For more information, please visit the product page. date 06/10/2015 page 1 of 6 SERIES: VSK-S15-T │ DESCRIPTION: AC-DC POWER SUPPLY FEATURES • • • • • • • up to 15W continuous power compact chassis mount design universal input (85~264 Vac / 100~370 Vdc) single output from 3.3~48 Vdc over voltage, over current, and short circuit protections UL/cUL safety approvals efficiency up to 85% MODEL output voltage output current output power ripple and noise1 efficiency (Vdc) max (A) max (W) typ (mVp-p) typ (%) 3.3 3 9.9 50 73 VSK-S15-5U-T 5 2.8 14 50 76 VSK-S15-9U-T 9 1.6 14.4 50 78 VSK-S15-12U-T 12 1.25 15 50 80 VSK-S15-15U-T 15 1.0 15 50 80 VSK-S15-24U-T 24 0.625 15 50 84 VSK-S15-48U-T 48 0.32 15 50 85 VSK-S15-3R3U-T Notes: 1. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 uF ceramic and 10 uF electrolytic capacitors on the output. PART NUMBER KEY VSK-S15 - XXU - T Base Number Output Voltage cui.com For more information, please visit the product page. CUI Inc │ SERIES: VSK-S15-T │ DESCRIPTION: AC-DC POWER SUPPLY date 06/10/2015 │ page 2 of 6 INPUT parameter conditions/description min voltage frequency max units 85 100 typ 264 370 Vac Vdc 47 63 Hz 370 220 mA mA current at 115 Vac at 230 Vac inrush current at 115 Vac at 230 Vac 10 20 A A leakage current at 230 Vac, 50 Hz (RMS) 0.1 mA input fuse 2 A/250 V, slow-blow type (included on chassis) OUTPUT parameter conditions/description capacitive load 3.3 Vdc output model 5 Vdc output model 9 Vdc output model 12 Vdc output model 15 Vdc output model 24 Vdc output model 48 Vdc output model line regulation at full load load regulation at 10~100% load min voltage set accuracy hold-up time at 115 Vac at 230 Vac switching frequency temperature coefficient typ max units 36,000 20,000 6,000 3,000 3,000 900 370 μF μF μF μF μF μF μF ±0.5 % ±1 % ±2 % 15 80 ms ms 65 kHz ±0.02 %/°C PROTECTIONS parameter conditions/description min over current protection auto restart 110 short circuit protection continuous, auto restart over voltage protection 3.3 Vdc output model 5 Vdc output model 9 Vdc output model 12 Vdc output model 15 Vdc output model 24 Vdc output model 48 Vdc output model typ max units % 7.5 7.5 12 20 20 30 60 Vdc Vdc Vdc Vdc Vdc Vdc Vdc max units SAFETY & COMPLIANCE parameter conditions/description isolation voltage input to output for 1 minute safety approvals UL60950-1, CE safety class class II conducted emissions CISPR22/EN55022, Class B radiated emissions CISPR22/EN55022, Class B ESD IEC/EN61000-4-2 Class B, contact ±6 kV/air ±8 kV radiated immunity IEC/EN61000-4-3 Class A, 10V/m EFT/burst min typ 3,000 IEC/EN61000-4-4 Class B, ±2 kV IEC/EN61000-4-4 Class B, ±4 kV (external circuit required, see figure 2) cui.com Vac For more information, please visit the product page. CUI Inc │ SERIES: VSK-S15-T │ DESCRIPTION: AC-DC POWER SUPPLY date 06/10/2015 │ page 3 of 6 SAFETY & COMPLIANCE (CONTINUED) parameter conditions/description surge IEC/EN61000-4-5 Class B, ±1 kV/±2 kV IEC/EN61000-4-5 Class B, ±2 kV/±4 kV (external circuit required, see figure 2) min typ max conducted immunity IEC/EN61000-4-6 Class A, 10 Vr.m.s PFM IEC/EN61000-4-8 Class A, 10 A/m voltage dips & interruptions IEC/EN61000-4-11 Class B, 0%-70% MTBF as per MIL-HDBK-217F at 25°C RoHS 2011/65/EU units 300,000 hrs ENVIRONMENTAL parameter conditions/description min operating temperature see derating curves storage temperature storage humidity typ max units -40 70 °C -40 105 °C 95 % non-condensing DERATING CURVES Safe operating area 40 75 60 Safe operating area 40 20 -10 -5 5 Safe operating area 40 20 25 35 45 Ambient Temperature (°C) 55 65 70 75 85 95 100 105 115 125 235 240 245 Input Voltage (Vac) cui.com 255 264 ~ ~ -40 75 60 ~ ~ 20 100 Load (%) Load (%) 60 load vs. input voltage (Vdc) (at 25°C) ~ ~ ~ ~ 100 80 ~ ~ Load (%) 100 load vs. input voltage (Vac) (at 25°C) ~ ~ load vs. ambient temperature (at 100~240 Vac) 100 120 340 Input Voltage (Vdc) 370 For more information, please visit the product page. CUI Inc │ SERIES: VSK-S15-T │ DESCRIPTION: AC-DC POWER SUPPLY date 06/10/2015 │ page 4 of 6 MECHANICAL parameter conditions/description dimensions 96.10 x 54.00 x 31.00 (3.783 x 2.126 x 1.22 inch) min case material UL94V-0 typ units mm weight 135 cooling max g convection cooling MECHANICAL DRAWING units: mm[inches] tolerance: ±0.50[±0.020] >@ >@ >@ PIN CONNECTIONS FUNCTION 1 NC 2 AC(N) 3 AC(L) 4 -Vo 5 NC 6 NC 7 NC 8 +Vo Top View >@ PIN >@ >@ wire range: 24~12 AWG >@ >@ Side View cui.com For more information, please visit the product page. CUI Inc │ SERIES: VSK-S15-T │ DESCRIPTION: AC-DC POWER SUPPLY date 06/10/2015 │ page 5 of 6 TYPICAL APPLICATION CIRCUIT Figure 1 FU S E AC(L) AC(L) C1 +Vo T VS 1 C2 AC / DC M OV 1 LOAD AC(N) AC(N) -Vo Table 1 Recommended External Circuit Components Note: MODEL FUSE1 MOV1 C1 C2 TVS VSK-S15-3R3U-T 2A/250V S14K350 1µF 680μF SMBJ7.0A VSK-S15-5U-T 2A/250V S14K350 1µF 680μF SMBJ7.0A VSK-S15-9U-T 2A/250V S14K350 1µF 470μF SMBJ12A VSK-S15-12U-T 2A/250V S14K350 1µF 220μF SMBJ20A VSK-S15-15U-T 2A/250V S14K350 1µF 220μF SMBJ20A VSK-S15-24U-T 2A/250V S14K350 1μF 68μF SMBJ30A VSK-S15-48U-T 2A/250V S14K350 1µF 33μF SMBJ64A 1. Fuse included on chassis EMC RECOMMENDED CIRCUIT Figure 2 FUSE LDM LCM AC(L) AC( L) +Vo CY1 MOV1 C1 C2 TVS1 RL + ACDC CX CY2 -Vo AC(N) AC(N) Table 2 Recommended External Circuit Components Note: MOV1 S14K350 CY1, CY2 1000pF/400Vac CX 0.1μF/275Vac LCM 10mH LDM 4.7μH/2A Also refer to Table 1 Notes: 1. Output filtering capacitor C2 is an electrolytic capacitor, It is recommended to use high frequency and low impedance electrolytic capacitors. For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be 80% or above. C1 is used to filter high frequency noise. TVS is recommended component to protect post-circuits (when converter fails). 2. All specifications measured at Ta=25C, humidity <75%, nominal input voltage, and rated output load, unless otherwise specified. cui.com For more information, please visit the product page. CUI Inc │ SERIES: VSK-S15-T │ DESCRIPTION: AC-DC POWER SUPPLY date 06/10/2015 │ page 6 of 6 REVISION HISTORY rev. description date 1.0 initial release 09/06/2012 1.01 corrected pinout 10/21/2013 1.02 updated spec 08/20/2014 updated operating and storage temperatures 06/10/2015 1.03 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.