Download

Long-barrel Inductive Proximity Sensor
E2E2
CSM_E2E2_DS_E_4_3
Proximity Sensor with a Long Screw
Length
• Increased tightening strength. Cable protectors provided as a
standard feature.
• Increased indicator visibility. A milled section for wrench grip on all
models.
Be sure to read Safety Precautions on page 9.
Ordering Information
Sensors
DC 2-Wire Models
Appearance
Shielded
Unshielded
Sensing distance
M12
M18
M30
M12
M18
M30
3 mm
7 mm
10 mm
8 mm
14 mm
20 mm
Model
Operation mode
NO
E2E2-X3D1 2M *
E2E2-X7D1 2M *
E2E2-X10D1 2M *
E2E2-X8MD1 2M *
E2E2-X14MD1 2M *
E2E2-X20MD1 2M *
NC
E2E2-X3D2 2M
E2E2-X7D2 2M
E2E2-X10D2 2M
E2E2-X8MD2 2M
E2E2-X14MD2 2M
E2E2-X20MD2 2M
* Models with different frequencies are also available. The model numbers are E2E2-X@D15 (example: E2E2-X3D15).
DC 3-Wire Models
Appearance
Shielded
Unshielded
Sensing distance
M12
M18
M30
M12
M18
M30
2 mm
5 mm
10 mm
5 mm
10 mm
18 mm
Model
Operation mode
NO
E2E2-X2C1 2M
E2E2-X5C1 2M
E2E2-X10C1 2M
E2E2-X5MC1 2M
E2E2-X10MC1 2M
E2E2-X18MC1 2M
NC
E2E2-X2C2 2M
E2E2-X5C2 2M
E2E2-X10C2 2M
E2E2-X5MC2 2M
E2E2-X10MC2 2M
E2E2-X18MC2 2M
AC 2-Wire Models
Appearance
Shielded
Unshielded
Sensing distance
M12
M18
M30
M12
M18
M30
2 mm
5 mm
10 mm
5 mm
10 mm
18 mm
Model
Operation mode
NO
E2E2-X2Y1 2M
E2E2-X5Y1 2M
E2E2-X10Y1 2M
E2E2-X5MY1 2M
E2E2-X10MY1 2M
E2E2-X18MY1 2M
NC
E2E2-X2Y2 2M
E2E2-X5Y2 2M
E2E2-X10Y2 2M
E2E2-X5MY2 2M
E2E2-X10MY2 2M
E2E2-X18MY2 2M
1
E2E2
Accessories (Order Separately)
Mounting Brackets
Protective Covers
Sputter Protective Covers
Ratings and Specifications
E2E2-X@D@ DC 2-Wire Models
Size
Shielding
Item
Model
Sensing distance
M12
Shielded
E2E2-X3D@
M18
Unshielded
E2E2-X8MD@
Shielded
E2E2-X7D@
M30
Unshielded
E2E2-X14MD@
Shielded
E2E2-X10D@
Unshielded
E2E2-X20MD@
3 mm±10%
8 mm±10%
7 mm±10%
14 mm±10%
10 mm±10%
20 mm±10%
Set distance *1
0 to 2.4 mm
0 to 6.4 mm
0 to 5.6 mm
0 to 11.2 mm
0 to 8 mm
0 to 16 mm
Differential travel
10% max. of sensing distance
Sensing object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on
page 5.)
Standard sensing object
Iron,
Iron,
Iron,
Iron,
Iron,
Iron,
12 × 12 × 1 mm 30 × 30 × 1 mm 18 × 18 × 1 mm 30 × 30 × 1 mm 30 × 30 × 1 mm 54 × 54 × 1 mm
Response frequency *2
1 kHz
Power supply voltage
(operating voltage range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current
0.8 mA max.
Control
output
Switching
capacity
800 Hz
500 Hz
400 Hz
100 Hz
3 to 100 mA
Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators
D1 Models: Operation indicator (red) and setting indicator (green)
D2 Models: Operation indicator (red)
Operation mode
(with sensing object approaching)
D1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 8 for details.
D2 Models: NC
Protection circuits
Surge absorber, Load short-circuit protection
Ambient temperature
Operating/Storage: −25 to 70°C (with no icing or condensation)
Ambient humidity
Operating/Storage: 35% to 95% (with no condensation)
Temperature influence
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Voltage influence
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case
Vibration resistance
(destruction)
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
(destruction)
1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection
IEC IP67, in-house standard for oil resistance
Connection method
Pre-wired Models (Standard cable length: 2 m)
Weight (packed state)
Approx. 65 g
Case
Materials
Approx. 150 g
Approx. 210 g
Brass
Sensing surface PBT
Clamping nuts
Nickel-plated brass
Toothed washer
Zinc-plated iron
Accessories
Instruction sheet
*1. Use the E2E2 within the range in which the setting indicator (green LED) is ON (except D2 Models).
*2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
2
E2E2
E2E2-X@C@ DC 3-Wire Models
Size
Shielding
Item
Model
M12
M18
M30
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
E2E2-X2C@
E2E2-X5MC@
E2E2-X5C@
E2E2-X10MC@
E2E2-X10C@
E2E2-X18MC@
Sensing distance
2 mm±10%
5 mm±10%
5 mm±10%
10 mm±10%
10 mm±10%
18 mm±10%
Set distance
0 to 1.6 mm
0 to 4 mm
0 to 4 mm
0 to 8 mm
0 to 8 mm
0 to 14 mm
Differential travel
10% max. of sensing distance
Sensing object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on
page 5.)
Standard sensing object
Iron,
Iron,
Iron,
Iron,
Iron,
Iron,
12 × 12 × 1 mm 15 × 15 × 1 mm 18 × 18 × 1 mm 30 × 30 × 1 mm 30 × 30 × 1 mm 54 × 54 × 1 mm
Response frequency *1
1.5 kHz
Power supply voltage (operating voltage range) *2
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current
13 mA max.
Control
output
Load current
400 Hz
600 Hz
200 Hz
400 Hz
100 Hz
NPN open-collector output, 200 mA max. (30 VDC max.)
Residual voltage 2 V max. (Load current: 200 mA, Cable length: 2 m)
Indicators
Operation indicator (red)
Operation mode
(with sensing object approaching)
C1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 8 for details.
C2 Models: NC
Protection circuits
Reverse polarity protection, Surge absorber, Load short-circuit protection
Ambient temperature
Operating/Storage: −40 to 85°C (with no icing or condensation)
Ambient humidity
Operating/Storage: 35% to 95% (with no condensation)
Temperature influence
±15% max. of sensing distance at 23°C in the temperature range of −40 to 85°C
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Voltage influence
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance
(destruction)
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
(destruction)
1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection
IEC IP67, in-house standard for oil resistance
Connection method
Pre-wired Models (Standard cable length: 2 m) and Connector Models
Weight (packed state)
Approx. 75 g
Case
Materials
Approx. 160 g
Approx. 220 g
Brass
Sensing surface PBT
Clamping nuts
Nickel-plated brass
Toothed washer
Zinc-plated iron
Accessories
Instruction sheet
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
*2. A full-wave rectification power supply of 24 VDC ±20% (average value) can be used.
3
E2E2
E2E2-X@Y@ AC 2-Wire Models
Size
Shielding
Item
Model
M12
M18
M30
Shielded
Unshielded
Shielded
Unshielded
Shielded
Unshielded
E2E2-X2Y@
E2E2-X5MY@
E2E2-X5Y@
E2E2-X10MY@
E2E2-X10Y@
E2E2-X18MY@
Sensing distance
2 mm±10%
5 mm±10%
5 mm±10%
10 mm±10%
10 mm±10%
18 mm±10%
Set distance
0 to 1.6 mm
0 to 4 mm
0 to 4 mm
0 to 8 mm
0 to 8 mm
0 to 14 mm
Differential travel
10% max. of sensing distance
Sensing object
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on
page 5.)
Standard sensing object
Iron,
Iron,
Iron,
Iron,
Iron,
Iron,
12 × 12 × 1 mm 15 × 15 × 1 mm 18 × 18 × 1 mm 30 × 30 × 1 mm 30 × 30 × 1 mm 54 × 54 × 1 mm
Response frequency
25 Hz
Power supply voltage (operating voltage range) *1
24 to 240 VAC (20 to 264 VAC), 50/60 Hz
Leakage current
1.7 mA max.
Control
output
Load current *2
5 to 200 mA
5 to 300 mA
Residual voltage Refer to Engineering Data on page 5.
Indicators
Operation indicator (red)
Operation mode
(with sensing object approaching)
Y1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 8 for details.
Y2 Models: NC
Ambient temperature *1, 2
Operating/Storage: −40 to 85°C (with no icing or condensation)
Ambient humidity
Operating/Storage: 35% to 95% (with no condensation)
Temperature influence
±15% max. of sensing distance at 23°C in the temperature range of −40 to 85°C,
±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Voltage influence
±1% max. of sensing distance at rated voltage in the rated voltage ±15% range
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
4,000 VAC, 50/60 Hz for 1 minute between current carry parts and case
Vibration resistance
(destruction)
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
(destruction)
1,000 m/s2 10 times each in X, Y, and Z directions
Degree of protection
IEC IP67, in-house standard for oil resistance
Connection method
Pre-wired Models (Standard cable length: 2 m) and Connector Models
Weight (packed state)
Approx. 65 g
Case
Materials
Approx. 150 g
Approx. 210 g
Brass
Sensing surface PBT
Clamping nuts
Toothed washer
Accessories
Nickel-plated brass
Zinc-plated iron
Instruction sheet
*1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at least −25°C to 85°C.
*2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85°C, make sure that the Sensor has a control output (load current) of 5
to 200 mA max.
4
E2E2
Engineering Data (Reference Value)
E2E2-X@C@/-X@Y@
12
Distance X (mm)
Distance X (mm)
Sensing Area
Shielded Models
E2E2-X@D@
E2E2-X10
10
8
12
E2E2-X10
10
Y
8
X
E2E2-X7
6
6
E2E2-X5
4
4
Y
E2E2
-X2
E2E2-X3
X
2
0
−20
2
−15
−10
−5
0
5
10
15
0
−15
20
−10
−5
0
5
Distance Y (mm)
25
20
30
Y
X
25
20
E2E2
-X20M
15
E2E2-X18M
15
E2E2
-X14M
10
X
E2E2-X10M
10
E2E2
-X8M
Y
E2E2-X5M
5
0
−30
5
−20
−10
0
10
20
0
−30
30
−20
−10
0
10
Distance Y (mm)
Leakage Current
E2E2-X@D@
20
30
Distance Y (mm)
Residual Output Voltage
E2E2-X@D@
1.0
0.8
0.6
Residual output voltage (V)
E2E2-X@Y@
Leakage current (mA)
Leakage current (mA)
15
E2E2-X@MC@/-X@MY@
30
Distance X (mm)
Distance X (mm)
Unshielded Models
E2E2-X@MD@
10
Distance Y (mm)
1.4
1.2
1.0
0.8
0.4
0.6
6
5
4
3
Protective
resistance
0.4
mA
0.2
0.2
0
5
10
15
20
25
30
Power supply voltage (V)
0
2
AC
power
V
Proximity
Sensor (OFF)
50
100
150
200
250
300
Power supply voltage (V)
1
3
5
10
30
50
100
Load current (mA)
5
E2E2
30
E2E2-X@Y@
25
20
at 100 VAC
120
Residual output voltage
100
ON
80
Residual output voltage
60
15
VL
30
50
OFF
300 500
100
0
40
Residual
load
voltage
1
3
5
10
30
50
100
t = 1 mm
3
Iron
0
1
3
5
10
30
50
8
@d
X
7
OFF
300 500
100
Load current (mA)
E2E2-X10D@
t = 1 mm
Distance X (mm)
X
3.5
Distance (mm)
Distance X (mm)
Influence of Sensing Object Size and Material
E2E2-X3D@
E2E2-X7D@
@d
Residual
load
voltage
OFF
300 500
Load current (mA)
Load current (mA)
4
200 VAC
80
20
Residual
load
voltage
10
VL
A
24 VAC
5
5
160
120
40
A
3
ON
100 VAC
A
1
Residual output voltage
200
V
VL
V
0
at 200 VAC
240
V
ON
10
E2E2-X@Y@
Load voltage VL (V)
at 24 VAC
Load voltage VL (V)
Load voltage VL (V)
E2E2-X@Y@
Iron
6
12
@d
X
t = 1 mm
Iron
10
8
2.5
5
Stainless steel
(SUS304)
2
Stainless steel
(SUS304)
4
6
Stainless steel
(SUS304)
4
Brass
Aluminum
Copper
Brass
1.5
Brass
3
Aluminum
Copper
1
Aluminum
Copper
2
2
0.5
5
10
15
20
25
30
35
40
0
10
20
Side length of sensing object d (mm)
12
@d
X
40
t = 1 mm
10
8
0
50
E2E2-X14MD@
Distance X (mm)
Distance X (mm)
E2E2-X8MD@
30
10
20
25
@d
X
30
40
50
70
E2E2-X20MD@
t = 1 mm
20
25
@d
X
t = 1 mm
20
Iron
Iron
15
15
Iron
6
Stainless steel
(SUS304)
10
Brass
Aluminum
Copper
2
10
20
30
40
50
60
Brass
Aluminum
Copper
5
70
Side length of sensing object d (mm)
0
Stainless steel
(SUS304)
Stainless steel
(SUS304)
4
0
60
Side length of sensing object d (mm)
Side length of sensing object d (mm)
Distance X (mm)
0
1
10
20
30
40
50
60
10
Brass
Aluminum
Copper
5
70
Side length of sensing object d (mm)
0
10
20
30
40
50
60
70
80
90 100
Side length of sensing object d (mm)
6
E2E2
@d
X
E2E2-X5C@/-X5Y@
t = 1 mm
Iron
2
7
@d
t = 1 mm
X
6
E2E2-X10C@/-X10Y@
Distance X (mm)
2.5
Distance X (mm)
Distance X (mm)
E2E2-X2C@/-X2Y@
Iron
5
12
@d
X
t = 1 mm
Iron
10
8
Stainless steel (SUS304)
Stainless steel (SUS304)
1.5
4
Stainless steel (SUS304)
6
3
1
Brass
Brass
Brass
Aluminum
Aluminum
Aluminum
0.5
4
2
2
1
5
10
15
20
0
25
10
Side length of sensing object d (mm)
7
6
@d
X
30
40
50
E2E2-X10MC@/-X10MY@
Distance X (mm)
Distance X (mm)
E2E2-X5MC@/-X5MY@
20
t = 1 mm
Iron
5
0
10
20
Side length of sensing object d (mm)
12
@d
X
30
40
50
60
Side length of sensing object d (mm)
E2E2-X18MC@/-X18MY@
t = 1 mm
Iron
10
Distance X (mm)
0
25
@d
X
t = 1 mm
20
Iron
8
15
4
Stainless steel (SUS304)
Stainless steel (SUS304)
Stainless steel (SUS304)
6
3
10
2
Aluminum
Aluminum
2
1
0
10
20
30
40
50
Side length of sensing object d (mm)
0
Brass
Brass
4
Brass
10
20
30
40
50
60
Side length of sensing object d (mm)
Aluminum
5
0
20
40
60
80
100
Side length of sensing object d (mm)
7
E2E2
I/O Circuit Diagrams
DC 2-Wire Models
Operation
mode
Model
Timing Charts
Non-sensing
area
Output circuit
Unstable Set position
sensing
Stable sensing
area
area
Proximity Sensor
NO
E2E2-X3D1
E2E2-X7D1
E2E2-X10D1
E2E2-X8MD1
E2E2-X14MD1
E2E2-X20MD1
Sensing
object
(%)
100 80
Rated
sensing
distance
0
ON Setting indicator
OFF (green)
ON Operation
OFF indicator (red)
ON
Control output
OFF
Non-sensing
area
Brown
Load
+V
Proximity
Sensor
main
circuit
Blue
Stable sensing
area
0V
Proximity Sensor
NC
E2E2-X3D2
E2E2-X7D2
E2E2-X10D2
E2E2-X8MD2
E2E2-X14MD2
E2E2-X20MD2
Sensing
object
(%)
Note: The load can be connected to either
the +V or 0 V side.
100
0
Rated
sensing
distance
ON Operation
OFF indicator (red)
ON
Control output
OFF
DC 3-Wire Models
Operation
mode
NO
NC
Model
E2E2-X2C1
E2E2-X5C1
E2E2-X10C1
E2E2-X5MC1
E2E2-X10MC1
E2E2-X18MC1
E2E2-X2C2
E2E2-X5C2
E2E2-X10C2
E2E2-X5MC2
E2E2-X10MC2
E2E2-X18MC2
Timing Charts
Sensing object
Present
Not present
Operation indicator
(red)
OFF
Present
Not present
Operation indicator
(red)
Control output
Brown
ON
+V
100 Ω
OFF
Load
ON
Control output
Sensing object
Output circuit
Proximity
Sensor
main
circuit
Black
Blue
0V
ON
OFF
ON
OFF
8
E2E2
AC 2-Wire Models
Operation
mode
NO
NC
Model
Timing Charts
E2E2-X2Y1
E2E2-X5Y1
E2E2-X10Y1
E2E2-X5MY1
E2E2-X10MY1
E2E2-X18MY1
E2E2-X2Y2
E2E2-X5Y2
E2E2-X10Y2
E2E2-X5MY2
E2E2-X10MY2
E2E2-X18MY2
Sensing object
Present
Not present
ON
Operation indicator
(red)
Brown
OFF
Load
ON
Control output
Sensing object
Output circuit
Proximity
Sensor
main
circuit
OFF
Present
Not present
Operation indicator
(red)
Control output
Blue
ON
OFF
ON
OFF
Safety Precautions
WARNING
This product is not designed or rated for
ensuring safety of persons either directly or
indirectly.
Do not use it for such purposes.
Precautions for Correct Use
Do not use this product under ambient conditions that exceed
the ratings.
● Design
Influence of Surrounding Metal
When mounting the Sensor within a metal panel, ensure that
the clearances given in the following table are maintained.
l
n
m
d dia.
D
m
l
(Unit: mm)
Model
Item
Shielded
DC 2-Wire Models
E2E2-X@D@
Unshielded
Shielded
DC 3-Wire Models
E2E2-X@C@
AC 2-Wire Models
E2E2-X@Y@
Unshielded
l
d
D
m
n
l
d
D
m
n
l
d
D
m
n
l
d
D
m
n
M12
0
12
0
8
18
15
40
15
20
40
0
12
0
8
18
15
40
15
20
36
M18
0
18
0
20
27
22
70
22
40
70
0
18
0
20
27
22
55
22
40
54
M30
0
30
0
40
45
30
90
30
70
90
0
30
0
40
45
30
90
30
70
90
9
E2E2
Mutual Interference
When installing Sensors face-to-face or
side-by-side, ensure that the minimum
distances given in the following table
are maintained.
B
Size
A
Mutual Interference
(Unit: mm)
Model
Item
M12
30
(20)
M18
50
(30)
M30
100
(50)
B
20
(12)
35
(18)
70
(35)
A
120
(60)
200
(100)
300
(100)
B
100
(50)
110
(60)
200
(100)
A
B
A
B
30
20
120
100
50
35
200
110
100
70
300
200
A
Shielded
DC 2-Wire Models
E2E2-X@D@
Unshielded
DC 3-Wire Models
E2E2-X@C@
AC 2-Wire Models
E2E2-X@Y@
Relationship between Sizes and
Models
Shielded
Unshielded
Note: Values in parentheses apply to Sensors operating at different frequencies.
Model
E2E2-X3D@
Shielded
E2E2-X2C@
E2E2-X2Y@
M12
E2E2-X8MD@
Unshielded E2E2-X5MC@
E2E2-X5MY@
E2E2-X7D@
Shielded
E2E2-X5C@
E2E2-X5Y@
M18
E2E2-X14MD@
Unshielded E2E2-X10MC@
E2E2-X10MY@
E2E2-X10D@
Shielded
E2E2-X10C@
E2E2-X10Y@
M30
E2E2-X20MD@
Unshielded E2E2-X18MC@
E2E2-X18MY@
tening Torque
Do not tighten the nut with excessive force.
A washer must be used with the nut.
The following strengths assume washers are being used.
● Mounting
T
i
g
h
Model
Torque
M12
M18
M30
30 N·m
70 N·m
180 N·m
10
E2E2
(Unit: mm)
Dimensions
Unless otherwise specified, the tolerance class IT16 is used for dimensions in this data sheet.
Shielded
Unshielded
E2E2-X3D@/E2E2-X2C@/E2E2-X2Y@
60
21 dia.
17
E2E2-X8MD@/E2E2-X5MC@/E2E2-X5MY@
9
60
21 dia.
17
55
4
10
9
55
7
10
4
9 dia.
*1
*1
Indicators *2
M12 × 1
Two clamping nuts
Toothed washer
*1. 4-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm),
Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm),
Standard length: 2 m
The cable can be extended to up to 200 m (Separate metal conduit.)
*2. D Models: Operation indicator (red) and setting indicator (green),
C/Y Models: Operation indicator (red)
*1. 4-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm),
Standard length: 2 m
4-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm),
Standard length: 2 m
The cable can be extended to up to 200 m (Separate metal conduit.)
*2. D Models: Operation indicator (red) and setting indicator (green),
C/Y Models: Operation indicator (red)
E2E2-X7D@/E2E2-X5C@/E2E2-X5Y@
E2E2-X14MD@/E2E2-X10MC@/E2E2-X10MY@
65
29 dia.
24
Indicators *2
M12 × 1
Two clamping nuts
Toothed washer
65
12
29 dia.
24
60
4
10
12
60
10
4
10
14.8 dia.
*1
*1
Indicators *2
M18 × 1
Two clamping nuts
Toothed washer
E2E2-X10D@/E2E2-X10C@/E2E2-X10Y@
42 dia.
36
5
Two clamping nuts
Toothed washer
*1. 6-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
The cable can be extended to up to 200 m (Separate metal conduit.)
*2. D Models: Operation indicator (red) and setting indicator (green),
C/Y Models: Operation indicator (red)
*1. 6-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
The cable can be extended to up to 200 m (Separate metal conduit.)
*2. D Models: Operation indicator (red) and setting indicator (green),
C/Y Models: Operation indicator (red)
70
65
Indicators *2
M18 × 1
E2E2-X20MD@/E2E2-X18MC@/E2E2-X18MY@
70
12
42 dia.
36
10
12
65
13
5
10
26.8 dia.
*1
*1
Indicators *2
M30 × 1.5
Indicators *2
M30 × 1.5
Two clamping nuts
Toothed washer
Two clamping nuts
Toothed washer
*1. 6-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
The cable can be extended to up to 200 m (Separate metal conduit.)
*2. D Models: Operation indicator (red) and setting indicator (green),
C/Y Models: Operation indicator (red)
*1. 6-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
6-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm),
Standard length: 2 m
The cable can be extended to up to 200 m (Separate metal conduit.)
*2. D Models: Operation indicator (red) and setting indicator (green),
C/Y Models: Operation indicator (red)
Mounting Hole Dimensions
Dimension
F (mm)
M12
M18
+0.5
12.5 0
+0.5
18.5 0
dia.
M30
dia.
30.5
+0.5
0
dia.
F
Note 1. Two clamping nuts and one toothed washer are provided with each Sensors.
2. The model number is laser-marked on the cable section and milled section.
In the interest of product improvement, specifications are subject to change without notice.
11
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2015.11
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/