NCP161FCT2GEVB_TEST_PROCEDURE.pdf - 268 KB

Test Procedure for the NCP161FCT2GEVB Evaluation Board
There is a collection test procedures for NCP160 demoboards. This paper offers some helpful
test configuration for first contact with ONSEMI NCP160 LDO.
1. QUIESCENT CURRENT
Vout_nom+1V or 2.5V
DC
Supply
-
+
μA
Figure 1: Test configuration for measurement IQ, Quiescent Current
1. Connect circuit as shown figure on 1
2. Apply voltage at VInput. Default test Vinput is Vout_nom+1 V or 2.5 V whichever is
greater
3. Value shown μA meter is measured quiescent current.
4. Measurement is finished. Disconnect supply voltage.
*Note – Be carefully if any device is connected on output, because leakage current can
affect measurement accuracy.
11/07/14
1
www.onsemi.com
2. LOAD REGULATION
Vout_nom+1V or 2.5V
DC
Supply
-
Electronic
load
+
+
-
V
IOUT
250 mA
1 mA
A
Figure 2: Test configuration for measurement REGLOAD, Load Regulation
1. Connect circuit as shown figure on 2
2. Apply voltage at VInput. Default test Vinput is Vout_nom+1 V or 2.5 V whichever is
greater
3. Set minimal required current I1, e.g. 1 mA, and switch load ON.
4. Note the value V1 from voltmeter Vo.
5. Switch load OFF and set maximal required current I2, e.g. 250 mA and switch load
ON.
6. Note the value V2 from voltmeter Vo.
7. Load regulation is obtained via following formula: REGLOAD=(V1-V2), [V]
8. Measurement is finished. Disconnect supply voltage.
11/07/14
2
www.onsemi.com
3. LINE REGULATION
VOUT_NOM+1.5V
VOUT_NOM+0.5V
DC
Supply
-
Electronic
load
+
+
-
V
VI
O
IOUT=10mA
Figure 3: Test configuration for measurement REGLINE, Line Regulation
Connect circuit as shown on figure 3
Set load to the required current e.g. 10 mA
Set minimal input voltage VI1, VOUT_NOM+1V or 2.5V whichever is greater
Note the value VI1 and VO1.
Set maximal input voltage VI2 = 5.5 V
Note the value VI2 and VO2.
Load regulation is obtained via following formula: REGLINE=(VO1-VO2)/(VI1-VI2),
[V/V]
8. Measurement is finished. Disconnect supply voltage.
1.
2.
3.
4.
5.
6.
7.
11/07/14
3
www.onsemi.com
4. ENABLE START-UP
OSCILOSCOPE
~
Vout_nom+1V or 2.5V
DC +
Supply -
Electronic
load
+
-
GENERATOR
IOUT=10mA
Figure 4: Test configuration for measurement enables response
1. Connect circuit as shown on figure 4
2. Set generator to SQUARE PULSE, 0.9 ≤ AMPLITUDE ≤ VIN, FREQUENCY=10Hz,
DUTY=10%
3. Apply voltage at VInput. Default test Vinput is Vout_nom+1 V or 2.5 V whichever is
greater
4. Set required IOUT, e.g. 10 mA
5. Connect oscilloscope to EN signal and VOUTPUT.
6. Watch enable response of the regulator after asserting EN pin.
7. Measurement is finished. Disconnect supply voltage.
11/07/14
4