NCP1216LEDGEVB_TEST_PROCEDURE.PDF - 147.0 KB

Test Procedure for the NCP1216 Buck Led Board
LedA
AC1
V1
169.71V
120.00V_rms
60Hz
0Deg
A
Led1
High_Brightness_Led
AC2
Led2
High_Brightness_Led
LedK
Led3
High_Brightness_Led
Led4
High_Brightness_Led
Necessary Equipment:
Test Procedure:
Isolated Variable AC supply
DC Amp meter
Six 3W Leds
Output current can be reduced
by removing some of the 5.1ohm
parallel resistors (R1-R5)
1.
2.
3.
4.
5.
6.
7.
Connect test setup as shown
Apply input voltage 120Vac
Supply current ~ 150ma
Check that Leds light
Current in Led String ~650ma
Power down the input voltage
End of test
Led5
High_Brightness_Led
Led6
High_Brightness_Led
12/13/2007