Test Procedure for the NCL30083FLYGEVB Evaluation Board
Equipment Needed





AC Source – 100 to 265 V ac 50/60 Hz Minimum 1 A ac capabilities
AC Wattmeter – 30 W Minimum, True RMS Input Voltage and Current, Power Factor
0.2% accuracy or better
DC Voltmeter – 100 V dc minimum 0.1% accuracy or better
DC Ammeter – 1 A dc minimum 0.1% accuracy or better
LED Load
o Flyback – 14 – 17 V dc – 5 LED Load @ 500 mA
o Buck Boost – 50 – 55 V dc – 15 LED Load @ 200 mA
Test Connections
1.
Connect the Unit Under Test (UUT) per the test set up in Figure below.
AC Power
Source
AC
Wattmeter
UUT
DC
Ammeter
DC
Voltmeter
LED Test
Load
Figure: Test Set Up
2. Set the AC source to 120 ±1 V ac RMS 60 Hz or 230 ±2 V ac RMS 50 Hz.
Note: Unless otherwise specified, all voltage measurements are taken at the terminals of
the UUT.
Functional Test Procedure
Flyback Version (NCL30083FLYGEVB)
Test Condition
Test Variable
Vin = 100 V ac
Vin = 120 V ac
Vin = 265 V ac
Vin = 265 V ac
Vin = 120 V ac
Vout = 14 V
Output Current
Output Current
Output Current
Power Factor
Efficiency =
6/1/2013
Efficiency (use actual
measured data)
Test Limits
Min
Max
490 mA
490 mA
490 mA
0.70
82 %
Pass/Fail
510 mA
510 mA
510 mA
× 100%
1
www.onsemi.com
Step Dimming Test Procedure NCL30083BB1GEVB/NCL30083FLYGEVB
1. Connect the UUT to the LED load.
2. Apply 120 V ac power.
3. Verify that the output current is within the regulation limits as specified in the functional
test procedure.
4. Interrupting the AC input for 1-2 s will step the output current down.
5. There 6 discrete current levels. After the lowest level, the current will return to
maximum output.
6. Cycle the input power 6 times validating that the current steps down at each cycle and
returns to maximum.
6/1/2013
2