MUX8522 (10/13)

Standard Products
MUX8522 Dual 16-Channel Analog Multiplexer Module
Radiation Tolerant
www.aeroflex.com/mux
October 9, 2013
FEATURES


32-channels provided by two independent 16-channel multiplexers
Radiation performance
- Total dose:
300 krads(Si), Dose rate = 50 - 300 rads(Si)/s
- SEU:
Immune up to 120 MeV-cm2/mg
- SEL:
Immune by process design

Full military temperature range

Low power consumption < 30mW

Separate address (A0~A3 & B0~B3) and enable (EN0-15 & EN16-31) for CH0-15 and CH16-31

Fast access time 1500ns typical

Break-Before-Make switching

High analog input impedance (power on or off )

Designed for aerospace and high reliability space applications
Packaging – Hermetic ceramic
- 56 leads, 0.80"Sq x 0.20"Ht quad flat pack
- Typical Weight 6 grams


Aeroflex Plainview’s Radiation Hardness Assurance Plan is DLA Certified to MIL-PRF-38534, Appendix G.
GENERAL DESCRIPTION
Aeroflex’s MUX8522 is a radiation tolerant, dual 16 channel multiplexer MCM (Multi Chip Module).
The MUX8522 has been specifically designed to meet exposure to radiation environments. It is available in
a 56 lead High Temperature Co-Fired Ceramic (HTCC) Quad Flatpack (CQFP). It is guaranteed operational
from -55°C to +125°C. Available screened in accordance with MIL-PRF-38534, the MUX8522 is ideal for
demanding military and space applications.
ORGANIZATION AND APPLICATION
The MUX8522 consists of two independent 16 channel multiplexers arranged as shown in the block
diagram.
A Section
Sixteen (16) channels addressable by bus A0~A3, enabled by EN0-15 and outputted on Output1( 0-15).
B Section
Sixteen (16) channels addressable by bus B0~B3, enabled by EN16-31 and outputted on Output2(16-31).
SCD8522 Rev D
SECTION A
CH 0
16
•
•
•
MUX 1
CH 15
OUTPUT1 (0-15)
EN (0-15)
A0
A1
A2
A3
SECTION B
CH 16
16
•
•
•
MUX 2
CH 31
OUTPUT2 (16-31)
EN (16-31)
B0
B1
B2
B3
+VEE
-VEE
VREF
GND
MUX8522: DUAL 16 CHANNEL ANALOG MUX BLOCK DIAGRAM
SCD8522 Rev D 10/9/13
2
Aeroflex Plainview
ABSOLUTE MAXIMUM RATINGS 1/
Parameter
Range
Units
Case Operating Temperature Range
-55 to +125
°C
Storage Temperature Range
-65 to +150
°C
+16.5
-16.5
+16.5
V
V
V
< VREF +4
> GND -4
V
V
±35V
V
Supply Voltage
+VEE (Pin 18)
-VEE (Pin 46)
VREF (Pin 39)
Digital Input Overvoltage
VEN0-15 (Pin 13), VEN16-31 (Pin 44), VA (Pins 14, 15, 16, 17), VB (Pins 40, 41, 42, 43)
Analog Input Over Voltage
VIN
Notes:
1/ All measurements are made with respect to ground.
NOTICE: Stresses above those listed under "Absolute Maximums Rating" may cause permanent damage to the device. These are stress rating
only; functional operation beyond the "Operation Conditions" is not recommended and extended exposure beyond the "Operation Conditions" may
affect device reliability.
RECOMMENDED OPERATING CONDITIONS 1/
Symbol
Parameter
Typical
Units
+VEE
+15V Power Supply Voltage
+15.0
V
-VEE
-15V Power Supply Voltage
-15.0
V
VREF
Reference Voltage
+5.00
V
VAL
Logic Low Level
+0.8
V
VAH
Logic High Level
+4.0
V
1/ Power Supply turn-on sequence shall be as follows: +VEE, -VEE, followed by VREF.
DC ELECTRICAL PERFORMANCE CHARACTERISTICS 1/
(TC = -55°C TO +125°C, +VEE = +15V, -VEE = -15V, VREF = +5.0V - UNLESS OTHERWISE SPECIFIED)
Parameter
Supply Current
Address Input Current
7/
Enable Input Current
7/
SCD8522 Rev D 10/9/13
Symbol
Conditions
Min
Max
Units
+IEE
VEN(0-15) = VEN(16-31) = VA(0-3) = VB(0-3) = 0
0.1
1
mA
-IEE
VEN(0-15) = VEN(16-31) = VA(0-3) = VB(0-3) = 0
-1
-0.1
mA
+ISBY
VEN(0-15) = VEN(16-31) = 4V, VA(0-3) = VB(0-3) = 0 6/
0.1
1
mA
-ISBY
VEN(0-15) = VEN(16-31) = 4V, VA(0-3) = VB(0-3) = 0 6/
-1
-0.1
mA
IAL(0-3)A
VA = 0V
-1
1
A
IAH(0-3)A
VA = 5V
-1
1
A
IAL(0-3)B
VB = 0V
-1
1
A
IAH(0-3)B
VB = 5V
-1
1
A
IENL(0-15)
VEN(0-15) = 0V
-1
1
A
IENH(0-15)
VEN(0-15) = 5V
-1
1
A
IENL(16-31)
VEN(16-31) = 0V
-1
1
A
IENH(16-31)
VEN(16-31) = 5V
-1
1
A
3
Aeroflex Plainview
DC ELECTRICAL PERFORMANCE CHARACTERISTICS 1/ (continued)
(TC = -55°C TO +125°C, +VEE = +15V, -VEE = -15V, VREF = +5.0V - UNLESS OTHERWISE SPECIFIED)
Parameter
Symbol
Conditions
Min
Max
Units
Positive Input
Leakage Current
(CH0-CH31)
+ISOFFOUTPUT(ALL)
VIN = +10V, VEN = 4V, output and all unused MUX inputs
under test = -10V 2/, 3/, 7/
-100
+100
nA
Negative Input
Leakage Current
(CH0-CH31)
-ISOFFOUTPUT(ALL)
VIN = -10V, VEN = 4V, output and all unused MUX inputs
under test = +10V 2/, 3/, 7/
-100
+100
nA
Positive Output
Leakage Current
OUTPUTS (pins 12,45)
+IDOFFOUTPUT(ALL)
VOUT = +10V, VEN = 4V, output and all unused MUX
inputs under test = -10V 3/, 4/, 7/
-100
+100
nA
Negative Output
Leakage Current
OUTPUTS (pins 12,45)
-IDOFFOUTPUT(ALL)
VOUT = -10V, VEN = 4V, output and all unused MUX
inputs under test = +10V 3/, 4/, 7/
-100
+100
nA
RDS(ON)(0-31)A
VIN = +15V, VEN = 0.8V, IOUT = -1mA 2/, 3/, 5/
500
3000

RDS(ON)(0-31)B
VIN = +5V, VEN = 0.8V, IOUT = -1mA 2/, 3/, 5/
500
3000

RDS(ON)(0-31)C
VIN = -5V, VEN = 0.8V, IOUT = +1mA 2/, 3/, 5/
500
3000

Switch ON Resistance
OUTPUTS (pins 12,45)
Notes:
1/ Measure inputs sequentially. Ground all unused inputs of the device under test. VA is the applied input voltage to the address lines A(0-3). VB is
the applied input voltage to the address lines B(0-3).
2/ VIN is the applied input voltage to the input channels (CH0-CH31).
3/ VEN 0-15 is the applied input voltage to the enable line EN (0-15). VEN 16-31 is the applied input voltage to the enable line EN (16-31)
4/ VOUT is the applied input voltage to the output lines OUTPUT1 (0-15), OUTPUT2 (16-31)
5/ Negative current is the current flowing out of each of the MUX pins. Positive current is the current flowing into each MUX pin.
6/ Not tested, guaranteed to the specified limits.
7/ These parameters for TC = -55°C are guaranteed by design, characterization, or correlation to other test parameters.
SWITCHING CHARACTERISTICS
(TC = -55°C TO +125°C, +VEE = +15V, -VEE = -15V, VREF = +5.0V -- UNLESS OTHERWISE SPECIFIED)
Parameter
Switching Test MUX
Symbol
Conditions
Min
Max
Units
tAHL
RL = 10KCL = 50pF
10
1500
ns
tALH
RL = 10KCL = 50pF
Tc = +25°C, +125°C
Tc = -55°C
10
10
2000
5000
ns
ns
10
1500
ns
10
1000
ns
tONEN
tOFFEN
SCD8522 Rev D 10/9/13
RL = 1KCL = 50pF
4
Aeroflex Plainview
TRUTH TABLE (CH0–CH15)
A3
A2
A1
A0
EN (0-15)
"ON" CHANNEL, 1/ (OUTPUT 1)
X
X
X
X
H
NONE
L
L
L
L
L
CH0
L
L
L
H
L
CH1
L
L
H
L
L
CH2
L
L
H
H
L
CH3
L
H
L
L
L
CH4
L
H
L
H
L
CH5
L
H
H
L
L
CH6
L
H
H
H
L
CH7
H
L
L
L
L
CH8
H
L
L
H
L
CH9
H
L
H
L
L
CH10
H
L
H
H
L
CH11
H
H
L
L
L
CH12
H
H
L
H
L
CH13
H
H
H
L
L
CH14
H
H
H
H
L
CH15
1/ Between (CH0-CH15) and OUTPUT1 (0-15)
TRUTH TABLE (CH16–CH31)
B3
B2
B1
B0
EN (16-31)
"ON" CHANNEL, 1/ (OUTPUT 2)
X
X
X
X
H
NONE
L
L
L
L
L
CH16
L
L
L
H
L
CH17
L
L
H
L
L
CH18
L
L
H
H
L
CH19
L
H
L
L
L
CH20
L
H
L
H
L
CH21
L
H
H
L
L
CH22
L
H
H
H
L
CH23
H
L
L
L
L
CH24
H
L
L
H
L
CH25
H
L
H
L
L
CH26
H
L
H
H
L
CH27
H
H
L
L
L
CH28
H
H
L
H
L
CH29
H
H
H
L
L
CH30
H
H
H
H
L
CH31
1/ Between (CH16-CH31) and OUTPUT2 (16-31)
SCD8522 Rev D 10/9/13
5
Aeroflex Plainview
Address Lines
(A0 - A3 / B0 - B3 )
4.0V
50%
0.8V
11.6V MIN
50%
MUX Output
0V
t AHL
Definition of t AHL
Address Lines
(A0 - A3 / B0 - B3 )
4.0V
50%
0.8V
11.6V MIN
MUX Output
50%
0V
t ALH
Definition of t ALH
4.0V
EN Lines
50%
0.8V
~3V to 10.0V
MUX Output
50%
0V
tONEN
tOFFEN
Definition of tONEN and tOFFEN
NOTE: f = 10KHz, Duty cycle = 50%.
MUX8522 SWITCHING DIAGRAMS
SCD8522 Rev D 10/9/13
6
Aeroflex Plainview
PIN NUMBERS & FUNCTIONS
MUX8522 – 56 Leads Ceramic QUAD Flat Pack
Pin #
Function
Pin #
Function
1
CH0
29
CH31
2
CH1
30
CH30
3
CH2
31
CH29
4
CH3
32
CH28
5
CH4
33
CH27
6
CH5
34
CH26
7
GND
35
GND
8
GND
36
GND
9
CH6
37
CH25
10
CH7
38
CH24
11
CASE GND
39
VREF
12
OUTPUT1 (0-15)
40
B3
13
EN (0-15)
41
B2
14
A0
42
B1
15
A1
43
B0
16
A2
44
EN (16-31)
17
A3
45
OUTPUT2 (16-31)
18
+VEE
46
-VEE
19
CH15
47
CH16
20
CH14
48
CH17
21
GND
49
GND
22
GND
50
GND
23
CH13
51
CH18
24
CH12
52
CH19
25
CH11
53
CH20
26
CH10
54
CH21
27
CH9
55
CH22
28
CH8
56
CH23
Notes:
1. It is recommended that all "NC" or "no connect pin", be grounded. This eliminates or minimizes any ESD or static buildup.
2. Package lid is internally connected to circuit ground (Pins 7, 8, 11, 21, 22, 35, 36, 49, 50).
SCD8522 Rev D 10/9/13
7
Aeroflex Plainview
ORDERING INFORMATION
Model
DLA SMD #
Screening
Package
MUX8522-7
-
Commercial Flow, +25°C testing only
MUX8522-S
-
Military Temperature, -55°C to +125°C
Screened in accordance with the individual Test Methods
of MIL-STD-883 for Space Applications
MUX8522-201-1S
5962-0923101KXC
In accordance with DLA SMD
MUX8522-901-1S
5962F0923101KXC
In accordance with DLA Certified RHA Program Plan to RHA
Level "F", 300krads(Si)
QUAD Flat
Pack
0.650 ±.005
(13 Spaces at .050)
Tol Non-Cum
4 Sides
PACKAGE OUTLINE
Pin 1
Pin 7
.200
MAX
Pin 50
Pin 49
Pin 8
.0165
±.003
0.800 SQ
±.010
Pin 21
(.650)
Pin 36
Pin 35
Note: Outside ceramic tie bars
not shown for clarity. Contact
factory for details.
Pin 22
.006
±.002
EXPORT CONTROL:
EXPORT WARNING:
This product is controlled for export under the International Traffic in
Arms Regulations (ITAR). A license from the U.S. Department of
State is required prior to the export of this product from the United
States.
Aeroflex’s military and space products are controlled for export under
the International Traffic in Arms Regulations (ITAR) and may not be
sold or proposed or offered for sale to certain countries. (See ITAR
126.1 for complete information.)
PLAINVIEW, NEW YORK
Toll Free: 800-THE-1553
Fax: 516-694-6715
INTERNATIONAL
Tel: 805-778-9229
Fax: 805-778-1980
NORTHEAST
Tel: 603-888-3975
Fax: 603-888-4585
SE AND MID-ATLANTIC
Tel: 321-951-4164
Fax: 321-951-4254
WEST COAST
Tel: 949-362-2260
Fax: 949-362-2266
CENTRAL
Tel: 719-594-8017
Fax: 719-594-8468
www.aeroflex.com
[email protected]
Aeroflex Microelectronic Solutions reserves the right to
change at any time without notice the specifications, design,
function, or form of its products described herein. All
parameters must be validated for each customer's application
by engineering. No liability is assumed as a result of use of
this product. No patent licenses are implied.
SCD8522 Rev D 10/9/13