Datenblatt

For more information, please visit the product page.
date
04/23/2012
page
1 of 3
MODEL: GC0351P │ DESCRIPTION: SPEAKER
FEATURES
• plastic frame
• slim profile
• S.P. level 80 dB
RoHS
SPECIFICATIONS
parameter
conditions/description
min
typ
max
nominal size
16 x 35
impedance
at 1.2 kHz, 1 V
6.8
8
9.2
resonant frequency
at 1 V
440
550
660
Hz
sound pressure level
1 W, 50 cm ave., at 0.6, 0.8, 1, 1.2 kHz
77
80
83
dB
response
10 dB max.
Fo
13,000
Hz
2
W
mm
input power
operation
units
1
must be normal at program source
Ω
1
W
2.83
Vdc
buzz, rattle, etc.
must be normal at sine wave
magnet
size: 8.0 x 2.0 mm
load test
24 hours of white noise at
heat test
20 ~ 50% RH for 24 hours
63
65
67
°C
humidity test
90 ~ 95% RH for 24 hours
38
40
42
°C
RoHS
yes
1
FREQUENCY RESPONSE CURVE
parameter
conditions/description
potentiometer range
50 dB
rectifier
RMS
lower limit frequency
20 Hz
wr. speed
100 mm/sec
zero level
50 dB
cui.com
W
For more information, please visit the product page.
CUI Inc │ MODEL: GC0351P │ DESCRIPTION: SPEAKER
date 04/23/2012 │ page 2 of 3
MECHANICAL DRAWING
units: mm
tolerance: ±0.5mm unless otherwise specified
11.2
8.0
0.3
6.2
2.3
4.5
31.0 (TYP)
0.2
16.0
0.2
5.0
35.0
0.2
12.0 (TYP)
0.2
2.1
(4 PLCS)
1.0mm GAP
REQUIRED
FOR CONE
OPERATION
cui.com
For more information, please visit the product page.
CUI Inc │ MODEL: GC0351P │ DESCRIPTION: SPEAKER
date 04/23/2012 │ page 3 of 3
REVISION HISTORY
rev.
description
date
1.0
initial release
06/04/2007
1.01
new template applied, updated sound pressure level
04/23/2012
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.