Axial Lead & Cartridge Fuses 5×20 mm > Time-Lag > 218 Series 218 Series, PS E 5 x 20 mm, Time-Lag (Slo-Blo®) Fuse Description 5x20mm Time-Lag glass body cartridge fuse designed to IEC specification. Features t %FTJHOFEUP International (IEC ) Standards for use globally t "WBJMBCMFJODBSUSJEHF and axial lead form t .FFUTUIF*&$ 4IFFU t 3P)4DPNQMJBOUBOE lead-free specification for TimeLag fuses Agency Approvals Applications PS E Agency File Number Ampere Range Cartridge Certificates: NBK120802-E10480 A&C Leaded Certificates: NBK120802-E10480 B&D Certificates: 2005010207145715 Used as supplementary protection in appliance or VUJMJ[BUJPOFRVJQNFOUUPQSPWJEFJOEJWJEVBMQSPUFDUJPOGPS components or internal circuits. 1A – 5A 6.3A – 15A 32mA – 6.3A Electrical Characteristics Certificates: SU05001-3005 SU05001-2008 SU05001-2009 32mA – 40mA 50mA – 800mA 1A – 10A Recognised File: E10480 Guide: JDYX2 32mA – 16A File: 029862 Acc. Class: LR1422-30 File: 9850004, 9843043, 811742, 304650, 416270 License: 40013496 % of Ampere Rating 150% 210% 32mA – 15A 32mA – 6.3A 275% 32mA – 10A License: 40016604 15A* License: KM41462 80mA – 6.3A 400% 1000% 32mA – 16A Ampere Rating Opening Time 32mA–100mA 60 minutes, Minimum 125mA-6.3A 60 minutes, Minimum 8A-15A 30 minutes, Minimum 32mA-100mA 120 sec., Maximum 125mA-6.3A 120 sec., Maximum 8A-15A 120 sec., Maximum 32mA-100mA 200 ms., Min.; 10 sec. Max. 125mA-6.3A 600 ms., Min.; 10 sec. Max. 8A-15A 600 ms., Min.; 10 sec. Max. 32mA-100mA 40 ms., Min.; 3 sec. Max. 125mA-6.3A 150 ms., Min.; 3 sec. Max. 8A-15A 150 ms., Min.; 3 sec. Max. 32mA-100mA 10 ms., Min.; 300 ms. Max. 125mA-6.3A 20 ms., Min.; 300 ms. Max. 8A-15A 20 ms., Min.; 300 ms. Max. "QQSPWBMGPS$BSUSJEHFWFSTJPOTPOMZ © 2012 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to www.littelfuse.com/series/218.html for current information. 218 Series Revised: April 23, 2012 218 Series Agency Introduction to & Circuit Protection Axial Lead Cartridge Fuses Transientology 5×20 mm > Time-Lag > 218 Series Electrical Characteristics Voltage Rating (V) Nominal Cold Resistance (Ohms) Nominal Power Dissipation At Rated Current (W) Agency Approvals Amp Code .032 0.032 250 48.2580 0.01100 5000 1.6 x x x x x x x .040 0.04 250 31.8620 0.01100 4000 1.6 x x x x x x x Interrupting Rating Nominal Melting I2t (A2 sec) Nominal Voltage Drop at Rated Current (mV) Amp Rating (A) PS E .050 0.05 250 21.2920 0.01700 3500 1.6 x x x x x x x .063 0.063 250 14.2680 0.02800 3000 1.6 x x x x x x x .080 0.08 250 9.0700 0.07500 2500 1.6 x x x x x x x x .100 0.1 250 6.0180 0.07900 2000 1.6 x x x x x x x x .125 0.125 250 4.2000 0.1465 1900 1.6 x x x x x x x x .160 0.16 250 3.7000 0.14400 1500 1.6 x x x x x x x x .200 0.2 250 1.6000 0.3410 1300 1.6 x x x x x x x x x .250 0.25 250 .315 0.315 250 1.0495 0.5405 1100 1.6 x x x x x x x 0.8475 1.1100 1000 1.6 x x x x x x x .400 0.4 x 250 0.5350 1.3250 900 1.6 x x x x x x x x 35 A @ 250 VAC .500 0.5 250 0.3700 2.8250 300 1.6 x x x x x x x x .630 0.63 250 0.2750 4.6750 250 1.6 x x x x x x x x .800 0.8 250 0.0813 3.370 150 1.6 x x x x x x x x 001. 1 250 0.0613 6.730 150 1.6 x x x x x x x x x 1.25 1.25 250 0.0446 12.650 150 1.6 x x x x x x x x x 01.6 1.6 250 0.0336 23.350 150 1.6 x x x x x x x x x 002. 2 250 0.0293 14.450 150 1.6 x x x x x x x x x 02.5 2.5 250 0.0219 23.250 120 1.6 x x x x x x x x x 3.15 3.15 250 0.0173 38.150 100 1.6 x x x x x x x x x 004. 4 250 40 A @ 250 VAC 0.0129 69.10 100 1.6 x x x x x x x x x 005. 5 250 50 A @ 250 VAC 0.0104 111.00 100 1.6 x x x x x x x x x 06.3 6.3 250 63 A @ 250 VAC 0.0076 198.50 100 1.6 x x x x x x x x x 008. 8 250 80 A @ 250 VAC 0.0059 341.50 100 4 x x x x x x 010. 10 250 100 A @ 250 VAC 0.0045 568.00 100 4 x x x x x x 12.5 12.5 250 63 A @ 250 VAC 0.0034 889.00 100 4 x x 015. 15 250 100 A @ 250 VAC 0.0028 1405.00 100 4 x 016. 16 250 63 A @ 250 VAC 0.0021 1955.00 100 4 x x x x x x* x "QQSPWBMGPSDBSUJEHFWFSTJPOTPOMZ Average Time Current Curves 0.032A 0.040A 0.050A 0.063A 0.080A 0.100A 0.125A 0.160A 0.200A 0.250A 0.315A 0.400A 0.500A 0.630A 0.800A 1A 1.25A 1.6A 2A 2.5A 3.15A 4A 5A 6.3A 8A 10A 12.5A 15A 16A Temperature Rerating Curve 10000 1000 TIME IN SECONDS 100 10 1 0.1 0.01 0.01 0.1 1 10 100 CURRENT IN AMPERES 218 Series © 2012 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to www.littelfuse.com/series/218.html for current information. Axial Lead & Cartridge Fuses 5×20 mm > Time-Lag > 218 Series Soldering Parameters - Wave Soldering Recommended Process Parameters: 280 260 Wave Parameter 240 220 Lead-Free Recommendation 200 Preheat: 180 %FQFOETPO'MVY"DUJWBUJPO5FNQFSBUVSF Temperature Minimum: 160 140 120 100 80 60 40 (Typical Industry Recommendation) 100° C Temperature Maximum: 1SFIFBU5JNF 150° C 60-180 seconds Solder Pot Temperature: 260° C Maximum Solder Dwell Time: 2-5 seconds 240 230 220 210 200 190 180 170 160 150 140 130 120 110 90 100 80 70 60 50 40 30 0 0 20 20 10 Temperature (°C) - Measured on bottom side of board 300 Time (Seconds) Cooling Time Preheat Time Dwell Time Recommended Hand-Solder Parameters: 4PMEFS*SPO5FNQFSBUVSF¡$¡$ )FBUJOH5JNFTFDPOETNBY Note: These devices are not recommended for IR or Convection Reflow process. Material Body: Glass Cap: Nickel–plated Brass Leads: Tin–plated Copper Terminal Strength .*-45%(.FUIPE"5FTU Condition A Solderability Reference IEC 60127 Second Edition 2003-01 Annex A Product Marking Cap1: Brand logo, current and WPMUBHFSBUJOHT Cap2:"HFODZBQQSPWBMNBSLT Packaging "WBJMBCMFJO#VML.QDTQLH PSPO5BQF3FFM.3&5QDT reel) © 2012 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to www.littelfuse.com/series/218.html for current information. Operating Temperature –55ºC to +125ºC Thermal Shock .*-45%(.FUIPE(5FTU Condition B (5 cycles, –65°C to +125°C) Vibration .*-45%(.FUIPE" Humidity Salt Spray .*-45%(.FUIPE#5FTU $POEJUJPO")JHI3) BOE FMFWBUFEUFNQFSBUVSF°C) for 240 IPVST .*-45%(.FUIPE%5FTU Condition B 218 Series 218 Series Product Characteristics Introduction to & Circuit Protection Axial Lead Cartridge Fuses Transientology 5×20 mm > Time-Lag > 218 Series Dimensions Part Numbering System 0218 xxxx M X E P 20+0.5 5.2+0.1 -0.2 0218 000P 5.1+0.6 Series 5.1+0.6 Amp Code Refer to Amp Code column of Electrical Characteristics Table 0218.032 XEP to 0218.100XEP 40 22.5 MAX 6.0 MAX Quantity Code M = 1000 0.65 Packaging Code X = Filler 0218.125 XEP to 0218016. XEP 40 Option Codes 5.8 MAX 22.5 MAX Blank : Cartidge Type Fuse E : Axial Lead Fuse 0.65* Lead-free All dimensions in mm Notes: * Ratings above 6.3A have 0.8 mm dia lead Packaging Packaging Option 218 Series Bulk Bulk Reel and Tape Bulk Bulk Bulk 218 Series Packaging Specification Quantity Quantity & Packaging Code Taping Width /" /" EIA 296-E /" /" /" 1000 1000 1000 1000 1000 100 MX MXE MRET1 MXG MXB )9 /" /" 5NNw /" /" /" © 2012 Littelfuse, Inc. Specifications are subject to change without notice. Please refer to www.littelfuse.com/series/218.html for current information.