Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.) A165S/W CSM_A165S_W_DS_E_4_3 Separate Construction with Cylindrical 16-dia. Body • Same separate construction as the A16-series Pushbuttons with Miniature Design of 28.5 mm • The same contacts can be used for both standard loads and microloads. • Oil-resistant IP65 models • Conforms to EN60947-5-1. Refer to Safety Precautions for All Pushbutton Switches/ Indicators and Safety Precautions on page 15. List of Models Model Rectangular Solder terminals Voltagereduction lighting Screwless clamp connector Square Round A165@-J Series A165@-A Series A165@-T Series A165@-J Series A165@-A Series A165@-T Series A165@-J Series A165@-A Series A165@-T Series 1 A165S/W Model Number Structure Model Number Legend ..... The model numbers used to order sets of Units are illustrated below. One set comprises the Selector, Lamp (lighted models only), and Switch. For information on combinations, refer to Ordering Information on page 3. (1) (2) (3) (4) (5) (6) A165W - A 2A R - 24D - 1 (6) Contact Configuration Symbol 1 2 1P 2P 2S (1) Lighted/ Non-lighted Symbol S W Type Nonlighted Lighted (2) Shape of Selector Symbol J A T Shape Rectangular Square Round (3) Number of Notches/ Resetting Method Symbol No. of notches 2M 2 notches 2A No symbol Automatic R G Y Solder terminal PCB terminal Screw-less Clamp Color Black (non-lighted models only) Red Green Yellow (5) Light Source Symbol No symbol 24D Type Non-lighted 24-V LED Manual 3M 3 notches 3A Symbol Terminal Note: 1. Only DPDT contacts are available with 3-notch models and Screw-less Clamp models. 2. PCB terminals are available only with 2-notch models. (4) Color of Selector Reset method Manual Type SPDT DPDT SPDT DPDT DPDT Voltage Reduction Unit (24-V Built-in LED) Automatic Symbol Type T1 LED T2 Operating voltage 100/110 VAC/VDC 200/220 VAC/VDC Rated voltage 110 VAC/VDC 220 VAC/VDC Note: 1. Solder terminals are only available with 100-V models. 2. The Voltage Reduction Unit is not available for models with PCB terminals. 3. "T2" is available only for the Screw-less Clamp type. 2 A165S/W Ordering Information Ordering as a Set .................The model numbers used to order sets of Units are given in the following tables. One set comprises the Selector, Lamp (lighted models only), and Switch. Solder Terminals Rectangular A165@-J Oil-resistant IP65 No. of notches Output Reset method Manual SPDT Automatic 2 notches Manual DPDT Automatic 3 notches DPDT Manual Lighting method LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted Model A165W-J2M@-24D-1 A165S-J2M-1 A165W-J2A@-24D-1 A165S-J2A-1 A165W-J2M@-24D-2 A165S-J2M-2 A165W-J2A@-24D-2 A165S-J2A-2 A165W-J3M@-24D-2 A165S-J3M-2 Note: Enter the desired color symbol for the Selector in @: R (red); Y (yellow); G (green). The Selector for non-lighted models is black. Square A165@-A Oil-resistant IP65 No. of notches Output Reset method Manual SPDT Automatic 2 notches Manual DPDT Automatic 3 notches DPDT Manual Lighting method LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted Model A165W-A2M@-24D-1 A165S-A2M-1 A165W-A2A@-24D-1 A165S-A2A-1 A165W-A2M@-24D-2 A165S-A2M-2 A165W-A2A@-24D-2 A165S-A2A-2 A165W-A3M@-24D-2 A165S-A3M-2 Note: Enter the desired color symbol for the Selector in @: R (red); Y (yellow); G (green). The Selector for non-lighted models is black. Round A165@-T Oil-resistant IP65 No. of notches Output Reset method Manual SPDT Automatic 2 notches Manual DPDT Automatic 3 notches DPDT Manual Lighting method LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted Model A165W-T2M@-24D-1 A165S-T2M-1 A165W-T2A@-24D-1 A165S-T2A-1 A165W-T2M@-24D-2 A165S-T2M-2 A165W-T2A@-24D-2 A165S-T2A-2 A165W-T3M@-24D-2 A165S-T3M-2 Note: Enter the desired color symbol for the Selector in @: R (red); Y (yellow); G (green). The Selector for non-lighted models is black. 3 A165S/W Ordering Information Ordering Individually ......... Selectors, Lamps, and Switches can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Selector (Listed on Page 5.) Rectangular Models Square Models Round Models Lighted Models Non-lighted Models Lamp LED only Note: Temperature rises in incandescent lamps can cause heat deformation. Switch (Listed on Page 7.) Solder terminals (no transformer) Lighted/non-lighted PCB terminals Lighted/non-lighted Note: Switch Units that combine a Lamp and a Switch are also available. 4 A165S/W Ordering Information Ordering Individually .........Selectors, Lamps, and Switches (Sockets) can be ordered separately. Combinations that are not available as sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs. Selectors (Oil-resistant IP65 Models Only) Appearance Number of notches Rectangular (A165@-J) Reset method Manual 2 notches Automatic Manual 3 notches Square (A165@-A) Fully automatic Manual 2 notches Automatic Manual 3 notches Round (A165@-T) Fully automatic Manual 2 notches Automatic Manual 3 notches Fully automatic Lighting method LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted LED Non-lighted Model A165W-J2M@ A165S-J2M A165W-J2A@ A165S-J2A A165W-J3M@ A165S-J3M A165W-J3A@ A165S-J3A A165W-A2M@ A165S-A2M A165W-A2A@ A165S-A2A A165W-A3M@ A165S-A3M A165W-A3A@ A165S-A3A A165W-T2M@ A165S-T2M A165W-T2A@ A165S-T2A A165W-T3M@ A165S-T3M A165W-T3A@ A165S-T3A Selector color symbol Enter the desired color symbol for the Selector in @. R (red), Y (yellow), G (green) Enter the desired color symbol for the Selector in @. R (red), Y (yellow), G (green) Enter the desired color symbol for the Selector in @. R (red), Y (yellow), G (green) Note: The selector for non-lighted models is black. 5 A165S/W Ordering Information Sets .............................................. Select an Operation Unit and a Switch Unit (Lamp and Switch). Operation Unit Set with Knob-type Selector Switch Rectangular Models Square Models Round Models Lighted Models Lighted/Non-lighted Models Switch Unit with Voltage-reduction Lighting Switch Unit with Screw-less Clamp Connectors Lamp Voltagereduction Lighting Lamp Lighted/ Non-lighted Models Note: The LED has a 24-VAC/VDC circuit built in. Note: Non-lighted models do not include a Lamp. Switch Units (A Switch Unit includes a Switch and a Lamp.) Appearance Number of notches Classification 2 notches SPDT DPDT 3 notches DPDT 24 V Solder terminals Model A16W-2N@-24D-1 A16W-2N@-24D-2 A16W-3N@-24D-2 Switch Units with Voltage Reduction Units (Solder Terminals) Appearance Classification 2 notches Standard loads and microloads 2 notches 3 notches Operating voltage SPDT A16L-@-T1-1 100/110 VAC/VDC DPDT Model A16L-@-T1-2 A16W-3N@-T1-2 Note: The LED has a 24-VAC/VDC circuit built in. Insert one of the following letters into the box (@). Symbol R Y G Light color Red Yellow Green 6 A165S/W Ordering Information Switch Units with Screw-less Clamp Connectors Appearance Standard loads and microloads Classification Non-lighted No voltage-reduction lighting 100/110 VAC/VDC Lighted Voltage-reduction lighting 200/220 VAC/VDC Non-lighted No voltage-reduction lighting Lighted 100/110 VAC/VDC Voltage-reduction lighting 200/220 VAC/VDC 2 notches DPDT 3 notches DPDT Note: The 100-V models and 200-V models have a 24-VAC/VDC circuit built in. Ordering Individually Insert symbols in Δ and @. Δ Symbol Light color R Red Y Yellow G Green Model A16-2S A16L-Δ-@-2S A16L-Δ-T1-2S A16L-Δ-T2-2S A16S-3N-2LS A16W-3NΔ-@-2S A16W-3N-Δ-T1-2S A16W-3N-Δ-T2-2S @ Symbol 5D 12D 24D Remarks Used for Pushbutton Switches and Knob-type Selector Switches. Type Operating voltage 5 VDC 12 VAC/VDC 24 VAC/VDC LED Switches Appearance Classification SPDT DPDT DPDT SPDT DPDT DPDT SPDT DPDT SPDT DPDT 2 notches Lighted 3 notches Switches (without voltage-reduction lighting) Non-lighted 2 notches 3 notches Lighted 2 notches Non-lighted Model A16S-2N-1L A16S-2N-2L A16S-3N-2L A16S-2N-1 A16S-2N-2 A16S-3N-2 A16S-2N-1LP A16S-2N-2LP A16S-2N-1P A16S-2N-2P Solder terminal PCB terminal Lamps Operating voltage Super-bright 5 VDC Light color Red Yellow Green 12 VAC/VDC A16-5DSR A16-5DSY A16-5DSG A16-12DSR A16-12DSY A16-12DSG 24 VAC/VDC A16-24DSR A16-24DSY A16-24DSG Accessories and Tools (Order Separately) Accessories Name Appearance Panel Plugs Classification Rectangular Model A16ZJ-3003 Square A16ZA-3003 Round A16ZT-3003 Remarks Used for covering the panel cutouts for future panel expansion. Degree of protection: IP40 Tools Name Appearance Model Pushbutton Switch Applicable types Knob-type Key-type Emergency Selector Switch Selector Switch Stop Switch Remarks Indicator Screw Fitting A16Z-3004 Yes Yes Yes Yes Yes Convenient for ganged installation. Tighten to a torque of 0.39 N·m min. Extractor A16Z-5080 Yes Yes Yes Yes Yes Convenient for extracting the Switches and Lamps. Ordering as a Set: Refer to page 3. ■ Specifications and dimensions: Refer to pages 8 to 10. ■ Accessories, replacements, and tools: Refer to this page 7 A165S/W Specifications Approved Standard Ratings UL, cUL (File No. E41515) TÜV (EN60947-5-1) (Low Voltage Directive) CCC (GB14048.5) 5 A at 125 VAC, 3 A at 250 VAC (general use) 3 A at 30 VDC (resistive) 3 A at 250 VAC 3 A at 30 VDC 5 A at 125 VAC 3 A at 250 VAC 3 A at 30 VDC Note: Certification has been obtained for the Switch. For detailed information on individual products that have received certification, consult your supplier. Ratings Switch Ratings Contact Form Rated voltage 125 VAC 250 VAC 30 VDC Resistive load 5A 3A 3A Minimum applicable load: 1 mA at 5 VDC Rated values are obtained from tests conducted under the following conditions. 1. Load: Resistive load 2. Mounting conditions: No vibration and no shock 3. Temperature: 20±2°C 4. Operating frequency: 20 times/min Name Contact form NC SPDT COM NO Super-bright LED Rated voltage Rated current Operating voltage 5 VDC±5% 5 VDC 12 VAC/VDC 8 mA 12 VAC/VDC±5% 24 VAC/VDC 24 VAC/VDC±5% Internal limiting resistor Red, yellow: 300 Ω Green: 160 Ω Red, yellow: 1 kΩ Green: 910 Ω 2.4 kΩ Characteristics Socket Unit Item Screw-less Clamp Type Knob-type Selector Switch Allowable Mechanical operating frequency Electrical 20 operations/minute max. Insulation resistance 100 MΩ min. (at 500V DC) Contact resistance 100 mΩ max. (initial value) Between terminals of same polarity Dielectric strength 10 operations/minute max. 1,000 VAC, 50/60 Hz for 1 min Between terminals of dif- 2,000 VAC, 50/60 Hz for 1 min ferent polarity Between each terminal and ground 2,000 VAC, 50/60 Hz for 1 min Between lamp terminals 1,000 VAC, 50/60 Hz for 1 min* Vibration Malfunction resistance 10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms) Destruction Shock resistance Malfunction 500 m/s2 max. Durability 2 150 m/s max. (malfunction within 1 ms) Mechanical 250,000 operations min. Electrical 100,000 operations min. Electric shock protection class Item Type Recommended wire size Usable wires and tensile strength Twisted wire Solid wire Tensile strength Screw-less Clamp 0.5 mm2 twisted wire or 0.8 mm-dia. solid wire 0.3 mm2 0.5 mm2 0.5 mm dia. 0.8 mm dia. 1.0 mm dia. 10 N 20 N Length of exposed wire Compliant standards 0.75 mm2 30 N 1.25 mm2 --40 N 10 ±1 mm JIS C 2811 Terminal Blocks for Industrial Use Operating Characteristics Characteristics Type Knob-type Selector Switch 2 notches Operating torque (OF) max. Set position (SP) 3 notches 0.1 N·m 90±5° 45° +100 Class II PTI (tracking characteristic) 175 Degree of contamination 3 (IEC60947-5-1) Weight Approx. 13 g (in the case of a lighted DPDT switch) Ambient operating temperature −10°C to 55°C (with no icing or condensation) Ambient operating humidity 35% to 85%RH Ambient storage temperature −25°C to 65°C (with no icing or condensation) * With LED not mounted. (Perform testing with the LED not mounted.) 8 A165S/W Specifications Operation Angle Contact Form Two notches Three notches (75°) (45°) 45° 90° FP FP (45°) 45° Contact from No. of SPDT DPDT notches PosiPosiSW SW2 SW1 tion tion 2 notches Note: The angle used for automatic reset is shown in parentheses. FP: Free Position 3 notches --SW2 SW1 Nomenclature Model structure Selector ●Flange Shape Rectangular (A165@-J) ●Color of Selector · LED models Red Yellow Green · Non-lighted models Black ●Lighting Method · Lighted (LED) models (The upper face of the knob is illuminated.) · Non-lighted models Square (A165@-A) Round (A165@-T) ●Number of Notches and Reset Method · 2 Notches: Manual reset, Automatic reset · 3 Notches: Manual reset, Automatic reset ●Protective Structure Oil-resistant IP65 Switch ●Switch Specifications 5 A at 125 VAC 5 A at 250 VAC 3 A at 30 VDC Minimum applicable load: 1 mA at 5 VDC ●Terminal Type Solder terminals PCB terminals The flange can be rotated to easily change the operation angle of the knob. For information on rotating the flange, refer to page 14. Example: Knob-type Selector Switch with Two Notches FP (75°) 90° 90° 90° (Standard condition when shipped) Note: The angle is 75° for self-resetting models. 9 A165S/W Dimensions • The Dimension shows 2-switch outputs. (Unit: mm) • The lamp terminal is not provided with non-lighted models. Rectangular A165@-J Solder terminals (tab terminals #110) M16×1 12.2 4 18 Lamp terminal 10.8 9.5 21.1 28.5 18.5 24 6 4.85 12.4 15.8 18 Model, ratings, standard Mounting nut Packing (t0.5) Note: See page 12 for panel cutouts. Lock ring M16×1 Square A165@-A Solder terminals (tab terminals #110) 12.2 4 18 Lamp terminal 10.8 9.5 18 6 21.1 28.5 18.5 4.85 12.4 15.8 18 Model, ratings, standard Mounting nut Packing (t0.5) Note: See page 12 for panel cutouts. Lock ring Round A165@-T Solder terminals (tab terminals #110) M16×1 12.2 4 18 Lamp terminal 10.8 9.5 18 6 18.5 21.1 28.5 4.85 12.4 15.8 18 Model, ratings, standard Note: See page 12 for panel cutouts. Packing (t0.5) Mounting nut Lock ring 10 A165S/W Dimensions • The Dimension shows 2-switch outputs. (Unit: mm) • A rectangular model is listed as an example. M16×1 Rectangular A165@-J PCB terminals 18.4 20.4 0.5 9.5 24 6 18.5 • The lamp terminal is not also provided with nonlighted models. 6.3 4 10.8 21.1 28.3 18 4.85 12.4 18.6 0.5 Mounting nut Note: See page 12 for panel cutouts. Rectangular A165W@-T Reduced-voltage lighting solder terminals (tab terminals #110) Packing (t0.5) Lock ring 50.1 42.7 18.5 9.5 28.5 21.1 10.8 Panel Cutouts 4 0.5 Direction-indication arrow 0.5 Selector 16 +0.2 0 dia. 24 min. 12.2 9.8 18 0.5 M16×1 23 min. Case Packing (t0.5) 6 Lock ring Mounting nut Switch (22.4) 20.6 18 8.8 16.6 2.8 12.4 2.8 24 Rectangular A165@-2S Screw-Less Clamp 18.5 9.5 48.9 Panel Cutouts 10.8 4 2 24 23.9 16 +0.2 0 dia. 25 min. M16×1 6 Switch dismounting lever Lock ring 33 min. Mounting nut • The lamp terminal is also provided with nonlighted models. (31.7) 27.4 18 24 23.5 Packing (t0.5) 11 A165S/W Dimensions (Unit: mm) Panel Cutouts Models with Solder Terminals and Models with Screw-less Clamp Connectors Rectangular A165@-J Square A165@-A, Round A165@-T (Top View) +0.2 16 0 (Top View) 16 24 min. (25 min.) dia. +0.2 0 dia. 19 min. (25 min.) 19 min. (33 min.) 19 min. (33 min.) Note: 1. Make sure the thickness of the mounting panel is 0.5 to 3.2 mm. 2. If the panel is to be finished with coating, etc., make sure that the panel meets the specified dimensions after coating. 3. Figures in parentheses are for screw-less clamp connectors. Models with PCB Terminals Rectangular A165@-J Square A165@-A, Round A165@-T (Top View) (Top View) 16 +0.2 0 dia. 24 min. 16 9.1±0.05 +0.2 0 dia. 24 min. 9.1±0.05 14.7±0.05 dia. 14.7±0.05 dia. 24 min. 5.1±0.05 24 min. 5.1±0.05 Note: 1. Ensure that the variation in the distance between the centers of neighboring mounting holes is less than ±0.1 mm. 2. Make sure the thickness of the mounting panel is 0.5 to 3.2 mm. If, however, a Switch Guard or Dust Cover is used, the thickness of the mounting panel must be 0.5 to 2 mm. 3. If the panel is to be finished with coating, etc., make sure that the panel meets the specified dimensions after coating. Terminal Arrangement Models with Solder Terminals without Reduced-voltage Lighting (Lamp terminals are not provided with the Non-lighted Knob-type Selector Switches and Key-type Selector Switches.) Lighted SPDT Switches Lighted DPDT Switches Terminal Arrangement (Bottom View) Dimensions of Terminal Holes NC 2.6 0.9 Terminal Arrangement (Bottom View) Dimensions of Terminal Holes 2.6 0.9 COM 1.5 2.8 18 Note: The L+ is not shown on the Switch. 1.5 2.8 12.2 Lamp terminal Non-lighted SPDT Switches 18 COM SW1 SW2 Note: The L+ is not shown on the Switch. Terminal Arrangement (Bottom View) Side with TOP indicated Side with TOP indicated Dimensions of Terminal Holes Dimensions of Terminal Holes 1.5 2.8 NO COM Non-lighted DPDT Switches Terminal Arrangement (Bottom View) 2.6 0.9 NC L- NO 7.4 SW1 12.2 Lamp terminal NC L- NO 7.4 7.4 2.6 0.9 NC 12.2 18 NO COM SW1 1.5 2.8 7.4 NC 12.2 18 NC NO NO COM COM SW1 SW2 12 A165S/W Dimensions (Unit: mm) Models with PCB Terminals Lighted SPDT Switches Model, rating, and lot number indication Dimensions of PCB Terminals Lighted DPDT Switches Terminal Arrangement (Bottom View) Terminal Arrangement (Bottom View) Dimensions of PCB Terminals Side with TOP indicated Side with TOP indicated 5.3 5.3 3.5 NC 1.5 3.5 L- NC 1.5 NO COM 0.8 SW1 4.85 2.7 0.8 4.85 2.7 18.6 Lamp terminal (t=0.5) PCB Cutouts (Bottom View) NO COM COM SW1 SW2 18.6 PCB Cutouts (Bottom View) Side with TOP indicated Side with TOP indicated A±0.1 12.4±0.05 20±0.1 NC 12.4 12.4 Lamp terminal (t=0.5) L- NO 12.4±0.05 20±0.1 4.85±0.05 L±0.1 Five, 1 dia. 6.3±0.05 A±0.1 Two, 5 dia. A = 24 min.: Rectangular A = 21 min.: Square/Round L = 24 min. Use t = 1.6 for the PCB. 4.85±0.05 6.3±0.05 6.3±0.05 L±0.1 Two, 5 dia. A = 24 min.: Rectangular A = 21 min.: Square/Round L = 24 min. Use t = 1.6 for the PCB. Eight, 1 dia. Note: Secure the panel to the board using stud bolts if force will be applied to the board after wiring. Note: Secure the panel to the board using stud bolts if force will be applied to the board after wiring. Note: For details of the terminal arrangement for Screw-Less Clamps, refer to the corresponding section for the A16. 13 A165S/W Dimensions (Unit: mm) Non-lighted Models with PCB Terminals (Lamp terminals are not provided with the Non-lighted Knob-type Selector Switches and Key-type Selector Switches.) Non-lighted SPDT Switches Dimensions of PCB Terminals Non-lighted DPDT Switches Terminal Arrangement (Bottom View) Model, rating, and lot number indication Side with TOP indicated 5.3 Terminal Arrangement (Bottom View) Dimensions of PCB Terminals Side with TOP indicated 5.3 NC NC 3.5 3.5 NO 1.5 1.5 COM SW1 0.8 12.4 2.7 0.8 NO COM COM SW1 SW2 12.4 2.7 18.6 18.6 PCB Cutouts (Bottom View) Side with TOP indicated NC NO PCB Cutouts (Bottom View) Side with TOP indicated A±0.1 20±0.1 A±0.1 20±0.1 12.4±0.05 12.4±0.05 L±0.1 Three, 1 dia. 6.3±0.05 Two, 5 dia. A = 24 min.: Rectangular A = 21 min.: Square/Round L = 24 min. Use t = 1.6 for the PCB. 6.3±0.05 6.3±0.05 L±0.1 Two, 5 dia. A = 24 min.: Rectangular A = 21 min.: Square/Round L = 24 min. Use t = 1.6 for the PCB. Six, 1 dia. Note: Secure the panel to the board using stud bolts if force will be applied to the board after wiring. Note: Secure the panel to the board using stud bolts if force will be applied to the board after wiring. For details on mounting the Switch to a panel, and mounting and dismounting the Switch, refer to installation details for the A16 Pushbutton Switch. Flange Rotation (All Selector Switches) A165 Knob-type Selector Switch A165 Key-type Selector Switch Fix the Switch screw and rotate the flange in 45° turns. Fix the Switch screw and rotate the flange in 45° turns. Flange Flange Lock ring Lock ring Switch screw Switch screw 14 A165S/W Safety Precautions Refer to Safety Precautions for All Pushbutton Switches/Indicators. WARNING Always turn OFF the power and wait for 10 minutes before replacing the incandescent lamp. If the lamp is replaced immediately after the power is turned OFF, the remaining heat may cause burns. Precautions for Correct Use Mounting • Always make sure that the power is turned OFF before mounting, removing, or wiring the Switch, or performing maintenance. • Do not tighten the mounting nut more than necessary using tools such as pointed-nose pliers. Doing so will damage the mounting nut. The tightening torque is 0.29 to 0.49 N·m. Using the Microload • Insert a contact protection circuit, if necessary, to prevent the reduction of life expectancy due to extreme wear on the contacts caused by loads where inrush current occurs when the contact is opened and closed. • The A16 allows both a standard load (125 V at 5A, 250 V at 3 A) and a microload. If a standard load is applied, however, the microload area cannot be used. If the microload area is used with a standard load, the contact surface will become rough, and the opening and closing of the contact for a microload may become unreliable. • The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% (λ 60) (conforming to JIS C5003). The equation, λ 60 = 0.5 × 10-6/operations indicates that the estimated malfunction rate is less than 1/2,000,000 operations with a reliability level of 60%. Voltage (V) Do not apply a voltage between the incandescent lamp and the terminal that is greater than the rated voltage. If the incandescent lamp is broken, the operating part may pop out. Wiring • Solder terminals and quick-connect terminals (#110) are commonly used for terminals. • Be sure to use electrical wires that are a size appropriate for the applied voltage and carry current (conductor size is 0.5 to 0.75 mm2). Perform soldering according to the conditions provided below. If the soldering is not properly performed, the lead wires will become detached, resulting in short-circuits. 1. Hand soldering: 350°C, within 3 s 2. Dip soldering: 350°C, within 3 s Wait for one minute after soldering before exerting any external force on the solder. • Use non-corrosive resin fluid as the flux. • Make sure that the electric cord is wired so that it does not touch the Unit. If the electric cord touches the Unit, then electric wires with a heat resistance of 100°C min. must be used. • After wiring the Switch, maintain an appropriate clearance and creepage distance. Operating Environment • The IP65 model is designed with a degree of protection so that it will not sustain damage if it is subjected to water from any direction to the front of the panel. 0.15 mA 30 24 Microload area 12 Invalid area 5 1 mA 0 0.1 1 10 100 1,000 Current (mA) LED • The LED current-limiting resistor is built-in, so external resistance is not required. Rated voltage 5 VDC 12 VAC/VDC 24 VAC/VDC Internal limiting resistor Red, yellow: 300 Ω Green: 160 Ω Red, yellow: 1 kΩ Green: 910 Ω 2.4 kΩ 15 A165S/W Others • The oil-resistant IP65 uses NBR rubber and is resistant to general cutting oil and cooling oil. Some particular oils cannot be used with the oil-resistant IP65, however, so contact your OMRON representative for details. • If the panel is to be finished with coating, etc., make sure that the panel meets the specified dimensions after the coating. • Do not subject the Switch to extreme shock or vibration. Doing so will cause malfunctions and damage to the Switch. Do not let sharp objects come into contact with the Switches that are made of resin. Doing so will damage the Switches, causing scratches on the outside of the operating parts, and malfunction. When handling the Switches, do not throw or drop them. Do not allow the Switch to drop and hit the ground. Do not place or drop heavy objects on the Switch. Do not operate the Switch with hard or sharp objects. Hammer Screwdriver 16 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2015.9 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2015 All Right Reserved.