© Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUT1010 (Liquid and Gas) ■ Overview ■ Application Liquid applications Custody transfer, allo- Upstream cation, line balance, interface/densitometer Terminals Check metering, Midstream Underground stortransmix metering, age, transmission, product identification compressor stations Refineries Process control, blending, tank measurement, ship loading and unloading 3 SITRANS FUT1010 is the latest ultrasonic flow meter from Siemens. Ideal for applications within the liquid and gas hydrocarbon industry capable of providing custody transfer accuracy. With the newly developed permanent TransLoc™ mounting system, the sensors are permanently mounted on the outside of the pipe, eliminating any contact with the medium. SITRANS FUT1010 is available in two different configurations; a version for liquid hydrocarbon applications and a version for precise gas measurement. Both versions are offered in pipe sizes ranging from 4 inch to 24 inch (DN 100 to DN 600) with flange ratings of ANSI Class 150/300/600 for liquid and 300/600 for gas. ■ Benefits Transportation Crude oil pipelines, LPG pipelines, multiple product pipelines, airport facilities, liquid terminals Downstream Petrochemical and processing plants Downstream Production wells, gathering, separation and dehydration Electric power generation, industrial use, gas processing plants ■ Design SITRANS FUT1010 is available in two different configurations, both featuring the TransLoc mounting system: • A version for liquid hydrocarbon applications • A version for precise gas measurement Transmitter SITRANS FUT1010 is available with two, three or four paths and IP65 (NEMA 4X) wall mount or IP66 (NEMA 7) wall mount explosionproof enclosures. Sensor • Calibrated performance that meets custody transfer accuracy • WideBeam® technology allows for precision flow measurement by reducing the meter's sensitivity to changes in the medium's physical properties • TransLoc™ permanent mounting system ensures sealing and virtually no maintenance • Available in a wide range of sizes • High viscosity range (up to 2800 Cst) • ZeroMatic Path™ capability automatically corrects for zero drift with no interruption of flow • Completely cavity free design which eliminates any signal degrading buildup or ports to clog • Large bi-directional flow range • Modbus RTU RS 232/485 output available • Dynamic Reynolds Number compensation 3/376 Gas applications Pipelines Siemens FI 01 · 2016 Available sizes include 4 to 24 inch (DN 100 to DN 600) with flange ratings of ANSI Class 150, 300 and 600 for the liquid meter and ANSI Class 300 and 600 for gas. If the installation warrants, SITRANS FUT1010 can be delivered with a ten diameter upstream and five diameter downstream tubes and a flow conditioner. ■ Function • IP65 (NEMA 4X) and IP66 (NEMA 7) transmitters have integral 33 button keypads and large (128 x 240 pixel) graphic displays readable up to 12 m (40 ft) away • Current, voltage, status alarm, frequency and RS 232 outputs (see specification section for details) • Analog inputs (see specification section for details) • 1 MByte data logger with both site and data logger storage • Standard or actual volume flow outputs • Standard or actual totalize outputs • Complete application and operation diagnostics, to ensure operational integrity • Temperature provided by non-intrusive sensor (¾" tap available for insert temperature sensor) • Detection of aeration or contamination © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUT1010 (Liquid and Gas) ■ Technical specifications Design Flow sensor Input Flow range (Gas) Flow range (Liquid) Flow sensitivity ± 36.5 m/s (± 120 f/s) for DN 100 ... DN 200 (4" ... 8") pipes bi-directional ± 30.5 m/s (± 100 ft/s) for DN 250 ... DN 600 (10" ... 24") pipes bi-directional ± 12 m/s (± 40 f/s) including zero flow, bi-directional 0.0003 m/s (0.001 f/s) flow rate independent Flow temperature range -28 ... +93 °C (-20 ... +200°F) Analog inputs 4 x 4 ... 20 mA, (Programmable to Density, Pressure, viscosity or Temperature) Status/Alarm I/O 4" ... 24" (DN 100 ... DN 600) API 5L ERW Temperature tap ¾" Pressure tap ¼" Flange class • Liquid 150, 300, 600 • Gas 300, 600 Flange specification • ASME B16.5 • Liquid 150, 300, 600 • Gas 300, 600 Flange facing Raised face weld neck Flange material A105 Flow sensor paths Two, three, or four Sensor length See diagram Design temperature -28 ... +93 °C (-20 ... +200 °F) Exterior finish Marine/offshore grade per ASTM B117 Optional pipe sections • 10 D upstream (with optional flow conditioner) • 5 D downstream • Programmable, 4x Form C Relays • Clear Switch Input Totalizer Hold Switch Input FM and CSA • Transmitter N-I Class I, Div 2 S Class II, Div 2 • Sensor I.S. Class I, II, Div 1 ATEX Ex II (1) G [Ex ia] IIC EX II 3 (1) G Ex nC [ia] IIC T5 CE markings EMC 2014/30/EU ATEX 2014/34/EU Certificates and approvals Flow transmitter IP65 (NEMA 4X) Calibrated accuracy Gas 2-path 0.5 ... 1.0 % (4” ... 6” < 0.25 %) 3-path < 0.5 % 4-path < 0.2 % Flow Transmitter - IP66 (NEMA 7) Liquid 2-path 0.5 ... 1.0 % (4” ... 6” < 0.15 %) 3-path < 0.5 % 4-path < 0.15 % Repeatability ± 0.05 ... 0.1 % Data refresh rate 5 Hz Design FM and CSA • Transmitter Ex Class I, Div 1 D-I Class II, Div 1 N-I Class I, Div 2 S Class II, Div 2 • Sensor I.S. Class I, II, Div 1 ATEX Ex II (1) G [Ex ia] IIC Ex II 3 (1) G Ex nC [ia] IIC T5 Ex II 2 (1) G Ex d [ia IIC] IIB + H2 T5 CE markings EMC 2014/30/EU ATEX 2014/34/EU Design Flow transmitter Dimensions see SITRANS F US Clamp-on "System info and selection guide" Weight see diagrams Power supply Power supply 3 • 4x isolated 4 ... 20 mA, programmable • 2x 0 ... 10 V DC, programmable • 4x Digital Pulse outputs (2x open collector and 2x 0-5V TTL) One each for positive flow, one each for negative flow • Standard VT100 RS 232, Optional HART, BACnet MSTP/BACnet IP, Modbus RTU & TCP/IP, Ethernet IP, Johnson N2 Output Standard outputs Nominal pipe sizes Pipe material specification Sensor 90 ... 240 V AC, 50 … 60 Hz, 30 VA or 9 ... 36 V DC, 12 W Indication and operation Data logger memory 1 MByte, programmable for all available data variables Display 128 x 240 pixel LCD with backlight Keypad 33 keypad buttons with tactile feedback Language options English, Spanish, German, Italian, French FM and CSA I.S. Class I, Div 1 N-I Class I, Div 2 S Class II, Div 2 ATEX Ex II 1 G Ex ia IIC T5 CE markings EMC 2014/30/EU PED 97/23/EEC ATEX 2014/34/EU Siemens FI 01 · 2016 3/377 © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUT1010 (Liquid and Gas) ■ Dimensional drawings Sensor Upstream tube optional Siemens OD Downstream tube optional ID WT L2 3 L1 L3 L4 Length Liquid Flange Class 150 Nominal O.D. Nominal I.D. Max operating pressure (psi) Mat. Grade Length L1 Length L2 Length L3 Length L4 mm inch mm inch mm inch bar psi 101.6 4.0 114.3 4.5 102.3 4.026 19.7 285.0 B mm 1828.8 72.0 mm 1023.6 40.3 mm inch mm inch 510.5 20.1 3369.3 152.4 6.0 168.3 6.625 154.1 6.065 19.7 285.0 B 1828.8 72.0 132.65 1541.8 60.7 769.6 30.3 4146.6 203.2 8.0 219.1 8.625 202.7 7.981 19.7 285.0 B 163.25 1828.8 72.0 2026.9 79.8 1013.5 39.9 4875.5 254.0 10.0 273.1 10.75 254.5 10.02 19.7 285.0 191.95 B 2184.4 86.0 2545.1 100.2 1272.5 50.1 6008.4 304.8 12.0 323.9 12.75 304.8 12.0 19.7 236.55 285.0 B 2184.4 86.0 3048.0 120.0 1524.0 60.0 6762.8 406.4 16.0 406.4 16.0 387.4 15.25 266.25 19.7 285.0 B 2184.4 86.0 3873.5 152.5 1938.0 76.3 8002.3 457.2 18.0 457.2 18.0 438.2 315.05 17.25 19.7 285.0 B 2501.9 98.5 4381.5 172.5 2192.0 86.3 9081.8 508.0 20.0 508.0 20.0 357.55 489.0 19.25 19.7 285.0 B 2501.9 98.5 4889.5 192.5 2446.0 96.3 9843.8 609.6 24.0 609.6 24.0 387.55 590.6 23.25 19.7 285.0 B 2501.9 98.5 5905.5 232.5 2954.0 116.3 11367.8 447.55 Mat. Grade Length L1 Length L2 Length L3 Length L4 mm mm inch inch Length Liquid Flange Class 300 Nominal O.D. Nominal I.D. Max operating pressure (psi) mm inch mm inch mm inch bar psi mm inch mm inch 101.6 4.0 114.3 4.5 102.3 4.026 51.0 740.0 B 1828.8 72.0 1023.6 40.3 510.5 20.1 3369.3 132.65 152.4 6.0 168.3 6.625 154.1 6.065 51.0 740.0 B 1828.8 72.0 1541.8 60.7 769.6 30.3 4146.6 163.25 203.2 8.0 219.1 8.625 202.7 7.981 51.0 740.0 B 1828.8 72.0 2026.9 79.8 1013.5 39.9 4875.5 191.95 254.0 10.0 273.1 10.75 254.5 10.020 51.0 740.0 B 2184.4 86.0 2544.1 100.2 1272.5 50.1 6008.4 236.55 304.8 12.0 323.9 12.75 304.8 12.0 51.0 740.0 B 2184.4 86.0 3048.0 120.0 1524.0 60.0 6762.8 266.25 406.4 16.0 406.4 16.0 381.0 15.0 51.0 740.0 B 2184.4 86.0 3810.0 150.0 1905.0 75.0 7905.8 311.25 457.2 18.0 457.2 18.0 428.7 16.876 51.0 740.0 B 2501.9 98.5 4287.5 168.8 2143.8 84.4 8939.5 351.95 508.0 20.0 508.0 20.0 477.9 18.814 51.0 740.0 X42 2501.9 98.5 4777.7 188.1 2390.1 94.1 9676.1 380.95 609.6 24.0 609.6 24.0 574.7 22.626 51.0 740.0 X42 2501.9 98.5 5748.0 226.3 2872.7 113.1 11129.0 438.15 Mat. Grade Length L1 Length L2 Length L3 Length L4 mm inch inch Length Liquid Flange Class 600 Nominal O.D. Nominal I.D. Max operating pressure (psi) mm inch mm inch mm inch bar psi mm mm inch mm inch 101.6 4.0 114.3 4.5 102.3 4.026 96.6 1400.0 B 1828.8 72.0 1023.6 40.3 510.5 20.1 3369.3 132.65 152.4 6.0 168.3 6.625 154.1 6.065 81.0 1175.0 B 1828.8 72.0 1541.8 60.7 769.6 30.3 4146.6 163.25 203.2 8.0 219.1 8.625 193.7 7.625 102.1 1480.0 B 1828.8 72.0 1938.0 76.3 967.7 38.1 4740.9 186.65 254.0 10.0 273.1 10.75 247.7 9.75 82.8 1200.0 B 2184.4 86.0 2476.5 97.5 1239.5 48.8 5906.8 232.55 304.8 12.0 323.9 12.75 298.5 11.75 79.3 1150.0 B 2184.4 86.0 2984.5 117.5 1493.5 58.8 6668.8 262.55 406.4 16.0 406.4 16.0 373.1 14.688 82.8 1200.0 B 2184.4 86.0 3731.3 146.9 1864.4 73.4 7786.4 306.55 457.2 18.0 457.2 18.0 419.1 16.5 1250.0 B 2501.9 98.5 4191.0 165.0 2095.5 82.5 8794.8 346.25 508.0 20.0 508.0 20.0 466.8 18.376 82.8 1200.0 X42 2501.9 98.5 4668.5 183.8 2334.3 91.9 9511.0 374.45 609.6 24.0 609.6 24.0 560.4 22.064 77.6 1125.0 X42 2501.9 98.5 5603.2 220.6 2801.6 110.3 10913.1 429.65 3/378 Siemens FI 01 · 2016 86.2 inch inch © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUT1010 (Liquid and Gas) Length Gas Class 300 Nominal O.D. Nominal I.D. Max operating pressure (psi) Mat. Grade Length L1 Length L2 Length L3 Length L4 mm inch mm inch mm inch bar psi mm mm mm inch mm inch 101.6 4.0 114.3 4.5 102.3 4.026 51.0 740.0 B 1828.8 72.0 152.4 6.0 168.3 6.625 154.1 6.065 51.0 740.0 B 1828.8 72.0 1023.6 40.3 510.5 20.1 3369.3 132.65 1541.8 60.7 769.6 30.3 4146.6 203.2 8.0 219.1 8.625 202.7 7.981 51.0 740.0 X42 163.25 1828.8 72.0 2026.9 79.8 1013.5 39.9 4875.5 254.0 10.0 273.1 10.75 254.5 10.020 51.0 740.0 191.95 X42 1828.8 72.0 2545.1 100.2 1272.5 50.1 5652.8 304.8 12.0 323.9 12.75 303.2 11.938 51.0 222.55 740.0 X42 1828.8 72.0 3032.8 119.4 1516.4 59.7 6384.3 406.4 16.0 406.4 16.0 381.0 15.0 251.35 51.0 740.0 X42 1981.2 78.0 3810.0 150.0 1905.0 75.0 7702.6 303.25 457.2 18.0 457.2 18.0 428.7 16.876 51.0 740.0 X42 1981.2 78.0 4287.5 168.8 2143.8 84.4 8418.8 331.45 508.0 20.0 508.0 609.6 24.0 609.6 20.0 477.9 18.814 51.0 740.0 B 1981.2 78.0 4777.7 188.1 2390.1 94.1 9155.4 360.45 24.0 574.7 22.626 51.0 740.0 B 1981.2 78.0 5748.0 226.3 2872.7 113.1 10608.3 417.65 Mat. Grade Length L1 Length L2 Length L3 Length L4 mm mm inch mm inch inch inch Length Gas Class 600 Nominal O.D. Nominal I.D. Max operating pressure (psi) mm inch mm inch mm inch bar psi mm 101.6 4.0 114.3 4.5 102.3 4.026 102.1 1480.0 X42 1828.8 72.0 1023.6 40.3 510.5 20.1 3369.3 132.65 152.4 6.0 168.3 6.625 154.1 6.065 96.6 1400.0 X42 1828.8 72.0 1541.8 60.7 769.9 30.3 4146.6 163.25 203.2 8.0 219.1 8.625 202.7 7.981 87.9 1275.0 X42 1828.8 72.0 2026.9 79.8 1013.5 39.9 4875.5 191.95 254.0 10.0 273.1 10.75 247.7 9.75 102.1 1480.0 X42 1981.2 78.0 2476.5 97.5 1239.5 48.8 5703.6 224.55 304.8 12.0 323.9 12.75 298.5 11.75 94.8 1375.0 X42 1981.2 78.0 2984.5 117.5 1493.5 58.8 6465.6 254.55 406.4 16.0 406.4 16.0 381.0 15.0 75.9 1100.0 X42 1981.2 78.0 3810.0 150.0 1905.0 75.0 7702.6 303.25 457.2 18.0 457.2 18.0 428.7 16.876 75.9 1100.0 X42 1981.2 78.0 4287.5 168.8 2143.8 84.4 8418.8 331.45 508.0 20.0 508.0 20.0 477.9 18.814 75.9 1100.0 X42 1981.2 78.0 4777.7 188.1 2390.1 94.1 9155.4 360.45 609.6 24.0 609.6 24.0 574.7 22.626 72.4 1050.0 X42 1981.2 78.0 5748.0 226.3 2872.7 113.1 10608.3 417.65 inch inch Siemens FI 01 · 2016 3/379 3 © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUT1010 (Liquid and Gas) SITRANS FUT1010 Liquid sizing chart 3 Nominal diameter Qmin Qmax Qmin Qmax mm inch [m3/h] [m3/h] [42 GAL BBL/h] [42 GAL BBL/h] 100 4 14 360 85 2267 150 6 29 818 180 5146 200 8 46 1417 290 8910 250 10 67 2233 421 14045 300 12 80 3203 504 20143 400 16 103 5172 651 32532 450 18 116 6618 728 41625 500 20 124 8241 778 51836 600 24 150 12022 945 75617 SITRANS FUT1010 Gas sizing chart SITRANS FUT1010 maximum flow rate (MMSCFD) [Millions of standard cubic feet per day] Meter size and maximum velocity 4" 6" 8" 10" 12" 16" 20" 24" Pressure (psig) 135 ft/s 126 ft/s 117 ft/s 144 ft/s 126 ft/s 99 ft/s 81 ft/s 90 ft/s 100 8.2 17.3 27.9 54.1 67.1 83.3 107.1 174.9 200 15.5 32.9 52.9 102.7 127.6 158.2 203.4 332.3 300 23.1 49.0 78.7 152.8 189.8 235.4 302.6 494.5 400 30.9 65.5 105.3 204.4 253.9 315.0 404.8 661.5 500 39.0 82.6 132.8 257.6 320.0 396.9 510.1 833.6 600 47.3 100.1 161.0 312.4 388.0 481.2 618.5 1010.8 700 55.8 118.2 190.0 368.7 457.9 568.1 730.1 1193.1 800 64.6 136.8 219.8 426.6 529.9 657.3 844.8 1380.5 900 73.6 155.8 250.5 486.1 603.8 749.0 962.6 1573.1 1000 82.8 175.4 282.0 547.2 679.6 843.0 1083.5 1770.6 1100 92.3 195.4 314.1 609.6 757.1 939.2 1207.1 1972.7 1200 101.9 215.9 347.0 673.3 836.3 1037.4 1333.3 2178.9 SITRANS FUT1010 maximum flow rate (MMSCFD) [Millions of standard cubic feet per day] Meter size and maximum velocity [Minimum flow rate above which 0.2 % accuracy can be maintained] 4" 6" 8" 10" 12" 16" 20" 24" Pressure (psig) 1.55 ft/s 1.4 ft/s 1.3 ft/s 1.65 ft/s 1.35 ft/s 1.1 ft/s 0.85 ft/s 1 ft/s 100 0.1 0.2 0.3 0.6 0.7 0.9 1.1 1.9 200 0.2 0.4 0.6 1.2 1.4 1.8 2.1 3.7 300 0.3 0.5 0.9 1.8 2.0 2.6 3.2 5.5 400 0.4 0.7 1.2 2.3 2.7 3.5 4.2 7.4 500 0.4 0.9 1.5 3.0 3.4 4.4 5.4 9.3 600 0.5 1.1 1.8 3.6 4.2 5.3 6.5 11.2 700 0.6 1.3 2.1 4.2 4.9 6.3 7.7 13.3 800 0.7 1.5 2.4 4.9 5.7 7.3 8.9 15.3 900 0.8 1.7 2.8 5.6 6.5 8.3 10.1 17.5 1000 1.0 1.9 3.1 6.3 7.3 9.4 11.4 19.7 1100 1.1 2.2 3.5 7.0 8.1 10.4 12.7 21.9 1200 1.2 2.4 3.9 7.7 9.0 11.5 14.0 24.2 3/380 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUT1010 (Liquid and Gas) SITRANS FUT1010 Maximum Flow Rate (Nm3/h x 1000) [Thousands of normal cubic meters per hour] DIN meter size and maximum velocity 100 mm 150 mm 200 mm 250 mm 300 mm 400 mm 500 mm 600 mm Pressure (barg) 41.1 m/s 38.4 m/s 35.6 m/s 43.9 m/s 38.4 m/s 30.1 m/s 24.6 m/s 27.4 m/s 10 13.5 28.7 46.1 89.5 111.2 137.9 177.2 289.6 20 26.4 55.9 89.9 174.5 216.7 268.8 345.5 564.6 30 39.8 84.4 135.6 263.2 326.9 405.5 521.2 851.8 40 53.9 114.1 183.4 355.8 441.9 548.2 704.6 1151.4 50 68.5 145.0 233.1 452.4 561.9 697.0 895.9 1464.0 60 83.7 177.2 284.9 552.9 686.7 851.9 1094.8 1789.2 70 99.5 210.7 338.7 657.2 816.3 1012.6 1301.5 2126.9 80 115.8 245.3 394.3 765.1 950.2 1178.7 1514.9 2475.8 90 132.6 280.8 451.4 875.9 1087.8 1349.4 1734.3 2834.3 100 149.7 317.1 509.7 989.1 1228.5 1523.9 1958.6 3200.8 110 167.1 353.8 568.8 1103.8 1370.9 1700.6 2185.7 3571.9 120 184.5 390.8 628.2 1218.9 1514.0 1878.0 2413.7 3944.5 3 SITRANS FUT1010 Transition Flow Rate (Nm3/h x 1000) [Thousands of normal cubic meters per hour] DIN meter size and maximum velocity Minimum flow rate above which 0.2 % accuracy can be maintained 100 mm 150 mm 200 mm 250 mm 300 mm 400 mm 500 mm 600 mm Pressure (barg) 0.47 m/s 0.42 m/s 0.39 m/s 0.50 m/s 0.41 m/s 0.33 m/s 0.25 m/s 0.30 m/s 10 0.2 0.3 0.5 1.0 1.2 1.5 1.9 3.2 20 0.3 0.6 1.0 2.0 2.3 3.0 3.6 6.3 30 0.5 0.9 1.5 3.0 3.5 4.5 5.5 9.5 40 0.6 1.3 2.0 4.1 4.7 6.1 7.4 12.8 50 0.8 1.6 2.6 5.2 6.0 7.7 9.4 16.3 60 1.0 2.0 3.2 6.3 7.4 9.5 11.5 19.9 70 1.1 2.3 3.8 7.5 8.7 11.3 13.7 23.6 80 1.3 2.7 4.4 8.8 10.2 13.1 15.9 27.5 90 1.5 3.1 5.0 10.0 11.7 15.0 18.2 31.5 100 1.7 3.5 5.7 11.3 13.2 16.9 20.6 35.6 110 1.9 3.9 6.3 12.6 14.7 18.9 22.9 39.7 120 2.1 4.3 7.0 14.0 16.2 20.9 25.3 43.8 Siemens FI 01 · 2016 3/381 © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUT1010 (Liquid and Gas) Selection and Ordering data SITRANS FUT1010 (Liquid) Article No. Order Code 7 ME3 6 2 7 - 7 7 77 7 - 0 7 7 7 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. 3 Transmitter type No Transmitter IP65 NEMA 4X (2 path) IP65 NEMA 4X (2 path) with optional communications IP65 NEMA 4X (3 or 4 path) IP65 NEMA 4X (3 or 4 path) with optional communications IP66 NEMA 7 wall mount/explosionproof (2 Path) P66 NEMA 7 wall mount/explosionproof (2 Path) with optional communications P66 NEMA 7 wall mount/explosionproof (3 or 4 Path) P66 NEMA 7 wall mount/explosionproof (3 or 4 Path) Iwith optional communications Input power 90 ... 240 V AC 9 ... 36 V DC Number of ultrasonic paths 2 path 3 path 4 path Pipe size DN 100 (4") (Dual Path only) DN 150 (6")(Dual Path only) DN 200 (8") DN 250 (10") DN 300 (12") DN 400 (16") DN 450 (18") DN 500 (20") DN 600 (24") Flange rating Class 150 (Raised Face) Class 300 (Raised Face) Class 600 (Raised Face) Upstream/downstream meter run None 10 pipe diameter upstream Tube only 10 pipe diameter upstream Tube with flow conditioner 5 pipe diameter downstream tube only 10D up and 5D downstream tubes 10D up and 5D downstream tubes with flow conditioner Liquid type range (select closest match) Water Multiple Crude Oils Light Crude only Heavy Crude only Multiple Finished Products Gasolines Only Kerosene Jet Fuel Diesel Multiple Fuel Oils Heavy Fuel Oils Liquified Gases Liquid temperature range -28 ... +65 °C (-20 ... +150 °F ) 1 ... 93 °C (30 ... 200 °F) Transmitter and sensor approval FM/CSA, CE ATEX and PED, CE, C-TICK 3/382 Siemens FI 01 · 2016 0 1 2 3 4 5 6 7 8 1 2 B C D A B C D E F G H J 0 1 2 0 1 2 3 4 5 A B C D E F G H J K L M A B 1 2 777 © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUT1010 (Liquid and Gas) Order code Selection and Ordering data Further designs Please add "-Z" to Article No. and specify Order code(s). Cable assembly for flow sensor (add one K.. per flow path) • Cable and termination for one sensor path (see "Sensor cable chart for options") K.. • Termination for user supplied cable T01 Cable assembly for temperature sensor (only 1 required) • Cable and termination for temperature sensor (see "Transducer cable chart for options"). R.. • Termination for user supplied RTD cable T31 • Cable gland kit T51 3 Nace Certification • Nace, Spool only C10 • Nace, W/10D upstream C11 • Nace, W/10D upstream, cond C12 • Nace, W/5D downstream C13 • Nace, W/10D up, 5D dn C14 • Nace, W/10D up, cond, 5D dn C15 Standard Cal: Oil (2 cst), Forward flow direction, 6 points, 6 verification points, Range 2 ... 20 ft/sec, Lab pressure and temperature • Calibration, 100 DN (4 inch) • Calibration, 150 DN (6 inch) • Calibration, 200 DN (8 inch) • Calibration, 250 DN (10 inch) • Calibration, 300 DN (12 inch) • Calibration, 400 DN (16 inch) • Calibration, 450 DN (18 inch) • Calibration, 500 DN (20 inch) • Calibration, 600 DN (24 inch) • Calibration, Other contact factory for quote D10 D11 D12 D13 D14 D15 D16 D17 D18 Y28 Tag name plate • Stainless steel tags with 3.2 mm (0.13 inch) character size (68 characters max.) Y19 Selection and Ordering data Operating Instructions for SITRANS FUT1010 (Liquid) English NEMA 4X wall mount& NEMA 7 wall mount explosionproof German NEMA 4X wall mount & NEMA 7 wall mount explosionproof Article No. A5E02639184 A5E03086468 This device is shipped with a Quick Start Guide and a CD containing further SITRANS F literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Siemens FI 01 · 2016 3/383 © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUT1010 (Liquid and Gas) Selection and Ordering data SITRANS FUT1010 (Gas) Article No. Order Code 7 ME3 6 3 7 - 7 777 7 - 0 7 7 7 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. 3 Transmitter type No meter IP65 NEMA 4X (2 path) IP65 NEMA 4X (2 path) with Modbus IP65 NEMA 4X (3 or 4 path) IP65 NEMA 4X (3 or 4 path) with Modbus IP66 NEMA 7 wall mount flame/explosion proof (2 Path) IP66 NEMA 7 wall mount flame/explosion proof (2 Path) with Modbus IP66 NEMA 7 wall mount flame/explosion proof (3 or 4 Path) IP66 NEMA 7 wall mount flame/explosion proof (3 or 4 Path) with Modbus Input power 90 ... 240 V AC 9 ... 36 V DC Number of ultrasonic paths 2 path (standard enclosure material) 3 path (standard material) 4 path (standard material) Pipe size DN 100 (4") (Dual Path only) DN 150 (6")(Dual Path only) DN 200 (8") DN 250 (10") DN 300 (12") DN 400 (16") DN 450 (18") DN 500 (20") DN 600 (24") Flange rating Class 300 (Raised Face) Class 600 (Raised Face) Upstream/downstream meter run None 10 pipe diameter upstream Tube only 10 pipe diameter upstream Tube with flow conditioner 5 pipe diameter downstream tube only 10D up and 5D downstream tubes 10D up and 5D downstream tubes with flow conditioner Gas type range (select closest match) Natural Gas (mostly CH4) Process Gases (N2, O2, CO, Ar) Helium Hydrogen Gas temperature range -28 ... +65 °C (-20 ... +150 °F ) 1 ... 93 °C (30 ... 200 °F) Transmitter and sensor approval FM/CSA, CE ATEX and PED, CE, C-TICK 3/384 Siemens FI 01 · 2016 0 1 2 3 4 5 6 7 8 1 2 B C D A B C D E F G H J 1 2 0 1 2 3 4 5 A B C D A B 1 2 777 © Siemens AG 2016 Flow Measurement SITRANS F US Clamp-on SITRANS FUT1010 (Liquid and Gas) Order code Selection and Ordering data Further designs Please add "-Z" to Article No. and specify Order code(s). Cable assembly for flow sensor (Add one K.. per flow path) • Cable and termination for one sensor path (see "Transducer cable chart for options") K.. • Termination for user supplied cable T01 Cable assembly for temperature sensor (only 1 required) • Cable and termination for temperature sensor (see "Transducer cable chart for options"). R.. • Termination for user supplied RTD cable T31 3 Nace Certification • Nace, Spool only C10 • Nace, W/10D upstream C11 • Nace, W/10D upstream, cond C12 • Nace, W/5D downstream C13 • Nace, W/10D up, 5D dn C14 • Nace, W/10D up, cond, 5D dn C15 Standard Cal: Nat Gas, Forward flow direction, 7 points, 2 verification points, Range 10 ... 100 ft/sec, Lab pressure and temperature • Calibration, 100 DN (4 inch) • Calibration, 150 DN (6 inch) • Calibration, 200 DN (8 inch) • Calibration, 250 DN (10 inch) • Calibration, 300 DN (12 inch) • Calibration, 400 DN (16 inch) • Calibration, 450 DN (18 inch) • Calibration, 500 DN (20 inch) • Calibration, 600 DN (24 inch) • Calibration, Other contact factory for quote D10 D11 D12 D13 D14 D15 D16 D17 D18 Y28 Tag name plate • Stainless steel tags with 3.2 mm (0.13 inch) character size (68 characters max.) Y19 Selection and Ordering data Operating Instructions for SITRANS FUT1010 (Gas) English NEMA 4X wall mount & NEMA 7 wall mount explosionproof German NEMA 4X wall mount & NEMA 7 wall mount explosionproof Article No. A5E02639185 A5E03086485 This device is shipped with a Quick Start Guide and a CD containing further SITRANS F literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Siemens FI 01 · 2016 3/385