7 x 24.38 x 20.32 Typical Apps Liquid level, liquid pressure Beverage dispensing systems, automation, HVACR controls, energy and water management, pumps, compressors, pneumatic equipment SENSOR SOLUTIONS /// HVACR TE SENSOR SOLUTIONS FOR HVACR TEMPERATURE SENSORS Sensor Assemblies Push-in Sensors Screw-in Sensors Refrigeration Molded Sensors Package Brass, copper or stainless steel closed-end tube Brass, copper or stainless steel housing with integrated connector PVC or TPE Type Epoxy potted element, miniature design Epoxy potted element, rigid sheath Overmolded Sensor Range • NTC • RTD: Pt, Ni • Thermocouple: Type J, K, T, E • NTC • RTD: Pt, Ni, Cu • Thermocouple: Type J, K, T, E • NTC • RTD: Pt Unique Features • High moisture resistant • Available with mounting tabs or clips • Moisture resistant • Different threads types • Connectors available • High moisture resistant Accuracy • NTC: Custom tolerances available • Pt RTD: Class AA, A, B according to IEC60751 • NTC: Custom tolerances available • Pt RTD: Class AA, A, B according to IEC60751 • NTC: Custom tolerances available • Pt RTD: Class AA, A, B according to IEC60751 Operating Temp. Varies: -50°C to 250°C Varies: -50°C to 250°C -40°C to 125°C Dimensions (mm) Case specific dimensions Custom lengths, diameters and threads available 8 x 30, 6.5 x 25, 6 x 50, 6 x 5 x 15 Typical Apps Boiler, liquid, evaporator, HVACR, industrial processes control, district heating/cooling, gear boxes Boiler, liquid, industrial processes control, district heating/cooling, immersion Industrial processes control Sensor Assemblies Boiler Sensors Air Temperature Sensors Pipe Mount Sensors Package Brass housing Flange mount, snap-in, ring terminal Copper or stainless steel housing Type • Screw • Epoxy potted element with rigid sheath or with snap-in ring and overmold • Overmolded • Epoxy potted Sensor Range • NTC • RTD: Pt, Ni, Cu • NTC • RTD: Pt • NTC Unique Features • Integrated connector • Moisture resistant • Different threads types • Connectors available • Easy mounting features • Moisture resistant designs • Fast response time • Excellent thermal tracking • Fast response time • Moisture resistant construction Accuracy • NTC: Custom tolerances available • Pt RTD: Class AA, A, B according to IEC60751 • NTC: Custom tolerances available • Pt RTD: Class A, B or custom • NTC: Custom tolerances available Operating Temp. Varies: -50°C to 250°C -40°C to 105°C or higher -40°C to 125°C Dimensions (mm) Custom lengths, diameters and threads available Varies by design Custom configurations available Typical Apps Boiler control, liquid, industrial processes control, district heating and cooling, immersion Cabinet air, leaving air, duct air, VAV air, inlet/outlet air, room air, outside air Industrial process, boiler control, refrigeration, food service, energy management, test equipment PAGE 7 TE SENSOR SOLUTIONS FOR HVACR TEMPERATURE SENSORS Sensor Assemblies Handy Box Sensors Motor Temperature Sensors Package Duct mount or metal housing with PVC sun shield with or without weatherproof box Epoxy case or plastic tube with PTFE extension leads Type Fully potted subassembly Epoxy potted element Sensor Range • NTC • RTD: Pt • NTC • RTD: Pt, Ni-Fe (Other options also avaialbe on request) Unique Features • Easy mounting features • Moisture resistant designs • Fast response time • Excellent thermal tracking • Very rugged design • Epoxy case design provides rigidity and electrical isolation • Withstand varnish and bake operations with hermetic motors • PTFE insulated lead wires for extended temp range Accuracy • NTC: Custom tolerances available • Pt RTD: Class A, B or custom • NTC: Custom tolerances available • Pt RTD: Class A, B or custom Operating Temp. -40°C to 105°C High temp. models also available -40°C to 175°C High temp. models also available Dimensions (mm) Varies by design Varies by design Typical Apps Residential and commercial building controls, energy management systems Hermetic motor winding, general purpose motor winding Sensing Elements—NTC, RTD Radial Leaded Thermistors Axial Thermistors Package Radial, beads DO-35 Wired component Type • NTC • Epoxy or glass coated • NTC • Glass coated • RTD thin film platinum deposited on ceramic substrate, glass coated • Tube outline available • Connection via radial leads Resistance Range 100 to 1M 5k to 100k 100, 1000 (Other values on request) Unique Features • Interchangeable • Moisture resistant • Stability • UL/CSA certified models available • Tight tolerance (±1%) • Max stability using high density (HD) chip • Hermetically sealed • Tinned and nickel plated leads • Long term stability • Interchangeability • Small dimensions • Short response time • High electrical insulation Accuracy 0.25% to 20% ±1% to ±3% Class T (F0.1), A (F0.15), B (F0.3) according to DIN EN 60751 Operating Temp. -55°C to 280°C -40°C to 300°C -50°C to 600°C (Standard) Down to -200 °C or up to 1000 °C (On request) Dimensions (mm) 0.4 to 4.9 2.0 x 4.0 body 2.0 x 2.3 x 1.1 (Standard) 1.2 x 4.0 x 1.1 (Standard) Other dimensions (On request) Typical Apps Environmental temperature, general purpose sensing element for HVACR applications Refrigeration including cabinet sensing and evaporator coil, fire detection units, air-conditioning systems, PCB temp sensing, general purpose sensing element for HVACR applications General purpose sensing element for HVACR applications (Element selection will depend upon many factors including accuracy, temperature range and mounting configuration) SENSOR SOLUTIONS /// HVACR Platinum Thin Film Sensors TE SENSOR SOLUTIONS FOR HVACR TEMPERATURE SENSORS Sensing Elements—Digital Output Thermopiles TSYS Series TSEV Single or multi pixel series Package QFN16, TDFN8 OEM-module Type I2C, SPI, PWM, SDM (Convertible to analog voltage) Single pixel or multi pixel thermopile module Temp. Range — Object temperature range 0°C to 300°C (Other temperature ranges available upon request) Unique Features • Low power • Small size • Calibrated and ready to use • 16 bit resolution • Calibrated, interfaces: I2C, SPI • Different field of views: 5° at 50%, 10° at 50%, 90° at 50%, others on request Accuracy Up to ±0.1°C at -5°C to 50°C Depends on temperature range, typical 1% full scale, max. accuracy 0.1°C Operating Temp. -40°C to 125°C Ambient temperature range: 0°C to 85°C Dimensions (mm) QFN16: 4 x 4 x 0.85 TDFN8: 2.5 x 2.5 x 0.75 35 x 25 x 13 to 31 Typical Apps Industrial control, replacement of precision RTDs, thermistors and NTCs, heating and cooling systems Contactless temperature measurement on moving parts, heated rolls, microwave oven, air conditioner HUMIDITY SENSORS HTU2X Series HTU3535PVBM/Wire HS1101LF HTG351xCH HTF3000LF Package DFN type Cost effective small size mini-module Through hole with side opening plastic cap Cost effective small size mini-module PCB for board to board Type Digital RH and temperature Analog or digital voltage RH and NTC temperature Capacitive humidity Analog voltage RH and NTC temperature Frequency output for RH, direct NTC for temperature Operating Range 0 to 100% RH 0 to 100% RH 0 to 100% RH 0 to 100% RH 0 to 100% RH Operating Temp -40°C to 125°C -40°C to 110°C -60°C to 140°C -40°C to 110°C -40°C to 85°C Unique Features • Low power consumption • Fast response time • I2C interface or PWM interface or SDM interface • PTFE filter (Optional) • Electronics fully protected (5 V) • Multiple connector choices • Based on HTU21 • Very robust and recognized component capable of withstanding most of the applications in the humidity world in very cost effective ways • Electronics fully protected with potting material (3.3 V or 5 V) • Multiple connector choices • Voltage supply from 3 to 8 VDC • Through hole or SMD • T and R available Calibration ±3% RH at 25°C (10 to 95% RH) ±0.3°C at 25°C ±3% RH at 55% RH; ±0.25°C at 25°C 180 pF, ±3 pF at 55% RH ±3% RH at 55% RH; ±0.25°C at 25°C ±3% RH at 55% RH ±0.25°C at 25°C Dimensions (mm) 3.0 x 3.0 x 1.0 27 x 11.9 x YY (Depending on the connector, from 6 to 10.8 mm length) 10 x 10 x 19 27 x 11.9 x 6.7 12.5 x 18.5 x 11.2 Typical Apps Building automation systems, thermostats, humidifiers, dehumidifiers Building automation systems, thermostats, humidifiers, dehumidifiers Building automation systems, thermostats, humidifiers, dehumidifiers Building automation systems, thermostats, humidifiers, dehumidifiers Building automation systems, thermostats, humidifiers, dehumidifiers PAGE 9 TE SENSOR SOLUTIONS FOR HVACR POSITION SENSORS KMA36 PCI-650 Series RVIT-Z Type • TSSOP • Magnetic rotary position sensor, angle sensor • Stainless steel • Linear position transducer, absolute • PCB for OEM volumes • Angular position transducer, inductive, absolute Linearity — ±1% ±0.5% Excitation — 12 to 28 VDC DC Voltage Range 360° angle 11, 40, 70, 85, 100mm Up to ±75° Unique Features • Low cost MR encoder for rotational and incremental measurements • ATEX certification • Vibration and shock resistant • 100 bar operation • Compatible with refrigerants (Incl. ammonia) and compressor oils • Absolute position Output Voltage 0 - 5 V, I2C, customer specific 4 to 20mA DC voltage, DC current, digital Resolution Typ. 0.1° Infinite Infinite Accuracy Typ. 0.3° — — Operating Temp -25°C to 85°C -40°C to 120°C -25°C to 85°C Dimensions (mm) TSSOP20: 6.5 x 6.4 x 1.2 — Custom Typical Apps Knobs, small robotics, angular and linear position, flap location, louver control Refrigerant compressor capacity control valves, refrigerant compressor oil systems Viscometers, valve position, robotics, HVACR vane position VIBRATION SENSORS DC and Piezoelectric Accelerometers 808/808M1 810M1 MiniSense 100 LDTC Family 8011/ 8021-AR/AP 8032-01 4020/4030 Package TO-8 Board level Piezo film elements with or without mass and pins Stainless steel Stainless steel Molded plastic Type Adhesive (Stud mount option) SMD Cantilever beam with vertical or horizontal pins Stud/through hole mount Stud mount Screw mount F.S. Range (g) ±10, 50 (808) ±4, 20 (808M1) ±25, 100 ±10 (Typical) ±5 to ±50 ±50 to ±500 ±2 Unique Features • Hermetically sealed • Case grounded design • Bandwidth to 8 kHz • Small size, low cost • Dynamic response • 6 kHz bandwidth • Very low cost • High sensitivity (1 V/g) • Ultra-low power (Self generating) • Industrial accelerometer • Case isolated, internal shielding • ±50, 20, 10, 5 g ranges • Industrial accelerometer • Case isolated, internal shielding • Low cost • Molded strain relief • Low cost • Biaxial, with triaxial option • DC response • Rugged construction Accuracy ±1.0% Non-linearity ±2.0% Non-linearity ±20.0% (typical) ±1.0% Non-linearity ±1.0% Non-linearity ±1.0% Non-linearity Operating Temp -50°C to 100°C -40°C to 70°C -40°C to 85°C -55°C to 100°C -40°C to 85°C Dimensions (mm) Ø 15.2 x 16.6 12.70 x 15.24 19.05 x 6.35 x 6.35 22.23 x 48.26 14.3 x 45.3 71.2 x 40.0 x 15.2 Typical Apps Machine monitoring, data loggers, embedded applications Data logging, impact detection Wake-up switch, load imbalance, impact sensing Industrial applications, machine monitoring Industrial applications, machine monitoring Structural monitoring SENSOR SOLUTIONS /// HVACR -40°C to 125°C TE SENSOR SOLUTIONS FOR HVACR FLOW SENSORS ULTRASONIC SENSORS Standard Contact Point Level FS-01 Package Noryl Type Flow switch Max Pressure 10 Bar at 20°C Operating Temp -30°C to 85°C Unique Features LL-01 Type Gap Unique Features • SPST reed switch • Normally open, close on flow • All 316L SS • Integral electronics • Miniature threads • Single machined • No adjustment for viscosity, density Input 6 - 24 VDC Dimensions (mm) 106 x 32 x 32 Output 1/2A contact Typical Apps For direction of liquid and gas flow, mains water control, power shower, central heating systems, circulation pump protection, cooling systems Pressure 250 psi Temperature 100°C Actuation point 0.25" Process Connection 1/4" NPT or 1/2" NPT Cable 12" Approvals CE Typical Apps Histology processors, compressors, chillers, coolant reservoirs MASS AIR FLOW SENSORS LMM-H03 LMM-H04 Package Hybrid Hybrid Type Hot film anemometer component Hot film anemometer component Range Bi-directional Uni-directional Operating Temp -40°C to 125°C -40°C to 125°C Unique Features • High sensitivity at low heater temperatures • Fast response time • True air temperature sensor • High sensitivity at low heater temperatures • Fast response time • True air temperature sensor Calibration / Accuracy Dependent on electronics Dependent on electronics Dimensions (mm) 23 x 10.15 x 1.1 24 x 10.15 x 1.1 Typical Apps Industrial gas flow Industrial gas flow PAGE 11 Alternative Energy and Solar Boiler Controls Building and Energy Management Cold Beverage Dispensing Commercial Chillers • • Commercial Cooking Equipment Compressors and Motors Container Storage Electronic Expansion Valves Forced Air Furnaces Heat Pumps • • • • • Humidifiers and Dehumidifiers HVACR Diagnostic Equipment Ice Machines PTAC and Small A/C Pool Heater and Equipment • • • • Refrigerators Refrigerated Beverage Control Refrigeration Controls • • Underfloor Heating and Ice Melting VAV Systems and Air Handlers • Water Heater Zone Controls • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Ultrasonic Mass Air Flow Flow Vibration Position Humidity Temperature Pressure PRODUCT AND APPLICATION MATRIX • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • te.com/hvacrsensorsolutions © 2015 TE Connectivity. All Rights Reserved. Microfused, UltraStable, Measurement Specialties, TE Connectivity, TE, and the TE connectivity (logo) are • • TE SENSOR SOLUTIONS For More Information Contact TE Connectivity trademarks of the TE Connectivity Ltd. family of companies. Other logos, product and company names mentioned herein may be trademarks of their respective owners. te.com/sensorsolutions-contact While TE has made every reasonable effort to ensure the accuracy of the information in this brochure, TE does not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this brochure are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE for the latest dimensions and design specifications. SS-TS-HV100 09/2015 SENSOR SOLUTIONS /// HVACR www.te.com www.meas-spec.com