Test Procedure for the NC30160GEVB 03/7/2012 Agilent E3632A DC Power Supply Chroma 63106 Chroma 6312 + - Agilent 34401A Multimeter HI HI LO + LO I 05/15/2012 1 www.onsemi.com Table 1: Required Equipment Agilent E3632A DC Power Agilent 34401A Multimeter Supply Two Black Test Leads Chroma 6312 Electronic Load Mainframe One NCL30160GEVB Evaluation Board Three Red Test Leads Chroma 63106 Electronic Load Test Procedure: 1. Connect the test setup as shown above. 2. Apply an input voltage, VIN = 12V across VIN and GND. 3. Apply 10 Ω loading from the electronic load after powering up the demo board. 4. Check IOUT. 5. Change the VIN voltage to VIN = 24V. 6. Check IOUT. 05/15/2012 2 www.onsemi.com Table 2: Desired Results For VIN = 12V, IOUT = 280 mA For VIN = 24V, IOUT = 277 mA 05/15/2012 3 www.onsemi.com