ACT4489 (05/05)

Standard Products
ACT4489 Single Transceiver
for MIL-STD-1553A/B, MIL-STD-1760 & SAE-AS15531
www.aeroflex.com/Avionics
May 16, 2005
FEATURES
❑
❑
❑
❑
❑
❑
❑
❑
Small size, light weight and low power dissipation single transceiver
Bipolar supply ±12V, logic supply +5V
Outstanding MIL-STD-1553 / SAE-AS15531 performance
Monolithic construction
Input and output TTL compatible design
Designed for commercial, industrial and aerospace applications
MIL-PRF-38534 compliant devices available
Aeroflex-Plainview is a Class H & K MIL-PRF-38534 manufacturer
DESCRIPTION
The Aeroflex-Plainview ACT4489 is the next generation monolithic transceiver design which provides full
compliance with MIL-STD-1553A/B, MIL-STD-1760 and meets SAE-AS15531 requirements in a small package
with low power consumption. The series performs the front-end analog function of inputting and outputting data
through a transformer to the MIL-STD-1553 data bus.
Design of these transceivers reflects particular attention to active filter performance. This results in low bit and word
error rate with superior waveform purity and minimal zero crossover distortion. Efficient transmitter electrical and
thermal design provides low internal power dissipation and heat rise at high as well as low duty cycles.
TRANSMITTER
The transmitter section accepts bi-phase TTL data at the input and when coupled to the data bus with a 1:1 ratio
transformer the data bus signal is typically 7.0 VP-P at Point A (See Figure 5). When both DATA and DATA inputs
are held low or high, the transmitter output becomes a high impedance and is “removed” from the line. In addition,
an overriding “INHIBIT input provides for the removal of the transmitter output from the line. A logic “1” applied to
the “INHIBIT” takes priority over the condition of the data inputs and disables the transmitter (See Figure 1
Transmitter Logic Waveform). The Transmitter may be safely operated for an indefinite period with the bus (Point
A) short circuited at 100% duty cycle.
RECEIVER
The Receiver section accepts bi-phase differential data at the input and produces two TTL signals at the output. The
outputs are DATA and DATA, and represent positive and negative excursions of the input beyond a pre-determined
threshold (See Figure 2 Receiver Logic Waveform).
The pre-set internal thresholds will detect data bus signals exceeding 1.20 VP-P and reject signals less than 0.6 VP-P
when used with a transformer (See Figure 5 for transformer data and typical connections).
A low level at the RX STROBE IN input inhibits the DATA and DATA outputs.
SCD4489 Rev B
TX DATA IN
TX DATA OUT
DRIVER
TX DATA IN
ACTIVE
FILTER
OUTPUT
STAGE
TX DATA OUT
REFERENCE
COMP.
RX DATA OUT
ACTIVE
FILTER
COMP.
TX INHIBIT
+5 V (VL)
+12 V (+Vcc)
-12 V (-VEE)
GND1-3
CASE
RX DATA IN
RX DATA IN
INPUT
AMPLIFIER
RX DATA OUT
RX STROBE
BLOCK DIAGRAM (WITHOUT TRANSFORMER)
DATA IN
DATA IN
INHIBIT
LINE TO LINE
OUTPUT
Note: DATA and DATA inputs must be complementary waveforms or 50% duty cycle average, with no delays between them,
and must be in the same state during off times (both high or low).
FIGURE 1 – TRANSMITTER LOGIC WAVEFORMS IDEALIZED
LINE TO LINE
INPUT
STROBE
DATA OUT
DATA OUT
Note overlap
FIGURE 2 – RECEIVER LOGIC WAVEFORMS IDEALIZED
SCD4489 Rev B
2
ABSOLUTE MAXIMUM RATINGS
Operating case temperature
-55°C to +125°C
Storage case temperature
-65°C to +150°C
Power supply voltage
VCC
VEE
VL
-0.3 VDC to +18 VDC
+0.3 VDC to -18 VDC
-0.3 VDC to +7.0 VDC
Logic input voltage
-0.3VDC to +5.5VDC
Receiver differential input
±40 Vp-p
Receiver input voltage (common mode)
±10V
Driver peak output current
300 mA
Total package power dissipation over the full operating
case temperature range
2.5 Watts
Maximum junction to case temperature
10°C
Thermal resistance – Junction to case
4°C/W
ELECTRICAL CHARACTERISTICS – DRIVER SECTION (Note 2)
INPUT CHARACTERISTICS, TX DATA IN OR TX DATA IN
Parameter
Conditions
Symbol
Min
Typ
Max
Unit
"0" Input Current
VIN = 0.4V
IILD
-
-0.1
-0.2
mA
"1" Input Current
VIN = 2.7V
IIHD
-
1
40
µA
"0" Input Voltage
VILD
-
-
0.7
V
"1" Input Voltage
VIHD
2.0
-
-
V
INHIBIT CHARACTERISTICS
"0" Input Current
VIN = 0.4V
IILI
-
-0.1
-0.2
mA
"1" Input Current
VIN = 2.7V
IIHI
-
1.0
40
µA
"0" Input Voltage
VILI
-
-
0.7
V
"1" Input Voltage
VIHI
2
-
-
V
Delay from TX inhibit, (0➝1) to inhibited output
tDXOFF
-
175
225
nS
Delay from TX inhibit, (1➝0) to active output
tDXON
-
90
150
nS
Differential Output Noise, inhibit mode
VNOI
-
2
10
mVP-P
Point B
ZOI
2K
-
-
Ω
Point C
ZOI
1K
-
-
Ω
Figure 5
Point A
VO
6
7
9
V P- P
tR & tF
100
160
300
nS
Output offset. See Figure 3. 2.5 µS after midpoint
crossing of the parity bit of the last word of a 660µS
message.
VOS
-
-
±90
mVpeak
Delay from 50% point of TX DATA or TX DATA
input to zero crossing of differential signal
tDTX
-
100
200
nS
Differential Output Impedance (inhibited) Note 1
See Figure 5
OUTPUT CHARACTERISTICS
Differential output level
Rise and fall times (10% to 90% of p-p output)
SCD4489 Rev B
3
ELECTRICAL CHARACTERISTICS – RECEIVER SECTION (Note 2)
Parameter
Differential Voltage Range
(See Figure 5, Point B)
Conditions
Symbol
Min
Typ
Max
Unit
TXFMR
1:1
VIDR
-
-
40
VPK
CMRR
45
-
-
dB
Common Mode Rejection Ratio (Note 3)
"1" State – Rx Data or Rx Data Output
IOH = -0.4 mA
VOH
2.5
3.7
-
V
"0" State – Rx Data or Rx Data Output
IOI = 4 mA
VOL
-
0.35
0.5
V
tDRX
-
270
400
nS
VTH
0.60
0.75
1.20
VP-P
Delay (average) from Differential Input Zero
Crossings to RX DATA and RX DATA Output 50%
points
Input Threshold Voltage (referred to the bus)
100KHz–1MHz
STROBE CHARACTERISTICS (LOGIC "0" INHIBITS OUTPUT)
"0" Input Current
VS = 0.4V
IIL
-
-0.1
-0.2
mA
"1" Input Current
VS = 2.7V
IIH
-
1
+40
µA
"0" Input Voltage
VIL
-
-
0.7
V
"1" Input Voltage
VIH
2.0
-
-
V
Strobe Delay (Turn-on or Turn-off)
tSD
-
50
100
nS
POWER DATA (Note 2)
POWER SUPPLY CURRENTS – PER CHANNEL – SEE FIGURE 4
Transmitter Standby
Note 4
ICC
IEE
IL
-
0
12
18
1
16
30
25% Duty Cycle
ICC
IEE
IL
-
58
12
18
63
20
30
50% Duty Cycle
ICC
IEE
IL
-
115
12
18
125
20
30
100% Duty Cycle
ICC
IEE
IL
-
230
12
18
250
20
30
mA
POWER SUPPLY VOLTAGE
±12V Operating Power Supply Voltage Range
VCC
VEE
+11.40
-11.40
+12.00 +12.60
-12.00 -12.60
V
V
+5V Operating Power Supply Voltage Range
VL
+4.50
+5.00
V
+5.50
Notes:
1. Power on or off, measured from 75KHz to 1MHz at point A and transformer self impedance of 3KΩ minimum at 1MHz.
2. Power Supplies: +12VDC ±0.60V & +5VDC ±0.5V, bypassed by 10 µF (Tantalum recommended) Capacitor minimum. All measurements
& specifications apply over the temperature range of -55°C to +125°C (Case temperature) unless otherwise specified.
3. When measured as shown per Figure 5 with ± 10VPK, line to ground, DC to 2MHz
4. Typical power is measured with VBUS at point A = 7.0VP-P
SCD4489 Rev B
4
LAST BIT
Magnified View
OUTPUT OFFSET
*
OUTPUT OFFSET
*
0 Volts
Transformer Coupled Stub
2.5 µsec
70Ω
ACT4489D
TX DATA OUT
*Offset measured at Point A in Figure 5
2
FIGURE 3 – TRANSMITTER (TX) OUTPUT
OFFSET
TX DATA OUT
1:1.4 52.5Ω
1:0.707
7
3
C
A
1
5
T1553-1
52.5Ω
RX DATA IN
Zoi
VCM
RX DATA IN
Direct Coupled Stub
ACT4489D
3600
TX DATA OUT
3200
2
POWER DISSIPATION
MILLIWATTS
3.0W
0.270W
2800
2400
Typical Hybrid Input Power
TX DATA OUT
2000
1.9W
RX DATA IN
1600
B
A
4
1
T1553-1
55Ω
Zoi
RX DATA IN
1200
800
Typical Hybrid
Dissipation
400
0
0
55Ω
1:1
3
8
10
20
30
40
50
60
70
80
Transformer Model use Technitrol Part# 1553-1
or equivalent
90 100
FIGURE 5 – TYPICAL 1553 BUS
CONNECTIONS
DUTY CYCLE – PERCENT
Note: Vcc = +12VDC, VEE = -12VDC, VL = +5VDC, Transformer ratio 1:1,
VBUS (Point A) at 7.0VP-P.
FIGURE 4 – POWER DISSIPATION VS.
DUTY CYCLE
SCD4489 Rev B
5
70Ω
PIN NUMBERS & FUNCTIONS
Pin #
Function
Pin #
Function
1
TX DATA OUT
13
VCC
2
TX DATA OUT
14
NC
3
GROUND
15
RX DATA IN
4
NC
16
RX DATA IN
5
NC
17
NC
6
NC
18
CASE
7
RX DATA OUT
19
VEE
8
STROBE
20
VL
9
GROUND
21
TX INHIBIT
10
RX DATA OUT
22
TX DATA IN
11
NC
23
TX DATA IN
12
NC
24
NC
PACKAGE CONFIGURATION OUTLINES
Plug In Package Outline
1.385 MAX.
24
13
0.805
MAX.
0.600
Pin 1 & ESD
Designator
12
0.200
MAX.
.240
MIN.
.015
.018
.100
1.100
(11 Equal Spaces at .100)
Flat Package Outline
.200
MAX.
.065
1.315 MAX.
.015
24
13
0.735
MAX.
Lead 1 & ESD
Designator
12
.375
MIN.
.100
.010
1.100
(11 Equal Spaces at .100)
SCD4489 Rev B
6
CONFIGURATIONS AND ORDERING INFORMATION
Model No.
Receiver Data level
ACT 4489
Normally Low
ACT 4489-I
Normally High
ACT 4489-F
Normally Low
ACT 4489-FI
Normally High
PLAINVIEW, NEW YORK
Toll Free: 800-THE-1553
Fax: 516-694-6715
INTERNATIONAL
Tel: 805-778-9229
Fax: 805-778-1980
NORTHEAST
Tel: 603-888-3975
Fax: 603-888-4585
SE AND MID-ATLANTIC
Tel: 321-951-4164
Fax: 321-951-4254
WEST COAST
Tel: 949-362-2260
Fax: 949-362-2266
CENTRAL
Tel: 719-594-8017
Fax: 719-594-8468
www.aeroflex.com
Case
Plug In
Flat Package
[email protected]
Aeroflex Microelectronic Solutions reserves the right to
change at any time without notice the specifications, design,
function, or form of its products described herein. All
parameters must be validated for each customer's application
by engineering. No liability is assumed as a result of use of
this product. No patent licenses are implied.
Our passion for performance is defined by three
attributes represented by these three icons:
solution-minded, performance-driven and customer-focused
SCD4489 Rev B
7